首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
目的 探讨CT引导徒手腔内联合插植实现影像引导自适应后装(IGABT)相较于传统A点二维后装(CP)剂量学优势,明确其在宫颈癌治疗中的价值。方法 选取在中山大学肿瘤医院行全量放疗的宫颈癌患者 26例,每例患者行4次后装治疗。治疗时先徒手置入宫腔管及2根插植针,后增加插植针数量并调整方向、深度,分别行CT扫描获得2套图像。勾画高危临床靶区(HRCTV),A点和危及器官(直肠、膀胱及乙状结肠)。在2套图像上分别行CP和IGABT计划设计,并配对t检验、Wilcoxon检验两者剂量参数差异。结果 以CP计划的覆盖指数(CI)进行分组,A组(CI≥0.90)包含20个CP和对应IGABT计划,B组(CI<0.90)包含84个CP和对应IGABT计划。A组的HRCTV体积及肿瘤直径明显小于B组(46.7cm3∶62.1cm3,P<0.001及3.1cm∶4.4cm,P<0.0001)。IGABT显著提高所有及B组D90%及覆盖指数,降低膀胱剂量,减少A组乙状结肠剂量,并改善剂量适形度及均匀性。结论 IGABT能提高靶区覆盖、剂量适形度和均匀性,保护危及器官,且对肿瘤较大的患者仍有优势。  相似文献   

2.
目的 通过对CT引导的宫颈癌三维与二维近距离放疗计划的剂量学比较,探讨不同位置子宫对危及器官剂量分布和靶区适形度的影响以及二维近距离放疗治疗宫颈癌的最适人群。方法 纳入我科30例宫颈癌患者的72 次三维近距离放疗计划,并重新设计二维计划,测量子宫位置前后、左右偏离角度。分别按照宫体前后偏离角度(T)及HRCTV体积(VHRCTV)将数据分为A、B、C、D及Ⅰ、Ⅱ、Ⅲ、Ⅳ组,以探寻二维计划最适子宫位置和HRCTV体积范围。统计采用配对t检验差异。结果 宫体前后偏离角度与两种计划的CI值及HRCTV D90无相关性(P值为0.077~0.633),与两种计划中膀胱D2 cm3呈正相关(P值为0.001~0.030),直肠D2 cm3呈负相关(P值为0.011~0.016)。B组(|T|≤10°)及Ⅲ组(VHRCTV为86~96 cm3)中两种计划危及器官参数及CI 值均相近(P值为0.040~0.463);而其他组均有不同程度上的差异(P值为0.000~0.940)。结论 子宫前后位置虽然不影响靶区适形度,但会干扰周围危及器官剂量分布,而当子宫位置接近平位(前后偏离角度≤10°)、靶区体积适当(VHRCTV为86~96 cm3)时两种计划的剂量学相近,此时最适采用二维近距离放疗。  相似文献   

3.
目的:基于宫颈癌近距离治疗中隐匿性穿孔CT图像,评价三维计划和二维计划剂量学差异,为临床提供参考。方法:回顾2019—2020年间在重庆大学附属肿瘤医院行单纯腔内(宫腔管+穹隆管)三维近距离治疗宫颈癌817人次,其中发生隐匿性子宫穿孔16人次。基于Oncentra Brachy Therapy计划系统,单次处方剂量6G...  相似文献   

