共查询到20条相似文献,搜索用时 11 毫秒
1.
《The Journal of arthroplasty》2023,38(2):335-340
BackgroundRevision of both femoral and tibial components of a total knee arthroplasty (TKA) for aseptic loosening has favorable outcomes. Revision of only one loose component with retention of others has shorter operative time and lower cost; however, implant survivorship and clinical outcomes of these different operations are unclear.MethodsBetween January 2009 and December 2019, a consecutive cohort of revision TKA was reviewed. Univariate and multivariable analyses were used to study correlations among factors and surgical related complications, time to prosthesis failure, and functional outcomes (University of California Los Angeles, Knee Society functional, knee osteoarthritis and outcome score for joint replacement, Veterans RAND 12 (VR-12) physical, and VR-12 mental).ResultsA total of 238 patients underwent revision TKA for aseptic loosening. The mean follow-up time was 61 months (range 25 to 152). Ten of the 105 patients (9.5%) who underwent full revision (both femoral and tibial components) and 18 of the 133 (13.5%) who underwent isolated revision had subsequent prosthesis failure [Hazard ratio (HR) 0.67, P = .343]. The factor analysis of type of revision (full or isolated revision) did not demonstrate a significant difference between groups in terms of complications, implant failures, and times to failure. Metallosis was related to early time to failure [Hazard ratio 10.11, P < .001] and iliotibial band release was associated with more complications (Odds ratio 9.87, P = .027). Preoperative symptoms of instability were associated with the worst improvement in University of California Los Angeles score. Higher American Society of Anesthesiologists status and higher Charlson Comorbidity Index were related with worse VR-12 physical (?30.5, P = .008) and knee osteoarthritis and outcome score for joint replacement (?4.2, P = .050) scores, respectively.ConclusionIsolated and full component revision TKA for aseptic loosening does not differ with respect to prosthesis failures, complications, and clinical results at 5 years. Poor American Society of Anesthesiologists status, increased comorbidities, instability, and a severe bone defect are related to worse functional improvement.Level of evidenceIII, cohort with control. 相似文献
2.
Robert W. Tracey Faisal Akram Craig J. Della Valle Scott M. Sporer Richard A. Berger Tad L. Gerlinger 《The Journal of arthroplasty》2021,36(7):2536-2540
BackgroundTibial component loosening is one of the most common modes of failure in contemporary total knee arthroplasty (TKA). Limited literature is available on the outcomes of isolated tibial revision with retention of the cruciate retaining (CR) femoral component. The purpose of this study was to determine the results of isolated tibial revisions in CR TKA.MethodsWe identified 135 patients who underwent an isolated tibial revision after a primary CR TKA from our institutional registry between January 2007 and January 2017. The mean time between the primary and revision was 2.9 years (range 0.1-15.4). Revision with a press-fit stem was performed in 79 patients and 56 patients were revised with a fully cemented stem. Patients were evaluated at a minimum of two years using Knee Society Score, Knee Injury and Osteoarthritis Score for Joint Replacement, and radiography. Implant survivorship was determined using Kaplan-Meier survival analysis.ResultsAt a mean follow-up of 5.1 years, there were six (4.4%) repeat revisions: three for periprosthetic infection (2.2%), two for instability (1.5%), and one for a fractured tibial stem (0.7%). The mean Knee Society Score and Knee Injury and Osteoarthritis Score for Joint Replacement increased from 51.6 and 56.1 preoperatively to 90.1 and 89.7 after surgery (P < .001). Survivorship free of repeat revision for any cause was 93.3% at 5 years, and aseptic revision survivorship was 95.8% at 5 years. No implants were radiographically loose.ConclusionIn patients with isolated tibial loosening and a well-fixed and well-positioned CR femoral component, isolated tibial revision provides excellent early to midterm implant survivorship and clinical outcomes with a low risk of instability and recurrent tibial loosening. 相似文献
3.
