首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

OBJECTIVE:

To evaluate changes in respiratory mechanics and tidal volume (VT) in wheezing infants in spontaneous ventilation after performing the technique known as the prolonged, slow expiratory (PSE) maneuver.

METHODS:

We included infants with a history of recurrent wheezing and who had had no exacerbations in the previous 15 days. For the assessment of the pulmonary function, the infants were sedated and placed in the supine position, and a face mask was used and connected to a pneumotachograph. The variables of tidal breathing (VT and RR) as well as those of respiratory mechanics-respiratory system compliance (Crs), respiratory system resistance (Rrs), and the respiratory system time constant (prs)-were measured before and after three consecutive PSE maneuvers.

RESULTS:

We evaluated 18 infants. The mean age was 32 ± 11 weeks. After PSE, there was a significant increase in VT (79.3 ± 15.6 mL vs. 85.7 ± 17.2 mL; p = 0.009) and a significant decrease in RR (40.6 ± 6.9 breaths/min vs. 38.8 ± 0,9 breaths/min; p = 0.042). However, no significant differences were found in the variables of respiratory mechanics (Crs: 11.0 ± 3.1 mL/cmH2O vs. 11.3 ± 2.7 mL/cmH2O; Rrs: 29.9 ± 6.2 cmH2O • mL−1 • s−1 vs. 30.8 ± 7.1 cmH2O • mL−1 • s−1; and prs: 0.32 ± 0.11 s vs. 0.34 ±0.12 s; p > 0.05 for all).

CONCLUSIONS:

This respiratory therapy technique is able to induce significant changes in VT and RR in infants with recurrent wheezing, even in the absence of exacerbations. The fact that the variables related to respiratory mechanics remained unchanged indicates that the technique is safe to apply in this group of patients. Studies involving symptomatic infants are needed in order to quantify the functional effects of the technique.  相似文献   

2.

BACKGROUND:

In some individuals with obstructive sleep apnea (OSA), oronasal continuous positive airway pressure (CPAP) leads to poorer OSA correction than nasal CPAP. The authors hypothesized that this results from posterior mandibular displacement caused by the oronasal mask.

OBJECTIVE:

To test this hypothesis using a mandibular advancement device (MAD) for mandibular stabilization.

METHODS:

Subjects whose OSA was not adequately corrected by oronasal CPAP at pressures for which nasal CPAP was effective were identified. These subjects underwent polysomnography (PSG) CPAP titration with each nasal and oronasal mask consecutively, with esophageal pressure and leak monitoring, to obtain the effective pressure (Peff) of CPAP for correcting obstructive events with each mask (maximum 20 cmH2O). PSG titration was repeated using a MAD in the neutral position. Cephalometry was performed.

RESULTS:

Six subjects with mean (± SD) nasal Peff 10.4±3.0 cmH2O were studied. Oronasal Peff was greater than nasal Peff in all subjects, with obstructive events persisting at 20 cmH2O by oronasal mask in four cases. This was not due to excessive leak. With the MAD, oronasal Peff was reduced in three subjects, and Peff <20 cmH2O could be obtained in two of the four subjects with Peff >20 cmH2O by oronasal mask alone. Subjects’ cephalometric variables were similar to published norms.

CONCLUSION:

In subjects with OSA with higher oronasal than nasal Peff, this is partially explained by posterior mandibular displacement caused by the oronasal mask. Combination treatment with oronasal mask and MAD may be useful in some individuals if a nasal mask is not tolerated.  相似文献   

3.

OBJECTIVE:

To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions.

METHODS:

Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease.

RESULTS:

Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH2O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH2O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers.

CONCLUSIONS:

Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/PEF ratio was attributable to overly rapid inflations and low VT.  相似文献   

4.

Background

The hemodynamic effects of noninvasive ventilation with positive pressure in patients with pulmonary hypertension without left ventricular dysfunction are not clearly established.

