首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
The aim of this study was to compare the effect of graded gastric barostat distension and meal-induced fundic relaxation on the elicitation of transient lower oesophageal sphincter relaxation (TLOSR). In 15 healthy subjects, stepwise fundic distension and oesophageal manometry were performed simultaneously. Next, the effect of meal ingestion on proximal stomach volume and lower oesophageal sphincter function was studied. During stepwise barostat distension of the proximal stomach, a significant linear correlation between intragastric pressure (r = 0.91; P < 0.01) and the TLOSR rate during inflation and subsequent deflation (r = 0.96; P < 0.01) was found. A similar relationship was found for volume. In addition, after meal ingestion, the TLOSR rate increased significantly from 1.40 +/- 3 to 5.4 +/- 1.5 h-1 (P < 0.01) and 5.2 +/- 1.7 h-1 (P < 0.01), respectively, during the first and second 30-min postprandially. However, at similar calculated intragastric volumes, barostat distension led to a significantly higher TLOSR rate than the meal. Similarly, distension-induced increase in gastric wall tension, estimated from the measured bag pressure and volume using Laplace's law, was associated with significantly higher TLOSR rates (P < 0.01). In conclusion, the rate of TLOSRs in healthy volunteers is directly related to the degree of proximal gastric distension and pressure-controlled barostat distension is a more potent trigger of TLOSRs than a meal. The latter finding suggests that tension receptor activation is an important stimulus for TLOSRs.  相似文献   

2.
The reproducibility of barostat measurements was unclear. In this study, the intraday and interday reproducibility of barostat measurements of gastric tone, compliance and gastric accommodation were assessed in a canine model. A series of experiments were performed using a barostat system in 11 surgically prepared healthy dogs: (i) interday gastric tone and compliance: three sessions on three separate days; (ii) intraday gastric tone and compliance: two sessions on the same day separated by a 30-min interval; (iii) interday gastric accommodation: two sessions on two separate days, with each including a 30-min baseline and a 60-min postprandial period. The results were (i) interday gastric tone (81.2 +/- 7.5 mL vs 89.2 +/- 8.1 mL vs 86.2 +/- 13.6 mL, n = 11) and compliance (n = 8) were comparable; (ii) intraday gastric tone (87.9 +/- 17.2 mL vs 77.0 +/-14.8 mL, n = 8) and compliance (n = 8) was also similar, but with considerable individual variance; (iii) interday gastric accommodation was 320.8 +/-45.1 mL vs 287.9 +/- 31.2 mL, no significant difference (n = 8). Inter- and intraday gastric tone and compliance and interday gastric accommodation were relatively reproducible in most animals when tested under well-controlled conditions. However, considerable variations may occur in fasting gastric tone and compliance measurements in certain individuals and cautions should be given when interpreting related results.  相似文献   

3.
Abstract  Our aims were to measure the gastric volume response in excess of ingested meal volume (i.e. gastric accommodation), contribution of swallowed air to this excess, day-to-day variability of gastric volumes measured by MRI and their relationship to volumes measured by single-photon-emission computed tomography (SPECT). In 20 healthy volunteers, fasting and postprandial gastric volumes were measured after technetium99m-pertechnetate labeling of the gastric mucosa by SPECT and separately by MRI, using 3D gradient echo and 2D half-Fourier acquisition single-shot turbo spin echo (HASTE) sequences. Ten of these subjects had a second MRI exam to assess intra-individual variation. Thereafter, another 10 subjects had two MRI studies during which they ingested the nutrient in 30 or 150 mL aliquots. During MRI, the postprandial gastric volume change exceeded the ingested meal volume by 106 ± 12 mL (Mean ± SEM). The HASTE and gradient echo sequences distinguished air from fluid under fasting and postprandial conditions respectively. This postprandial excess mainly comprised air (61 ± 5 mL), which was not significantly different when ingested as 30 or 150 mL aliquots. Fasting and postprandial gastric volumes measured by MRI were generally reproducible within subjects. During SPECT, postprandial volumes increased by 158 ± 18 mL; gastric volumes measured by SPECT were higher than MRI. MRI measures gastric volumes with acceptable performance characteristics; the postprandial excess primarily consists of air, which is not affected by the mode of ingestion. Gastric volumes are technique specific and differ between MRI and SPECT.  相似文献   

