共查询到20条相似文献,搜索用时 31 毫秒
1.
Grand DJ Atalay MA Cronan JJ Mayo-Smith WW Dupuy DE 《European journal of radiology》2011,79(2):e133-e136
Purpose
To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm.Materials/methods
86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below.Results
Average fluoroscopy time using CTF was 28.2 s compared to 35.0 s for EMN (p = 0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p = 0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p = 0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p = 0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p = 0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p = 0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p = 0.4).Conclusions
EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN. 相似文献2.
Christoph Thomas Hanne WojtczykHansjörg Rempp Stephan ClasenMarius Horger Christoph von LaßbergJan Fritz Claus D. ClaussenPhilippe L. Pereira 《European journal of radiology》2011,79(3):353-358
Objective
To assess the artefact properties of a MR-compatible carbon fibre needle with a nitinol mandrin in vitro and to report first clinical experiences.Materials and methods
In vitro, the carbon fibre/nitinol needle was imaged at different angles against the main magnetic field (1.5 T open bore magnet). A gradient echo MR fluoroscopy sequence (GRE: TR 9.3 ms, TE 3.12 ms, bandwidth 200 Hz/pixel, flip-angle 12°) and a fast turbo spin echo sequence (FSE: TR 412 ms, TE 9.7 ms, bandwidth 200 Hz/pixel, flip-angle 150°) were used. Artefact width, needle intensity contrast and needle tip location errors were assessed. In vivo, lumbar periradicular corticosteroid injections and one sclerotherapy were performed with carbon fibre needles (10 procedures) and with titanium alloy needles (2 procedures). The artefact sizes and contrasts were measured.Results
In vitro, artefact diameters of the carbon fibre needle ranged from 3.3 to 4.6 mm, contrasts from 0.11 to 0.52, with larger artefact contrasts and widths with the GRE sequence. Needle tip location errors of −2.1 to −2.8 mm were observed. Decreasing angles to the main field lead to smaller artefacts. In vivo, the carbon fibre/nitinol needle produced smaller artefacts (mean width FSE/GRE: 2.8 mm/4.6 mm) with lower contrast (0.30-0.42) than the titanium alloy needle (mean width FSE/GRE: 4.1 mm/7.5 mm, contrast 0.60-0.73).Conclusions
The carbon fibre/nitinol needle is useful for performing MR-guided interventions at 1.5 T, producing more subtle artefacts than a titanium alloy needle, but with an incomplete depiction and thus inaccurate localization of the needle tip. 相似文献3.
Kotsianos-Hermle D Wirth S Fischer T Hiltawsky KM Reiser M 《European journal of radiology》2009,71(1):102-108
Objectives
The feasibility, image quality, and diagnostic potential of the prototype of an automated ultrasound (US) breast scanner were examined.Methods
Ninety-seven patients with suspicious breast lesions had mammograms, manual US, and an automated breast US. The data were evaluated according to the breast imaging reporting and data system (BIRADS) classification, image quality, and amount to diagnostic information. All lesions were confirmed histological.Results
The image quality of the three-dimensional (3D) data sets was equal to or satisfactory compared with cross-sectional images from manual US in at least 72% of cases (p < 0.05). The diagnostic information was equal or superior in at least 63% of cases (p < 0.05).Conclusions
Standardized 3D US scanning is a promising diagnostic adjunct to mammography, but is no substitute for manual US at the current stage of development. 相似文献4.
Yamauchi Y Izumi Y Nakatsuka S Inoue M Hayashi Y Mukai M Nomori H 《European journal of radiology》2011,79(2):e85-e89
Objective
The diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity (GGO) pulmonary lesions was evaluated.Materials and methods
Out of 90 patients who underwent CT fluoroscopy-guided core needle biopsy of GGO lesions at our institution, the biopsy results and the final diagnoses were retrospectively compared in 67 patients with available data (one lesion per patient). Diagnostic performance was also compared according to the lesion size (≤10 mm (n = 8) versus 11-20 mm (n = 42) versus >20 mm (n = 17)), the percentage of GGO component (50-90% (n = 31) versus >90% (n = 36)), and the length of needle path (≤7 cm (n = 45) versus >7 cm (n = 22)). Finally, all 90 cases were reviewed for complications.Results
The overall sensitivity, specificity, and accuracy were 97%, 100%, and 97%, respectively. The diagnostic sensitivity and accuracy tended to be lower in smaller lesions (≤10 mm; 86 and 88%, 11-20 mm; 97 and 98%, >20 mm; 100 and 100%, respectively, p > 0.05), and in lesions with lower percentage of GGO component (50-90%; 93 and 94%, >90%; 100 and 100%, respectively, p = 0.21), but statistical significances were not reached. The sensitivity and accuracy were not significantly affected by the length of needle path (≤7 cm; 98 and 98%, >7 cm; 95 and 96%, respectively, p = 1.00). Fourteen patients (16%) developed pneumothoraces, and 13 patients (14%) experienced mild hemoptysis, all of which resolved conservatively.Conclusion
The diagnostic performance was satisfactory, and it was considered that the procedure was appropriate for GGO lesions regardless of lesion size, the percentage of GGO component, or the length of needle path. The procedure was also feasible without any major complications. 相似文献5.
