首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.

Background

Both modular and nonmodular tapered fluted titanium stems are used in revision total hip arthroplasty (THA), with follow-up showing good results for both stems. We aimed to determine whether there were any differences in clinical outcomes, survivorship, or frequency of complications.

Methods

A retrospective review of 160 consecutive THAs (153 patients) revised with a tapered fluted modular titanium stem from 2002 to 2014 and 129 consecutive THAs (128 patients) revised with a tapered fluted nonmodular titanium stem between 2008 and 2014 was conducted. The patient's level of satisfaction, clinical assessment, and complications were examined. A Kaplan-Meier survivorship analysis was performed with the endpoint defined as any reoperation due to septic/aseptic complications.

Results

Mean duration of follow-up was longer in the modular group (6.3 years) than the nonmodular group (5.0 years; P = .003). No significant group differences were found in the postoperative Harris Hip Score, the level of overall satisfaction, the 8-year cumulative survival, the rate of infection, dislocation, or postoperative periprosthetic fractures. However, intraoperative fractures occurred significantly more frequently in the modular group (16.9%) than in the nonmodular group (7.0%; P = .011), and stem subsidence was significantly less in the modular group (0.95 mm) than in the nonmodular group (1.93 mm; P = .001). Two mechanical failures associated with the modular design occurred in the modular group.

Conclusion

Both modular and nonmodular tapered fluted titanium stems provide satisfactory midterm results in revision THA. Although tapered fluted modular stems are gaining in popularity in revision THA, tapered fluted nonmodular stems should not be disregarded as a viable alternative, especially for relatively straightforward cases.  相似文献   

2.
《The Journal of arthroplasty》2019,34(9):2011-2015
BackgroundGood bone quality and proper proximal femoral morphology are thought to be necessary for tapered design, cementless femoral stems to resist subsidence. Using tapered, cementless stem for patients with stovepipe morphology or Dorr type C is controversial. The purpose of this study is to analyze (1) subsidence of the fully hydroxyapatite (HA)-coated, tapered, cementless stem in different morphology according to Dorr classification, (2) subsidence of the stem related to radiographic canal-fill ratio.MethodsThe digitized radiographs of 311 consecutive cementless primary total hip arthroplasty with fully HA-coated, tapered stem were retrospectively reviewed. Subsidence and the canal-fill ratio at 4 locations were evaluated postoperatively after a minimum of 2 years of follow-up. The threshold of subsidence >3 mm was considered as a clinically significant migration.ResultsA multivariate regression analysis of subsidence across Dorr type, controlling for age, gender, and intraoperative calcar fracture, demonstrated 0.40 mm (P = .28) and 0.18 mm (P = .51) greater subsidence in Dorr type C and B when compared to Dorr type A. Age, gender, and calcar fracture had no influence on subsidence, whereas greater canal-fill ratio at 2 cm below lesser trochanter resulted in significantly less subsidence (P = .02). Additionally, all variables did not affect the risk of having subsidence >3 mm.ConclusionThe proximal femoral morphology has no statistically significant effect on the subsidence of fully HA-coated stem. Therefore, this stem type might be a viable option for Dorr type C. Increasing the canal-fill ratio at metadiaphyseal junction may ensure the stability of the stem.  相似文献   

3.
《The Journal of arthroplasty》2022,37(12):2420-2426
BackgroundTapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem.MethodsBetween December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years.ResultsThe mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision.ConclusionA tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.  相似文献   

4.
Cerclage wires have been used to stabilize proximal femoral cracks after stem insertion in cementless total hip arthroplasty. The objective of this study was to determine the optimal number and orientation of cerclage wires necessary to prevent stem subsidence and crack propagation. The crack was stabilized by 1, 2, or 3 wires placed either normal to the femoral neck axis or normal to the crack. The femora were compressed to 2,670 N while measuring crack opening and stem subsidence. Wires placed normal to the crack allowed less stem subsidence by 3.17 mm and less crack opening by 1.55 mm compared with wires placed normal to the neck. The addition of multiple wires reduced subsidence by 50% and reduced crack opening to < 1 mm. Medial and anterior calcar cracks are best stabilized by at least 2 cerclage wires that are placed normal to the crack.  相似文献   

