1.
The Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) instruments were evaluated for the identification of nonfermenting gram-negative bacilli (NFGNB) by a blinded comparison to conventional biochemical or molecular methods. Two hundred NFGNB that were recovered from cultures from cystic fibrosis patients in the University of Iowa Health Care (UIHC) Microbiology Laboratory between 1 January 2006 and 31 October 2010 were sent to Mayo Clinic for analysis with the Bruker Biotyper (software version 3.0) and to bioMérieux for testing with Vitek MS (SARAMIS database version 3.62). If two attempts at direct colony testing failed to provide an acceptable MALDI-TOF identification, an extraction procedure was performed. The MS identifications from both of these systems were provided to UIHC for comparison to the biochemical or molecular identification that had been reported in the patient record. Isolates with discordant results were analyzed by 16S rRNA gene sequencing at UIHC. After discrepancy testing, the Bruker Biotyper result agreed with the biochemical or molecular method, with 72.5% of isolates to the species level, 5.5% to the complex level, and 19% to the genus level (3% not identified). The level of agreement for Vitek MS was 80% species, 3.5% complex, 6% genus, and 3.5% family (7% not identified). Both MS systems provided rapid (≤3 min per isolate) and reliable identifications. The agreement of combined species/complex/genus-level identification with the reference method was higher for the Bruker Biotyper (97% versus 89.5%, P = 0.004) but required an extraction step more often. Species-level agreement with the reference method was similar for both MS systems (72.5% and 80%, P = 0.099).  相似文献   

2.
3.
We evaluated Bruker Biotyper (version 2.0) matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) for the identification of 305 clinical isolates of staphylococci, streptococci, and related genera by comparing direct colony testing with preparatory extraction. Isolates were previously identified by use of phenotypic testing and/or 16S rRNA gene sequencing. Manufacturer-specified score cutoffs for genus- and species-level identification were used. After excluding 7 isolates not present in the Biotyper library, the Biotyper correctly identified 284 (95%) and 207 (69%) isolates to the genus and species levels, respectively, using extraction. By using direct colony testing, the Biotyper identified 168 (56%) and 60 (20%) isolates to the genus and species levels, respectively. Overall, more isolates were identified to the genus and species levels with preparatory extraction than with direct colony testing (P < 0.0001). The analysis was repeated after dividing the isolates into two subgroups, staphylococci, streptococci, and enterococci (n = 217) and "related genera" (n = 81). For the former subgroup, the extraction method resulted in the identification of 213 (98%) and 171 (79%) isolates to the genus and species levels, respectively, whereas the direct colony method identified 136 (63%) and 56 (26%) isolates to the genus and species levels, respectively. In contrast, for the subgroup of related genera, the extraction method identified 71 (88%) and 36 (44%) isolates to the genus and species levels, respectively, while the direct colony method identified 32 (40%) and 4 (5%) isolates to the genus and species levels, respectively. For both subgroups, preparatory extraction was superior to direct colony testing for the identification of isolates to the genus and species levels (P < 0.0001). Preparatory extraction is needed for the identification of a substantial proportion of Gram-positive cocci using the Biotyper method according to manufacturer-specified score cutoffs.  相似文献   

4.
The performance of the Bruker Biotyper matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometer (MS) for the identification of dermatophytes from clinical cultures was compared to that of dermatophyte identification using 28S rRNA gene sequencing. The MALDI Biotyper library (MBL; version 3.0) was used alone and in combination with a supplemented library containing an additional 20 dermatophyte spectra (S-MBL). Acquired spectra were interpreted using both the manufacturer-recommended scores (genus, ≥1.7; species, ≥2.0) and adjusted cutoff values established by this study (genus, ≥1.5; species, ≥1.7); identifications required a minimum 10% difference in scores between the top two different organisms to be considered correct. One hundred well-characterized, archived dermatophyte isolates and 71 fresh dermatophyte cultures were evaluated using both libraries and both sets of cutoff criteria. Collectively, the S-MBL significantly outperformed the MBL at both the genus (93% versus 37.4%; P < 0,0001) and species (59.6% versus 20.5%; P < 0.0001) levels when using the adjusted score criteria. Importantly, application of the lowered cutoff values significantly improved genus (P = 0.005)- and species (P < 0.0001)-level identification for the S-MBL, without leading to an increase in misidentifications. MALDI-TOF MS is a cost-effective and rapid alternative to traditional or molecular methods for dermatophyte identification, provided that the reference library is supplemented to sufficiently encompass clinically relevant, intraspecies strain diversity.  相似文献   

