首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This review illustrates the varied appearances of benign and malignant papillary breast tumours, as identified by a breast cancer-screening programme. The commonest mammographic appearance of a papillary tumour is as a soft-tissue mass, with calcification present in less than half of cases. When calcification is present the pattern is variable, but clusters of pleomorphic calcification can occur, sometimes resembling the mammographic appearance of invasive ductal carcinoma. Ultrasonography of papillary lesions typically shows a solid, oval, intraductal mass, often associated with duct dilatation. A cystic component is also commonly seen, and lesions may appear hypervascular on colour Doppler ultrasound. Magnetic resonance imaging (MRI) has a high sensitivity, but low specificity for detecting papillary tumours, and is useful in establishing the extent and distribution of lesions in patients with multiple papillomatosis. Despite a benign histology on core biopsy, an argument exists for complete surgical excision of all papillary tumours, as a significant proportion of papillomas will contain foci of atypia or overt malignant change.  相似文献   

2.
PURPOSE: To describe the imaging and histologic features of large-core needle biopsy (LCNB) specimens of fibrous nodules. MATERIALS AND METHODS: Of 853 breast masses in which LCNB was performed, 38 (4%) revealed histologic findings of fibrous nodules. Repeat biopsy was performed in 16 lesions (surgical excision, 13 lesions; repeat LCNB, three lesions). The mammographic and ultrasonographic findings in these 16 cases, the histologic LCNB findings, and the repeat biopsy findings were retrospectively reviewed. RESULTS: Repeat biopsy findings confirmed the diagnosis of fibrous nodules in 15 of the 16 masses. In one mass, repeat LCNB findings showed a fibroadenoma. The imaging features of the fibrous nodules varied. Five nodules (33%) manifested as masses with indistinct margins; six (40%), as circumscribed masses. In four cases (27%), imaging suggested malignancy. None were calcified masses. An additional 22 masses had circumscribed or indistinct borders and were diagnosed with LCNB as fibrous nodules. None of these masses had suspicious findings, and repeat biopsy was not performed. CONCLUSION: Fibrous nodules usually manifest as masses with circumscribed or indistinct margins but can have findings suggestive of malignancy. LCNB can reveal histologic findings consistent with this diagnosis. In all masses in which repeat biopsy was performed, the diagnosis of a fibrous nodule was confirmed or another benign stromal lesion was diagnosed.  相似文献   

3.
PURPOSE: To determine the rate and causes of false-negative findings and histologic underestimates at stereotactic biopsy of nonpalpable breast lesions. MATERIALS AND METHODS: Stereotactic, 14-gauge, automated, large-core needle biopsy (LCNB) was performed in 483 consecutive nonpalpable breast lesions. Excision was advised for the 143 carcinomas, 25 atypical ductal hyperplasia (ADH) lesions, and five radial scars. Mammographic follow-up was advised for the benign lesions without a repeat biopsy. RESULTS: Of the 310 benign lesions, 259 underwent mammographic follow-up at 6-85 months (median, 55 months) without repeat biopsy, 48 underwent repeat biopsy and three were lost to follow-up. On the basis of the histologic diagnosis of carcinoma at surgical biopsy, diagnosis with LCNB was not correct (i.e., disease was underestimated at histologic examination) in 14 (58%) of 24 ADH lesions and two (40%) of five radial scars. Two (1.2%) of 161 lesions with a final diagnosis of carcinoma were benign at LCNB but malignant at repeat biopsy (i.e., false-negative findings at LCNB). Repeat biopsy was prompted by mammographic progression at 6 and 18 months after LCNB. CONCLUSION: The false-negative rate with LCNB was 1.2% in this study and 4.0% in the literature. The presence of carcinoma in ADH and radial scar lesions was often underestimated.  相似文献   