Several reports document high failure rates of metal-backed patellar components, but few report the outcome of revising these components to all-polyethylene, cemented implants. At a mean 87.2-month follow-up, we describe a series of 36 patients (40 knees) who underwent isolated metal-backed patellar revision to a cemented, all-polyethylene patellar component. After the patellar revision, 5 patients (6 knees) underwent additional surgery, but no patellar components required revision. The additional surgeries were performed at an average of 77.6 months after patellar revision and included 3 tibial insert exchanges for polyethylene wear, 2 revisions of femoral and tibial components for osteolysis, and 1 realignment procedure for recurrent subluxation of the patella. We conclude that revision of a failed metal-backed patellar component to a cemented, all-polyethylene patella is a durable, successful procedure. 相似文献
4.
《The Journal of arthroplasty》2020,35(4):1130-1136
BackgroundThe aim of this meta-analysis and systematic review is to estimate re-revision rates due to aseptic loosening of retained acetabular components after revision total hip arthroplasty.MethodsPubMed, EMBASE, Cochrane Library, and Web of Science were searched until June 11, 2018. Data were extracted by 2 independent investigators and consensus was reached with the involvement of a third investigator. Rates of re-revision due to aseptic loosening from 6 studies were aggregated using random effects model after a logit transformation and were grouped by study and population level characteristics.ResultsAn assessment of the re-revision rates of retained acetabular components due to aseptic loosening in revision total hip arthroplasty was reported in 6 studies involving 669 cases. The pooled re-revision rate was 12.6% (95% confidence interval 8.4-18.4) with a mean study follow-up of 8.6 years. The rate of re-revision due to aseptic loosening of retained acetabular components was 6.8% (95% confidence interval 3.4-13.3). In the univariate meta-regression analysis, mean age at index revision surgery was significantly associated with the rate of re-revision due to aseptic loosening (R2 = 99.98%, P < .0001).ConclusionBased on this exploratory analysis, revision hip procedures with retentions of well-fixed acetabular components generally have a low risk of failure during mid-term to long-term follow-ups. 相似文献
5.
Adrian D. Hinman Heather A. Prentice Elizabeth W. Paxton Matthew P. Kelly 《The Journal of arthroplasty》2021,36(5):1577-1583
BackgroundModular tibial stem extensions in total knee arthroplasty (TKA) are designed to reduce the risk of aseptic loosening of the tibial base plate. However, these implants add significant cost and an evaluation of their effectiveness in reducing this risk of loosening has not been studied in a large cohort. We sought to evaluate modular tibial stem utilization in primary TKA.MethodsWe conducted a cohort study using our integrated healthcare system’s Total Joint Replacement Registry. Patients who underwent cemented primary TKA were identified (2009-2019). Propensity scores were used to 1:1 match patients without to those with a stem extension. Cox proportional-hazards regression was used to evaluate the risk for revision due to aseptic loosening.ResultsTen thousand four hundred seventy six TKA with a modular tibial stem were matched to 10,476 TKA without a tibial stem. Stem utilization associated with a lower risk of revision for loosening across all postoperative follow-up (hazard ratio = 0.38, 95% confidence interval = 0.17-0.85).ConclusionIn a matched cohort study, we observed presence of a stem extension was associated with a lower risk of revision for aseptic loosening. Further study to identify specific risk factors for aseptic loosening and confirm the findings presented here are warranted.Level of EvidenceLevel III. 相似文献
6.
Kevin A. Sonn Evan R. Deckard Abdul R. Aasar Lily K. Wolf R. Michael Meneghini 《The Journal of arthroplasty》2021,36(6):2116-2120
BackgroundDiagnostic injections are commonly utilized in the workup of painful total knee arthroplasties (TKA), particularly when the diagnosis remains unclear. However, current literature provides limited evidence regarding the utility and prognostic capability of anesthetic injections in this scenario. This study sought to establish the role of diagnostic injections in predicting successful revision TKA.MethodsA retrospective review was conducted on 144 consecutive aseptic revision TKAs receiving diagnostic anesthetic injections. Instability (57.6%) and aseptic loosening (33.3%) comprised most revision etiologies. Patient-reported percentage pain relief after the injection was statistically correlated with KOOS JR, Knee Society Score, UCLA Activity Level, and satisfaction scores.ResultsAbout 74.3% (107/144) of revision TKAs reported >50% pain relief after injection. There were no differences in pain relief based on revision indication (P = .841). Improvement from preoperative activity level was greater in the >50% pain relief group (P = .024). Four-month patient satisfaction did not differ between patients who reported >50% and ≤50% pain relief (67% vs. 66%, P = .130). About 64% of patients who reported >50% pain relief were satisfied at minimum 1-year follow-up, compared with only 47% of those who reported ≤50% pain relief after diagnostic injection (P < .001).ConclusionStudy results show that patients reporting >50% pain relief after diagnostic injection have improvements in activity level and maintain greater satisfaction at minimum 1-year than those reporting ≤50% pain relief. Expectations for improvement after revision TKA should be tempered if diagnostic anesthetic injection yields minimal subjective pain relief. 相似文献
7.
