首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Indirect and capture enzyme-linked immunosorbent assays (ELISAs) for detection of Hantaan virus (HTNV)-specific immunoglobulins G (IgG) and M (IgM) in human serum samples were developed on the basis of recombinant yeast-expressed nucleocapsid (N) protein of HTNV. The sensitivities and specificities of the indirect and capture ELISAs were evaluated by comparing the reactivity of sera from patients with hemorrhagic fever with renal syndrome (HFRS) from China with that of a commercial IgG/IgM kit. The sensitivity of the indirect IgG and IgM ELISA tests was both 100% and the specificity of the indirect IgM and IgG ELISA test was 98% and 99%, respectively. The sensitivity and specificity of the capture IgM ELISA was 100% and 97%, respectively. The novel assays were found to detect HTNV-specific antibodies in acute phase sera from suspected HFRS patients in China. The results indicate that these novel ELISAs are suitable for the diagnosis of HTNV and for sero-epidemiological studies.  相似文献   

2.
Accurate serological confirmation of dengue (DEN) infection is difficult, because simple reliable assays for the detection of DEN antibodies are not available. To address this problem, a dipstick enzyme-linked immunosorbent assay (ELISA) was evaluated. The dipstick contained dots of serially diluted DEN 2 antigen. To detect immunoglobulin G (IgG), the dipstick was processed through four reaction cuvettes containing test serum, enhancer, enzyme-conjugated anti-human IgG and IgM antibody, and substrate. Total assay time was 45 min. To detect IgM, the serum was passed through a protein G device to remove IgG. The dipstick was then processed as before, except that the incubation times were longer and enzyme-conjugated anti-human IgM was used. The total assay time was 3 h. The dipstick ELISA results were compared with results from microplate ELISA. The IgG dipstick ELISA showed a sensitivity of 95.2% and a specificity of 100% compared to an IgG microplate ELISA with serum samples from 125 individuals living in an area in which DEN is endemic. In tests with 75 serum samples from patients with clinically suspected acute DEN infections, the IgM dipstick ELISA showed a sensitivity of 97.9% and specificity of 100% compared to those of an IgM antibody capture microplate ELISA. These results showed that the dipstick ELISA was a sensitive and specific test for the detection of either DEN IgM or IgG in human serum. The dipstick ELISA was also shown to be useful for detecting seroconversions to DEN IgM or IgG in paired serum samples from 20 patients with virus isolation-confirmed acute DEN infections.  相似文献   

3.
Focus Technologies developed an indirect immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) and a mu-capture IgM ELISA for the detection of West Nile virus (WNV)-specific antibodies based on a WNV preM/E protein recombinant antigen. Normal and disease state serum panels were used to assess the performance characteristics of the two WNV ELISA kits. Totals of 807 and 1,423 sera were used to assess the IgG ELISA and IgM ELISA kits, respectively. The Focus Technologies IgG ELISA had a sensitivity of 97.6% and a specificity of 92.1% (excluding non-WNV flavivirus sera). The comparative method for WNV IgG may lack sensitivity in detecting IgG in early WNV infection, so the specificity of the Focus IgG ELISA may be higher than 92.1%. When sera from patients either infected with or vaccinated against other flaviviruses were tested on the WNV IgG assay, 35% of the sera reacted as positive for WNV IgG. Yellow fever and Japanese encephalitis vaccinees were less reactive in the IgG ELISA than St. Louis and dengue fever patients. The Focus Technologies IgM ELISA had a sensitivity and a specificity of 99.3% (excluding the non-WNV flavivirus sera). The overall cross-reactivity for the IgM ELISA to flavivirus sera was 12%, with 31% of St. Louis encephalitis patients found to be WNV IgM positive and no yellow fever vaccinees found to be WNV IgM positive. In a selected population of 706 sera, 15 false-positive WNV IgM sera were identified. The use of a background subtraction method for the IgM ELISA eliminated all 15 false-positive results, giving a specificity of 100% for the Focus IgM ELISA.  相似文献   

