首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Treatment of Acute Aortic Type B Dissection with Stent-Grafts   总被引:3,自引:0,他引:3  
Purpose: To evaluate the feasibility of endoluminal stent-grafts in the treatment of acute type B aortic dissections. Methods: In five patients with acute aortic type B dissections, sealing of the primary intimal tear with an endoluminal stent-graft was attempted. Indication for treatment was aneurysm formation in two patients and persistent pain in three patients. One of the latter also had an unstable dissection flap compromising the ostium of the superior mesenteric artery. The distance from the intimal tear to the left subclavian artery was <0.5 cm in four patients, who had typical type B dissections. In one patient with an atypical dissection the distance from the primary tear to the left subclavian artery was 4 cm. This patient had no re-entry tear. Talent tube grafts (World Medical Manufacturing Cooperation, Sunrise, FL, USA) were used in all patients. Results: Stent-graft insertion with sealing of the primary tear was successful in all patients. The proximal covered portion of the stent-graft was placed across the left subclavian artery in four patients (1× transposition of the left subclavian artery). Left arm perfusion was preserved via a subclavian steal phenomenon in the patients in whom the stent-graft covered the orifice of the left subclavian artery. The only procedural complication we observed was an asymptomatic segmental renal infarction in one patient. In the thoracic aorta thrombosis of the false aortic lumen occurred in all patients. In one patient the false lumen of the abdominal aorta thrombosed after 4 weeks; in the other three patients the status of the abdominal aorta remained unchanged compared with the situation prior to stent-graft insertion. As a late complication formation of a secondary aneurysm of the thoracic aorta was observed at the distal end of the stent-graft 3 months after the primary intervention. This aneurysm was treated by coaxial insertion of an additional stent-graft without complications. Conclusion: Endoluminal treatment of acute type B aortic dissections seems to be an attractive alternative treatment to surgical repair. Thrombosis of the false lumen of the thoracic aorta can be induced if the primary tear is sealed with a stent-graft. This could protect the dissected thoracic aorta from delayed rupture.  相似文献   

2.
The endoluminal stent-graft represents an attractive and a less invasive technique for treatment of various diseases of the descending thoracic aorta. The purpose of this study was to evaluate the Talent endovascular stent-graft for the treatment of various localized diseases of the descending thoracic aorta. Over a 3-year period, Talent thoracic endografts were placed in 40 patients with a high surgical risk, presenting a localized lesion of the descending thoracic aorta: degenerative aneurysm (n = 13), acute traumatic rupture (n = 11), acute Stanford type B aortic dissection (n = 6), false aneurysm (n = 7), and penetrating atherosclerotic ulcer (n = 3). Fifteen patients (37.5%) were treated as emergencies. The feasibility of endovascular treatment and sizing of the aorta and stent-grafts were determined preoperatively by magnetic resonance angiography (MRA) and intraoperative angiography. Immediate and mid-term technical and clinical success was assessed by clinical and MRA follow-up. Endovascular treatment was completed successfully in all 40 patients, with no conversion to open repair or intraoperative mortality. The mean operative time was 37.5 ± 7 min. The overall 30-day mortality rate was 10% (n = 4), all in emergency cases, for causes not related to the endograft. The primary technical success was 92.5%. The mean follow-up period was 15 ± 5 months. The survival rate was 95% (n = 35). Diminution of the aneurismal size was observed in 47.5% (n = 19). We conclude that endovascular treatment of the various localized diseases of the descending thoracic aorta is a promising, feasible, alternative technique to open surgery in well-selected patients.  相似文献   