4.
Imaging-guided core needle biopsy of papillary lesions of the breast   总被引:9,自引:0,他引:9  
OBJECTIVE: Our objective was to assess the incidence of papillary lesions of the breast diagnosed at imaging-guided core needle biopsy and the need for surgical excision after a benign diagnosis. MATERIALS AND METHODS: This retrospective study included 1374 patients with consecutive suspicious breast lesions that underwent either mammography or sonographically guided large-core needle breast biopsy. Fifty-seven lesions (4%) were classified as papillary lesions. Eleven of the 57 cases were lost to follow-up (n = 6) or had not yet shown 2 years of stability (n = 5) and were excluded from this study. The remaining 46 papillary lesions constitute our study population. RESULTS: Surgical excision was performed in 17 (37%) of 46 papillary lesions. In the group of patients whose lesions were recommended for excision because carcinoma was identified at core biopsy, surgical excision revealed one false-positive and two true-positive diagnoses. In four cases, histologic diagnoses of the excisional biopsy and the core needle biopsy were discordant. One false-positive finding at core needle biopsy initially was interpreted as invasive ductal carcinoma on the basis of core needle biopsy specimens. In three false-negative findings, the initial diagnosis at core needle biopsy was upgraded after surgical excision. Two cases of papilloma with adjacent atypical ductal hyperplasia and one of atypical papilloma were upgraded to ductal carcinoma in situ after surgical excision. Imaging follow-up was performed in the remaining 29 patients. All lesions were stable or had decreased in size during the 2-year follow-up period. The negative predictive value of core needle biopsy for excluding malignancy among the papillary lesions diagnosed in our study was 93%. CONCLUSION: When the histologic diagnosis is benign, our data suggest that papillary lesions may be safely managed with imaging follow-up rather than with surgical excision. However, atypical papillary lesions or those associated with atypia require surgical excision because histologic underestimation occurs at a frequency similar to that in other atypical lesions undergoing core needle biopsy.  相似文献   

5.
OBJECTIVE: The purpose of our study was to evaluate how often a mammographic abnormality thought to be produced by the biopsy procedure was evident on the initial follow-up mammogram after percutaneous biopsy of impalpable histologically benign lesions. We compared three stereotactic percutaneous biopsy methods. CONCLUSION: A mammographic density seen well only in the projection parallel to the biopsy needle tract was evident in 2% (5/226) of the lesions for which 11-gauge directional vacuum-assisted biopsy was used, 0% (0/96) of the lesions for which 14-gauge directional vacuum-assisted biopsy was used, and 0% (0/422) of the lesions for which 14-gauge automated large-core biopsy was used. No mammographic abnormalities assessed as BI-RADS categories 3, 4, or 5 (according to the American College of Radiology's Breast Imaging Reporting and Data System) and thought to be produced by the biopsy procedure were evident after any of the biopsy methods.  相似文献   

6.
OBJECTIVE: The purpose of this prospective study was to assess the accuracy of an add-on stereotactic unit for core needle biopsy of mammographic lesions. SUBJECTS AND METHODS. Between September 1994 and February 2001, 506 stereotactic core needle biopsies of mammographic lesions in 492 patients were performed in our center on a mammography unit with add-on stereotactic equipment. Of the initial 92 patients, 80 underwent stereotactic core needle biopsy and surgical excision simultaneously. In subsequent cases, surgical biopsy was performed after core biopsy in patients who had malignant or atypical histologic results or discordance between mammographic and pathologic findings. Follow-up mammography was advised for all patients whose core biopsy results were diagnosed as benign lesions. RESULTS: Histologic results for 506 lesions undergoing stereotactic core needle biopsy were as follows: 113 (22.3%) were malignant; 369 (72.9%), benign; and 24 (4.7%), atypical. Of 113 malignant lesions identified at stereotactic core needle biopsy, 111 were confirmed as malignant, whereas two showed no evidence of malignancy at surgical excision. Of 369 lesions diagnosed as benign at stereotactic core needle biopsy, 172 (46.6%) showed no change on follow-up mammography, 114 (30.9%) were lost to follow-up, and 83 (22%) underwent surgical excision. Of 24 lesions with atypical histology, 23 had surgical follow-up, six were malignant, nine were benign, and eight were confirmed as showing atypical histology. Stereotactic core needle biopsy of the 506 lesions was complicated by five (1.0%) cases of vasovagal attack and four (0.8%) cases of bleeding. The resulting sensitivity, specificity, and positive and negative predictive values were 98.3%, 93.0%, 86.0%, and 99.2% respectively. CONCLUSION: Biopsy with an add-on unit is safe, reliable, accurate, and cost-effective with results comparable to those reported for dedicated prone biopsy devices.  相似文献   