US-guided interventional joint procedures in patients with rheumatic diseases—When and how we do it?
B. Gonçalves C. AmbrosioS. Serra F. AlvesA. Gil-Agostinho F. Caseiro-Alves 《European journal of radiology》2011,79(3):407-414
Objective
To describe the main indications and the technical steps to perform ultrasound guided procedures in patients with rheumatic diseases. To access procedures accuracy, safety and effectiveness.Materials and methods
27 patients with pain related to articular complications of rheumatic diseases and according to previous radiographic or US exam were submitted to several US-guided procedures. 42% of patients (n = 11) had rheumatoid arthritis, 11% (n = 3) spondyloarthropathies, 18% (n = 5) psoriatic arthritis, 15% (n = 4) undifferentiated arthritis, 3% (n = 1) Sjögren syndrome and 11% (n = 3) had gout.Described procedures are synovial biopsies, intra-articular injections of corticosteroids, radiation synovectomy and synovial cysts drainage procedures. When a therapeutical procedure was made, patients were evaluated by 2 rheumatologists.Corticosteroids used were Prednisolone and Triamcinolone. Yttrium-90 was used for synovectomy.Results
In all cases success was achieved with correct needle placement inside the joint. After injection/aspiration symptoms successfully solved with all patients improving their health status. No complications were recorded during follow-up period.Conclusions
US-guidance is very reliable to afford a safety procedure always checking the injection, biopsy or aspiration. Guided-biopsy has high success rates obtaining several samples. Thus is also possible to use more powerful/long acting therapeutic drugs aggressive to extra-articular structures avoiding complications. 相似文献6.
Lingfeng Min Xingxiang Xu Yong Song Ben-Dov Issahar Jingtao Wu Le Zhang Qian Huang Mingxiang Chen 《European journal of radiology》2013
Purpose
To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions.Materials and methods
Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique.Results
A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver.Conclusion
Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study. 相似文献7.
Purpose
In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification.Methods and Materials
Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms.Results
In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4 mm on average with maximum values of over 10 mm because of imaging artifacts.Conclusions
A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. 相似文献8.
Husain ZA Mahmood U Hanlon A Neuner G Buras R Tkaczuk K Feigenberg SJ 《Brachytherapy》2011,10(6):479-485
Purpose
The 2002 Food and Drug Administration approval of the MammoSite catheter (Hologic, Inc., Beford, MA) led to a surge of interest in accelerated partial breast irradiation (APBI). Until recently, guidelines as to the optimal candidates for this treatment were unavailable. We performed a patterns-of-care analysis for patients undergoing breast brachytherapy and compared these results with the American Society for Radiation Oncology (ASTRO) consensus statement.Methods and Materials
The Surveillance, Epidemiology, and End Results database was used to examine female breast cancer patients treated with brachytherapy between 2002 and 2007. The patients were then categorized into suitable, cautionary, and unsuitable groups based on the ASTRO guidelines.Results
We identified 4172 female breast cancer patients treated within the stated years. The number of brachytherapy cases increased nearly 10-fold over the time period studied from 163 in 2002 to 1427 in 2007 (p < 0.0001). Patients with data missing were excluded, leaving a total of 3593 patients available for analysis. The mean patient age was 64 years. Most patients had small (<2 cm in 80.9%) estrogen receptor-positive (86.7%) invasive (88.6%) tumors. The percentage of patients treated for ductal carcinoma in situ increased with time (p < 0.001), whereas the percentage of patients treated with positive lymph nodes decreased with time (p < 0.001). Using the data available, 1369 (38.1%), 1563 (43.5%), and 661 (18.3%) patients were characterized as suitable, cautionary, and unsuitable, respectively.Conclusions
More than 60% of patients who received APBI via brachytherapy would fall into the ASTRO cautionary or unsuitable groupings. This is the largest patterns-of-care analysis for APBI patients and serves as a baseline for future comparison. 相似文献9.
