首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to assess the efficacy and safety of percutaneous radiofrequency (RF) ablation therapy combined with cementoplasty under computed tomography and fluoroscopic guidance for painful bone metastases. Seventeen adult patients with 23 painful bone metastases underwent RF ablation therapy combined with cementoplasty during a 2-year period. The mean tumor size was 52 × 40 × 59 mm. Initial pain relief, reduction of analgesics, duration of pain relief, recurrence rate of pain, survival rate, and complications were analyzed. The technical success rate was 100%. Initial pain relief was achieved in 100% of patients (n = 17). The mean VAS scores dropped from 63 to 24 (p < 0.001) (n = 8). Analgesic reduction was achieved in 41% (7 out of 17 patients). The mean duration of pain relief was 7.3 months (median: 6 months). Pain recurred in three patients (17.6%) from 2 weeks to 3 months. Eight patients died and 8 patients are still alive (a patient was lost to follow-up). The one-year survival rate was 40% (observation period: 1–30 months). No major complications occurred, but one patient treated with this combined therapy broke his right femur 2 days later. There was transient local pain in most cases, and a hematoma in the psoas muscle (n = 1) and a hematoma at the puncture site (n = 1) occurred as minor complications. Percutaneous RF ablation therapy combined with cementoplasty for painful bone metastases is effective and safe, in particular, for bulky tumors extending to extraosseous regions. A comparison with cementoplasty or RF ablation alone and their long-term efficacies is needed.  相似文献   

2.

Objective

To assess the safety and therapeutic efficacy of a percutaneous radiofrequency (RF) ablation for the hepatocellular carcinoma (HCC) abutting the diaphragm.

Materials and Methods

We retrospectively assessed 80 patients who underwent a percutaneous RF ablation for a single nodular (< 4 cm) HCC over the last four years. Each patient underwent an ultrasound-guided RF ablation using internally cooled electrodes for the first-line treatment. We divided patients into two subgroups based on whether the index tumor was abutting (less than 5 mm) the diaphragm or not: group A (abutting; n = 31) versus group B (non-abutting; n = 49). We compared the two subgroups for complications and therapeutic efficacy using image and the review of medical records. The statistical assessment included an independent t-test, Fisher''s exact test, and chi-square test.

Results

The assessment of the diaphragmatic swelling at CT immediately following the procedure was more severe in group A than group B (mean thickness change:1.44 vs. 0.46 mm, p = 0.00). Further, right shoulder pain was more common in group A than B (p = 0.01). Although minor complications (hemothorax 1 case, pleural effusion 1 case) were noted only in group A, no major thoracic complication occurred in either group. The technical success rate was lower in group A than group B (84% vs. 98%, p = 0.03). As well, the primary and secondary technique effectiveness rates in group A and group B were 90% versus 98% (p = 0.29) and 79% versus 91% (p = 0.25), respectively. The local tumor progression rate was higher in group A than in group B (29% vs. 6%, p = 0.02).

Conclusion

We found that the percutaneous RF ablation for the HCC abutting the diaphragm is a safe procedure without major complications. However, it is less effective with regard to technical success and local tumor control.  相似文献   

3.

Objective

The objective of this study was to evaluate the safety and therapeutic efficacy of percutaneous radiofrequency (RF) ablation for the treatment of hepatocellular carcinomas (HCCs) adjacent to the gallbladder with the use of internally cooled electrodes.

Materials and Methods

We retrospectively assessed 45 patients with 46 HCCs (mean size, 2.2 cm) adjacent to the gallbladder (≤1.0 cm) treated with RF ablation using an internally cooled electrode system. An electrode was inserted into the tumor either parallel (n = 38) or perpendicular (n = 8) to the gallbladder wall. The safety and therapeutic efficacy of the procedures were assessed with clinical and imaging follow-up examinations. Follow-up with the use of CT ranged from four to 45 months (mean, 19 months). The association between variables (electrode direction, electrode type, tumor size, tumor location, lobar location) and the presence of a residual tumor or local tumor progression was also analyzed.