7.
PURPOSE: To review ultrasound (US) findings in patients who have suspicious microcalcifications with low concern of malignancy (BI-RADS category 4A) on screening mammography and to evaluate helpful findings in differentiating benign and malignant lesions. MATERIALS AND METHODS: Between August 2005 and July 2006, 192 patients showed microcalcifications only, without mass or associated density, on screening mammography. Among them, we selected 82 patients who had microcalcifications with low concern of malignancy (category 4A) that were pathologically confirmed by surgical excision after wire localization (n=23) or biopsy (n=59). Breast US was performed in 37/82 cases and we analyzed the US findings for the calcification areas in these patients, evaluating the findings with benign or malignant pathological results. We correlated US findings with mammographic calcifications using mammography-guided 2D-localization for the calcifications before US examination. RESULTS: There were 12 malignant lesions (32.4%) including 3 invasive ductal carcinomas (IDC), one microinvasive ductal carcinoma (MIDC), 8 ductal carcinoma in situ (DCIS) and 25 benign lesions (67.6%) including 2 atypical ductal hyperplasias (ADH). IDC showed calcifications within heterogeneous hypoechoic parenchyma or calcifications within complex hypoechoic masses of taller-than-wide shape on US. One MIDC showed calcifications within heterogeneous hypoechoic parenchyma and six DCIS showed negative findings, or calcifications with a small nodule, or only calcifications on US. The most common positive US finding in benign lesions was cysts with calcifications. In 24/37 cases (64.8%) with negative US findings, 18 (75%) were benign lesions and 6 (25%) were DCIS. CONCLUSION: In patients with category 4A microcalcifications without associated findings on screening mammography, negative US findings had a high rate of benign results (18/24, 75%). Visible calcifications within heterogeneous hypoechoic parenchyma or mass on US increased the probability of malignancy.  相似文献   

8.
The aim of this study was to evaluate accuracy of 11 G vacuum-assisted percutaneous biopsy (VAPB) carried out on digital stereotaxic table, on breast non-palpable lesions (NPLs), non-visible by US. Prospective study on 132 consecutive NPLs (126 patients) not reliably found by US; 82% showed microcalcifications. Surgical confirmation was obtained in all malignant cases and when VAPB reported atypical lesion (ductal or lobular), radial scar or atypical papillary lesion. All patients with benign results were included in a mammographic follow-up programme. Two cases could not be dealt with due to technical difficulties. One to 26 cylinders were obtained from the remaining 130 NPLs. Sixty-four lesions were surgically confirmed. Forty-six of the 47 malignancies were correctly diagnosed. In one case of a malignant tumour, an atypical lesion was classified with VAPB. All cases of histologically verified lobular carcinoma in situ, atypical ductal or lobular hyperplasia, radial scar or atypical papillary lesion were correctly diagnosed preoperatively. The remaining lesions were benign in VAPB, and after 1 year of follow-up, no false negative has been found. Based on this short-term follow-up, absolute sensitivity was 97.9%, absolute specificity 84.3% and accuracy was 99.2%. For predicting invasion, accuracy was 89.1%. Vacuum-assisted percutaneous biopsy is a very accurate technique for NPLs which are not detectable by US. It can replace approximately 90% of DSB with no important complications, avoiding scars and providing a higher level of comfort.  相似文献   

9.
L P Harter  J S Curtis  G Ponto  P H Craig 《Radiology》1992,185(3):713-714
Early reports demonstrated the diagnostic advantage of large-core (14-gauge) biopsy over fine-needle aspiration biopsy of nonpalpable lesions of the breast without apparent significant increase in morbidity. A case of malignant seeding of the needle track after a large-core biopsy of a mucinous carcinoma of the breast is documented. The potential for increased risk of tract seeding of malignancy must be considered.  相似文献   