3.
OBJECTIVE: The aim of this study was to evaluate the feasibility, safety, and effectiveness of endovascular stent-graft placement for the emergency treatment of acute descending thoracic aortic disease. MATERIALS AND METHODS: From January 1996 through November 2001, 18 patients underwent emergency endovascular stent-graft placement for various types of acute descending thoracic aortic disease. Five patients had Stanford type B aortic dissection, six had traumatic ruptures of the thoracic aorta, five had ruptured aortic aneurysms, and two had penetrating atherosclerotic aortic ulcers. All patients presented with life-threatening symptoms requiring treatment with stent-grafts from the emergency kit. All were at high surgical risk due to serious comorbidities. The efficacy of the procedure was assessed at follow-up studies before discharge and at 3, 6, and 12 months after intervention and yearly thereafter. RESULTS: The primary technical success rate was 78%. Four patients had primary perigraft leaks. The secondary technical success rate was 83%. One patient died 20 hr after intervention from stent-graft-related causes. Follow-up studies revealed stent-graft migration in one patient. Progression of disease was observed in one patient treated for dissection and in both patients treated for penetrating ulcers. One patient died 7 months after intervention of unknown reasons; all other patients are alive. The mean follow-up time was 17.4 months (range, 0-38 months). CONCLUSION: Emergency repair of acute descending thoracic aortic disease with stent-graft placement can be successfully accomplished and may be a promising alternative to open-chest surgery, especially in patients at high risk.  相似文献   

4.
Descending thoracic aortic diseases: stent-graft repair   总被引:24,自引:0,他引:24  
PURPOSE: To evaluate endovascular treatment of descending thoracic aorta with commercially available self-expanding stent-grafts. MATERIALS AND METHODS: Seventy patients with aortic dissection, intramural hemorrhage, degenerative and posttraumatic aneurysm, penetrating atherosclerotic ulcer, and pseudoaneurysm underwent endovascular treatment. Eleven patients had impending rupture and were treated on an emergency basis. Stent-grafts were customized or selected on the basis of spiral computed tomographic (CT) or magnetic resonance (MR) imaging measurements. Preprocedure diagnostic angiography was performed in patients with aortic dissection and in other selected patients. All procedures were performed in an operating room and monitored with digital subtraction angiography (DSA) and transesophageal echocardiography (TEE). Follow-up was at 1, 3, 6, and 12 months after treatment and yearly thereafter. RESULTS: Stent positioning was technically successful in 68 cases. At DSA and TEE, complete aneurysm or false-lumen exclusion was achieved in 66 (97%) cases. No intraoperative mortality or complications occurred. In-hospital complications included transient monoparesis (one patient) and extension of dissection into ascending aorta (one patient) that was repaired surgically. Early endoleak was observed in five (7%) patients: In three (type 2), endoleak resolved spontaneously; in one (type 1), it was persistent; and in one (type 1), treatment was converted to surgery. At long term, one (1%) patient died of aortic rupture; another, of respiratory insufficiency. Five (7%) late endoleak (type 1, one caused by migration of the stent) cases were observed. In three (4%), endovascular treatment was successful; in two (3%), surgery was performed. In one patient with persistent postimplantation syndrome, treatment was converted to surgery after successful aneurysm sealing. Procedure failure (ie, aortic disease-related mortality or conversion to surgery) occurred in six (9%) patients. CONCLUSION: Endovascular stent-graft repair is less invasive in patients with chronic and acute descending thoracic aortic aneurysm and dissection.  相似文献   

5.
Purpose To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 ± 19.2 years, range 18–85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed—for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure—resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 ± 36.6 months (range 0–139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a satisfactory follow-up despite the necessity for reintervention and graft extension in 3 of 6 cases (50%). Two patients with type B dissection died due to mesenteric ischemia despite sufficient mesenteric blood flow being restored (but too late). Two suffered from neurologic complications, 1 from paraplegia and 1 from cerebral ischemia (probably embolic), 1 from penetrating ulcer, and 1 from persistent ischemia of the kidney. Five of 9 (56%) patients with symptomatic thoracic aneurysm demonstrated endoleaks during follow-up and there was an increase in the aneurysm in 1. Conclusion Endovascular treatment is safe and effective for emergency treatment of life-threatening acute thoracic aortic syndromes. Results are encouraging, particularly for traumatic aortic ruptures. However, regular follow-up is mandatory, particularly in the other pathologies, to identify late complications of the stent-graft and to perform appropriate additional corrections as required.  相似文献   