4.
目的 探讨3D打印模板辅助标准化施源器在宫颈癌影像引导自适应近距离治疗(BT)中的应用。方法 对 23例外照射(45Gy分25次)后宫旁受侵袭范围较大的 ⅢB期宫颈癌患者行MRI引导自适应BT,处方剂量为7 Gy/次,共4次。根据外照射前后MRI中肿瘤消退情况确定BT范围,预估应用标准化腔内联合组织间插植(IC+IS)施源器剂量欠量区域。对欠量区域虚拟经会阴组织间插植针道,并优化植入角度、间距、深度等。应用图形设计软件设计辅助插植模板,并使用3D打印技术打印辅助模板,并与标准化施源器结合紧密。在全麻条件下超声引导完成IC+IS,术后对患者行MRI定位扫描。将定位MRI传入治疗计划系统进行靶区和危及器官勾画,并给予IC+IS治疗计划设计优化,最终完成计划评估及治疗。结果 3D打印个体化插植模板平均打印时间为(3.5±1.0) h,辅助模板共引导植入插植针382根,单分次(4.2±1.5)根,剂量权重比为(16.49±9.50)%。靶区EQD2Gy,α/β=10剂量高危靶 区D90%为(90.45±3.03) Gy,中危靶 区D90%为(66.46±3.68) Gy。膀胱、直肠、小肠、乙状结肠的 D2cm3EQD2Gy,α/β=3分别为(82.69±2.60)、(73.20±2.52)、(69.35±3.32)、(69.39±3.27) Gy,均满足临床剂量要求。1年和 2年局部控制率、无远处转移生存率、总生存率分别为96%和87%、87%和70%、96%和78%。结论 利用3D打印技术制作的辅助插植施源器可以有效弥补现有标准化施源器在 ⅢB期宫颈癌临床BT时大体积靶区剂量的不足,为晚期宫颈癌BT提供了较为有效的方法。  相似文献   

5.
目的 比较宫颈癌腔内结合插植后装治疗(IC/IS BT)时徒手方式插针计划与虚拟优化插针计划的剂量学差异,探讨现有插植后装计划的改善空间。方法 回顾性分析18例宫颈癌高剂量率放疗计划,利用Nucletron Oncentra三维近距离治疗计划系统在已实施的徒手方式插植后装治疗计划(Treatment-Plan)的基础上,再为每例患者设计一个虚拟优化插植后装治疗计划(Optimized-Plan)。运用剂量体积直方图评估两种计划的高危临床靶区剂量分布、危及器官受量及计划执行效率。结果 两种计划相比较,Optimized-Plan显示出更适形的靶区覆盖和更均匀的剂量分布(P=0.000、0.008)。膀胱、直肠、乙状结肠和小肠的D0.01 cm3、D1 cm3、D2 cm3和D5 cm3差异均有统计学意义(P<0.05),Optimized-Plan可以降低危及器官受量,膀胱、直肠、乙状结肠、小肠D2 cm3分别减小60.41、36.43、27.53、12.43 cGy。计划执行时间上,Treatment-Plan为(857.92±243.39) s,Optimized-Plan为(804.53±239.13) s,平均缩短53.39s (P<0.001)。结论 虚拟优化插针计划比徒手方式插针计划显示出更适形的靶区覆盖和更均匀的剂量分布,同时各危及器官受量都有不同程度降低,计划执行时间缩短。  相似文献   

6.
目的 比较宫颈癌腔内结合插植后装治疗(IC/IS BT)时徒手方式插针计划与虚拟优化插针计划的剂量学差异,探讨现有插植后装计划的改善空间。方法 回顾性分析18例宫颈癌高剂量率放疗计划,利用Nucletron Oncentra三维近距离治疗计划系统在已实施的徒手方式插植后装治疗计划(Treatment-Plan)的基础上,再为每例患者设计一个虚拟优化插植后装治疗计划(Optimized-Plan)。运用剂量体积直方图评估两种计划的高危临床靶区剂量分布、危及器官受量及计划执行效率。结果 两种计划相比较,Optimized-Plan显示出更适形的靶区覆盖和更均匀的剂量分布(P=0.000、0.008)。膀胱、直肠、乙状结肠和小肠的D0.01 cm3、D1 cm3、D2 cm3和D5 cm3差异均有统计学意义(P<0.05),Optimized-Plan可以降低危及器官受量,膀胱、直肠、乙状结肠、小肠D2 cm3分别减小60.41、36.43、27.53、12.43 cGy。计划执行时间上,Treatment-Plan为(857.92±243.39) s,Optimized-Plan为(804.53±239.13) s,平均缩短53.39s (P<0.001)。结论 虚拟优化插针计划比徒手方式插针计划显示出更适形的靶区覆盖和更均匀的剂量分布,同时各危及器官受量都有不同程度降低,计划执行时间缩短。  相似文献   

