首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
《The Knee》2020,27(5):1646-1659
BackgroundThe purpose of the present study was to measure the intraoperative joint gap using tensor device and pre- and, postoperative joint stability at 0, 30 and 90° of flexion using stress radiography and to identify whether these factors influence patient-reported outcome measurement (PROM) in anatomical bi-cruciate retaining (BCR) knee arthroplasty (TKA).MethodsFifty-three knees with preoperative varus osteoarthritis of the knee underwent anatomical BCR TKA with oblique 3° angle femorotibial joint line. The intraoperative medial and lateral joint gap using a tensor device and gap difference (lateral minus medial; varus laxity) were also calculated. Postoperative joint stability was measured using stress radiographs. PROM was also evaluated at 1.5 years postoperatively. The effect of intraoperative and postoperative joint stabilities on PROMs were analyzed using Spearman’s rank correlation analysis.ResultsIntraoperative greater difference between medial joint gap at 140° and 0° of flexion showed significant positive correlation with postoperative function of patellofemoral joint. Intraoperative varus laxity at extension improved postoperative symptoms in 2011 Knee Society Score (2011 KSS); greater postoperative lateral stability at 30 and 90° of flexion with the varus stress test was associated with the better patient expectation in 2011 KSS. Postoperative medial laxity at 90° of flexion with the valgus stress test positively correlated with the patient expectation and satisfaction in 2011 KSS.ConclusionSurgeons should notice that the postoperative lateral stability and medial laxity at 90° of flexion improved PROM in anatomical BCR TKA.  相似文献   

2.
BackgroundComponent gap (CG) measurement help surgeons evaluate intraoperative soft-tissue balance. One technique is measuring the CG using tensioner devices with distraction force. Another is to evaluate the laxity under a varus–valgus force using navigation or robotics. The aim was to compare the JL evaluated by CG and varus–valgus force between the different types of total knee arthroplasties.MethodsForty-three bi-cruciate stabilized (BCS) knees and 33 bi-cruciate retaining (BCR) knees were included. After bone resection and soft tissue balancing, the CG was measured and after the final implantation and capsule closure, JL under a maximum varus–valgus stress was recorded with navigation. JL evaluated by the CG (JLCG) was defined as CG minus selected thickness of the tibial component and JL under varus–valgus force (JLVV) was defined as difference between varus–valgus angles without stress and maximum varus–valgus angles under varus–valgus force. The evaluations were performed at flexions of 10°, 30°, 60° and 90°.ResultsAlthough JLCGs of lateral compartment of BCS were larger than those of BCR, no difference was found between JLVVs of BCS and BCR. Although JLCGs of lateral compartment did not change at each knee flexion angle in both BCS and BCR, JLVVs of lateral compartment increased by 3° from 10° to 90° knee flexion.ConclusionJLVVs of BCS and BCR were equivalent, whereas BCS showed larger JLCGs of lateral compartment. JLVVs of lateral compartment increased by 3° in the range from 10° to 90° knee flexion whereas JLCGs remained stable.  相似文献   

3.
BackgroundAppropriate soft tissue balance and accurate alignment are important for successful total knee arthroplasty (TKA). However, the optimal technique for establishing and measuring soft tissue balancing remains unclear. The aim of this study was to analyze the intraoperative medial and lateral gap pattern using digital knee balancer in posterior-stabilized (PS) TKA.MethodsThis study involved 55 patients with medial osteoarthritis who underwent a primary TKA using an image-free navigation system. The extension gap and the flexion gap at 90° knee flexion were assessed using an offset seesaw-type digital balancer. Continuous joint distraction force from 10 lb to 60 lb was applied. Medial gap, lateral gap, and varus angle were measured.ResultsThe medial bone gap difference between extension and flexion was constant regardless of the distraction force from 20 lb to 60 lb. The lateral bone gap was significantly greater than the medial bone gap in extension and flexion from 30 lb to 60 lb (P < 0.05). The varus angle changed depending on the distraction force, especially in flexion. The varus angle in flexion was significantly greater than that in extension from 40 lb to 60 lb (P < 0.05).ConclusionsThe medial bone gap is a reliable indicator unaffected by the distraction force during surgery and is useful for adjusting the medial gap in extension and flexion appropriately to ensure medial stability in PS-TKA. The digital knee balancer and navigation system support both precise gap assessment and surgery.  相似文献   