4.
Background The intragastric balloon, filled with air or liquid is used before elective bariatric surgery because its efficacy is limited. This might be the consequence of altered gastric functions. Therefore, we aimed to investigate, in an animal model, the changes in gastric motility and emptying induced by long‐term insertion of a balloon used for weight reduction. Methods Ten Göttingen mini‐pigs were allocated into two groups with and without an intragastric balloon for 5 months. Balloons were inserted under endoscopy during general anesthesia and were filled with 350 mL of air. Gastric emptying was evaluated by scintigraphy. Gastric volume was measured by single photon emission computed tomography and proximal gastric compliance obtained using an electronic barostat. Changes in vagal tone were assessed by heart rate variability (HRV). Key Results After balloon insertion, gastric volume was significantly increased (2047 ± 114.8 cm3 after vs 1674 ± 142.5 cm3 before insertion, P < 0.05). Gastric compliance was also larger in balloon group (219 ± 23.4 mL mmHg?1 in balloon vs 168 ± 7.7 mL mmHg?1 in control group). Gastric emptying was reduced after insertion of the balloon (T1/2 = 204 ± 28.8 min vs 159 ± 25.4 before vs after insertion). High frequency components of the spectral analysis of HRV, representing vagal tone, were increased in balloon group. Conclusions & Inferences The proximal stomach was enlarged after the insertion of a balloon in the stomach as a consequence of an increased gastric compliance. This change in compliance was probably causative for a reduction in gastric emptying rate of solids. These alterations were associated with increased vagal tone.  相似文献   

5.
Abstract The aim of this study was to assess effects of gastric distension on gastric slow waves using internal and cutaneous electrodes and the correlation between these two measurements. The study was performed in five dogs implanted with one pair of serosal electrodes and a gastric cannula. Gastric slow waves were recorded using both cutaneous and internal electrodes in several sessions with different volumes (150-600 mL) of gastric distension with a barostat balloon. Bethanechol was injected in one of sessions. The results revealed that (i) Gastric distension reduced slow wave frequency in a volume-dependent manner and induced bradyarrhythmia at a volume of 600 mL, but had no effects on the amplitude of gastric slow waves. (ii) The cutaneous electrogastrogram (EGG) was significantly correlated with the internal recording in slow wave frequency (r = 0.88, P < 0.001) and regularity (r = 0.44, P = 0.035). (iii) The EGG amplitude was not increased when the stomach was distended but increased after bethanechol. Gastric distension volume dependently reduces slow wave frequency and induces gastric dysrhythmia at a large volume. The frequency and rhythmicity of the slow wave measured from the EGG are significantly correlated with those recorded from the internal electrodes. Relative increase in EGG amplitude reflects contractility rather than the distension of the stomach.  相似文献   

6.
Background The mechanisms of ‘idiopathic’ rapid gastric emptying, which are associated with functional dyspepsia and functional diarrhea, are not understood. Our hypotheses were that increased gastric motility and reduced postprandial gastric accommodation contribute to rapid gastric emptying. Methods Fasting and postprandial (300 kcal nutrient meal) gastric volumes were measured by magnetic resonance imaging (MRI) in 20 healthy people and 17 with functional dyspepsia; seven had normal and 10 had rapid gastric emptying. In 17 healthy people and patients, contractility was analyzed by spectral analysis of a time‐series of gastric cross‐sectional areas. Logistic regression models analyzed whether contractile parameters, fasting volume, and postprandial volume change could discriminate between health and patients with normal or rapid gastric emptying. Key Results While upper gastrointestinal symptoms were comparable, patients with rapid emptying had a higher (P = 0.002) body mass index than normal gastric emptying. MRI visualized propagating contractions at ~3 cpm in healthy people and patients. Compared with controls (0.32 ± 0.04, Mean ± SEM), the amplitude of gastric contractions in the entire stomach was higher (OR 4.1, 95% CI 1.2–14.0) in patients with rapid (0.48 ± 0.06), but not normal gastric emptying (0.20 ± 0.06). Similar differences were observed in the distal stomach. However, the propagation velocity, fasting gastric volume, and the postprandial volume change were not significantly different between patients and controls. Conclusions & Inferences MRI provides a non‐invasive and refined assessment of gastric volumes and contractility in humans. Increased gastric contractility may contribute to rapid gastric emptying in functional dyspepsia.  相似文献   

