首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: To evaluate the correlations between prostate volumes estimated by transabdominal, transrectal, and three-dimensional US and the factors affecting the differences. MATERIALS AND METHODS: The prostate volumes of 94 consecutive patients were measured by both transabdominal and transrectal US. Next, the prostate volumes of 58 other patients was measured by both transrectal and three-dimensional US. We evaluated the degree of correlation and mean difference in each comparison. We also analyzed possible factors affecting the differences, such as the experiences of examiners in transrectal US, bladder volume, and prostate volume. RESULTS: In the comparison of transabdominal and transrectal US methods, the mean difference was 8.4 +/- 10.5 mL and correlation coefficient (r) was 0.775 (p < 0.01). The experienced examiner for the transrectal US method had the highest correlation (r = 0.967) and the significantly smallest difference (5.4 +/- 3.9 mL) compared to the other examiners (the beginner and the trained; p < 0.05). Prostate volume measured by transrectal US showed a weak correlation with the difference (r = 0.360, p < 0.05). Bladder volume did not show significant correlation with the difference (r = -0.043, p > 0.05). The comparison between the transrectal and three-dimensional US methods revealed a mean difference of 3.7 +/- 3.4 mL and the correlation coefficient was 0.924 for the experienced examiner. Furthermore, no significant difference existed between examiners (p > 0.05). Prostate volume measured by transrectal US showed a positive correlation with the difference for the beginner only (r = 0.405, p < 0.05). CONCLUSION: In the prostate volume estimation by US, experience in transrectal US is important in the correlation with transabdominal US, but not with three-dimensional US. Also, less experienced examiners' assessment of the prostate volume can be affected by prostate volume itself.  相似文献   

2.

Objective

To compare the use of conventional, real-time compound, and pulse-inversion harmonic imaging in the evaluation of breast nodules.

Materials and Methods

Fifty-two breast nodules were included in this study, conducted between May and December 2000, in which conventional, real-time compound, and pulse-inversion harmonic images were obtained in the same plane. Three radiologists, each blinded to the interpretations of the other two, evaluated the findings, characterizing the lesions and ranking the three techniques from grade 1, the worst, to grade 3, the best. Lesion conspicuity was assessed, and lesions were also characterized in terms of their margin, clarity of internal echotexture, and clarity of posterior echo pattern. The three techniques were compared using Friedman''s test, and interobserver agreement in image interpretation was assessed by means of the intraclass correlation coefficient.

Results

With regard to lesion conspicuity, margin, and internal echotexture of the nodules, real-time compound imaging was the best technique (p < 0.05); in terms of posterior echo pattern, the best was pulse-inversion harmonic imaging (p < 0.05). Real-time compound and pulse inversion harmonic imaging were better than conventional sonography in all evaluative aspects. Interobserver agreement was greater than moderate.

Conclusion

Real-time compound and pulse-inversion harmonic imaging procedures are superior to conventional sonography in terms of both lesion conspicuity and the further characterization of breast nodules. Real-time compound imaging is the best technique for evaluation of the margin and internal echotexture of nodules, while pulse-inversion harmonic imaging is very effective for the evaluation of the posterior echo patterns.  相似文献   

3.

Objective

To determine the findings of various focal hepatic lesions at contrast-enhanced gray-scale ultrasound (US) using a coded harmonic angio (CHA) technique and emphasizing lesion characterization.

Materials and Methods

The study involved 95 patients with 105 focal hepatic lesions, namely 51 hepatocellular carcinomas (HCCs), 22 metastases, 22 hemangiomas, four cases of focal nodular hyperplasia (FNH), and six nontumorous nodules. After the injection of a microbubble contrast agent (SH U 508A), gray-scale harmonic US studies using a CHA technique were performed with a combination of continuous scanning to assess the intratumoral vasculature (vascular imaging) and interval-delay scanning to determine the sequential enhancement pattern (acoustic emission imaging). Each imaging pattern was categorized and analyzed.

