首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Circulating precursor dendritic cells (pDCs) constitute a rare population in peripheral blood. They have a typical immunophenotypic profile, yet, they cannot be identified by pDC-specific immunophenotypic markers and therefore, their accurate and absolute enumeration poses a challenge. Here, we report a method for the evaluation of absolute counts of myeloid pDC in minimally manipulated blood samples on a flow cytometer as a single platform. Three-color flow cytometry was done to identify myeloid pDC as CD33+ HLA-DR+ CD14/CD16(dim/negative) cells in commercially available TruCount trade mark tubes that contain a defined number of brightly fluorescent polystyrene beads. The normal range in peripheral blood of 41 healthy adults, as determined by this single-platform method, was 17.0+/-5.7 x 10(6)/l, or 0.64+/-0.23% of mononuclear cells (MNCs). In parallel experiments, we have compared our procedure with two published 'dual-platform' methods that derive the absolute pDC count from a relative number obtained by flow cytometry, and from absolute counts obtained from a haematological analyser. Regression analysis showed an excellent correlation between results obtained with our single-platform protocol and these double-platform procedures (R2 > or = 0.90). However, the values obtained by the single-platform method were significantly higher than those obtained by the dual-platform methods. The higher myeloid pDC numbers in this single-platform procedure are likely due to reduced cell loss in this 'lyse-no-wash' protocol compared with the other methods which include density gradient separation and centrifugation steps. The intra- and interassay variability were 4.4% (range, 2.04-8.96%) and 5.8% (range, 2.59-9.65%), respectively. Thus, the single-platform method described here allows accurate, rapid and simple measurement of circulating blood myeloid pDC and is suitable for routine enumeration of circulating myeloid pDC.  相似文献   

2.
An accurate and reproducible CD4 count is a fundamental clinical tool for monitoring and treating human immunodeficiency virus infection and its complications. Two methods exist for calculating absolute CD4 counts: dual-platform technology (DPT) and single-platform technology (SPT). Numerous studies have documented the unacceptably wide range of variation in absolute CD4 counts between laboratories. SPT was introduced in 1996 to reduce the interlaboratory variation in absolute CD4 counts. The aim of this study was to compare DPT with the BD Biosciences Trucount method (an SPT method). Both the percentages of CD4 (r = 0.986; P = 0.0541) and the absolute CD4 counts (r = 0.960; P = 0.0001) had very good correlation between the two methods. However, poor correlation was observed for the CD8(+) RO(-) (r = 0.314; P = 0.0002), CD8(+) DR(+) (r = 0.666; P = 0.0138), CD3(+) CD38(+) (r = 0.8000; P = 0.0004), CD3(+) CD25(+) (r = 0.464; P = 0.0082), and CD4(+) CD38(+) (r = 0.357; P = 0.0127) measurements.  相似文献   

3.
New analytic methods that permit absolute CD4 and CD8 T-cell determinations to be performed entirely on the flow cytometer have the potential for improving assay precision and accuracy. In a multisite trial, we compared two different single-platform assay methods with a predicate two-color assay in which the absolute lymphocyte count was derived by conventional hematology. A two-color method employing lymphocyte light scatter gating and Beckman Coulter Flow-Count fluorospheres for absolute counting produced within-laboratory precision equivalent to that of the two-color predicate method, as measured by coefficient of variation of replicate measurements. The fully automated Beckman Coulter tetraONE System four-color assay employing CD45 lymphocyte gating, automated analysis, and absolute counting by fluorospheres resulted in a small but significant improvement in the within-laboratory precision of CD4 and CD8 cell counts and percentages suggesting that the CD45 lymphocyte gating and automated analysis might have contributed to the improved performance. Both the two-color method employing Flow-Count fluorospheres and the four-color tetraONE System provided significant and substantial improvements in between-laboratory precision of absolute counts. In some laboratories, absolute counts obtained by the single-platform methods showed small but consistent differences relative to the predicate method. Comparison of each laboratory's absolute counts with the five-laboratory median value suggested that these differences resulted from a bias in the absolute lymphocyte count obtained from the hematology instrument in some laboratories. These results demonstrate the potential for single-platform assay methods to improve within-laboratory and between-laboratory precision of CD4 and CD8 T-cell determinations compared with conventional assay methods.  相似文献   

