首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《The Journal of arthroplasty》2022,37(12):2420-2426
BackgroundTapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem.MethodsBetween December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years.ResultsThe mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision.ConclusionA tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.  相似文献   

2.
《The Journal of arthroplasty》2022,37(12):2374-2380
BackgroundThis study aimed to determine the differences in survivorship, clinical function, and complications among patients who have Hartofilakidis Type C1 or C2 developmental dysplasia of the hips and underwent total hip arthroplasty (THA) with cementless implants.MethodsThis retrospective study identified 84 Hartofilakidis Type C hips that underwent THA between 2002 and 2011 with a minimum 10-year follow-up (mean, 13 years, range, 10 to 19 years). Survivorship, latest Harris Hip Scores and satisfaction levels, radiographic outcomes (eg, implant stability, rate and length of subtrochanteric shortening transverse osteotomy, leg-length discrepancy, cup position, and orientation), as well as complications (eg, dislocation, periprosthetic fracture, periprosthetic joint infection) were compared to analyze the differences between Hartofilakidis C1 and C2 hips.ResultsBetween C1 and C2 hips, no difference existed in the 15-year cumulative Kaplan-Meier survivorship, with the endpoint defined as any reoperation (93.1 versus 90.8%), aseptic loosening combined with periprosthetic joint infection (93.1 versus 96.2%), or aseptic loosening (94.8 versus 96.2%), latest Harris Hip Score (87.1 versus 86.1%), vertical (6.1 versus 6.0 mm) and horizontal (11.5 versus 10.3 mm) distance to the anatomic center of rotation, postoperative leg length discrepancy (11.2 versus 15.5 mm), dislocation (5.2 versus 11.5%), stem aseptic loosening (6.9 versus 7.7%), periprosthetic fracture (3.4 versus 7.7%), and intraoperative femoral fracture (32.8 versus 23.1%). However, Type C2 hips demonstrated more severe preoperative leg length discrepancy (66.9 versus 42.5 mm) and required a higher percentage of subtrochanteric shortening transverse osteotomies (84.6 versus 36.2%) that were longer (33.7 versus 26.47 mm) than the Type C1 hips.ConclusionWith cementless cups positioned near the anatomic acetabular center and cementless stems combined with subtrochanteric shortening transverse osteotomies, THAs for the Hartofilakidis Type C1 and C2 hips demonstrated similar survivorship, clinical function, and complications.  相似文献   

3.
BackgroundThe aim of the present study is to assess the long-term clinical and radiological outcomes of a proximal porous-coated, dual-offset, tapered titanium alloy uncemented stem at a minimum of 15 years of follow-up.MethodsWe reviewed 210 total hip arthroplasties (in 193 patients) performed between 1996 and 1999 and followed prospectively in our database who received the Synergy stem. We report a Kaplan-Meier survival analysis as well as the Harris Hip Score, the Western Ontario and McMaster University Arthritis Index, and the Short Form Health Survey-12 scores. Radiographs were evaluated for evidence of subsidence, osteolysis, osteointegration, or loosening.ResultsThe average follow-up was 16 years (range, 15-17.7 years). Kaplan-Meier survival analysis with revision of stem for aseptic mechanical loosening (1 stem) as the end point revealed a cumulative survival rate of 99.5% at 16 years. The Harris Hip Score, the Western Ontario and McMaster University Arthritis Index, and the Short Form Health Survey-12 physical scores were all significantly improved (P < .001) from the preoperative period to latest follow-up. Minor osteolysis was observed proximally in 14 hips (6.6%) with no osteolysis distal to the porous coating.ConclusionTo our knowledge, this study represents the largest series reporting the longest clinical follow-up of this third-generation, dual-offset, proximal ingrowth, tapered cementless stem. The Synergy stem design has achieved excellent clinical outcomes, predictable osteointegration, and outstanding survivorship of 99.5% at a minimum of 15 years follow-up, representing the standard for femoral stems at our institution.  相似文献   