Objectives

Analyze the impact of increasing airway pressure with continuous positive airway pressure on hemodynamic parameters and, in particular, on cardiac output in patients with variable degrees of pulmonary hypertension.

Methods

The study included 38 patients with pulmonary hypertension caused by mitral stenosis without left ventricular dysfunction or other significant valvulopathy. The hemodynamic state of these patients was analyzed in three conditions: baseline, after continuous positive pressure of 7 cmH2O and, finally, after pressure of 14 cmH2O.

Results

The population was composed of predominantly young and female individuals with significant elevation in pulmonary arterial pressure (mean systolic pressure of 57 mmHg). Of all variables analyzed, only the right atrial pressure changed across the analyzed moments (from the baseline condition to the pressure of 14 cmH2O there was a change from 8 ± 4 mmHg to 11 ± 3 mmHg, respectively, p = 0.031). Even though there was no variation in mean cardiac output, increased values in pulmonary artery pressure were associated with increased cardiac output. There was no harmful effect or other clinical instability associated with use application of airway pressure.

Conclusion

In patients with venocapillary pulmonary hypertension without left ventricular dysfunction, cardiac output response was directly associated with the degree of pulmonary hypertension. The application of noninvasive ventilation did not cause complications directly related to the ventilation systems.  相似文献   

5.

Background

Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the “tidaling phenomenon” in the bottle can be reflective of the extent of patient’s recovery.

Objectives

However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube.

Methods

The device is made of a pressure sensor with an operating range between −100 to +100 cmH2O and an amplifying using the “Wheatstone bridge” concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector.

Results

The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O.

Conclusions

This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system.  相似文献   

6.
High-frequency oscillation is a novel form of ventilation increasingly being used to treat refractory hypoxic respiratory failure resulting from acute lung injury or acute respiratory distress syndrome. Although there is no known relationship between airway pressure and transpulmonary pressure during conventional mechanical ventilation, no study has attempted to determine transpulmonary pressure during high-frequency oscillation.

BACKGROUND:

High-frequency oscillation (HFO) is used for the treatment of refractory hypoxic respiratory failure.

OBJECTIVE:

To demonstrate that the mean transpulmonary pressure (PL) cannot be inferred from mean airway pressure (mPaw).

METHODS:

In seven patients already undergoing HFO for refractory acute respiratory distress syndrome, esophageal pressure (Pes) was measured using an esophageal balloon catheter. Pleural pressure (Ppl) and PL were calculated from Pes.

MAIN RESULTS:

In the seven patients (mean [± SD] age 59±9 years) treated with HFO at 5±1 Hz and amplitude 75±10 cmH2O, the mPaw was 27±6 cmH2O, Ppl was 9±6 cmH2O and PL was 18±11 cmH2O. Successful catheter placement and measurement of Pes occurred in 100% of subjects. There was no correlation between PL and mPaw. The majority of subjects required hemodynamic support during the use of HFO; the frequency and degree of support during the study period was no different than that before the study.

CONCLUSION:

The present report is the first to describe measuring Pes and calculating Ppl during HFO for acute respiratory distress syndrome. While both current guidelines and recent trials have titrated treatment based on mPaw and oxygenation, there is wide variability in PL during HFO and PL cannot be predicted from mPaw.  相似文献   

7.

BACKGROUND:

Despite the widespread clinical use of cyclooxygenase (COX) inhibitors, dilemmas regarding the potential impact of these drugs on the cardiovascular system persist.

OBJECTIVE:

To estimate the effects of different COX inhibitors (meloxicam, acetylsalicylic acid [ASA] and SC-560) on cardiac function and coronary flow in isolated rat hearts, with special focus on the L-arginine/nitric oxide system.