5.
《The Journal of arthroplasty》2020,35(8):2195-2199
BackgroundWe describe the intraoperative parameters that affect stem subsidence rates in tapered modular femoral stems for revision total hip arthroplasty (THA). We also determine the effect of the stem bicortical contact on subsidence rates and whether there is a minimum threshold bicortical contact that must be achieved to avoid the complication of subsidence.MethodsThis is a retrospective cohort study consisting of 109 hips in 105 patients (53 males and 52 females) at a minimum of 2 years of follow-up. All revisions were carried out for Paprosky type 3A and 3B femoral deficits. Clinical outcomes included the indication for revision, aseptic re-revision surgery, specifications of the stem inserted, and specifications of the femoral head and acetabular components implanted. Radiographic outcome measures included subsidence (mm) and bicortical contact (mm).ResultsUsing multivariate regression analysis, 3 parameters were associated with an increased rate of stem subsidence. A reduced bicortical contact distance (P < .001) and a stem length of ≤155 mm (P < .001) were both associated with higher subsidence rates. We also demonstrated a novel threshold of 20-mm bicortical contact which must be achieved to significantly reduce subsidence rates in these modular femoral stems for revision THA.ConclusionSubsidence rates of modular tapered femoral stems for revision THA can be significantly reduced by increasing the initial bicortical contact of the stem within the diaphysis and the overall length of the femoral stem >155 mm. We describe a minimum threshold bicortical contact distance of 20 mm that should ideally be exceeded to significantly reduce the risk of stem subsidence within the femoral canal.  相似文献   

6.
《The Journal of arthroplasty》2020,35(8):2161-2166
BackgroundThis study reports the long-term outcomes of a metaphyseal fit-and-fill cementless femoral component in total hip arthroplasty (THA) with a follow-up of 15-19 years.MethodsWe conducted a retrospective review of 376 consecutive THAs (345 patients), using a triple tapered stem performed between 2000 and 2003 with a view to assessing survivorship and radiological and functional outcomes. Images were assessed for initial alignment, terminal osteolysis, or subsidence, while clinical outcomes were assessed using the St Michael’s Hip Score.ResultsForty-five (11.9%) hips were lost to follow-up, 20 (5.31%) had died before our 15-year cutoff follow-up, and 4 (1.06%) had declined follow-up early on, leaving 307 hips (81.64%, 276 patients) available for both clinical and radiological follow-up at a minimum of 15 years (range 15-19). The mean age at the time of operation was 49.6 years (range 19-71) and the cohort included 131 (42.67%) male and 145 (47.23%) female patients. Seven stems (2.28%) were revised: 4 due to periprosthetic fractures, 2 for periprosthetic joint infection, and 1 for adverse reaction to metal debris at the trunnion. The St Michael’s Hip Score improved from 14.2 (range 9-23) preoperatively to 22.3 (range 13 to 25) at the last documented follow-up (P = .000). Kaplan-Meier survivorship with stem revision for any reason as the end point was 97.70%. Worst-case scenario Kaplan-Meier survivorship, where all lost to follow-up are considered as failures, was 85.3%. No stem was revised for aseptic loosening.ConclusionThis triple tapered stem in THA shows excellent survivorship beyond a minimum of 15 years.  相似文献   

7.
《The Journal of arthroplasty》2020,35(12):3692-3696
BackgroundModular fluted tapered (MFT) stems are the most frequently used femoral component in revision total hip arthroplasties (THAs). Despite this, no data are available on how they perform in revision THA for oncologic salvage. This is a unique population, often with severe bone loss and prior radiation that extends the limits of uncemented femoral reconstruction. The aims of this study were to evaluate the implant survivorship, radiographic results, and clinical outcomes of MFT stems used for revision oncologic salvage.MethodsWe identified 17 patients treated initially with primary THA for an oncologic diagnosis (15 primary oncologic, 2 metastatic disease) who underwent subsequent femoral revision with an MFT stem. Mean age at revision was 66 years and 35% of patients were female. Mean follow-up was 4 years. Before revision, 5 of 17 had undergone local radiation.ResultsTen-year survivorship free from aseptic loosening was 100%. The survivorship free of any reoperation was 76%. There were no femoral component fractures. Three patients were revised for recurrent instability, and 1 patient underwent irrigation and debridement for an acute infection. At most recent follow-up, no patient had radiographic evidence of progressive femoral component subsidence or failure of osteointegration. The mean Harris Hip Score improved from 29 preoperatively to 76 postoperatively (P < .0001).ConclusionIn this series of patients with cancer, many of whom had severe bone loss and/or prior local radiation, being treated with revision THA, there were no revisions for femoral component loosening and no cases of implant fracture.Level of EvidenceIII.  相似文献   