4.
《The Journal of arthroplasty》2020,35(8):2131-2135
BackgroundOsteogenesis imperfecta (OI) comprises a spectrum of disorders that result in bone fragility. This presents unique challenges when performing total joint arthroplasty in patients with OI. The purpose of this study is to determine the survivorship and clinical outcomes of total hip arthroplasty (THA) in patients with OI.MethodsWe retrospectively reviewed our institution’s total joint registry from 1969 to 2018 for all primary THAs in patients with a history of OI. There were 11 patients (13 hips) with a mean follow-up of 13 years (range 6-20). Survivorship free of component revision was determined using Kaplan-Meier analysis. Patient-reported clinical outcomes were assessed using Harris Hip Scores.ResultsAt final follow-up, the status of the implant was known in all 13 hips. One patient (1 hip) was deceased. Four hips (31%) underwent revision surgery at a mean of 9 years (range 5-17). Survivorship free of component revision was 52% at 20 years. Mean Harris Hip Scores at final follow-up were fair (75, 47-97), but significantly improved compared to available preoperative scores (P = .0015). No intraoperative complications occurred during the 13 primary THAs.ConclusionTHA in patients with OI is associated with high revision rates and low survivorship at long-term follow-up. Although this is a very challenging patient population, THA provided these patients with improved functional outcomes. To the authors’ knowledge, this is the largest series of primary THA in patients with OI reported in the literature and therefore provides surgeons with important data regarding the expected outcomes following THA in this unique patient population.Level of EvidenceLevel IV.  相似文献   

5.
BackgroundThe purpose of this study was to document complications, outcomes, and 10-year survivorship of primary total hip arthroplasty (THA) using a direct anterior approach with an uncemented, straight, hydroxyapatite-coated stem and an uncemented cup.MethodsA retrospective, consecutive series of 275 primary THAs through a direct anterior approach with traction table using Medacta Versafit cup and Quadra-H stem with a minimum of 10-year follow-up was identified. The cumulative 10-year survival of the implants was estimated using Kaplan-Meier estimator. All complications, reoperations, and failures were analyzed. Subjective and clinical outcomes (Subjective Hip Value, Western Ontario and McMaster Universities Osteoarthritis Index, and Harris Hip Score) were measured.ResultsOf 256 patients (275 hips, 143 men and 113 women) with a mean age of 63 (range, 24-85) years, 48 (19%) patients (52 hips) deceased not related to the surgery after a mean time 49 months (range, 3-118) postoperatively. At >10-year follow-up, 9 THAs were revised. The overall implant survival rate was 96.8% (95% confidence interval, 94.4-98.7) at 10 years. One cup and 1 stem were revised because of aseptic loosening. At the last follow-up, the median Subjective Hip Value was 90% (range, 20-100), the Western Ontario and McMaster Universities Osteoarthritis Index score reached a median of 0.2 points (range, 0-6.3), and the median Harris Hip Score points was 99 (range, 29-100).ConclusionPrimary THA through an anterior minimal invasive approach with the mentioned implants showed low revision rates and good to excellent clinical outcome after at least 10 years.  相似文献   

