首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
A bstract A cylindrical valve was designed to prevent regurgitation of the semilunar valve. The valve is made of a sheet of polytetrafluoroethylene (PTFE) or porcine pericardium, and has three cusps and three commissures. The diameter of the valve is equal to the height of the cusps. We have used these valves in pulmonary stenosis after Jatene's operation and total correction of tetralogy of Fallot, and for truncal valve regurgitation. Regurgitation was trivial on color Doppler echocardiography in all cases. Advantages in comparison with the implantation of commercially available artificial valves include the ability to insert a larger size and no compression of the valve ring when closing the sternum. Outflow tract obstruction does not occur even when the valve is implanted in a small infant. In the present report, we describe this simple technique.  相似文献   

2.
Although the Ross procedure is a well-established approach to aortic valve disease in pediatric patients and young adults, there still is no ideal method of right ventricular outflow tract (RVOT) reconstruction, especially in children. To achieve improved RVOT reconstruction with long-term valve function and growth potential, we have developed a hybrid valve which combines the autologous aortic valve and expanded polytetrafluoroethylene (ePTFE) valves. The posterior wall of RVOT was reconstructed using the autologous aortic wall with a noncoronary cusp, and the anterior wall was reconstructed using a patch made of bovine pericardium or ePTFE with bicuspid ePTFE valves. We implanted hybrid valves in 14 patients (age 5-18 years). During the follow-up period (2.4-8.8 years), there were no mortalities or morbidities, and no patients required reoperation. Echocardiography showed no significant stenosis and regurgitation, and preserved valve motion in all patients. The z-value of the diameters of the pulmonary annulus in early and late follow-up was -1.4 and -1.8, respectively, the difference not being significant. Creation of a hybrid valve was associated with excellent mid- to long-term results. Given its theoretical growth potential, we speculate that this valve could be a good choice for RVOT reconstruction in the Ross procedure, especially for young children.  相似文献   

3.
BACKGROUND: Surgical repair of obstructive lesions of the right ventricular outflow tract (RVOT) commonly creates pulmonary valve incompetence, which continues to stimulate research for the optimal materials and surgical techniques to reconstruct RVOT. In this study, we present the early results with simultaneous enlargement of the pulmonary annulus and the pulmonary cusp with a transannular patch of autologous pericardium in RVOT reconstruction. PATIENTS AND METHODS: From January 2003 to December 2005, the surgical technique of simultaneous enlargement of the pulmonary annulus and the pulmonary cusp was used in 32 patients who had complex congenital heart anomalies with pulmonary artery hypoplasia. The functional status of the patients was followed up in the cardiologic clinic of our institute. The motion of the newly constructed valve and the degree of pulmonary insufficiency were evaluated by echocardiography before discharge and at 2-6 months, 12 months, and 36 months postoperatively. RESULTS: Early death occurred in one patient (3.1%). Postoperative complications occurred in six patients but they recovered uneventfully. During the follow-up, 28 of 31 operative survivors were in New York Heart Association functional class I without medication and the other three were in class II. Seventeen patients had no or trivial pulmonary regurgitation; mild regurgitation was present in 12 patients, and moderate regurgitation was seen in 2 patients. None of these patients needed reoperation and echocardiography showed good motion of the reconstructed valve. CONCLUSIONS: The surgical technique of simultaneous enlargement of the pulmonary annulus and the pulmonary cusp with a transannular patch of autologous pericardium is a safe, reliable, and effective way for RVOT reconstruction. Satisfactory early results have been achieved; however, long-term follow-up is necessary to determine the true value of this technique.  相似文献   

4.
A new operation for ventricular septal defect with aortic incompetence   总被引:2,自引:0,他引:2  
Two boys, 10 years of age, with ventricular septal defect and severe aortic insufficiency were treated using a new method. An autograft of anterior pulmonary artery wall and the adjacent leaflet and subpulmonary muscle was excised. The excised pulmonary artery segment was used to replace the prolapsed right coronary cusp, and the autograft muscle was used to close the ventricular septal defect. The right ventricular outflow tract and pulmonary valve were repaired using an autologous pericardial patch with an autologous single cusp. The results in both cases were satisfactory.  相似文献   