6.
An 80-year-old woman with established giant cell arteritis presented at the authors' institution with a 6.5-cm false aneurysm of the descending thoracic aorta complicated by focal dissection and intramural hematoma after a 1-week history of acute-onset chest pain. The patient underwent uncomplicated endovascular aortic repair with a 32-mm x 15-cm TagExcluder stent-graft. After the procedure, the intramural hematoma resolved and the patient's corticosteroid and immunosuppressive therapy was repeatedly adjusted. However, the giant cell arteritis activity relapsed after 8 months with development of a similar 1.5-cm false aneurysm below the thoracic stent-graft, complicated by focal intramural hematoma. Repeat uncomplicated thoracic stent-graft implantation was performed and CT follow-up displayed resorption of the intramural hematomas with no evidence of endoleak or any new aortic pathology. This report discusses the difficult management of patients with relapsing active aortic giant cell arteritis and the potential role for endovascular thoracic aortic repair.  相似文献   

7.
The aim of this study was to evaluate the feasibility of endoluminal stent-graft placement in an angiographic suite for the treatment of emergent type-B aortic dissections and ruptured thoracic aortal aneurysms. Twenty-six patients with either urgent type-B dissection (n=8) or aneurysms (n=18) of the descending thoracic aorta were chosen for stent-graft implantation. All patients received a multidetector-row CT angiography of the whole aorta and pelvic arteries prior to stent-graft implantation. All procedures were performed in a fully equipped digital subtraction angiography (DSA) suite under general anesthesia. In 20 patients Talent LPS tube grafts and in 4 patients an Excluder graft were used. Access was achieved via surgical cut-down in the left (n=7) or right (n=19) groin. Sealing was successful in 24 patients. The proximal covered portion of the stent graft was placed across the left subclavian artery in 2 patients. Procedural success was achieved in 23 of 24 patients. One patient required a second stent-graft placement before the aneurysm was sealed. One patient with an acute perforation of the descending aorta died due to cardiac failure prior to stent-graft implantation. In 1 patient stent-graft delivery failed due to severe calcification of both common iliac arteries. Endoluminal treatment of both urgent type-B aortic dissections and thoracic aortal aneurysms with stent graft is an attractive alternative treatment to surgical repair. The placement of stent grafts in an angiographic suite is a safe and feasible method with good clinical effectiveness and, so far, good clinical outcome.  相似文献   

8.
OBJECTIVE: The purpose of our study was to investigate the clinical experience and efficiency of translumenl endovascular stent-graft insertion using commercially available vascular endoprotheses. We studied seven patients with descending aortic dissection (type B) and four patients with penetrating aortic ulcer over a median follow-up period of 254 days during the years 1997-2000, using cross-sectional CT to evaluate the extent of the dissection, the distance between the entry tear and the left subclavian artery, and the diameter of the true lumen and the false lumen. CONCLUSION: Endovascular treatment of acute and chronic aortic type B dissections and penetrating ulcer is a minimally invasive method with a low complication rate that could be considered a feasible alternative to surgical repair. Depending on the length of the dissection, we recommend the placement of two overlapping stent-grafts in the thoracic aorta to stabilize the affected thoracic aorta over a longer distance. This might provide a reliable sealing of the entry tear and should prevent further communication between the true lumen and the false lumen.  相似文献   

9.
Stent-graft placement for pseudoaneurysm of the aorta   总被引:3,自引:0,他引:3  
PURPOSE: To evaluate the use of endovascular stent-graft placement to repair pseudoaneurysm of the aorta. METHODS: Six patients were treated with stent-grafts for pseudoaneurysms located in the thoracic aorta (n=2), thoracoabdominal aorta (n=3), and abdominal aorta (n=1). Etiologies of the pseudoaneurysms included leakage from surgical graft, penetrating atherosclerotic ulcer, pneumonia, perforated esophageal ulcer, and mycotic aneurysm. All patients were clinically considered to be at high surgical risk. RESULTS: Stent-grafts were successfully placed in all patients. There was one death in the perioperative period due to massive hemoptysis before stent-grafting. Two patients died of persistent infection. One patient with persistent perigraft leak died of rupture. Two other patients needed no further therapy for pseudoaneurysm. CONCLUSION: Stent-graft placement for pseudoaneurysm of the aorta can play the role of a temporizing method prior to surgical repair in high-risk cases and be a therapeutic alternative in cases without infection or perigraft leakage.  相似文献   