10.
PURPOSE: To evaluate the use of stereotactic directional vacuum-assisted biopsy (SDVAB) in diagnosing and managing papillary lesions of the breast. MATERIALS AND METHODS: The authors retrospectively reviewed the mammographic and histopathologic findings of 26 cases in which papillary lesions were diagnosed at SDVAB. In all cases, subsequent surgical excision (n = 20) or long-term imaging follow-up (n = 6) was performed and correlated with findings at SDVAB. RESULTS: SDVAB of 26 lesions yielded tissue that was classified as benign in 12, atypical in six, and malignant in eight. Of the 12 lesions that were diagnosed as histologically benign at SDVAB, six were surgically excised. Of these six lesions, five yielded benign correlative results. The sixth lesion was thought to be discordant with the imaging findings, and was surgically excised and determined to be malignant. Of the six benign lesions that were not surgically sampled for biopsy, five decreased in size and one was not seen at radiographic follow-up. Of the six lesions diagnosed as atypical at SDVAB that were surgically excised, one was benign and five were atypical. None proved to be malignant. Of the eight lesions diagnosed as malignant at SDVAB, surgical excision demonstrated ductal carcinoma in situ in all eight; two also had foci of invasive carcinoma. CONCLUSION: Benign and malignant papillary lesions of the breast can be reliably diagnosed at SDVAB when the SDVAB results correlate with the imaging findings. However, the extent of malignant papillary disease may be underestimated at SDVAB; in our study, invasive carcinoma was later discovered in 25% of patients with this diagnosis.  相似文献   

11.
Pui MH  Movson IJ 《Clinical imaging》2003,27(3):150-155
Hamartoma, lipoma and fat necrosis are benign fatty tissue lesions that may present as breast lumps. The mammographic appearance may be distinctive allowing imaging diagnosis without biopsy. The characteristic feature of hamartoma is that of a compressible mass containing radiolucent fat interchanged with dense fibrous connective tissue surrounded by a thin radioopaque pseudocapsule. Lipomas are radiolucent with well-defined thin smooth capsule. Twenty-seven percent of fat necrosis appears as discrete round or oval radiolucent oil cyst with thin capsule and egg-shell calcification.  相似文献   

12.
AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS.  相似文献   

13.
PURPOSE: To retrospectively correlate high-risk proliferative breast lesions (radial scar, atypical lobular hyperplasia, lobular carcinoma in situ and papillary lesions) diagnosed on core biopsy with the definitive histopathological diagnosis obtained after surgical excision or with the follow-up, in order to assess the role of core biopsy in such lesions. To discuss the management of the patient after a core biopsy diagnosis of high-risk proliferative breast lesion. MATERIAL AND METHODS: We evaluated 74 out of 1776 core biopsies consecutively performed on 67 patients. The histopathologic findings were as follows: 11 radial scars (RS), 3 atypical lobular hyperplasias (ALH), 3 lobular carcinomas in situ (LCIS), 57 benign papillary lesions. All patients underwent bilateral mammography, whole-breast ultrasound with a linear-array broadband transducer, and core biopsy with a 14 Gauge needle and a mean number of samples of 5 (range 4-7). Sixty-two of 67 patients, for a total of 69/74 lesions, underwent surgical biopsy despite benign histopathologic findings, mostly because of highly suspicious imaging for malignancy (BIRADS 4-5), whereas 5 patients refused surgery and have been followed up for a least 18 months and are still being followed up (2 with RS, 1 with ADH and 2 with papillary lesions). RESULTS: Among the core biopsied lesions with a diagnosis of RS (n = 11) pathology revealed one ductal carcinoma in situ (DCIS) (this case was characterized by granular microcalcifications on mammography and by a mass with irregular margins on ultrasound). Also in the group of ADH (n = 3) pathology revealed one DCIS (lesion not visible on mammography but depicted as a suspicious mass on US). In the group of LCIS (n = 3) pathologists found an invasive lobular carcinoma (ILC). Among the benign papillary lesions (n = 57) histopathologic analysis of the surgical specimen revealed 7 malignant lesions (4 papillary carcinomas and 3 DCIS), whose mammographic and ultrasound findings were indistinguishable from benign lesions. Altogether there were 10 false negative results (underestimation) out of 74 core biopsies with a diagnosis of high-risk proliferative breast lesions. CONCLUSION: The high rate of histological underestimation after core biopsy (10/74) (13.5%) demands a very careful management of patents with a core biopsy diagnosis of high-risk proliferative breast lesions, especially in the case of RS, lobular neoplasia and papillary lesions. However, the high imaging suspicion for malignancy prompts surgery. It is possible to assume that, when there is a low imaging suspicion for malignancy, when enough tissue has been sampled for pathology and no atypia is found within the lesions, surgery is not mandatory but a very careful follow-up is recommended. We must underline that there is no agreement regarding the quantity of tissue to sample. Vacuum-assisted biopsy may lead to better results, although there is as yet no proof that it can actually replace surgery in this group of lesions, since it seems only to reduce but not abolish the histological underestimation.  相似文献   