METHODS:

The hearts of eight-week-old male Wistar albino rats (n=72; 12 rats per group; body mass 180 g to 200 g) were retrogradely perfused according to the Langendorff technique at gradually increased perfusion pressure (40 cmH2O to 120 cmH2O). After control experiments, the hearts were perfused with the following drugs: 100 μM ASA, alone or in combination with 30 μM N(ω)-nitro-L-arginine monomethyl ester (L-NAME), 0.3 μM meloxicam with or without 30 μM L-NAME, 3 μM meloxicam with or without 30 μM L-NAME, 30 μM L-NAME and 0.25 μM SC-560. In the control and experimental groups, the following parameters of heart function were continuously recorded: maximum rate of left ventricular pressure development, minimum rate of left ventricular pressure development, systolic left ventricular pressure, diastolic left ventricular pressure, heart rate and mean blood pressure. Coronary flow was measured flowmetrically. The amount of released NO2 was determined spectrophotometrically in coronary venous effluent.

RESULTS:

While meloxicam and SC-560 were found to have an adverse influence on cardiac function and coronary perfusion, ASA did not negatively affect the intact model of the heart.

CONCLUSION:

It appeared that interaction between COX and the L-arginine/nitric oxide system truly exists in coronary circulation and may explain the causes of the observed effects.  相似文献   

8.

OBJECTIVE:

To investigate the acute effects of intravenous administration of cigarette smoke extract (CSE) on histological, inflammatory, and respiratory function parameters in rats, as well as to compare this potential acute lung injury (ALI) model with that with the use of oleic acid (OA).

METHODS:

We studied 72 Wistar rats, divided into four groups: control (those injected intravenously with saline); CSE (those injected intravenously with CSE and saline); OA (those injected intravenously with saline and OA); and CSE/OA (those injected intravenously with CSE and OA).

RESULTS:

Mean lung compliance was significantly lower in the OA and CSE/OA groups (2.12 ± 1.13 mL/cmH2O and 1.82 ± 0.77 mL/cmH2O, respectively)than in the control group (3.67 ± 1.38 mL/cmH2O). In bronchoalveolar lavage fluid, the proportion of neutrophils was significantly higher in the OA and CSE/OA groups than in the control group, as was the activity of metalloproteinases 2 and 9. Pulmonary involvement, as assessed by morphometry, was significantly more severe in the OA and CSE/OA groups (72.9 ± 13.8% and 77.6 ± 18.0%, respectively) than in the control and CSE groups (8.7 ± 4.1% and 32.7 ± 13.1%, respectively), and that involvement was significantly more severe in the CSE group than in the control group.

CONCLUSIONS:

The intravenous administration of CSE, at the doses and timing employed in this study, was associated with minimal ALI. The use of CSE did not potentiate OA-induced ALI. Additional studies are needed in order to clarify the potential role of this model as a method for studying the mechanisms of smoking-induced lung injury.  相似文献   

9.

Background

Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP.

Objective

The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF.

Methods

Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode.

Results

CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min).

Conclusion

NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome.  相似文献   

10.

OBJECTIVE:

To determine the efficacy of chest compression accompanied by a 10-cmH2O increase in baseline inspiratory pressure on pressure support ventilation, in comparison with that of aspiration alone, in removing secretions, normalizing hemodynamics, and improving respiratory mechanics in patients on mechanical ventilation.

METHODS:

This was a randomized crossover clinical trial involving patients on mechanical ventilation for more than 48 h in the ICU of the Porto Alegre Hospital de Clínicas, in the city of Porto Alegre, Brazil. Patients were randomized to receive aspiration alone (control group) or compression accompanied by a 10-cmH2O increase in baseline inspiratory pressure on pressure support ventilation (intervention group). We measured hemodynamic parameters, respiratory mechanics parameters, and the amount of secretions collected.

RESULTS:

We included 34 patients. The mean age was 64.2 ± 14.6 years. In comparison with the control group, the intervention group showed a higher median amount of secretions collected (1.9 g vs. 2.3 g; p = 0.004), a greater increase in mean expiratory tidal volume (16 ± 69 mL vs. 56 ± 69 mL; p = 0.018), and a greater increase in mean dynamic compliance (0.1 ± 4.9 cmH2O vs. 2.8 ± 4.5 cmH2O; p = 0.005).