Hasan I. Megally Waleed S.H. Farrag Mostafa Sad Khalil 《The Egyptian Journal of Radiology and Nuclear Medicine》2011,42(1):43-46
Purpose
To evaluate the efficacy and safety of ultrasound technology for infraclavicular brachial plexus block in chronic renal failure patients undergoing arterio-venous shunt operations.Material and methods
Our study included 40 patients with fulfilled clinical criteria of chronic renal failure. All patients (32 RT and 8 LT sided) were subjected to infraclavicular block using ultrasound visualization with 7.5-10 MHz linear probe. The anesthetic mixture consisted of 20 ml lidocain hydrocarbonate 2% and 20 ml of plain bupivacaine 0.5%. Sensory block, motor block and supplementation rate were evaluated for the musculocutaneous, median, radial and ulnar nerves.Results
Surgical anesthesia was achieved without supplementation in 38 patients (95%) and 2 patients needed supplementation with infiltration anesthesia (5%). No patient in the study needed general anesthesia. Duration of surgery, administration, onset and complete blocks in minutes were (165 ± 11.7, 11 ± 4.5, 4.5 ± 1.5 and 8.5 ± 3.4), respectively. No vascular injury was reported in this study.Conclusion
We concluded that real-time ultrasound imaging during infraclavicular brachial plexus blocks can facilitate nerve localization, needle placement and provide high success rate. Also it improves safety for ICBPB. 相似文献10.
Purpose
We evaluated the feasibility of a using urine sensor for voiding cystourethrography (VCUG) and its implications for fluoroscopy time reduction.Materials and methods
Institutional Review Board approved the study protocol. Study population included children less than 5 years old referred to our institution for VCUG. Patients with known vesicoureteral reflux or any pacing device were excluded from the study. The urine sensor consists of an electrode that senses the fluid, an electrical circuit and an indicator to provide visual signal. The urine sensor electrode was placed on the medial thigh in the proximity of the catheter close to the urethral opening, but without direct contact to it. A standard VCUG examination was performed with retrograde filling of the urinary bladder. Once the bladder was full, fluoroscopy of the voiding stage was initiated when the indicator blinked. Peak kV and fluoroscopy time were recorded.Results
Seven patients underwent VCUG with urine sensor and 22 patients without urine sensor. The urine sensor provided a reliable indication of voiding onset. The fluoroscopy time was significantly shorter with urine sensor use (1.99 min) than without urine sensor use (4.33 min) (p = 0.001). In patients with normal VCUG, fluoroscopy time was also significantly shorter with urine sensor use (2.13 min) than without urine sensor use (4.39 min) (p < 0.001).Conclusion
VCUG studies with the help of the urine sensor are feasible and its use may result in significant reduction in fluoroscopy time. 相似文献11.
In Jae Lee Young-A Bae Ki-Suck Jung Kwanseop Lee Sang Hoon Bae 《European journal of radiology》2010,73(3):551-554
Purpose
To evaluate 5 years results of percutaneous needle aspiration biopsy (PCNAB) for lung lesions and usefulness of the reaspiration or rebiopsy of lung lesions (repeat PCNAB).Materials and methods
Six hundred and fifteen cases of PCNAB (591 initial PCNAB and 24 repeat PCNAB) performed under the CT or fluoroscopy guidance in 591 patients was enrolled. The procedure was done using an automated biopsy gun with a 20-G needle (519 cases) or a 20-G aspiration needle (96 cases). The pathologic results, type and rate of complications in the initial and repeat PCNAB were evaluated. The pathologic agreement rate between the initial and repeat PCNAB, and reasons of the repeat PCNAB were also evaluated.Results
Of the 615 PCNAB cases, 345 cases yielded tumors and 270 cases yielded non-tumorous lesions. Of the tumorous lesions, 307 cases were primary lung malignancies, 34 cases were metastases, and 4 were benign tumors. The repeat PCNAB rate was 4.1% (24/591). There was no statistically significant difference between automated gun biopsy and needle aspiration as a biopsy tool for calling repeat PCNAB (p = 0.4034). The causes for a repeat PCNAB were inconclusive (n = 14) and unexpected pathologic results (n = 10). Of the 14 pathologically inconclusive cases on initial PCNAB, 9 cases revealed malignancy after the repeat PCNAB. Of the 10 cases with unexpected pathologic results on initial PCNAB, 3 cases yielded different pathologic results on repeat PCNAB from initial PCNAB. The cumulative complication rate of PCNAB was 11.4% (70/615).Conclusion
PCNAB was useful for the diagnosis of pulmonary lesions. Repeat PCNAB might be helpful for the exact diagnosis of lung lesions where initial PCNAB yields inconclusive or unexpected pathologic results. 相似文献12.
