BackgroundTotal hip arthroplasty (THA) performed for developmental dysplasia of the hip is a technically difficult procedure with a high complication rate, especially in the presence of completely dislocated hips. This study aimed to evaluate at least 10 years of follow-up results of cementless, ceramic-on-ceramic (CoC) THA performed with transverse subtrochanteric osteotomy in Crowe type IV hips.MethodsWe retrospectively reviewed 50 patients’ 67 hips that underwent CoC, cementless THA with transverse subtrochanteric osteotomy between 2008 and 2011. Clinical and radiological data of the hips were examined. Clinical results were evaluated using the Harris Hip Score and the Western Ontario and McMaster Universities Osteoarthritis Index.ResultsThe mean Harris Hip Score improved from 22.9 ± 9.9 preoperatively to 94.1 ± 8.1 at the final follow-up (P < 0.001). The median Western Ontario and McMaster Universities Osteoarthritis Index score improved from 72 (interquartile range: 17) preoperatively to 2 (interquartile range: 17) postoperatively (P < 0.001). The preoperative mean leg length discrepancy was improved from 4.9 ± 1 cm to 1.5 ± 1 cm in unilateral cases at the last follow-up (P < 0.001). Revision surgery was required because of nonunion in two patients, prosthetic infection in one patient, and aseptic femoral loosening in the other patient. The overall ten-year survival rate was 94% for femoral stems and 98.5% for acetabular components as per Kaplan-Meier survival analysis.ConclusionTransverse subtrochanteric shortening osteotomy combined with using cementless acetabular and femoral components with a CoC bearing surface promises successful clinical results and high prosthesis survival in the treatment of Crowe IV hips at long-term follow-up.  相似文献   

2.
《The Journal of arthroplasty》2022,37(10):2053-2062
BackgroundDifferent bearings have been used in total hip arthroplasty (THA), but the long-term performance is still controversial. The purpose of this study was to investigate whether there are differences when comparing THAs with 5 different bearings at a long-term follow-up of more than 10 years.MethodsFrom January 2010 to May 2012, 101 THA patients (134 hips) were divided into metal-on-metal group (MoM, 31 hips), metal-on-polyethylene group (MoP, 23 hips), ceramic-on-metal group (CoM, 21 hips), ceramic-on-ceramic group (CoC, 33 hips), and ceramic-on-polyethylene group (CoP, 26 hips). The mean follow-up period was 10.3 years. The Harris hip score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index scores (WOMAC), range of motion (ROM), blood cell count, and liver-kidney function were measured. Serum and urine metal ion levels were measured using high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) and a blood lymphocytes analysis was counted by flow cytometry.ResultsNo difference was observed in the HSS, WOMAC, ROM, blood cell count, or liver-kidney function among any of the 5 groups. Metal ion levels were significantly elevated in metal-containing bearings. Flow cytometry showed that no differences were found. Revision was performed due to pseudotumor in 3 patients. The implant survival rate was 96.7% and 93.3% for the MoM and CoC groups, which was significantly lower compared with other groups.ConclusionsMetal ion levels were elevated significantly in metal-containing bearings, especially in MoM THA patients. The implant survival rate was significantly lower in CoC and MoM THAs, which was mainly due to pseudotumor formation.Level of EvidenceTherapeutic Level II.  相似文献   

3.
Background and purpose — Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA.

Patients and methods — In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk.

Results — 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72–2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p < 0.001). 6 patients with CoC bearings (0.34%) underwent revision due to ceramic fracture.

Interpretation — When compared to the “standard” MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years.  相似文献   

4.
《The Journal of arthroplasty》2023,38(8):1539-1544
BackgroundThere are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA.MethodsAmong the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up.ResultsSurvivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification.ConclusionThis CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.  相似文献   

5.