5.
Matrix-associated laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a rapid and simple microbial identification method. Previous reports using the Biotyper system suggested that this technique requires a preliminary extraction step to identify Gram-positive rods (GPRs), a technical issue that may limit the routine use of this technique to identify pathogenic GPRs in the clinical setting. We tested the accuracy of the MALDI-TOF MS Andromas strategy to identify a set of 659 GPR isolates representing 16 bacterial genera and 72 species by the direct colony method. This bacterial collection included 40 C. diphtheriae, 13 C. pseudotuberculosis, 19 C. ulcerans, and 270 other Corynebacterium isolates, 32 L. monocytogenes and 24 other Listeria isolates, 46 Nocardia, 75 Actinomyces, 18 Actinobaculum, 11 Propionibacterium acnes, 18 Propionibacterium avidum, 30 Lactobacillus, 21 Bacillus, 2 Rhodococcus equi, 2 Erysipelothrix rhusiopathiae, and 38 other GPR isolates, all identified by reference techniques. Totals of 98.5% and 1.2% of non-Listeria GPR isolates were identified to the species or genus level, respectively. Except for L. grayi isolates that were identified to the species level, all other Listeria isolates were identified to the genus level because of highly similar spectra. These data demonstrate that rapid identification of pathogenic GPRs can be obtained without an extraction step by MALDI-TOF mass spectrometry.  相似文献   

6.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS) of intact bacteria yields a reproducible spectrum depending upon growth conditions, strain, or species. Using whole viable bacteria we describe here the application of MALDI-TOF-MS to the identification of coagulase-negative staphylococci (CoNS). Our aim was, once a bacterium has been recognized as Micrococcaceae, to identify peaks in the spectrum that can be used to identify the species or subspecies. MALDI-TOF-MS was performed using bacteria obtained from one isolated colony. One reference strain for each of the 23 clinically relevant species or subspecies of Micrococcaceae was selected. For each reference strain, the MALDI-TOF-MS profile of 10 colonies obtained from 10 different passages was analyzed. For each strain, only peaks that were conserved in the spectra of all 10 isolated colonies and with a relative intensity above 0.1 were retained, thus leading to a set of 3 to 14 selected peaks per strain. The MALDI-TOF-MS profile of 196 tested strains was then compared with that of the set of selected peaks of each of the 23 reference strains. In all cases the best hit was with the set of peaks of the reference strain belonging to the same species as that of the tested strain, thus demonstrating that the 23 sets of selected peaks can be used as a database for the rapid species identification of CoNS. Similar results were obtained using four different growth conditions. Extending this strategy to other groups of relevant pathogenic bacteria will allow rapid bacterial identification.  相似文献   

7.
The identification of nonfermenting gram-negative bacilli isolated from cystic fibrosis (CF) patients is usually achieved by using phenotype-based techniques and eventually molecular tools. These techniques remain time-consuming, expensive, and technically demanding. We used a method based on matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS) for the identification of these bacteria. A set of reference strains belonging to 58 species of clinically relevant nonfermenting gram-negative bacilli was used. To identify peaks discriminating between these various species, the profile of 10 isolated colonies obtained from 10 different passages was analyzed for each referenced strain. Conserved peaks with a relative intensity greater than 0.1 were retained. The spectra of 559 clinical isolates were then compared to that of each of the 58 reference strains as follows: 400 Pseudomonas aeruginosa, 54 Achromobacter xylosoxidans, 32 Stenotrophomonas maltophilia, 52 Burkholderia cepacia complex (BCC), 1 Burkholderia gladioli, 14 Ralstonia mannitolilytica, 2 Ralstonia pickettii, 1 Bordetella hinzii, 1 Inquilinus limosus, 1 Cupriavidus respiraculi, and 1 Burkholderia thailandensis. Using this database, 549 strains were correctly identified. Nine BCC strains and one R. mannnitolilytica strain were identified as belonging to the appropriate genus but not the correct species. We subsequently engineered BCC- and Ralstonia-specific databases using additional reference strains. Using these databases, correct identification for these species increased from 83 to 98% and from 94 to 100% of cases, respectively. Altogether, these data demonstrate that, in CF patients, MALDI-TOF-MS is a powerful tool for rapid identification of nonfermenting gram-negative bacilli.  相似文献   

8.
9.
Rapid and cost-effective matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based systems will replace conventional phenotypic methods for routine identification of bacteria. We report here the first evaluation of the new MALDI-TOF MS-based Vitek MS system in a large clinical microbiology laboratory. This system uses an original spectrum classifier algorithm and a specific database designed for the identification of clinically relevant species. We have tested 767 routine clinical isolates representative of 50 genera and 124 species. Vitek MS-based identifications were performed by means of a single deposit on a MALDI disposable target without any prior extraction step and compared with reference identifications obtained mainly with the VITEK2 phenotypic system; if the identifications were discordant, molecular techniques provided reference identifications. The Vitek MS system provided 96.2% correct identifications to the species level (86.7%), to the genus level (8.2%), or within a range of species belonging to different genera (1.3%). Conversely, 1.3% of isolates were misidentified and 2.5% were unidentified, partly because the species was not included in the database; a second deposit provided a successful identification for 0.8% of isolates unidentified with the first deposit. The Vitek MS system is a simple, convenient, and accurate method for routine bacterial identification with a single deposit, considering the high bacterial diversity studied and as evidenced by the low prevalence of species without correct identification. In addition to a second deposit in uncommon cases, expanding the spectral database is expected to further enhance performances.  相似文献   

