首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
《Value in health》2021,24(12):1799-1806
ObjectivesThe study aimed to assess the reliability and validity of EQ-5D-5L-Y and to compare the performance of EQ-5D-5L-Y with EQ-5D-3L-Y in children and adolescents.MethodsThe Spanish versions of the 3L and 5L of EQ-5D for youths, were administered to children and adolescents from the general population. Feasibility and reliability were determined for the EQ-5D-5L-Y. The EQ-5D-5L-Y and EQ-5D-3L-Y were evaluated in terms of ceiling effects, informativity, and correlations with other generic measurements of health-related quality of life.ResultsA total of 714 healthy children and adolescents (10.7 ± 2.1 years old) from the general population participated in the study. Most of the sample reported full health status. The feasibility and reliability for the EQ-5D-5L-Y were acceptable, but the questionnaire showed a low convergent validity. Absolute informativity (Shannon index) showed a slight increase in all dimensions of the 5L compared with the 3L; nevertheless, there were only statistically significant differences between 5L and 3L in the dimension “feeling worried, sad, or unhappy” and also on the overall system. Relative informativity (Shannon evenness index) showed a decrease in the 5L compared with 3L for all dimensions, except for “looking after myself.” Correlations with other health measurements, in both 3L and 5L, showed similar results to those observed in the international EQ-5D-3L-Y validation study.ConclusionThe results show that EQ-5D-5L-Y is feasible, consistent, and reliable, but there are minor differences in the ceiling effect and informativity between the EQ-5D-5L-Y and EQ-5D-3L-Y versions in the general population.  相似文献   

3.
ObjectivesThis study evaluated the validity and reliability of the Health-Related Quality of Life Instrument with 8 Items (HINT-8) in postoperative breast cancer patients in South Korea.MethodsThe study included 300 breast cancer patients visiting a tertiary hospital. We measured health-related quality of life (HRQoL) using the HINT-8, the 5-level EQ-5D version (EQ-5D-5L), and the Functional Assessment of Cancer Therapy-Breast (FACT-B). Discriminatory ability, known-group validity, and convergent validity were assessed. Reliability was evaluated with the Cohen kappa, weighted kappa, and intraclass correlation coefficient (ICC).ResultsThe EQ-5D-5L indexes (p<0.001) and EQ visual analogue scale (VAS) scores (p<0.001) were significantly higher in subjects with no problems in each item of the HINT-8 than in those with problems. The FACT-B total scores were also higher in subjects without problems on the HINT-8. Older age, lower education level, and comorbidities were associated with a lower HINT-8 index. The HINT-8 index was correlated with the EQ-5D-5L index and the EQ VAS, with correlation coefficients of 0.671 (p<0.001) and 0.577 (p<0.001), respectively. The correlation coefficients between the HINT-8 and the FACT-B ranged from 0.390 to 0.714. The ICC was 0.690 (95% confidence interval, 0.580–0.780).ConclusionThe HINT-8 showed appropriate validity for capturing HRQoL in postoperative breast cancer patients.  相似文献   

4.

Purpose

This study was conducted to assess the redistribution properties of the EQ-5D-3L when using the EQ-5D-5L and to compare the validity, informativity, and reliability of both EQ-5D-3L and EQ-5D-5L in Korean cancer patients.

Methods

Patients visiting one ambulatory cancer center self-administered the two versions of the EQ-5D and the EORTC QLQ-C30 questionnaire. Redistribution properties in each dimension of EQ-5D were analyzed between EQ-5D-3L and EQ-5D-5L. Informativity was evaluated using the Shannon entropy and ceiling effect. Convergent validity was evaluated by comparing the EQ-VAS, ECOG performance status, and EORTC QLQ-C30 subscales. Reliability was also evaluated in terms of test?Cretest reliability.

Results

All levels of the EQ-5D-3L substantially partitioned into associated levels of the EQ-5D-5L. The average inconsistency rate of the two versions was 3.5%. Absolute informativity was higher for the EQ-5D-5L than for the EQ-5D-3L, but their informative efficiency tended to be similar. The proportion of ??perfect health?? (11111) decreased from 16.8% in the EQ-5D-3L to 9.7% in the EQ-5D-5L. EQ-5D-5L demonstrated similar or higher correlations with the EQ-VAS, ECOG performance status, and EORTC QLQ-C30, than the EQ-5D-3L. The intraclass correlation coefficient of the EQ-5D-5L index was 0.77.