10.
PURPOSE: To report our experience of endovascular stent-graft placement in patients with descending thoracic aortic dissections and aneurysms and to evaluate the feasibility, safety, and clinical outcomes of the treatment. MATERIALS AND METHODS: Stent-grafts were placed in the descending thoracic aortas of 23 patients with saccular aneurysms (n = 11) and Stanford type B chronic aortic dissections of the descending thoracic and abdominal aorta (n = 12). All stent-grafts were individually constructed of self-expandable stainless steel stents covered with polytetrafluoroethylene. Vascular access was achieved through the femoral artery in all patients. Clinical status of each patient was monitored and postoperative CT was performed within 1 month of the procedure and at 3-12-month intervals after the procedures. RESULTS: Successful exclusion of the primary entry tears of dissections and the inlets of saccular aneurysms was achieved in all but two patients with aortic dissection. The overall technical success rate was 91.3% (dissection: 10 of 12 = 83%; aneurysm: 11 of 11 = 100%). All patients in whom technical success was achieved showed complete thrombosis and significant decrease in diameter of the thoracic false lumen (preoperative: 5.3 cm +/- 0.9; postoperative: 4.3 cm +/- 0.9; P = .004) or aneurysm sac (preoperative: 5.3 cm +/- 1.7; postoperative: 2.8 cm +/- 2.5; P = .001). In addition, five patients demonstrated complete resolution of the dissected thoracic false lumen (n = 2) and aneurysm sac (n = 3). However, in all patients with aortic dissection, the abdominal aorta was not significantly changed in size (P = .302) and shape and their false lumen flows remained persistent. Immediate postoperative complications were detected in 12 patients (52%); 10 had fever, leukocytosis, and elevation of C-reactive protein, another had wound infection, and another had transient abdominal pain. Three patients died 2, 3, and 12 months after the procedure: one from septic shock, another from underlying mediastinitis, and the other from an unexplained cause. The remaining 20 patients were well after the procedure (1-9 days; mean, 3 days), without any stent-graft-related complications or discomfort (follow up period: 10-65 mo; mean: 25.1 mo +/- 15.6). The cumulative survival rate after the stent graft was 100% at 30 days and 91% at 12 months. CONCLUSIONS: For treatment of aortic dissection and saccular aneurysm of the descending thoracic aorta, endovascular stent-graft repair may be a technically feasible and effective treatment modality.  相似文献   

11.
We report the case of a patient who suffered major trauma following a motorcycle accident that resulted in multiple fractures, bilateral hemopneumothorax, pulmonary contusions, and an isthmic rupture of the aorta with a pseudoaneurysm compressing the descending aorta. This compression was responsible for distal hypotension and low flow, leading to acute renal insufficiency and massive rhabdomyolysis. Due to the critical clinical status of the patient, which prevented any type of open thoracic surgery, endovascular treatment was performed. An initial stent-graft permitted alleviation of the compression and the re-establishment of normal hemodynamic conditions, but its low position did not allow sufficient coverage of the rupture. A second stent-graft permitted total exclusion of the pseudoaneurysm while preserving the patency of the left subclavian artery.  相似文献   