7.
The present study was performed to investigate the effect of gastrin on proximal gastric motor and sensory function. Ten healthy volunteers participated in three experiments performed in random order during: (A) continuous intravenous infusion of saline (control) or (B) gastrin (15 pmol kg-1 h-1) reaching postprandial serum gastrin levels or (C) gastrin infusion (15 pmol kg-1 h-1) preceded by acute acid inhibition with intravenous omeprazole. Proximal gastric function was evaluated using a barostat with stepwise pressure and volume distensions and volume measurements during set pressure (MDP + 2 mmHg). Gastrin significantly increased the intragastric volume compared to control during MDP + 2 mmHg (276 +/- 39 mL vs. 159 +/- 9 mL; P < 0.01) and reduced phasic slow volume wave frequency (from 1.4 +/- 0.1 to 0.7 +/- 0.1 per min; P < 0.01). During isobaric distensions gastrin increased gastric compliance (42 +/- 4 mL mmHg-1 vs. 31 +/- 3 mL mmHg-1; P < 0.05). These effects of gastrin infusion were completely abolished by pretreatment with omeprazole. Symptom perception decreased during gastrin infusion and was more dependent on pressure and wall tension than on volume. In conclusion: gastrin may have a role in regulating proximal gastric mechanics by inducing fundic relaxation and increasing gastric wall compliance. The effect of gastrin is dependent on acid secretion.  相似文献   

8.
Certain gastric disorders affect spatiotemporal parameters of the gastric slow wave. Whereas the electrogastrogram (EGG) evaluates electric potentials to determine primarily temporal parameters, fundamental physical limitations imposed by the volume conduction properties of the abdomen suggest the evaluation of gastric magnetic fields. We used a multichannel superconducting quantum interference device magnetometer to study the magnetogastrogram (MGG) in 20 normal human subjects before and after a test meal. We computed the frequency and amplitude parameters of the gastric slow wave from MGG. We identified normal gastric slow wave activity with a frequency of 2.6 +/- 0.5 cycles per minute (cpm) preprandial and 2.8 +/- 0.3 cpm postprandial. In addition to frequency and amplitude, the use of surface current density mapping applied to the multichannel MGG allowed us to visualize the propagating slow wave and compute its propagation velocity (6.6 +/- 1.0 mm s(-1) preprandial and 7.4 +/- 0.4 mm s(-1) postprandial). Whereas MGG and EGG signals exhibited strong correlation, there was very little correlation between the MGG and manometry. The MGG not only records frequency dynamics of the gastric slow wave, but also characterizes gastric propagation. The MGG primarily reflects the underlying gastric electrical activity, but not its mechanical activity.  相似文献   

9.
Gastric electrical stimulation (GES) has been applied to treat gastroparesis and morbid obesity. The aims of this study were to evaluate the sites of stimulation and the mechanisms of GES on gastric tone and accommodation. Gastric tone and accommodation were evaluated with a barostat in surgically prepared dogs. GES was applied at seven different locations, and gastric tone was assessed at each site. The effect of truncal vagotomy on gastric tone and accommodation and the role of the nitrergic pathway were also evaluated. We have found: 1) GES induced varying degrees of gastric relaxation at all tested locations in normal dogs; 2) Gastric volume was also significantly increased with GES in vagotomized dogs and the change tended to be lower than that of normal animals; 3) Gastric accommodation was reduced during GES in both the normal and vagotomized dogs and the reduction tended to be more in the vagotomized animals; 4) The GES-induced increase in gastric volume was partially abolished by intravenous nitric oxide synthase inhibitor. GES at various sites of the stomach exerts inhibitory effect on gastric tone; the most effective sites are in the antrum along the lesser or greater curvature; the inhibitory effect of GES on gastric tone is partially mediated by the vagal and nitrergic pathway.  相似文献   