Background

There are limited studies to evaluate long-term clinical and radiographic outcomes of alumina delta ceramic-on-ceramic bearings in cementless total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiographic results, prevalence of osteolysis, squeaking, and fracture of ceramic material associated with the use of the alumina delta ceramic-on-alumina delta ceramic bearing in cementless THA in patients aged <50 years.

Methods

We reviewed the cases of 277 patients (334 hips) who underwent a cementless THA using alumina delta ceramic-on-alumina delta ceramic when they were 50 years or younger at the time of surgery. Demographic data; Harris Hip Score; Western Ontario McMaster Universities Osteoarthritis Index; and University of California, Los Angeles activity score were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. Squeaking sound and ceramic fracture were documented. The mean follow-up was 7.8 years (range, 6-9).

Results

The mean postoperative Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 93 points, 15 points, and 8.6 points, respectively. Two patients had thigh pain (grade 7 points). All acetabular components and all but 2 femoral components were well fixed. Thirty-three hips (10%) exhibited clicking sound, and 2 hips (0.6%) exhibited squeaking sound. No hip had osteolysis or ceramic head or liner fracture.

Conclusion

Our minimum 6-year follow-up results with the use of alumina delta ceramic-on-alumina delta ceramic bearings in patients aged <50 years suggest that cementless THA provides a high rate of survivorship without evidence of osteolysis or fracture of ceramic material.  相似文献   

6.
BackgroundMetal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has recently gained increased utilization as a screening modality in patients with a total hip arthroplasty (THA). Fluid collections have been documented in asymptomatic patients with various bearing surfaces. The purpose of this study is to determine the frequency and types of MARS MRI-documented abnormalities in asymptomatic patients with a ceramic-on-ceramic (CoC) THA.MethodsThirty-seven patients (42 hips) with a minimum 2-year follow-up after THA with CoC THA implants were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a MARS MRI. Abnormalities were documented using a previously described method.ResultsFluid collections were observed in 8 (19%) asymptomatic hips in this cohort. Four of the 8 hips demonstrated intracapsular synovitis, and 3 of these hips had a thickened synovium. Extra-articular fluid collections with direct intra-articular communication were identified in 4 hips, with 2 of these hips demonstrating synovial thickening. No signs of osteolysis were noted on radiographs or the MARS MRI scans.ConclusionAsymptomatic fluid collections occur in patients after CoC THA similar to other bearing surfaces. We continue to follow these patients in an effort to determine the clinical significance and natural history of these findings.Level of EvidenceDiagnostic Level IV.  相似文献   

7.
This study examined long-term survivorship of primary total hip arthroplasty (THA) using cementless Harris-Galante porous femoral and Harris-Galante porous I or II acetabular components. Of 113 hips (101 patients) studied, 60 hips (53 patients) were available for follow-up at a mean of 17.2 years after surgery. A total of 10 hips had documented revision, and 2 hips had failed radiographically. The average Harris hip score was 82. Radiographically, 12 hips demonstrated eccentric wear, 8 had osteolysis, and 1 had a broken tine. The overall survival rate was 87.7%; the mean volumetric wear rate was 74.96 mm3; and the mean polyethylene linear penetration rate was 0.153 mm/y, similar to that of well-cemented THA in other series. This long-term outcome for an early-generation cementless THA is promising and provides a standard by which to judge the newer generation of cementless implants.  相似文献   

