首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND AND PURPOSE: Several angiographic features of brain arteriovenous malformations (BAVMs) have been associated with an increased risk of hemorrhage. However, interpretation of these features may not be consistent between observers. We conducted a study to determine inter- and intraobserver agreement of various angioarchitectural characteristics of BAVM. MATERIALS AND METHODS: Two experienced interventional neuroradiologists independently reviewed pre- and post-endovascular treatment angiograms from 50 consecutive patients. Axial CT and/or MR images before treatment were included. We collected the following data: Spetzler-Martin grades, number of involved arterial territories, associated aneurysms by location (circle of Willis, feeding artery, intranidal, and venous), and nidus reduction after endovascular treatment (<33%, 33%-66%, and >66%). The reviewers were compared with each other, and 1 was compared with himself after a 3-month interval. Measures of agreement were performed by using the kappa statistic (kappa) for nominal data and the weighted kappa for ordinal data. RESULTS: Inter- and intraobserver agreement were higher for assessment of the Spetzler-Martin grade (weighted kappa = 0.70/0.75) and nidus size reduction after endovascular treatment (kappa = 0.74/0.77). Inter- and intraobserver agreement were inferior for findings concerning feeding artery aneurysms (kappa = 0.19/0.36), intranidal aneurysms (kappa = 0.34/0.35), and venous aneurysms (kappa = 0.50/0.67). CONCLUSION: Angiographic characteristics of BAVMs considered as risk factors for hemorrhage, such as aneurysms, are not reliably detected on global angiograms between different observers. In contrast, the Spetzler-Martin grading system and angiographic results of endovascular treatment can be used with high observer agreement.  相似文献   

2.
PURPOSE: The thoracic aorta is an important site of atherosclerotic disease in patients with homozygous familial hypercholesterolemia (HFH). Thoracic aortic atherosclerosis in patients with HFH was assessed with contrast-enhanced MR angiograms using exoscopic and endoscopic virtual angioscopy reconstructions and maximum intensity projections (MIPs). METHOD: Contrast-enhanced MR angiograms of the thoracic aorta of 15 patients with HFH and 8 normal volunteers were obtained. Perspective surface reconstructions of the MR angiograms including virtual angioscopy views were evaluated by three radiologists blinded to the diagnosis. RESULTS: Thoracic wall irregularity was depicted on 8 of 15 (53%) patient scans and only 1 of 8 (13%) normal subject scans using surface reconstructions. Wall irregularity scores of patients with HFH were significantly increased compared with controls (2.0 +/- 0.9 vs. 1.0 +/- 0.6; p = 0.008). There was excellent interobserver agreement (weighted kappa = 0.82 +/- 0.12). Virtual endoscopy views added diagnostic confidence compared with exoscopic surface renderings alone. MIP reconstructions were unable to depict wall irregularity. CONCLUSION: MR angiography with virtual angioscopy of the thoracic aorta depicts nonstenotic wall irregularity of thoracic aortic atherosclerosis in patients with HFH. This may be important for assessing disease progression and response to treatment and may be generalizable to routine (non-HFH) atherosclerosis.  相似文献   

3.

Aim

To assess, whether unenhanced balanced steady-state-free precession sequences provide axial thoracic aortic measurements comparable to contrast enhanced magnetic resonance angiography with good intra- and interobserver agreement.

Materials and methods

Enhanced and unenhanced sequences of the thoracic aorta in 23 consecutive patients were evaluated. Axial thoracic aortic diameters were measured at predefined levels by two independent readers. Pearson's correlation coefficient and Bland–Altman analysis were used to compare enhanced and unenhanced sequences. t-Test was used to determine possible significant differences between the measurements obtained by enhanced and unenhanced sequences. A p-value of less than .05 indicated statistical significance. Intraclass correlation coefficient and Bland–Altman were used for inter- and intraobserver correlation and agreement.