10.
This study was undertaken to evaluate matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for the rapid identification of beta-hemolytic streptococci. We compared Bruker Biotyper 2.0 with Vitek2 coupled to the agglutination test. MALDI-TOF MS analysis of 386 beta-hemolytic streptococcal isolates yielded high-confidence identification to the species level for all 386 isolates. The Vitek2 gave high-confidence identification to the species level for 88% of Streptococcus agalactiae isolates (n = 269/306), 92% of Streptococcus pyogenes isolates (n = 48/52), and 39% of isolates of Streptococcus dysgalactiae serogroups C and G (n = 11/28).  相似文献   

11.
The performance of matrix-assisted laser desorption-ionization time of flight mass spectrometry (MALDI-TOF MS) for species identification of Prevotella was evaluated and compared with 16S rRNA gene sequencing. Using a Bruker database, 62.7% of the 102 clinical isolates were identified to the species level and 73.5% to the genus level. Extension of the commercial database improved these figures to, respectively, 83.3% and 89.2%. MALDI-TOF MS identification of Prevotella is reliable but needs a more extensive database.  相似文献   

12.
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry is used for the determination of molecular weights of different chemical compounds. We describe here the use of MALDI-TOF mass spectrometry to detect a carbapenem antibiotic, meropenem, and its degradation products. Buffered meropenem solution (0.1 mM Tris-HCl, pH 6.8) was mixed with an overnight culture of bacteria. After 3-h incubation, the reaction mixture was centrifuged, and the supernatant was analyzed by MALDI-TOF mass spectrometry. The presence or absence of peaks representing meropenem and its sodium salts was crucial. The average turnaround time of this test, considering the use of overnight culture, is 4 h. We validated this method for the detection of resistance to carbapenems in Enterobacteriaceae and Pseudomonas aeruginosa mediated by carbapenemase production. A total of 124 strains, including 30 carbapenemase-producing strains, were used in the study. The sensitivity of this method is 96.67%, with a specificity of 97.87%. Our results demonstrate the ability of this method to routinely detect carbapenemases in Enterobacteriaceae and Pseudomonas spp. in laboratories. This assay is comparable with a labor-intensive imipenem-hydrolyzing spectrophotometric assay that is a reference method for the detection of carbapenemase. As demonstrated here, MALDI-TOF mass spectrometry may be used in microbiological laboratories not only for microbial identification but also for other applications, such as studies of mechanisms of antibiotic resistance.  相似文献   

13.
14.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was evaluated prospectively in a diagnostic laboratory. Nine hundred twenty-seven organisms were tested in triplicate; 2,351/2,781 (85%) species and 2,681/2,781 (96%) genus identifications were correct. Known issues such as the misidentification of alpha-hemolytic streptococci as Streptococcus pneumoniae were easily corrected. Identifications cost AUD$0.45 per isolate and were available in minutes. MALDI-TOF MS is rapid, accurate, and inexpensive.  相似文献   

15.
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry was compared to phenotypic testing for yeast identification. MALDI-TOF mass spectrometry yielded 96.3% and 84.5% accurate species level identifications (spectral scores, ≥ 1.8) for 138 common and 103 archived strains of yeast. MALDI-TOF mass spectrometry is accurate, rapid (5.1 min of hands-on time/identification), and cost-effective ($0.50/sample) for yeast identification in the clinical laboratory.  相似文献   

16.
Dermatophytes are keratinolytic fungi responsible for a wide variety of diseases of glabrous skin, nails, and hair. Their identification, currently based on morphological criteria, is hindered by intraspecies morphological variability and the atypical morphology of some clinical isolates. The aim of this study was to evaluate matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) as a routine tool for identifying dermatophyte and Neoscytalidium species, both of which cause dermatomycoses. We first developed a spectral database of 12 different species of common and unusual dermatophytes and two molds responsible for dermatomycoses (Neoscytalidium dimidiatum and N. dimidiatum var. hyalinum). We then prospectively tested the performance of the database on 381 clinical dermatophyte and Neoscytalidium isolates. Correct identification of the species was obtained for 331/360 dermatophytes (91.9%) and 18/21 Neoscytalidium isolates (85.7%). The results of MALDI-TOF MS and standard identification disagreed for only 2 isolates. These results suggest that MALDI-TOF MS could be a useful tool for routine and fast identification of dermatophytes and Neoscytalidium spp. in clinical mycology laboratories.  相似文献   