5.
BACKGROUND: Severe mitral regurgitation associated with complex mitral valve disease often precludes successful surgical repair. The feasibility and the results of valvuloplasty with glutaraldehyde-treated autologous pericardium remain largely unknown. METHODS: The cases of 63 patients who underwent operation within an 11-year period were studied. A pretreated autologous pericardial patch was used for leaflet extension plasty, for paracommissural plasty, as a substitute for part of the leaflet, and for reimplantation of ruptured papillary muscles to eliminate severe mitral regurgitation. Patients with a severely calcified annulus after en bloc decalcification had straddling endoventricular pericardial patch annuloplasty for reconstruction of the affected atrioventricular groove. Chordal replacement with a strip of pericardium was chosen if no suitable chordae were available. Pericardium-reinforced suture annuloplasty was used in patients with acute endocarditis resistant to medical therapy. Associated valvuloplasty procedures with Carpentier techniques were also employed. RESULTS: There were no operative deaths in this series. At a mean follow-up of 61.1 months (range, 4 to 132 months), mitral regurgitation was absent or trivial in 92.1% of patients by echocardiography. Freedom from reoperation was 95.2% at 1 year and 5 years. Thromboembolic events have not been detected. Thirty percent of patients returned to sinus rhythm. Two patients required valve replacement. CONCLUSIONS: Our beneficial results indicate that glutaraldehyde-treated autologous pericardium is suitable for valvuloplasty. It provides durable and predictable repair of valves that might otherwise need to be replaced because of the complex mitral valve disease. The technique is reliable, allows further efficacious repair possibilities, and improves postoperative outcomes. Whether it can prevent late deterioration and calcification requires more investigation.  相似文献   

6.
BACKGROUND: The encouraging results of valve repair in the atrioventricular valves have influenced a decision about aortic valve (AV) reconstruction. We report our experience with pericardial cusp extension to repair rheumatic AV disease. METHODS: From 1993 to 1998, 46 patients (25 women, 21 men) with a mean age of 31.5 +/- 12.2 years (range, 15 to 58 years) underwent AV repair. Twenty-two (47.8%) patients had moderate and 24 (52.2%) had severe aortic insufficiency (AI). Severe cusp retraction was repaired with glutaraldehyde-treated autologous pericardium. Twenty-one patients had more than one maneuver (mean, 1.8) to attain competence besides augmentation, which consisted of the release of stenotic commissures (in 11 cases), thinning of the AV cusps (in 10 cases), and resuspension of the cusps (in 17 cases). Simultaneous mitral valve repair was performed on 17 patients. Eight patients received triple valve reconstruction. RESULTS: There was no early mortality. Thirty patients no longer had AI with any significant transvalvular gradients. Five patients were followed with mild residual AI, and 2 patients with moderate AI not requiring reoperation. Nine patients developing severe AI required AV replacement with a reoperation rate 19.6% (4.26%/patient-year). The mean interval between repair and reoperation was 28.2 +/- 18.3 months (range, 3 to 58 months). The mean observation time was 4.6 +/- 3 years (211.6 patient-years). Late mortality rate was 2.2% with 1 patient. The significant negative predictors of aortic reoperation determined by univariate analysis were preoperative New York Heart Association class (p = 0.002) and postoperative severe AI (p < 0.001). Cox hazard studies identified that all risk factors were insignificant for aortic reoperation. The actuarial rate of freedom from aortic reoperation was 76.1% +/- 7% at 7.5 years. CONCLUSIONS: Although AV repair by extension with pericardium is worth considering with an acceptable solution to achieve a good geometry from unequal cusps, especially in young rheumatic patients for preservation of the native AV, the patients should be followed periodically for reoperation risk.  相似文献   