10.
AIMS: To compare gastric volume responses to ingestion of isocaloric liquid or mixed (solid-liquid) meals and document the intra- and interindividual reproducibility of gastric volume measurement using single photon emission computed tomography (SPECT) imaging after i.v. 99mTc-pertechnetate. METHODS: Eight healthy volunteers performed two studies at least 9 months apart. Gastric volumes were measured after a 317 kcal liquid nutrient meal. Within 2 weeks of the second liquid meal study, participants performed a third study, ingesting an isocaloric mixed meal. The order of the mixed and second liquid meals was randomized; Bland-Altman plot displayed data on repeated studies with liquid meal and paired t-test compared gastric volumes after mixed or liquid isocaloric meals. RESULTS: Fasting and postprandial gastric volumes associated with the two liquid meals were not significantly different; inter- and intra-individual coefficients of variation were 13 and 13.8%. In response to the mixed meal, there was a lower absolute postprandial volume and lower change in gastric volume over fasting volume compared with the response to the liquid meal (P = 0.0001). CONCLUSION: The SPECT measurement of gastric volumes in response to a nutrient liquid meal is reproducible. The magnitude of the volume response is greater after the liquid meal compared with the isocaloric mixed meal.  相似文献   

11.
Gastric emptying (GE) has a considerable variability, but data on reproducibility of gastric volume measurements are sparse. We aimed to study the reproducibility of postprandial gastric volume responses and GE using magnetic resonance imaging (MRI) in healthy controls (HC) and patients with functional dyspepsia (FD). Eight HC and eight FD patients underwent a MRI study on two occasions. MR images were acquired in seated position before and up to 120 min after liquid meal administration (200 mL, 300 kcal). Fasting (V0), initial postprandial stomach volumes (V1), volume changes (V1 - V0) and meal emptying half-times (T 1/2) were determined. Intersubject and intrasubject coefficients of variation (CV(inter), CV(intra)) and Pearson's correlation coefficients (r) were calculated. T 1/2 on both occasions were (mean +/- SD) 113 +/- 28 and 121 +/- 30 min in HC (ns) and 127 +/- 31 and 128 +/- 37 min in FD (ns), respectively. In HC, CV(inter), CV(intra), r were 31%, 23%, 0.49 for V0; 13%, 7%, 0.68 for V1; 10%, 4%, 0.71 for V1 - V0 and 25%, 7%, 0.90 for T 1/2. In FD these parameters were for V0: 42%, 41%, -0.06; for V1: 18%, 10%, 0.40; for V1 - V0: 20%, 14%, 0.74 and for T 1/2: 26%, 10%, 0.84. The stomach accommodates to a given meal volume, resulting in similar and reproducible postprandial volumes within- and between-subjects. MRI provides reproducible measurements of gastric volume responses in health and disease.  相似文献   

12.
Abstract The aims were to investigate the effects of gastric electrical stimulation (GES) on autonomic function, gastric distention and tone, and central control mechanisms in gastroparetic patients. Ten gastroparetic patients refractory to standard medical therapy participated in this study and data were collected at baseline, within two weeks before surgery for implantation of GES system, and at follow‐up sessions between 6 and 12 weeks after GES therapy was initiated. In each session, electrocardiogram, electrogastrogram (EGG) and gastric barostat measurements were conducted before and after a caloric liquid meal. Positron Emission Tomography (PET) brain scans were performed on a separate day. During GES therapy there was a significant increase in the discomfort threshold for mean pressure from 21 mmHg at baseline to 25 mmHg at follow‐up, and for mean volume from 561 mL to 713 mL. A significant increase in the postprandial EGG power (amplitude) was observed between baseline and follow up. The sympathovagal balance was significantly decreased after GES therapy, indicating a significant increase in vagal activity. The cumulative PET data showed an increase in quantitative radioactive counts relative to the standardized data base in both the thalamic and caudate nuclei after chronic GES therapy. We conclude that our data suggest that the symptomatic improvement achieved by GES in gastroparesis is best explained by activation of vagal afferent pathways to influence CNS control mechanisms for nausea and vomiting accompanied by enhanced vagal efferent autonomic function and decreased gastric sensitivity to volume distention which enhances postprandial gastric accommodation.  相似文献   