CONCLUSIONS:

In this sample, chest compression accompanied by an increase in pressure support significantly increased the amount of secretions removed, the expiratory tidal volume, and dynamic compliance. (ClinicalTrials.gov Identifier:NCT01155648 [http://www.clinicaltrials.gov/])  相似文献   

11.

Objective

Prospective randomized controlled study was conducted to explore the effects and safety of prophylactic use of noninvasive positive pressure ventilation (NPPV) in post-thoracic surgery (PTS) patients, especially on the lung re-expansion, lung function change and postoperative pulmonary complications (PPCs).

Methods

Fifty PTS patients met the inclusion criterion were enrolled in the study. All subjects were randomly divided into conventional treatment (control) group and NPPV group. NPPV group received intermittent NPPV therapy in first three days of PTS. BiPAP ventilator was used with S/T mode in the study. The average IPAP was (13±3.2)cmH2O (ranged from 7 to 18 cmH2O) and EPAP was 4cmH2O. Total ventilation time was (13.5±4.9) hours (ranged from 6.5 to 23 hours). PPCs rate, lung re-expansion, the volume of residual cavity, lung function and tolerance to NPPV were assessed with chest roentgenography, CT scan, lung function testing and clinical evaluation before and one week after surgery.

Results

1. There was no significant difference of total PPCs rate during hospitalization between the two groups (5/23 in NPPV group vs 6/27 in control group, P= 0.967). Multiple factorial logistic regression analysis showed that COPD was a risk factor for PPCs (B=1.705, P=0.027). 2. Compared with control group, NPPV therapy reduced inadequate lung expansion rate (3/23 vs 13/27, P=0.008) and volume of residual cavity calculated with CT scan [(31.9±71.7)ml vs (63.6±78.3)ml, P=0.02]. However, there were no significant difference in the change of lung function parameters after operation between the two groups (all P>0.05). No significant adverse effects of NPPV were found in the present study.

Conclusions

In the current study of prophylactic application of NPPV in post-thoracic surgery patients, the use of NPPV resulted in improved lung re-expansion, but had no significant effects on post-operative pulmonary complications and lung functions.  相似文献   

12.

Background

The mortality rate of patients with acute respiratory distress syndrome (ARDS) is still high despite the use of protective ventilatory strategies. We sought to examine the pharmacological effects of glutamine (GLN) in a two-hit model of endotoxin-induced inflammation followed by ventilator-induced lung injury (VILI). We hypothesized that the administration of GLN ameliorates the VILI.

Methods

Sprague-Dawley rats were anesthetized and given lipopolysaccharide (LPS) intratracheally as a first hit to induce lung inflammation, followed 24 h later by a second hit of mechanical ventilation (MV) with either low tidal volume (6 mL/kg) with 5 cmH2O of positive end-expiratory pressure (PEEP) or high tidal volume (22 mL/kg) with zero PEEP for 4 h. GLN or lactated Ringer’s solution as the placebo was administered intravenously 15 min prior to MV.

Results

In the LPS-challenged rats ventilated with high tidal volume, the treatment with GLN improved lung injury indices, lung mechanics and cytokine responses compared with the placebo group.

Conclusions

The administration of GLN given immediately prior to MV may be beneficial in the context of reducing VILI.  相似文献   

13.

Summary

Background and objectives

In the Hemodialysis (HEMO) Study, observed small decreases in achieved equilibrated Kt/Vurea were noncausally associated with markedly increased mortality. Here we examine the association of mortality with modeled volume (Vm), the denominator of equilibrated Kt/Vurea.

Design, setting, participants, & measurements

Parameters derived from modeled urea kinetics (including Vm) and blood pressure (BP) were obtained monthly in 1846 patients. Case mix–adjusted time-dependent Cox regressions were used to relate the relative mortality hazard at each time point to Vm and to the change in Vm over the preceding 6 months. Mixed effects models were used to relate Vm to changes in intradialytic systolic BP and to other factors at each follow-up visit.

