首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced into the clinical microbiology laboratory as a rapid and accurate method to identify bacteria and yeasts. In this paper we describe our work on the use of MALDI-TOF MS for the identification of mycobacterial isolates. We developed a protocol for protein extraction from mycobacteria and utilized it to construct a database containing 42 clinically relevant type and reference strains of mycobacteria. The database was used to identify 104 clinical isolates of mycobacteria. All members of the Mycobacterium tuberculosis complex were identified accurately at the complex level but could not be separated at the species level. All other organisms were identified at the species level, with the exception of one strain of M. kansasii (accurately identified but with a low spectral score) and three pairs of closely related strains: M. abscessus and M. massiliense, M. mucogenicum and M. phocaicum, and M. chimaera and M. intracellulare. These pairs of organisms can currently be identified only by multilocus gene sequence analysis. We conclude that MALDI-TOF MS analysis can be incorporated into the work flow of the microbiology laboratory for rapid and accurate identification of most strains of mycobacteria isolated from solid growth media.  相似文献   

2.
The value of matrix-assisted laser desorption ionization−time of flight mass spectrometry (MALDI-TOF MS) for the identification of bacteria and yeasts is well documented in the literature. Its utility for the identification of mycobacteria and Nocardia spp. has also been reported in a limited scope. In this work, we report the specificity of MALDI-TOF MS for the identification of 162 Mycobacterium species and subspecies, 53 Nocardia species, and 13 genera (totaling 43 species) of other aerobic actinomycetes using both the MALDI-TOF MS manufacturer''s supplied database(s) and a custom database generated in our laboratory. The performance of a simplified processing and extraction procedure was also evaluated, and, similar to the results in an earlier literature report, our viability studies confirmed the ability of this process to inactivate Mycobacterium tuberculosis prior to analysis. Following library construction and the specificity study, the performance of MALDI-TOF MS was directly compared with that of 16S rRNA gene sequencing for the evaluation of 297 mycobacteria isolates, 148 Nocardia species isolates, and 61 other aerobic actinomycetes isolates under routine clinical laboratory working conditions over a 6-month period. MALDI-TOF MS is a valuable tool for the identification of these groups of organisms. Limitations in the databases and in the ability of MALDI-TOF MS to rapidly identify slowly growing mycobacteria are discussed.  相似文献   

3.
Yeast and mycobacteria can cause infections in immunocompromised patients and normal hosts. The rapid identification of these organisms can significantly improve patient care. There has been an increasing number of studies on using matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) for rapid yeast and mycobacterial identifications. However, studies on direct comparisons between the Bruker Biotyper and bioMérieux Vitek MS systems for the identification of yeast and mycobacteria have been limited. This study compared the performance of the two systems in their identification of 98 yeast and 102 mycobacteria isolates. Among the 98 yeast isolates, both systems generated species-level identifications in >70% of the specimens, of which Candida albicans was the most commonly cultured species. At a genus-level identification, the Biotyper system identified more isolates than the Vitek MS system for Candida (75/78 [96.2%]versus 68/78 [87.2%], respectively; P = 0.0426) and non-Candida yeasts (18/20 [90.0%]versus 7/20 [35.0%], respectively; P = 0.0008). For mycobacterial identification, the Biotyper system generated reliable identifications for 89 (87.3%) and 64 (62.8%) clinical isolates at the genus and species levels, respectively, from solid culture media, whereas the Vitek MS system did not generate any reliable identification. The MS method differentiated 12/21 clinical species, despite the fact that no differentiation between Mycobacterium abscessus and Mycobacterium chelonae was found by using 16S rRNA gene sequencing. In summary, the MALDI-TOF MS method provides short turnaround times and a standardized working protocol for the identification of yeast and mycobacteria. Our study demonstrates that MALDI-TOF MS is suitable as a first-line test for the identification of yeast and mycobacteria in clinical laboratories.  相似文献   