8.

Background

There is a lack of understanding on relationship between the femoral geometry and outcomes of total hip arthroplasty (THA). We investigated clinical and radiographic outcomes of THA using a cementless tapered wedge stem in patients with Dorr type A proximal femoral morphology and compared with those of type B femurs at a minimum follow-up of 5 years.

Methods

We analyzed 1089 hips (876 patients) that underwent THA using an identical cementless tapered wedge stem. We divided all femurs into 3 types (Dorr type A, B, and C). Type A and B femurs were statistically matched with age, gender, body mass index, and diagnosis by using propensity score matching. Clinical, radiographic results, and stem survivorship were compared between the matched 2 groups.

Results

A total of 611 femurs (56%) were classified as type A, 427 (39%) as type B, and 51 (5%) as type C. More radiolucent lines around femoral stems were found in type A femurs (7.8%) than in type B femurs (2.5%) (P < .001). Patients with radiolucency showed worse Harris Hip Score (86.2 points) compared with those without radiolucency (93.0 points) (P < .001). The stem survivorship of type A femur (97.8%) was lower than that of type B femur (99.5%) (P = .041). The reasons for femoral revision in type A femurs were periprosthetic fracture (67%), aseptic loosening (22%), and deep infection (11%).

Conclusions

This study showed a higher rate of complications after THAs using a cementless tapered wedge stem in Dorr type A femurs than those performed in type B femurs.  相似文献   

9.

Background

Intraoperative fractures during total hip arthroplasty (THA) are more common when using cementless stems. The purpose of this study was to investigate the impact of a new shorter second-generation cementless, tapered wedge stem with improved proximal femoral fit in reducing the incidence of intraoperative fracture.

Methods

A retrospective study was conducted on primary THA cases performed at a single institution using a first-generation or second-generation cementless stem from 2006-2016. All intraoperative femur fractures were identified, as well as early 30-day postoperative periprosthetic femur fractures, which could represent nondisplaced intraoperative fractures that were initially missed. Risk for intraoperative femur fracture was analyzed using logistic regression, accounting for demographic covariates and surgeon.

Results

Of 6473 primary THA performed with a cementless, tapered wedge stem during the study period, 3126 used a first-generation stem and 3347 used a second-generation stem. The incidence of intraoperative fracture was 1.79% for first-generation stems and 0.24% for second-generation stems, representing a 7.5-fold reduction of risk for fracture. After accounting for covariates, the odds of intraoperative fracture were 0.33 using the second-generation stem relative to the first-generation stem (P = .01). However, there was no significant difference in the odds of early 30-day postoperative fractures using the second-generation stem (odds ratio 0.93, P = .56).

Conclusion

A new second-generation cementless stem resulted in a 7.5-fold decrease in the incidence of intraoperative femur fracture compared with the preceding stem.  相似文献   