12.
PURPOSE: To evaluate the usefulness of thoracic computed tomography (CT) after placement of an endovascular stent-graft for the treatment of descending thoracic aortic aneurysm. MATERIALS AND METHODS: From 1992 to 1996, 85 patients with thoracic aortic aneurysm underwent stent-graft placement. In 63 patients, thoracic CT scans were obtained both before and within 10 days after placement. The CT findings were retrospectively studied, and their clinical effect analyzed. In 20 of 63 patients, long-term follow-up CT findings were also evaluated. RESULTS: After stent-graft placement in the 63 patients, CT demonstrated an increase in pleural effusion in 46 (73%), periaortic changes in 21 (33%), perigraft leak in 13 (21%), atelectasis in six (10%), mural thrombus within the stent-graft in two (3%), and new aortic dissection in one (2%). The mean maximum diameter of the aneurysm was 58.8 mm before and 60.0 mm after stent-graft insertion. Sixty-two (98%) patients were successfully treated until discharge. Interventional procedures were performed to eliminate the leakage into the aneurysm sac in 10 patients with perigraft flow depicted at CT. Other complications were managed conservatively. CONCLUSION: Thoracic CT is useful in the treatment of patients after stent-graft insertion for the management of descending thoracic aortic aneurysm.  相似文献   

13.
PURPOSE: To investigate efficacy of stent-graft repair for the treatment of patients with chronic aortic dissection. MATERIALS AND METHODS: Fifteen patients with chronic aortic dissection were treated with endovascular stent-grafts. Entry tears were located in the descending thoracic aorta in all patients. The mean maximum diameter of the descending thoracic aorta was 47 mm +/- 8. The mean diameter of the true lumen at the same level was 20 mm +/- 5. The mean interval between diagnosis and stent-graft procedure was 32 months +/- 91. Stent-grafts were fabricated from expanded polytetrafluoroethylene and Z-stents. RESULTS: Stent-grafts were placed successfully in all patients. Two stent-grafts were required in one patient. Entry closure and thrombosis of the false lumen of the descending thoracic aorta were also achieved in all patients. No procedure-related complications were observed except for postimplantation syndrome, including fever and leukocytosis. The diameter of the true lumen was significantly increased (mean, 31 mm +/- 6) at the level of the descending thoracic aorta (P <.01) and the diameter of the aorta was significantly decreased (mean, 44 mm +/- 8) at the same level (P <.01). There were no deaths and no instances of aortic rupture during the subsequent average follow-up period of 24 months. Secondary stent-graft procedures were required to treat the abdominal component of dissection during follow-up in one patient. CONCLUSIONS: Stent-graft repair of chronic aortic dissection is a safe and effective method and may be an alternative to surgical graft replacement in selected patients. However, further evaluation is mandatory before this method is widely employed.  相似文献   

14.
主动脉壁内血肿的多层面螺旋CT诊断   总被引:17,自引:3,他引:14  
目的:评价多层面螺旋CT诊断主动脉壁内血肿的价值.材料和方法:对23例怀疑主动脉病变的患者进行多层面螺旋CT扫描并诊断为主动脉壁内血肿.两名有经验的心血管放射医师按照CT标准做出诊断.使用16排多层面螺旋CT获得1.25mm层厚(1mm重建间隔)图像,应用多平面重建、曲面重建、最大密度投影和容积重建等方法显示壁内血肿及穿透溃疡.结果:23例主动脉壁内血肿中,1例A型,22例B型;B型壁内血肿中,仅累及降主动脉的8例,胸腹主动脉受累11例,局限于腹主动脉3例;11壁内血肿伴主动脉穿透溃疡,其中2例行带膜内支架治疗.结论:多层面螺旋CT能为主动脉壁内血肿的诊断、鉴别诊断和治疗提供重要信息.  相似文献   

15.
This case report describes the endovascular treatment of an acute non-contained rupture of the descending aorta with a stent-graft as an emergency procedure. The aortic rupture was caused by a penetrating aortic ulcer. One year follow-up documents the complete recovery of the patient.  相似文献   

16.
A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all patients. The design time was reduced from 4 to 0.5 hr.  相似文献   