4.
《The Knee》2020,27(5):1534-1541
BackgroundThe purpose of the present study was to measure the intraoperative joint gap using tensor device and pre- and, postoperative joint stability at 0, 30 and 90° of flexion using stress radiography and to identify whether these factors influence patient-reported outcome measurement (PROM) in anatomical bi-cruciate retaining (BCR) knee arthroplasty (TKA).MethodsFifty-three knees with preoperative varus osteoarthritis of the knee underwent anatomical BCR TKA with oblique three-degree angle femorotibial joint line. The intraoperative medial and lateral joint gap using a tensor device and gap difference (lateral minus medial; varus laxity) were also calculated. Postoperative joint stability was measured using stress radiographs. PROM was also evaluated at 1.5 years postoperatively. The effect of intraoperative and postoperative joint stabilities on PROMs were analyzed using Spearman's rank correlation analysis.ResultsIntraoperative greater difference between medial joint gap at 140° and 0° of flexion showed significant positive correlation with postoperative function of patellofemoral joint. Intraoperative varus laxity at extension improved postoperative symptoms in 2011 Knee Society Score (2011 KSS); greater postoperative lateral stability at 30 and 90° of flexion with the varus stress test was associated with the better patient expectation in 2011 KSS. Postoperative medial laxity at 90° of flexion with the valgus stress test positively correlated with the patient expectation and satisfaction in 2011 KSS.ConclusionsSurgeons should notice that the postoperative lateral stability and medial laxity at 90° of flexion improved PROM in anatomical BCR TKA.  相似文献   

5.

Background

Proper soft tissue balance is crucial for a successful clinical outcome after total knee arthroplasty (TKA). Bi-cruciate substituting (BCS)-TKA has been developed to more closely approximate normal knee characteristics. The purpose of the present study was to evaluate midflexion laxity before and after BCS-TKA using a navigation system, and assess the correlation between intraoperative laxity and the maximum flexion angle after surgery.

Methods

Fifty-one knees in 46 patients with osteoarthritis replaced with BCS prosthesis were assessed. Manual mild passive internal–external rotational and varus–valgus stress was applied to the knees, and the maximum total laxity was measured automatically by a navigation system before and after TKA. The correlations with the range of motion (ROM) were evaluated using Spearman's correlation coefficients (ρ).

Results

Internal–external stress assessment revealed no statistically significant difference at each flexion angle before and after BCS-TKA. In contrast, the varus–valgus stress assessment revealed that BCS-TKA had significantly decreased varus–valgus laxity from preoperative levels at 20–120° flexion angles. Furthermore, the maximum flexion angle at six months after surgery significantly correlated with the intraoperative laxity at deep flexion range.

Conclusion

BCS-TKA stabilized varus–valgus laxity to better than preoperative levels at midflexion range.  相似文献   

6.
《The Knee》2014,21(4):810-814
BackgroundSoft-tissue balancing of the knee is fundamental to the success of a total knee arthroplasty (TKA). In posterior-stabilized TKA, there is no stabilizer of the anterior–posterior translation in the midflexion range in which the cam-post mechanism does not engage yet. Therefore, instability in the midflexion range is suspected to occur in posterior-stabilized TKA. The purpose of this study was to measure the joint gap throughout a full range of motion and to analyze the joint gap laxity in the midflexion range after implantation of a mobile-bearing posterior-stabilized total knee prosthesis.MethodsJoint gap kinematics in 259 knees with varus osteoarthritis were measured during TKAs using a tensor device with the same shape of a total knee prosthesis of the same design was used. After the implantation of a mobile-bearing posterior-stabilized prosthesis and the reduction of the patellofemoral joint, the joint gap was measured at 0°, 30°, 60°, 90°, 120°, and 145° of flexion.ResultsThe center size of the joint gap was tight in extension and deep flexion and loose at midflexion ranges, especially at 30° of flexion (p < 0.001). The symmetry of the joint gap was varus at 0° and 145° of flexion (p < 0.001).ConclusionsOur results showed the joint gap laxity in the midflexion range after the implantation of a mobile-bearing posterior-stabilized prosthesis. Our new tensor device, which can attach the polyethylene insert trial, will provide the important information about the joint gap kinematics after implantation of total knee prostheses.Level of evidenceIV.  相似文献   