Conclusions

The EQ-5D-5L had greater informativity and lower rate in the ceiling effect than those values of the EQ-5D-3L. The EQ-5D-5L showed good construct validity and reasonable reliability. Therefore, considering these findings, the EQ-5D-5L may be preferable to the EQ-5D-3L.  相似文献   

5.
6.
Toh  Hui Jin  Yap  Philip  Wee  Shiou Liang  Koh  Gerald  Luo  Nan 《Quality of life research》2021,30(3):713-720
Objective

Our study examined the feasibility and validity of the EQ-5D-5L proxy questionnaire in measuring health-related quality of life (HRQoL) of nursing home residents.

Methods

Twenty-four nurses and 229 residents from 3 nursing homes in Singapore participated in this cross-sectional study. Nurses assessed residents under their care with the EQ-5D-5L proxy questionnaire. Two experienced mappers conducted Dementia Care Mapping (DCM) within 1 month in a subsample of the residents. Feasibility was evaluated according to percentage of unanswered EQ-5D-5L items and proportion of nurses who failed to respond to all items. Convergent validity was assessed by examining the correlation between EQ-5D-5L measures and DCM scores. Known-groups validity was assessed by comparing differences in EQ-5D-5L scores for residents with varying communication abilities and physical functions.

Results

The nurses’ mean age was 35.4 years while the residents’ was 73.4 years. Most residents were female (51.3%) and had the ability to communicate (81.3%). For 6 of the 229 residents (2.6%), not all items in the EQ-5D-5L were completed. The EQ-5D-5L index score correlated positively and moderately with the DCM’s well/ill-being score (r?=?0.433, n?=?90, P?<?0.01). Residents who were able to communicate effectively or had better physical function were assessed to have less severe health problems and better EQ-5D-5L scores.

Conclusion

The EQ-5D-5L proxy questionnaire has adequate feasibility and validity when used by nurses to assess the HRQoL of nursing home residents. As it is brief and can be conveniently administered, it can be deployed on a larger scale to assess HRQoL of nursing home residents.

  相似文献   

7.
8.
《Value in health》2021,24(8):1223-1233
ObjectivesThis study aimed to synthesize and evaluate published evidence on the measurement properties of the EQ VAS, a component of all EQ-5D questionnaires.MethodsThis systematic review followed the Consensus-Based Standards for the Selection of Health Measurement Instruments guidelines. Five electronic databases were searched for EQ-5D-3L and EQ-5D-5L validation articles published from January 1, 2009, to November 5, 2019. Evidence for construct validity, test–retest reliability, and responsiveness was extracted from individual studies before being aggregated for evaluation of the populations represented by the studied samples. Multivariable logistic meta-regression was conducted to explore the effects of potential covariates on construct validity.ResultsA total of 50 articles containing 488 studies, using samples drawn from 12 different populations, were identified. Generally, the quality of evidence was high for construct validity studies (n = 397) but only moderate for both test–retest reliability studies (n = 21) and responsiveness studies (n = 70). “Sufficient” construct validity of EQ VAS was found in 8 of 12 populations, “sufficient” test–retest reliability was found in 3 of 11 populations, and “sufficient” responsiveness was found in 5 of 12 populations. Meta-regression analyses suggested that construct validity studies from the Asian-Pacific region were more likely to show a negative rating compared with studies from Europe and North America.ConclusionThe EQ VAS exhibits “sufficient” construct validity, “inconsistent” test–retest reliability, and “inconsistent” responsiveness across a broad range of populations. Additional studies are needed to explore the suboptimal validity of the EQ VAS in the Asian-Pacific region, whereas more high-quality validation studies are needed to assess its reliability and responsiveness.  相似文献   

9.

Purpose

Generic preference-based quality of life (PbQoL) measures are sometimes criticized for being insensitive or failing to capture important aspects of quality of life (QoL) in specific populations. The objective of this study was to systematically review and assess the construct validity and responsiveness of PbQoL measures in Parkinson’s.