4.
Novel tests (BioPlex) for herpes simplex virus-1 (HSV-1) and HSV-2 IgG were compared with HerpeSelect HSV-1 and HSV-2 ELISAs for type-specific IgG. The sensitivity and specificity of BioPlex HSV-1 IgG were 94% (84/89) and 96% (119/124), respectively, with unselected sera, while the sensitivity and specificity of BioPlex HSV-2 IgG were 92% (109/118) and 98% (95/97), respectively. BioPlex IgM was compared with Diamedix IgM against sera from patients with culture-documented genital herpes. The test results were concordant in 81% of sera from HSV-1 patients and in 90% of sera from HSV-2 patients. Use of BioPlex IgM in addition to BioPlex IgG tests increased HSV-2 seroconversion detection from 47% of subjects to 70%. Use of Diamedix IgM in addition to Focus IgG ELISA increased HSV-2 detection from 40% of subjects to 70%. IgM was detected by BioPlex in 63% of sera from patients with early HSV-2 infection (< 30 days) and in 59% of sera by Diamedix. IgM was also detected in a large proportion of sera from subjects with established HSV-2 infection (33% by BioPlex and 29% by Diamedix). Addition of IgM testing substantially increased the ability to detect seroconversion early in infection. IgM is an indicator of recent infection only in subjects who lack detectable IgG.  相似文献   

5.
Antibodies against Mycoplasma pneumoniae in the sera of patients and normal adult controls were measured by a standard complement fixation (CF) test, a commercial immunofluorescence (IF) test (CROWNTITRE), and a commercial enzyme-linked immunosorbent assay (ELISA) (MYCOPLASMELISA). The findings showed that, in the control sera, 269 of 277 (97%) had negative results for CF antibodies. Of the 320 controls tested by the IF assay, all (100%) had negative results for IgM antibodies and 314 (98%) had negative results for IgG antibodies. Only 6 of the 201 (3%) controls by the ELISA were classified as negative/equivocal. Among the 450 patient sera, 105 (23%) had positive results for CF antibodies, and 158 (35%) had positive results for IgG and/or IgM membrane antibodies by the IF test; 424 of these patients' sera were also tested by the ELISA, and 397 (94%) of them were found to have positive results for anti-M. pneumoniae IgG antibodies. If the CF test were chosen as the standard for comparison, the IF test would have a sensitivity of 87% and a specificity of 81% and the ELISA would have a sensitivity of 71% and a specificity of 80%, provided an adjustment in the threshold ELISA-positive value was made. A single positive M. pneumoniae membrane IgM antibody titer appeared to be valuable for a presumptive diagnosis of an ongoing infection; 41 of 47 (87%) of the IgM-positive results in the paired sera were supported by a fourfold increase or a stable high level of CF antibody titer.  相似文献   

6.
Recombinant protein 44, expressed and purified as a maltose-binding protein fusion peptide of the human granulocytic ehrlichiosis (HGE) agent (Ehrlichia phagocytophila genogroup), was used as antigen in enzyme-linked immunosorbent assays (ELISAs) to detect total antibodies, immunoglobulin (Ig) M antibodies, and IgG antibodies. Of the 67 human sera obtained from 64 HGE patients 3-5 weeks after the onset of illness and confirmed as having total immunoglobulins to whole-cell antigen by indirect fluorescent antibody analyses, 63 were positive in a polyvalent ELISA. Fifty-six and 61 sera had IgM or IgG antibodies, respectively. Fifty sera had both IgM and IgG antibodies. In specificity tests of 110 sera, one serum sample from a patient who had Lyme borreliosis reacted to the protein 44 antigen in the analysis for IgM antibody (specificity, 99%). There were no false-positive results in an ELISA for IgG antibodies. With their high sensitivity and specificity, class-specific ELISAs can be used in conjunction with indirect fluorescent antibody analyses or immunoblotting methods to help diagnose human granulocytic ehrlichiosis.  相似文献   