7.
BackgroundThe relationship between the femoral component design in total knee arthroplasty (TKA) and the patellofemoral contact force, as well as the soft tissue balance, has not been well reported thus far.MethodsTwenty-eight mobile-bearing posterior-stabilized (PS) TKAs using the traditional model (PFC Sigma) and 27 mobile-bearing PS TKAs using the latest model (Attune) were included. Surgeries were performed using the measured resection technique assisted with the computed tomography (CT)-based free-hand navigation system. After all the trial components were placed, patellar contact forces on the medial and lateral sides were measured using two uniaxial ultrathin force transducers with the knee at 0°, 10°, 30°, 60°, 90°, 120°, and 135° of flexion. The joint component gap and the varus ligament balance of the femorotibial joint were also measured. The non-paired Student’s t-test was conducted to compare the values of the two groups.ResultsThe medial patellar contact force was significantly lower for Attune group than for PFC Sigma group at 120° of knee flexion (P = 0.0058). The lateral patellar contact force was also significantly lower for Attune group than PFC Sigma group at 120° and 135° of knee flexion (P = 0.0068 and P = 0.036). The joint component gap, as well as the varus ligament balance, showed no statistically significant difference between the two groups.ConclusionsReduced thickness and width of the anterior flange of the femoral component in the Attune may play a role in low patellar contact force.  相似文献   

8.
BackgroundDetailed kinematics of floor-sitting activities after total knee arthroplasty (TKA) have not been well explored. Knee kinematics of cross-legged sitting, seiza-sitting, and side-sitting after TKA were examined to clarify the differences in tibiofemoral kinematics of each activity.MethodsSubjects were 40 knees in 20 osteoarthritic patients who underwent bilateral TKA with a high-flexion fixed-bearing posterior-stabilized prosthesis. Dynamic radiographs of floor-sitting activities were taken, and the knee kinematics were compared among the three activities. The patients were also divided into two groups (possible/easy group and impossible/no-try group) for each activity, and group comparisons were conducted.ResultsThe maximum implant flexion angle was significantly greater in seiza-sitting. In valgus/varus rotation, seiza-sitting demonstrated neutral rotation, while cross-legged sitting showed varus of about 10°, and side-sitting exhibited valgus. In tibial internal/external rotation, seiza-sitting demonstrated a constant rotational angle, while cross-legged sitting showed tibial internal rotation with flexion, and side-sitting exhibited tibial external rotation with flexion. The kinematic pathway during deep flexion illustrated the medial pivot pattern in cross-legged sitting, a small amount of bicondylar rollback in seiza-sitting, and the weak lateral pivot pattern in side-sitting. A greater flexion angle was the important factor for the performance of each floor-sitting activity followed by varus laxity at 10° knee flexion.ConclusionsThis study successfully revealed characteristic kinematic patterns of TKA knees in three floor-sitting activities. Obtaining a greater knee flexion with adequate lateral laxity is the key to enhancing postoperative floor-sitting activities.  相似文献   