7.
目的 探讨三维后装治疗计划中一种逆向剂量优化算法(GBPO)的实现方法和结果。方法 GBPO使用标准的二次目标函数,优化代码基于LBFGS算法。回顾性选择了 7例使用不同施源器治疗的宫颈癌患者和 15例使用了三管施源器治疗的宫颈癌患者,先用等剂量线定性评估GBPO计划的质量,然后统计剂量体积直方图(DVH)参数(CTV D100%、V150%,危及器 官D0.1cm3、D1.0cm3、D2.0cm3),评估GBPO计划、IPSA计划和Graphic计划之间的差异。结果 对于使用不同施源器的 7例患者,GBPO都可以优化出适形的剂量分布,GBPO计划、IPSA计划和Graphic计划之间靶区和危及器官的DVH参数相近。对于使用了三管施源器的 15例患者,GBPO计划和IPSA计划之间DVH参数也相近,GBPO计划和Graphic计划之间危及器官DVH参数也相近,但是GBPO计划CTV的D100%高于Graphic计划(P<0.01),V150%低于Graphic计划(P<0.01)。结论 采用逆向剂量优化算法GBPO制订的计划在靶区覆盖和危及器官保护方面与IPSA计划相似,GBPO可集成在三维后装治疗计划系统中。  相似文献   

8.
目的 探讨60Co高剂量率三维后装在儿童阴道横纹肌肉瘤放疗中的应用流程,并从剂量学角度分析可行性。方法 选取5例已行儿童阴道横纹肌肉瘤放疗患儿CT定位图像,分别设计3种治疗计划:计划A为3DCRT外照射,计划B为后装治疗,计划C为后装治疗联合外照射。根据EQD2评估CTV和OAR剂量学参数并单因素方差分析。结果 与计划A相比,计划C的CTV的D90、D50、Dmean更高(P=0.00),直肠、膀胱和股骨头剂量低,卵巢剂量略高(P=0.00)。与计划B相比,计划C的CTV 的D90更高,D50、Dmean较低,卵巢剂量较低,直肠、膀胱和股骨头剂量略高。计划B的直肠、膀胱D2 cm3最低。结论 儿童阴道横纹肌肉瘤的放疗需根据原发肿瘤位置及手术后是否残留选择合适的治疗方式。CT引导的60Co高剂量率三维后装治疗方式流程简单快捷,患儿耐受性好,靶区剂量高,正常组织保护好。  相似文献   

9.
目的 探讨宫颈癌患者多次计划CT引导的三维近距离治疗可行性及对危及器官剂量学影响。
方法 10例接受根治性放疗的Ⅱb~Ⅲb期宫颈癌患者每次腔内放疗前行CT扫描并勾画高危临床靶体积(HRCTV)及膀胱、直肠、乙状结肠。PLATO14.3计划系统设计,HRCTV采用D90,危及器官采用D2 cm3评价。处方剂量A点7 Gy单次后进行几何优化,直肠、乙状结肠D2 cm3≤5 Gy,膀胱D2 cm3≤5.5 Gy。第1次腔内治疗优化计划为标准计划,每次腔内放疗进行CT扫描制定几何优化计划。两组计划参数行独立样本t检验,危及器官体积与参数相关性采用Pearson法相关分析。
结果
标准计划与优化计划HRCTV的D90相似(t=-0.03~-1.61,P=0.978~0.128),膀胱、直肠、乙状结肠D2 cm3不同(t=-2.27~-3.35,P=0.049~0.004)。膀胱、直肠、乙状结肠体积与各自D2 cm3均呈正相关(r=0.314、0.407、0.539,P=0.026、0.003、0.000)。
结论 CT引导的宫颈癌三维近距离治疗中多次计划有必要,危及器官体积对治疗CTV剂量无影响,但体积越大受照最多部位的D2 cm3越高。  相似文献   