7.
Preliminary experimental studies in our laboratory have shown that autologous pericardium treated with glutaraldehyde prevents late deterioration and calcification of the tissue. For this reason, glutaraldehyde-treated autologous pericardium has been used in a series of 64 patients who underwent operations for leaflet extension of the mitral valve between 1980 and 1989. Ages ranged from 2.5 to 60 years (mean 19 +/- 15). The causes of mitral valve insufficiency were rheumatic fever (69%), bacterial endocarditis (17%), congenital (8%), endomyocardial fibrosis (4.5%), and trauma (1.5%). The autologous tissue was fixed in a 0.62% glutaraldehyde solution for 15 minutes and rinsed in saline for an additional 15 minutes. Patching techniques varied depending on the site and the extent of the lesion. Associated mitral valve repair techniques (Carpentier's techniques) were mandatory in all patients. The period of follow-up extended from 6 months to 9 years (mean 3.1 +/- 2.5 years). There were no operative deaths in this series, and there was one late death (2%). In the six patients (12%) who underwent reoperation, there has been no case of calcification of the pericardial patch. Postoperative mitral valve function was assessed by bidimensional color Doppler echocardiographic techniques. Mitral valve insufficiency was trivial or absent in 80% of the patients. This experience permits us to conclude that leaflet extension is a simple and safe technique in valve reconstruction, allowing repair of mitral valves that otherwise would need to be replaced. It permits use of an adult-size prosthetic ring in children. Glutaraldehyde-treated autologous pericardium is the material of choice for this type of repair.  相似文献   

8.
Opening characteristics of three-cusp tissue heart valves   总被引:3,自引:2,他引:1       下载免费PDF全文
Since April 1969, frame-mounted three-cusp fascia lata and pericardial valves have been used in over 200 patients for heart valve replacement. Six autologous fascia lata valves have been removed from the mitral position because of regurgitation produced by shrinkage of one or two cusps. To elucidate the cause and mechanism of graft failure the opening characteristics of fascia lata and Silastic valves were studied in a steady state flow rig.  相似文献   

9.
Experimental as well as clinical data support the finding of using the pulmonary valve as a systemic semilunar valve. From January 1990 to December 1992, 89 patients received pulmonary cryopreserved allografts as aortic valve replacement. Sixteen subjects suffering from native or prosthetic valve endocarditis were included. Age ranged from 10 to 74 years. Sixty-five patients received isolated aortic valve replacement and 24 patients required additional surgical measures, such as coronary artery bypass graft, mitral valve reconstruction, replacement of the ascending aorta, supravalvular patch aortoplasty, ventricular septal defect closure, or myectomy. All operations were performed with normothermic bypass and cold cardioplegic arrest. Follow-up is maintained by visits to the outpatient clinic and echocardiographic assessment of the valve status every 3 months during the first year and every 6 months thereafter. There were four early and three late deaths. Four valves had to be removed: one intraoperatively and three 2, 4, and 24 months postoperatively. Echocardiographic assessment proved that gradients across the valve were low or absent. The majority of patients showed trivial or no aortic regurgitation during follow-up. No thromboem-bolic events have been observed and no new endocarditis occurred. Thus, event-free survival at 3 years is 87%. The results with pulmonary allografts have shown to be comparable to aortic allografts. Even in patients with acute native or prosthetic valve endocarditis, the use of cryopreserved pulmonary allografts has shown no adverse effects. We continue to implant cryopreserved pulmonary allografts In the aortic position. The long-term function of the valve, however, must be established, making continued evaluation of postoperative patients mandatory. (J Card Surg 1994;9:43–49)  相似文献   