Ioannis P. Stathopoulos Kalliopi I. Lampropoulou-Adamidou John A. Vlamis George P. Georgiades George C. Hartofilakidis 《The Journal of arthroplasty》2014
The purpose of the present study was to evaluate the long-term outcome of the unrevised part in one-component total hip arthroplasty revision (index operation). Forty-four patients (46 hips) with a mean age of 58 years at the time of the index operation were included. At the final follow-up, 4 of the 19 (21%) unrevised acetabular components and 6 of the 27 (22%) unrevised femoral components were subsequently revised at a mean time of 14 and 11 years from the index operation, and 22 and 24 years from the primary operation, respectively. We concluded that revision of a stable component is not justifiable on the basis of its long duration in use or non-ideal position or possible loosening on radiographs. 相似文献
8.
Lawrence H. Goodnough Andrea K. Finlay James I. Huddleston Stuart B. Goodman William J. Maloney Derek F. Amanatullah 《The Journal of arthroplasty》2018,33(3):882-886
Background
Obesity affects millions of patients in the United States and is associated with several complications after total hip arthroplasty (THA). The effect of obesity on the rate and mode of primary THA failure remains poorly understood, especially given other potentially confounding patient characteristics. We hypothesized that, among patients with a failed primary THA, obesity is independently associated with aseptic loosening and a higher rate of early revision.Methods
Six hundred eighty-four consecutive cases with failed THA referred to a single academic center for revision during a 10-year period were retrospectively reviewed. Multivariate logistic regression analysis was used to test the independent association between obesity and the timing as well as cause of THA failure.Results
The rate of primary THA failure before 5 years was 48.8% in obese and 37.1% in nonobese patients (odds ratio [OR] = 1.57, P = .010). Primary THA failure before 5 years was more likely with increasing body mass index (BMI) (BMI: 35-40 kg/m2, OR = 2.31, P = .008; BMI >40 kg/m2, OR = 2.51, P = .049). The rate of primary THA failure for aseptic loosening before 5 years was 30% in obese and 18% in nonobese patients (OR = 1.88, P = .023). Obesity was not a risk for revision for infection, whereas an American Society of Anesthesiologists class ≥3 was independently associated with primary THA failure for infection (OR = 2.33, P < .001).Conclusion
Among patients with a failed THA, comorbidities may account for the risk of revision due to infection in obese patients. Obesity is independently associated with early primary THA failure for aseptic loosening. 相似文献9.
《Acta orthopaedica》2013,84(1-6):833-839
In a preliminary report concerning 104 Monk arthroplasties satisfactory results were found within an observation time of 1.6 years (Hansen & Rechnagel 1977). However an early tendency for aseptic loosening was recorded. At a follow-up of the same patients after 5 years it was found that 17 patients, with their primary prostheses in place, had died. of the remaining 86 prostheses not less than 50 per cent had been removed because of loosening causing symptoms. Furthermore at re-examination of 39 patients with 43 of the primary prostheses still in situ radiological and clinical evidence of progressive aseptic loosening was present.The aetiology of the loosening is discussed and it is suggested that wear of the polyethylene cap plays an important role. It is concluded that the “soft top” Monk prosthesis cannot be recommended for replacement arthroplasty of the hip. 相似文献
10.