Results

There were no major complications and minor complications were noted in three patients (7%) including one case of vasovagal syncope and two cases of bilomas. Wall thickening of the gallbladder adjacent to the RF ablation zone was noted in 14 patients (41%) as determined on immediate follow-up CT imaging. Wall thickening showed complete disappearance on subsequent follow-up CT imaging. The primary technique effectiveness rate was 96% (44/46) based on one-month follow-up CT imaging. Local tumor progression was noted in six (14%) of 44 completely ablated tumors during the follow-up period. The direction of electrode insertion (perpendicular), tumor size (≥3 cm) and tumor location (a tumor that abutted the gallbladder) were associated with an increased risk of early incomplete treatment. No variable was significantly associated with local tumor progression.

Conclusion

Percutaneous RF ablation of HCCs adjacent to the gallbladder using an internally cooled electrode is a safe and effective treatment. Significant risk factors that lead to early incomplete treatment include tumor size, tumor location and electrode direction.  相似文献   

4.
Aims In this article we present our experience with radiofrequency ablation (RFA) in the treatment of 105 renal tumors. Materials and Methods RFA was performed on 105 renal tumors in 97 patients, with a mean tumor size of 32 mm (11–68 mm). The mean patient age was 71.7 years (range, 36–89 years). The ablations were carried out under ultrasound (n = 43) or CT (n = 62) guidance. Imaging follow-up was by contrast-enhanced CT within 10 days and then at 6-monthly intervals. Multivariate analysis was performed to determine variables associated with procedural outcome. Results Eighty-three tumors were completely treated at a single sitting (79%). Twelve of the remaining tumors were successfully re-treated and a clinical decision was made not to re-treat seven patients. A patient with a small residual crescent of tumor is under follow-up and may require further treatment. In another patient, re-treatment was abandoned due to complicating pneumothorax and difficult access. One patient is awaiting further re-treatment. The overall technical success rate was 90.5%. Multivariate analysis revealed tumor size to be the only significant variable affecting procedural outcome. (p = 0.007, Pearson χ2) Five patients had complications. There have been no local recurrences. Conclusion Our experience to date suggests that RFA is a safe and effective, minimally invasive treatment for small renal tumors.  相似文献   

5.

Objective

To evaluate the morphologic changes of aldosterone-producing adenoma (APA) on computed tomography (CT) before and after radiofrequency ablation (RFA) and to assess the factors that are important in determining successful complete ablation of these tumours.

Method

Between August 2004 and August 2011, 24 consecutive patients with APA undergoing CT-guided percutaneous RFA were identified from our prospective database. The pre-RFA and post-RFA CT appearances of these APAs that showed positive biochemical response were reviewed retrospectively for their 3-dimensional size, tumour volume, and CT attenuation in terms of Hounsfield units (HU). A comparison of these parameters before and after RFA was performed.

Results

In this study, there were 23 APAs in these 24 patients that showed biochemical cure of primary aldosteronism after RFA. When comparing post-RFA to pre-RFA CTs, there was no significant change in tumour size (14.5 mm vs 14.6 mm: P = .83) and tumour volume (1.55 cm3 vs 1.59 cm3; P = .41) after RFA. In nonenhanced CT images, there was no significant reduction in HU from pre-RFA to post-RFA measurements (4.4 HU vs 7.9 HU; P = .52). In contrast-enhanced CTs, there was a significant drop in HU after RFA (from 48.3 HU to 14.7 HU; P = .03). None of the included cases showed a focal region of contrast enhancement to suggest residual tumour.