10.
Abstract   A neonate with L-transposition of the great arteries with ventricular septal defect underwent complete repair using fresh autologous pericardium to close the ventricular septal defect as well as to reconstruct the neo pulmonary artery sinuses. Four months later, the child came back with right ventricular inflow obstruction related to aneurysmal pericardial patch, severe tricuspid regurgitation, and severe supra-valvular pulmonic stenosis. At reoperation, there was a redundant, aneurysmal pericardial patch densely adherent to the septal and posterior leaflets of the tricuspid valve, which was damaged. The pericardial patch was replaced, the pulmonary artery enlarged, and tricuspid valve repaired. Postoperative course was uneventful, but residual moderate tricuspid regurgitation required intensive medical treatment.  相似文献   

11.
BACKGROUND: Valvuloplasty has significant advantages over valve replacement for mitral regurgitation, but the presence of severe calcification of the mitral valve apparatus has been thought to preclude successful valve reconstruction in general. The purpose of this report is to assess the results of valvuloplasty in patients with severe mitral regurgitation having extensive calcification extending from the mitral annulus to underlying myocardium and parts of the papillary muscles. METHODS: Thirty-seven adult patients with severe mitral regurgitation and calcification were operated on between April 1990 and January 1998. Twenty-six patients had degenerative disease, 4 had acute bacterial endocarditis, 6 had postrheumatic fever, and 1 patient had Marfan's disease. The valve repair comprised of en bloc decalcification with extensive leaflet debridement and reconstruction of the annulus. Autologous pericardium was used in patch-extended endocardial annuloplasty or leaflet repair. Valve competence was retained after correction of regurgitation by sliding atrioplasty, rotation paracommissural sliding plasty, cusp remodeling, or chordal repair. All patients required a prosthetic annuloplasty. RESULTS: Follow-up echocardiography at 47 months (range, 3 to 92 months) showed no or only trivial mitral regurgitation in 33 patients; 3 had grade I-II mitral regurgitation and 1 required valve replacement after 3 months. Freedom of reoperation at 1 and 5 years was 94.6%. At last examination, 33 patients were in New York Heart Association functional class I and 3 in class I-II; there has been no mortality and no thromboembolic events. CONCLUSIONS: Valvuloplasty can be safely and successfully carried out in patients suffering from regurgitation associated with severe calcification of the mitral apparatus. With encouraging beneficial midterm results, we suggest patients with calcified valves should not be excluded from mitral repair.  相似文献   

12.
Infective endocarditis (IE) is a serious condition leading to heart failure, persistent sepsis. The management of IE involving valve is mainly excision of the infected valve and replacement with a heart valve; which are also at the risk of prosthetic valve endocarditis. Hence repair of the valve with autologous pericardium is much more physiological. We had a 20-year-old male presented with features of heart failure and high-grade fever not responding to optimum medical management. Two-dimensional echocardiogram revealed vegetation on pulmonary valve cusps with the erosion of the left and right cusps. Neo cusps with autologous pericardium offered good hemodynamics with trivial regurgitation. The patient is doing well with normal pulmonary valve function 3 months after surgery. This technique is reliable, economic, and easily reproducible.  相似文献   

13.
OBJECTIVE: Aortic valve cusp extension and free-hand aortic valve replacement with autologous pericardium has been described. The long-term results were shown to be comparable with commercially available aortic bioprostheses. Nevertheless the relatively demanding surgical technique could not find wide acceptance. We developed a new design of a molded aortic valve, fashioned from autologous pericardium, treated briefly with glutaraldehyde, and simplified the implantation technique using single point attached commissures (SPAC). METHODS: Molded autologous valve prostheses were implanted in the subcoronary aortic position in 10 sheep with the commissures connected to the aortic wall at three single commissural points (SPAC). The prosthesis mean size was 21.6+/-1.3 mm and the construction time (excluding 10 min glutaraldehyde treatment) was 6.2+/-1.2 min. Cardiopulmonary bypass and cross-clamp time was 111.1+/-12.4 min and 75.0+/-16.3 min, respectively. Six sheep were euthanized after 201.2+/-10.3 days (6 months) and four sheep were euthanized after 330.8+/-6.5 days (11 months) postoperatively. RESULTS: In all sheep, the valve was immediately competent. At sacrifice, SPAC has proven to be well anchored to the aortic wall and the pericardial valve to be pliable in all cases. The maximum transvalvular gradient after cardiopulmonary bypass and at sacrifice was 3.7+/-2.2 mmHg and 10.6+/-5.2 mmHg, respectively. CONCLUSIONS: This new truly stentless molded autologous aortic valve with simplified implantation technique (SPAC) makes a reliable implantation in a standard timeframe possible. The simplicity of construction, low cost and absent need for anticoagulation of this molded autologous aortic bioprosthesis offers an attractive alternative and not only for patients in the developing world.  相似文献   