In the evaluation of patients with a persistently painful total hip arthroplasty establishing an accurate diagnosis is paramount in the selection of a successful treatment regimen. It is unknown whether synovial analysis might differentiate aseptic loosening from other causes of failure. A physiological basis exists to suggest that aseptic loosening might be a process of non-segmented leukocytes. The objective of this study was to determine if the synovial fluid differential cell count might aid in the diagnosis of aseptic loosening. A retrospective chart review of all patients who had undergone revision hip arthroplasty with pre-operative or intra-operative aspiration results was performed. Aseptic loosening was defined as gross intraoperative movement in the absence of infection. From these results Relative-Operating Characteristic (ROC) curves were created, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. A diagnosis of aseptic loosening was established in 76 of the 253 hips. The ROC curves indicated that lymphocyte count does have utility in the diagnosis of aseptic loosening. If an aspirate has a combination of fewer than 2500 WBCs (sensitivity 93%, specificity 42%, NPV 94%, accuracy 57%) or more than 10% lymphocytes (sensitivity 86%, specificity 42%, NPV 87%, accuracy 55%) then the sensitivity for aseptic loosening is 96%, the specificity is 33%, the NPV is 95% and the accuracy is 52%. In patients with painful total hip arthroplasties in whom infection has been excluded, aspiration data can be a useful adjunct in the diagnosis of aseptic loosening. In aspirates with neither a WBC cell count of less than 2500 nor a lymphocyte cell count of greater than 10% aseptic loosening can be effectively “ruled out” as fewer than 5% of these patients will have aseptic loosening. While non-specific, aspirate differential can be useful to “rule-out” aseptic loosening with a sensitivity and negative predictive value well exceeding that of standard radiographs. 相似文献
11.
Sergio Romagnoli Matteo Marullo Michele Corbella Enrico Zero Andrea Parente Marco Bargagliotti 《The Journal of arthroplasty》2021,36(3):1080-1086
BackgroundRevision of a failed total hip arthroplasty (THA) poses technical challenges. The use of primary stems for revision can be advantageous for maintaining bone stock and reducing complications: small case series have reported promising results in the short-term to mid-term follow-up. The aim of this study was to evaluate the long-term clinical and functional results and survivorship of a consecutive series of THA femoral component revisions using a conical primary cementless stem (PCS).MethodsNinety-four stem revisions with a preoperative Paprosky I or II defect were analyzed at an average follow-up of 12.7 ± 5.4 years. Aseptic loosening was the reason for revision in 92.5% of cases. Twenty patients were lost to follow-up. Two subgroups were created: Group 1 (n = 59) underwent isolated stem revision; Group 2 (n = 15) underwent complete THA revision. All were evaluated preoperatively and postoperatively based on the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Index (WOMAC) score, and the visual analog scale for pain (VAS). Residual trochanteric pain and length discrepancies were recorded. Radiographic evaluation included signs of osteolysis, subsidence, loosening, and heterotopic ossification.ResultsPCS survivorship was 100% at 5 years and 95.9% at 10 years. Overall, significant postoperative improvements (P < .01) were observed on the HHS (44.3 vs 86.9), WOMAC (42.8 vs 82.8), and VAS (7.0 vs 3.0). Postoperative scores on all scales were higher for Group 1 (P < .01). Three patients (4.1%) underwent further stem revision. Demarcation lines (1 mm) were found in 12 (16.2%) patients and significant heterotopic ossifications in 22 (29.7%).ConclusionThe use of PCS for stem revision in failed THA with a limited femoral bone defect is a reliable option for both isolated stem revision and concomitant cup revision in well-selected patients. 相似文献
12.
《The Journal of arthroplasty》2021,36(9):3174-3180
BackgroundThe objective of this study was to describe the incidence of aseptic loosening (AL) of cemented stem distal femoral replacements (DFR) and to identify modifiable risk factors for its development.MethodsA retrospective review was performed of 245 consecutive primary, cemented stem DFRs implanted at a single institution over a 40-year period. The primary outcome was revision surgery for AL. A multivariate analysis was performed to identify risk factors for AL. Radiographs were reviewed to identify stem tip location, which was defined as diaphyseal or metaphyseal. Implant survival to AL was compared using Kaplan-Meier analysis.ResultsAL and structural failure were the most common causes of implant failure (incidence 11.8%, 29/245). Younger age (P = .002), male sex (P = .01), longer resection length (P = .04), and nonmodular implants (P = .002) were all significantly associated with AL. After 1:1 matching, stem tip location in metaphyseal bone was independently associated with AL (P = .04). 36% (9/25) of implants that loosened had a stem tip located in the metaphysis vs only 8% (2/25) of implants that did not fail. 30-year survival to AL was lower for implants with a metaphyseal stem tip than implants with a diaphyseal stem tip (22.7% vs 47.6%; P = .11).ConclusionA stem tip location in metaphyseal bone is associated with diminished survival to AL. When templating before DFR, stem tip location can assist in identifying high-risk reconstructions that may benefit from alternative or supplemental fixation techniques to prevent the development of AL. 相似文献
13.