9.
《The Knee》2020,27(3):1071-1077
BackgroundDifferences in measurement outcomes using different tensors in total knee arthroplasty (TKA) remain unknown. This study aimed to compare intraoperative soft tissue balance between two measurement systems in TKA.MethodsThis study included 24 cruciate-retaining (CR) and 27 posterior-stabilized (PS) TKAs for varus-type osteoarthritis. All TKAs were performed with the measured resection technique. Intraoperative soft tissue balance was assessed with femoral component placement and patellofemoral joint reduction throughout the range of motion. Measurements were performed using the Offset Repo-Tensor (Zimmer) and Ligament Sensor Tensor (Depuy). Joint component gaps and varus/valgus ligament balance were compared statistically in CR and PS TKAs.ResultsJoint component gaps with the Offset Repo-Tensor were significantly larger at 0°, 10°, 30°, and 60° of knee flexion in CR TKA and at all knee flexion angles, except 0° and 135°, in PS TKA than those with the Ligament Sensor Tensor (P < .05). Varus balance with the Offset Repo-Tensor was significantly larger at 0°, 10°, and 30° of knee flexion in CR TKA and at 10°, 30°, 60°, 90°, and 120° of knee flexion in PS TKA than that with the Ligament Sensor Tensor (P < .05).ConclusionSurgeons should consider the discrepancy in assessing intraoperative soft tissue balance depending on the tensor used. The Ligament Sensor Tensor tended to underestimate soft tissue balance in CR and PS TKAs compared with the Offset Repo-Tensor, especially in PS TKA. Thus, surgeons should know the difference in values between the offset-type tensor with consistent distraction force and a spring-loaded tensor.  相似文献   

10.
BackgroundSoft tissue balance is important for the success of total knee arthroplasty (TKA). Various types of tensors have been developed for the precise measurement of a gap. We hypothesized that the surface shape of the tensor that contacted the TKA component affected the gap measurement. This study aimed to compare the gaps obtained with flat and insert-shaped surface tensors.MethodsTwo senior surgeons performed 95 TKAs (Vanguard-PS:55 knees; Persona-PS:40 knees). The joint gap was measured in each static knee flexion status (0°, 30°, 45°, 60°, 90°, 120°, and full flexion). We compared the gaps measured with a flat surface tensor and an insert-shape surface tensor. We defined a significant change as a gap difference of >1 mm with a statistical significance.ResultsIn Vanguard-PS, significant changes were observed at 30° and 45°. In Persona-PS, significant changes were observed at 30°, 45°, and 60°. In both implants, gaps measured with the flat tensor were larger than those measured with the insert tensor at approximately midflexion, and the significant changes disappeared in higher flexion position over midflexion.ConclusionsThe surface shape of the tensor affected the measurement of midflexion laxity in TKA. When measuring the gap with a flat tensor, the midflexion laxity was overestimated. A tensor with an insert-shaped surface should be used to measure the gap in TKA.  相似文献   

11.

Background

Total knee designs that attempt to reproduce more physiological knee kinematics are gaining attention given their possible improvement in functional outcomes. This study examined if a total knee designed for anatomic motion, where the soft tissue balancing was intended to replicate anatomical tibiofemoral contact forces, can more closely reproduce the laxity of the native knee.

Methods

In an ex-vivo setting, the laxity envelope of the knees from nine lower extremity specimens was measured using a rig that reproduced surgical conditions. The rig allowed application of a constant varus/valgus (V/V) and internal-external (I/E) torque through the range of motion. After testing the native knee, total knee arthroplasty (TKA) was performed using the Journey II bi-cruciate substituting implant. Soft tissue balancing was guided by targeting anatomical compressive forces in the lateral and medial tibiofemoral joints with an instrumented tibial trial. After TKA surgery, the laxity tests were repeated and compared to the native condition.

Results

The TKA knee closely reproduced the coronal laxity of the native knee, except for a difference at 90° of flexion for valgus laxity. Looking at the rotational laxity, the implant constrained the internal rotation relative to the native knee at 45 and 60° of flexion. The forces on the tibial trial for the neutral path of motion showed higher values on the medial side as the knee flexed.