10.
《Injury》2021,52(7):1801-1806
BackgroundBipolar hemiarthroplasty is a well-established treatment for displaced femoral neck fracture in elderly patients. Implant subsidence is a potential complication with cementless femoral stems, and smaller canal fill ratio has been reported as a radiographic risk factor. We aimed to determine the risk factors for subsidence, particularly the initial implant position relative to the resected medial calcar of proximal femur.MethodsWe retrospectively reviewed all cementless bipolar hemiarthroplasties performed using a single proximally hydroxyapatite-coated femoral stem in patients with a minimum radiographic follow-up of 12 weeks between January 2017 and December 2018. The amount of subsidence (significant subsidence defined as ≥ 5 mm), canal fill ratio, and implant position relative to the point of resected medial calcar (position A: medial and superior to calcar; position B: lateral and superior to calcar; position C: lateral and inferior to calcar) were measured and analyzed.ResultsOne-hundred eighty patients were identified (mean age: 80.9 years). Significant subsidence was observed in 52 patients (28.9%). On multivariate analysis, older age, lower canal fill ratio, implant position B, C, and less medial overhang of stem were independent risk factors for early implant subsidence. The risk ratio of position B and C to position A was 5.13 (95% confidence interval, 2.23-11.80).ConclusionIn our analysis, older age and lower canal fill ratio were associated with increased risk of subsidence, whereas implant with position A and more medial overhang were less prone to subsidence with the tapered proximally hydroxyapatite-coated implant.  相似文献   

11.
《The Journal of arthroplasty》2022,37(5):897-904.e1
BackgroundTotal hip arthroplasty (THA) for avascular necrosis (AVN) or inflammatory arthritis (IA) comes with a relatively high risk of aseptic stem loosening, especially in young patients. There are limited long-term data on the survivorship of polished, tapered, cemented stems in this population. We therefore performed a single-center retrospective study investigating the survival of this particular stem type in young patients with AVN or IA.MethodsAll patients aged ≤35 years who had received a THA for AVN or IA operated on by the senior author between 1990 and 2010 at the University Hospitals Leuven were identified. In total, 85 THAs in 62 patients were included. Primary endpoint was revision of the femoral component for aseptic loosening. Secondary endpoints were revision of the acetabular component for aseptic loosening, revision for other reasons, and the presence of radiolucencies around the components.ResultsThe mean follow-up for the entire cohort was 18.0 ± 5.3 years (range 8.0-28.9). Taking revision for aseptic loosening as endpoint, the survival of cemented stems was 100% after 15 years and 95.1% after 20 years. Survival of uncemented cups (91.3%) was significantly better than survival of cemented cups (50.3%) after 20 years of follow-up for aseptic loosening. Taking revision for any reason as endpoint, the survival of THAs with uncemented and cemented cups was 90% and 43.1% at 20 years respectively. Radiolucencies developed in the cement mantles around 11 of the 81 nonrevised stems, mainly in zones 1 and 7.ConclusionIn this cohort of young patients with high-risk profiles for aseptic stem loosening, polished, tapered, cemented stems showed excellent long-term survival rates and they therefore remain a viable alternative to uncemented stem designs.  相似文献   

12.

Background

An increased rate of complications related to femoral component failure has been described with less invasive total hip arthroplasty (THA). This study evaluated the incidence of femoral complications associated with the direct anterior approach for THA.

Methods

Retrospective review was performed of the initial 1120 consecutive patients who underwent direct anterior THA by 2 surgeons.

Results

A total of 899 patients (80.3%) had a 2-year follow-up (range, 2-8 years). Complications within 90 days occurred in 20 patients (1.8%): 10 calcar fractures, 1 greater trochanter fracture, 1 canal perforation, 3 hematomas, 2 dislocations, 2 superficial, and 1 deep infection. Nine patients (1%) underwent revision: 5 for aseptic femoral loosening (0.55%), 1 for periprosthetic joint infection, 1 for dislocation, 1 for hip flexor irritation, and 1 for a damaged polyethylene liner.Of the 5 patients with aseptic femoral loosening, 3 had a short, mediolateral tapered stem, 1 cemented stem, and 1 S-ROM stem placed to bypass a canal perforation. There were no revisions for aseptic loosening in the collared, fully hydroxyapatite (HA)-coated compaction broached or triple tapered proximal fit and fill stem designs (70.6% of all stems). Revision rate for femoral loosening was significantly higher for tapered wedge over HA-coated, compaction broached stems (P < .005).

Conclusion

Pain and function improved predictably with a 0.55% rate of femoral loosening at 2-year follow-up. Among collared, fully HA-coated and triple taper fit and fill femoral stems, there were no instances of revision for aseptic loosening vs 3 in the short stem, collarless mediolateral tapered group.  相似文献   

13.

