Recent studies indicate that eddy currents generated by the sinuses of Valsalva play an important role in the physiologic closure of the aortic valve. This process is briefly discussed and evidence is presented that this fact was well known and elaborated upon by the renaissance artist Leonardo da Vinci. This fact is illustrated with his words and drawings.  相似文献   

6.
7.
Study objectiveEstablish the transcultural validity of Anesthetists Non-Technical Skills (ANTS) in a Spanish-speaking country.DesignProspective cohort.SettingClinical simulation center.SubjectsForty-two Anesthesia PY2 and PY3 residents participated in the study.InterventionsFour clinical scenarios simulating anesthesia crises were assessed with a Spanish version of ANTS. Every simulated scenario was run twice with a time span of 3 to 4 months between them.MeasurementsTwo anesthesiologists independently assessed all simulated sessions using ANTS. The ANTS indicators of construct validity were obtained by confirmatory factor analysis. Various goodness-of-fit indices of the factorial model were calculated: Comparative Fit Index (CFI); Tucker-Lewis Adjustment Index (TLI) and Root Mean Square Error of Approximation (RMSEA). The standardized factor loadings and the determination coefficient (R2) was also estimated.Main resultsA total of 212 clinical scenarios were analyzed. The specified factorial model had the same grouping of elements in four domains as the original version of ANTS. The CFI index and the TLI were 0.99 and the RMSEA reached 0.07 (95% CI 0.06–0.08). All the standardized factor loadings were found to be >0.4. Also, the elements obtained an R2 value that fluctuated between 0.54 and 0.92.ConclusionsThe Spanish version of ANTS is a valid, reliable and a useful tool to assess non-technical skills in Spanish-speaking countries. The applicability of the instrument was comparable to the original setting. The high reliability of ANTS in our setting allows us to propose its use not just in an educational and research setting; it can be used as an assessment tool of non-technical skills.  相似文献   

8.
BackgroundUse of the single-port da Vinci SP robotic platform for various urological procedures has been described by several groups. However, the comparative performance of the SP robot in relation to earlier models such as the da Vinci Xi is still unclear.ObjectiveTo compare intraoperative and short-term postoperative outcomes between the da Vinci Xi and SP robots for patients undergoing radical prostatectomy (RP) in a referral center.Design, setting, and participantsData were prospectively collected for patients undergoing RP from June 2019 to April 2020 in a single center. The da Vinci SP was used for 71 patients and the da Vinci Xi for 875 patients. After propensity score (PS) matching, two groups of 71 patients were selected for the comparative study.InterventionRP via a transperitoneal approach using the same technique steps and anatomy access with both robot consoles.Outcome measurements and statistical analysisA PS analysis was performed using the covariates age, body mass index, Charlson comorbidity index, Sexual Health Inventory for Men score, American Urological Association symptom score, prostate size, prostate-specific antigen levels, Gleason score, D’Amico risk group, and degree of nerve-sparing. Intraoperative performance and short-term functional (continence and potency) and oncological outcomes were compared between the groups.Results and limitationsMedian follow-up was 4.4 mo (interquartile range [IQR] 1.6–7.2) for the SP group and 3.2 mo (IQR 1.6–4.8) for the Xi group (p = 0.2). The median total operative time and median console time were both significantly higher in the SP group, with median differences of 14 min (95% confidence interval [CI] 9–19) and 5 min (95% CI 0–5), respectively. The proportion of patients with blood loss of >100 ml was significantly lower in the SP group (difference of 27%, 95% CI 12–42%). No intra- or postoperative complications were reported in either group. There were no significant differences in pain scores at 6, 12, and 18 h or in positive surgical margin rates between the groups. The SP group had a significantly higher percentage of extraprostatic extension than the Xi group (difference of 16%, 95% CI 4.6–27%). None of the patients experienced biochemical recurrence during follow-up. The difference in continence rates at 45 d between the SP and Xi groups was 11% (95% CI ?5.6% to 28%) and the difference in potency rates at 45 d was ?7.3% (95% CI ?21% to 6.2%). The short-term follow-up for comparison of functional and oncological outcomes is a limitation.ConclusionsDespite differences in trocar placement and technology between the two da Vinci consoles, the SP has satisfactory intraoperative performance compared to the Xi. SP surgery can be performed safely and effectively during the initial learning phase. However, longer-term follow-up is needed to provide further evidence on the impact of SP implementation on functional and oncological outcomes.Patient summaryWe compared intraoperative and short-term postoperative outcomes for patients who underwent radical prostatectomy using two different robots, the da Vinci Xi and the single-port da Vinci SP. We found that operative time was longer for the Single Port console. Studies with long-term follow-up are needed to compare the functional and oncological outcomes.  相似文献   

9.
10.
Objectives: To analyze the incidence of malfunction of the da Vinci robotic system in a single center and to provide potential solutions. Methods: A total of 400 patients underwent da Vinci robotic urological surgery at Taichung Veterans General Hospital in Taichung, Taiwan, from December 2005 to April 2011. Episodes of malfunction of the robotic system were analyzed by period of operation, type of procedure, type of malfunction and management of the event. Results: Overall, 14 cases of malfunction occurred (3.5% of the entire series). Among them, five (1.25%) occurred before the surgery and nine (2.25%) intraoperatively. Operative procedures included radical prostatectomy, bilateral pelvic lymph node dissection, dismembered pyeloplasty, partial nephrectomy, nephroureterectomy, and radical and partial cystectomies. Areas of malfunctions included the robotic arm system and joint (11/14), optical system (1/14), power system and connector (1/14), endoscopic instrument (1/14), and software (1/14). In 10 cases, the failure was recoverable, whereas in four cases there was a critical failure, requiring a conversion to standard laparoscopy in three of them, and the rescheduling of the surgery in one case. Conclusions: The da Vinci robotic system is extremely reliable for use in urology. Malfunction is rare and the risk of critical failure is very low. Managing mechanical failure before or during the surgery is the key to maintaining the safety of patients undergoing robotic surgical procedures.  相似文献   