Eugenio Rimondi Giuseppe RossiTommaso Bartalena Rosanna CiminariMarco Alberghini Pietro RuggieriCostantino Errani Andrea AngeliniTeresa Calabrò Caterina Novella AbatiAlba Balladelli Cristina TranfagliaAndreas F. Mavrogenis Daniel VanelMario Mercuri 《European journal of radiology》2011,77(1):34-42
Introduction
Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications.Materials and methods
We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors’ institution. The results obtained are subject of this paper.Results
In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome.Conclusion
This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system. 相似文献13.
Purpose
The purpose of this multicenter study was to determine the doses received by patients during interventional neuroradiology procedures and to consider establishing reference standards.Materials and methods
A retrospective study of nine interventional neuroradiology departments was conducted. Seven diagnostic (cerebral and spinal angiography) and therapeutic (embolization and vertebroplasty) procedures were reviewed. For each procedure, three dosimetric parameters were recorded: dose-area product (DAP), fluoroscopy time, and number of images.Results
Results showed interdepartment variations, up to four-fold for diagnostic procedures and seven-fold for therapeutic procedures. However, applying the 75th percentile method to the entire dataset, reference standards can be proposed for six types of procedures including diagnostic cerebral angiography (230 Gy cm2), follow-up selective cerebral angiography (80 Gy cm2), aneurysm embolization (350 Gy cm2), AVM embolization (440 Gy cm2). Reference standards are also proposed with regards to fluoroscopy time and number of images.Conclusion
Such standards are useful for clinicians to evaluate and improve their practices. 相似文献14.
Ralf-Thorsten Hoffmann Tobias F. Jakobs Constanze H. Kubisch Christoph G. Trumm Christof Weber Hans-Roland Duerr Thomas K. Helmberger Maximilian F. Reiser 《European journal of radiology》2010,73(2):374-379
Purpose
This study aimed to determine the success and complication rates of radiofrequency ablation (RFA) in treatment of osteoid osteoma (OO) and duration of pain relief. Furthermore value of bone biopsy prior to the RFA was evaluated.Materials and methods
Within 61 months 39 patients (23 male, 16 female, 7-53 years, mean 18.7 years, median 17 years) suffering from osteoid osteoma were treated. Lesions were located in femur (n = 20), tibia (n = 10), spine (n = 5), humerus (n = 1), radius (n = 1), talus (n = 1) and pelvis (n = 1). In children, RFA was performed under general anaesthesia, in adults conscious sedation was preferred. In 29 of 39 (74%) lesion biopsies were obtained. Cooling of skin was performed in OOs located in bones with minor soft tissue covering (tibia, radius) and saline flushing via an additional needle was performed if the OO was adjacent to nerval structures. Primary success rate, complications, symptom-free interval, follow-up and biopsy results were evaluated.Results
Within observation period (1-61 months; median: 32 months) 38 of 39 patients were successfully treated and had no more complaints. In 3 of 38 patients relapse occurred after 1, 14 and 32 months and RFA was repeated. Two major complications (broken drill, infection) and 2 minor complications (hematoma, prolonged pain) were observed. Biopsy was able to prove diagnosis in 14 of 29 (48%) cases.Conclusions
Biopsy prior to treatment is not mandatory due to a remarkable amount of false negative findings in clinically and morphologically unambiguous cases of OO. RFA is a highly effective, efficient, minimally invasive and safe method for the treatment of OO. 相似文献15.
