首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVES: We evaluated the occlusion rate and safety of Cook detachable coils versus Gianturco coils in transcatheter closure of patent ductus arteriosus (PDA). BACKGROUND: The Cook detachable coil recently was introduced in an attempt to improve the safety of transcatheter closure of PDA. METHODS: Between January 1994 and September 1998, 272 patients underwent transcatheter PDA closure. Cook detachable coils were used in 137 patients, with a mean age of 43.9 months and weight of 13.8 kg. In 135 patients, Gianturco coils were used, with a mean age of 56.8 months and weight of 17.8 kg. The mean narrowest diameter of the PDA in the Cook detachable coil group was 2.85 mm versus 2.32 mm for the Gianturco coil group. RESULTS: The Cook detachable coil group was younger and weighed less than the Gianturco group (P < 0.05 and 0.02, respectively). Their narrowest PDA diameter was larger (P < 0.01). Embolization rate was significantly lower in the Cook coil group (9[6.5%] of 137 vs 22 (16.3%) of 135; P = < 0.013). The mean follow-up for the Cook coil group was significantly shorter (0.55 years) than for the Gianturco coil group (1.18 years; P < 0.001). On an intention-to-treat basis, complete occlusion by echocardiography was achieved in 99 (72.3%) of 137 patients in the Cook detachable coil group, which was significantly less than the Gianturco coil group (114 [84.4%] of 135; P = 0.008). CONCLUSION: Cook detachable coils for transcatheter closures of the PDA are safer than Gianturco coils. Hence, children with large ductal can be treated earlier in life. Short-term complete occlusion rate was lower in the Cook detachable coil group. This rate can be explained by a shorter follow-up time, larger ductal diameter, and the different materials used for the detachable coils.  相似文献   

2.
Transcatheter closure of patent ductus arteriosus (PDA) is now a well-established treatment alternative to surgery in many cardiology centers. Of all the methods used, transcatheter coil occlusion is the preferred therapy. For small PDA, the method using 0.038" Gianturco coils has proven safe and effective. However, this therapeutic strategy has encountered some difficulties with large PDA. This study provides an alternative strategy, using 0.052" Gianturco coil and complete closure of residual shunt with multiple coils to close large PDA. Fifteen patients underwent transcatheter coil occlusion of large ( > or = 4mm) patent ductus arteriosus. The intermediate success rate was 86.7%. There were four complications and only two patients had to be referred for surgery.  相似文献   

3.
We present the short- and intermediate-term results of transcatheter closure of patent ductus arteriosus with Gianturco coils in adolescents and adults. During a 5-year period, 55 patients (44 females, 11 males) with ages ranging from 14 to 72 years (median, 23) underwent attempted transcatheter closure of patent ductus with the Gianturco coils. The diameter of the narrowest segment of the ductus ranged from 0.8 to 7.6 mm (3.9 +/- 1.3 mm). The 55 patients were divided into three groups. Group I consisted of nine patients with a ductal diameter < or = 3 mm, group II consisted of 27 patients with a ductal diameter > 3 mm but < or = 4 mm, and group III consisted of 19 patients with a ductal diameter > 4 mm. Four- to five-loop Gianturco coils were used, which were deployed via retrograde aortic route. Multiple-coil technique was generally applied in group II patients. Balloon occlusion technique in combination with multiple-coil technique was generally used in group III patients. Deployment of coil was successful in 51 patients (93%) but failed in 4. The success rate of coil deployment in group I, II, and III were 100% (9/9), 96% (26/27), and 84% (16/19), respectively. A mean of 1.9 +/- 0.7 coils was deployed per patient. Of the four patients with unsuccessful coil deployment, three underwent surgery and one received implantation with Amplatzer duct occluder. Distal embolization of 21 coils occurred in 10 patients (3 in group II and 7 in group III), from whom 20 coils were retrieved with a gooseneck snare and 1 coil was removed during surgery. The mean diameter of ductus in the 10 patients with distal embolization was significantly larger than that in those without (5.2 +/- 1.4 vs. 3.7 +/- 1.1 mm; P < 0.01). Among the 51 patients with successful coil deployment, immediate complete closure was achieved in 20 (39%), while trivial to mild leak was present in 31 (61%). No significant complications were encountered. After a follow-up period ranging from 5 to 42 months, four patients had a small residual shunt and three underwent a second intervention with complete occlusion. None had left pulmonary artery stenosis documented with Doppler echocardiography. Transcatheter closure of ductus with the Gianturco coils is safe and feasible in the majority of adolescents and adults. Taking high embolization rate in patients with a ductus diameter > 4 mm into consideration, controlled-release coils, Buttoned device, or Amplatzer duct occluder can be a better choice.  相似文献   