4.
New analytic methods that permit absolute CD4 and CD8 T-cell determinations to be performed entirely on the flow cytometer have the potential for improving assay precision and accuracy. In a multisite trial, we compared two different single-platform assay methods with a predicate two-color assay in which the absolute lymphocyte count was derived by conventional hematology. A two-color method employing lymphocyte light scatter gating and Beckman Coulter Flow-Count fluorospheres for absolute counting produced within-laboratory precision equivalent to that of the two-color predicate method, as measured by coefficient of variation of replicate measurements. The fully automated Beckman Coulter tetraONE System four-color assay employing CD45 lymphocyte gating, automated analysis, and absolute counting by fluorospheres resulted in a small but significant improvement in the within-laboratory precision of CD4 and CD8 cell counts and percentages suggesting that the CD45 lymphocyte gating and automated analysis might have contributed to the improved performance. Both the two-color method employing Flow-Count fluorospheres and the four-color tetraONE System provided significant and substantial improvements in between-laboratory precision of absolute counts. In some laboratories, absolute counts obtained by the single-platform methods showed small but consistent differences relative to the predicate method. Comparison of each laboratory's absolute counts with the five-laboratory median value suggested that these differences resulted from a bias in the absolute lymphocyte count obtained from the hematology instrument in some laboratories. These results demonstrate the potential for single-platform assay methods to improve within-laboratory and between-laboratory precision of CD4 and CD8 T-cell determinations compared with conventional assay methods.  相似文献   

5.
With the advent of standard flow cytometric methods using two-colour fluorescence on samples of whole blood, it is possible to establish the ranges of CD3, CD4 and CD8 T lymphocyte subsets in the routine laboratory, and also to assist the definition of HIV-1-related deviations from these normal values. In 676 HIV-1-seronegative individuals the lymphocyte subset percentages and absolute counts were determined. The samples taken mostly in the morning. The groups included heterosexual controls, people with various clotting disorders but without lymphocyte abnormalities as well as seronegative homosexual men as the appropriate controls for the HIV-1-infected groups. The stability of CD4% and CD8% values was demonstrated throughout life, and in children CD4 values less than 25% could be regarded as abnormal. The absolute counts of all T cell subsets decreased from birth until the age of 10 years. In adolescents and adults the absolute numbers (mean +/- s.d.) of lymphocytes, CD3, CD4 and CD8 cells were 1.90 +/- 0.55, 1.45 +/- 0.46, 0.83 +/- 0.29 and 0.56 +/- 0.23 x 10(9)/l, respectively. In patients with haemophilia A and B the mean values did not differ significantly. In homosexual men higher CD8 levels were seen compared with heterosexual men and 27% had an inverted CD4/CD8 ratio but mostly without CD4 lymphopenia (CD4 less than 0.4 x 10(9)/l). However, some healthy uninfected people were 'physiologically' lymphopenic without having inverted CD4/CD8 ratios. When the variations 'within persons' were studied longitudinally over a 5-year period, the absolute CD4 counts tended to be fixed at different levels. As a marked contrast, over 60% of asymptomatic HIV-1+ patients exhibited low CD4 counts less than 0.4 x 10(9)/l together with inverted CD4/CD8 ratios. Such combined changes among the heterosexual and HIV-1-seronegative homosexual groups were as rare as 1.4% and 3%, respectively. For this reason, when the lymphocyte tests show less than 0.4 x 10(9)/l CD4 count and a CD4/CD8 ratio of less than unity, the individuals need to be investigated further for chronicity of this disorder, the signs of viral infections such as HIV-1 and other causes of immunodeficiency.  相似文献   

6.
Flow cytometry is an accurate but expensive method to determine absolute CD4 cell counts. We compared different methods to measure absolute CD4 counts in blood samples from HIV-infected and uninfected subjects using a research/clinical flow cytometer (FACScan); a dedicated clinical instrument (FACSCount); and a volumetric, mobile, open-system flow cytometer equipped with 3 fluorescence and 2 light scatter detectors (Cyflow SL blue). The FACScan and Cyflow were used as single-platform instruments, but they differ in running cost, which is a central factor for resource-poor settings. Direct volumetric and bead-based CD4 measurements on the Cyflow were compared with 2 bead-based single-platform CD4 measurements on the FACSCount and on FACScan (TruCount) in "Le Dantec" Hospital, Dakar, Senegal, using whole blood samples from 102 HIV+ and 28 HIV- subjects. The agreement between the various measurement methods was evaluated by Bland-Altman analysis. Volumetric CD4 measurements on the Cyflow using a no-lyse-no-wash (NLNW) procedure and a lyse-no-wash (LNW) procedure correlated well with each other (R2 = 0.98) and with CD4 measurements on the FACSCount (R2 = 0.97) and FACScan (R2 = 0.97), respectively. Red blood cell lysis had no negative effect on the accuracy of absolute CD4 counting on the Cyflow. An excellent correlation was observed between bead-based CD4 measurements on the Cyflow and CD4 measurements on the FACSCount (R2 = 0.99) and FACScan (R2 = 0.99). Rigid internal and external quality control monitoring and adequate training of technicians were considered essential to generate accurate volumetric CD4 measurements on the Cyflow.  相似文献   