14.
US of mammographically detected clustered microcalcifications   总被引:17,自引:0,他引:17  
Moon WK  Im JG  Koh YH  Noh DY  Park IA 《Radiology》2000,217(3):849-854
PURPOSE: To determine whether ultrasonography (US) can depict breast masses associated with mammographically detected clustered microcalcifications and whether the visibility at US is different between benign and malignant lesions. MATERIALS AND METHODS: Ninety-four patients with 100 mammographically detected microcalcification clusters prospectively underwent US with a 10- or 12-MHz transducer before mammographically guided presurgical hook-wire localization. The visibility of breast masses at US was correlated with histologic and mammographic findings. RESULTS: Surgical biopsy revealed 62 benign lesions, 30 intraductal cancers, and eight invasive cancers. At US, breast masses associated with microcalcifications were seen in 45 (45%) of 100 cases. US depicted more breast masses associated with malignant (31 [82%] of 38) than with benign (14 [23%] of 62) microcalcifications (P: <.001). In malignant microcalcification clusters larger than 10 mm, US depicted associated breast masses in all 25 cases. There was no statistically significant difference in shape and distribution of calcific particles, as well as in breast composition, at mammography between US visible and invisible groups. CONCLUSION: Given a known mammographic location, US with a high-frequency transducer can depict breast masses associated with malignant microcalcifications, particularly clusters larger than 10 mm. US can be used to visualize large clusters of microcalcifications that have a very high suspicion of malignancy.  相似文献   

15.
The authors have reviewed 308 localisation biopsies performed on nonpalpable breast lesions between 1986 and 1990. The initiating mammogram, specimen radiograph, radiologists' reports and histology reports have been analysed with respect to the nature of the mammographic lesion, patient age, breast parenchymal pattern and histologic diagnosis. The overall malignant biopsy rate was 28%. Malignancy was found in 67% of biopsies for architectural distortion, 27% for calcification and 25% for a mass lesion. Masses if malignant proved to have an invasive component in the majority of cases (29/33). Calcification if malignant was more often in situ carcinoma (25/44). 29% of malignant biopsies were in women under the age of 50 and approximately half of these had an invasive component. The histologic nature of benign lesions is presented with identification of those with proliferative breast disease. The results are compared with those of other recently published series. Implications are discussed for the management of minimally suspicious lesions and for screening mammography.  相似文献   

16.
目的 探讨MRI导引下肺穿刺活检术的可行性、准确性及其临床应用价值.方法 应用配备iPath 200光学追踪系统的低场开放式MR仪,对137例肺内结节或肿物患者行穿刺活检术,其中肺内孤立性结节或肿物103例,肺内多发病灶34例;病灶最大径≥3.5 cm的57例、1.5~3.4 cm的71例、≤1.4 cm的9例.结果 病灶最大径≥3.5 cm组、1.5~3.4 cm组、≤1.4 cm组及总的穿刺成功率分别为100.0%(57/57)、98.6%(70/71)、77.8%(7/9)、97.8%(134/137);穿刺组织病理检查诊断恶性肿瘤98例,良性39例;MRI导引肺穿刺活检的敏感度为94.2%(98/104),特异度为100.0%(33/33),准确性为95.6%(131/137),阳性预测值为100.0%(98/98),阴性预测值为84.6%(33/39).结论 开放式MRI导引肺穿刺活检术具有较高的安全性、准确性和有效性,值得在临床进一步推广和应用.  相似文献   

17.
Proliferative breast diseases include a group of lesions which occupy an intermediate position between benign and malignant lesions and are extremely likely to develop into carcinomas. The authors studied 81 patients who had been surgically biopsied on the basis of mammographic and/or US findings. In 33/81 (40.7%) of them proliferative lesions were diagnosed at histology. Mammography was able to identify 18/33 lesions (54.5%) versus US 26/33 (81.8%). On the basis of these findings, a group of patients at risk for cancer could be identified. As a matter of fact, proliferative lesions, especially those presenting with atypical hyperplasia, are associated with a higher risk of developing into carcinomas than those presenting with typical features. For these patients, the authors suggest more frequent clinical and instrumental screening.  相似文献   