Conclusions

This study suggested that when using an anatomically-designed knee, the soft tissue balancing should also aim for anatomical contact forces, which will result in close to normal laxity patterns.  相似文献   

12.
Lo J  Müller O  Dilger T  Wülker N  Wünschel M 《The Knee》2011,18(6):491-495
This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior–posterior translation, valgus–varus, and internal–external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease.  相似文献   

13.
BackgroundSoft tissue balancing in bicruciate-retaining (BCR) total knee arthroplasty (TKA) is a challenge that must be overcome to achieve excellent clinical outcomes. However, the optimal degree of joint laxity has yet to be clarified. This cadaveric study sought to examine joint laxity after BCR TKA using a navigation system.MethodsKnee joint laxity was quantified using an image-free navigation system in 8 intact fresh frozen cadavers under three conditions: the native knee, BCR TKA knee, and BCR TKA knee after anterior cruciate ligament resection. Rotational kinematics in the BCR TKA knee during flexion were compared according to whether joint laxity was increased or decreased.ResultsKnee joint laxity after BCR TKA under varus-valgus movement, anterior translation, and internal-external rotation loadings was similar to that of the native knee. However, lateral joint laxity was decreased during flexion in some cases. BCR TKA-treated knees with decreased lateral joint laxity at 90° of flexion demonstrated more limited tibial internal rotation in deep flexion than the native knee (p < 0.05). The loss of internal rotation in deep flexion was partly recovered by using a lateral insert with a posterior slope of +3°.ConclusionsRestoring optimal joint laxity was not always straightforward in BCR TKA if the 4 ligaments were preserved. Lateral joint laxity was potentially decreased in BCR TKA and may result in kinematic conflict during flexion. Surgeons should be aware of the need to achieve sufficient lateral joint laxity in this type of BCR TKA.  相似文献   

14.
BackgroundIt is generally believed that contraction of the soft tissue structures on the medial side may occur in the knee with severe varus deformity. However, the relationship between the severity of varus deformity of the knee and the intraoperative soft tissue balance in unicompartmental knee arthroplasty (UKA) has not been well reported thus far.MethodsOne hundred and three consecutive medial UKAs were enrolled. After the femoral trial prosthesis was placed, the component gap was measured at 10° (extension) and 120° (flexion) of flexion using a UKA tensor. The pre-osteotomy gap was then calculated from the thickness of the bone cut. Paired Student’s t-test was used to compare the component gap, as well as the pre-osteotomy gap, in extension and those in flexion. The relationship between the preoperative Hip-Knee-Ankle (HKA) angle and the pre-osteotomy gap was analysed using Pearson’s correlation coefficient and simple linear regression analysis.ResultsThe component gap in extension was significantly smaller than that in flexion while the pre-osteotomy gap in extension was significantly wider than that in flexion. There was a positive correlation between the severity of varus deformation in preoperative knee and the pre-osteotomy gap in extension, while there was no correlation between the preoperative HKA angle and the pre-osteotomy gap in flexion.ConclusionsThe tension of the medial tightness does not correlate with the degree of preoperative varus deformity in UKA.  相似文献   

15.
BackgroundThere is no consensus regarding femorotibial rotational kinematics in total knee arthroplasty (TKA) for valgus knee deformity. Additionally, whether the degree of valgus deformity influences intraoperative rotational kinematics and postoperative clinical scores remains unclear. The objectives of this study were to investigate whether the valgus angle is associated with intraoperative rotational kinematics in TKA for valgus knee deformity and to examine the relationship between rotational kinematics and postoperative clinical results.Materials and methodsA total of 24 knees with valgus deformity for TKA were included in this study and were divided into two groups depending on the femorotibial angle (FTA); there were 11 knees in the severe valgus group (FTA < 160°) and 13 knees in the mild valgus group (FTA ≥ 160°). Intraoperative femorotibial rotational kinematics from knee extension to flexion were evaluated using an image-free navigation system and postoperative clinical results (range of motion and subjective outcomes) were evaluated 1 year postoperatively. All parameters were compared between the two groups.ResultMild valgus knee showed tibial internal rotation during knee flexion before implantation, whereas severe valgus knee showed tibial external rotation during knee flexion before implantation. The postoperative flexion angle was positively correlated with the tibial internal rotation angle after implantation in the mild valgus group only.ConclusionIntraoperative rotational kinematics before implantation differed between mild and severe valgus knee deformity in TKA. Intraoperative tibial rotation influenced the postoperative knee flexion angle in mild, but not severe, valgus knee deformity. Ideal postoperative rotational kinematics may be different between the two groups and the difference may be taken into consideration in implant selections and surgical techniques.  相似文献   