Results

At vascular imaging, 69% of HCCs (35/51) showed irregular branching vessels, while in 91% of metastases (20/22) a peripherally stippled pattern was observed. Intratumoral vessels were absent in 95% of hemangiomas (21/22) and all nontumorous lesions (6/6), while in 75% of FNHs (3/4) a spoke-wheel pattern was evident. At acoustic emission imaging, 71% of HCCs (36/51) showed heterogeneous enhancement and 86% (19/22) of metastases showed rim- or flame-like peripheral enhancement during the early phase, with washout occurring in all HCCs and metastases (100%, 73/73) during the late phase. In hemangiomas, enhancement was either peripheral and nodular (19/22, 86%) or persistent and homogeneous (3/22, 14%), and 75% of FNHs (3/4) became isoechoic during the late phase.

Conclusion

At contrast-enhanced gray-scale US using a CHA technique, a period of continuous scanning depicted the intratumoral vasculature, and interval-delay scanning demonstrated the sequential enhancement pattern. The characteristic findings of various focal hepatic lesions were thus determined.  相似文献   

4.
OBJECTIVE: To compare the diagnostic performances of conventional ultrasound (US) and US elastography for the differentiation of nonpalpable breast masses, and to evaluate whether elastography is helpful at reducing the number of benign biopsies, using histological analysis as a reference standard. MATERIALS AND METHODS: Conventional US and real-time elastographic images were obtained for 100 women who had been scheduled for a US-guided core biopsy of 100 nonpalpable breast masses (83 benign, 17 malignant). Two experienced radiologists unaware of the biopsy and clinical findings analyzed conventional US and elastographic images by consensus, and classified lesions based on degree of suspicion regarding the probability of malignancy. Results were evaluated by receiver operating characteristic curve analysis. In addition, the authors investigated whether a subset of lesions was categorized as suspicious by conventional US, but as benign by elastography. RESULTS: Areas under the ROC curves (Az values) were 0.901 for conventional US and 0.916 for elastography (p = 0.808). For BI-RADS category 4a lesions, 44% (22 of 50) had an elasticity score of 1 and all were found to be benign. CONCLUSION: Elastography was found to have a diagnostic performance comparable to that of conventional US for the differentiation of nonpalpable breast masses. The authors conclude that BI-RADS category 4a lesions with an elasticity score of 1 probably do not require biopsy.  相似文献   

5.

Objective

To compare phase-inversion sonography during the liver-specific phase of contrast enhancement using a microbubble contrast agent with conventional B-mode sonography for the detection of VX2 liver tumors.

Materials and Methods

Twenty-three rabbits, 18 of which had VX2 liver tumor implants, received a bolus injection of 0.6 g of Levovist (200 mg/ml). During the liver-specific phase of this agent, they were evaluated using both conventional sonography and contrast-enhanced phase-inversion harmonic imaging (CE-PIHI). Following sacrifice of the animals, pathologic analysis was performed and the reference standard thus obtained. The conspicuity, size and number of the tumors before and after contrast administration, as determined by a sonographer, were compared between the two modes and with the pathologic findings.

Results

CE-PIHI demonstrated marked hepatic parenchymal enhancement in all rabbits. For VX2 tumors detected at both conventional US and CE- PIHI, conspicuity was improved by contrast-enhanced PIHI. On examination of gross specimens, 52 VX2 tumors were identified. Conventional US correctly detected 18 of the 52 (34.6%), while PIHI detected 35 (67.3%) (p < 0.05). In particular, conventional US detected only three (8.3%) of the 36 tumors less than 10 mm in diameter, but CE-PIHI detected 19 such tumors (52.8%) (p < 0.05).

Conclusion

Compared to conventional sonography, PIHI performed during the liver-specific phase after intravenous injection of Levovist is markedly better at detecting VX2 liver tumors.  相似文献   

6.
High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments.  相似文献   

7.
Because US plays a key role in the initial evaluation of hepatic hemangiomas, knowledge of the entire spectrum of US appearances of these tumors is important. Most hemangiomas have a distinctive US appearance, and even with those with atypical appearances on conventional gray-scale US, specific diagnoses can be made using pulse-inversion harmonic US with contrast agents. In this essay, we review the spectrum of US appearances of hepatic hemangiomas on conventional gray-scale, power Doppler, and pulse-inversion harmonic US with contrast agents.  相似文献   

8.