Conclusion

A change in tumour size, tumour volume, and HU in nonenhanced CT were unreliable in defining radiologic treatment success. Only changes in HU in contrast-enhanced CT was useful in confirming a positive treatment response after RFA for APA.  相似文献   

6.
The purpose of this study was to investigate the relationship between pleural temperature and pneumothorax or pleural effusion after radiofrequency (RF) ablation of lung tumors. The pleural temperature was measured immediately outside the lung surface nearest to the tumor with a fiber-type thermocouple during 25 ablation procedures for 34 tumors in 22 patients. The procedures were divided into two groups depending on the highest pleural temperature: P-group I and P-group II, with highest pleural temperatures of <40°C and ≥40°C, respectively. The incidence of pneumothorax or pleural effusion was compared between the groups. Multiple variables were compared between the groups to determine the factors that affect the pleural temperature. The overall incidence of pneumothorax and pleural effusion was 56% (14/25) and 20% (5/25), respectively. Temperature data in five ablation procedures were excluded from the analyses because these were affected by the pneumothorax. P-group I and P-group II comprised 10 procedures and 10 procedures, respectively. The incidence of pleural effusion was significantly higher in P-group II (4/10) than in P-group I (0/10) (p = 0.043). However, the incidence of pneumothorax did not differ significantly (p = 0.50) between P-group I (4/10) and P-group II (5/10). Factors significantly affecting the pleural temperature were distance between the electrode and the pleura (p < 0.001) and length of the lung parenchyma between the electrode and the pleura (p < 0.001). We conclude that higher pleural temperature appeared to be associated with the occurrence of pleural effusion and not with that of pneumothorax.  相似文献   

7.
Although surgical resection remains the best option as potentially curative therapy for hepatocellular carcinoma, radiofrequency thermal ablation has begun to receive much attention as an effective minimally invasive technique for the local control of unresectable malignant hepatic tumors. Most recent radiofrequency devices equipped with a powerful generator and larger needle electrode permit larger thermal lesions, up to 5 cm in diameter, with a single ablation. In this article, the author reviews the technical developments and early clinical results obtained with radiofrequency ablation techniques.  相似文献   

8.
We report a case of painful perineal metastasis from urinary bladder carcinoma in a 73-years-old woman, treated with CT-guided radiofrequency ablation (RFA). The pain was immediately relieved and follow-up at 1 and 6 months showed total necrosis of the mass. One year later, the patient has no pain and her quality of life is improved.  相似文献   

9.
A 45-year-old male with renal cell carcinoma secondary to von-Hippel Lindau (VHL) disease presented for radiofrequency ablation (RFA) of kidney tumors. Due to his prior history of several partial nephrectomies and limited renal reserve, RFA was chosen because of its relatively nephron-sparing nature. A laser guidance device was used to help guide probe placement in an attempt to reduce procedure time and improve targeting accuracy. The device was successful at guiding needle placement, as both tumors were located with a single pass. Follow-up CT scan confirmed accurate needle placement, showing an area of coagulation necrosis covering the previously seen tumor.  相似文献   

10.
We performed percutaneously radiofrequency (RF) ablation of 5 renal cell carcinomas (mean diameter 26 ± 15 mm) with computed-tomography (CT) fluoroscopic guidance using the transhepatic route. The RF electrode was successfully advanced into all tumors. RF ablation caused one minor complication (small asymptomatic perirenal hematoma); no major complications occurred. The follow-up contrast-enhanced CT images showed no local tumor progression of any tumors in a median period of 10 months (range 3–14 months). In conclusion, it seems that this transhepatic approach is safe and can be an alternative method for electrode insertion during RF ablation of selected renal tumors.  相似文献   

11.
The prognosis of patients with adrenal metastases from hepatocellular carcinoma (HCC) has been poor, and aggressive treatment of these tumors is mandatory to improve patients’ survival. Since adrenalectomy may be difficult to perform after previous surgery of the right liver lobe, other approaches are required to treat the adrenal mass. This report aims at demonstrating the feasibility of CT-guided transhepatic radiofrequency ablation of right adrenal HCC metastases pretreated with chemoembolization in patients unable to undergo surgical resection.  相似文献   