7.
A capture enzyme-linked immunosorbent assay (ELISA) for detection of virus-specific immunoglobulin M (IgM) antibody was developed which used a panel of labeled monoclonal antibodies to rubella virus hemagglutinin. The rapidity of the test system was increased by using, after 1-h incubation of the test serum, a second 1-h incubation of the serum with a mixture of viral antigen and labeled monoclonal antibody. The new assay was tested for specificity on 371 human sera from people without any recent contact with rubella virus; of these, 66 were sera selected from people with rheumatoid factor or IgM antibody to human cytomegalovirus, Epstein-Barr virus, or other viruses. In parallel, the new assay was performed on 191 sera from patients having recent contact with rubella virus. Results were compared with those obtained by an indirect ELISA method on IgM serum fractions, using purified rubella virus as a solid phase. Of the 371 sera tested for specificity, 5 (1.3%) gave false-positive results with indirect ELISA (1 rheumatoid factor, 2 heterophil antibody, and 2 human cytomegalovirus sera positive for IgM), and none were false-positive with the capture assay. Two sera from a patient with primary cytomegalovirus infection, which were positive for rubella IgM antibody with both methods and were initially interpreted as false-positive, were finally considered to be true-positive, since they were reactive only in the presence of IgM antibody and viral antigen. Of the 191 sera from 92 patients (84 patients with acute rubella, four newborns from mothers with rubella during pregnancy, and four vaccinees), 136 (71.2%) were found to be positive for IgM by direct ELISA, and 128 (67.0%) were positive by capture ELISA; 12 sera drawn during the first 2 days of disease, or at least 40 days after onset (or after vaccination), were detected only by indirect ELISA, and 4 sera were detected only by capture ELISA. Thus, specificity and sensitivity, respectively, were 100 and 91.4% for capture ELISA and 98.6 and 97.1% for indirect ELISA. However, when the number of patients was considered, 86 were detected as IgM positive by indirect ELISA, and 87 were detected positive by capture ELISA. The overall agreement between the two assays was 96.2%. Capture ELISA using monoclonal antibody appears preferable over indirect ELISA on IgM serum fractions because of its higher specificity and shorter time for test performance; furthermore, there is no need for serum fractionation or virus purification for the capture ELISA.  相似文献   

8.
The aim of the study was evaluation of the utility of ELISA test using antigen A60 for rapid diagnosis of tuberculous menigitis (TBM) in paediatric age group. ELISA test based on mycrobacterial antigen A60 (Anda biological, France) was used to estimate specific IgM and IgG antibodies in the sera and CSF of 20 suspected cases of TBM which were selected on the basis of numerous parameters and were smear negative on concentrated smear of CSF. Sera of 20 Montoux negative healthy children was taken as control by detecting IgM and IgG antibodies to A60 antigen. Response to anti-tubercular treatment was observed in all the suspected cases of TBM. This study showed that specificity for diagnosis of TBM by detecting IgM and IgG antibodies in sera was 90% and 80% respectively. Sensitivity of the test by detecting IgM and IgG antibodies in sera was 85% and 80% respectively with positive predictive value of 89.47% for IgM antibody and 80% for IgG antibody. In CSF IgM and IgG antibodies were found in 75% and 60% cases respectively. Both were positive only in 60% of cases. It is concluded from this study that 80-85% cases of TBM in paediatric age group have eigher IgM or IgG antibodies in sera whereas 60-75% have antibodies in CSF.  相似文献   

9.
An enzyme-linked immunosorbent assay (ELISA) for detection of immunoglobulin M (IgM) antibodies against the periplasmatic flagellum of the Reiter treponeme is described. IgM in the test samples was bound to anti-IgM-coated microtest plates, and flagellum-specific IgM antibody was subsequently detected by incubation with a purified flagellum preparation and monospecific anti-flagellum conjugate. Rheumatoid factor, antinuclear antibodies, or flagellum-specific IgG did not interfere. The specificity of the ELISA for IgM antibodies was 99.5% for sera from 200 blood donors and 98.6% for 147 patient sera that gave false-positive reactions in other syphilis serological tests. The sensitivity was 88.5% for sera from 87 patients with first-time primary syphilis, 93.5% for sera from 62 patients with first-time secondary syphilis, 21.4% for sera from 42 patients who were reinfected, and 0% for sera from 13 patients with late syphilis. Of the sera from 153 patients with treated syphilis, 7.2% had IgM antibodies, and sera from patients with primary or secondary syphilis generally had no IgM antibodies 6 months after treatment. The finding of IgM antibodies indicates that patients should receive antisyphilis treatment if they have not been treated recently, but a negative result does not exclude the possibility of active syphilis. The method may prove useful for the diagnosis of congenital syphilis in newborns.  相似文献   