4.
5.
In recent studies evaluating the usefulness of the matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS)-based identification of yeasts for the routine diagnosis of fungal infections, preanalytical sample processing has emerged as a critical step for reliable MALDI-TOF MS outcomes, especially when the Bruker Daltonics Biotyper software was used. In addition, inadequate results often occurred due to discrepancies between the methods used for clinical testing and database construction. Therefore, we created an in-house MALDI-TOF MS library using the spectra from 156 reference and clinical yeast isolates (48 species in 11 genera), which were generated with a fast sample preparation procedure. After a retrospective validation study, our database was evaluated on 4,232 yeasts routinely isolated during a 6-month period and fast prepared for MALDI-TOF MS analysis. Thus, 4,209 (99.5%) of the isolates were successfully identified to the species level (with scores of ≥2.0), with 1,676 (39.6%) having scores of >2.3. For the remaining 23 (0.5%) isolates, no reliable identification (with scores of <1.7) was obtained. Interestingly, these isolates were almost always from species uniquely represented or not included in the database. As the MALDI-TOF MS results were, except for 23 isolates, validated without additional phenotypic or molecular tests, our proposed strategy can enhance the rapidity and accuracy of MALDI-TOF MS in identifying medically important yeast species. However, while continuous updating of our database will be necessary to enrich it with more strains/species of new and emerging yeasts, the present in-house MALDI-TOF MS library can be made publicly available for future multicenter studies.  相似文献   

6.
In recent years, matrix-assisted laser desorption-ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) has proved a rapid and reliable method for the identification of bacteria and yeasts that have already been isolated. The objective of this study was to evaluate this technology as a routine method for the identification of microorganisms directly from blood culture bottles (BCBs), before isolation, in a large collection of samples. For this purpose, 1000 positive BCBs containing 1085 microorganisms have been analysed by conventional phenotypic methods and by MALDI-TOF MS. Discrepancies have been resolved using molecular methods: the amplification and sequencing of the 16S rRNA gene or the Superoxide Dismutase gene (sodA) for streptococcal isolates. MALDI-TOF predicted a species- or genus-level identification of 81.4% of the analysed microorganisms. The analysis by episode yielded a complete identification of 814 out of 1000 analysed episodes (81.4%). MALDI-TOF identification is available for clinicians within hours of a working shift, as oppose to 18 h later when conventional identification methods are performed. Moreover, although further improvement of sample preparation for polymicrobial BCBs is required, the identification of more than one pathogen in the same BCB provides a valuable indication of unexpected pathogens when their presence may remain undetected in Gram staining. Implementation of MALDI-TOF identification directly from the BCB provides a rapid and reliable identification of the causal pathogen within hours.  相似文献   

7.
Until recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for the identification of microorganisms remained confined to research laboratories. In the last 2 years, the availability of relatively simple to use MALDI-TOF MS devices, which can be utilized in clinical microbiology laboratories, has changed the laboratory workflows for the identification of pathogens. Recently, the first prospective studies regarding the performance in routine bacterial identification showed that MALDI-TOF MS is a fast, reliable and cost-effective technique that has the potential to replace and/or complement conventional phenotypic identification for most bacterial strains isolated in clinical microbiology laboratories. For routine bacterial isolates, correct identification by MALDI-TOF MS at the species level was obtained in 84.1–93.6% of instances. In one of these studies, a protein extraction step clearly improved the overall valid identification yield, from 70.3% to 93.2%. This review focuses on the current state of use of MALDI-TOF MS for the identification of routine bacterial isolates and on the main difficulties that may lead to erroneous or doubtful identifications.  相似文献   

8.
Aero-tolerant Actinomyces spp. are an under-recognised cause of cutaneous infections, in part because identification using conventional phenotypic methods is difficult and may be inaccurate. Matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a promising new technique for bacterial identification, but with limited data on the identification of aero-tolerant Actinomyces spp. This study evaluated the accuracy of a phenotypic biochemical kit, MALDI-TOF MS and genotypic identification methods for the identification of this problematic group of organisms. Thirty aero-tolerant Actinomyces spp. were isolated from soft-tissue infections over a 2-year period. Species identification was performed by 16 s rRNA sequencing and genotypic results were compared with results obtained by API Coryne and MALDI-TOF MS. There was poor agreement between API Coryne and genotypic identification, with only 33% of isolates correctly identified to the species level. MALDI-TOF MS correctly identified 97% of isolates to the species level, with 33% of identifications achieved with high confidence scores. MALDI-TOF MS is a promising new tool for the identification of aero-tolerant Actinomyces spp., but improvement of the database is required in order to increase the confidence level of identification.  相似文献   