Results

There was no significant difference in diameter measurements between enhanced and unenhanced sequences (ascending aorta, p = 0.98; descending aorta, p = 0.52). Bland–Altman revealed good agreement between enhanced and unenhanced sequences for ascending (mean bias, −0.01 cm; with 95% limits of agreement, ±0.30 cm) and descending aortic diameters (mean bias, 0.05 cm; with 95% limits of agreement, ±0.30 cm). Inter- and intraobserver agreement (mean bias, less than ±0.15; with 95% limits of agreement, less than ±0.42 cm for all measurements) as well as correlation (r > 0.8 for all measurements) were excellent.

Conclusion

Unenhanced balanced steady-state-free precession sequences enable rapid and accurate determination of axial thoracic aortic diameters with excellent inter- and intraobserver agreement, but without the risk of contrast media associated side-effects.  相似文献   

4.
OBJECTIVE: Preoperative MRI of fistula in ano is becoming more common. This prospective study aimed to determine if a significant difference occurred in interpretation between one expert and one novice observer and to assess inter- and intraobserver agreement after both observers underwent a period of directed education. SUBJECTS AND METHODS. An outcome-derived reference standard was defined in 100 patients with suspected fistula in ano via a combination of preoperative MRI, surgical findings, and clinical outcome. The performances of a single expert and a single novice interpreter were compared with this reference standard both before and after a period of directed education, and inter- and intraobserver agreement was determined. RESULTS: Initially the expert correctly classified significantly more fistulas than the novice (85% vs 63%, p = 0.024), but after directed education there was no significant difference, with good agreement for both the classification of the primary track (kappa = 0.71) and identification of extensions (k = 0.61). Intraobserver agreement was very good for the expert (kappa = 0.92) and novice (kappa = 0.88) for classification of the primary track and good (kappa = 0.64 and 0.74, respectively) for identification of extensions. CONCLUSION: The diagnostic accuracy for fistula in ano classification using MRI was significantly higher for one expert than for one novice, though this was rectified by a short period of directed education.  相似文献   

5.
PURPOSE: To examine the observer variation for bone scintigraphy in the detection of occult scaphoid fractures in daily practice, using only the early bone scanning images. METHODS: One hundred bone scans of patients with a suspected scaphoid fracture but negative initial radiographs were prospectively included to calculate the inter- and intraobserver variation. Three nuclear medicine physicians independently evaluated all bone scans at 2 different points in time with a 3-month interval. The observers filled out a blinded scoring sheet for each patient. They scored if a scaphoid fracture was present or not. In addition, they scored the presence or absence of another fracture. The inter- and intraobserver variation was analyzed using the kappa statistic. RESULTS: The interobserver variation showed substantial agreement for a scaphoid fracture and almost perfect agreement for another fracture. The intraobserver variation showed almost perfect agreement for both a scaphoid fracture and another fracture. CONCLUSIONS: In the present study, early static images of bone scintigraphy for suspected scaphoid fractures showed very little inter- and intraobserver variation. In addition, expertise does not seem to have a negative influence on the results. This enhances the possibility of using bone scintigraphy in daily practice.  相似文献   

6.
RATIONALE AND OBJECTIVES: The purpose of this study was to assess interobserver variability in the interpretation of gadolinium-enhanced magnetic resonance (MR) angiograms of splanchnic vessels in patients suspected of having chronic mesenteric ischemia (CMI). MATERIALS AND METHODS: Two readers blinded to the initial interpretation retrospectively reviewed gadolinium-enhanced MR angiograms obtained for suspected CMI in 26 patients (20 women and six men; age range, 23-77 years; mean age, 61 years) who also underwent conventional angiography. Each reader graded the degree of stenosis based on the percentage diameter reduction of the celiac artery (CA), superior mesenteric artery (SMA), and inferior mesenteric artery (IMA) by using a five-point ordinal scale: 0, no stenosis: 1, mild stenosis (<50%); 2, moderate stenosis (50%-75%); 3, severe stenosis (>75%); 4, occluded artery. Using the conventional angiogram as a reference standard, authors determined sensitivity and specificity for each observer, assigning two thresholds (grades 2 and 3) as significant stenoses. A kappa statistic (kappa) measured interobserver agreement. RESULTS: With grade 2 stenosis used as a threshold, cumulative accuracies for detecting significant stenosis were 0.95 (95% confidence interval, 0.86-0.99) for reader A and 0.97 (0.88-1.0) for reader B. Interobserver agreement for grading proximal splanchnic stenosis was 0.90 for CA, 0.92 for SMA, and 0.48 for IMA. CONCLUSION: Gadolinium-enhanced MR angiography is reproducibly accurate for detection of proximal splanchnic artery stenosis, with good to excellent interobserver agreement.  相似文献   