Background

Femoral component stability and resistance to subsidence is critical for osseointegration and clinical success in cementless total hip arthroplasty. The purpose of this study was to radiographically evaluate the anatomic fit and subsidence of 2 different proximally tapered, porous-coated modern cementless femoral component designs.

Methods

A retrospective cohort study of 126 consecutive cementless total hip arthroplasties was performed. Traditional fit-and-fill stems were implanted in the first 61 hips with the remaining 65 receiving morphometric tapered wedge stems. Preoperative bone morphology was radiographically assessed by the canal flare index. Canal fill in the coronal plane, subsidence, and the sagittal alignment of stems was measured digitally on immediate and 1-month postoperative radiographs.

Results

Demographics and canal flare indices were similar between groups. The percentage of femoral canal fill was greater in the tapered wedge compared to the fit-and-fill stem (P = .001). There was significantly less subsidence in the tapered wedge design (0.3 mm) compared to the fit-and-fill design (1.1 mm) (P = .001). Subsidence significantly increased as body mass index (BMI) increased in the fit-and-fill stems, a finding not observed in the tapered wedge design (P = .013).

Conclusion

An anatomically designed morphometric tapered wedge femoral stem demonstrated greater axial stability and decreased subsidence with increasing BMI than a traditional fit-and-fill stem. The resistance to subsidence, irrespective of BMI, is likely due to the inherent axial stability of a tapered wedge design and may be the optimal stem design for obese patients.  相似文献   

14.
BackgroundBoth modular and monoblock tapered fluted titanium (TFT) stems have gained popularity over fully porous-coated cylindrical (FPCC) femoral stem designs, but limited data exist comparing subsidence rates following revision total hip arthroplasty (THA). The purpose of this study is to determine differences in subsidence and clinical outcomes among 3 revision femoral stem designs.MethodsWe reviewed a consecutive series of 335 patients who underwent femoral component revision to a cementless modular TFT (n = 225), monoblock TFT (n = 63), or FPCC (n = 47) stem between 2012 and 2019. We evaluated radiographic subsidence rates, re-revision rates, and patient-reported outcomes between the 3 stems. A multivariate regression analysis was performed to determine the independent effect of stem type on the risk of subsidence >5 mm.ResultsAt an average follow-up of 39 months (range, 12 to 96 months), there were no differences in mean subsidence rates (3.5 vs 2.4 vs 2.1 mm, P = .14), HOOS Jr scores (78 vs 74 vs 64 points, P = .15), or aseptic re-revision rates (4% vs 3% vs 0%, P = .29) between modular TFT, monoblock TFT, and FPCC stems. Although modular TFT stems were more often used in patients with extensive femoral bone loss (Paprosky III and IV), there were no differences in subsidence rates >5 mm among the 3 stems (P > .05) in multivariate analysis.ConclusionModular TFT, monoblock TFT, and FPCC femoral stem designs all perform well in revision THA with no difference in clinical outcomes or subsidence rates. Surgeons should select the stem which they feel is the most clinically appropriate.  相似文献   

15.
BackgroundThe purpose of this prospective matched paired study is to compare the in vivo migration patterns using Ein Bild Roentgen Analyze femoral component of shortened vs standard-length stems cemented line-to-line in primary total hip arthroplasty (THA) at 2-year follow-up.MethodsWe prospectively included the first 50 consecutive primary cemented THAs in 50 patients using a 12% shortened stem (AmisK group) of which design was derived from the original Charnley-Kerboull (CK) femoral components. These 50 patients were matched paired to 50 patients from a historical series of patients who underwent primary THAs using standard-length CK stems (CK group) with available long-term results, including Ein Bild Roentgen Analyze femoral component data at 2-year follow-up.ResultsBody mass index was significantly higher (P = .007) in the AmisK vs the CK group. At the 2-year follow-up, the mean subsidence was 0.65 mm (0-1.40) in the AmisK group vs 0.68 mm (0.07-1.43) in the CK group (P = .73). When using a 1.5-mm threshold, none of the stems in either group was considered to have subsided. Femoral cortical thickening in zones 3 and 5 occurred in 6 of the 50 hips (12%) in the AmisK group vs 20 (40%) of the 50 hips in the CK group (P = .003).ConclusionOur study showed that a shortened highly polished double-tapered stem cemented line-to-line provided similar results including minimal subsidence as its standard-length counterpart, with significantly less distal femoral cortical thickening. However, longer term survival analysis still needs to be determined.  相似文献   