Atri M McGregor C McInnes M Power N Rahnavardi K Law C Kiss A 《European journal of radiology》2009,71(1):135-140
Purpose
To compare accuracy of non-enhanced CT (NECT) (no oral or IV contrast) and enhanced CT (ECT) (IV enhanced only) to diagnose small bowel obstruction and evaluate reviewer's experience impact.Materials and methods
Ninety-nine adult patients underwent 105 NECT and ECT (6 patients had 2 examinations) on a four-detector CT. An abdominal radiologist, an abdominal imaging fellow, a second-year radiology resident retrospectively reviewed NECTs and ECTs separately and independently blinded to outcome. Discrepancy of diameter of proximal and distal small bowel ± a transition was considered indication of mechanical bowel obstruction. Reference standard was surgery in 26 and chart review in 79.Results
Mechanical obstruction was present in 56% (59/105). The average sensitivity, specificity, negative and positive predictive and accuracy values for NECT were 88.1% (CI: 80-96%), 77% (CI: 65-89%), 83.0% (CI: 72-95%), 83% (CI: 74-92%), and 83% (CI: 76-90%) with no significant difference between three reviewers. The corresponding numbers for ECT were 87.6% (CI: 79-96%), 75% (CI: 63-88%), 82.6.0% (CI: 71-94%), 82.1% (CI: 73-92%), and 82% (CI: 75-90%) (p > 0.5). Area under curve (AUC) of ROC curves of three reviewers did not show significant statistical difference (p > 0.5).Conclusions
NECT and ECT have comparable accuracy to diagnose mechanical small bowel obstruction and can be interpreted by reviewers with different levels of expertise. 相似文献16.
Zampa V Bargellini I Ortori S Faggioni L Cioni R Bartolozzi C 《European journal of radiology》2009,71(3):527-535
Purpose
To compare the results of dynamic gadolinium-enhanced magnetic resonance imaging (MRI), unenhanced MRI and computed tomography (CT), in terms of nidus conspicuity and diagnostic confidence of osteoid osteoma in atypical sites.Materials and methods
CT and MR (nonenhanced T1- and T2-weighted and dynamic MRI) images of 19 patients with histologically proven osteoid osteoma located in atypical sites were retrospectively reviewed. Time-enhancement curves of the nidus and the adjacent bone marrow were generated. Images from each technique were scored for nidus conspicuity by two independent radiologists. Another blinded radiologist was asked to assess final diagnosis of the bone lesion on MR and CT images, independently.Results
In all cases, nidus contrast uptake started in the arterial phase and was higher compared to the surrounding bone marrow. Dynamic MRI significantly increased nidus conspicuity compared to nonenhanced MRI (P < .0001) and CT (P = .04). In 6/19 (31.6%) cases nidus conspicuity was higher at dynamic MRI compared to CT. Confident diagnosis of osteoid osteoma was achieved in all patients with MRI and in 10/19 (52.6%) patients with CT.Conclusion
In patients with osteoid osteoma located in atypical sites, dynamic MRI increases nidus conspicuity, allowing confident diagnosis. 相似文献17.
Said A. Elmonem Hazim I. Tantawy Ahmad S. Ragheb Nawel E.H. MatarIsmail Tantawi 《The Egyptian Journal of Radiology and Nuclear Medicine》2011,42(1):35-42
Background
Although partial splenic embolization (PSE) has been widely used for treatment of leucocytopaenia and thrombocytopaenia in cirrhosis, only few studies evaluate both benefits and complications of it.Objective
To evaluate outcome of partial splenic embolization benefits on both platelet and leukocytes counts and its complications in treatment of cirrhotic patients.Patients and methods
Cirrhotic patients with hypersplenism-induced thrombo-cytopenia underwent partial splenic embolization (PSE). From All patients complete history and full clinical examination were taken and subjected to Laboratory investigations. After PSE was performed, the precise extent of embolization was calculated on CT examinations 2 weeks after PSE. Prophylactic antibiotics was given for 5 days after PSE. All patients were then followed up at the outpatient clinic. Peripheral blood cell parameters including white blood cell (WBC), platelet (PLT) and red blood cell (RBC) counts were monitored prior to PSE, on the 3rd, 14th, 30th day after PSE, and subsequently at 3-month intervals during the 2-year follow-up period. The complications associated with PSE were appropriately recorded. All patients underwent abdominal CT scanning before and 2 weeks after PSE.Results
Twenty three patients were included in this study. 13 (57%) males and 10 (43%) females with mean age 42.37 years. PSE was successfully performed in all 23 patients. Post-embolization syndrome 91.3% (21/23) was the most frequent side effect. Other minor complications as puncture site hematoma occurred to one patient at site of femoral artery. Severe complications occurred in eight patients (34.8%). two patients had a large amount of pleural effusion and ascites. One patients developed bacterial peritonitis and died of septicemia. One patient complicated by splenic abscess. One patient had recurrent thrombo-cytopenia and treated by PSE. Portal vein thrombosis was found in one patient. One patient presented with huge splenomegaly and improved after splenectomy. Post-PSE, the platelets and leukocytes counts showed increase in the number. Best results obtained with larger splenic infarction area but in the expense of more major complications.Statistical analysis
Blood parameters were compared using paired t test. P < 0.05 means significant differences.Conclusion
PSE is a useful treatment in patients with hypersplenism caused by cirrhosis. PSE is safe in advanced disease patients, not suitable for splenectomy, with good long-term effect on the hematological parameters and a reduction in bleeding episodes from esophageal varices. 相似文献18.