16.
In image-free total knee arthroplasty (TKA) navigation, infra-red markers are attached to bony landmarks to provide kinematic data intra-operatively, with the aim of improving the precision of implant placement. In non-invasive navigation, infra-red markers are attached to the skin surface, with recent evidence suggesting that this can give repeatable measurements of lower limb mechanical alignment. The aim of our study was to evaluate the use of a non-invasive navigation system in the assessment of mechanical alignment with applied coronal force through the range of flexion. A previously validated non-invasive system (Physiopilot?) was tested on 23 volunteers with healthy knees. Two users performed two registrations of the software workflow on each participant’s right and left knees. A force was manually applied to the end-point of varus and valgus knee laxity and the measured change in mechanical alignment was recorded. Force was applied with the knee positioned in increments of flexion from 0 to 90°. In keeping with previous studies, satisfactory values of coefficient of repeatability (CR) of 1.55 and 1.33 were found for intra-observer repeatability in measurement of supine mechanical femoro-tibial angle (MFTA) in extension, with a good inter-observer correlation of intraclass correlation coefficient (ICC) .72. However, when flexion was introduced, intra-observer and inter-observer reliability fell out with acceptable limits. Therefore, the trial did not support use of the Physiopilot? system as a measure of MFTA when flexion is introduced. It was felt that learning-curve, soft tissue artefacts and lack of force standardisation equipment may have accounted for significant levels of error, with further studies required to address these issues.  相似文献   

17.
BackgroundImplant design and surgical techniques affect postoperative knee kinematics in total knee arthroplasty (TKA). This study aimed to compare femoral roll-back between cruciate-retaining (CR) and posterior-stabilized (PS) TKA in the same knee by objectively quantifying the contact point kinematics of the tibiofemoral joint using a sensor.MethodsIn the present prospective study, we used an intraoperative sensor to compare medial and lateral roll-back during 0-120° knee flexion in 33 knees that underwent CR and PS TKA. We also examined the relationship between mediolateral balance and the lateral-to-medial roll-back ratio. We defined the contact percentage position as the vertical length to the contact point divided by the anteroposterior length of the tibial plate.ResultsThe roll-back percentage following PS TKA (19.8 ± 5.1%) was significantly higher than that after CR TKA in both the medial (19.8 ± 5.1% versus 7.1 ± 2.5%, P < 0.001) and lateral (26.8% ± 3.8% versus 18.7 ± 3.8%, P < 0.001) compartments. The medial contact pressure at 90° was significantly correlated with the increased lateral-to-medial roll-back ratio in both CR and PS TKA (both P < 0.001).ConclusionPS TKA resulted in a higher percentage of femoral roll-back in the medial and lateral compartments than CR TKA. CR TKA caused a higher lateral-to-medial roll-back ratio compared to PS TKA. To reproduce medial pivot knee motion similar to that of a normal knee, the medial soft tissue needed to be balanced more tightly than the lateral soft tissue during TKA. These findings provide some clinical evidence of TKA design selection and proper mediolateral balancing for successful TKA.  相似文献   