10.
目的 探索等效均匀剂量(EUD)在宫颈癌腔内联合插植近距离治疗(BT)计划中的应用。方法 随机选取在天津医科大学肿瘤医院接受腔内联合插植BT的宫颈癌患者20例,分别进行基于EUD和混合EUD (h-EUD)计划的优化设计,分析比较计划结果与预先的混合逆计划优化(HIPO)计划间剂量学差异。为进一步评估EUD目标在优化设计中的作用,对所有病例增加了虚拟的均匀组织间插植实验。结果 3种优化计划具有相似的适形指数,与HIPO计划相比,EUD计划的膀胱、直肠、小肠平均D2cm3分别减少了0.22、0.23、0.28 Gy,平均EUD分别减少了0.14、0.20、0.15 Gy;h-EUD计划的膀胱、直肠、小肠平均D2cm3分别减少了0.16、0.22、0.24 Gy,平均EUD分别减少了0.20、0.13、0.16Gy (P均<0.05)。在虚拟插植实验中,EUD目标能对危及器官提供更加显著的剂量改善。结论 宫颈癌腔内联合插植BT采用EUD优化方法能在保证靶区剂量基本一致,并有效降低正常组织受量、改善治疗计划。  相似文献   

11.
目的 介绍一种经阴道3D打印后装腔内联合插植治疗个体化模板设计方法,比较该方法和徒手插植方法的剂量学和操作安全性差异。方法 研究选取40例行192Ir高剂量率腔内联合插植后装治疗计划。实验组为20例使用经阴道3D后装个体化模板设计方法,用基于CT影像的预计划方法设计插植针路径,用3D打印技术创建个体化模板实体和插植针路径,最后在CT引导下置入模板。对照组选取20例腔内联合徒手插植治疗计划,徒手插植方法不做预计划并且插植针方向由操作医生经验决定。结果 两组计划HR-CTV的分次D90相近,实验组正常组织D2cm3的剂量有较显著改善,且肿瘤靶区内高剂量区体积和剂量适形性指数均有改善。实验组共使用273次插植针,脱靶次数为1次,未出现插植针刺穿正常组织事件。对照组共使用203次插植针,脱靶次数4次,且观察到3次刺穿正常组织事件。结论 3D打印后装腔内联合插植治疗个体化模板方法对比徒手插植方法有剂量学优势,并且操作更安全,实际治疗可达到预计划剂量设计要求。  相似文献   

12.
目的 探讨中晚期宫颈癌三维后装腔内放疗中三通道施源器的通道设计与OAR、靶区剂量间关系。方法 调取2015—2016年我院三维腔内治疗的15例中晚期宫颈癌数据,其中30次“阴道卵形两半球+宫腔管”的三通道施源器剂量参数纳入研究。在原靶区和OAR勾画、处方剂量不变基础上保留宫腔管单通道施源器,重新进行三维腔内照射设计的剂量参数作为对照组,配对t检验两组OAR剂量参数。结果 三通道、单通道施源器组直肠D2cc分别为(387.8±96.8)、(340.8±88.1) cGy;两组膀胱和乙状结肠D2cc分别为(443.2±87.5)、(719.4±243.0) cGy和(330.3±88.8)、(383.1±105.6) cGy。三通道组满足直肠(D2cc≤500 cGy)、膀胱(D2cc≤550 cGy)和乙状结肠(D2cc≤500 cGy)计划限量,单通道组膀胱和乙状结肠D2cc受量分别为大于和部分大于计划限量。单通道组膀胱和乙状结肠D2cc受量高于三通道组(P均<0.05)。结论 宫颈癌三维腔内放疗中“阴道卵形两半球+宫腔管”三通道施源器比宫腔管单通道可有效降低膀胱和乙状结肠受量,有利于计划优化和剂量实施。  相似文献   

13.
目的 研究后装腔内/组织间插植近距离治疗(IC/ISBT)与传统后装腔内近距离治疗(ICBT)相比较的剂量学差异及其近期疗效。方法 45例局部晚期宫颈癌患者采用IC/ISBT及ICBT方法进行后装近距离治疗,分别对两种治疗方法的A点(A1、A2)、D90%、D100%以及膀胱、结肠、直肠、小肠受量进行计算,同时观察近期疗效。结果 IC/ISBT比ICBT放疗A点剂量显著提升(P<0.05);并且IC/ISBT的D90%、D100%也均明显高于ICBT (P<0.05)。外照射后残存肿瘤直径≥3cm时,IC/ISBT比ICBT可获得较高的靶区剂量提升(P<0.05)。IC/ISBT与ICBT的膀胱、直肠、结肠、小肠D2cm3、D0.1cm3相近(P>0.05)。疗后1、3、6个月的近期疗效IC/ISBT与ICBT相近(P>0.05)。结论 局部晚期宫颈癌(残存肿瘤直径≥3cm)后装近距离治疗中IC/ISBT在不增加危及器官受量及降低近期疗效前提下显著地提高了靶区、A点剂量,具有明显剂量学优势。  相似文献   