7.
Use of the standard dual-platform flow cytometric method for determination of CD4(+) T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4(+) T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlow(green) (Partec), a single-parameter SP volumetric FCM. The performance of CyFlow(green) was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4(+) and CD8(+) T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlow(green) were compared with those obtained with the bead-based three-color TruCOUNT system (R(2)=0.96; mean bias, -69.1 cells/microl; 95% confidence interval [CI], -225.7 to+87.5 cells/microl) and the FACSCount system (R(2)=0.97; mean bias, -40.0 cells/microl; 95% CI, -165.1 to+85.1 cells/microl). The correlation of the CD4(+) T-lymphocyte counts obtained by the two bead-based systems was high (R(2)=0.98). Interestingly, CyFlow(green) yielded CD4(+) T-lymphocyte counts that were 21.8 and 7.2 cells/microl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4(+) T-lymphocyte counts were <250 CD4(+) T-lymphocyte counts/microl range or 17.3 and 5.8 cells/microl less, respectively, when CD4(+) T-lymphocyte counts were <200 cells/microl. The single-parameter CyFlow(green) volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.  相似文献   

8.
The FACSCount flow cytometer absolute CD3+, CD3+ CD4+, and CD3+ CD8+ cell counts measured at a field site hospital laboratory in Thailand were compared to FACScan absolute counts obtained at a nearby research laboratory. Correlation coefficients for 208 samples were > or = 0.95. The FACSCount was accurate, and it was easier and less expensive to operate than the FACScan. Additionally, the FACScan-generated lymphocyte percentage value was accurate for use with the FACScan SimulSET software.  相似文献   

9.
Relative and absolute neutropenia is frequently seen in the healthy adult Kuwaiti Arab population. Fluorescent monoclonal antibody labelling followed by flow cytometry was used to determine the lymphocyte subsets in 48 normal healthy individuals in the Kuwaiti adult population (24 males and 24 females, age 17-59 years) with relative or absolute neutropenia, and this was compared to age-matched controls (64 males and 63 females). The mean haemoglobin levels were 13.6+/-1.5 and 13.7+/-1.5 g/dl in the neutropenic and control groups, respectively. White blood cell counts, absolute neutrophil and lymphocyte counts in neutropenic individuals with the corresponding reference range, taken from the control subjects (in parenthesis) were: WBC, 6.7+/-1.6 x 10(9)/l (4-10.4 x 10(9)/l), neutrophils, 2.7+/-0.8 x 10(9)/l (1.87-6.63 x 10(9)/l), lymphocytes, 3.3+/-0.9 x 10(9)/l (1.4-3.62 x 10(9)/l). Absolute values of lymphocytes, CD2+, CD3+, CD19+, CD4+, CD8+, HLADR+ and CD45RA+ cells were significantly higher in the neutropenic group. The range of values with the corresponding reference ranges, in parenthesis, were: CD2+, 1.61-4.30 x 10(9)/l (0.95-2.99 x 10(9)/l), CD3+, 1.37-4.16 x 10(9)/l (0.83-2.71 x 10(9)/l), CD19+, 0.16-1.09 x 10(9)/l (0.05-0.61 x 10(9)/l), CD4+, 0.70-2.89 x 10(9)/l (0.45-1.65 x 10(9)/l), CD8+, 0.57-1.80 x 10(9)/l (0.29-1.17 x 10(9)/l), HLADR+ 0.27-1.74 x 10(9)/l (0.02-0.62 x 10(9)/l), CD45RA, 0.90-4.63 x 10(9)/l (0.34-2.05 x 10(9)/l), respectively. The levels of natural killer cells, CD56+ cells were significantly lower compared to controls while the values of memory T lymphocytes, CD45RO+ were comparable to controls. These results indicate that difference in the leukocyte subpopulations may also be indicative of differences in the lymphocyte subpopulations and that reference ranges for these cell types in healthy neutropenic and non-neutropenic individuals should be established.  相似文献   