17.
Purpose: To describe the efficacy and value of endovascular stent-grafts for the treatment of aortic anastomotic pseudoaneurysms. Methods: Three patients with proximal aortic anastomotic pseudoaneurysms 8–15 years after prosthetic reconstruction were treated by transfemoral stent-graft implantation. In two patients the pseudoaneurysms were excluded by Talent prostheses [tube graft (n = 1), bifurcated graft (n = 1)]. In one patient an uniiliac Zenith stent-graft was implanted and an extra-anatomic crossover bypass for revascularization of the contralateral lower extremity was performed. Results: All procedures were successful with primary exclusion of the pseudoaneurysms. During the follow-up (mean 16 months) one endoleak occurred due to migration of the tube stent-graft. The endoleak was sealed successfully by implanting an additional bifurcated stent-graft. Conclusion: Stent-graft exclusion of aortic pseudoaneurysms offers a minimally invasive and safe alternative to open surgical reconstruction.  相似文献   

18.
A 74-year-old man with chronic aortic dissection was treated with an endovascular stent graft, fabricated from expanded polytetrafluoroethylene and a Z-stent. It was placed in the true lumen to close an entry tear. Closure was obtained immediately and thrombosis of the false lumen at the descending thoracic aorta was observed on computed tomography (CT) obtained 1 week later. No procedure-related complications developed. The patient is doing well with no adverse events including aortic rupture or aortic branch ischemia.  相似文献   

19.
PURPOSE: The endovascular treatment of the thoracic aorta is an effective alternative to open surgical repair and offers a therapeutic option even to patients at high risk for surgery. Our experience in the treatment of different diseases of descending thoracic aorta is reported. MATERIAL AND METHODS: Between July 1997 and January 2001, 50 patients were selected for endovascular treatment: 36/50 patients presented high risk for conventional surgery. Six patients presented clinical and imaging features suggesting impending rupture and were treated on emergency basis. The stent-graft prosthesis was individually manufactured or selected on the basis of spiral CT or MRI measurements. RESULTS: Endovascular stent positioning and deployment was technically successful in 49 cases. In one patient the tortuosity of the aortic arch prevented graft deployment. Complete aneurysm exclusion was achieved in 48 cases as assessed by post-procedure angiography and TEE. One proximal endoleak was noted and surgical conversion was performed 40 days later. There were no intraoperative mortality or complications. One patient presented extension of dissection at the 8th postoperative day and required of surgical repair. CT scan showed an endoleak in 4 cases that sealed spontaneously in three cases while the fourth case was treated by graft extension. In the long term two secondary endoleak were observed (12 and 24 months after the procedure). CONCLUSIONS: Endovascular stent-graft repair provides a less invasive opportunity to patients affected by thoracic aortic disease. Careful cases selection is the first postulate for the efficacy and safety of the procedure.  相似文献   

20.
To assess the accuracy and efficacy of intravascular ultrasound guidance obtained by an intracardiac ultrasound probe during complex aortic endografting. Between November 1999 and July 2002, 19 patients (5 female, 14 male; mean age 73.5 ± 2.1 years) underwent endovascular repair of thoracic (n = 10), complex abdominal (n = 6) and concomitant thoraco-abdominal (n = 3) aortic aneurysm. The most suitable size and configuration of the stent-graft were chosen on the basis of preoperative computed tomographic angiography (CTA) or magnetic resonance angiography (MRA). Intraoperative intravascular ultrasound imaging was obtained using a 9 Fr, 9 MHz intracardiac echocardiography (ICE) probe, 110 cm in length, inserted through a 10 Fr precurved long sheath. The endografts were deployed as planned by CTA or MRA. Before stent-graft deployment, the ICE probe allowed us to view the posterior aortic arch and descending thoraco-abdominal aorta without position-related artifacts, and to identify both sites of stent-graft positioning. After stent-graft deployment, the ICE probe allowed us to detect the need for additional modular components to internally reline the aorta in 11 patients, and to discover 2 incomplete graft expansions subsequently treated with adjunctive balloon angioplasty. In 1 patient, the ICE probe supported the decision that the patient was ineligible for the endovascular exclusion procedure. The ICE probe provides accurate information on the anatomy of the posterior aortic arch and thoracic and abdominal aortic aneurysms and a rapid identification of attachment sites and stent-graft pathology, allowing refinement and improvement of the endovascular strategy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号