Objective

We wanted to compare the imaging features of renal cell carcinoma (RCC) and their diagnostic accuracy on agent detection imaging (ADI) and gray-scale ultrasonography (US).

Materials and Methods

Thirty non-consecutive patients (age range; 32-80 years, mean age; 53.7 years) with 30 RCCs were examined with gray-scale US and with ADI in conjunction with using SH U 508A. We described the imaging features of the renal tumors obtained from ADI according to their enhancement pattern, the intratumoral anechoic areas and the presence of any pseudocapsule. The imaging features and diagnostic accuracy of ADI and gray-scale US were then compared.

Results

On the ADI exam, the RCCs were shown as being heterogeneous in 87% of the cases (26/30), homogeneous in 7% of the cases (2/30), and there was peripheral irregular enhancement in 7% of the cases (2/30). Intratumoral anechoic areas and pseudocapsule were seen in 87% and 77% of the RCCs on the ADI exam, whereas these features were seen in 53% and 17% of the cases on the gray-scale US, respectively. The diagnostic sensitivity, specificity, and accuracy for RCC with ADI were 97%, 93%, and 95%, respectively. However, those for RCC with using gray-scale US were 70%, 86%, and 78%, respectively. There was a significant difference for the diagnostic accuracy of RCC between ADI and gray-scale US (p < 0.05).

Conclusion

Agent detection imaging can help visualize the enhancement pattern of RCC and improve the diagnostic accuracy of this tumor by better displaying the intratumoral anechoic areas and the pseudocapsule than does the gray-scale US.  相似文献   

9.
OBJECTIVE: This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. MATERIALS AND METHODS: Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. RESULTS: The z-axis length (mean +/- standard deviation) of the beam hardening artifact was 4.5 +/- 0.8 cm in the arthroplastic knees and 3.9 +/- 2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. CONCLUSION: The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating post-arthroplasty patients.  相似文献   

10.

Objective

The aim of this study was to examine the feasibility of perfusion imaging of the brain using the Z-score and subtraction dynamic images obtained from susceptibility contrast MR images.

Materials and Methods

Five patients, each with a normal MRI, Moya-moya, a middle cerebral artery occlusion, post-trauma syndrome, and a metastatic brain tumor, were selected for a presentation. A susceptibility-contrast echo-planar image after a routine MRI was taken as the source image with a rapid manual injection of 0.1 mmol/kg of Gd-DTPA. The inflow and washout patterns were observed from the time-signal intensity curve of the serial scans using the standard program of an MRI machine. The repeated Z-score images of the peak and late phases were made using the threshold Z-score values between 1.4 and 2.0 in four to five studies of the pre-contrast, peak, and late phases. Dynamic subtraction images were produced by subtracting sequential post-contrast images from a pre-contrast image and coloring these images using a pseudocolor mapping method.

Results

In the diseases with perfusion abnormalities, the Z-score images revealed information about the degree of perfusion during the peak and late phases. However, the quality varied with the Z-score threshold and the studies selected in a group. The dynamic subtraction images were of sufficient quality with no background noise and more clearly illustrated the temporal changes in perfusion and delayed perfusion.

Conclusion

The Z-scores and dynamic subtraction images illustrated the degree of perfusion and sequential changes in the pattern of perfusion, respectively. These images can be used as a new complimentary method for observing the perfusion patterns in brain diseases.  相似文献   