10.
The study evaluated the single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer (Apogee Flow Systems Ltd., Hemel Hempstead, United Kingdom) for CD4 T cell numeration, compared to the reference FACSCalibur flow cytometer. Results of absolute counts and percentages of CD4 T cells by Auto40 and FACSCalibur of 234 tripotassium EDTA (K3-EDTA)-blood samples from 146 adults and 88 children (aged from 18 months to 5 years), living in Yaoundé, Cameroon, were highly correlated (r2 = 0.97 and r2 = 0.98, respectively). The mean absolute bias and relative bias between Apogee Auto40 and FACSCalibur absolute CD4 T cell counts were +9.6 cells/μl, with limits of agreement from −251 to 270 cells/μl, and +4.1%, with limits of agreement from −16.1 to 24.4%, respectively. The mean absolute bias and relative bias between Apogee Auto40 and FACSCalibur CD4 T cell results expressed as percentages were +0.05% CD4 (95% confidence interval [CI], −0.03 to 0.41), with limits of agreement from −6.0 to 5.9% CD4, and +1.0%, with limits of agreement from −32.3 to 34.4%, respectively. The Auto40 counting allowed identification of the majority of adults with CD4 T cell counts below 200 cells/μl (sensitivity, 87%; specificity, 98%) or below 350 cells/μl (sensitivity, 92%; specificity, 98%) and of children with CD4 T cell counts below 750 cells/μl (sensitivity, 82%; specificity, 98%) or below 25% CD4+ (sensitivity, 96%; specificity, 99%). The Auto40 analyzer is a reliable alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine immunological monitoring according to the WHO recommendations for HIV-infected adults as well as children living in resource-constrained settings.  相似文献   

11.
We studied the relationship of CD4+ and CD8+ depletion to initial and late opportunistic infections in 62 patients with AIDS. The mean interval between initial and late infections was 12.2 months. Geometric mean (and 95% confidence intervals) of T-cell counts at the diagnosis of each infection were: (Pneumocystis carinii pneumonia) CD4+ 0.051 (0.044-0.058) x 10(9)/l, CD8+ 0.561 (0.476-0.646) x 10(9)/l; (cytomegalovirus retinitis) CD4+ 0.025 (0.019-0.031) x 10(9)/l, CD8+ 0.333 (0.183-0.483) x 10(9)/l. Mycobacterium avium-intracellulare bacteraemia closely followed cytomegalovirus dissemination. Most patients were free from late opportunistic infections caused by disseminated cytomegalovirus and M. avium-intracellulare until CD8+ declined below 0.500 x 10(9)/l. Zidovudine improved CD4+, but less so CD8+, and similarly enhanced the survival of patients treated in 1985-1990 and 1991.  相似文献   

12.
A single-platform technology that uses an internal bead standard and three-color flow cytometry to determine CD4 and CD8 absolute counts was evaluated for reproducibility and agreement. Values obtained using TruCount absolute-count tubes were compared to those obtained using a two-color predicate methodology. Sixty specimens from human immunodeficiency virus type 1-infected donors were shipped to five laboratories. Each site also analyzed replicates of 14 human immunodeficiency virus type 1-infected local specimens at 6 h and again at 24 h. The interlaboratory variability was significantly less with TruCount (median difference in percent coefficient of variation [%CV] between the two methods was -8% and -3% for CD4 and CD8, respectively) than with the predicate method. Intralaboratory variability was smaller, with a median difference in %CV of -1% for both CD4 and CD8 with 6-h samples and -2% and -3% for CD4 and CD8, respectively, with 24-h samples. Use of TruCount for shipped samples resulted in a median CD4 count change of 7 cells (50th estimated percentile) when all laboratories and CD4 strata were combined. For on-site samples, the median CD4 count change was 10 CD4 cells for 6-h samples and 2 CD4 cells for 24-h samples. Individual site biases occurred in both directions and cancelled each other when the data were combined for all laboratories. Thus, the combined data showed a smaller change in median CD4 count than what may have occurred at an individual site. In summary, the use of TruCount decreased both the inter- and intralaboratory variability in determining absolute CD4 and CD8 counts.  相似文献   