Methods

Ten databases were systematically searched up to July 2015. Studies were included if a PbQoL instrument along with a common Parkinson’s clinical or QoL measure was used, and the utility values were reported. The PbQoL instruments were assessed for construct validity (discriminant and convergent validity) and responsiveness.

Results

Twenty-three of 2758 studies were included, of which the majority evidence was for EQ-5D. Overall good evidence of discriminant validity was demonstrated in the Health Utility Index (HUI)-3, EQ-5D-5L, EQ-5D-3L, 15D, HUI-2, and Disability and Distress Index (DDI). Nevertheless, HUI-2 and EQ-5D-3L were shown to be less sensitive among patients with mild Parkinson’s. Moderate to strong correlations were shown between the PbQoL measures (EQ-5D-3L, EQ-5D-5L, 15D, DDI, and HUI-II) and Parkinson’s-specific measures. Twelve studies provided evidence for the assessment of responsiveness of EQ-5D-3L and one study for 15D, among which six studies reached inconsistent results between EQ-5D-3L and the Parkinson’s-specific measures in measuring the change overtime.

Conclusions

The construct validity of the PbQoL measures was generally good, but there are concerns regarding their responsiveness to change. In Parkinson’s, the inclusion of a Parkinson’s-specific QoL measure or a generic but broader scoped mental and well-being focused measure to incorporate aspects not included in the common PbQoL measures is recommended.
  相似文献   

10.
Background

Atopic dermatitis (AD) is a common chronic inflammatory skin disorder affecting up to 10% of adults. The EQ-5D is the most commonly used generic preference-accompanied measure to generate quality-adjusted life years (QALYs) for economic evaluations.

Objectives

We aimed to compare psychometric properties of the three-level and five-level EQ-5D (EQ-5D-3L and EQ-5D-5L) in adult patients with AD.

Methods

In a multicentre cross-sectional study, 218 AD patients with a broad range of severity completed the EQ-5D-3L, EQ-5D-5L, Dermatology Life Quality Index (DLQI) and Skindex-16. Disease severity outcomes included the Investigator Global Assessment, Eczema Area and Severity Index and the objective SCORing Atopic Dermatitis.

Results

A good agreement was established between the two EQ-5D versions with an intraclass correlation coefficient of 0.815 (95% CI 0.758–0.859, p < 0.001). Overall, 33 different health state profiles occurred in the EQ-5D-3L and 84 in the EQ-5D-5L. Compared to the EQ-5D-3L, ceiling effect was reduced for the mobility, self-care, usual activities and pain/discomfort dimensions by 4.6–11.5%. EQ-5D-5L showed higher average relative informativity (Shannon’s evenness index: 0.64 vs. 0.59). EQ-5D-5L demonstrated better convergent validity with EQ VAS, DLQI and Skindex-16. The two measures were similar in distinguishing between groups of patients based on disease severity and skin-specific quality of life with a moderate or large effect size (η2 = 0.083–0.489).

Conclusion

Both instruments exhibited good psychometric properties in AD; however, the EQ-5D-5L was superior in terms of ceiling effects, informativity and convergent validity. We recommend the use of the EQ-5D-5L to measure health outcomes in clinical settings and for QALY calculations in AD.

  相似文献   

11.

Background

Limited health care budgets and population aging result in a need to compare care services on their benefits and costs. Because services for older people often aim to improve multiple life aspects, valid measures are needed to examine their benefits on individuals’ health and well-being simultaneously. Two measures may meet this end: the Adult Social Care Outcomes Toolkit (ASCOT) and the ICEpop CAPability measure for Older people (ICECAP-O).

Objectives

To compare the validity of both measures, the ASCOT and the ICECAP-O.

Methods

A sampling agency gathered cross-sectional data in May 2015. Using exploratory factor analysis, the underlying factor structure of the ASCOT and the ICECAP-O was examined for the first time. Convergent and discriminant validity in relation to health measures (five-level EuroQol five-dimensional questionnaire, EuroQol Visual Analogue Scale, Barthel Index, and Geriatric Depression Scale-15) and well-being measures (Older People’s Quality of Life Questionnaire-13, Satisfaction with Life Scale, and Cantril’s Ladder) were tested using Spearman rank correlations and variance analysis.