6.
《The Journal of arthroplasty》2021,36(10):3485-3489
BackgroundWith improved materials and bearing surfaces, the use of total hip arthroplasty (THA) in young patients is increasing. Functional outcomes and activity level are particularly relevant in this higher-demand patient population. There is a paucity of data on patient-reported outcomes and activity levels after THA in extremely young (<21 years old) patients.MethodsWe identified 196 patients (222 hips) who underwent THA at age <21 years at our institution from 1982 to 2018. After applying exclusion criteria, 113 of 160 (70.6%) patients (129 hips) were available for follow-up. Patient activity levels and functional outcomes were evaluated using the UCLA activity score, Forgotten Joint Score (FJS), Hip Disability and Osteoarthritis Outcome Score for Joint Replacement, and a validated 5-question satisfaction survey. Survivorship and reasons for revision were recorded.ResultsThe mean age at surgery was 17.0 ± 2.8 years, and the mean follow-up was 13.2 years (range 2-38 years). The most common indications for THA were osteonecrosis (34%) and juvenile idiopathic arthritis (30%). The mean UCLA activity score was 5.9 ± 2.0, and 64% of patients reported a score ≥6. The mean FJS was 57.9 ± 31.0. The mean Hip Disability and Osteoarthritis Outcome Score for Joint Replacement score was 84.6 ± 16.6. Ninety percent of patients reported that they were very or somewhat satisfied with their surgery. At final follow-up, 27 of 129 (20.9%) hips had undergone revision surgery.ConclusionTHA performed in patients under 21 years of age with end-stage hip disease allows for high levels of activity and satisfaction postoperatively, with most patients being able to participate in moderate recreational activities. These data may be useful for surgeons in planning for and counseling extremely young patients indicated for THA.  相似文献   

7.

Background

The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship.

Methods

Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points.

Results

The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point.

Conclusion

The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired.  相似文献   

8.
BackgroundThere are no reported results for more than 20 years of a pure proximal-loading anatomic cementless femoral stem without diaphyseal stem fixation. The purpose of this study was to evaluate the long-term (minimum 20 years) clinical results, bone remodeling, revision rate, and survivorship of these implants in patients aged less than 60 years.MethodsWe included 523 patients (657 hips), including 319 men and 204 women. The mean body mass index was 26.7 (range, 23-29 kg/m2). The mean age of patients at index surgery was 55 years (range, 20-59 years). The Harris Hip Score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the University of California, Los Angeles activity score were recorded preoperatively and at each follow-up. Mean follow-up was 23.5 years (range, 20-27 years).ResultsThe Harris Hip Score at the final follow-up was a mean 93 points (range, 70-100 points). The Western Ontario and McMaster Universities Osteoarthritis Index and University of California, Los Angeles activity scores at the final follow-up were 16 and 7.6 points, respectively. Five femoral components (0.8%) and 13 acetabular components (2.0%) were revised. All cases in the current series had grade 2 stress shielding; no hips had grade 3 or 4 stress shielding. Kaplan-Meier survivorship of the implants at 23.5 years was 98.0% (95% confidence interval 92%-100%) for the acetabular component and 99.2% (95% confidence interval 93%-100%) for the femoral component.ConclusionA pure proximal-loading metaphyseal-fitting anatomic cementless stem with alumina-on-alumina ceramic bearing couples functioned well, with no osteolysis or mild stress-shielding at an average 23.5-year follow-up.  相似文献   

9.
《The Journal of arthroplasty》2020,35(6):1642-1650
BackgroundThe direct anterior approach (DAA) is increasingly used for total hip arthroplasty (THA). Although the DAA can reduce pain, recovery time, and dislocations in nondysplastic hips, few studies report its results in patients with severe dysplasia. We aimed to evaluate outcomes of primary THA through the DAA with cup placement at the true acetabulum in hips with severe dysplasia.MethodsWe retrospectively evaluated 23 consecutive patients (29 hips) who underwent THA by DAA for osteoarthritis secondary to Crowe III-IV dysplasia. Surgical procedures were performed on a traction table, and the acetabular cup was placed in the true acetabulum. Patients were assessed clinically (complications, modified Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index, Oxford Hip Score) and radiographically (radiolucencies, subsidence, leg length discrepancies, cup inclination, and cup coverage) at a minimum of 2 years.ResultsOne patient (2 hips) died with original implants (at 13 and 14 years), 3 patients (3 hips) were revised due to wear-induced loosening (at 14, 16, and 18 years), and there were no dislocations or infections. The remaining 19 patients (24 hips) were assessed at 8.4 ± 4.7 years (range 2-20); 2 patients (2 hips) had complications that required reoperation without implant removal. The modified Harris Hip Score improved from 32 ± 9 to 94 ± 7, Western Ontario and McMaster Universities Osteoarthritis Index from 46 ± 18 to 90 ± 7, and Oxford Hip Score was 56 ± 4. Patients were very satisfied (90%) or satisfied (10%). Limb length discrepancy was 2.5 ± 9.0 mm.ConclusionTHA through the DAA with cup placement at the true acetabulum provides satisfactory mid to long-term clinical and radiographic outcomes compared to other approaches for hips with severe dysplasia.Level of EvidenceLevel IV, retrospective cohort study.  相似文献   