8.
BackgroundWe aimed to make comparisons of different bearing surfaces in patients after cementless total hip arthroplasty.MethodsThe network meta-analysis was guided by the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guideline. The primary outcomes were implant survival and Harris hip score (HHS). Secondary outcomes included linear wear rates and serum level of metal ions. Subgroup analyses were performed by: (1) classifying head sizes as small and large; (2) femoral heads as ceramic and metal; and (3) liners as metal, ceramic, polyethylene, highly cross-linked polyethylene (HXP), or vitamin E-infused highly cross-linked polyethylene (HXPE). A total of 64 eligible RCTs with different bearings were assessed. Overall inconsistency and heterogeneity were acceptable.ResultsIn the 10 years follow-up, metal-on-polythene and ceramic-on-polythene bearings with small heads showed higher risk for revisions compared with metal-on-HXP and ceramic-on-HXP bearings with small heads. Similarly, only metal or ceramic-on-polythene bearings with small heads showed inferiority in HHS compared with other bearings. Conventional polyethylene liners showed higher linear wear rates compared with HXP, HXPE, and ceramic liners at 5 and 10 years after surgery, while metal-on-metal and ceramic-on-metal bearings showed higher serum level of cobalt and chromium.ConclusionBearings containing HXP, HXPE, and ceramic liners showed comparable survivorship and hip function at follow-up of 5 and 10 years. Hard-on-hard bearings containing metal had higher serum level of metal ions than others. Bearings containing conventional polyethylene had worse performance in terms of implant survival, hip function, and wear rates.Level of EvidenceLevel I.  相似文献   

9.
《The Journal of arthroplasty》2020,35(10):2911-2918
BackgroundTotal hip arthroplasty (THA) of patients with a proximal femoral deformity is technically demanding. This deformity poses the risk of femoral fracture or perforation; stem malposition; and failed stem fixation. To insert a femoral stem in neutral position with a good fit, we removed the greater trochanter in case of a varus deformity, and the lesser trochanter in case of valgus deformity, while performing THA. We aimed to evaluate stem position, implant stability, clinical results, and radiological changes after THAs using this technique.MethodsFifteen patients (17 hips; 11 varus hips and 6 valgus hips) underwent cementless THA using the trochanteric osteotomy technique in one institution. We evaluated procedure-specific complications: intraoperative femoral fracture, stem malposition, weakness of the abductor power and limp. Modified Harris Hip Score, radiological changes, and the stability of stems were assessed at a mean of 7.1 years of follow-up (range 2.0-15.5).ResultsFemoral fracture occurred during the insertion of the stem in 4 hips. All stems were aligned in neutral position. At the latest follow-up, the mean power of the abductor was 4.3 (range 3-5). Eleven patients had slight limp and 4 patients had moderate limp. All stems had bone-ingrown stability and no stem was revised. The mean modified Harris Hip Score improved from 50 points at the preoperative evaluation to 81 points at the final follow-up.ConclusionThe trochanteric excision enabled neutral insertion of cementless stem in patients with varus/valgus deformity of the proximal femur, and THA using this technique rendered favorable results.  相似文献   

10.
BackgroundTo report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL).MethodsFrom a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors.ResultsThe 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030).ConclusionOf 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.  相似文献   

11.
《The Journal of arthroplasty》2019,34(7):1435-1440
BackgroundThe purpose of this study was to identify reasons for revision of total hip arthroplasty (THA) in patients who underwent primary THA at or before the age of 35 years. We hypothesized that the reasons for revision in younger patients would be different from the general older population of patients undergoing THA because of the differences in diagnoses, complexity of deformities, and differences in activity level.MethodsData for 108 hips in 82 patients who underwent primary THA at our institution before the age of 35 years from 1982-2007 and subsequently underwent revision THA were reviewed. Operative reports and clinic notes were reviewed to determine baseline characteristics, reason for revision, timing of revision, and components revised.ResultsThe mean age at index surgery was 25.4 years, and mean time from index to revision surgery was 10.1 years. The most common preoperative diagnoses included avascular necrosis, juvenile idiopathic arthritis, developmental dysplasia of the hip, and posttraumatic arthritis. The most common reasons for revision were acetabular loosening (30.1%), femoral loosening (23.7%), and polyethylene wear (24.7%). 8.3% of patients underwent primary THA with highly cross-linked polyethylene, while the remainder of the patients underwent THA when conventional polyethylene was used. There was no statistically significant association between which component(s) were revised and initial fixation (ie cemented or uncemented prosthesis) (P = .26).ConclusionCauses of revision in this population appear to differ from the general THA population. In young patients, acetabular loosening, femur loosening, and polyethylene wear were the most common causes of revision. Instability and infection were less common compared with literature reports of causes of revision in older patients. Findings in this study may be useful in counseling young patients undergoing THA, though results were likely influenced by the use of conventional rather than highly cross-linked polyethylene in this cohort.  相似文献   