13.
Sensorimotor dysfunction of the proximal stomach is considered an important mechanism for symptom generation in functional dyspepsia and related conditions. Barostat studies are used to assess gastric sensitivity to distention, compliance and meal-induced accommodation. The aim of the present study was to assess tolerance and pitfalls of gastric barostat studies at a tertiary care centre. We performed a retrospective review of patient barostat studies between 01/2000 and 12/2004 at Leuven University Hospital. We evaluated compliance with the procedure, suggestions of air leaks, unusual sensory reporting, baseline intra-balloon volumes, gastric accommodation and phasic contractions after a meal. About 98.1% of 414 scheduled gastric barostat studies were well tolerated and the majority (94.1%) were technically adequate. Interpretation was hampered in 18 (4.4%) studies because of low intra-balloon volumes and in six (1.5%) studies because of suspected air leaks. Negative accommodation was found in 69% of studies with low volumes and in 9.8% of 382 studies with adequate volumes (27% patients with previous antireflux surgery). About 94% of gastric barostat studies in patients with upper gastrointestinal symptoms are well tolerated and technically adequate. Major artefacts are due to air leak or inappropriately low volumes.  相似文献   

14.
Abstract The mechanical and secretory factors in the stomach that may be implicated in the production of symptoms are still poorly understood. To determine whether symptoms in response to postcibal gastric distention are associated with increased acid secretion, the relationship between symptoms, acid secretion and intragastric pressure in healthy subjects was investigated. Perception (by a 0–6 score questionnaire) and the gastric secretory response to a glucose test meal (by intragastric titration) was quantified either at low (2 mmHg) or at high (8 mmHg) intragastric pressure levels, maintained by feedback regulation of the air volume within a gastric bag using an electronic barostat. Low intragastric pressure produced a small gastric expansion (87 ± 26 ml; mean ± SE) that was largely unperceived (score 0.7 ± 0.5). High intragastric pressure did not increase acid secretion (15 ± 3 mEq h-1 vs 16 ± 3 mEq h-1 at low pressure), but produced symptomatic perception (score 2.5 ± 0.7) related to a marked gastric expansion (521 ± 92 ml; P < 0.05 vs low pressure for both). It was concluded that postcibal gastric hypertension induces symptoms without affecting the gastric acid secretory response to the meal.  相似文献   

15.
Three-dimensional single-photon emission computed tomography (SPECT) imaging allows noninvasive measurement of human postprandial gastric accommodation. The aim of this study was to determine whether 99mTCO4-SPECT demonstrates effects on pre- and postprandial gastric volumes of intravenous (i.v.) erythromycin lactobionate and sublingual isosorbide dinitrate, as predicted from previous literature. Twenty volunteers received no medication (controls), while 12 were randomized to either i.v. erythromycin 2 mg kg-1 over 20 min, or 10 mg sublingual isosorbide. After a 10-min preprandial SPECT measurement, a standard 300-mL, 300-kcal liquid meal was ingested, followed by a 20-min postprandial measurement. Gastric images were reconstructed from transaxial images and total volume was measured using the Analyseeth software system. Fasting gastric volume was greater with isosorbide [223 +/- 14 (SE) mL vs. 174 +/- 9 mL, control; P < 0.05], and postprandial volume was lower with erythromycin [393 +/- 27 mL vs. 582 +/- 17 mL, control; P < 0.05]. The ratio of postprandial over fasting volume and mean difference between pre- and postprandial volumes were significantly lower in both drug groups compared to controls. We conclude that 99mTCO4-SPECT imaging is able to semiquantitatively demonstrate pharmacological modulation of fasting gastric volume and postprandial accommodation in humans.  相似文献   