14.
BackgroundWe aim to identify the incidence and timing of dysfunction and failure of stented bioprosthetic valves in the pulmonary position in congenital heart disease patients.MethodsA total of 482 congenital heart disease patients underwent 484 stented bioprosthetic pulmonary valve implantations between 2008 and 2018. There were 164 porcine valves (Porcine) and 320 bovine pericardial valves (Pericardial) implanted. Primary endpoints were survival, valve dysfunction, and valve failure.ResultsPericardial valves were implanted in older patients (22.0, interquartile range [IQR] 14-33 vs 16.0, IQR 11-23 years, P < 0.001). Five-year survival (96.7% vs 97.9%) for the Pericardial and Porcine groups, respectively, were similar, P > 0.05. Forty-six (34%) Porcine and 75 (27%) Pericardial group patients met criteria for valve dysfunction at a median echocardiographic follow-up time of 7.43 years (IQR 4.1-9.5 years) and 3.26 years (IQR 1.7-4.7 years), respectively. More Pericardial group patients suffered from at least mild late PR while late median peak gradient was higher in the Porcine group, P < .001 for both. Risk factors for valve dysfunction included decreasing patient age for the entire cohort (hazard ratio [HR] 1.02, 95% confidence interval [CI] 1.00-1.04, P = .015) and lack of anticoagulation at discharge for the Porcine group (HR 3.06, 95% CI 1.03-9.10, P = .044) but not the Pericardial group. Five-year cumulative incidence of dysfunction was 39% for the Pericardial group and 17% for the Porcine group.ConclusionsPorcine stented and bovine pericardial stented valves can be implanted in the pulmonary position in all age groups safely. However, despite similar rates of valve failure, bovine pericardial stented valves have a higher incidence of valve dysfunction at mid-term follow-up.  相似文献   

15.
OBJECTIVE: Aortic regurgitation after balloon dilation of congenital aortic stenosis may be treated with valve repair as an alternative to replacement. METHODS: Charts and echocardiograms of all patients undergoing aortic valve operations after balloon dilation of congenital aortic stenosis at our institution between January 1988 and December 1999 were reviewed. RESULTS: Twenty-one patients underwent valvuloplasty for predominant aortic regurgitation 9 months to 15 years (mean, 6.1 years) after balloon dilation. The mean +/- SD age at the time of the operation was 11 +/- 7 years. Aortic regurgitation was caused by a combination of commissural avulsion (10), cusp dehiscence with retraction (9), cusp tear (5), central incompetence (2), perforated cusp (1), or cusp adhesion to the aortic wall (1). Repair techniques included commissural reconstruction with a pericardial patch (8), pericardial patch cusp augmentation (6), primary suture repair (6), raphae release and debridement (4), commissurotomy (4), commissural resuspension with sutures (3), and cusp release (1). There were no deaths. At a mean follow-up of 30.1 months (range, 9 months-8 years), all patients were asymptomatic, and the grade of aortic regurgitation had been significantly reduced (P <.001). Left ventricular end-diastolic dimension z scores and proximal regurgitant jet/aortic anulus diameter ratios were significantly reduced (P <.001) and remained so over time. Freedom from reoperation for late failure was 100%, and overall freedom from reintervention was 80% at 3 years. CONCLUSION: Aortic valve repair for balloon-induced aortic regurgitation is reproducible and durable at medium-term follow-up.  相似文献   