14.
Objective To study the dosimetric differences and short-term efficacy between intracavitary/interstitial brachytherapy (IC/ISBT) and conventional intracavitary brachytherapy (ICBT). Methods Forty-five patients with locally advanced cervical cancer were treated with IC/ISBT and ICBT. Points A (A1,A2), D90%, D100%, organs at risk, and the doses of bladder, colon, rectum and small intestine were calculated and the short-term efficacy was observed between two groups. Results Point A dose was significantly improved in IC/ISBT compared with ICBT (P<0.05). The D90% and D100% in IC/ISBT were significantly higher than those in ICBT (both P<0.05). After brachytherapy, IC/ISBT could obtain a significantly larger increase in target dose when residual tumor diameter was ≥3 cm compared with ICBT (P<0.05). The D2cm3 and D0.1cm3 of bladder, rectum, colon and small intestine did not significantly differ between IC/ISBT and ICBT (all P>0.05). The 1-,3-and 6-month clinical efficacy did not significantly differ between two technologies (all P>0.05). Conclusion During brachytherapy for locally advanced cervical cancer (residual tumor diameter ≥3 cm), IC/ISBT significantly increases the doses of target area and point A without increasing the dose of organs at risk or lowering the short-term clinical efficacy, which has significant dosimetric advantages.  相似文献   

15.
目的 通过比较子宫内膜癌腔内近距离治疗3D计划和2D计划,探讨子宫内膜癌3D腔内近距离治疗的剂量学特性。方法 回顾性分析11例子宫内膜癌患者的39次3D近距离治疗计划并重新设计2D计划,从DVH上比较靶区V150、D90,膀胱、直肠、小肠及乙状结肠D2 cm3 。采用配对t检验方法分析组间差异。结果 靶体积<60 cm3时,3D、2D计划靶区D90分别为(551.17±90.33)、(574.15±117.18) cGy (P=0.390),随着靶体积增加3D计划的D90增加(P=0.001)。3D、2D计划靶区V150分别为(51.05±21.61)、(53.41±11.71) cm3(P=0.482)。当靶体积>60 cm3时,与2D计划相比,3D计划提高靶区覆盖同时增加了危及器官受量,但小肠受量增加不明显(P=0.128)。此外,不同计划模式下BMI增加对直肠、小肠、膀胱及乙状结肠的受量无显著影响,P值分别为0.239、0.198、0.744和0.834。结论 子宫内膜癌3D腔内近距离治疗与2D计划相比可显著提高较大靶区的覆盖范围,有效控制OAR受量,临床疗效与不良反应尚需进一步观察。  相似文献   