Results

Mortality was associated with Vm and change in Vm over the preceding 6 months. The association between change in Vm and mortality was independent of vascular access complications. In contrast, mortality was inversely associated with V calculated from anthropometric measurements (Vant). In case mix–adjusted analysis using Vm as a time-dependent covariate, the association of mortality with Vm strengthened after statistical adjustment for Vant. After adjustment for Vant, higher Vm was associated with slightly smaller reductions in intradialytic systolic BP and with risk factors for mortality including recent hospitalization and reductions in serum albumin concentration and body weight.

Conclusions

An increase in Vm is a marker for illness and mortality risk in hemodialysis patients.  相似文献   

14.

OBJECTIVE:

To investigate the hemodynamic and outcome effects of implementing prophylactic positive end-expiratory pressure (PEEP) versus zero end-expiratory pressure (ZEEP) in patients during the postintubation period in the emergency setting.

METHODS:

The present study was a prospective, single-centre, interventional, single-blinded randomized trial performed in a 16-bed medical intensive care unit. The study cohort consisted of consecutive patients who urgently required intubation. During the postintubation period, patients received either 5 cmH2O PEEP or ZEEP. The primary aim was to assess the variation in mean arterial pressure (MAP) from baseline up to 90 min postintubation. The secondary aim was to determine the mean duration of intubation, level of MAP support after intubation and 28-day mortality.

RESULTS:

Seventy-five consecutive patients with similar mean (± SD) baseline characteristics and preintubation MAP (76±18 mmHg in the ZEEP group and 78.5±23 mmHg in the PEEP group, P=Not significant [NS]) were studied. The final analysis was performed in 33 patients in the ZEEP group and 30 patients in the PEEP group. Regarding outcome measures following intubation, delta MAP (ie, the difference between the lowest MAP values from baseline) was not differentially affected in either group (P=NS); the mean durations of intubation were similar (ZEEP 9.2±8.5 days versus PEEP 9.2±8.8 days, P=NS); 28-day mortality was not discriminative (ZEEP 14 of 33, PEEP nine of 30; P=NS); and levels of MAP support after intubation were comparable between the two groups. .

CONCLUSION:

In the present trial, there was no evidence that implementing a prophylactic PEEP of 5 cmH2O adversely affects short-term hemodynamics or outcome in medical intensive care patients during the postintubation period.  相似文献   

15.

Objective:

Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM.

Methods:

This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization.

Results:

Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly.

Conclusions:

The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.  相似文献   

16.

Background

T follicular helper (TFH) cells reside in the light zone of germinal centers and are considered the cell of origin of angioimmunoblastic T-cell lymphoma. Recently, CXCL13, PD-1 and SAP were described as useful markers for TFH cells and angioimmunoblastic T-cell lymphoma but also reported in some peripheral T-cell lymphomas, not otherwise specified.

Design and Methods

In the present study the expression pattern of ICOS protein was investigated by immunohistochemistry-based techniques in routine sections of normal lymphoid tissues and 633 human lymphomas.

Results

Cells strongly positive for ICOS were restricted to the light zone of germinal centers and co-expressed TFH-associated molecules. In addition, weak to moderate ICOS expression was observed in a small proportion of FOXP3-positive cells. In lymphomas, ICOS expression was confined to angioimmunoblastic T-cell lymphoma (85/86), peripheral T-cell lymphomas of follicular variant (18/18) and a proportion of peripheral T-cell lymphomas, not otherwise specified (24/56) that also expressed other TFH-associated molecules.

Conclusions

ICOS is a useful molecule for identifying TFH cells and its restricted expression to angioimmunoblastic T-cell lymphoma and a proportion of peripheral T-cell lymphomas, not otherwise specified (showing a TFH-like profile) suggests its inclusion in the antibody panel for diagnosing TFH-derived lymphomas. Our findings provide further evidence that the histological spectrum of TFH-derived lymphomas is broader than previously assumed.  相似文献   

17.
18.