16.
《The Journal of arthroplasty》2020,35(10):2911-2918
BackgroundTotal hip arthroplasty (THA) of patients with a proximal femoral deformity is technically demanding. This deformity poses the risk of femoral fracture or perforation; stem malposition; and failed stem fixation. To insert a femoral stem in neutral position with a good fit, we removed the greater trochanter in case of a varus deformity, and the lesser trochanter in case of valgus deformity, while performing THA. We aimed to evaluate stem position, implant stability, clinical results, and radiological changes after THAs using this technique.MethodsFifteen patients (17 hips; 11 varus hips and 6 valgus hips) underwent cementless THA using the trochanteric osteotomy technique in one institution. We evaluated procedure-specific complications: intraoperative femoral fracture, stem malposition, weakness of the abductor power and limp. Modified Harris Hip Score, radiological changes, and the stability of stems were assessed at a mean of 7.1 years of follow-up (range 2.0-15.5).ResultsFemoral fracture occurred during the insertion of the stem in 4 hips. All stems were aligned in neutral position. At the latest follow-up, the mean power of the abductor was 4.3 (range 3-5). Eleven patients had slight limp and 4 patients had moderate limp. All stems had bone-ingrown stability and no stem was revised. The mean modified Harris Hip Score improved from 50 points at the preoperative evaluation to 81 points at the final follow-up.ConclusionThe trochanteric excision enabled neutral insertion of cementless stem in patients with varus/valgus deformity of the proximal femur, and THA using this technique rendered favorable results.  相似文献   

17.
BackgroundRecent studies indicate a decreased risk of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) for short compared to straight stems. However, the results are still inconclusive. Therefore, we retrospectively investigated the rate of PFFs within the first year between cementless short and straight stem THA.MethodsA 1:1 propensity score matching of 3,053 THAs was performed. Two groups including 1,147 short stem THAs implanted through a minimally invasive antero-lateral approach and 1,147 straight stem THAs implanted through a transgluteal Hardinge approach were matched. The rates of PFFs and fracture patterns were compared between both stem types. Risk factors for PFFs were analyzed by multivariate regression analyses.ResultsThe overall rate of PFFs was 1.7% in short stem THA and 3.2% in straight stem THA (P = .015). Postoperatively detected Vancouver A fractures occurred significantly more often in straight stem THA (P = .002), while the occurrence Vancouver B fractures did not differ significantly (P = .563). The risk of PFFs was significantly increased for women in straight stem THA (Odds ratio (OR) 2.620; Confidence Interval (CI) 1.172-5.856; P = .019). Increasing age showed a significantly increased odds ratio in short stem (OR 1.103; CI 1.041-1.169, P < .001) and straight stem THA (OR 1.057; CI 1.014-1.101, P = .008).ConclusionShort stem THA reduces Vancouver Type A PFFs in the trochanteric region compared to straight stem THA, while Vancouver Type B fractures are comparable. Increasing age is a significant risk factor for both stem types, while the risk for PFFs in women was only significantly increased in the straight stem group.  相似文献   

18.
《The Journal of arthroplasty》2019,34(6):1127-1131
BackgroundProper component positioning in total hip arthroplasty (THA) is crucial for implant fixation and hip stability. The purpose of this study is to assess if neutral coronal stem alignment (0° ± 3°) improved long-term survivorship in uncemented femoral components.MethodsBetween 2005 and 2010, 1028 primary THAs were performed with 2 contemporary dual-tapered, proximally coated uncemented stem types. Alignment was measured immediately postoperatively and at most recent follow-up. In total, 978 femoral stems (95%) were within 0° ± 3° of the neutral anatomic coronal axis, and the 50 stems (5%) outside that range were considered outliers (3.1° of valgus to 4.8° of varus). Outcomes analyzed included implant survivorship, Harris Hip Scores, and incidence of dislocation. Mean follow-up was 5 years.ResultsSurvivorship free of aseptic femoral component loosening was 99.3% and 98.2% at 5 and 8 years in the neutral group vs 100% at 5 and 8 years in the outlier group (P = .98). Survivorship free of femoral component revision for any reason was 99.1% and 97.3% at 5 and 8 years vs 100% at 5 and 8 years, respectively (P = .80). Harris Hip Scores were similar (89 in both groups; P = .84) at most recent follow-up. The incidence of mild to moderate thigh pain was also similar in both groups (6.1% vs 6%, P = .85). The incidence of dislocation was 1.5% at 8 years, and similar between both groups (P = .77).ConclusionSlight malalignment of contemporary dual-tapered uncemented THA femoral components does not appear to negatively impact survivorship or clinical outcomes, which is in contrast to cemented femoral components.Level of evidence IIICase-control study.  相似文献   