13.
A survey was carried out on 150 healthy adults to establish hematological reference ranges for human immunodeficiency virus (HIV)-negative adults from the Central African Republic (CAR). Immunohematological mean values, medians, and 95th-percentile reference ranges were established. Mean values were as follows: leukocyte (WBC) counts, 5.28 x 10(9)/liter (males) and 5.11 x 10(9)/liter (females); erythrocyte counts, 5.20 x 10(12)/liter (males) and 4.50 x 10(12)/liter (females); hemoglobin, 15.1 g/dl (males) and 12.5 g/dl (females); hematocrit, 45% (males) and 37% (females); lymphocytes, 2,587/ micro l (males) and 2,466/ micro l (females); CD4 T cells, 927/ micro l (males) and 940/ micro l (females); CD8 T cells, 898/ micro l (males) and 716/ micro l (females); and CD4/CD8 T-cell ratio, 1.13 (males) and 1.41 (females). We concluded that (i) the WBC and hemoglobin values of healthy HIV-negative adults from the CAR are lower than the reference values currently used in the CAR and (ii) the absolute CD4 T-cell counts of healthy HIV-negative adults from the CAR are similar to values for Europeans but the absolute CD8 T-cell counts are much higher. Thus, the CD4/CD8 T-cell ratios for healthy adults from the CAR are significantly reduced compared to the ratios for healthy Europeans.  相似文献   

14.
A single-platform volumetric flow cytometer, the Partec Cyflow SL_3, was evaluated against a BD FACSCalibur/Sysmex XT1800i dual platform for measuring CD4(+) lymphocytes, total lymphocytes, and the percentage of CD4 lymphocytes in whole-blood samples for monitoring the immune systems of human immunodeficiency virus (HIV)/AIDS patients. Statistical analyses for precision, correlation, and agreement were performed. Coefficients of variation (CV) of 5.8, 4.6, and 3.9% were obtained for low, medium, and high CD4(+) cell counts, respectively, using the SL_3, and CV of 3.7, 4.0, and 0.94 were obtained for the same categories, using the BD FACSCalibur. Significant correlations (P < 0.005) between the two assays for CD4 counts, total lymphocyte counts, and percentages of CD4 were obtained, with correlation coefficients of 0.99, 0.96, and 0.99, respectively (n = 229). Using the Bland-Altman plot, mean biases of -18 cell/microl (95% confidence interval (CI); -91 to 54 cells/microl), -0.8% (95% CI; -3.6 to 2%), and -36.8 cells/microl (95% CI; -477 to 404 cells/microl) were obtained for comparisons of CD4 counts, percentages of CD4 cells, and total lymphocyte counts, respectively. The effects of the age of the samples on the three parameters were also analyzed by comparing results from the same samples analyzed at 6, 24, and 48 h after collection. The correlation coefficients for comparisons among different time points for the same machine and among all the time points for the two different machines were greater than 0.90. These data showed that the Partec Cyflow SL_3 assay is comparable to the BD FACSCalibur/Sysmex XT1800i dual-platform method for measuring the amount of CD4(+) cells and total lymphocytes and the percentages of CD4 cells in blood samples for the purpose of monitoring HIV/AIDS patients.  相似文献   

15.
Simplification of cell enumeration technologies is necessary, especially for resource-poor countries, where reliable and affordable enumeration systems are greatly needed. In this paper, an immunomagnetic single-platform image cytometer (SP ICM) for cell enumeration based on antibody specificity is reported. A chamber/magnet assembly was designed such that the immunomagnetically labeled, acridine orange-stained cells in a blood sample moved to the surface of the chamber, where a fluorescent image was captured and analyzed for cell enumeration. The system was evaluated by applying one kind of antibody to count leukocytes and one kind for each leukocyte subpopulation: CD45 for leukocytes, CD3 for T lymphocytes, and CD19 for B lymphocytes. Excellent precision and linearity were achieved. Moreover, these cell counts, each from blood specimens of 42 to 52 randomly selected patients, were compared with those obtained by SP (TruCount) and dual-platform (DP) flow cytometry (FCM) technologies. The cell counts obtained by our system were in between those obtained from the TruCount and DP FCM methods; and good correlations were achieved (R > or = 0.95). For CD4(+) counts, as we expected, the cell count by our system was significantly higher than the CD4(+) T-lymphocyte counts obtained by SP and DP FCM methods. Immunophenotyping of the immunomagnetically selected CD4(+) cells showed that, besides CD4(+) T lymphocytes, a proportion of the CD4(+) dim monocytes was also selected. Our system is a simple immunomagnetic SP ICM, which can potentially be used for enumeration of CD3(+) CD4(+) T lymphocytes in resource-poor countries if an additional CD3 immunofluorescent label is applied.  相似文献   