11.
Kan JH  Fines BP  Funaki B 《Academic radiology》2001,8(12):1208-1214
RATIONALE AND OBJECTIVES: The purpose of this study was to assess the feasibility and accuracy of emergent hydrocolonic ultrasonography (US) performed by on-call residents in patients suspected of having appendicitis. MATERIALS AND METHODS: Thirty-one patients with a clinically equivocal diagnosis of appendicitis were prospectively evaluated with conventional US, hydrocolonic US, and appendiceal computed tomography (CT). Midlevel radiology residents performed the US examinations while they were on call. Sensitivity, specificity, and accuracy for diagnosing appendicitis were calculated for conventional and hydrocolonic US by using clinical outcome as the standard. Results of US and CT of the appendix were also correlated. Residents recorded their diagnostic confidence for conventional and hydrocolonic US. All patients were able to hold the rectally administered contrast material until completion of both hydrocolonic US and appendiceal CT. RESULTS: The sensitivity for detecting appendicitis with conventional US, hydrocolonic US, and appendiceal CT was 50%, 75%, and 100%, respectively. Specificity was 96%, 93%, and 93%, respectively. Identification of the normal and abnormal appendix improved from 13% (four of 31 patients) with conventional US to 35% (11 of 31 patients) with hydrocolonic US. The radiology residents' diagnostic confidence increased from 0.74 with conventional US to 0.83 with hydrocolonic US. CONCLUSION: Hydrocolonic US is a feasible addition to conventional US examination for patients suspected of having appendicitis. It improves sensitivity, increases radiology residents' confidence, and is well tolerated by patients.  相似文献   

12.

Objective

The purpose of this study was to compare the effectiveness of MR urography (MRU) with that of ultrasonography (US) in the evaluation of urinary tract when this failed to opacify during excretory urography (EXU).

Materials and Methods

Twelve urinary tracts in 11 patients were studied. In each case, during EXU, the urinary system failed to opacify within one hour of the injection of contrast media, and US revealed dilatation of the pelvocalyceal system. Patients underwent MRU, using a HASTE sequence with the breath-hold technique; multi-slice acquisition was then performed, and the images were reconstructed using maximal intensity projection. Each set of images was evaluated by three radiologists to determine the presence, level, and cause of urinary tract obstruction.

Results

Obstruction was present in all twelve cases, and in all of these, MRU accurately demonstrated its level. In this respect, however, US was successful in only ten. The cause of obstruction was determined by MRU in eight cases, but by US in only six. In all of these six, MRU also successfully demonstrated the cause.

Conclusion

MRU is an effective modality for evaluation of the urinary tract when this fails to opacify during EXU, and appears to be superior to US in demonstrating the level and cause of obstruction.  相似文献   

13.

Objective

To compare the efficacy of Mangafodipir trisodium (Mn-DPDP)-enhanced MR cholangiogrphy (MRC) and Gadobenate dimeglumine (Gd-BOPTA)-enhanced MRC in visualizing a non-dilated biliary system.

Materials and Methods

Eighty-eight healthy liver donor candidates underwent contrast-enhanced T1-weighted MRC. Mn-DPDP and Gd-BOPTA was used in 36 and 52 patients, respectively. Two radiologists reviewed the MR images and rated the visualization of the common duct, the right and left hepatic ducts, and the second-order branches using a 4-point scale. The contrast-to-noise ratio (CNR) of the common duct to the liver in the two groups was also compared.

Results

Mn-DPDP MRC and Gd-BOPTA MRC both showed similar visualization grades in the common duct (p = .380, Mann-Whitney U test). In the case of the proximal bile ducts, the median visualization grade was significantly higher with Gd-BOPTA MRC than with Mn-DPDP MRC (right hepatic duct: p = 0.016, left hepatic duct: p = 0.014, right secondary order branches: p = 0.006, left secondary order branches, p = 0.003). The common duct-to-liver CNR of the Gd-BOPTA MRC group was significantly higher (38.90±24.50) than that of the Mn-DPDP MRC group (24.14±17.98) (p = .003, Student''s t test).

Conclusion

Gd-BOPTA, as a biliary contrast agent, is a potential substitute for Mn-DPDP.  相似文献   