Results

The ASCOT and the ICECAP-O tapped into a shared factor, whereas both measures also loaded on two separate factors. The ASCOT and the ICECAP-O correlated highly with the health and well-being measures, but the correlation with the physical health measure Barthel Index was moderate. Both measures discriminated between subgroups of respondents.

Conclusions

The ASCOT and the ICECAP-O seem promising measures to evaluate well-being among older people, whereby the ASCOT seems more specific to social care–related outcomes. The performance of both measures in other respondent groups and countries, and their relation to physical health, need to be further examined before their use in economic evaluations can be recommended.  相似文献   

12.
Objectives: To explore whether Alzheimer’s disease patients could rate their quality of life (QOL) using utility-based health indexes, and to provide new knowledge about the measurement properties of these instruments for patient and caregiver proxy ratings. Methods: A convenience sample of 60 mild-moderate AD patients and their caregivers were randomized to complete the Quality of Well-Being Scale (QWB), Health Utilities Index (HUI3) or EQ-5D and visual analogue scale (VAS) on two occasions. Test–retest reliability (intraclass correlation coefficients) and convergent validity (Spearman correlations) of utility scores with global health status, activities of daily living, comorbidity, mood, cognition and other utility measures were assessed. Results: Completion time was shortest for the combined EQ-5D and VAS. For patients with mild dementia and for proxies, reliability was ≥ 0.70 for the EQ-5D, QWB and HUI3. The EQ-5D had a ceiling effect for patient ratings. Convergent validity was demonstrated for patient and proxy ratings, with the strongest validity for EQ-5D ratings and the weakest validity for HUI3 patient ratings. Mean patient utility scores were significantly higher than mean proxy scores for all measures (p<0.001). Conclusions: For patient and proxy ratings, the EQ-5D had the best combination of measurement properties, although it had a substantial ceiling effect for patient ratings. Proxy QOL ratings did not accurately reflect patients’ ratings.  相似文献   

13.

Purpose

This study aimed to ascertain the psychometric properties of EuroQol Five Dimensional Questionnaire (EQ-5D-3L) in primary caregivers of children with autism. The convergent validity, discriminant validity, known-groups validity, internal consistency reliability, and floor and ceiling effects of EQ-5D-3L were analyzed.

Methods

A cross-sectional design was used for study purposes. Through an online survey, relevant study information was collected from 316 primary caregivers of children with autism. Study participants were from families of children with autism living in the United States who were registered with the Interactive Autism Network. Convergent validity of the EQ-5D-3L was assessed through its correlation with other measures of similar constructs. Discriminant validity was assessed by observing the correlation of EQ-5D-3L domains with theoretically unrelated constructs. Known-groups validity was tested by comparing EQ-5D-3L index and visual analog scale (VAS) scores across levels of autism severity among the care recipients. Internal consistency reliability of EQ-5D-3L was tested. Lastly, floor and ceiling effects of EQ-5D-3L were assessed.

Results

More than 60 % of participants reported problems of ‘anxiety/depression.’ Convergent and discriminant validity of the EQ-5D-3L was good. Significant correlation (convergent validity) was observed among EQ-5D-3L index and VAS and (SF-12v2) physical component summary and mental component summary scores. Caregivers’ EQ-5D-3L index and VAS scores varied by levels of autism severity among care recipients, providing evidence of known-groups validity. Reliability assessed through Cronbach’s alpha was less than satisfactory; however, corrected item-total correlations were adequate.

Conclusions

The EQ-5D-3L is a psychometrically sound tool to elicit health state preferences among caregivers of children with autism.  相似文献   