12.
Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear. The aim of the present study was to evaluate the long-term results of a series of Metasul (Zimmer GmbH, Winterthur, Switzerland) metal-on-metal total hip arthroplasty (THA). One hundred forty-nine cementless THAs with a 28-mm Metasul articulation were performed in 111 consecutive patients. The results were retrospectively reviewed at 13 years postoperatively. Clinical and radiographic evaluations and implant survivorship were performed. Seven hips (4.7%) were revised. The overall survivorship with revision for any reason as the end point was 0.94. The average Harris hip score was 91.4. Expansive osteolysis was found adjacent to the stem in 4 hips. Metal wear-related aseptic loosening was not the major reason for failure in our Metasul metal-on-metal THAs. Recurrent dislocation was the main reason for revision in our series.  相似文献   

13.
BackgroundAlumina ceramic-on-ceramic bearings are used in total hip arthroplasty (THA) because of their wear-resistant and inert properties. In this study, we assessed the clinical and radiographic outcomes of patients undergoing primary cementless ceramic-on-ceramic THA at a minimum follow-up of 20 years.MethodsA series of 301 consecutive primary THAs in 283 patients were assessed. Clinically, patients were assessed with the modified Harris Hip Score (HHS) and pain questionnaires. Anteroposterior radiographs of the pelvis and lateral radiographs of the hip were used to radiologically assess the implant. Patients were classified as lost to follow-up if they could not be contacted on multiple occasions or did not wish to participate further in this study.ResultsAt twenty years after operation, 60 patients had died of a cause unrelated to surgery, 16 had experienced complications requiring reoperation, and 100 hips had both clinical assessments and radiographs at a minimum of 20 years of follow-up. The average HHS improved from 56.1 (range: 17-89) before THA to 92.5 (range: 63-100) at the latest follow-up. The classification of the HHS was good or excellent in 96.4% of patients. Only 1.8% of patients still had moderate residual pain at the thigh or groin. Radiographically, all patients demonstrated bony ingrowth but no clinical symptoms of loosening. The overall survival rate of the implants was 94.2% at 20 years with revision for any reason as the end point.ConclusionLong-Term follow-up in our series showed excellent implant survival, excellent functional outcomes, and minimal late complications. There was no significant radiographic evidence of failure at a minimum of 20 years after THA.Level of evidenceTherapeutic Level IV.  相似文献   

14.
《The Journal of arthroplasty》2021,36(10):3498-3506
BackgroundProsthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings.MethodsAdult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data.ResultsIn total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001)ConclusionThis study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.  相似文献   

15.
《The Journal of arthroplasty》2020,35(7):1885-1890
BackgroundThe aim of this study is to evaluate midterm clinical and radiographic results of total hip arthroplasties (THAs) with cementless implants for adult patients with sequelae from childhood hip infection.MethodsBetween 2002 and 2016, 165 patients (165 hips) who had a hip infection during childhood were treated with THAs with cementless implants. The average duration of follow-up was 93.5 months (range 26-206). Clinical results were evaluated via the Harris Hip Score and radiographic results were analyzed with postoperative serial X-rays.ResultsThe average Harris Hip Score increased from 27 (range 8-53) before surgery to 91 (range 45-100) at the latest follow-up examination (P < .001). At the latest follow-up evaluation, 9 cementless acetabular components demonstrated partial, nonprogressive radiolucencies. No subsidence of more than 2 mm or evidence of a radiolucent line was observed around the femoral components. Intraoperative periprosthetic fractures occurred in 11 hips, including 3 acetabular fractures, 2 fractures of greater trochanter, 1 femoral shaft fracture, and 5 fractures of femoral calcar. Postoperative complications included 3 cases of periprosthetic infection, 1 episode of dislocation, 1 case of a femoral periprosthetic fracture, 5 cases of sciatic nerve injury, 1 case of femoral nerve injury, and 1 case of squeaking from a ceramic bearing surface.ConclusionCementless THA for adult patients with sequelae from childhood hip infection presents significant technical challenges and a relatively high complication rate. With meticulous surgical planning and anticipation for the key technical challenges frequently encountered, the medium-term clinical and radiographic results of THA in this setting were good with high implant survivorship and patient satisfaction.  相似文献   