16.
Preganglionic neurons in the dorsal motor nucleus of the vagus (DMV) innervate most of the gastrointestinal tract; with the stomach and the cecum/proximal colon having a greater proportion of vagal input. Cecum-projecting neurons have been thought to be distinct from other preganglionic neurons due to their location within the DMV, but it is unknown whether these neurons innervate the cecum exclusively or what effect their activation has on cecal motor activity. Therefore, we investigated the extent of coinnervation of cecum and stomach by vagal neurons, their neurochemistry, and the effect of DMV stimulation on intracecal and intragastric volumes. Fluorescent retrograde tracers injected into the serosa of the cecum and stomach revealed that in the DMV 49+/-5% CTB-labeled cecum-projecting neurons also innervated the stomach. Immunocytochemical staining for nitric oxide (NO) synthase and tyrosine hydroxylase indicated that only 3+/-1% and 4+/-1% of cecum-projecting neurons contained these markers, respectively. In anesthetized rats gastric and cecal volumes were measured by prototypic miniaturized dual barostats that were developed for use in rodents. Microinjection of l-glutamate into the DMV increased gastric contractile activity and tone, and reduced on-going cecum contractile activity (2.6+/-0.7 contractions/2 min after injection versus 8.2+/-0.4 contractions/2 min before injection, N = 5). The barostat was able to detect decreases (-0.88+/-0.13 ml) and increases (0.25+/-0.05 ml) in cecum volume in response to carbachol and sodium nitroprusside, respectively. In summary, cecum-projecting neurons are not an entirely exclusive population within the DMV because a percentage of these also innervate the stomach. Central vagal stimulation can modulate both gastric and cecum contractile activity. Together, these data support a role of the vagus in neural reflexes involving gastric and large bowel motor function, such as the immediate phase of the gastrocolonic reflex.  相似文献   

17.
Functional dyspepsia (FD) is associated with impaired gastric accommodation and autonomic dysregulation. The aim of this study was to investigate the effects of autonomic manipulation on distension-induced gastric accommodation in subjects with and without FD, using a newly developed gastric barostat paradigm. Twelve healthy subjects (HS) and 18 subjects with FD had four barostat examinations each: no intervention, intravenous atropine (1 mg), vagal stimulation (mental relaxation with deep breathing) and acute stress stimulation (serial subtraction task). Intrabag pressure increased from 1 to 15 mmHg in 5 min (ramp phase), and was maintained at 15 mmHg for 5 min (tonic phase). Volume responses were analysed using predefined parameters. There were no significant group differences in accommodation variables between HS and subjects with FD. The FD group could be subdivided into two distinct subgroups: subgroup 1 (n = 7, 38%) with low maximum volume and accommodation rate, and subgroup 2 with normal accommodation (n = 11). In subgroup 1, but not in subgroup 2 atropine increased maximum volume and accommodation rate substantially. Neither mental stress nor mental relaxation changed any of the accommodation variables. In a subgroup of subjects with FD, impairment of distension-induced gastric accommodation can be improved by cholinergic blockade, but not by acute physiological autonomic manipulation.  相似文献   