10.
The glycoprotein G (gG-2) purified from HSV-2 infected cells has been reported to be useful for determination of HSV-2 type-specific antibodies using conventional ELISA formats. This study further confirmed the specificity of gG-2 and demonstrated the feasibility of a specific IgM assay. The gG-2 ELISA was developed to detect HSV-2 specific IgG and IgM antibodies in human sera with high levels of sensitivity and specificity. Of 45 patients with culture-proven recurrent HSV-2 genital infection 44 were reactive for gG-2 IgG. Of 30 sera from patients with culture-proven recent initial HSV-2 genital infection 29 were positive for gG-2 IgM. Three patients with primary HSV-2 genital infection showed gG-2 IgM in the convalescent but not in the acute sera. The IgG- and IgM-gG-2 ELISA showed high specificity. None of 40 sera from children were reactive by either assay. Only one of 94 sera from patients with antibody to herpesviruses other than HSV reacted in the IgG assay but none reacted in the IgM assay. There was no cross-reaction with sera from patients with proven HSV-1 infection with the gG-2 antigen. The results suggest that the IgG assay can be used for demonstration of past HSV-2 infection and the IgM assay for the diagnosis of HSV-2 in neonatal herpes and primary genital herpes, when cultures or rapid diagnostic techniques are unavailable.  相似文献   

11.
McAb ELISA间接夹心法检测HFRS病人血清IgM和IgG抗体的研究   总被引:2,自引:0,他引:2  
肾综合征出血热(HFRS)早期临床症状不典型,因此在病人血清中检出特异性抗体,特别是IgM抗体对辅助临床诊断有重要意义。此外,HFRS的流行病学监测和病原学研究等都需有敏感、特异、简便而客观的  相似文献   

12.
An enzyme-linked immunosorbent assay (ELISA) for the detection of IgG and IgM antibodies against Mycoplasma pneumoniae, performed with commercial antigen and reagents, is compared with the complement fixation test (CF) in a serological study of 209 human sera. Concordant results were usually obtained by CF test and by IgG ELISA in sera from patients with recent M pneumoniae infection. In contrast, when used for an immunological survey of a general population, approximately 27% of the sera negative in the CF test were positive for IgG by the ELISA, and sera with low CF titres were found to have a broad range of IgG titre by the ELISA. This may be due to the greater sensitivity of the ELISA technique and/or to different types of antibody measured by both tests. IgM was detected by ELISA in sera from all patients with recent M pneumoniae infection diagnosed on the basis of clinical findings and by CF assay. Occasionally false-positive IgM antibodies were due to rheumatoid factor (RF); this potential interference necessitates routine testing of IgM antibody positive sera for RF.  相似文献   

13.
An indirect solid-phase enzyme-linked immunosorbent assay (ELISA) for the determination of specific IgM and IgG antibodies to echovirus type 11 in a single dilution of serum was developed using partially purified echovirus type 11 bound to microplates. Whole serum was used for IgG antibody but prior to assaying for IgM antibody interfering IgG was removed by ion exchange chromatography. The ELISA for echovirus type 11 IgG antibody was a more sensitive, rapid, technically easier and less costly alternative to the neutralisation test. With the IgG ELISA 12 of 132 sera (10.6%) known to contain enterovirus antibodies other than echovirus type 11 were positive but it could not be determined to what extent this was due to the greater sensitivity of the ELISA or cross-reactions. The IgM ELISA was even more sensitive than the IgG ELISA with acute sera, and showed a reactivity in 4 of 36 sera (11.1%) with no detectable echovirus type 11 neutralising antibodies. Echovirus type 11 IgM antibody was detected in all sera collected after the first week of infection and up to 30 days after infection. However, it was only detected in 58% of sera collected during the first week after onset thus limiting its use for rapid diagnosis. The echovirus type 11 IgM ELISA appears to have considerable laboratory diagnostic potential when a rising antibody level cannot be demonstrated in paired sera or when virus is not cultured.  相似文献   