16.
The flow cytometers that are currently supported by industry provide accurate CD4(+)-T-cell counts for monitoring human immunodeficiency virus disease but remain unaffordable for routine service work under resource-poor conditions. We therefore combined volumetric flow cytometry (measuring absolute lymphocyte counts in unit volumes of blood) and simpler protocols with generic monoclonal antibodies (MAbs) to increase cost efficiency. Volumetric absolute counts were generated using CD45/CD4 and CD45/CD8 MAb combinations in two parallel tubes. The percentage values for the various subsets were also determined within the leukocyte and lymphocyte populations utilizing a fully automated protocol. The levels of agreement between the newly developed method and the present industry standards, including both volumetric and bead-based systems using a full MAb panel for subset analysis, were tested by Bland-Altman analyses. The limits of agreement for CD4 counts generated by the volumetric methods using either CD45/CD4 (in a single tube) or the full Trio MAb panel (in three tubes) on the CytoronAbsolute flow cytometer were between -29 and +46 cells/mm(3) with very little bias for CD4 counts (in favor of the Trio method: +8 CD4(+) lymphocytes/mm(3); 0.38% of lymphocytes). The limits of agreement for absolute CD4 counts yielded by the volumetric CD45/CD4 method and the bead-based method were between -118 and +98 cells/mm(3), again with a negligible bias (-10 CD4(+) lymphocytes/mm(3)). In the volumetric method using CD45/CD8, the strongly CD8(+) cells were gated and the levels of agreement with the full Trio showed a minor bias (in favor of the Trio; +40 CD8(+) cells/mm(3); 5.2% of lymphocytes) without a significant influence on CD4/CD8 ratios. One trained flow cytometrist was able to process 300 to 400 stained tubes per day. This workload extrapolates to a throughput of >30,000 samples per year if both CD45/CD4 and CD45/CD8 stainings are performed for each patient or a throughput of >60,000 samples if only CD45/CD4 counts are tested in a single tube. Thus, on the basis of the high efficiency and excellent agreement with the present industry standards, volumetric flow cytometers with automated gating protocols and autobiosamplers, complemented by generic CD45, CD4, and CD8 MAbs used in two-color immunofluorescence, represent the most suitable arrangements for large regional laboratories in resource-poor settings.  相似文献   

17.
The aim of the study was to follow prospectively the humoral, cellular and innate immune responses under HAART and to verify if a functional restoration of the B lymphocytes could be evaluated by measuring the anti-HIV-1 IgG antibodies avidity index (AI). Eleven HIV-1 infected and immunosuppressed patients were included in the study. Viral load, naive and memory B-cells, CD4 and CD8 T-cells and NK-cells counts, and anti-HIV-1 IgG AI were determined during the follow-up (18 months). Ten patients were sustained responders under HAART and showed a quantitative restoration of the CD4 T-cell counts (+269 x 10(6)/L). The AI decreased for ten subjects (-11%, p = 0.006) but very slowly and continuously. A quantitative restoration of the humoral immune response began, mainly concerning the naive B-cells (+110 x 10(6)/L). Apart from one patient, the CD8 T-cell subset approached the reference values of healthy subjects either by decreasing or increasing their cell levels. No homogeneous evolution was described concerning the NK-cell subset, apart from trend towards increasing in patients with opportunistic infection (range, +58 to +291 x 10(6)/L). Our study, which evaluated simultaneously for the first time to our knowledge the cellular, humoral and innate immune responses showed that HAART induced a large diversity of immune restoration patterns in responder patients. However, the AI measure appears to be a weak marker to evaluate an immune restoration in chronic HIV-1 infected patients under HAART.  相似文献   