12.
We retrospectively reviewed the imaging of patients after radiofrequency ablation (RFA) of lung metastases performed at our institution to assess the usefulness of ground glass opacification (GGO) margin for the prediction of complete tumor ablation. From January 2004 to March 2007, patients were identified where there was a postprocedure thin collimation scan to allow multiplanar reformatting, either immediately or at 24 h and at least 6 months of imaging follow-up. Thirty-six tumors in 22 patients were identified. The scans were assessed for the presence and width of GGO margin, and minimal and maximal dimensions were measured. A second reviewer, blinded to the outcome of the postprocedure assessment, reviewed the follow-up imaging for recurrence. The recurrence group had larger tumors (p = 0.045) and smaller mean minimal GGO margin width (p = 0.0001). Multivariate binary regression analysis confirmed that the minimal GGO margin was significantly (p < 0.005) associated with tumor recurrence. Receiver operator characteristic curve analysis suggests a cutoff of 4.5 mm for complete tumor ablation. There was substantial agreement (κ = 0.759) between the site of absent GGO margin and the site of tumor recurrence. The point on the tumor surface where there is no GGO margin is likely to be the site of future recurrence. In our experience, a circumferential GGO margin of >5 mm is the minimal margion required to ensure complete tumor ablation.  相似文献   

13.
Purpose To evaluate the feasibility and potential advantages of the radiofrequency ablation of liver tumors using new MRI-compatible semiflexible applicators in a closed-bore high-field MRI scanner. Methods We treated 8 patients with 12 malignant liver tumors of different origin (5 colorectal carcinoma, 2 cholangiocellular carcinoma, 1 breast cancer) under MRI guidance. Radiofrequency ablation (RFA) was performed using 5 cm Rita Starburst Semi-Flex applicators (Rita Medical Systems, Milwaukee, WI, USA) which are suitable for MR- and CT-guided interventions and a 150 W RF generator. All interventions were performed in a closed-bore 1.5 T high-field MRI scanner for MRI-guided RFA using fast T1-weighted gradient echo sequences and T2-weighted ultra-turbo spin echo sequences. Control and follow-up MRI examinations were performed on the next day, at 6 weeks, and every 3 months after RFA. Control MRI were performed as double-contrast MRI examinations (enhancement with iron oxide and gadopentetate dimeglumine). All interventions were performed with the patient under local anesthesia and analgo-sedation. Results The mean diameter of the treated hepatic tumors was 2.4 cm (±0.6 cm, range 1.0–3.2 cm). The mean diameter of induced necrosis was 3.1 cm (±0.4 cm). We achieved complete ablation in all patients. Follow-up examinations over a duration of 7 months (±1.3 months, range 4–9 month) showed a local control rate of 100% in this group of patients. All interventions were performed without major complications; only 2 subcapsular hematomas were documented. Conclusion RFA of liver tumors using semiflexible applicators in closed-bore 1.5 T scanner systems is feasible. These applicators might simplify the RFA of liver tumors under MRI control. The stiff distal part of the applicator facilitates its repositioning.  相似文献   

14.
The aim of this study was to show the feasibility, safety, imaging appearance, and short-term efficacy of image-guided percutaneous radiofrequency ablation (RFA) of adrenal metastases (AM). Seven imaging-guided percutaneous RFA treatments were performed in six patients (two men and four women; mean age, 67.2 years; range, 55–74 years) with six AM who were referred to our institution from 2003 to 2006. One patient was treated twice for recurrence after first treatment. The average diameter of the treated AM was 29 mm (range, 15–40 mm). In all patients, the diagnosis was obtained with CT current protocols in use at our institution and confirmed by pathology with an image-guided biopsy. No major complications occurred. In one patient shortly after initiation of the procedure, severe hypertension was noted; another patient developed post-RFA syndrome. In five of six lesions, there was no residual enhancement of the treated tumor. In one patient CT examination showed areas of residual enhancement of the tumor after treatment. Our preliminary results suggest that imaging-guided percutaneous RFA is effective for local control of AM, without major complications and with a low morbidity rate related to the procedure. Long-term follow-up will need to be performed and appropriate patient selection criteria will need to be determined in future randomized trials.  相似文献   