14.
The enzyme-linked immunosorbent assay (ELISA) was used to detect leptospire-specific immunoglobulin M (IgM) and IgG in the sera of patients infected with leptospiral serovars hardjo, pomona, or copenhageni. All patients produced specific IgM and IgG detectable by ELISA. In contrast, only a few patients produced IgG agglutinins whereas all produced IgM agglutinins. The specificity and sensitivity of the test suggest that the ELISA anti-IgM technique is a suitable method for detecting leptospiral antibodies in human sera for diagnostic and epidemiological purposes.  相似文献   

15.
A homemade enzyme-linked immunosorbent assay (ELISA) and a dipstick assay (Dipstick) for the detection of anti-Entamoeba histolytica antibodies in serum were developed and evaluated together with a commercially available latex agglutination test (LAT; Laboratoires Fumouze) for their use in serodiagnosis of amebiasis. The sensitivity of these assays was evaluated with sera from 27 patients with radiologically proven, cellulose acetate precipitation (CAP) test-positive amebic liver abscess, 7 patients with parasitologically and PCR-proven amebic colitis, and 11 patients with parasitologically and PCR-proven E. histolytica cyst passage. The sensitivities of the ELISA, Dipstick, and LAT were all 93.3% (42/45). With a combination of Dipstick and LAT, all abscess and colitis patients had at least one positive result. The specificity was assessed with 238 sera from patients with various parasitic, bacterial, viral, and fungal infectious diseases, sera containing autoimmune antibodies, and sera from healthy blood donors. The specificities of the ELISA, Dipstick, and LAT were 97.1%, 98.1%, and 99.5%, respectively. Of 61 sera from patients with PCR-proven E. dispar infection, 60 (98.4%) were negative in both Dipstick and LAT and 59 (96.7%) were negative in ELISA. Our data suggest that all three assays are sensitive serological tests. The rapid LAT and Dipstick provide fast results and can easily be applied in routine laboratories in order to facilitate the diagnosis of amebiasis.  相似文献   

16.
An ELISA for the detection of anti-topoisomerase I autoantibodies in sera from patients with suspected or manifest rheumatic diseases is described. The antigen source used in this assay consists of a recombinant protein containing the last 695 C-terminal amino acid residues of human topoisomerase I (topo I). The sensitivity of the assay was 61%, while the specificity was more than 98%. Using this ELISA, 47 sera from scleroderma patients and immunopositive for anti-topo I antibodies, were screened for the presence of the isotypes IgG, IgA and IgM to topo I. Our finding that relatively high levels of IgA antibodies to topo I are present in most of the sera tested is consistent with the results of Hildebrandt et al. [1]. In addition, it is demonstrated that the IgG and IgA antibodies in a serum may recognize different epitope regions on the topo I polypeptide.  相似文献   

17.
18.
BACKGROUND: Serological detection of cytomegalovirus (CMV)-specific antibodies varies greatly due to antigen composition and the lack of antigen standardization. OBJECTIVES: To develop and evaluate a new ELISA with native and/or recombinant cytomegalovirus antigens for the detection of anti-CMV IgG and IgM antibodies. RESULTS: The diagnostic performance of three anti-CMV ELISAs coated with different CMV antigen preparations, (i) native CMV antigen, (ii) a mixture of recombinant CMV peptides pp150, pp28, gB2 and pp52 and (iii) a combination of native CMV antigens and recombinant CMV IE1 antigen applied in the new Genzyme Virotech CMV ELISA, were compared. All tested sera were derived from patients or healthy blood donors and were predefined with the Dade Behring Enzygnost((R)) CMV ELISA as well as by CMV PCR analysis. Additionally, official well-characterized serum panels were also tested. The new Genzyme Virotech CMV ELISA IgG/IgM test applying a combination of native antigens and recombinant IE1 antigen was evaluated and the performance was compared to the Dade Behring Enzygnost((R)) CMV ELISA. The sensitivities were 98.9% (IgG) and 98.2% (IgM), the specificities were 98.8% (IgG) and 98.9% (IgM) for the Genzyme Virotech CMV ELISA. Furthermore all sera of the BBI mixed titer performance panel as well as the BBI seroconversion panel were identified 100% correctly with the new Genzyme Virotech ELISA. CONCLUSIONS: These data suggest that the new Genzyme Virotech CMV ELISA has higher sensitivity and specificity than ELISAs based on native antigens or recombinant peptides only. Specific combinations of native and recombinant antigens increase the serological detection of CMV infections and may add to further standardization of CMV serology.  相似文献   