16.
BackgroundThe rate of failure of cemented and cementless total hip arthroplasty (THA) in younger patients is higher than that in elderly patients. The purpose of this study is to document the long-term clinical results of THA with the so-called third-generation cementing and the results of second-generation cementless THA in patients <50 years of age.MethodsThis study included 106 patients who had had bilateral THA with a cemented stem in one hip and a cementless stem in the other. There were 78 men and 28 women. Their mean age was 47 years (range, 21-49). The average follow-up duration was 31 years (range, 30-32.5).ResultsThere were similar mean Harris Hip Scores (90 versus 91 points) between the groups at the final follow-up. Forty-six acetabular components (43%) in the cemented group and 48 acetabular components (45%) in the cementless group were revised. Five femoral components (5%) in the cemented group and 4 femoral components (4%) in the cementless group were revised. Survivorship of the acetabular component at 30.8 years was similar in both groups (57% in the cemented group versus 55% in the cementless group). Survivorship of the femoral component at 30.8 years was also similar in both groups (95% in the cemented group versus 96% in the cementless group).ConclusionLong-term fixation of the cemented or cementless femoral stem was outstanding. There was a high rate of the acetabular component revision due to conventional polyethylene wear and periacetabular osteolysis in both hybrid and fully cementless THA groups.  相似文献   

17.
目的探讨应用LCU股骨柄假体行生物学固定型全髋关节置换术(total hip arthroplasty,THA)的早期疗效。方法回顾性分析2011年8月至2013年4月采用LCU股骨柄假体行THA术85例(90髋),男26例(28髋),女59例(62髋);年龄19~83岁,平均55岁;平均体重指数(23.33±3.13)kg/m2。单髋80例,双髋5例。发育性髋关节发育不良34例(38髋),股骨颈骨折14例(14髋),股骨头坏死17例(17髋),原发性髋关节骨关节炎18例(19髋),类风湿性髋关节炎1例(1髋),髋关节结核1例(1髋)。股骨侧假体均采用LCU股骨柄假体。髋臼采用陶瓷-陶瓷界面者78髋,陶瓷-聚乙烯12髋。对术后及随访时的影像学资料进行分析,末次随访时采用髋关节Harris评分标准评定疗效。结果 82例(87髋)患者术后获得随访,随访12~32个月,平均19个月,3例失访。术前髋关节功能Harris评分为(33.73±3.21)分,末次随访时髋关节功能Harris评分改善至(92.84±4.47)分,与术前比较差异有统计学意义(t=242.69,P0.01)。末次随访时大腿轻度疼痛1例,中度疼痛1例,无重度疼痛。末次随访时无一例出现骨溶解、假体松动,按Engh标准评定:所有获访者均获骨长入固定,其中股骨侧假体诊断为骨性固定者85髋,诊断为纤维性稳定者1髋。假体下沉小于2 mm者1髋,其余均无假体下沉。结论 LCU股骨柄假体行生物学固定型THA的早期疗效满意。  相似文献   

18.

Background

Dislocation is a leading cause of revision after primary total hip arthroplasty (THA). Although more common in the first few years after the procedure, dislocation can occur at any time. This study investigated the difference in late dislocation in ceramic-on-ceramic (CoC) bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings in THA.