14.
《Value in health》2021,24(12):1720-1727
ObjectivesStudies face challenges with missing 5-level EQ-5D (EQ-5D-5L) data, often because of the need for longitudinal EQ-5D-5L data collection. There is a dearth of validated methodologies for dealing with missing EQ-5D-5L data in the literature. This study, for the first time, examined the possibility of using retrospectively collected EQ-5D-5L data as proxies for the missing data.MethodsParticipants who had prospectively completed a 3rd month postdischarge EQ-5D-5L instrument (in-the-moment collection) were randomly interviewed to respond to a 2nd “retrospective collection” of their 3rd month EQ-5D-5L at 6th, 9th, or 12th month after hospital discharge. A longitudinal single imputation was also used to assess the relative performance of retrospective collection compared with the longitudinal single imputation. Concordances between the in-the-moment, retrospective, and imputed measures were assessed using intraclass correlation coefficients and weighted kappa statistics.ResultsConsiderable agreement was observed on the basis of weighted kappa (range 0.72-0.95) between the mobility, self-care, and usual activities dimensions of EQ-5D-5L collected in-the-moment and retrospectively. Concordance based on intraclass correlation coefficients was good to excellent (range 0.79-0.81) for utility indices computed, and excellent (range 0.93-0.96) for quality-adjusted life-years computed using in-the-moment compared with retrospective EQ-5D-5L. The longitudinal single imputation did not perform as well as the retrospective collection method.ConclusionsThis study demonstrates that retrospective collection of EQ-5D-5L has high concordance with “in-the-moment” EQ-5D-5L and could be a valid and attractive alternative for data imputation when longitudinally collected EQ-5D-5L data are missing. Future studies examining this method for other disease areas and populations are required to provide more generalizable evidence.  相似文献   

15.
ObjectiveGeneric, preference-based health-related quality of life (HRQoL) instruments is increasingly used in health-care decision-making process. However, to our knowledge, no such HRQoL instrument has been validated or used in chronic prostatitis. We therefore aimed to assess and compare the psychometric properties of EuroQol (EQ-5D) and Short Form 6D (SF-6D) among chronic prostatitis patients in China.MethodsConsenting patients were interviewed using EQ-5D and SF-6D. Convergent and discriminative construct validities were examined with five and two a priori hypotheses, respectively. Sensitivity was compared using receiver operating characteristic (ROC) curves and relative efficiency (RE) statistics. Agreement between instruments was assessed with intra-class correlation coefficients and Bland–Altman plot, while factors affecting utility difference were explored with multiple liner regression models.ResultsIn 268 subjects, mean (SD) EQ-5D and SF-6D utility scores were comparable at 0.73 (0.15) and 0.75 (0.10), respectively. Five of the seven hypotheses for construct validity were fulfilled in both instruments. The areas under ROC of them all exceeded 0.5 (P < 0.001). SF-6D had 9.7–19.9% higher efficiency than EQ-5D at detecting the difference in chronic prostatitis symptom severity. Despite no significant difference in utility scores between two instruments, lack of agreement was observed with low intraclass correlation coefficient (0.218–0.630) and Bland–Altman plot analysis. Chronic prostatitis symptom severity significantly (P < 0.05) influenced differences in utility scores between EQ-5D and SF-6D.ConclusionsBoth EQ-5D and SF-6D are demonstrated to be valid and sensitive HRQoL measures in Chinese chronic prostatitis patients, with SF-6D showing better HRQoL dimension coverage, greater sensitivity, lower ceiling effect, and more rational distribution. Further research is needed to determine longitudinal response and reliability.  相似文献   

16.
Zhu  Juan  Yan  Xin-Xin  Liu  Cheng-Cheng  Wang  Hong  Wang  Le  Cao  Su-Mei  Liao  Xian-Zhen  Xi  Yun-Feng  Ji  Yong  Lei  Lin  Xiao  Hai-Fan  Guan  Hai-Jing  Wei  Wen-Qiang  Dai  Min  Chen  Wanqing  Shi  Ju-Fang 《Quality of life research》2021,30(3):841-854
Purpose

To compare the performance of three-level EuroQol five-dimensions (EQ-5D-3L) and five-level EuroQol five-dimensions (EQ-5D-5L) among common cancer patients in urban China.

Methods

A hospital-based cross-sectional survey was conducted in three provinces from 2016 to 2018 in urban China. Patients with breast cancer, colorectal cancer, or lung cancer were recruited to complete the EQ-5D-3L and EQ-5D-5L questionnaires. Response distribution, discriminatory power (indicator: Shannon index [H′] and Shannon evenness index [J′]), ceiling effect (the proportion of full health state), convergent validity, and health-related quality of life (HRQoL) were compared between the two instruments.