19.
Using recombinant 15- to 30-kDa fragments and fusion with glutathione S-transferase (GST), we investigated the seroreactivity of three large structural proteins of Epstein-Barr virus (EBV), p150 (BcLF1, capsid), p143 (BNRF1, tegument), and gp125 (BALF4, membrane) in Western blots. None of 13 fragments tested, however, was qualified for diagnostic application. In contrast, the two small viral capsid antigens (VCA), p18 (BFRF3) and p23 (BLRF2), demonstrated sensitive (100%) EBV-specific immunoglobulin G (IgG) reactivities. While p18 additionally showed maximum sensitivity for IgM detection, the IgM sensitivity of p23 was restricted (44%). An autologous fusion protein, p23-p18, which consists N-terminally of full-length p23, followed by the carboxy half of p18, was constructed. This antigen was subjected to indirect VCA enzyme-linked immunosorbent assays (ELISAs), for IgG and IgM, as well as to a micro-capture (microc) IgM ELISA. All assays were found to be 100% specific when EBV-negative sera were tested. Using sera from previously infected individuals, the p23-p18 fusion revealed an improved IgG sensitivity of 99% compared to sensitivities of 97 and 93% for the single antigens p18 and p23, respectively. The sensitivity and specificity of the indirect IgM ELISA with samples of primary and past infections, respectively, were 100%. The microc principle for IgM overcame completely the interference by rheumatoid factors. Compared to the specificity of the indirect IgM version, the specificity with sera collected from rheumatoid arthritis patients increased from 48 to 100%. In summary, the p23-p18 IgG and microc IgM ELISAs showed excellent performances and are promising new diagnostic tests for the detection of EBV-specific antiviral capsid antibodies.  相似文献   

20.
An enzyme-linked immunosorbent assay (ELISA) for detection of immunoglobulin G (IgG) and IgM to cardiolipin, lecithin, and cholesterol (VDRL [Venereal Disease Research Laboratory] ELISA) is described. The specificity of the VDRL ELISA for IgG and IgM was 99.6 and 99.5%, respectively, with sera from 1,008 persons without syphilis. For a group of patients with false-positive results in traditional nontreponemal tests and for patients with autoimmune diseases, the VDRL ELISA for IgG had a higher specificity than the VDRL ELISA for IgM. The sensitivity for IgG and IgM with 118 sera from patients with untreated syphilis was 96.6 and 94.9%, respectively, which was equivalent to the sensitivities of the traditional nontreponemal tests. The performance of the VDRL ELISA was compared with that of an ELISA that uses cardiolipin as the antigen (cardiolipin ELISA). The VDRL ELISA was significantly more sensitive (P less than or equal to 0.01) than the cardiolipin ELISA with 25 sera from syphilis patients but was less sensitive (P less than or equal to 0.01) with 53 sera from patients with autoimmune diseases. The antibody reactivity in the VDRL ELISA could not be absorbed out by lecithin and cholesterol, and the sera from patients with syphilis did not react in an ELISA that uses cholesterol and lecithin as the antigen. This indicates that cholesterol and lecithin, although not antigenic by themselves, may change the structural form of the epitope on cardiolipin so that it becomes more recognizable for antibodies in syphilis and less recognizable for antibodies in autoimmune diseases. The results of the VDRL ELISA were expressed in percentages of the absorbance value of a positive control. The VDRL ELISA gave, without titration of sera, quantitative results that correlated with the quantitative results of the traditional nontreponemal tests obtained by titration. The VDRL ELISA will be well suited for large-scale testing for syphilis and may replace other nontreponemal tests.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号