7.
PURPOSE: To retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography, performed with an integrated parallel acquisition technique for high isotropic spatial resolution, with selective digital subtraction angiography (DSA) and intravascular ultrasonography (US) for accuracy of diameter and area measurements in renal artery stenosis. MATERIALS AND METHODS: The study was approved by the institutional review board, and consent was obtained from all patients. Forty-five patients (17 women, 28 men; mean age, 62.2 years) were evaluated for suspected renal artery stenosis. Three-dimensional gadolinium-enhanced MR angiograms were acquired with isotropic spatial resolution of 0.8 x 0.8 x 0.9 mm in 23-second breath-hold with an integrated parallel acquisition technique. In-plane diameter of stenosis was measured along vessel axis, and perpendicular diameter and area of stenosis were assessed in cross sections orthogonal to vessel axis, on multiplanar reformations. Interobserver agreement between two radiologists in measurements of in-plane and perpendicular diameters of stenosis and perpendicular area of stenosis was assessed with mean percentage of difference. In a subset of patients, degree of stenosis at MR angiography was compared with that at DSA (n = 20) and intravascular US (n = 11) by using Bland-Altman plots and correlation analyses. RESULTS: Mean percentage of difference in stenosis measurement was reduced from 39.3% +/- 78.4 (standard deviation) with use of in-plane views to 12.6% +/- 9.5 with use of cross-sectional views (P < .05). Interobserver agreement for stenosis grading based on perpendicular area of stenosis was significantly better than that for stenosis grading based on in-plane diameter of stenosis (mean percentage of difference, 15.2% +/- 24.2 vs 54.9% +/- 186.9; P < .001). Measurements of perpendicular area of stenosis on MR angiograms correlated well with those on intravascular US images (r(2) = 0.90). CONCLUSION: Evaluation of cross-sectional images reconstructed from high-spatial-resolution three-dimensional gadolinium-enhanced MR renal angiographic data increases the accuracy of the technique and decreases interobserver variability.  相似文献   

8.
PURPOSE: The goal of this work was to evaluate three-dimensional (3D) contrast-enhanced MR angiography (MRA) for the detection of ostial stenoses of the aortic arch. METHOD: Sixteen patients with suspected carotid atherosclerotic disease prospectively underwent digital subtraction angiography of the aortic arch followed by contrast-enhanced MRA using a 3D fast imaging with steady-state precession (FISP) technique (TR = 5 ms, TE = 2 ms, flip angle = 30 degrees). Three neuroradiologists blindly measured stenoses on the catheter angiograms and MRA. Evaluation included the ostia of the innominate, left carotid, and left subclavian arteries. Any significant disagreement on catheter angiography was resolved by consensus. The MRA grades of each of the three observers were then compared with the consensus grades of the contrast angiogram. RESULTS: Forty-eight vessels were scored, of which five had significant stenoses. MRA demonstrated 100% sensitivity, 89% specificity, 52% positive predictive value, and 100% negative predictive value. The Bowker test for symmetry indicated no significant difference between conventional angiography and MRA scores (p = 0.32-0.75), and there was good agreement between the three observers (weighted kappa = 0.75-0.86). CONCLUSION: Contrast-enhanced 3D FISP MRA may be a useful imaging modality for the detection of significant stenoses at the ostia of the major aortic arch branches.  相似文献   

