共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of medical engineering & technology》2013,37(2):88-90
Positron-emitting radionuclides are being used more and more in nuclear medicine. This paper describes a high energy collimator suitable for imaging at 511 keV, the energy emitted by these radionuclides, for use with the Baird Corporation's System 77. 相似文献
2.
Hybrid PET gamma cameras with coincidence detection electronics are commonly equipped with parallel slat collimators in order to reduce detection of singles and scattered photons, and create a pseudo-2D imaging geometry. The objective of this work was to survey a broad range of parallel slat collimator designs using a series of Monte Carlo simulated PET acquisitions. Collimator properties including septal height, septal thickness and pitch were independently examined over a wide range of values. Simulations were performed for hybrid PET imaging of a long cylindrical phantom uniformly filled with water and radioactivity. The performance for each collimator design was evaluated in terms of the trues-to-singles ratio, scatter fraction, and noise equivalent count rate for a wide range of camera trigger rates. Results indicate that increasing septal height offers the biggest performance gain. Septal thickness should be at least 0.5 mm, and should be optimized in conjunction with pitch to obtain the best performance. This survey provides the groundwork necessary for optimizing slat collimators, and provides a starting point for investigating new slat collimator designs. 相似文献
3.
Zeng GL Gagnon D Matthews CG Kolthammer JA Radachy JD Hawkins WG 《Medical physics》2002,29(7):1406-1412
A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted planar integrals of the object. This paper describes the development of an approximate three-dimensional image reconstruction algorithm for a rotating/spinning slat collimator. This algorithm is in filtered backprojection form. Computer simulations were performed to verify the effectiveness of the algorithm. 相似文献
4.
5.
Boisson F Bekaert V El Bitar Z Wurtz J Steibel J Brasse D 《Physics in medicine and biology》2011,56(5):1471-1485
Some current investigations based on small animal models are dedicated to functional cerebral imaging. They represent a fundamental tool to understand the mechanisms involved in neurodegenerative diseases. In the radiopharmaceutical development approach, the main challenge is to measure the radioactivity distribution in the brain of a subject with good temporal and spatial resolutions. Classical SPECT systems mainly use parallel hole or pinhole collimators. In this paper we investigate the use of a rotating slat collimator system for small animal brain imaging. The proposed prototype consists of a 64-channel multi-anode photomultiplier tube (H8804, Hamamatsu Corp.) coupled to a YAP:Ce crystal highly segmented into 32 strips of 0.575 × 18.4 × 10 mm(3). The parameters of the rotating slat collimator are optimized using GATE Monte Carlo simulations. The performance of the proposed prototype in terms of spatial resolution, detection efficiency and signal-to-noise ratio is compared to that obtained with a gamma camera equipped with a parallel hole collimator. Preliminary experimental results demonstrate that a spatial resolution of 1.54 mm can be achieved with a detection efficiency of 0.012% for a source located at 20 mm, corresponding to the position of the brain in the prototype field of view. 相似文献
6.
This paper discusses the use of small pixels in a spinning CdZnTe single photon emission computed tomography (SPECT) camera that is mounted with a parallel slat collimator. In a conventional slat collimation configuration, there is a detector pixel between two adjacent collimator slats. In our design, the pixel size is halved. That is, there are two smaller pixels to replace a regular pixel between two adjacent slats while the collimator remains unchanged. It has an advantage over our older design that uses tilted slats. In order to acquire a complete data set the tilted-slat collimator must spin 360 degrees at each SPECT view while the proposed design requires only 180 degrees at each SPECT view. Computer simulations and phantom experiments have been carried out to investigate the performance of the small-pixel configuration. It is observed that this design has the potential to increase the spatial resolution of the detector while keeping photon counts the same. 相似文献
7.