15.
Purpose  To prospectively evaluate the feasibility, safety, and clinical utility of bone radiofrequency (RF) ablation with real-time monitoring of the spinal canal temperature for the treatment of spinal tumors adjacent to the spinal cord. Materials and Methods  Our Institutional Review Board approved this study. Patients gave informed consent. The inclusion criteria were (a) a painful spinal metastasis and (b) a distance of 1 cm or less between the metastasis and the spinal cord. The thermocouple was placed in the spinal canal under CT fluoroscopic guidance. When the spinal canal temperature reached 45°C, RF application was immediately stopped. RF ablation was considered technically successful when the procedure was performed without major complications. Clinical success was defined as a fall in the visual analogue scale score of at least 2 points. Results  Ten patients with spinal tumors measuring 3–8 cm (mean, 4.9 ± 1.5 cm) were enrolled. The distance between the tumor and the spinal cord was 1–6 mm (mean, 2.4 ± 1.6 mm). All procedures were judged technically successful (100%). The spinal canal temperature did not exceed 45°C in 9 of the 10 patients (90%). In the remaining patient, the temperature rose to 48°C, resulting in transient neural damage, although RF application was immediately stopped when the temperature reached 45°C. Clinical success was achieved within 1 week in all patients (100%). Conclusion  Bone RF ablation with real-time monitoring of the spinal canal temperature is feasible, safe, and clinically useful for the treatment of painful spinal metastases adjacent to the spinal cord.  相似文献   

16.
Purpose To evaluate the feasibility, safety, and technical efficacy of image-guided radiofrequency ablation (RFA) for the treatment of small peripheral renal tumors and to report our early results with this treatment modality. Methods Twenty-two RFA sessions for 18 tumors were performed in 11 patients with renal tumors. Indications included coexistent morbidity, high surgical or anesthetic risk, solitary kidney, and hereditary predisposition to renal cell carcinoma. Ten patients had CT-guided percutaneous RFA performed on an outpatient basis. One patient had open intraoperative ultrasound-guided RFA. Technical success was defined as elimination of areas that enhanced at imaging within the entire tumor. With the exception of one patient with renal insufficiency who required gadolinium-enhanced MRI, the remaining patients underwent contrast-enhanced CT for post-treatment follow-up assessment. Follow-up was performed after 2–4 weeks and then at 3, 6, 12 months, and every 12 months thereafter. Results Fourteen (78%) of 18 tumors were successfully ablated with one session. Three of the remaining four tumors required two sessions for successful ablation. One tumor will require a third session for areas of persistent enhancement. Mean patient age was 72.82 ± 10.43 years. Mean tumor size was 1.95 ± 0.79 cm. Mean follow-up time was 10.91 months. All procedures were performed without any major complications. Conclusions Our early experience with percutaneous image-guided radiofrequency ablation demonstrates it to be a feasible, safe, noninvasive, and effective treatment of small peripheral renal tumors.  相似文献   

17.
肝肿瘤经皮射频切除术后CT表现   总被引:6,自引:0,他引:6  
目的 研究肝肿瘤经皮射频切除术后病灶及周围肝实质的CT表现。材料与方法 回顾性分析32例肝肿瘤患者(原发性肝癌28例,转移性肝癌4例)共40个病灶经皮射频切除术前后CT表现。CT检查采用普通或螺旋CT扫描,后者增强扫描为双期螺旋扫描。结果 术后平扫治疗区为低密度,范围增大,大多数边界不清。增强扫描低密度区边界清晰。29个病灶(肿瘤大小1.5-4.3cm,平均3.1cm)治疗区无强化,11个病灶(肿瘤大小4.9-11.0cm,平均6.4cm)仍见残留癌灶强化。其他征象有:治疗区周围强化,病灶内出血、含气,胸水和腹水。结论 肝肿瘤经皮射频切术后CT检查,特别是增强扫描对评估治疗效果和发现并发症有很大价值。  相似文献   