4.
OBJECTIVE: To assess the immediate and mid-term results of transcatheter closure of patent ductus arteriosus (PDA) > or = 4 mm with multiple Gianturco coils. (Transcatheter closure of large PDAs using the Rashkind occluder or the buttoned device is associated with a 7-38% incidence of residual shunt.) METHODS: 19 patients (7 male, 12 female) underwent an attempt at anterograde transcatheter closure with multiple Gianturco coils of a large PDA at a median age of 3.8 yr (range 2 weeks-34 yr) and median weight of 14 kg (range 2.3-80 kg). RESULTS: The median PDA diameter at the narrowest segment was 4.3 mm (range 4-7 mm) and the mean (SD) Qp/Qs was 1.9 (0.8). Each patient had left atrial and left ventricular volume overload. A 4F catheter was used to deliver the coils in all patients. There was immediate and complete closure in 16/18; one patient had residual shunt that was closed at a second procedure and the other had spontaneous disappearance of the residual shunt at the six week visit. A short ductus (angiographic type B) in one patient could not be closed. The median number of coils placed at the first attempt to close the ductus was 4 (range 2-6 coils) and the median fluoroscopy time was 40 minutes (range 13-152 minutes). Mild left pulmonary artery stenosis occurred in the two smallest patients. Coil migration to the lung occurred in 3 patients with retrieval of coils in two patients. All procedures but one were done on an outpatient basis. At a median follow up of 1.6 yr (range 2 weeks-2.2 yr) all patients had complete closure with no new complications. CONCLUSIONS: Anterograde transcatheter closure with multiple Gianturco coils is an effective treatment for most patients with large PDA of diameters up to 7 mm. This technique can be performed in small infants on an outpatient basis without the need for general endotracheal anaesthesia.  相似文献   

5.
OBJECTIVE: We wish to present the preliminary result of transarterial occlusion of patent ductus arteriosus (PDA) with Gianturco coils in pediatric patients in central Taiwan. MATERIALS AND METHODS: We attempted occlusion of PDA with Gianturco coils in a total of 26 consecutive patients, 13 infants and 13 children, 23 female and three male, between July 1 1997 to September 30 1998. Median patient age was 2.57 years (from 0.25 to 14.02 years old). Median patient weight was 10.8 kg (4.0 to 36.0 kg). Premature babies with PDA, full-term babies who were less than three months old and patients who had other congenital heart disease were not included in this study. All PDAs were approached transarterially from the femoral artery. Coils were selected to provide a helical diameter that was twice or more the minimum ductus diameter and a length approximating five loops. In five patients who had a PDA diameter > or =3.5 mm, we used a snare technique to assist coil delivery beforehand, and to test coil stability, or to retrieve coil that had migrated to the pulmonary artery afterwards. Physical auscultation, chest radiographs and echocardiography with color Doppler were done in all patients within 24 h, and one, two, three, six and 12 months after coil occlusion. RESULTS: The median ductus minimum diameter was 2.3 mm (range, 1.0 to 4.7 mm). Fifteen patients had the megaphone type (type A), four had the window type (type B), five had the tubular type (type C), one had the aneurysmal type (type D) and one had the elongated conical type (type E). Twenty-one patients underwent single coil occlusion and five had multiple coils occlusion. Twenty-one patients had immediate angiographic closure of the ductus and disappearance of heart murmur at 15 min after the procedure. Dark-brown urine (hemoglobinuria) was found in one patient, 10 h after the first procedure, due to a mild residual ductal shunt. Two more coils were implanted in a second procedure that was performed within 24 h, and the ductus was completely occluded. The dark-brown urine regressed. At one month follow-up, four patients had mild residual ductal shunts, which were completely occluded by one more coil in three patients and by two more coils in the other patient. Malpositioned coils were deployed in five patients immediately after the procedure. In total, the closure rate at 15 min, within 24 h, and at one, two, three, six and 12 months were 81, 85, 85, 100, 100, 100 and 100%, respectively. In one year of follow-up, there was no instance of coil migration, ductus reopening or stenosis of the left pulmonary artery. CONCLUSIONS: Transarterial occlusion of PDA, with a Gianturco coil having approximately five loops, can be effectively achieved in patients with a minimum ductus diameter up to 4.7 mm. In patients with a ductus of more than 3.5 mm, the snare-assisted technique was employed advantageously to control coil delivery with accuracy and stability. Coil malposition or migration can be easily retrieved using a 10-mm Nitnol snare catheter. Hemoglobinuria, due to intravascular hemolysis, may regress within 24 h after the second attempt at coil implantation.  相似文献   