10.
BackgroundTo report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL).MethodsFrom a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors.ResultsThe 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030).ConclusionOf 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.  相似文献   

11.
《The Journal of arthroplasty》2022,37(9):1816-1821
BackgroundConventional polyethylene (CPE) was used widely in the past as a bearing surface in total hip arthroplasty (THA). As CPE THAs age and the revision burden continues to grow, it is increasingly important to understand the durability and failure mechanisms of this bearing material. Currently, such long-term data remain limited, particularly in younger, more active patients in whom wear issues are of greater concern.MethodsWe retrospectively reviewed 90 hips (77 patients) that underwent primary THA with CPE bearings on cobalt chrome femoral heads at age ≤50 years at 20-year minimum follow-up (mean 21.6 [20-23]). We analyzed polyethylene wear rates, clinical outcomes (modified Harris Hip Score, University of California, Los Angeles Activity Score), and implant survivorship.ResultsWear analysis revealed a median linear wear rate of 0.113 mm/y (95% CI 0.102-0.148) and a median volumetric wear rate of 41.20 mm3/y (95% CI 43.5-61.0). Modified Harris Hip Scores remained 37 points above preoperative baseline (P < .001) and University of California, Los Angeles scores 1.4 points above baseline (P = .018) at 21.6-year mean follow-up. Twenty-nine hips (32.2%) were revised, 20 of which (22.2%) were wear-related at a median of 15.4 years (interquartile range 11.4-19.5). Survivorship free from wear-related revision was 95.6% (95% CI 88.7-98.3), 87.9% (78.6-93.3), 78.1% (49.6-66.5), and 61.1% (41.3-67.0) at 10, 15, 20, and 25 years.ConclusionWear-related issues developed at increasingly high rates after 15 years, suggesting the need for surveillance after this time. The long-term wear and survivorship data of this study may be used as a benchmark when evaluating the performance of contemporary bearings in young, active THA patients.  相似文献   

12.
《The Journal of arthroplasty》2020,35(10):2911-2918
BackgroundTotal hip arthroplasty (THA) of patients with a proximal femoral deformity is technically demanding. This deformity poses the risk of femoral fracture or perforation; stem malposition; and failed stem fixation. To insert a femoral stem in neutral position with a good fit, we removed the greater trochanter in case of a varus deformity, and the lesser trochanter in case of valgus deformity, while performing THA. We aimed to evaluate stem position, implant stability, clinical results, and radiological changes after THAs using this technique.MethodsFifteen patients (17 hips; 11 varus hips and 6 valgus hips) underwent cementless THA using the trochanteric osteotomy technique in one institution. We evaluated procedure-specific complications: intraoperative femoral fracture, stem malposition, weakness of the abductor power and limp. Modified Harris Hip Score, radiological changes, and the stability of stems were assessed at a mean of 7.1 years of follow-up (range 2.0-15.5).ResultsFemoral fracture occurred during the insertion of the stem in 4 hips. All stems were aligned in neutral position. At the latest follow-up, the mean power of the abductor was 4.3 (range 3-5). Eleven patients had slight limp and 4 patients had moderate limp. All stems had bone-ingrown stability and no stem was revised. The mean modified Harris Hip Score improved from 50 points at the preoperative evaluation to 81 points at the final follow-up.ConclusionThe trochanteric excision enabled neutral insertion of cementless stem in patients with varus/valgus deformity of the proximal femur, and THA using this technique rendered favorable results.  相似文献   