Results

A total of 1802 cancer patients (breast cancer: 601, colorectal cancer: 601, lung cancer: 600) were included, with the mean age of 55.6 years. The average inconsistency rate was 4.4%. Compared with EQ-5D-3L (average: H′?=?1.100, J′?=?0.696), an improved discriminatory power was observed in EQ-5D-5L (H′?=?1.473, J′?=?0.932), especially contributing to anxiety/depression dimensions. The ceiling effect was diminished in EQ-5D-5L (26.5%) in comparison with EQ-5D-3L (34.5%) (p?<?0.001), mainly reflected in the pain/discomfort and anxiety/depression dimensions. The overall utility score was 0.790 (95% CI 0.778–0.801) for EQ-5D-3L and 0.803 (0.790–0.816) for EQ-5D-5L (p?<?0.001). A similar pattern was also observed in the detailed cancer-specific analysis.

Conclusions

With greater discriminatory power, convergent validity and lower ceiling, EQ-5D-5L may be preferable to EQ-5D-3L for the assessment of HRQoL among cancer patients. However, higher utility scores derived form EQ-5D-5L may also lead to lower QALY gains than those of 3L potentially in cost-utility studies and underestimation in the burden of disease.

  相似文献   

17.
Background

The EQ-5D and the SF-6D are examples of commonly used generic preference-based instruments for assessing health-related quality of life (HRQoL). However, their suitability for mental disorders has been repeatedly questioned.

Objective

To assess the responsiveness and convergent validity of the EQ-5D-3L and SF-6D in patients with depressive symptoms.

Methods

The data analyzed were from cardiac patients with depressive symptoms and were collected as part of the SPIRR-CAD (Stepwise Psychotherapy Intervention for Reducing Risk in Coronary Artery Disease) trial. The EQ-5D-3L and SF-6D were compared with the HADS (Hospital Anxiety and Depression Scale) and PHQ-9 (Patient Health Questionnaire) as disease-specific instruments. Convergent validity was assessed using Spearman’s rank correlation. Effect sizes were calculated and ROC analysis was performed to determine responsiveness.

Results

Data from 566 patients were analysed. The SF-6D correlated considerably better with the disease-specific instruments (|rs|= 0.63–0.68) than the EQ-5D-3L (|rs|= 0.51–0.56). The internal responsiveness of the SF-6D was in the upper range of a small effect (ES: − 0.44 and − 0.47), while no effect could be determined for the EQ-5D-3L. Neither the SF-6D nor the EQ-5D-3L showed acceptable external responsiveness for classifying patients’ depressive symptoms as improved or not improved. The ability to detect patients whose condition has deteriorated was only acceptable for the EQ-5D-3L.

Conclusion

Overall, both the convergent validity and responsiveness of the SF-6D are better than those of the EQ-5D-3L in patients with depressive symptoms. The SF-6D appears, therefore, more recommendable for use in studies to evaluate interventions for this population.

  相似文献   

18.
《Value in health》2023,26(7):1045-1056
ObjectivesWe aimed to compare measurement properties of the 5-level version of EQ-5D (EQ-5D-5L) and 2 Patient-Reported Outcomes Measurement Information System (PROMIS) short forms, PROMIS-29+2 and PROMIS Global Health (PROMIS-GH-10), and of EQ-5D-5L and PROMIS-preference scoring system (PROPr) utilities.MethodsA cross-sectional survey was conducted in a general population sample in Hungary (N = 1631). We compared the following measurement properties at the level of items, domains, and utilities, the latter using corresponding US value sets: ceiling and floor, informativity (Shannon’s indices), agreement, convergent, and known-group validity. For the analyses, PROMIS items/domains were matched to EQ-5D-5L domains that cover similar concepts of health.ResultsThe majority of PROMIS items showed enhanced distributional characteristics, including lower ceilings and higher informativity than the EQ-5D-5L. Good convergent validity was established between EQ-5D-5L and PROMIS domains capturing similar aspects of health. Mean EQ-5D-5L utilities were substantially higher than those of PROPr (0.864 vs 0.535). EQ-5D-5L utilities correlated moderately or strongly with PROPr (r = 0.61), PROMIS-GH-10 physical (r = 0.68), and mental health summary scores (r = 0.53). EQ-5D-5L utilities decreased with age, whereas PROPr utilities slightly increased with age. EQ-5D-5L utilities discriminated significantly better in 12/28 (ratio of F-statistics) and 18/26 (area under the receiver-operating characteristics curve ratio) known groups defined by age, self-perceived health status, and self-reported physician-diagnosed health conditions, including hypertension, diabetes, coronary heart disease, chronic kidney disease, and stroke.ConclusionsThis study provides comparative evidence on the measurement properties of EQ-5D-5L, PROMIS-29+2, and PROMIS-GH-10 and informs decisions about the choice of instruments in population health surveys for assessment of patients’ health and for cost-utility analyses.  相似文献   