16.
目的 观察CT图像引导下192Ir三维腔内后装治疗的肿瘤靶区及危及器官受照射体积剂量参数与肿瘤局部控制率及晚期副反应之间关系.方法 10例局部晚期宫颈癌患者在完成盆腔外照射40 Gy及同期化疗后开始每周1次的CT图像引导下192Ir三维腔内后装治疗,每次治疗前进行CT扫描定位,勾画肿瘤靶区(GTV、CTV)和危及器官,利用PLATO治疗计划系统进行逆向治疗计划设计及优化,CTV单次处方剂量为6 Gy,治疗5~7次.结果 1年盆腔控制率为90%,1~2级放射性肠炎发生率为50%,无≥3级副反应.90%CTV等效生物剂量(BED)和相当于2 Gy分次的等效剂量(EQD2)分别为(95.50±7.81)Gy和(79.73±6.57)Gy(α/β=10).90%GTV的BED和EQD2分别为(101.86±7.27)Gy和(84.95±6.1)Gy(α/β=10).90%处方剂量对GTV、CTV的覆盖率分别为92%±4%、87%±7%.直肠、乙状结肠2 cm3体积受到的最小照射剂量分别为(74.97±1.64)、(67.93±4.30)Gy(EQD2,α/β=3).与二维治疗计划相比,三维治疗计划在没有改变A点剂量、直肠参考点剂量情况下提高了GTV、CTV的90%体积受照射剂量及90%处方剂量对GTV、CTV的覆盖率.结论 CT图像引导下192Ir三维腔内后装治疗提高了处方剂量对肿瘤靶区的覆盖率,1年盆腔控制率为90%且无严重副反应,远期疗效观察中.
Abstract:
Objective To investigate the correlation between dose volume histogram(DVH)of tumor targets and organs at risk(OAR)at CT-image based 192Ir brachytherapy and effects and complications for patients with locally advanced cervical cancer. Methods Ten patients with FIGO stage ⅢB cervical cancer received CT image-based 192Ir intracavitary brachytherapy after 54 Gy of three-dimentional four-field pelvic external beam radiotherapy and concurrent weekly cisplatin chemotherapy. Before each brachytherapy,CT images were acquired with applicators in place. Gross tumor volume(GTV), clinical target volume (CTV)and OAR were contoured and inverse treatment planning was designed and optimized by using PLATO treatment planning system. Conventional two-dimensional plans were also designed for comparison.The total intracavitary brachytherapy dose was 30 -42 Gy in 5 -7 fractions. The patients were followed, and the local control and complications were analyzed. The biologically equivalent dose(BED)and biologically equivalent dose in 2 Gy fractions(BED2)for GTV, CTV and OAR were calculated. The minimum dose in the most irradiated tissue volume 2 cm3(D2 cm3)adjacent to the applicator of the sigmoid colon, rectum,bladder and small bowel was determined from the DVH. Results The 1-year local pelvic control rate was 90% and grade 1-2 late complication of sigmoid colon and rectum was 50%. No grade 3 or more complications developed. On CT-image based planning, the BED and BED2 to 90% of the CTV(D90)were 95.50 Gy ± 7. 81 Gy and 79. 73 Gy ± 6. 57 Gy. The BED and BED2 to 90% of the GTV(D90)were 101.86 Gy ± 7.27 Gy and 84. 95 Gy ± 6. 1 Gy. The volume enclosed by 90% of prescribed dose(V90)for GTV and CTV were 92% ±4% and 87% ±7% respectively. The D2cm3 for rectum and sigmoid colon were 74. 97 Gy ±1.64 Gy and 67. 93 Gy ± 4. 30 Gy(EQD2, α/β = 3). Comparing with 2D brachytherapy plans , CT - image based planning has improved D90 and V90 for GTV and CTV with similar dose at point A and rectum reference point. Conclusions Computer tomography-image based 192Ir brachytherapy has resulted in the better dose distribution to the tumor targets with excellent tumor control and acceptable toxicity.  相似文献   

17.
目的 探讨后装放疗计划的鲁棒优化方法在宫颈癌放疗中的应用价值。方法 回顾性选择已完成治疗的根治性宫颈癌患者 20例,用剂量体积直方图(DVH)参数对比常规优化和鲁棒优化计划差异,用DVH和DVH束评估常规优化和鲁棒优化计划的鲁棒性。鲁棒优化方法使用最差剂量分布考虑放疗中不确定因素存在时的剂量,每次优化迭代计算放射源沿人体左右(x轴)、前后(y轴)、头脚(z轴)方向偏移固定值(2mm)时的剂量分布,再加上放射源位置无偏移情况;每个体元的最差剂量分布是这几种情况中靶区内剂量最低值和靶区外剂量最高值,迭代目标函数通过最差剂量分布计算。结果 在没有放射源位置偏移情况下,鲁棒优化HR-CTV D100%均值比常规优化低,而V150%均值比常规优化高(P<0.05)。在考虑放射源位置偏移情况下,对比多种剂量分布的最差剂量学参数,鲁棒优化和常规优化的HR-CTV D100%均值相近,但鲁棒优化 的D90%均值比常规优化高(范围 0.02~0.03Gy)(P<0.05)。鲁棒优化增加了膀胱和小肠的D2cm3,直肠剂量随着鲁棒优化中考虑的放射源位置偏移方向的增加而增加。所有患者的常规优化和鲁棒优化的DVH束宽度相近。结论 基于最差剂量分布的鲁棒优化不能明显地提升宫颈癌后装放疗计划的鲁棒性,需要其他的方式减小后装放疗中的不确定因素对剂量的影响。  相似文献   