Cameron M. Beck Brian I. Nwannunu Kari J. Teigen Russell A. Wagner 《The Journal of arthroplasty》2021,36(2):739-743
BackgroundThe decision as to whether or not to resurface the patella in revision total knee arthroplasty (TKA) is affected by the amount of patellar bone stock remaining; however, the impact of the cancellous bone status on patellar component fixation has not been studied. Therefore, we conducted a biomechanical study of patellar component fixation with varying degrees of cancellous bone loss.MethodsSixty pairs of cadaveric patellae were randomly assigned between 3 groups and prepared in similar manner to a TKA with the standard 3-hole configuration. A control patella and an experimental patella were designated in each pair. To simulate bone loss in the experimental patellae, 1, 2, and 3 of the standard drill holes were uniformly enlarged to 12 mm in group 1, group 2, and group 3, respectively. Afterward, an all-polyethylene patellar component was cemented to each patella, as done intraoperatively. Patellar components were then sheared off using a materials testing system. The resulting mean offset yield force was analyzed within each group using paired t-tests.ResultsThe mean offset yield force for the control patellae was greater than the experimental patellae in group 1. In groups 2 and 3, the experimental patellae produced a greater mean offset yield force than the control patellae. Comparison within each group did not demonstrate a statistically significant difference.ConclusionBone loss with enlargement of the patellar fixation holes, as is frequently seen in revision TKA, with holes up to 12 mm, does not significantly decrease patellar component fixation shear strength in this biomechanical cadaveric study. 相似文献
14.
《The Journal of arthroplasty》2022,37(2):330-335
BackgroundThe purpose of this study is to evaluate the survivorship and radiographic outcomes of a single design of metaphyseal cone used in conjunction with short cemented stems.MethodsA retrospective analysis was conducted of revision total knee arthroplasty (rTKA) patients (June 2015 to December 2017) using porous titanium femoral or tibial cones in conjunction with short cemented stems (50-75 mm). Minimum follow-up was 2 years. Survivorship, complications, and a modified Knee Society Radiographic score were analyzed.ResultsForty-nine rTKAs were included in the study (12 femoral cones, 48 tibial cones). Varus-valgus constraint was used in 28 (57%) and a hinged bearing was used in 3 (6%) of these constructs. The majority were index rTKAs of primary components (86%), performed for aseptic loosening (51%) and reimplantation following staged treatment for infection (37%). Median follow-up was 39 months (range 25-58). Using a modified Knee Society Radiographic score, all constructs were classified as stable. Postoperatively, 4 rTKAs were complicated by recurrent infection (8%), periprosthetic fracture 2 (4%), and superficial wound infection 1 (2%). Seven rTKAs (14%) required reoperation. The majority of reoperations (4 rTKAs) were debridement and irrigation with implant retention for infection. Metaphyseal cone constructs with short cemented stems demonstrated 100% survivorship free of revision for aseptic loosening without evidence of radiographic loosening in any case.ConclusionOur results demonstrate excellent outcomes with the use of metaphyseal cones with short cemented stems at mid-term follow-up. This construct avoids the use of long-stem fixation with the associated extraction difficulty, end of stem pain, and potential for malposition at the joint line.Level of EvidenceIV, Case Series. 相似文献
15.