Background

The surgical management of Lutembacher syndrome is straight forward but percutaneous management, though technically demanding, is always desirable.

Methods

A 17 year old unmarried female presented with severe Mitral stenosis and a 19 mm almost circular Ostium secundum ASD with moderate pulmonary artery hypertension and dilated right sided chambers. She was managed in a staged manner. Percutaneous trans mitral commissurotomy (PTMC) was done first, using a 26 mm Inoue balloon catheter set, and after 48 h, ASD was closed with a 20 mm Cocoon Septal Occluder.

Results

The mitral valve area increased after PTMC from 0.8 cm2 to 2.1 cm2 and QP/QS decreased from 4.9 to 2. ASD was successfully closed under echocardiographic and fluoroscopic guidance.

Conclusion

Percutaneous management of the Lutembacher syndrome (PTMC and ASD device closure) is an effective and low risk procedure and avoids considerable morbidity and mental trauma for the patients.  相似文献   

19.

Background

Cardiovascular disease in Asia has reached epidemic proportions in recent years. Use of drug eluting stents in Asians has rapidly expanded with varying penetration rates across different countries. The XIENCE V® INDIA Study included ‘real world’ patients who underwent XIENCE V® stent implantation to assess short and intermediate term outcomes in Indian patients with diverse risk factors.

Objective

To evaluate 3-year clinical outcomes in a cohort of ‘real world’ Indian patients with CAD being treated with XIENCE V® Everolimus Eluting Coronary Stent System.

Methods

1000 patients were enrolled from 18 sites in India between June 2008 and March 2009. Patients were included if their index procedures were completed using only XIENCE V®. There were no clinical or angiographic exclusions. An independent Clinical Events Committee adjudicated all endpoint-related events. The primary endpoint was stent thrombosis rate annually through to 3 years as defined by the Academic Research Consortium criteria. The co-primary endpoint was the composite rate of cardiac death and myocardial infarction at 1 year.

Results

At 1-year the primary endpoint of definite/probable stent thrombosis rate was 0.51%. No additional very late stent thrombosis was reported through a 3-year follow up. The composite endpoint of cardiac death and any myocardial infarction was 1.9%, 2.7% and 3.1% at 1, 2 and 3 years respectively.

Conclusion

Despite the high risk population of coronary artery disease, the use of XIENCE V® in ''real world'' Indian patients was associated with very low clinical event rates upto three years of follow up.  相似文献   

20.

BACKGROUND:

The effectiveness of high-frequency chest wall oscillation (HFCWO) in mucolysis and mucous clearance is thought to be dependant on oscillatory flow rate (Fosc). Therefore, increasing Fosc during HFCWO may have a clinical benefit.

OBJECTIVES:

To examine effects of continuous positive airway pressure (CPAP) on Fosc at two oscillation frequencies in healthy subjects and patients with airway obstruction.

METHODS:

Five healthy subjects and six patients with airway obstruction underwent 12 randomized trials of HFCWO (CPAP levels of 0 cm H2O, 2 cm H2O, 4 cm H2O, 6 cm H2O, 8 cm H2O and 10 cm H2O at frequencies of 10 Hz and 15 Hz) within a body plethysmograph, allowing measurements of changes in lung volume. Fosc was measured by reverse plethysmography using a 20 L isothermic chamber near the mouth. At the end of each randomized trial, an inspiratory capacity manoeuvre was used to determine end-expiratory lung volume (EELV).

RESULTS:

EELV increased significantly (P<0.05) with each level of CPAP regardless of oscillation frequency. Fosc also significantly increased with CPAP (P<0.05) and it was correlated with EELV (r=0.7935, P<0.05) in obstructed patients but not in healthy subjects (r=0.125, P=0.343). There were no significant differences in perceived comfort across the levels of CPAP.

CONCLUSIONS:

Significant increases in Fosc with CPAP-induced increases in lung volume were observed, suggesting that CPAP may be useful as a therapeutic adjunct in patients who have obstructive airway disease and who require HFCWO.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号