18.
Cannabinoid receptor (CBR) stimulation inhibits motility and increases food intake in rodents. Effects of CBR stimulation in human gastrointestinal (GI) tract are unclear. We compared effects of dronabinol (DRO) and placebo (PLA) on GI transit, gastric volume and satiation in humans. In a double-blind, randomized study, 30 healthy volunteers were randomly assigned to DRO 5 mg b.i.d. or PLA for three doses. We measured GI functions noninvasively: day 0, Ensure satiation test to measure maximum tolerated volume (MTV) and 30-min post-Ensure symptoms; day 1, scintigraphic transit ((111)In-egg meal) and fasting and postprandial gastric volume ((99Tcm)-SPECT); day 2, 24-h colonic transit and repeat satiation test. ancova was used to compare treatment groups with gender, age, and, for the satiation test, the baseline MTV, as covariates. A log-rank test was used to assess treatment effects on gastric emptying. Planned sample size had 80% power to detect 25-30% differences in primary end points. There was an overall retardation of gastric emptying with DRO (P = 0.018); this was more pronounced in females (P = 0.011), than in males (P = 0.184). No significant treatment differences were detected for gastric volumes, MTV, post-Ensure(R) symptoms, small bowel and colonic transit. Fasting gastric volume was greater in males receiving DRO compared with PLA (238 +/- 17 vs 185 +/- 16, P = 0.04). DRO retards gastric emptying in humans; effects are gender-related. Dronabinol also increases fasting gastric volumes in males.  相似文献   

19.
Background Magnetic resonance (MR) imaging provides direct, non‐invasive measurements of gastric function and emptying. The inter‐observer variability (IOV) of MR volume measurements and the most appropriate analysis of MR data have not been established. To assess IOV of total gastric volume (TGV) and gastric content volume (GCV) measurements from MR images and the ability of standard power exponential (PowExp), and a novel linear exponential (LinExp) model to describe MR data. Methods Ten healthy volunteers received three different volumes of a liquid nutrient test meal (200–800 mL) on 3 days in a randomized order. Magnetic resonance scans were acquired using a 1.5T system every 1–5 min for 60 min. Total gastric volume and GCV were measured independently by three observers. Volume data were fitted by PowExp and LinExp models to assess postprandial volume change and gastric emptying half time (T50). Key Results An initial rise in GCV and TGV was often observed after meal ingestion, thereafter GCV and TGV decreased in an approximately linear fashion. Inter‐observer variability decreased with greater volumes from 12% at 200 mL to 6% at 600 and 800 mL. Inter‐observer variability for T50 was <5%. PowExp and LinExp models provided comparable estimates of T50; however, only LinExp described dynamic volume change in the early postprandial period. Conclusions & Inferences Gastric MR provides quantitative measurements of postprandial volume change with low IOV, unless the stomach is nearly empty. The novel LinExp model describes the dynamic volume changes in the early postprandial period more accurately than the PowExp model used in existing gastric emptying studies.  相似文献   

20.
Abstract The aim of this study was to compare in vitro various methods for recording intestinal sensitivity and compliance. Relationships between volume and pressure were determined in segments of penrose tubing and pig gut (‘artificial intestine’) using pressure increments of 2 mmHg (0–24 mmHg). We tested two direct methods of distension of the entire segments (by syringe inflation and the Mayo barostat); we also used three different balloon devices for indirect distension (a 10 cm polyethylene barostat bag, a 10 cm latex condom balloon and a 6 cm latex condom balloon). Maximal distending diameters of the recording systems were measured by injecting from 0 to 160 mL of air. The elastic properties of the balloons were also tested by distensions in air and in rigid tubes. All recording systems accurately detected a lesser compliance of the penrose drain as compared to pig gut. In absolute terms, only the compliance measured with a polyethylene barostat bag distended with a syringe was not different from the compliance of the segment as measured directly. The bellows of our barostat and the latex balloons had significant intrinsic compliances which interfered with the recorded pressure-volume curves. On the other hand, highly compliant plastic bags recorded most faithfully the compliance of artificial gut and that of non-compliant rigid tubes. For comparable volumes of distension, external diameters were larger with the 6 cm latex balloon than with the 10 cm latex balloon or the 10 cm polyethylene barostat balloon. A polyethylene bag distended with a non-compliant air injector (syringe) reflected most accurately the pressure-volume relationships of tubular structures. The different maximal diameters assumed by the three distending devices may explain, in part, why lower volumes of distension are required to elicit symptoms with smaller distending balloons in vivo.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号