19.
《Value in health》2022,25(5):824-834
ObjectivesThe Patient-Reported Outcome Measurement Information System (PROMIS) Preference score (PROPr) can be used to assess health state utility (HSU) and estimate quality-adjusted life-years in cost-effectiveness analyses. It is based on item response theory and promises to overcome limitations of existing HSU scores such as ceiling effects. The PROPr contains 7 PROMIS domains: cognitive abilities, depression, fatigue, pain, physical function, sleep disturbance, and ability to participate in social roles and activities. We aimed to compare the PROPr with the 5-level EQ-5D (EQ-5D-5L) in terms of psychometric properties using data from 3 countries.MethodsWe collected PROMIS-29 profile and EQ-5D-5L data from 3 general population samples (United Kingdom = 1509, France = 1501, Germany = 1502). Given that cognition is not assessed by the PROMIS-29, it was predicted by the recommended linear regression model. We compared the convergent validity, known-groups construct validity, and ceiling and floor effects of the PROPr and EQ-5D-5L.ResultsThe mean PROPr (0.48, 0.53, 0.48; P<.01) and EQ-5D-5L scores (0.82, 0.85, 0.83; P<.01) showed significant differences of similar magnitudes (d = 0.34; d = 0.32; d = 0.35; P<.01) across all samples. The differences were invariant to sex, income, occupation, education, and most conditions but not for age. The Pearson correlation coefficients between both scores were r = 0.74, r = 0.69, and r = 0.72. PROPr’s ceiling and floor effects both were minor to moderate. The EQ-5D-5L’s ceiling (floor) effects were major (negligible).ConclusionsBoth the EQ-5D-5L and the PROPr assessed by the PROMIS-29 show high validity. The PROPr yields considerably lower HSU values than the EQ-5D-5L. Consequences for quality-adjusted life-year measurements should be investigated in future research.  相似文献   

20.
《Value in health》2020,23(6):782-790
ObjectivesCarer quality-of-life (QoL) effects are recommended for inclusion in economic evaluations, but little is known about the relative performance of different types of QoL measures with carers. This study evaluated the validity and responsiveness of 3 care-related QoL measures (the Carer Experience Scale [CES], CarerQoL-7D, and ASCOT-Carer), 1 health-related QoL measure (the EQ-5D-5L), and 1 generic QoL measure (the ICECAP-A).MethodsValidity and responsiveness were assessed in a UK sample of informal carers of adults with dementia, stroke, mental illness, or rheumatoid arthritis. A questionnaire containing the 5 QoL measures was posted to carers identified through the Family Resources Survey (N = 1004). Hypotheses regarding the anticipated associations between constructs related to the QoL of carers were tested to investigate construct validity and responsiveness.ResultsEach measure exhibited some level of construct validity. In general, larger effect sizes and stronger associations were detected for the ASCOT-Carer and ICECAP-A measures in the pooled sample and across all conditions. The 5 measures did not exhibit clear responsiveness to changes over a 12-month period in care recipient health status or hours of care provided per week.ConclusionThe results of this study provide initial evidence of the validity of care-related, health-related, and generic QoL (capability) measures in informal carers of adults with 4 highly prevalent conditions. Care-related measures were not always more sensitive to constructs associated with QoL of carers compared with generic measures. The performance of the ICECAP-A was comparable with that of the best-performing care-related measure, the ASCOT-Carer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号