Methods

Data were used from the Australian Orthopaedic Association National Joint Replacement Registry, and the cumulative percent revision for dislocation was estimated using the Kaplan-Meier method for the different bearing surfaces. There were 192,275 THAs included in the study with 101,915 metal-on–cross-linked polyethylene (MoXLPE), 30,256 ceramic-on–cross-linked polyethylene (CoXLPE), and 60,104 CoC.

Results

The cumulative percent revision for dislocation at 13 years for MoXLPE, CoXLPE, and CoC groups was 1.2 (95% confidence interval [CI], 1.1-1.3), 1.0 (95% CI, 0.7-1.4), and 0.9 (95% CI, 0.8-1.1), respectively. There was an increased risk of revision for dislocation for MoXLPE compared with CoXLPE and CoC. When stratified for head size, there was no difference in the risk of revision for dislocation between MoXLPE, CoXLPE, and CoC in the 28- and 32-mm head sizes. With a head size of 36 mm, MoXLPE had a higher rate of dislocation compared with other materials.

Conclusion

Bearing surface has little impact on revision for dislocation.  相似文献   

19.

Background

In the early days when delta ceramics were developed, there was a period of using delta ceramic liner and alumina ceramic head. Therefore, the purpose of this study is to investigate the clinical and radiological outcomes of total hip arthroplasty using delta ceramic liner on alumina ceramic head after a minimum of 10 years of follow-up and to evaluate problems of early delta ceramic liner.

Methods

Alumina on delta cementless total hip arthroplasty was performed in 92 hips (85 patients) from August 2005 to March 2007 at our hospital. Bilateral total hip arthroplasty were performed in 7 patients, 30 patients on the left side and 48 patients on the right side. Preoperative diagnosis was osteonecrosis of the femoral head in 34 hips (37%), degenerative arthritis in 31 hips (33.7%), femur neck fracture in 21 hips (22.8%), and rheumatoid arthritis in 6 hips (6.5%). All surgeries were carried out with anterolateral approach. For the clinical evaluation, Harris hip score (HHS), pain, and range of motion were assessed. Radiographs were reviewed by the authors to search for any signs of osteolysis, loosening of implants, and heterotopic ossification.

Results

HHS was compared between preoperative and final follow-ups. The mean HHS improved from preoperative 58.3 points (range 27-76) to 92.7 points (range 78-98) on the final follow-up (P = .02). The mean range of hip motion at the final follow-up was flexion 116.9°, adduction 23.8°, abduction 34.6°, internal rotation 16.3°, and external rotation 39.2°. As for the postoperative pain, 1 patient complained of inguinal pain and 4 patients complained of thigh pain. Because of trauma, 3 cases of dislocation were observed in all cases. There are 3 cases with dislocation and 2 cases were treated with conservative treatment without recurrence, but 1 case was required for surgical treatment due to eccentric rim wear of delta liner. The aseptic loosening of acetabular cup and femoral stem was each 1 hip.

Conclusion

Alumina head-on-delta liner cementless THA, using a large femoral head 32-36 mm in diameter, demonstrated satisfactory clinical and radiological results in the minimum 10 years of follow-up. Eccentric rim wear can occur even in delta ceramic liners that are known to have high strength, and this can lead to dislocation which can, in turn, increase the possibility of linear fracture.  相似文献   

20.
Seventy-nine patients (94 hips), who underwent cementless alumina-on-alumina total hip arthroplasty (THA) with the use of a 36-mm delta ceramic liner-on-alumina ceramic femoral head, were followed for an average of 6.5 years (range, 5–7.7 years). All acetabular and femoral components were bone-ingrown and neither pelvic nor femoral osteolysis was identified until the latest follow-up. The survivorship with revision surgery as an endpoint was 97.9% (95% confidence interval = 100%–95%). Ceramic related complications such as fracture and squeaking did not occur in any patient. The mid-term results of cementless THA with this type of ceramic articulation are encouraging.  相似文献   