17.
Compared to DNA sequence analysis, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) correctly identified 100% of Cryptococcus species, distinguishing the notable pathogens Cryptococcus neoformans and C. gattii. Identification was greatly enhanced by supplementing a commercial spectral library with additional entries to account for subspecies variability.  相似文献   

18.
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry is a rapid and accurate tool for the identification of many microorganisms. We assessed this technology for the identification of 103 Haemophilus parainfluenzae, Aggregatibacter aphrophilus, Aggregatibacter actinomycetemcomitans, Cardiobacterium hominis, Eikenella corrodens, and Kingella kingae (HACEK) clinical isolates and 20 Haemophilus influenzae clinical isolates. Ninety-three percent of HACEK organisms were identified correctly to the genus level using the Bruker database, and 100% were identified to the genus level using a custom database that included clinical isolates.  相似文献   

19.
A study was performed to compare matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF-MS), linked to a recently engineered microbial identification database, and two rapid identification (ID) automated systems, BD Phoenix (Becton Dickinson Diagnostic Systems, France) and VITEK-2 (bioMérieux, Marcy L'Etoile, France), for the ID of coagulase-negative staphylococci (CoNS). Two hundred and thirty-four clinical isolates of CoNS representing 20 species were analyzed. All CoNS isolates were characterized by sodA gene sequencing, allowing interpretation of the ID results obtained using the respective database of each apparatus. Overall correct ID results were obtained in 93.2%, 75.6% and 75.2% of the cases with the MALDI-TOF-MS, Phoenix and VITEK-2 systems, respectively. Mis-ID and absence of results occurred in 1.7% and 5.1% of the cases with MALDI-TOF-MS, in 23.1% and 1.3% with the Phoenix, and in 13.7% and 0.9% with the VITEK-2 systems, respectively. In addition, with the latter automate, 10.3% of the IDs were proposed with remote possibility. When excluding the CoNS species not included in the databases of at least one of the three systems, the final percentage of correct results, Mis-ID and absence of ID were 97.4%, 1.3% and 1.3% with MALDI-TOF-MS, 79%, 21% and 0% with the Phoenix, and 78.6%, 10.3% and 0.9% with the VITEK-2 system, respectively. The present study demonstrates the robustness and high sensitivity of our microbial identification database used with MALDI-TOF-MS technology. This approach represents a powerful tool for the fast ID of clinical CoNS isolates.  相似文献   

20.
Zygomycetes of the order Mucorales can cause life-threatening infections in humans. These mucormycoses are emerging and associated with a rapid tissue destruction and high mortality. The resistance of Mucorales to antimycotic substances varies between and within clinically important genera such as Mucor, Rhizopus, and Lichtheimia. Thus, an accurate diagnosis before onset of antimycotic therapy is recommended. Matrix-assisted laser desorption ionization (MALDI)-time of flight (TOF) mass spectrometry (MS) is a potentially powerful tool to rapidly identify infectious agents on the species level. We investigated the potential of MALDI-TOF MS to differentiate Lichtheimia species, one of the most important agents of mucormycoses. Using the Bruker Daltonics FlexAnalysis (version 3.0) software package, a spectral database library with m/z ratios of 2,000 to 20,000 Da was created for 19 type and reference strains of clinically relevant Zygomycetes of the order Mucorales (12 species in 7 genera). The database was tested for accuracy by use of 34 clinical and environmental isolates of Lichtheimia comprising a total of five species. Our data demonstrate that MALDI-TOF MS can be used to clearly discriminate Lichtheimia species from other pathogenic species of the Mucorales. Furthermore, the method is suitable to discriminate species within the genus. The reliability and robustness of the MALDI-TOF-based identification are evidenced by high score values (above 2.3) for the designation to a certain species and by moderate score values (below 2.0) for the discrimination between clinically relevant (Lichtheimia corymbifera, L. ramosa, and L. ornata) and irrelevant (L. hyalospora and L. sphaerocystis) species. In total, all 34 strains were unequivocally identified by MALDI-TOF MS with score values of >1.8 down to the generic level, 32 out of 34 of the Lichtheimia isolates (except CNM-CM 5399 and FSU 10566) were identified accurately with score values of >2 (probable species identification), and 25 of 34 isolates were identified to the species level with score values of >2.3 (highly probable species identification). The MALDI-TOF MS-based method reported here was found to be reproducible and accurate, with low consumable costs and minimal preparation time.  相似文献   