Dumay-Levesque T Lémery S Dauplat MM Boussion V Dieu V Bailly A Kwiatkowski F Boyer L 《Journal de radiologie》2011,92(3):226-235
Purpose
To evaluate stereotactic core biopsies of the breast with the 10-gauge Vacora® biopsy device.Patients and methods
Retrospective study of 541 procedures in 502 patients performed between 2007 and 2009.Results
The procedure failed in 2 % of cases, non-complicated hematomas occurred in 5 % of cases and unsightly scars in two cases. A clip was deployed in 70 % of cases, successfully in 99 % of cases. The procedure was well tolerated in 88 % of cases. Core biopsies confirmed a benign lesion in 55 % of cases, borderline lesions in 19 % of cases and malignant lesions in 26 % of cases with complementary surgery performed in 40 % of cases. For surgical lesions, sensitivity, specificity, PPV and NPV were 89 %, 100 %, 100 % and 84 % respectively. Atypical ductal dysplasia was under-estimated in 8 % of cases while DCIS was under-estimated in 14 % of cases. After review of the mammograms, 3 % of Bi-Rads 4 lesions were reclassified as Bi-Rads 3 lesions, all benign at core biopsy. Half of these results were from screening mammography programs.Conclusion
Results with the 10-gauge Vacora® biopsy device are similar to reports from the literature, mainly using the Mammotome system, with regards to tolerability and reliability for a lesser cost. 相似文献19.
Purpose
To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode ray tube (CRT) monitor in the detection of interstitial lung markings using a silicon flat-panel-detector direct radiography (DR) and storage phosphor computed radiography (CR) in a clinical setting.Materials and methods
We displayed 39 sets of posteroanterior chest radiographs from the patients who were suspected of interstitial lung disease. Each sets consisted of DR, CR and thin-section CT as the reference standard. Image identities were masked, randomly sorted, and displayed on both five mega pixel (2048 × 2560 × 8 bits) LCD and CRT monitors. Ten radiologists independently rated their confidence in detection for the presence of linear opacities in the four fields of the lungs; right upper, left upper, right lower, and left lower quadrant. Performance of a total 6240 (39 sets × 2 detector systems × 2 monitor system × 4 fields × 10 observers) observations was analyzed by multi-reader multi-case receiver operating characteristic (ROC) analysis. Differences between monitor systems in combinations of detector systems were compared using ANOVA and paired-samples t-test.Results
Area under curves (AUC) for the presence of linear opacities measured by ROC analysis was higher on the LCDs than CRTs without statistical significance (p = 0.082). AUC was significantly higher on the DR systems than CR systems (p = 0.006). AUC was significantly higher on the LCDs than CRTs for DR systems (p = 0.039) but not different for CR systems (p = 0.301).Conclusion
In clinical conditions, performance of the LCD monitor appears to be better for detecting interstitial lung markings when interfaced with DR systems. 相似文献20.
Martijn R. Meijerink Petrousjka van den TolAukje A.J.M. van Tilborg Jan Hein T.M. van WaesbergheSybren Meijer Cornelis van Kuijk 《European journal of radiology》2011,77(1):167-171