18.
Background“Mid-flexion stability” is important for superior patient satisfaction following total knee arthroplasty (TKA). Thus, it is important to control medial joint gap intraoperatively as a countermeasure. However, reports on the precise intraoperative changes in medial joint gap during TKA are scarce. This study evaluated the intraoperative changes in medial joint gap during TKA.MethodsWe studied 167 knees with varus osteoarthritis that underwent 80 cruciate-retaining (CR) and 87 posterior-stabilized (PS) TKAs between January 2018 and December 2020. We measured the intraoperative changes in medial joint gap with a tensor device at 137.5 N.ResultsThe medial joint gap after posterior femoral condylar resection was significantly increased not only at 90° of flexion but also at 0° of extension in CR and PS TKAs (p < 0.01). The medial joint gap after posterior osteophyte removal was significantly increased not only at 0° of extension but also at 90° of flexion in CR and PS TKAs (p < 0.01). The medial joint gap at 0° of extension was reduced by 0.60 mm after femoral component placement in PS TKA.ConclusionSurgeons need to pay close attention to these intraoperative changes in medial joint gap by measuring the medial joint gap before and after each procedure or assuming the changes in those values before bone cutting to achieve superior patient satisfaction following TKA.  相似文献   

19.
BackgroundDuring total knee arthroplasty (TKA), most surgeons align the femoral component along the surgical epicondylar axis (SEA) considering it as orthogonal to the femoral mechanical axis. However, it is still unclear how SEA coronal alignment varies according to the native coronal knee alignment. The main goal of this study was to analyze the SEA orientation according to the native coronal knee morphotype.MethodsA total of 112 patients underwent a three-dimensional (3D) -planning-based TKA. The SEA was then determined by locating the epicondyles on 3D models. The 3D femoral and tibial mechanical axes were marked and the femoral (FMA) and tibial (TMA) mechanical angles were measured. The native HKA angle was measured as FMA + TMA. The SEA orientation angles were measured in the coronal (SEA-α) and axial (SEA-β) plane. SEA orientation was compared between the valgus, neutral, and varus knees.ResultsThe mean SEA-α angle was 90.2 ± 3° and the mean axial SEA-β angle was 92.2 ± 1.3°. The SEA-α angle was significantly higher in the valgus group compared with the neutral group (92.3 ± 2.9°, 90 ± 2.9°, P = 0.0009) whereas there was no significant difference in the SEA-α angle between the varus and the neutral group (89.7 ± 2.3°, 90 ± 2.9°, P = 0.32).ConclusionsIn contrast to the neutral and varus knees, the SEA was not orthogonal to the femoral mechanical axis in patients undergoing TKA for primary osteoarthritis. Our results suggest adapting the coronal alignment of the femoral component during TKA, while maintaining an average 2° valgus in valgus knees. By contrast, with varus and neutral knees, our data support the use of a mechanical alignment.  相似文献   

20.
BackgroundIt is unknown whether intraoperative kinematics of bicruciate-stabilized total knee arthroplasty (BCS-TKA) are different for different activities. It has also not been established whether intraoperative high-flexion motions correlate with postoperative patient-reported outcome measures (PROMs). We aimed to clarify the intraoperative kinematics of BCS-TKA during high-flexion activities and describe the relationship between intraoperative and postoperative patient-reported outcomes.MethodsWe examined 33 knees from 31 patients who underwent BCS-TKA and measured intraoperative knee kinematics, passive knee flexion, and cross-legged flexion using a navigation system. We also calculated knee flexion, varus-valgus, and rotation angles. As a secondary evaluation, we divided the patients into two clusters based on the PROMs and compared the kinematics between them.ResultsThe valgus moved by 1.3 ± 1.3° beyond 90° knee flexion during passive flexion. In contrast, during cross-legged flexion, the varus moved by 4.6 ± 5.1° beyond 30° flexion. This indicated significantly increased varus alignment in the cross-legged flexion as compared with passive flexion. Beyond 60° of flexion, the femur displayed 8.8 ± 4.8° of external rotation relative to the tibia. In cross-legged flexion, the femur displayed 9.2 ± 6.5° of external rotation relative to the tibia beyond 45° of flexion. At 90° of flexion, the cross-legged knees rotated more externally. There were no significant postoperative differences between the high- and low-score clusters.ConclusionThe intraoperative knee kinematics after BCS-TKA during high-flexion motions differed depending on the performance of an individual. This will be useful for physicians who might recommend BCS-TKA to new patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号