《The Journal of arthroplasty》2022,37(8):1494-1500
Aseptic loosening is a common cause of revision total hip arthroplasty (rTHA), and with the rising number of primary THAs, revisions for aseptic loosening represent a significant burden for arthroplasty surgeons. Aseptic loosening remains a diagnostic and management challenge. Loosening can occur as a result of inadequate initial fixation, mechanical loss of fixation over time, or a biological loss of fixation over time. However, in most cases, etiology is multifactorial, involving all 3 factors. The diagnosis of aseptic loosening involves a careful history, focused clinical exam, and thorough evaluation of imaging using several diagnostic modalities. The careful evaluation of serial radiographs remains the cornerstone of diagnosis with additional input from advanced imaging modalities such as FDG-PET, DEXA, MRI, and several others, each offering unique advantages and disadvantages. In certain patients, history and physical exam might be the only initial obvious signs of loosening, and thus, unexplained continuous pain augmented by imaging findings serves as an indication for revision surgery. 相似文献
16.
《The Journal of arthroplasty》2020,35(8):2097-2100
BackgroundObese and morbidly obese patients undergoing primary total knee arthroplasty (TKA) place significant stress at the bone-cement-implant interface over the life of the patient. The purpose of this study is to evaluate results of cemented, posterior-stabilized TKA in obese and morbidly obese patients at an average follow-up of 10 years.MethodsRetrospective study of 181 patients who had a cemented, posterior-stabilized TKA between 2000 and 2013 with body mass index >35 at the time of surgery was conducted. Clinical data and radiographs were evaluated along with survivorship, complications, and revisions. Minimum follow-up was 5 years with an average follow-up of 10 years.ResultsThere were 135 women and 46 men in the study, with mean age of 60.2 years (range 43-80), mean body mass index of 42.0 (range 35.1-66.1), and an average follow-up of 10 years (range 5-18). There were a total of 39 failures (22%) that underwent revision TKA surgery with mean time to revision of 8 years. Failures included 25 (14%) cases of aseptic loosening; 9 (5%) polyethylene wear; 2 (1%) prosthetic joint infection; and 3 additional revisions for instability, pain, and stiffness. There were a total of 11 cases of isolated tibial component loosening and 13 for both tibial and femoral loosening. Survivorship at 15 years with aseptic loosening as the endpoint was 86.7%, and for all causes 79.6% at 15 years.ConclusionAseptic loosening is the leading cause of failure following TKA in obese and morbidly obese patients with decreasing survivorship from 96.1% to 91.2% and 86.7% at 5, 10, and 15 years, respectively. 相似文献
17.
The present study was undertaken to evaluate the clinical and radiological results of isolated femoral revisions conducted while retaining well-fixed cementless acetabular sockets. Thirty-nine patients that underwent isolated femoral stem revisions were reviewed. Mean age at time of surgery was 60.5 years, and mean follow-up duration was 4.2 years. Decisions to retain acetabular sockets were based on clinical and radiographic findings and intraoperative stabilities. During revisions, polyethylene liners were exchanged for metal-inlay polyethylene liners to have a metal-on-metal bearing surface in 23 cases. Mean Harris hip score improved from 58 points preoperatively to 85 points at final follow-up (P < .001). With the exception of one patient, no increases in acetabular radiolucent line numbers or thicknesses were observed during follow-up visits. Isolated femoral stem revisions with acetabular socket retention were found to provide excellent clinical and radiographic results. 相似文献
18.
Brian P. Chalmers Marie Syku Amethia D. Joseph David J. Mayman Steve B. Haas Jason L. Blevins 《The Journal of arthroplasty》2021,36(7):2348-2352
BackgroundThere are limited data on the outcomes of revision total knee arthroplasty in young patients. We sought to characterize the re-revision-free survival and risk factors for re-revision in patients less than 55 years who underwent aseptic revision TKA.MethodsWe retrospectively reviewed 197 revision TKAs at a mean follow-up of 5 years. Mean age was 49 years; mean body mass index was 31 kg/m2. Twenty-seven (14%) patients had at least 1 prior revision TKA. The most common indications for revision included instability (29%), arthrofibrosis (26%), and aseptic loosening (24%). Constraint included the following: 59 posterior-stabilized (30%), 123 varus-valgus constrained (62%), and 15 hinged (8%). Components revised included the following: 93 femur/tibia (47%), 68 polyethylene-only (35%), 19 femur-only (10%), and 17 other (9%). Survivorship free from re-revision was calculated via the Kaplan-Meier method and a multivariate Cox proportional regression was utilized to identify risk factors for re-revision.ResultsSurvivorship free from any re-revision at 5 years was 80%. In the multivariate analysis, patients with a prior revision (hazard ratio [HR] = 2.78, P = .02), an isolated polyethylene exchange (HR = 3.0, P = .004), and a hinged prosthesis (HR = 3.47, P = .05) were significant risk factors for lower revision-free survival. Forty-two patients (21%) underwent re-revision, most commonly for periprosthetic joint infection (7%), instability (6%), and aseptic loosening (5%). Re-revision occurred in 18/68 (26%) patients undergoing an isolated polyethylene exchange.ConclusionPatients less than 55 years undergoing revision TKA have a modest 5-year revision-free survival of 80%. Patients with prior revision TKAs (HR = 2.78), hinge type prostheses (HR = 3.47), and polyethylene-only revisions (HR = 3.0) had higher revision rates. 相似文献
19.