18.
After a maximum of 11 years (median 8.3 years) from the time of HIV seroconversion, 25 out of 59 (42%) of CMV-seropositive haemophiliacs had progressed to AIDS, as opposed to eight out of 50 (16%) CMV seronegatives. The age-adjusted relative risk for AIDS among CMV seropositives was 2.4 (P = 0.03). In order to determine how this adverse effect is mediated, the mean rate of decline in serial CD4+ lymphocyte counts was studied. CD4+ lymphocyte counts tended to decline more rapidly in CMV seropositives than in seronegatives (-0.087 x 10(9)/l per annum versus -0.082 x 10(9)/l per annum), but this difference did not reach statistical significance. The average CD4+ lymphocyte count at the time of HIV seroconversion was estimated to be similar in CMV seropositives and negatives, because in HIV-1-negative haemophiliacs the CD4+ counts were virtually identical, after adjustment for age (0.94 x 10(9)/l and 0.97 x 10(9)/l, respectively). The median CD4+ cell count at which AIDS developed was higher in the CMV-seropositive group (0.07 x 10(9)/l) than in the seronegative group (0.04 x 10(9)/l), but this difference did not reach statistical significance. We conclude from these findings that the adverse effect of CMV is not wholly mediated via a more rapid loss of CD4+ cells. We discuss other processes that may be mediated by CMV, such as a functional deficiency of residual CD4+ cells, or dissemination of HIV in other organs, which may be important in determining the earlier onset of AIDS among CMV-seropositive subjects.  相似文献   

19.
Six patients with mantle cell lymphoma, blastoid variant, involving the blood are described. The circulating blast-like cells suggested the possibility of acute leukemias, chronic lymphoproliferative disorders or peripheralized lymphomas. The WBC counts ranged from 3,700 to 249,000/microL (3.7-249.0 x 10(9)/L) and the absolute lymphocyte counts from 1,000 to more than 200,000/microL (1.0 to > 200.0 x 10(9)/L). The peripheral blood smears showed a spectrum of cells, from small mature lymphocytes with irregular nuclei to medium-sized lymphocytes with blast-like chromatin. However, the morphologic features in a lymph node biopsy specimen and the immunophenotype confirmed a diagnosis of mantle cell lymphoma, blastoid variant. By flow cytometry the lymphoma cells expressed B-cell-associated antigens (CD19, CD20 and CD22), coexpressed CD5, lacked CD23, and expressed moderate intensity monoclonal surface immunoglobulin and CD20. Cytogenetic analysis showed the characteristic t(11;14) in 2 of 4 analyzed specimens. Mantle cell lymphoma, blastoid variant, is part of the differential diagnosis for blast-like cells.  相似文献   

20.
Immunohematological reference ranges for adult Ethiopians   总被引:8,自引:0,他引:8  
A cross-sectional survey was carried out with 485 healthy working adult Ethiopians who are participating in a cohort study on the progression of human immunodeficiency virus type 1 (HIV-1) infection to establish hematological reference ranges for adult HIV-negative Ethiopians. In addition, enumeration of absolute numbers and percentages of leukocyte subsets was performed for 142 randomly selected HIV-negative individuals. Immunological results were compared to those of 1,356 healthy HIV-negative Dutch blood donor controls. Immunohematological mean values, medians, and 95th percentile reference ranges were established. Mean values were as follows: leukocyte (WBC) counts, 6.1 x 10(9)/liter (both genders); erythrocyte counts, 5.1 x 10(12)/liter (males) and 4.5 x 10(12)/liter (females); hemoglobin, 16.1 (male) and 14.3 (female) g/dl; hematocrit, 48.3% (male) and 42.0% (female); platelets, 205 x 10(9)/liter (both genders); monocytes, 343/microl; granulocytes, 3, 057/microl; lymphocytes, 1,857/microl; CD4 T cells, 775/microl; CD8 T cells, 747/microl; CD4/CD8 T-cell ratio, 1.2; T cells, 1, 555/microl; B cells, 191/microl; and NK cells, 250/microl. The major conclusions follow. (i) The WBC and platelet values of healthy HIV-negative Ethiopians are lower than the adopted reference values of Ethiopia. (ii) The absolute CD4 T-cell counts of healthy HIV-negative Ethiopians are considerably lower than those of the Dutch controls, while the opposite is true for the absolute CD8 T-cell counts. This results in a significantly reduced CD4/CD8 T-cell ratio for healthy Ethiopians, compared to the ratio for Dutch controls.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号