首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 0 毫秒
1.
2.
Dora C  Schmid MR  Elfering A  Zanetti M  Hodler J  Boos N 《Radiology》2005,235(2):562-567
PURPOSE: To retrospectively evaluate if the degree of disk degeneration and disk herniation volume at magnetic resonance (MR) imaging are risk factors for recurrent disk herniation. MATERIALS AND METHODS: The institutional review board permits such retrospective studies, and individual informed consent was not required. MR imaging findings obtained before initial diskectomy in 30 patients (mean age, 42.8 years; 10 women, 20 men) with recurrent disk herniation (study group) and 30 patients (mean age, 42.2 years; nine women, 21 men) without recurrence for at least 2 years after surgery (control group) were compared. Disk degeneration was assessed on T2-weighted sagittal MR images with a five-point grading system (grade I indicated no degeneration; grade II, horizontal hypointense bands within disk; grade III, inhomogeneous disk with intermediate signal intensity; grade IV, no distinction between inner and outer parts of disk; and grade V, collapsed hypointense disk). Disk herniation was classified as representing protrusion, extrusion, or sequestration. The volume of both the affected intervertebral disk and the herniated disk material was measured. Qualitative and quantitative analyses were performed by two readers. The chi(2) test was used for comparison of categorical variables. For comparison of disk degeneration and volumes between patients with and those without recurrence, a paired two-tailed t test was used. Odds ratios based on the extent of disk degeneration were calculated for the entire sample. RESULTS: Advanced disk degeneration (grades IV and V) was significantly less frequent in the study group than in the control group (P < .006). The risk of recurrent disk herniation decreased by a factor of 3.4 for each increase in grade of disk degeneration (odds ratio: 3.58; 95% confidence interval: 1.3, 9.6; P = .011). Mean disk herniation volume as a percentage of intervertebral disk volume was 10.59% +/- 3.41 in the study group and 11.56% +/- 3.84 in the control group. This difference was not significant (P = .31). CONCLUSION: Minor disk degeneration but not herniation volume represents a risk factor for the recurrence of disk herniation after diskectomy.  相似文献   

3.
PURPOSE: To determine if radiographic, computed tomographic (CT), and magnetic resonance (MR) imaging findings can help differentiate spinal neuropathic arthropathy from disk space infection. MATERIALS AND METHODS: Imaging studies in 33 patients were evaluated, including 14 patients with spinal neuropathic arthropathy (12 radiographic, seven CT, and six MR studies) and 19 with disk space infection (13 radiographic, nine CT, and 12 MR studies). Potential imaging discriminators, including endplate sclerosis or erosions, osteophytes, spondylolisthesis, facet involvement (narrowing or erosions), vacuum disk, paraspinal soft-tissue mass, joint disorganization, and osseous joint debris, were recorded, as were MR imaging signal intensity and gadolinium-enhancement characteristics. RESULTS: The most helpful findings for diagnosis of spinal neuropathic arthropathy were vacuum disk on radiographs and CT images, debris on radiographs and CT and MR images, disorganization on radiographs and CT and MR images, facet involvement on radiographs and CT and MR images, spondylolisthesis on CT and MR images, diffuse signal intensity patterns in vertebral bodies on MR images, and rim enhancement of disks on gadolinium-enhanced MR images. Findings that were not helpful included endplate sclerosis and erosions, osteophytes, paraspinal soft-tissue mass, and decreased disk height. CONCLUSION: Vacuum disk, facet involvement, vertebral body spondylolisthesis, joint disorganization and debris, and gadolinium-enhancement patterns of vertebral bodies and disks may help differentiate spinal neuropathic arthropathy from infection.  相似文献   

4.
5.
Method of electrodeposition on rotating disk cathode (RDE) is applied for preparation of Np, Pu and Am α-standards. Phenomenon of critical current density is experimentally observed which is in perfect accord with Hansen's theory of electrodeposition. Influence of deposit calcination regime on quality of α-sources is studied, and comparison is made of uniformity of deposits obtained in various deposition systems. Standards with energy resolution better than 9 keV can be reproduceably obtained by optimized RDE electrodeposition technique.  相似文献   

6.
The objective of our study was to support algorithmic recommendations for the appropriate sizing of picture archiving and communication system (PACS) caches. For a large PACS installation, a detailed analysis of current radiographic (CR), CT and MRI studies (n=400 consecutive studies, respectively) was performed. In this process every available prior examination was also considered. A new algorithmic procedure for appropriate sizing of PACS caches was developed and applied to the given cache implementation. The number of all priors was 7.6±12.3. Of them, 61% were relevant priors with an average age of 203±385 days. A basic cache (BC) that covers 12 months of current imaging results in a pre-fetching quote of 15.4% (8.6% for 24 months). In the PACS installation examined, a minimal threefold increase in cache capacity was recommended. Studies that are retrieved, prior to viewing, from the long-term archive require additional space in the extended cache (EC). An intimate and mutual interaction between hospital information system (HIS), radiology information system (RIS) and PACS minimizes this requirement and increases the time during which actual image material from the BC is available online. A basic cache size covering actual imaging of 12 months up to 24 months is recommended. The parameters governing the individual dimensions of both cache spaces and a mathematical algorithm are demonstrated.  相似文献   

7.
The primary objective of this study conducted on 100 patients is to demonstrate that performing CT-guided percutaneous discectomy for herniated disks results in a significant improvement in pain symptoms at several times (D1, D2, D7, 1 month, 3 months, 6 months). This objective assesses the effectiveness and feasibility of this technique under CT guidance in patients presenting documented lower back pain related to disk herniation that has not improved with appropriate medical treatment. The impact of various factors on the effectiveness of discectomy will also be evaluated. At 1 week, we notes a decrease in average VAS respectively of 71% and 67% in patients treated for posterolateral and foraminal herniated disks; the result for posteromedian herniated disks is only 45% in average decrease. At 6 months post op, 79% of lateralized herniated disks have a satisfactory result (≥ 70% decrease in pain as compared to initial pain), whereas post median herniated disks had a satisfactory result in only 50% of cases. Percutaneous fine needle discectomy probe under combined CT and fluoroscopic guidance is a minimally invasive spine surgery which should be considered as an alternative to surgery. This technique presents several advantages: the small diameter of the probe used (maximum 16 G or 1.5mm) allows a cutaneous incision of only a few millimeters, and a trans-canal approach can be possible; it also decreases the risk of ligamentary lesion and does not cause an osseous lesion of the posterior arc or of the adjacent muscular structures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号