6.
Background: The Rashkind Umbrella device has proven effective in closing small to moderate size patent ductus arteriosus. A comparable early occlusion rate was also seen in PDA occlusion using Gianturco coils. This study addresses the long-term outcome of both techniques in a single centre. Methods: Review was undertaken of 522 patients with PDA who underwent transcatheter occlusion before January 1997; 244 patients (mean: age 8.0±6.7 years, weight 21.8±12.9 kg, PDA size 3.2±1.0 mm) were intended to receive the Rashkind Umbrella device and the remaining 278 patients (mean: age 6.4±5.6 years, weight 18.6±11.2 kg, PDA size 2.5±1.0 mm) would receive Gianturco coils. Deployment failure occurred in 8 patients (3%) and 6 (2%) during the initial learning curve of the Rashkind Umbrella and Gianturco coil, respectively. In the Rashkind Umbrella group, haemolysis occurred in 6, device embolisation in 3, and 1 patient died from anaesthetic sequelae. Peripheral pulmonary embolisation of coils occurred in 7 patients and all were successfully retrieved. Results: Results were analysed from 228 and 258 patients who had successful Rashkind Umbrella device and Gianturco coil deployment respectively. All had completed at least 1 year follow-up. They were evaluated clinically for residual ductal murmur and echocardiographically for a residual ductal shunt and presence of pulmonary artery or aortic obstruction. The Rashkind Umbrella group had significantly higher residual shunt compared to the Gianturco coil group at various stages of follow-up (p<0.05), 40% v 22% at 24 hours, 29% v 7% at 3 months, 25% v 4% at 6 months and 22% v 3% at 1 year. In 57 patients, a reocclusion procedure during the study period was undertaken to effect immediate complete occlusion. Mild left pulmonary artery stenosis (velocity<2 m/s) was noted in 6 patients who had multiple coils and one who had a 17 mm Rashkind Umbrella device. Conclusions: Transcatheter occlusion of PDA using the Gianturco coil is safer and more effective than the Rashkind Umbrella device. It has become the first choice for treating small to moderate size native PDA at our institution.  相似文献   