13.
BackgroundThe purpose of the present study was to update and report clinical outcomes and survival of primary total hip arthroplasty using a cementless double-tapered titanium fully hydroxyapatite-coated stem at a follow-up > 30 years.MethodsThe outcomes of this series of 347 primary total hip arthroplasties were already published at a follow-up > 25 years, during which only 12 stems were revised. Since then, there were two additional stem revisions, bringing the total to 14 stem revisions (all of which also required cup revision). Patients still living with the original stem were assessed using the modified Harris Hip Score and patient satisfaction (very satisfied, satisfied, dissatisfied, and very dissatisfied). Revision incidence was calculated using the Kaplan-Meier (KM) method and Cumulative Incidence Function (CIF) at 35 years.ResultsAt a mean follow-up of 33 years (range, 31 to 35 years), 32 patients (34 hips) were still living with the original stem. Their mean modified Harris Hip Score was 86 points (range, 46 to 100) and all patients (100%) were very satisfied or satisfied with surgery. The revision incidence at 35 years considering (a) stem revision for any reason was 9.5% using KM and 4.5% using CIF; (b) stem revision for aseptic loosening was 3.1% using KM and 2.1% using CIF; and (c) reoperation or revision of any component for any reason was 45.3% using KM and 26.3% using CIF.ConclusionThe present study has demonstrated excellent survival at 35 years for a cementless double-tapered titanium fully hydroxyapatite-coated stem.Level of EvidenceLevel IV, Retrospective cohort study.  相似文献   

14.
《The Journal of arthroplasty》2020,35(8):2155-2160
BackgroundTotal hip arthroplasty (THA) in patients with abnormal proximal femoral anatomy requires an individualized treatment approach to prevent complications. Metaphyseal engaging stems in this population risk fracture, size/offset mismatch, and aseptic loosening. The Wagner conical femoral implant is a short diaphyseal engaging femoral stem that could improve treatment success in this difficult patient population.MethodsWe identified 302 consecutive patients undergoing THA using the Wagner cone femoral prosthesis between January 2010 and January 2017. Clinical, radiographic, and patient-reported outcomes were obtained through chart review and radiographic measurements of postoperative X-rays. We used multivariate analysis to determine predictors of poor outcomes. Kaplan-Meier curves were created to demonstrate implant survivorship with reoperation and revision as endpoints. The average follow-up was 3.2 years, with a minimum of 2 years.ResultsThe implant retention survival rate during the 3.2-year study period was 98.7%. The overall reoperation rate was 4.2%, with infection followed by fracture being the most common reasons for reoperation. No patients were revised for aseptic loosening, and no patients were revised for subsidence. The average subsidence was 1.1 mm. The Harris Hip Score improved from 48.6 ± 7.3 (range, 28-64) preoperatively to 86.1 ± 8.5 (range, 66-100) at latest follow-up. The patient-reported satisfaction rate was 98.3%.ConclusionThe Wagner cone femoral prosthesis demonstrated excellent clinical, radiographic, and patient-reported functional outcomes at midterm follow-up. We recommend use of the Wagner cone in THA patients with challenging proximal femoral anatomy, small femoral diameter, or poor metaphyseal bone quality.  相似文献   