9.
Mycobacteria cause significant morbidity in humans. Rapid and accurate mycobacterial identification is important for improvement of patient outcomes. However, identification may be challenging due to the slow and fastidious growth of mycobacteria. Several diagnostic methods, such as biochemical, sequencing, and probe methods, are used for mycobacterial identification. We compared the matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) Biotyper system (Bruker Daltonics) to 16S rRNA/hsp65 sequencing and/or DNA probes (Gen-Probe) for mycobacterial identification. One hundred seventy-eight mycobacterial isolates grown on solid and/or broth medium were included in the study. MALDI-TOF MS identified 93.8% of the mycobacteria isolates accurately to the species level and 98.3% to the genus level, independent of the type of medium used for isolation. The identification of mycobacteria directly from cultures using MALDI-TOF MS allows for precise identification in an hour compared to traditional biochemical and phenotypic methods that can take weeks or probes and sequencing that may take a few hours. Identification by MALDI-TOF MS potentially reduces the turnaround time and cost, thereby saving resources within the health care system.  相似文献   

10.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is suitable for high-throughput and rapid diagnostics at low costs and can be considered an alternative for conventional biochemical and molecular identification systems in a conventional microbiological laboratory. First, we evaluated MALDI-TOF MS using 327 clinical isolates previously cultured from patient materials and identified by conventional techniques (Vitek-II, API, and biochemical tests). Discrepancies were analyzed by molecular analysis of the 16S genes. Of 327 isolates, 95.1% were identified correctly to genus level, and 85.6% were identified to species level by MALDI-TOF MS. Second, we performed a prospective validation study, including 980 clinical isolates of bacteria and yeasts. Overall performance of MALDI-TOF MS was significantly better than conventional biochemical systems for correct species identification (92.2% and 83.1%, respectively) and produced fewer incorrect genus identifications (0.1% and 1.6%, respectively). Correct species identification by MALDI-TOF MS was observed in 97.7% of Enterobacteriaceae, 92% of nonfermentative Gram-negative bacteria, 94.3% of staphylococci, 84.8% of streptococci, 84% of a miscellaneous group (mainly Haemophilus, Actinobacillus, Cardiobacterium, Eikenella, and Kingella [HACEK]), and 85.2% of yeasts. MALDI-TOF MS had significantly better performance than conventional methods for species identification of staphylococci and genus identification of bacteria belonging to HACEK group. Misidentifications by MALDI-TOF MS were clearly associated with an absence of sufficient spectra from suitable reference strains in the MALDI-TOF MS database. We conclude that MALDI-TOF MS can be implemented easily for routine identification of bacteria (except for pneumococci and viridans streptococci) and yeasts in a medical microbiological laboratory.Identification of bacteria and yeasts is generally based on conventional phenotypic methods, encompassing culture and growth patterns on specific media, Gram staining, and morphological and biochemical characteristics. Although results of Gram staining can be achieved within minutes, complete identification usually takes 1 or more days. In addition, tests may be difficult to interpret or inconclusive and require specialized staff. Recent molecular methods for microbial identification, such as real-time PCR, sequence analysis, or microarray analysis, have found some application in bacteriology. However, these methods do not provide the complete solution in routine bacterial identifications. To optimize care of patients with infectious diseases, there still is an urgent need for rapid and simple techniques for microbial identification.Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been used to analyze many different biological molecules. The application of microbial identification based on species-specific spectra of peptides and protein masses by mass spectrometry was first reported about 30 years ago (1). By further improvement of the technique, a rapid, accurate, easy-to-use, and inexpensive method has become available for identification of microorganisms (4, 14, 27). MALDI-TOF MS can be used for accurate and rapid identification of various microorganisms, such as Gram-positive bacteria (2, 3, 9, 10, 22, 26), Enterobacteriaceae (5), nonfermenting bacteria (6, 19-21), mycobacteria (12, 16, 24), anaerobes (10, 23), and yeasts (18, 25). Most studies have reported on MALDI-TOF MS identification of a single strain or family of microorganisms in a research setting. Only one study applied MALDI-TOF MS for identification of bacteria—but not yeasts—in conventional microbiology settings but did not evaluate the results for individual bacteria at the species level (27). In the present study, identification of bacteria by MALDI-TOF MS was extensively evaluated for both bacterial and yeast species identification in an academic medical microbiologic laboratory.  相似文献   