7.
Objectives . We report the use of non‐ferromagnetic embolization coils for transcatheter PDA closure. Background . Transcatheter patent ductus arteriosus (PDA) closure has been performed for 40 years. A number of devices have been used with varying degrees of success. Gianturco embolization coils have been used frequently since 1992 with excellent results. These coils are a stainless steel alloy, and create an artifact when subsequent MRI imaging is performed. Methods . Eight patients underwent right and left heart catheterization and transcatheter PDA closure. Angiography displayed a PDA with left to right shunting. The minimum PDA diameter was measured. An Inconel MReye coil was implanted using standard retrograde technique. A postimplant angiogram was performed. Evaluations were performed the following morning and after 2 months. Results . The median age was 5.5 years, median weight was 24 kg. The PDA minimum diameter was 1.7 mm (range 1.4–2.4 mm), with a median Qp:Qs=1.33:1. In all patients, the PDA was completely immediately closed using one Inconel coil. Two patients also had a small aorto‐pulmonary collateral vessel that was occluded using a separate Inconel coil. All patients had follow‐up evaluation the following day; the PDA remained completely occluded and there was no obstruction of the pulmonary artery branches or descending aorta. Seven patients had subsequent follow‐up and echocardiograms; the PDA remained completely occluded. There were no complications. Conclusion . The Inconel MReye coil is safe and effective for coil occlusion of small PDA and aorto‐pulmonary vessels. Additional studies are needed to define the maximum vessel diameter for Inconel coil occlusion. © 2008 Wiley‐Liss, Inc.  相似文献   

8.
Recent reports suggest reopening of the patent ductus arteriosus (PDA) after complete occlusion with three-loop Gianturco coils. We hypothesize that five-loop coils may produce a larger thrombus than three-loop coils, which will result in no or less probability of recanalization of PDA during follow-up. This study is designed to test this hypothesis. Follow-up echocardiographic and Doppler data of 30 patients who underwent five-loop coil occlusion of small to medium-sized PDA during a 33-month period ending December 1998 were examined. Thirty patients had no residual shunt on echo Doppler study on the day following the procedure and were followed for 6 to 30 months (median, 12) after coil implantation. At the last follow-up study, none of the patients had a residual shunt and left atrial size decreased. Careful pulsed, continuous wave, and color Doppler interrogation of left/main pulmonary artery junction and proximal descending aorta did not reveal any evidence for obstruction. The follow-up data suggest that complete occlusion of small- to medium-sized PDAs is feasible with five-loop coils without evidence for recanalization at a mean follow-up of 12 months. Much longer (2 to 5 years) follow-up data may be necessary to confirm these observations. We speculate that a greater degree of thrombosis is produced within the ductus by the five-loop coils, which in turn may be responsible for lack of shunt recurrence. We recommend use of five-loop instead of three-loop coils for transcatheter occlusion of small- to medium-sized PDAs.  相似文献   

9.
Objectives: The present study evaluates two transcatheter closure strategies utilized at a single center and makes recommendations for device selection when occluding the patent ductus arteriosus. Background: A variety of devices are available for transcatheter closure of the patent ductus arteriosus (PDA) but no guidelines exist to guide operator device choice. Methods: A total of 132 patients underwent attempted transcatheter PDA closure utilizing one of two consecutive closure strategies between January 2000 and June 2005. Strategy A (n = 64; January 2000–May 2003) utilized Gianturco coils only. Strategy B (n = 68; June 2003–June 2005) utilized a single Gianturco coil for the PDA with a minimal diameter ≤1 mm (n = 28) or an Amplatzer Duct Occluder (ADO) if the PDA diameter exceeded 1 mm (n = 40). Success was defined as complete occlusion on a follow up echocardiogram. Results: 58 of 64 (90.6%) patients treated utilizing strategy A had successful coil implantation. 68 of 68 (100%) patients treated utilizing strategy B had successful coil/device implantation. At follow up echocardiography, 32 of 44 (72.7%) strategy A patients had complete ductal closure, as compared with 57 of 58 (98.3%) strategy B patients (P < 0.0001). Stepwise logistic regression analysis identified closure strategy as the most powerful predictor of procedural success (OR = 85.9; CI 5.6–9.99). Conclusions: A transcatheter PDA closure strategy consisting of a single Gianturco coil for PDA ≤ 1 mm or an ADO for larger sized PDA (strategy B) achieves superior outcomes compared to the use of coils alone. © 2008 Wiley‐Liss, Inc.  相似文献   