Brian P. Chalmers Peter K. Sculco Keith A. Fehring Robert T. Trousdale Michael J. Taunton 《The Journal of arthroplasty》2017,32(7):2274-2278
Background
There are limited data on evaluating the significance of radiolucent lines and aseptic loosening in total knee arthroplasty (TKA). We sought to compare the sensitivity, specificity, and reliability of the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System (KSRES) in detecting tibial component loosening compared to a novel percentage-based system (PBS).Methods
We retrospectively reviewed radiographs obtained from 48 patients within 6 months prior to revision TKA. The radiographs were randomized and four reviewers independently used the KSRES to categorize tibial implants as nonconcerning, clinical follow-up for progression, or loose as described by KSRES. For the PBS, the percent involvement of the tibial implant interface of any radiolucency at the bone-cement or cement-implant interface was determined. The higher percentage from either the anteroposterior or the lateral image was the final score. Components were categorized as nonconcerning (≤10%), clinical follow-up for progression (11%-24%), or loose (≥25%). We compared the sensitivity, specificity, and interobserver reliability using intraoperative assessment of implant fixation as the gold standard.Results
For the KSRES, the mean sensitivity for determining tibial loosening was 7.3% and mean specificity for determining a nonconcerning implant was 95.9%. The PBS significantly increased the sensitivity to 91.1% (P < .001) while maintaining a specificity of 87.9% (P = .2). Interobserver reliability significantly increased from a mean kappa of 0.26 to 0.75 (P < .001).Conclusion
The KSRES significantly underestimates implant loosening. The proposed percentage-based system demonstrated excellent sensitivity, specificity, and interobserver reliability in determining tibial implant loosening in this patient population. 相似文献20.
《The Journal of arthroplasty》2023,38(8):1493-1498
BackgroundRound or oval implants are used in patellar resurfacing during total knee arthroplasty (TKA). However, whether component geometry affects clinical outcomes is unclear. This study aimed to determine if one implant shape conferred superior outcomes to the other.MethodsA retrospective review of primary TKA cases performed from 2016 to 2020 was conducted at an urban, tertiary academic center. Four hundred consecutive, primary TKAs were included in these analyses. Cases were included if a surgeon used the round design then oval design for fifty consecutive cases. Baseline demographic data and radiographic measurements were assessed. Surgical data, reasons for revision, and patient-reported outcome measures were analyzed. Independent samples t-test and chi-square tests were used to compare means and proportions. There were no demographic differences between the cohorts.ResultsPostoperative patellar tilt was statistically different between the cohorts. Sixteen patients required revision surgery; however, revision rates did not differ between the cohorts. Of the 9 rounds, 1 button was revised for infection. Of the 7 ovals, 1 button was revised for infection and 1 for loosening. Veterans RAND 12 Physical Component Score at 3 months postoperatively was higher for the round cohort, but no differences were observed at 1 year.ConclusionWhile radiographic patellar tilt was significantly different between the cohorts, there was no clinical correlation in outcomes at 3 months or 1 year postoperatively. Longer-term follow-up studies are needed to evaluate the implications of patellar component design on outcomes and function. Nevertheless, the current study affirms that both designs are clinically equivalent which should be used to guide clinical decision-making.Level III evidenceRetrospective Cohort. 相似文献