11.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a rapid method for the identification of bacteria. Factors that may alter protein profiles, including growth conditions and presence of exogenous substances, could hinder identification. Bacterial isolates identified by conventional methods were grown on various media and identified using the MALDI Biotyper (Bruker Daltonics, Billerica, MA) using a direct smear method and an acid extraction method. Specimens included 23 Pseudomonas isolates grown on blood agar, Pseudocel (CET), and MacConkey agar (MAC); 20 Staphylococcus isolates grown on blood agar, colistin-nalidixic acid agar (CNA), and mannitol salt agar (MSA); and 25 enteric isolates grown on blood agar, xylose lysine deoxycholate agar (XLD), Hektoen enteric agar (HE), salmonella-shigella agar (SS), and MAC. For Pseudomonas spp., the identification rate to genus using the direct method was 83% from blood, 78% from MAC, and 94% from CET. For Staphylococcus isolates, the identification rate to genus using the direct method was 95% from blood, 75% from CNA, and 95% from MSA. For enteric isolates, the identification rate to genus using the direct method was 100% from blood, 100% from MAC, 100% from XLD, 92% from HE, and 87% from SS. Extraction enhanced identification rates. The direct method of MALDI-TOF analysis of bacteria from selective and differential media yields identifications of varied confidence. Notably, Staphylococci spp. from CNA exhibit low identification rates. Extraction enhances identification rates and is recommended for colonies from this medium.  相似文献   

12.
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) was used for an extensive identification study of arthroconidial yeasts, using 85 reference strains from the CBS-KNAW yeast collection and 134 clinical isolates collected from medical centers in Qatar, Greece, and Romania. The test set included 72 strains of ascomycetous yeasts (Galactomyces, Geotrichum, Saprochaete, and Magnusiomyces spp.) and 147 strains of basidiomycetous yeasts (Trichosporon and Guehomyces spp.). With minimal preparation time, MALDI-TOF MS proved to be an excellent diagnostic tool that provided reliable identification of most (98%) of the tested strains to the species level, with good discriminatory power. The majority of strains were correctly identified at the species level with good scores (>2.0) and seven of the tested strains with log score values between 1.7 and 2.0. The MALDI-TOF MS results obtained were consistent with validated internal transcribed spacer (ITS) and/or large subunit (LSU) ribosomal DNA sequencing results. Expanding the mass spectrum database by increasing the number of reference strains for closely related species, including those of nonclinical origin, should enhance the usefulness of MALDI-TOF MS-based diagnostic analysis of these arthroconidial fungi in medical and other laboratories.  相似文献   

13.
We report here that modifications of the preanalytical steps of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification of yeasts, with regard to the original protocol provided by the manufacturers, appear to be efficient for the reliable routine identification of clinical yeast isolates in medical laboratories. Indeed, when one colony was sampled instead of five and the protein extraction protocol was modified, the performance of MALDI-TOF MS was superior to that of the API ID 32C method (discrepancies were confirmed by using molecular identification), allowing the correct identification of 94% of the 335 clinical isolates prospectively tested. We then demonstrated that the time for which the primary cultures were preincubated on CHROMagar did not impact the identification of yeasts by MALDI-TOF MS, since 95.1 and 96.2% of the 183 clinical yeast isolates prospectively tested were correctly identified after 48 and 72 h of preincubation, respectively.  相似文献   

14.
Peptide nucleic acid fluorescence in situ hybridization (PNA FISH) is a molecular diagnostic tool for the rapid detection of pathogens directly from liquid media. The aim of this study was to prospectively evaluate PNA FISH assays in comparison with culture-based matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, as a reference method, for both blood and cerebrospinal fluid (CSF) cultures, during a 1-year investigation. On the basis of the Gram stain microscopy results, four different PNA FISH commercially available assays were used (‘Staphylococcus aureus/CNS’, ‘Enterococcus faecalis/OE’, ‘GNR Traffic Light’ and ‘Yeasts Traffic Light’ PNA FISH assays, AdvanDx). The four PNA FISH assays were applied to 956 positive blood cultures (921 for bacteria and 35 for yeasts) and 11 CSF cultures. Among the 921 blood samples positive for bacteria, PNA FISH gave concordant results with MALDI-TOF MS in 908/921 (98.64%) samples, showing an agreement of 99.4% in the case of monomicrobial infections. As regards yeasts, the PNA FISH assay showed a 100% agreement with the result obtained by MALDI-TOF MS. When PNA FISH assays were tested on the 11 CSF cultures, the results agreed with the reference method in all cases (100%). PNA FISH assays provided species identification at least one work-day before the MALDI-TOF MS culture-based identification. PNA FISH assays showed an excellent efficacy in the prompt identification of main pathogens, yielding a significant reduction in reporting time and leading to more appropriate patient management and therapy in cases of sepsis and severe infections.  相似文献   