14.
We compared dynamic contrast-enhanced three-dimensional time of flight (3DTOF) magnetic resonance angiography (MRA) with two-dimensional time of flight (2DTOF) MRA with cardiac compensated fast gradient recalled echo (C-MON) and conventional angiography (CA) when it was available. C-MON re-orders the normal data acquisition to minimize ghosting artifacts generated by pulsatile flow. The initial phase of the study involved optimization of parameters and comparison C-MON with no C=MON in eight patients and volunteers. The final phase of the study involved 53 patients who were imaged with contrast-enhanced 3DTOF MRA and 2DTOF MRA with C-MON. Thirty of these patients also had CA. In the initial phase, 2DTOF MRA with C-MON was found to be equal (n = 3) or superior (n = 5) to 2DTOF without C-MON. In the final phase, the agreement among all imaging modalities varied from substantial to almost perfect (Cohen's K = .6-.83). The lowest agreement was using 2DTOF to evaluate the external iliac segments. The among suggested treatments varied from substantial to almost perfect for all imaging modalities (Cohen's K = .73–93). The diagnostic efficacies of 2DTOF with C-MON and contrast-enhanced 3DTOF were high overall, with the lowest value being a specificity of 63% for one reader in the evaluation of an external iliac segment using 2DTOF. In summary, 2DTOF with C-MON helped to eliminate artifacts due to pulsatility in the iliac arterial segments. In our experience, both dynamic constrast-enhanced 3DTOF MRA and 2DTOF MRA with C-MON performed well in the evaluation of the iliac arteries. Both studies have high interobserver agreement and high diagnostic efficacy. Contrast-enhanced 3DTOF MRA should be reserved for situations in which the iliac vessels are extremely tortuous or occluded or the external iliac segments are poorly seen.  相似文献   

15.

Objective

To assess the utility of multiphasic perfusion CT in the prediction of final infarct volume, and the relationship between lesion volume revealed by CT imaging and clinical outcome in acute ischemic stroke patients who have not undergone thrombolytic therapy.

Materials and Methods

Thirty-five patients underwent multiphasic perfusion CT within six hours of stroke onset. After baseline unenhanced helical CT scanning, contrast-enhanced CT scans were obtained 20, 34, 48, and 62 secs after the injection of 90 mL contrast medium at a rate of 3 mL/sec. CT peak and total perfusion maps were obtained from serial CT images, and the initial lesion volumes revealed by CT were compared with final infarct volumes and clinical scores.

Results

Overall, the lesion volumes seen on CT peak perfusion maps correlated most strongly with final infarct volumes (R2=0.819, p<0.001, slope of regression line=1.016), but individual data showed that they were less than final infarct volume in 31.4% of patients. In those who showed early clinical improvement (n=6), final infarct volume tended to be overestimated by CT peak perfusion mapping and only on total perfusion maps was there significant correlation between lesion volume and final infarct volume (R2=0.854, p=0.008). The lesion volumes depicted by CT maps showed moderate correlation with baseline clinical scores and clinical outcomes (R=0.445-0.706, p≤0.007).

Conclusion

CT peak perfusion maps demonstrate strong correlation between lesion volume and final infarct volume, and accurately predict final infarct volume in about two-thirds of the 35 patients. The lesion volume seen on CT maps shows moderate correlation with clinical outcome.  相似文献   

16.

Objective

This study was designed to compare three different measures of the elderly human brain; the magnetization transfer ratio (MTR) histogram, the percentage of brain parenchymal volume, and the volume of T2 hyperintense areas in terms of correlations with the study subjects'' neurocognitive performance.

Materials and Methods

Thirty-five healthy community-dwelling elderly volunteers aged 60-82 years underwent dual fast spin-echo (FSE) imaging and magnetization transfer imaging. A semi-automated technique was used to generate the MTR histogram, the brain parenchymal volume, and the T2 lesion volume. The subjects'' neurocognitive performance was assessed by using the Korean-Mini Mental State Examination (K-MMSE) and additional tests. The peak height of the MTR (PHMTR), the percentage of brain parenchymal volume (PBV), and the normalized T2 lesion volume (T2LV) were compared between the normal group (Z score on the K-MMSE ≥ -2, n=23) and the mild cognitive impairment group (Z score on the K-MMSE < -2, n=12), and these parameters were correlated with age and various neurocognitive performance scores.

Results

The PHMTR was significantly lower in the cognitively impaired subjects than the PHMTR in the normal subjects (p = 0.005). The PBV scores were lower in the cognitively impaired subjects than in the normal subjects (p = 0.02). The T2LV scores were significantly higher in the cognitively impaired subjects (p = 0.01). An inverse correlation was found between the PHMTR and T2LV (r = -0.747, p < 0.001), and also between the PBV and T2LV (r = -0.823, p < 0.001). A positive correlation was observed between the PHMTR and the PBV (r = 0.846, p < 0.001). Scores on the various neurocognitive tests were positively correlated with the PHMTR (6 of 7 items) and the PBV (5 of 7 items), and they were negatively correlated with the T2LV (5 of 7 items).