18.
Ultrasound-guided percutaneous radiofrequency (RF) ablation has become one of the most promising local cancer therapies for both resectable and nonresectable hepatic tumors. Although RF ablation is a safe and effective technique for the treatment of liver tumors, the outcome of treatment can be closely related to the location and shape of the tumors. There may be difficulties with RF ablation of tumors that are adjacent to large vessels or extrahepatic heat-vulnerable organs and tumors in the caudate lobe, possibly resulting in major complications or treatment failure. Thus, a number of strategies have been developed to overcome these challenges, which include artificial ascites, needle track ablation, fusion imaging guidance, parallel targeting, bypass targeting, etc. Operators need to use the right strategy in the right situation to avoid the possibility of complications and incomplete thermal tissue destruction; with the right strategy, RF ablation can be performed successfully, even for hepatic tumors in high-risk locations. This article offers technical strategies that can be used to effectively perform RF ablation as well as to minimize possible complications related to the procedure with representative cases and schematic illustrations.  相似文献   

19.

Objective

To prospectively evaluate the safety and short-term therapeutic efficacy of switching monopolar radiofrequency ablation (RFA) with multiple electrodes to treat medium-sized (3.1-5.0 cm), hepatocellular carcinomas (HCC).

Materials and Methods

In this prospective study, 30 patients with single medium-sized HCCs (mean, 3.5 cm; range, 3.1-4.4 cm) were enrolled. The patients were treated under ultrasonographic guidance by percutaneous switching monopolar RFA with a multichannel RF generator and two or three internally cooled electrodes. Contrast-enhanced CT scans were obtained immediately after RFA, and the diameters and volume of the ablation zones were then measured. Follow-up CT scans were performed at the first month after ablation and every three months thereafter. Technical effectiveness, local progression and remote recurrence of HCCs were determined.

Results

There were no major immediate or periprocedural complications. However, there was one bile duct stricture during the follow-up period. Technical effectiveness was achieved in 29 of 30 patients (97%). The total ablation time of the procedures was 25.4 ± 8.9 minutes. The mean ablation volume was 73.8 ± 56.4 cm3 and the minimum diameter was 4.1 ± 7.3 cm. During the follow-up period (mean, 12.5 months), local tumor progression occurred in three of 29 patients (10%) with technical effectiveness, while new HCCs were detected in six of 29 patients (21%).

Conclusion

Switching monopolar RFA with multiple electrodes in order to achieve a sufficient ablation volume is safe and efficient. This method also showed relatively successful therapeutic effectiveness on short-term follow up for the treatment of medium-sized HCCs.  相似文献   

20.
Liver tumour ablation nowadays represents a routine treatment option for patients with primary and secondary liver tumours. Radiofrequency ablation and microwave ablation are the most widely adopted methods, although novel techniques, such as irreversible electroporation, are quickly working their way up. The percutaneous approach is rapidly gaining popularity because of its minimally invasive character, low complication rate, good efficacy rate, and repeatability. However, matched to partial hepatectomy and open ablations, the issue of ablation site recurrences remains unresolved and necessitates further improvement. For percutaneous liver tumour ablation, several real-time imaging modalities are available to improve tumour visibility, detect surrounding critical structures, guide applicators, monitor treatment effect, and, if necessary, adapt or repeat energy delivery. Known predictors for success are tumour size, location, lesion conspicuity, tumour-free margin, and operator experience. The implementation of reliable endpoints to assess treatment efficacy allows for completion-procedures, either within the same session or within a couple of weeks after the procedure. Although the effect on overall survival may be trivial, (local) progression-free survival will indisputably improve with the implementation of reliable endpoints. This article reviews the available needle navigation techniques, evaluates potential treatment endpoints, and proposes an algorithm for quality control after the procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号