15.
《The Journal of arthroplasty》2021,36(10):3519-3526
BackgroundTotal hip arthroplasty (THA) performed for developmental dysplasia of the hip is a technically difficult procedure with a high complication rate, especially in the presence of completely dislocated hips. This study aimed to evaluate at least 10 years of follow-up results of cementless, ceramic-on-ceramic (CoC) THA performed with transverse subtrochanteric osteotomy in Crowe type IV hips.MethodsWe retrospectively reviewed 50 patients’ 67 hips that underwent CoC, cementless THA with transverse subtrochanteric osteotomy between 2008 and 2011. Clinical and radiological data of the hips were examined. Clinical results were evaluated using the Harris Hip Score and the Western Ontario and McMaster Universities Osteoarthritis Index.ResultsThe mean Harris Hip Score improved from 22.9 ± 9.9 preoperatively to 94.1 ± 8.1 at the final follow-up (P < 0.001). The median Western Ontario and McMaster Universities Osteoarthritis Index score improved from 72 (interquartile range: 17) preoperatively to 2 (interquartile range: 17) postoperatively (P < 0.001). The preoperative mean leg length discrepancy was improved from 4.9 ± 1 cm to 1.5 ± 1 cm in unilateral cases at the last follow-up (P < 0.001). Revision surgery was required because of nonunion in two patients, prosthetic infection in one patient, and aseptic femoral loosening in the other patient. The overall ten-year survival rate was 94% for femoral stems and 98.5% for acetabular components as per Kaplan-Meier survival analysis.ConclusionTransverse subtrochanteric shortening osteotomy combined with using cementless acetabular and femoral components with a CoC bearing surface promises successful clinical results and high prosthesis survival in the treatment of Crowe IV hips at long-term follow-up.  相似文献   

16.
BackgroundFor the past 2 decades, the authors have been using a long tapered cementless stem made of titanium and fully coated with hydroxyapatite for revision total hip arthroplasty. The purpose of this multicentric study is to assess clinical outcomes, radiographic outcomes, re-revision rates, and survival rates of this revision stem at a minimum 5-year follow-up.MethodsThe records of a multicentric continuous series of 335 adults undergoing revision total hip arthroplasty using the Corail revision stem (DePuy, Leeds, UK) between 2000 and 2012 were retrospectively reviewed. The Harris Hip Score, Oxford Hip Score, and Engh score were recorded. Survival was assessed using the Kaplan-Meier method and cumulative incidence function.ResultsSeventy-seven patients died with their revision stem in place, 47 could not be contacted, and 22 had stem re-revisions. This left a final cohort of 201 patients, aged 70 ± 12 years at revision surgery, with a body mass index of 26 ± 4. The Kaplan-Meier survival was 93.9% for re-revision of any component for any reason, 96.7% for re-revision of the stem for any reason, and 99.3% for re-revision of the stem for aseptic reasons. At last follow-up, the Harris Hip Score was 84.8 ± 13.1, the Oxford Hip Score was 21.0 ± 7.8, and the Engh score was 16.4 ± 6.7.ConclusionThe long tapered cementless revision stem had excellent clinical and radiographic outcomes at a minimum follow-up of 5 years. The revision stem enabled restoration of bone stock in femurs with pre-revision bone defects, confirming that the hydroxyapatite coating promotes osseointegration, even in femurs with extensive bone loss.Level of EvidenceLevel IV, retrospective cohort study.  相似文献   

17.
《The Journal of arthroplasty》2023,38(8):1539-1544
BackgroundThere are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA.MethodsAmong the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up.ResultsSurvivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification.ConclusionThis CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.  相似文献   