15.
The rapid and correct identification of pathogens is of paramount importance for the treatment of patients with invasive infections. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) can speed up the identification of bacteria and fungi and has quickly been embraced by medical microbiology laboratories worldwide. Different MALDI-TOF systems have been compared in studies focussing on identification rates of different pathogens. Another aspect that has not been systematically assessed is the performance in daily routine and handling, which is important especially for microbiology routine laboratories. We compared two widespread commercial systems, Microflex LT Biotyper (Bruker) and VitekMS (bioMérieux), for the identification of 210 relevant clinical yeasts under routine conditions, using a time-saving direct transfer protocol. We assessed the need for an additional extraction step, the threshold for species identification and the duration of measurements with the two systems. The tested yeasts included 34 Candida albicans isolates, 144 non-albicans Candida spp. and 32 yeasts of different genera. The results of the two MS systems were compared with that of biochemical identification and, in case of discrepancies, DNA sequencing of the internal transcribed spacer or the large subunit of ribosomal DNA. Both systems correctly identified 96.2 % of isolates [202/210, non-significant (n.s.)]. Misidentifications were observed for VitekMS only (n = 5, no major errors, n.s.). VitekMS was the slower system (19.8 vs. 8.0 min for 10 samples, p = 0.002) but had the advantage of a more effective direct transfer protocol with less need for an additional extraction step.  相似文献   

16.
Accurate species discrimination of filamentous fungi is essential, because some species have specific antifungal susceptibility patterns, and misidentification may result in inappropriate therapy. We evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for species identification through direct surface analysis of the fungal culture. By use of culture collection strains representing 55 species of Aspergillus, Fusarium and Mucorales, a reference database was established for MALDI-TOF MS-based species identification according to the manufacturer's recommendations for microflex measurements and MALDI BioTyper 2.0 software. The profiles of young and mature colonies were analysed for each of the reference strains, and species-specific spectral fingerprints were obtained. To evaluate the database, 103 blind-coded fungal isolates collected in the routine clinical microbiology laboratory were tested. As a reference method for species designation, multilocus sequencing was used. Eighty-five isolates were unequivocally identified to the species level (≥99% sequence similarity); 18 isolates producing ambiguous results at this threshold were initially rated as identified to the genus level only. Further molecular analysis definitively assigned these isolates to the species Aspergillus oryzae (17 isolates) and Aspergillus flavus (one isolate), concordant with the MALDI-TOF MS results. Excluding nine isolates that belong to the fungal species not included in our reference database, 91 (96.8%) of 94 isolates were identified by MALDI-TOF MS to the species level, in agreement with the results of the reference method; three isolates were identified to the genus level. In conclusion, MALDI-TOF MS is suitable for the routine identification of filamentous fungi in a medical microbiology laboratory.  相似文献   

17.
BackgroundThe implementation of MALDI-TOF MS for microorganism identification has changed the routine of the microbiology laboratories as we knew it. Most microorganisms can now be reliably identified within minutes using this inexpensive, user-friendly methodology. However, its application in the identification of mycobacteria isolates has been hampered by the structure of their cell wall. Improvements in the sample processing method and in the available database have proved key factors for the rapid and reliable identification of non-tuberculous mycobacteria isolates using MALDI-TOF MS.AimsThe main objective is to provide information about the proceedings for the identification of non-tuberculous isolates using MALDI-TOF MS and to review different sample processing methods, available databases, and the interpretation of the results.SourcesResults from relevant studies on the use of the available MALDI-TOF MS instruments, the implementation of innovative sample processing methods, or the implementation of improved databases are discussed.ContentInsight about the methodology required for reliable identification of non-tuberculous mycobacteria and its implementation in the microbiology laboratory routine is provided.ImplicationsMicrobiology laboratories where MALDI-TOF MS is available can benefit from its capacity to identify most clinically interesting non-tuberculous mycobacteria in a rapid, reliable, and inexpensive manner.  相似文献   