In computerised gamma camera imaging the projections are readily obtained in digital form, and the number of picture elements may be relatively few. This condition makes emission techniques suitable for ectomography--a tomographic technique for directly visualising arbitrary sections of the human body. The camera rotates around the patient to acquire different projections in a way similar to SPECT. This method differs from SPECT, however, in that the camera is placed at an angle to the rotational axis, and receives two-dimensional, rather than one-dimensional, projections. Images of body sections are reconstructed by digital filtration and combination of the acquired projections. The main advantages of ectomography--a high and uniform resolution, a low and uniform attenuation and a high signal-to-noise ratio--are obtained when imaging sections close and parallel to a body surface. The filtration eliminates signals representing details outside the section and gives the section a certain thickness. Ectomographic transverse images of a line source and of a human brain have been reconstructed. Details within the sections are correctly visualised and details outside are effectively eliminated. For comparison, the same sections have been imaged with SPECT. 相似文献
8.
9.
This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 degrees and stops at N positions uniformly distributed over this 180 degrees. At each stop, the device spins on its own axis 180 degrees and acquires measurements at M positions uniformly distributed over this 180 degrees. For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative algorithms, compared with the situation when a constant dwell-time profile is used. 相似文献
10.
A single photon emission computed tomography (SPECT) rotating slat collimator with strip detector acquires distance-weighted plane integral data, along with the attenuation factor and distance-dependent detector response. In order to image a 3D object, the slat collimator device has first to spin around its axis and then rotate around the object to produce 3D projection measurements. Compared to the slice-by-slice 2D reconstruction for the parallel-hole collimator and line integral data, a more complex 3D reconstruction is needed for the slat collimator and plane integral data. In this paper, we propose a 3D RBI-EM reconstruction algorithm with spherically-symmetric basis function, also called 'blobs', for the slat collimator. It has a closed and spherically symmetric analytical expression for the 3D Radon transform, which makes it easier to compute the plane integral than the voxel. It is completely localized in the spatial domain and nearly band-limited in the frequency domain. Its size and shape can be controlled by several parameters to have desired reconstructed image quality. A mathematical lesion phantom study has demonstrated that the blob reconstruction can achieve better contrast-noise trade-offs than the voxel reconstruction without greatly degrading the image resolution. A real lesion phantom study further confirmed this and showed that a slat collimator with CZT detector has better image quality than the conventional parallel-hole collimator with NaI detector. The improvement might be due to both the slat collimation and the better energy resolution of the CZT detector. 相似文献
11.
12.
Smeets J Roellinghoff F Prieels D Stichelbaut F Benilov A Busca P Fiorini C Peloso R Basilavecchia M Frizzi T Dehaes JC Dubus A 《Physics in medicine and biology》2012,57(11):3371-3405
Treatments delivered by proton therapy are affected by uncertainties on the range of the beam within the patient, requiring medical physicists to add safety margins on the penetration depth of the beam. To reduce these margins and deliver safer treatments, different projects are currently investigating real-time range control by imaging prompt gammas emitted along the proton tracks in the patient. This study reports on the feasibility, development and test of a new concept of prompt gamma camera using a slit collimator to obtain a one-dimensional projection of the beam path on a scintillation detector. This concept was optimized, using the Monte Carlo code MCNPX version 2.5.0, to select high energy photons correlated with the beam range and detect them with both high statistics and sufficient spatial resolution. To validate the Monte Carlo model, spectrometry measurements of secondary particles emitted by a PMMA target during proton irradiation at 160 MeV were realized. An excellent agreement with the simulations was observed when using subtraction methods to isolate the gammas in direct incidence. A first prototype slit camera using the HiCam gamma detector was consequently prepared and tested successfully at 100 and 160 MeV beam energies. Results confirmed the potential of this concept for real-time range monitoring with millimetre accuracy in pencil beam scanning mode for typical clinical conditions. If we neglect electronic dead times and rejection of detected events, the current solution with its collimator at 15 cm from the beam axis can achieve a 1-2 mm standard deviation on range estimation in a homogeneous PMMA target for numbers of protons that correspond to doses in water at the Bragg peak as low as 15 cGy at 100 MeV and 25 cGy at 160 MeV assuming pencil beams with a Gaussian profile of 5 mm sigma at target entrance. 相似文献
13.