9.
OBJECTIVE: Our objective was to evaluate interobserver variability in interpretations performed by on-call radiology fellows and subsequently by attending radiologists of CT angiograms obtained for clinically suspected pulmonary embolism and to evaluate factors contributing to discrepancies. MATERIALS AND METHODS: Written interpretations made by on-call fellows were compared with reports approved by attending radiologists for all CT angiograms obtained for suspected pulmonary embolism after work hours and on weekends in a recent 19-month period. Interpretations were stratified as positive, negative, or equivocal for pulmonary embolism. In cases of discordant interpretations, those CT angiograms were rereviewed by two thoracic radiologists; then patient medical records were reviewed for evidence of clinical effect. Technical and patient-related reasons for discordant interpretations of CT angiograms were recorded. RESULTS: Six hundred fifty-eight oncology patients were examined on CT angiography; five were examined twice. The fellows reported 137 CT angiograms (21%) as positive, 498 (75%) as negative, and 28 (4%) as equivocal for pulmonary embolism. Interpretations of the fellows and attending radiologists agreed in 93% (615/663) of CT angiograms (kappa = 0.80). The concordance rates for CT angiograms interpreted by fellows as positive (89%, 122/137), negative (96%, 479/498), and equivocal (50%, 14/28) were significantly different from each other (p < 0.001 for each). A significantly greater proportion of CT angiograms with discordant interpretations was reported to be technically limited (p < 0.01). No clear adverse clinical events were attributed to discordant interpretations of CT angiograms, although the death of one patient in that subgroup was of indeterminate cause. CONCLUSION: In the evaluation of CT angiograms obtained for suspected pulmonary embolism, on-call fellows showed good agreement with attending radiologists. CT angiograms with discordant interpretations often were limited by technical or patient-related factors.  相似文献   

10.
BACKGROUND AND PURPOSE: Three-dimensional time-of-flight (TOF) MR angiography is used routinely in stroke workup to detect arterial occlusions, but a major drawback is its inadequate depiction of vessels with slow or in-plane flow. We hypothesized that the use of contrast-enhanced MR angiography improves delineation of vessels with diminished or absent flow on precontrast MR angiograms. METHODS: Pre- and postcontrast 3D TOF MR angiograms were acquired in 55 consecutive patients with acute stroke. Patency of 480 intracranial vessels was assessed on both the pre- and postcontrast angiograms. Diffusion-weighted (DW) and perfusion-weighted (PW) imaging data were also obtained and results correlated with those of pre- and postcontrast MR angiography. RESULTS: For 50 abnormal vessel segments seen on precontrast MR angiograms, postcontrast MR angiograms resulted in change in the vascular signal intensity in 70% (35 vessel segments); 94% of these changes showed a greater extent of vessel patency. Venous and soft-tissue contrast enhancement had no effect on assessment in 95% of all 480 vessels examined. Interobserver reliability was moderate, with postcontrast interpretation (kappa = 0.48) showing a slight improvement over precontrast interpretation (kappa = 0.41). Good agreement was found between the TOF results and the pooled DW and PW imaging results. CONCLUSIONS: Compared with precontrast 3D TOF MR angiograms, postcontrast 3D TOF angiograms improve assessment of intracranial vessel patency in acutely ischemic vascular territories. In some patients, an improved understanding of acute ischemic stroke was obtained by viewing the pre- and postcontrast images. Postcontrast MR angiography should be included in the MR evaluation of acute stroke.  相似文献   

11.
Fifty-two paired stress/delayed planar 201TI studies (27 exercise studies, 25 dipyridamole studies) were processed twice by seven technologists to assess inter- and intraobserver variability. The reproducibility was inversely related to the size of 201TI perfusion abnormalities. Intraobserver variability was not different between exercise and dipyridamole studies for lesions of similar size. Based upon intraobserver variability, objective quantitative criteria for reversibility of perfusion abnormalities were defined. These objective criteria were tested prospectively in a separate group of 35 201TI studies and compared with the subjective interpretation of quantitative circumferential profiles. Overall, exact agreement existed in 78% of images (kappa statistic k = 0.66). We conclude that quantification of planar 201TI scans is highly reproducible, with acceptable inter- and intraobserver variability. Objective criteria for lesion reversibility correlated well with analysis by experienced observers.  相似文献   