16.
A 68-year-old woman was admitted with congestive heart failure and septic shock associated with suspected mitral valve acute infective endocarditis. Echocardiography revealed vegetations attached to both mitral leaflets, prolapse of the posterior mitral leaflet and severe mitral regurgitation. Emergent surgery was performed. The anterior mitral leaflet displayed multiple vegetations. The entire anterior leaflet of mitral valve was replaced with pericardium. The posterior mitral leaflet of the middle scallop was prolapsed with an attached vegetation. Quadrangular resection was performed. A commissural reconstruction by sliding commissuroplasty for a prolapse of both anterior and posterior leaflets in the paracommissural area and autologous pericardial mitral annuloplasty was performed. Mitral regurgitation disappeared postoperatively, and the patient is now doing well as of 5 years postoperatively.  相似文献   

17.
BACKGROUND AND AIM OF THE STUDY: Endocarditis with aortic root abscess is one of the most complicated surgical problems. METHODS: An 8-year-old girl presented with dyspnea, high fever, and fatigue. She had stenotic bicuspid aortic valve with endocarditis and aortic root abscess. Ross procedure was performed with fresh autologous pericardial tube and pericardial monocusp valve. Right internal mammary artery to right coronary artery bypass was also done due to destroyed right coronary artery ostium. RESULTS: Four years after the operation she is in excellent clinical condition without medications. Echocardiography reveals mild autograft regurgitation and mildly stenotic right ventricular outflow tract. CONCLUSIONS: If homografts are not available, total reconstruction of RVOT with autologous fresh pericardium may offer reasonable early and mid-term results especially when active endocarditis and aortic root abscess is involved.  相似文献   

18.
J. Borrie  N. R. Redshaw 《Thorax》1973,28(1):102-106
In sheep, stented pulmonary semilunar valves have been allografted as tricuspid valve substitutes and their biological behaviour has been followed postoperatively. Whereas there was initial pleasing function with normal cusp competence, by day 102 the cusps had retracted to partial incompetence. This process of valve decline was accentuated by day 150, and by day 241 was complete. Histological studies at day 150 showed cusp foreshortening, with scant nuclei and collagen looser than normal. These findings suggested that the mechanism causing the valve decline was a host to foreign body reaction rather than the usual histological pattern of graft rejection.  相似文献   

19.
Aneurysm of both the pulmonary trunk and the ascending aorta concomitant with bilateral bicuspid valves is very rare. The reason for the formation of aneurysm with bicuspid semilunar valve is still inconclusive. Surgical repair was performed successfully (ie, aortic valve replacement, graft replacement for the ascending aorta, and plication of the pulmonary artery). Pathology of the pulmonary artery wall did not demonstrate cystic medial necrosis. The hemodynamic turbulence by the bilateral bicuspid valve may cause the formation of aneurysms even at low pressure. This case demonstrates an explanation for aneurysm with the bicuspid valve.  相似文献   

20.
Monro, J. L., Gavin, J. B., and Barratt-Boyes, B. G. (1974).Thorax, 29, 323-328. A comparison of antibiotic-sterilized, stent-mounted pulmonary and aortic valve allografts in the mitral region of dogs. The mitral valves of 40 dogs were replaced with antibiotic-sterilized, stent-mounted semilunar valve allografts. Twenty grafts were pulmonary valves and 20 were aortic valves. Six dogs in each group died from causes related to the operation. All remaining dogs with pulmonary valve grafts died of causes related to the allograft itself (vegetative endocarditis (5), peripheral leak (1), cusp rupture (4), cusp shrinkage (4)). In the aortic valve group there were seven deaths from allograft endocarditis and one from a peripheral leak, but six dogs had competent allografts when sacrificed up to 12 months after surgery. It is concluded that the inherent strength and bulk of the aortic valve cusps make this valve a more suitable mitral valve replacement than the more delicate pulmonary valves.  相似文献   