18.
BackgroundTotal hip arthroplasty (THA) is the most effective treatment option for patients with symptomatic osteoarthritis after a prior femoroacetabular osteoplasty (FAO). This study evaluated clinical outcomes of THA after a prior FAO and compared the results with a matched group of patients who underwent THA with no prior surgical procedures in the affected hip.MethodsBy reviewing our prospectively maintained database, we identified 74 hips (69 patients) that underwent THA after previous FAO between 2004 and 2017. They were matched 1:3 to a control group of primary THA with no history of any procedures on the same hip based on age, sex, body mass index, date of surgery, Charlson comorbidity index, surgical approach, and acetabular and femoral component type. At minimum 2-year follow-up, modified Harris Hip Score, 90-day readmission, and revision THA for any reason were compared between the groups.ResultsThe median time interval between FAO and subsequent THA was 1.64 years. There was no significant difference in preoperative Harris Hip Score between patients in the case and control cohorts. At the latest follow-up, the median modified Harris Hip Score was 77.6 in the case group and 96.2 in the control, and the difference was not statistically significant. None of the patients in the case group developed infection. 7 patients in the case group required additional procedures at any point, compared with 15 in the control.ConclusionTHA after prior FAO has similar outcomes to primary THA in patients with no prior procedures in the affected hip. THA can be performed safely with excellent outcome in patients with a history of FAO.  相似文献   

19.
《The Journal of arthroplasty》2020,35(12):3692-3696
BackgroundModular fluted tapered (MFT) stems are the most frequently used femoral component in revision total hip arthroplasties (THAs). Despite this, no data are available on how they perform in revision THA for oncologic salvage. This is a unique population, often with severe bone loss and prior radiation that extends the limits of uncemented femoral reconstruction. The aims of this study were to evaluate the implant survivorship, radiographic results, and clinical outcomes of MFT stems used for revision oncologic salvage.MethodsWe identified 17 patients treated initially with primary THA for an oncologic diagnosis (15 primary oncologic, 2 metastatic disease) who underwent subsequent femoral revision with an MFT stem. Mean age at revision was 66 years and 35% of patients were female. Mean follow-up was 4 years. Before revision, 5 of 17 had undergone local radiation.ResultsTen-year survivorship free from aseptic loosening was 100%. The survivorship free of any reoperation was 76%. There were no femoral component fractures. Three patients were revised for recurrent instability, and 1 patient underwent irrigation and debridement for an acute infection. At most recent follow-up, no patient had radiographic evidence of progressive femoral component subsidence or failure of osteointegration. The mean Harris Hip Score improved from 29 preoperatively to 76 postoperatively (P < .0001).ConclusionIn this series of patients with cancer, many of whom had severe bone loss and/or prior local radiation, being treated with revision THA, there were no revisions for femoral component loosening and no cases of implant fracture.Level of EvidenceIII.  相似文献   

20.
《The Journal of arthroplasty》2022,37(9):1799-1808
BackgroundMetal-on-metal hip resurfacing is an alternative to total hip arthroplasty (THA). The aim of this study was to determine implant survivorship, analyze patient-reported outcomes measures and to determine patient satisfaction for patients who underwent metal-on-metal hip resurfacing at a large US academic institution by a single surgeon with a minimum of 10-year follow-up.MethodsPatients who underwent hip resurfacing from September 2006 through November 2009 were included. Patient demographics and variables were collected from a prospectively maintained institutional database and patients completed an additional questionnaire with patient-reported outcomes measures.ResultsA total of 350 patients (389 hips) out of 371 (433 hips) with a minimum 10-year follow-up were successfully contacted (94.3% follow-up). Mean age was 53 years, 258 were male (73%). 377 out of 389 hips (96.9%) did not require additional surgery. Gender was significantly related to implant survivorship (males 99.0%, females 90.9%; P < .001). 330 patients (369 hips, 94.8%) were satisfied with their surgery. Males had higher proportion of satisfaction scores (P = .02) and higher modified Harris Hip Score (odds ratio = 2.63 (1.39, 4.98), P = .003). Median modified Harris Hip Score score for non-revised hips was 84.0 [80.0; 86.0] versus those requiring revision, 81.5 [74.0; 83.0], (P = .009).ConclusionAt a minimum 10-year follow-up, hip resurfacing, using an implant with a good track record, demonstrates 99.0% survivorship in male patients with an average age of 52 years. We believe that the continued use of metal-on-metal hip resurfacing arthroplasty in this population is justified by both positive patient reported outcomes and survivorship.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号