10.
We observed a decrease in length of the Gianturco coils following transcatheter occlusion of the patent ductus arteriosus (PDA). Coil length was measured on chest radiograph within 24 hr of coil placement and compared to the length at the time of follow-up. Echocardiograms were also reviewed for evidence of duct recanalization. Twenty-seven patients met inclusion criteria. The median time to follow-up was 5 months (1--12 months). Twenty-four out of 27 (89%) patients had a decrease in coil length by 1.9 +/- 1.1 mm (P < 0.01). This was an average decrease of 16%. One patient had an increase in length and two patients had no change in coil length. Nineteen out of 27 patients had echocardiograms. Despite the change in coil length, there was no evidence of flow acceleration in the pulmonary artery or descending aorta. No patients had evidence of duct recanalization.  相似文献   

11.
Transcatheter occlusion of patent ductus arteriosus (PDA) using Gianturco coils (GCs) has been performed for the past decade. However, little has been written regarding anatomical and hemodynamic predictors for successful occlusion of the PDA in infants. This report is to evaluate the outcome of transcatheter occlusion of PDA in symptomatic infants less than 8 kg and to assess predictors of successful occlusion. Retrospective review of catheterization charts and cineangiograms of 42 symptomatic infants who underwent cardiac catheterization for attempted transcatheter occlusion of their PDA was conducted. The hemodynamic and angiographic data evaluated included the length/diameter (L/D) ratio, defined as the length divided by the narrowest diameter of the ductus arteriosus, and preocclusion pulmonary artery pressures. Thirty-one out of 42 patients (74%) had successful occlusion. Twenty-nine out of 42 infants had an L/D ratio > 3. Of these, 26 (90%) had successful occlusion of their PDA. Thirteen out of 42 patients had an L/D ratio < or = 3. Of these, 8 (62%) had unsuccessful occlusion. Complications encountered were transient loss of femoral arterial pulse (n = 6), coil embolization (n = 5), hemolysis (n = 2), and mild left pulmonary artery obstruction (n = 2). No permanent loss of femoral arterial pulse was noted. These complications resulted in no mortality and minimal morbidity. The L/D ratio was the strongest predictor of successful outcome, with an L/D ratio greater than 3.0 being more amenable to transcatheter occlusion (odds ratio of 4.6). Other predictors for success included lower preocclusion systolic, diastolic, and mean pulmonary artery pressure and smaller ductal diameter. Our conclusion was that infants less than 8 kg with an L/D ratio > 3.0 can safely and successfully undergo transcatheter occlusion of their PDA using transcatheter coils.  相似文献   

12.
Objectives. This report evaluates the use of Gianturco coils to close large patent ductus arteriosus (PDAs) (≥3.5 mm) and describes transvenous delivery of 0.052-in. (0.132-cm) Gianturco coils.

Background. Coil closure of PDAs has become increasingly popular. However, the technique has significant limitations when used to close large PDAs. This report evaluates patient characteristics, PDA anatomy, hemodynamic variables, delivery technique and coil geometry to determine predictors of success.

Methods. Between January 1995 and January 1997, 16 of 118 patients undergoing catheterization for PDA closure were found to have large PDAs. Their median age and weight were 14 months (range 3 months to 43 years) and 8.5 kg (range 3.5 to 73), respectively. The mean PDA diameter was 4.3 mm (range 3.5 to 5.9). Closure of PDAs was attempted using transcatheter delivery of 0.038-in. (0.096-cm) and 0.052-in. coils. Differences in clinical, anatomic, hemodynamic and technical variables between successes and failures were compared.

Results. Eleven (69%) of 16 patients had successful closure of their PDA. Failures occurred only in patients <8 months of age with an indexed PDA diameter >7 mm/m and a pulmonary/systemic flow ratio ≥2.8:1. Use of 0.052-in. coils tended to reduce the incidence of embolization and the number of coils needed for closure.