12.
目的评价CT肺动脉成像(CTPA)诊断肺栓塞(PE)时,不同经验的读片者间和同一读片者内的一致性。方法 55例临床可疑PE患者行CTPA检查,6位不同经验的放射科医生独立地分析CTPA图像来评价读片者间的一致性。3位放射科医生3个月后第二次分析CTPA图像来评价读片者内的一致性。PE的表现分为阳性、阴性和难以确定。读片者一致性用百分比及Kappa系数表示。结果 6位读片者判定29~31例(平均29.2例)患者CTPA为PE阳性,1~5例(平均3.0例)患者CTPA为难以确定。6位读片者在48例(87.3%)患者CTPA的诊断上取得一致意见,5位读片者在4例患者(7.3%)的诊断上取得一致意见,4位读片者在2例患者(3.6%)的诊断上取得一致意见,3位读片者在1例患者(1.8%)的诊断上取得一致意见。在诊断PE上,如果以每例患者为观察单位,读片者间的一致性"非常好"(Kappa值为0.91)。以每个肺动脉为观察单位,读片者间的一致性"好"(85%,Kappa值为0.74);以肺叶动脉为观察单位,读片者间的一致性"好"(89%,Kappa值为0.78);以肺段动脉为观察单位,读片者间的一致性"中等"(75%,Kappa值为0.59)。如果以每例患者为观察单位,同一读片者内的平均一致性"非常好"(96%,Kappa值为0.93)。结论在CTPA上诊断PE时,经验不同的读片者间和同一读片者内的一致性均较好。  相似文献   

13.
Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography.   总被引:7,自引:0,他引:7  
Two hundred seventy-five computed tomographic (CT) angiograms of the thoracic aorta were obtained over a period of approximately 4 years in patients with suspected or known aortic dissection. In all cases, unenhanced images were initially obtained, followed by contrast material-enhanced images. A variety of pitfalls were encountered that mimicked aortic dissection. These pitfalls were attributable to technical factors (eg, improper timing of contrast material administration relative to image acquisition); streak artifacts generated by high-attenuation material, high-contrast interfaces, or cardiac motion; periaortic structures (eg, aortic arch branches, mediastinal veins, pericardial recess, thymus, atelectasis, pleural thickening or effusion adjacent to the aorta); aortic wall motion and normal aortic sinuses; aortic variations such as congenital ductus diverticulum and acquired aortic aneurysm with thrombus; and penetrating atherosclerotic ulcer. Although several of these pitfalls are easy to recognize and therefore unlikely to present a diagnostic problem, others are potentially confusing. Familiarity with these common pitfalls, coupled with a knowledge of normal intrathoracic anatomy, will facilitate recognition of true aortic dissection and help avoid misdiagnosis at thoracic aortic CT angiography.  相似文献   

14.
PURPOSE: To prospectively compare the image quality, sensitivity, and specificity of three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography accelerated by parallel acquisition (ie, fast MR angiography) with MR angiography not accelerated by parallel acquisition (ie, conventional MR angiography) for assessment of aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was obtained from all patients. Forty consecutive patients (33 men, seven women; mean age, 63 years) suspected of having aortoiliac and renal arterial stenoses and thus examined with DSA underwent both fast (mean imaging time, 17 seconds) and conventional (mean imaging time, 29 seconds) MR angiography. The arterial tree was divided into segments for image analysis. Two readers independently evaluated all MR angiograms for image quality, presence of arterial stenosis, and renal arterial variants. Image quality, sensitivity, and specificity were analyzed on per-patient and per-segment bases for multiple comparisons (with Bonferroni correction) and for dependencies between segments (with patient as the primary sample unit). Interobserver agreement was evaluated by using kappa statistics. RESULTS: Overall, the image quality with fast MR angiography was significantly better (P=.001) than that with conventional MR angiography. At per-segment analysis, the image quality of fast MR angiograms of the distal renal artery tended to be better than that of conventional MR angiograms of these vessels. Differences in sensitivity for the detection of arterial stenosis between the two MR angiography techniques were not significant for either reader. Interobserver agreement in the detection of variant renal artery anatomy was excellent with both conventional and fast MR angiography (kappa=1.00). CONCLUSION: Fast MR angiography and conventional MR angiography do not differ significantly in terms of arterial stenosis grading or renal arterial variant detection.  相似文献   