11.
Leonardo da Vinci's marvellous anatomical drawings have been praised by both artists and medical historians over the centuries. Specific reference is made here to Leonardo's drawings of the act of sexual intercourse. It is shown that his illustrations are not based purely on original observation. Rather, they are an attempt to illustrate and clarify anatomy and physiology as presented in the textbooks of the time.  相似文献   

12.
Anatomical and technical limitations as well as human factors render endoscopic coronary artery bypass surgery difficult. The da Vinci telemanipulator overcomes some of these shortcomings by restoring the dexterity and precision of a distant operator within the confined space in a closed-chest environment. Using the da Vinci system, total endoscopic coronary artery bypass grafting has evolved from a merely experimental surgical approach to a clinically applicable treatment option. Initially exclusively performed on the arrested heart, adjunct technologies such as endoscopic vacuum-assisted stabilizers now allow a single-vessel closed-chest beating heart procedure in selected patients. Despite the technical progress, endoscopic multivessel bypass grafting has yet to be achieved. The development of endoscopically applicable anastomotic devices and heart-positioning devices along with further refinements in telemanipulator technology, better optical systems, and image guided augmented reality scenarios may facilitate endoscopic bypass grafting in the future.  相似文献   

13.
Robotic mitral valve repair: experience with the da Vinci system   总被引:3,自引:0,他引:3  
BACKGROUND: As part of a Food and Drug Administration trial, mitral repairs were performed in 38 patients using the robotic da Vinci surgical system (Intuitive Surgical, Inc, Mountain View, CA). Prospectively, we evaluated safety and efficacy in performing both simple and complex mitral repairs. METHODS: Eligible patients had nonischemic moderate to severe mitral insufficiency. Operative techniques included peripheral cardiopulmonary perfusion, a 4- to 5-cm mini-thoracotomy, transthoracic aortic occlusion, and antegrade blood cardioplegia. Transesophageal echocardiograms were done intraoperatively with three-dimensional reconstructions. Successful repairs were defined as mild or less residual regurgitation. RESULTS: Enhanced three-dimensional visualization of mitral leaflets and the subvalvar apparatus allowed safe, dexterous intracardiac tissue manipulation. All patients had successful valve repairs including quadrangular resections, sliding plasties, and edge-to-edge approximations, as well as both chordal transfers and replacements. There were no operative deaths, strokes, or device-related complications. One patient required valve replacement for hemolysis and 1 was reexplored for bleeding. There were no incisional conversions. Both robotic repair and total operating times decreased significantly from 1.9 +/- 0.1 and 5.1 +/- 0.1 hours (mean +/- standard error of the mean) for the first 19 patients to 1.5 +/- 0.1 (p = 0.002) and 4.4 +/- 0.1 hours (p = 0.04) for the last 19 operations, respectively. Total hospital length of stay for patients was 3.8 +/- 0.6 days. Of all patients, 31 (82%) had a 4-day or less length of stay. Seven patients (18%) had stays between 5 and 9 days (6.4 +/- 1.0). CONCLUSIONS: This study shows that the da Vinci surgical system (Intuitive Surgical, Inc) has few limitations in performing complex valve repairs. Articulated wrist-like instruments and three-dimensional visualization enabled precise tissue telemanipulation. Future robotic design advances and adjunctive suture technologies may promote continuing evolution of robotic cardiac operations.  相似文献   

14.
15.
BACKGROUND: The objective of this study was to compare the efficacy of the da Vinci robotic system using both the three-dimensional view (3D) and two-dimensional (2D) view options with traditional manually assisted laparoscopic techniques in performing standardized exercises. METHODS: To evaluate surgical efficiency in the use of robotically assisted and manual laparoscopic surgery for standardized exercises six, last-year medical students without any surgical experience were selected. The exercises consisted of placing rings over receptacles, grasping a free hanging suture and cutting three pieces of it, running a suture, and performing a surgical knot. Each student performed the exercise twice. The median times needed for completion of the exercises and the median number of errors in performing the tasks were noted. RESULTS: The unexperienced students performed the standardized tasks significantly quicker and with fewer errors when assisted by the da Vinci robot in the 3D optical display mode, as compared with traditional manually assisted laparoscopic surgery. Even when the 2D mode was selected, a significant advantage favoring the da Vinci robotic system was seen both in time and efficacy for most exercises. When the 3D and 2D modes were compared, time differences in favor of the 3D mode remained, but a significant difference in efficacy favoring the 3D mode was seen only in one exercise (exercise 2: suture cutting). CONCLUSIONS: The da Vinci robotic system permits standardized minimal invasive surgical exercises to be performed quicker and more efficiently than traditional minimally invasive techniques. Therefore, with the aid of this robotic system, difficult laparoscopic interventions may become easier to perform, and indications for minimal invasive surgery may be expanded.  相似文献   