Conclusions. Patients >8 months of age can have successful closure of large PDAs with currently available Gianturco coils. The 0.052-in. Gianturco coils can be used safely to close large PDAs in infants as small as 6 kg. Increased experience and improved coil design may improve closure rates of large PDAs in infants.  相似文献   


13.
We describe our early experience with a new technique involving temporary balloon occlusion for transcathether closure of patent ductus arteriosus (PDA) using single or multiple Gianturco coils. Coil occlusion was attempted in 21 patients of median age 3 (range 1–11) years, and angiographic PDA diameter 3.0 mm ± 0.87 mm. The inflated balloon of a pulmonary wedge pressure catheter over a transductal wire was used to mechanically hold the first extruded loop of the coil at the pulmonary end of the duct. If a residual shunt persisted after the delivery of the first coil, additional coils were delivered with or without the balloon support. One to nine coils (median 2) of different sizes varying between 3–12 mm diameter and 4–15 cm length were used. Immediate angiographic occlusion rate was 47.6%. However, color Doppler (CD) at 24 hours and at 6 weeks revealed complete closure in 66.6% and 80.9%, respectively. Blood transfusion was required in 2 (9.5%) patients. Three out of 56 coils (5.4%) embolized during deployment. The use of balloon occlusion is effective and safe in the treatment of ducti up to 4.7 mm. Residual shunts tend to occlude with time. Cathet. Cardiovasc. Diagn. 41:62–70, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

14.
We report our experience with transcatheter occlusion of the small PDA using Gianturco coils comparing a single coil strategy to a "multiple coil-no residual shunt strategy". Fifteen patients (Group I) had a single coil only placed irrespective of residual shunting and 20 (Group II) were treated using the no residual shunt strategy. Age, minimal PDA diameter, PDA length and PDA types were similar between groups. Closure rates in Group I patients were 60%, 80% and 87% at <1 month, 6 months and 1 year, respectively. In Group II, the <1 month and 6 month closure rates were 100%. The costs and hospital charges for coil closure were comparable to a concurrent surgical group; the total charges (hospital plus physician) were less for Group I, but similar between Group II and the surgical group. The complication rate for coil closure was significantly less than surgical closure. From these data, transcatheter closure with multiple coils can achieve the same closure rate as surgery at similar hospital charges with fewer complications.  相似文献   

15.
Coil closure of patent ductus arteriosus (PDA) has become an accepted alternative to surgical closure in most pediatric cardiac centers. However, little is known about the mid- to long-term outcome of this procedure. Therefore, we evaluated the immediate, short-, and long-term outcome of transcatheter coil closure (TCC) of PDA using single or multiple Gianturco coils or the Gianturco-Grifka Vascular Occlusive Device (GGVOD). One hundred forty-nine patients underwent an attempt at TCC of their PDAs at a median age of 2.4 years (2 weeks to 55 years) and median weight of 13.5 kg (2.3–87 kg). There were 33 patients < 1 year of age. The median PDA minimal diameter was 2 mm (0.4–7 mm) with 26 patients whose PDA minimal diameter was > 4 mm. A 4 Fr catheter was used for coil deployment in 136 patients, a 3 Fr in 4, and an 8 Fr in 4 patients who received the GGVOD. A single coil was used in 77 patients and multiple coils (2–6) were used in 66 patients. One hundred forty-six patients had successful closure (142 had immediate complete closure and 4 had residual shunt), 3 patients failed the initial attempt (2 underwent surgical ligation and 1 had a successful second attempt a year later). Of the four patients with residual shunt, three underwent a second procedure with implantation of 1–3 coils resulting in complete closure in all and one patient had spontaneous resolution of the residual shunt. Complications were encountered in nine patients: six had coil migration with successful retrieval in four; two had left pulmonary artery stenosis (2.4 kg and 6.3 kg infants), and one patient had loss of femoral arterial pulse. The median fluoroscopy time was 16 min (2–152 min). One hundred forty-two patients had the procedure as an outpatient, five patients stayed greater than 24 hr, and two of these patients were in hospital for 1 month for noncardiac reasons. At a median follow-up interval of 3.0 years (1 month to 5.1 years), there were no episodes of delayed coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Lung perfusion scans performed at a median follow-up interval of 1.6 years in 31 patients who received multiple coils revealed 45% ± 5% blood flow to the left lung. Long-term follow-up of coil closure of PDA indicates that the technique is safe and effective for most pa-tients with PDA up to a diameter of 7 mm. Cathet. Cardiovasc. Intervent. 47:457–461, 1999. © 1999 Wiley-Liss, Inc.  相似文献   