A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm)showing good imaging of 99Tcm radionuclide distributions and comfirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area greater than or approximately equal to 1 m2, a quantum efficiency of 15% and a spatial resolution approximately 3 mm, to be applied in whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronic industry. This apparatus is covered by patent applcation number 26595/77. 相似文献
14.
Preliminary validation of the opposing view method for quantitative gamma camera imaging 总被引:3,自引:0,他引:3
We perform gamma camera imaging to generate data for estimation of internal radiation dose in our radioimmunotherapy candidates. Because of the inability of single photon emission computed tomography (SPECT) to account for patient attenuation variability without serious error, quantitative planar imaging was performed to estimate the radioactive content of normal organs. We undertook the following studies to further validate this method. A realistic fillable human phantom was used to determine the accuracy of I-131 filled organ estimation. A transmission scan of the unfilled phantom was produced with an I-131 filled flat flood source. Anterior and posterior planar images of the filled organs were acquired with region of interest determination of the activity in the organ. Correction by the attenuation factor and a camera calibration factor yielded the MBq in the organ. The procedure was also performed in a simple phantom. Three dogs were imaged and sacrificed to validate the technique in vivo. A high degree of accuracy in estimation of organ radioactive content was found to be present using the phantom and dog models. Use of this method requires further validation but provides a solid basis for estimation of internal radiation dosimetry in radioimmunotherapy planning. 相似文献
15.
16.
17.
We assessed improvements in performance in detection and estimation tasks due to a novel brain single photon computed tomography collimator. Data were acquired on the CeraSPECT scanner using both new and standard collimators. The new variable focusing collimator SensOgrade samples the projections unequally, with central regions more heavily represented, to compensate for attenuation of counts from central brain structures. Furthermore, it utilizes more of the cylindrical crystal surface. Two phantom studies were performed. The first phantom was a 21-cm-diameter cylindrical background containing nine spheres ranging from 0.5 to 5 cm3 in volume. 99mTc sphere to background activity ratio was 10:1. Twenty-nine 10-min datasets were acquired with each collimator. The second phantom was the Radiology Support Devices (Long Beach, CA) striatal phantom with striatal-background ratios of 10:1 on the left and 5:1 on the right. Twenty-nine 4-min datasets were acquired with each collimator. Perfusion imaging using 99mTc-HMPAO was also performed in three healthy volunteers using both collimators under identical simulations. Projections were reconstructed by filtered backprojection with an unwindowed ramp filter. The nonprewhitening matched filter signal-to-noise ratio (NPW-SNR) was computed as a surrogate for human performance in detecting spherical lesions. Sphere activity concentration, radius, and location coordinates were simultaneously estimated by fitting images to an assumed model using an iterative nonlinear algorithm. Resolution recovery was implicit in the estimation procedure, as the point spread function was incorporated into the model. NPW-SNR for sphere detection was 1.5 to 2 times greater with the new collimator; for the striatal phantom the improvement in SNR was 54%. The SNR for estimating sphere activity concentration improved by 46 to 89% for spheres located more than 5 cm from the phantom center. Images acquired with the standard collimator were too noisy in the central regions to allow estimation of sphere activity. In 99mTc-HMPAO human studies, SNR was improved by 21 to 41% in the cortex, 66% in the basal ganglia, and 74% in the thalamus. The new collimator leads to substantially improved detection and estimation performance throughout the brain. The higher sensitivity will be particularly important for dynamic imaging. 相似文献
18.
In order to relate the performance of the human observer to the objective specifications of a gamma camera system, images of a test object were taken under various conditions that could be expected to cause changes in resolution. Observers were asked to put the images in the order of increasing/decreasing sharpness. For the same physical conditions, objective measurements were made from which the resolution parameters FWHM and FWTM could be derived. By looking for significant differences in ordering of the images, it was possible to show that, within the limitations of the specific system investigated, a fractional change in FWHM of about 10% caused a significant change in image quality. Further experiments to test the universality of this figure are suggested. 相似文献
19.
20.