Conclusion

Our findings of a correlation among the PBV, the T2LV, and the PHMTR suggest that MTR histograms and the PBV and T2LV can be used as a reliable method and valid statistical tool, respectively, for quantifying the total lesion burden in an aging brain.  相似文献   

17.
PURPOSE: To compare the findings related to esophageal/gastric varices and congestive gastropathy on intravenous computed tomography (CT) portography (CTP) and upper gastrointestinal endoscopy (UGIE) in children with extrahepatic portal venous obstruction (EHO) presented with hematemesis. METHODS/MATERIALS: Fifty pediatric patients (age < 15 years) with EHO (initially diagnosed on abdominal ultrasound) presented with hematemesis and underwent UGIE and intravenous CTP using a helical CT scanner. Axial sections of 2 mm each were obtained with a collimation of 2 mm and a table feed of 3 mm. CTP findings on these axial sections were compared with UGIE (gold standard). RESULTS: The sensitivity of CTP for detection of esophageal varices, gastric varices, and gastropathy was 32/33 (97%), 38/40 (95%), and 30/32 (93%), respectively. CTP showed false positivity as well, which was 5/17 (29%), 2/10 (20%), and 13/17 (76%) for esophageal varices, gastric varices, and gastropathy, respectively. On follow-up UGIE, the endoscopic features appeared in 14/19 (74%) of false positive patients. Therefore, false positivity for all the parameters on CTP when compared to the initial UGIE represented the changes in vasculature before they were endoscopically manifest. CONCLUSIONS: CTP was likely to pick up changes in esophageal and gastric vasculature earlier than UGIE in children with EHO presented with hematemesis.  相似文献   

18.

Purpose

Lymph node (LN) characterization is crucial in determining the stage and treatment decisions in patient with lung cancer. Although 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) has a higher diagnostic accuracy in LN characterization than anatomical imaging, differentiating between metastatic and inflammatory LNs is still challenging because both could show high 18F-FDG uptake. The purpose of this study was to assess if the heterogeneity of the 18F-FDG uptake could help in differentiating between inflammatory and metastatic LNs in lung cancer, and to compare with other parameters.

Methods

A total of 44 patients with adenocarcinoma of the lung, who underwent preoperative 18F-FDG PET/CT without having any previous treatments and were revealed to have 18F-FDG-avid LNs, were enrolled. There were 52 pathology-proven metastatic lymph nodes in 26 subjects. The pathology-proven metastatic LNs were compared with 42 pathology-proven inflammatory/benign LNs in 18 subjects. The coefficient of variation (CV) was used to assess the heterogeneity of 18F-FDG uptake by dividing the standard deviation of standardized uptake value (SUV) by mean SUV. The volume of interest was manually drawn based on the combined CT images of 18F-FDG PET/CT (no threshold is used). Comparisons were made with the maximum standardized uptake values (SUVmax), visual assessment of 18F-FDG uptake, longest diameter, and maximum Hounsfield units (HUmax).

Results

Metastatic lymph nodes tended to have higher CVs than the inflammatory LNs. The mean CV of metastatic LNs (0.30 ± 0.08; range: 0.08–0.55) was higher than that of inflammatory LNs (0.17 + 0.06; range, 0.07–0.32; P < 0.0001). On receiver operating characteristic (ROC) curve analysis, the area under curve was 0.901, and using 0.20 as cut-off value, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 88.5 %, 76.2 %, 82.2 %, 84.3, and 83.0 % respectively. Accuracy of CV was slightly higher than SUVmax and diameter, but significantly higher than visual assessment and HUmax.

Conclusions

In patients with adenocarcinoma of the lung having no prior treatments, metastatic LNs showed more heterogeneous 18F-FDG uptake than inflammatory LNs. Measuring the CV of the SUV derived from a manual volume of interest (VOI) can be helpful in determining metastatic LN of adenocarcinoma of the lung. Including diagnostic criteria of CV into the diagnostic approach can increase the accuracy of mediastinal node status.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号