16.
Coil occlusion of a patent ductus arteriosus (PDA) was attempted with a 0.052-inch Gianturco coil. The patients' ages and body weights at occlusion ranged from 5.8 to 19.7 (12.3+/-5.0, mean+/-SD) years and 18.9-99.1 (44.8+/-23.7) kg, respectively. Three types of 0.052-inch Gianturco coils with loop diameters (mm) and coil lengths (cm) of 6x8 (diameter x length), 8x8, or 8x10 were used. The delivery system was prepared as reported by Hays et al with slight modification. The minimal diameter and the Qp/Qs of the PDA ranged from 2.3 to 4.7 (3.4+/-0.7) mm, and 1.1-1.8 (1.5+/-0.3), respectively. There were 7 cases with type A PDA and 3 with type B, and coils were successfully deployed in all. Complete occlusion in the catheter laboratory was achieved in 4 cases. A minor leak disappeared within 24 h in 3 cases and at 3 months follow-up in 1 case. A tiny leak without a heart murmur persisted in 2 cases at 3 months' follow-up. No procedure-related complications occurred. This technique has significant advantages over previously reported techniques using a 0.038-inch coil for type B, or A PDA with a minimal diameter of 3-4 mm or more.  相似文献   

17.
We describe a novel method that allows bioptome-assisted delivery of multiple Gianturco coils simultaneously for occlusion of the large patent ductus arteriosus (PDA). Two or more coils were intertwined at one end and held by a bioptome (5.2 Fr) and pulled into a short introducer. The coils were then deployed in the PDA via a long sheath (7-11 Fr) previously placed across the duct via the femoral vein. Twelve patients (6 months to 64 years; median, 10.5 years) with large PDAs (4.7 +/- 1.3 mm; range, 3.1-8.4 mm; PA mean pressure, 40 +/- 17 mm Hg; pulse pressure 63 +/- 18 mm Hg) underwent bioptome-assisted occlusion with multiple coils at our institutions. The procedure was uneventful in nine patients (fluoroscopy time, 6-23 min) and prolonged in three patients (fluoroscopy time, 26, 72, and 120 min) because of dislodgment of the coil mass and embolization of an additional coil. Successful coil deployment was feasible in all patients. Three patients required repeat coil deployment for flow elimination (hemolysis occurred in two). Flow elimination was demonstrated on the last follow-up evaluation in all except two patients. One infant has developed significant left pulmonary artery stenosis. Bioptome-assisted PDA occlusion using multiple coils delivered simultaneously may be a promising alternative to devices for transcatheter closure of large PDAs. Cathet Cardiovasc Intervent 2001;54:95-100.  相似文献   

18.
PURPOSE: To describe the radiographic appearance of the Gianturco and the Cook detachable coils and present the clinical results in patients who underwent transcatheter closure of patent ductus arteriosus. MATERIALS AND METHODS: Between January 1994 and June 1997, eighty-two patients underwent closure of patent ductus arteriosus (PDA) using either Gianturco or Cook detachable coils. The chest x-ray and echocardiography of all patients were reviewed and the following parameters were evaluated: 1) the size of the heart (cardiothoracic ratio), 2) the position and the type of the coils in the postero-anterior and the lateral projection, 3) the number of coils used, 4) the existence of residual ductal flow, 5) Doppler velocity in the left pulmonary artery. RESULTS: Complete occlusion was achieved in 94%, and cardio-thoracic ratio regressed from 0.57 to 0.53 (p < 0.01), after a mean follow-up of 1.2 years. The identification of the different coils on the chest radiograph was successful in only 47% of cases, difficulties arising especially, when multiple coils were used. In 55 patients (67%) the coil position was judged to be optimal, in 27 patients (33%) suboptimal. The latter correlates with the presence of residual shunt. Multiple coils correlated more with a left pulmonary artery flow velocity exceeding 1.5 m/s. CONCLUSION: Coil-occlusion of patent ductus arteriosus is effective and leads to reduced cardio-thoracic ratio. Radiographic coil identification is possible but may be difficult if multiple coils are deployed. Suboptimal coil position led more often to residual PDA shunt. Multiple coils are more commonly associated with increased LPA velocities, but hemodynamic significant obstruction to flow is rare.  相似文献   