18.
This multicenter study analyzed Nocardia spp., including extraction, spectral acquisition, Bruker matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) identification, and score interpretation, using three Nocardia libraries, the Bruker, National Institutes of Health (NIH), and The Ohio State University (OSU) libraries, and compared the results obtained by each center. A standardized study protocol, 150 Nocardia isolates, and NIH and OSU Nocardia MALDI-TOF MS libraries were distributed to three centers. Following standardized culture, extraction, and MALDI-TOF MS analysis, isolates were identified using score cutoffs of ≥2.0 for species/species complex-level identification and ≥1.8 for genus-level identification. Isolates yielding a score of <2.0 underwent a single repeat extraction and analysis. The overall score range for all centers was 1.3 to 2.7 (average, 2.2 ± 0.3), with common species generally producing higher average scores than less common ones. Score categorization and isolate identification demonstrated 86% agreement between centers; 118 of 150 isolates were correctly identified to the species/species complex level by all centers. Nine strains (6.0%) were not identified by any center, and six (4.0%) of these were uncommon species with limited library representation. A categorical score discrepancy among centers occurred for 21 isolates (14.0%). There was an overall benefit of 21.2% from repeat extraction of low-scoring isolates and a center-dependent benefit for duplicate spotting (range, 2 to 8.7%). Finally, supplementation of the Bruker Nocardia MALDI-TOF MS library with both the OSU and NIH libraries increased the genus-level and species-level identification by 18.2% and 36.9%, respectively. Overall, this study demonstrates the ability of diverse clinical microbiology laboratories to utilize MALDI-TOF MS for the rapid identification of clinically relevant Nocardia spp. and to implement MALDI-TOF MS libraries developed by single laboratories across institutions.  相似文献   

19.
Early diagnosis of urinary tract infections (UTIs) is essential to avoid inadequate or unnecessary empirical antibiotic therapy. Microbiological confirmation takes 24 to 48 h. The use of screening methods, such as cytometry and automated microscopic analysis of urine sediment, allows the rapid prediction of negative samples. In addition, matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is a widely established technique in clinical microbiology laboratories used to identify microorganisms. We evaluated the ability of MALDI-TOF MS to identify microorganisms from direct urine samples and the predictive value of automated analyzers for the identification of microorganisms in urine by MALDI-TOF MS. A total of 451 urine samples from patients with suspected UTIs were first analyzed using the Sysmex UF-1000i flow cytometer, an automatic sediment analyzer with microscopy (SediMax), culture, and then processed by MALDI-TOF MS with a simple triple-centrifuged procedure to obtain a pellet that was washed and centrifuged and finally applied directly to the MALDI-TOF MS plate. The organisms in 336 samples were correctly identified, mainly those with Gram-negative bacteria (86.10%). No microorganisms were misidentified, and no Candida spp. were correctly identified. Regarding the data from autoanalyzers, the best bacteriuria cutoffs were 1,000 and 200 U/μl for UF-1000i and SediMax, respectively. It was concluded that the combination of a urine screening method and MALDI-TOF MS provided a reliable identification from urine samples, especially in those containing Gram-negative bacteria.  相似文献   

20.
ObjectivesWe propose using MALDI-TOF MS as a tool for identifying microorganisms directly from liquid cultures after enrichment of the clinical sample in the media, to obtain a rapid microbiological diagnosis and an adequate administration of the antibiotic therapy in a clinical setting.MethodsTo evaluate this approach, a series of quality control isolates were grown in thioglycollate (TG) broth and brain heart infusion (BHI) broth and extracted under four different protocols before finally being identified by MALDI-TOF MS. After establishing the best extraction protocol, we validated the method in a total of 300 liquid cultures (150 in TG broth and 150 in BHI broth) of different types of clinical samples obtained from two tertiary Spanish hospitals.ResultsThe initial evaluation showed that the extraction protocol including a 5 minute sonication step yielded 100% valid identifications, with an average score value of 2.305. In the clinical validation of the procedure, 98% of the microorganisms identified from the TG broth were correctly identified relative to 97% of those identified from the BHI broth. In 24% of the samples analysed, growth by direct sowing was only successful in the liquid medium, and no growth was observed in the direct solid agar cultures.ConclusionsUse of MALDI-TOF MS plus the sonication-based extraction method enabled direct and accurate identification of microorganisms in liquid culture media in 15 minutes, in contrast to the 24 hours of subculture required for conventional identification, allowing the administration of a targeted antimicrobial therapy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号