18.
目的 探讨CT引导下腔内联合组织间插植3D-IGBT局部晚期宫颈癌的剂量学优势。方法 分析2013—2014年于本院接受根治性外照射及腔内联合组织间插植3D-IGBT的局部晚期宫颈癌患者 45例,FIGO分期(2009年)为 ⅠB2—ⅣA期。同一患者行腔内联合组织间插植 192Ir治疗后,在原影像上去掉插植针作用,仅使用腔内施源器制定治疗计划。比较前后两组计划中高危CTV的 D90%、中危CTV的 D90%和膀胱、直肠、乙状结肠、小肠的 D2 cm3剂量学差异,并行配对t检验。结果 共制定260次后装治疗计划, 其中腔内联合组织间插植治疗计划 130例、腔内治疗计划 130例。腔内联合组织间插植治疗较腔内治疗高危CTV的 D90%、中危CTV的 D90%显著增高(P=0.000、0.000),膀胱、直肠的 D2 cm3显著降低(P=0.000、0.006)。结论 局部晚期宫颈癌使用腔内联合组织间插植3D-IGBT在获得更高靶区剂量的同时降低了膀胱、直肠受量。  相似文献   

19.
肖艳  成慧君  王莉  杨柳  于晓 《癌症进展》2020,(5):496-499
目的探讨后装腔内插植放疗与三维后装腔内放疗治疗局部晚期宫颈癌的疗效与剂量学差异。方法将212例局部晚期宫颈癌患者,按照治疗方法的不同分为A组(106例)和B组(106例)。在体外三维适形调强放疗的基础上,A组采用后装腔内插植放疗,B组采用三维后装腔内放疗。对比两组近期疗效、并发症发生率以及剂量学差异。结果B组患者高危临床靶区D100、D90和中危临床靶区D100、D90均明显低于A组,膀胱、直肠、乙状结肠的D2cm3均明显高于A组,差异均有统计学意义(P﹤0.01)。A组患者总有效率明显高于B组,放射性直肠炎、放射性膀胱炎发生率均明显低于B组,差异均有统计学意义(P﹤0.01)。结论后装腔内插植放疗能够在提升肿瘤组织受照剂量的同时,降低危及器官的受照剂量,提升近期缓解率、控制率,减少不良反应。  相似文献   

20.
目的:分析膀胱体积变化对宫颈癌近距离治疗中肿瘤和正常组织受量的影响。方法:2015年1月至2017年12月于本院首诊的66例拟行根治性放疗的宫颈癌患者,治疗方案采用外照射放疗同期化疗加近距离治疗。均采用同期顺铂40 mg/m2每周方案化疗,外照射均采用常规分割外照射放疗,1.8~2 Gy/次,1次/天,5次/周,盆腔预防放疗剂量45 Gy/25次,阳性区域转移淋巴结处方剂量55~57.5 Gy/25次。后装采用三维自适应近距离放疗,A点剂量6 Gy每次,共4次,采用宫腔管和双侧阴道穹窿管或环形施源器,在定位CT图像上勾画高危临床靶区(high risk clinical tumor volume,HRCTV)、膀胱、直肠、乙状结肠,制定后装治疗计划后行近距离放疗。结果:后装近距离治疗期间,随着膀胱体积增大,膀胱D1cc、D2cc接受的放疗剂量逐渐升高,有显著统计学差异(P<0.001),其中小于49.25 ml膀胱体积组膀胱受辐射量最小。而膀胱体积的变化不影响直肠D1cc和D2cc、乙状结肠D1cc和D2cc、HRCTV D90和HRCTV D95。随着后装次数的增加,膀胱体积有逐渐增加的趋势,虽然第一次后装时膀胱体积与第二、三次后装时膀胱体积无统计学差异,但是第一次后装时膀胱体积与第四次后装时膀胱体积有统计学差异(P=0.02)。结论:近距离治疗过程中控制膀胱体积可以减少膀胱受照射剂量,近距离治疗期间控制膀胱体积小于49.25 ml可能是一个更好地选择。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