19.
Background and hypothesis: Although results of surgical ligation of the patent ductus arteriosus (PDA) in the pediatric age group are excellent, surgical management of the adult with a PDA may be more problematic. The PDA that presents in adulthood may be calcified and friable, rendering simple ligation via a thoracotomy difficult, inadequate, and hazardous. Patch closure of the ductus arteriosus from either the aortic or pulmonary artery orifice using cardiopulmonary bypass or transient aortic cross-clamping is necessary but increases surgical risks. Furthermore, older patients with diseases unrelated to their PDA and patients with Down's syndrome may have higher risks with intubation, general anesthesia, and surgery. Early results of percutaneous transcatheter occlusion of the PDA with Gianturco coils performed under sedation and local anesthesia are promising. Methods: Six adults with mean age of 39.1 years (range 23.1–62.0 years) were found to have an isolated PDA with mean minimum diameter of 2.7 mm (range 1.0–5.0 mm) at cardiac catheterization. All underwent percutaneous transcatheter occulsion of the PDA using Gianturco coils. Results: Coil implantation was successful in all patients. There were no complications and all were discharged home within 24 hours. Complete ductal occlusion was seen immediately in 4 of 6 patients (67%) while 2 of 6 (33%) had small residual leaks. However, complete occlusion was achieved in all patients by 6 months following the procedure. Conclusion: Transcatheter occlusion of the PDA using coils is safe and efficacious in adults.  相似文献   

20.
OBJECTIVES: The purpose of this study was to evaluate the feasibility, safety and efficacy of using a snare-assisted technique to coil occlude the moderate to large size patent ductus arteriosus (PDA). BACKGROUND: Transcatheter occlusion of small PDAs using Gianturco coils is safe and effective. However, in larger size PDAs and/or those with short PDA length, the procedure still carries risks of coil embolization, incomplete occlusion and failure to implant the coil. METHODS: From January 1994 to June 1997, the records of 104 consecutive snare-assisted coil occlusions of moderate to large PDAs (minimum diameter >2.0 mm) were reviewed. Immediate and intermediate outcomes including complete and partial occlusion, failure to implant and complications were analyzed with respect to ductal type and size. RESULTS: Patient age ranged from 0.1 to 70.1 years (median 3.3 years). Minimum PDA diameter ranged from 2.1 to 6.8 mm (mean 3.0 +/- 0.9 mm). Angiographic types were A-62, B-13, C-6, D-14 and E-9. Using the snare-assisted technique, coil placement was successful in 104/104 patients (100%), irrespective of size or angiographic type. Immediate complete closure was observed in 73/104 (70.2%) and was related to smaller PDA size, but not to angiographic type. Complete closure was documented in 102/104 (98.1%) at 2- to 16-month follow-up. Successful closure was unrelated to PDA size or type. Coil embolization to the pulmonary artery occurred in 3/104 (2.9%) patients and was not related to PDA size or type. The need for multiple coils was found in 28/104 patients (26.9%), and was related to larger PDA size, but not to angiographic type. CONCLUSIONS: The snare-assisted delivery technique allows successful occlusion of moderate to large PDAs up to 6.8 mm, irrespective of angiographic type. This technique permits improved control and accuracy of coil placement, and facilitates delivery of multiple coils.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号