18.
Simon JR  Kalbhen CL  Cooper RA  Flisak ME 《Radiology》2000,215(3):694-697
PURPOSE: To determine the accuracy and complications of vacuum-assisted core breast biopsy performed with ultrasonographic (US) guidance. MATERIALS AND METHODS: US-guided, vacuum-assisted breast biopsy with an 11-gauge device was performed in 71 lesions in 67 consecutive women (age range, 23-82 years; mean age, 52.9 years). Vacuum-assisted core biopsy findings were compared with excisional biopsy, mammographic follow-up, and clinical follow-up findings (follow-up, 1-19 months; mean, 9.2 months). Procedural complications and treatment were noted. RESULTS: Of 71 lesions, 18 (25%) were diagnosed as malignant at core biopsy; one (1%), as premalignant; 30 (42%), as specific benign; and 22 (31%), as nonspecific benign. Of 18 malignant diagnoses, one (6%) was benign at excision. The premalignant specimen was benign at excision. Of 52 benign findings, 51 (98%) were proved benign at excision, mammographic follow-up, or clinical follow-up. One benign finding was carcinoma at excision. In this case, the specimen did not include the carcinoma because of a technical problem recognized at the time of the percutaneous procedure. Five (7%) of 71 biopsies resulted in bleeding beyond 10 minutes. One (1%) patient experienced a vasovagal response. CONCLUSION: According to these data, US-guided vacuum-assisted core breast biopsy is accurate. There may be a slightly higher risk of bleeding, which may be related to the lack of breast compression during the procedure, when compared with biopsy performed with stereotactic guidance.  相似文献   

19.
AIM: Various modalities are used as an adjunct to mammography for differentiation of potentially suspicious breast lesions. Electrical impedance scanning (EIS) is a new technique based upon the principle that cancer cells exhibit altered local dielectric properties and thus show measurably higher conductivity values. The accuracy of differentiation of benign and malignant breast lesions was evaluated to determine whether EIS duplicates or supplements the results obtainable from ultrasound (US) or magnetic resonance imaging (MRI). MATERIALS AND METHODS: One hundred mammographically suspicious lesions were examined using US, MRI and EIS. Definitive histology was acquired through either lesion biopsy or surgical excision. RESULTS: Fifty of 62 malignant lesions were correctly identified using EIS (81% overall sensitivity), 24/38 benign lesions were correctly identified as benign (63% specificity). Negative predictive value and positive predictive value of 67 and 78% were observed, respectively. kappa-factor evaluation revealed a value of 0.82 between MRI and EIS and 0.62 between US and EIS. CONCLUSIONS: EIS may be a valuable adjunct for differentiation of suspicious mammographic lesions. Based upon the calculated kappa-factor, EIS results supplement US examinations. Artifacts (superficial skin lesions, poor contact, air bubbles) currently result in the high false-positive rate of EIS.  相似文献   

20.
Purpose: To assess the diagnostic value of ultrasound (US)-guided 14 G core needle breast biopsy in non-palpable suspicious breast lesions.

Material and Methods: From August 1997 to April 2001, 198 patients with 204 suspicious non-palpable breast lesions underwent US-guided large core needle biopsy. Biopsies were performed with a free-hand technique using US equipment with a 7.5 MHz linear-array transducer; a minimum of three cores were obtained from each lesion. Pathological findings in US-guided core biopsy were correlated to findings in subsequent surgery or long-term (more than 2 years) imaging follow-up.

Results: Among the 204 non-palpable breast lesions for which histopathological findings were obtained by US-guided core biopsy, 118 were malignant (114 carcinoma, 2 metastasis, 1 lymphoma, and 1 malignant phyllodes tumor) and 86 were benign (4 carcinoma and 82 benign lesions confirmed at surgery or after at least 2 years of follow-up). Sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy in our series were 97%, 100%, 100%, and 95%, respectively. Diagnostic yield with 1, 2, 3, and 4 specimens per lesion was 73.5%, 88%, 94%, and 97.5%, respectively.

Conclusion: US-guided core needle biopsy is a sensitive percutaneous biopsy method for diagnosing non-palpable breast lesions. To achieve a high diagnostic yield, a minimum number of three cores per lesion is advisable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号