19.
《The Journal of arthroplasty》2023,38(7):1287-1294.e2
BackgroundThis study aimed to determine if “short” femoral stems were noninferior to (at least as good as) standard-length stems in regards to 90-day periprosthetic fracture and 1-year revision rates.MethodsUsing the MARCQI implant registry, a retrospective study of statewide data was carried out on 64,084 total hip arthroplasties (THAs) between 2012 and 2017. We noticed an increase in the use of “short” uncemented femoral hip stems during THA. Chi-square tests were used to test homogeneity of categorical variables. The covariates included in the analyses were identified using modern epidemiological methods. A Type I probability of 0.05 was used as the level of statistical significance. Inverse probability of treatment weighting (IPTW) was used to mitigate confounding variables.ResultsOne hundred and seven stems were implanted by surgeons in the state of Michigan. They were classified according to the Khanuja Classification System as Type 2A (trapezoidal, double-tapered calcar loading, n = 3,281), Type 3 (calcar loading with lateral flare, n = 1,898), and Type 4 (shortened, tapered, conventional, n = 19,580), and were compared to standard-length, type 5, stems (n = 33,322) in regards to the 2 outcomes (periprosthetic fractures and 1-year revision rates). Overall, 1-year revision and the 90-day fracture rates were 1.3% (791/57,853) and 1.1% (631/57,968), respectively. Noninferiority was established for all short stems at the clinical threshold of an odds ratio (OR) of 1.5 with P-values <0.05 for 90-day fractures. In regards to 1-year revision rates, noninferiority was also established for Type 3 and 4 stems (P < .05).ConclusionThe increased use of "short stems" in Michigan did not lead to increased 1-year revision or 90-day fracture rates.  相似文献   

20.
《The Journal of arthroplasty》2020,35(7):1885-1890
BackgroundThe aim of this study is to evaluate midterm clinical and radiographic results of total hip arthroplasties (THAs) with cementless implants for adult patients with sequelae from childhood hip infection.MethodsBetween 2002 and 2016, 165 patients (165 hips) who had a hip infection during childhood were treated with THAs with cementless implants. The average duration of follow-up was 93.5 months (range 26-206). Clinical results were evaluated via the Harris Hip Score and radiographic results were analyzed with postoperative serial X-rays.ResultsThe average Harris Hip Score increased from 27 (range 8-53) before surgery to 91 (range 45-100) at the latest follow-up examination (P < .001). At the latest follow-up evaluation, 9 cementless acetabular components demonstrated partial, nonprogressive radiolucencies. No subsidence of more than 2 mm or evidence of a radiolucent line was observed around the femoral components. Intraoperative periprosthetic fractures occurred in 11 hips, including 3 acetabular fractures, 2 fractures of greater trochanter, 1 femoral shaft fracture, and 5 fractures of femoral calcar. Postoperative complications included 3 cases of periprosthetic infection, 1 episode of dislocation, 1 case of a femoral periprosthetic fracture, 5 cases of sciatic nerve injury, 1 case of femoral nerve injury, and 1 case of squeaking from a ceramic bearing surface.ConclusionCementless THA for adult patients with sequelae from childhood hip infection presents significant technical challenges and a relatively high complication rate. With meticulous surgical planning and anticipation for the key technical challenges frequently encountered, the medium-term clinical and radiographic results of THA in this setting were good with high implant survivorship and patient satisfaction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号