15.
OBJECTIVE: The objective of this study is to describe the use of intravascular sonography in the evaluation of suspected injury of the thoracic aorta as an adjunctive tool to digital subtraction arteriography (DSA). SUBJECTS AND METHODS: Images of the thoracic aorta were obtained using DSA and intravascular sonography in 20 consecutive patients who underwent arteriography after chest trauma. A 6-French, 12.5-MHz sonography catheter was used for the intravascular sonography study. Diagnoses based on the review of both studies were compared. RESULTS: Five of 20 patients had aortic or great vessel injuries confirmed by surgery. Intravascular sonographic findings were positive (one false-positive) in seven patients, whereas DSA findings were positive in six patients (one false-positive and one false-negative). Surgery showed the lesion that was false-positive using both techniques to be a ductus diverticulum. Intravascular sonographic findings included intimal flaps, intramural lesions (hematomas), pseudoaneurysms, and perivascular hematomas. CONCLUSION: In our initial limited experience, intravascular sonography of the thoracic aorta and great vessels effectively identified traumatic injuries. Intramural injury without pseudoaneurysm formation or obvious intraluminal flap was visualized by intravascular sonography in one patient but was not detected by DSA. On the other hand, a ductus diverticulum was erroneously interpreted as trauma using both techniques. Intravascular sonography is a relatively new procedure with an obvious learning curve in the interpretation of the findings. An atypical ductus diverticulum may still be mistakenly interpreted as a sign of traumatic injury of the aorta. Familiarity with intravascular sonography in the setting of aortic trauma is necessary for correct interpretation of the images. The sonographic findings offer views of the aorta that are complementary to those of aortography.  相似文献   

16.
OBJECTIVE: The purpose of this study was to evaluate the relative value of and interobserver agreement on direct versus indirect (hematoma) signs of traumatic aortic injury using helical CT. MATERIALS AND METHODS: From April 1994 through January 1997, 40 patients who were suspected to have traumatic aortic injury and who underwent contrast-enhanced helical CT had subsequent proof or exclusion of aortic injury. All available CT scans of these patients were combined with CT scans of 13 randomly chosen patients that had been initially interpreted as negative, and clinical follow-up showed no evidence of aortic injury. Two emergency radiologists and a nonemergency radiologist who were unaware of clinical outcome performed independent review of these cases to evaluate for mediastinal hematoma, periaortic hematoma, and direct signs of aortic injury. RESULTS: Direct signs of injury were seen on helical CT by both emergency radiologists in all 17 cases of aortic injury with no false-positive interpretations. The nonemergency radiologist failed to observe subtle direct signs in two cases of aortic injury, but patient management would not have been adversely affected. All observers had more false-negative interpretations for both mediastinal hematoma and periaortic hematoma than for direct signs. Interobserver agreement was higher for direct signs (kappa = .93) than for either mediastinal hematoma (kappa = .65) or periaortic hematoma (kappa = .71). CONCLUSION: In this study, helical CT revealed direct signs of traumatic aortic injury that were more accurate and more often observed than were indirect signs. Emphasis on direct signs should improve confidence in using helical CT to evaluate traumatic aortic injury.  相似文献   

17.
BACKGROUND: Stress electrocardiography (ECG)-gated single photon emission computed tomography (SPECT) for assessment of left ventricular perfusion and function improves the confidence of interpretation and enhances specificity for detection of coronary artery disease. The reproducibility of visual interpretation of ECG-gated SPECT images and the significance of training and experience have not been reported previously in a large series of consecutive patients. We evaluated both intraobserver and interobserver agreement of interpretation of ECG-gated SPECT images among 3 cardiology trainees and 3 experienced nuclear cardiologists from 3 institutions. METHODS AND RESULTS: Three nuclear cardiologists and 3 cardiology trainees who had fulfilled American College of Cardiology/American Society of Nuclear Cardiology Core Cardiology Training Symposium (ACC/ASNC COCATS) guidelines for level II training in nuclear cardiology independently evaluated 106 consecutive technetium 99m sestamibi SPECT images with ECG gating of either the stress or rest images. All cases were interpreted blindly, twice in random sequence, without clinical data. We assessed intraobserver and interobserver agreement for myocardial perfusion, left ventricular regional and global systolic function, and overall clinical impression, by means of percent agreement and Cohen's kappa statistic. Intraobserver agreement was good (82%-92%, kappa = 0.54-0.84) for assessment of myocardial perfusion, systolic function, and overall impression. Interobserver agreement was also good, ranging from 65% to 90% (kappa = 0.32-0.76), with better agreement found for assessment of function (77%-85%, kappa = 0.52-0.7) than for perfusion (65%-80%, kappa = 0.32-0.6). For all measures, there were no significant differences in reproducibility between nuclear cardiologists and cardiology trainees. CONCLUSIONS: Interpretation of ECG-gated SPECT images has high reproducibility and agreement among both nuclear cardiologists and cardiology trainees.  相似文献   

18.
(99m)Tc-Dimercaptosuccinic acid (DMSA) scintigraphy is a frequently used diagnostic test to assess the presence and severity of cortical damage. The aim of this study is to investigate the variability in the interpretation of (99m)Tc-DMSA scans, evaluate the usefulness of oblique images, and assess their impact on scan interpretation. METHODS: Two experienced nuclear medicine physicians independently interpreted 100 (99m)Tc-DMSA scans (197 kidneys) 4 times. Interpretation was twice based on posterior projection images and twice based on posterior and posterior oblique projection images. For each kidney, the observers had to choose between the following results: normal, abnormal, and indeterminate. The indices of variability used were the percentage of agreement, kappa-statistic, and marginal homogeneity. RESULTS: Intraobserver and interobserver reproducibility (kappa-values) varied between 0.683 and 0.708 and between 0.609 and 0.671, respectively, for posterior images. Disagreement in (99m)Tc-DMSA scan interpretation occurred in 18% of kidneys within observers and in 21% of kidneys between observers when only posterior images were used. Oblique views changed the interpretation in 14% and 11.5% of kidneys for the first and second observers, respectively. The use of oblique views increased the agreement rate within and between observers (kappa-values, 0.725-0.812 and 0.768-0.732, respectively; mean agreement, 86.5 and 87.25, respectively). CONCLUSION: Oblique views were found useful in approximately 13% of kidneys and affected inter- and intraobserver variability. Our results suggest that oblique views should be used routinely in children with clinically suspected urinary tract infection to reliably interpret images.  相似文献   

19.
To evaluate the clinical utility of improved methods for radioaerosol inhalation imaging, we obtained preperfusion radioaerosol images in 107 patients (mean age = 62 years), who were referred for evaluation of suspected pulmonary embolism (PE). For each patient, we compared six-view aerosol images with accompanying perfusion scans and chest radiographs and with Xenon-133 (Xe-133) or Krypton-81m (Kr-81m) studies. Four observers at four different institutions independently evaluated aerosol-perfusion and gas-perfusion pairs, classifying the probability of PE as low, high, or indeterminate. The radioaerosol images were good to excellent in quality; excessive central deposition of activity was infrequent and did not interfere with image interpretation. The aerosol-perfusion studies showed 86% agreement with Xe-133 perfusion interpretations (n = 299) and 80% agreement with Kr-81m perfusion interpretations (n = 99). These rates of agreement were comparable with those of intraobserver agreement for gas-to-gas and aerosol-to-aerosol comparisons, and higher than interobserver agreement rates. In a limited number (n = 9) of angiographically documented cases, aerosol-perfusion and gas-perfusion studies provided accurate and equivalent diagnoses. The results suggest that radioaerosol inhalation studies, performed with improved nebulizers, are diagnostically equivalent to ventilation imaging as an adjunct to perfusion scintigraphy in evaluating patients with suspected PE.  相似文献   

20.
OBJECTIVES: (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects. METHODS: Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming. RESULTS: For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa=0.48, kappa=0.54 and kappa=0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi2-test; P=0.8440). CONCLUSIONS: A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号