首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.  相似文献   

3.
Abstract   Background and Aim: The incidence of residual opening after repair of postmyocardial infarction ventricular septal defect (VSD) was reported to be 10% to 25%. Redo surgery with remedian sternotomy is more complex than primary surgery and is consequently associated with higher mortality and morbidity due to the myocardial and patent coronary grafts injury during pericardial dissection. Methods: A 59-year-old female patient had coronary artery bypass grafting and closure of post myocardial infarction ventricular septal defect with patch 10 months earlier in a different cardiac center. She was admitted to the hospital for severe congestive heart failure. Results: She was operated because of the residual opening after repair of post myocardial infarction ventricular septal defect. Post myocardial infarction ventricular septal defect closure was performed through the right atrium by on-pump beating heart technique via the right thoracotomy. Conclusions: Closure of post myocardial infarction ventricular septal defect with this technique offers an alternative and safe approach to repair of the residual VSD when the coronary bypass grafts are patent.  相似文献   

4.
In a 12-year period, 127 patients with isolated aortic valve disease underwent valve replacement surgery. Long-term results are presented in regard to patients with operation between 1967 and 1974 and immediate results in the later cases. The main conclusions from the study are that the type of myocardial protection is important for the perioperative mortality rate. This rate was 18% in patients operated on in normothermia and 6% in those with chemical cardioplegia. No significant correlation was found between preoperative NYHA grouping and mortality or complication rate, and the long-term result was independent of the type of valvular prosthesis.  相似文献   

5.
Aortic valve replacement with on-pump beating heart technique   总被引:1,自引:0,他引:1  
BACKGROUND: The aim of this study was to assess the efficacy and applicability of on-pump beating heart aortic valve replacement with retrograde coronary sinus (CS) warm blood perfusion. METHODS: The prospective study included 14 consecutive patients who underwent aortic valve replacement with mechanical prosthesis using retrograde CS perfusion. The operative variables and early outcome of this procedure are presented. RESULTS: Retrograde CS perfusion and venting the heart from the pulmonary vein provided good visualization of the operative field and performance of the operations without any difficulty. Partial oxygen pressures of CS perfusion blood and the returning blood from the coronary ostia were 288.5 +/- 34.4 and 39.6 +/- 4.6 mmHg, respectively. Postoperative peak creatine kinase-MB and troponin T values were mean 77.0 +/- 63.6 IU/L and mean 0.8 +/- 0.7 ng/mL, respectively. No mortality or major complication was observed and all the patients were discharged from the hospital in good condition. CONCLUSIONS: On-pump beating heart aortic valve replacement with retrograde CS warm blood perfusion is a good surgical option, and has the advantage of maintaining physiologic condition of the heart throughout the procedure.  相似文献   

6.
We present a minimally invasive and cosmetic approach to repair atrial septal defect. Fifty-five atrial septal defects were successfully repaired through a minimal right vertical infra-axillary thoracotomy. Every repair was performed on the beating heart with continuous suction through aortic needle vents and with the head of the patient lowered. This approach can be used not only in adults but also in young girls.  相似文献   

7.
A 62-year-old woman with a history of esophageal resection and colon interposition with anterosternal subcutaneous tunnel required replacement of the ascending aorta due to dissecting aortic aneurysm. Preoperative three-dimensional computed tomography enabled us to reveal that right thoracotomy could offer an ascending aortic operation. The patient underwent successful operation under hypothermic circulatory arrest and the right anterolateral thoracotomy provided safe exposure of the diseased ascending aorta even when the suprasternal tunnel precluded conventional median sternotomy.  相似文献   

8.
Controversy exists in management of cardiac trauma as to whether or not injuries of the cardiac valves or septum should be repaired at initial operation. A patient is presented who required immediate mitral valve replacement for acute disruption of the mitral valve apparatus following a transventricular gunshot injury. The need to consider early repair or replacement of injured cardiac valves when they appear to have hemodynamic significance is emphasized.  相似文献   

9.
Mitral valve replacement and coronary artery bypass grafting were performed in an 80-year-old woman through an 8 cm lateral thoracotomy using central cannulation with a balloon aortic cannula. Visualization permitted the delivery of both retrograde and antegrade cardioplegia. This technique provides excellent exposure of the mitral valve and all coronary vessels and decreases the operative risks associated with a sternotomy.  相似文献   

10.
BACKGROUND AND AIM OF THE STUDY: Although neurologic outcome after cardiac surgery is well-established, neurocognitive functions after beating heart mitral valve replacement still needs to be elucidated. The aim of this study was to compare preoperative and postoperative neurocognitive functions in patients who underwent beating heart mitral valve replacement on cardiopulmonary bypass without cross-clamping the aorta. METHODS: The prospective study included 25 consecutive patients who underwent mitral valve replacement. The operations were carried out on a beating heart method using normothermic cardiopulmonary bypass without cross-clamping the aorta. All patients were evaluated preoperatively (E1) and postoperatively (at sixth day [E2] and second month [E3]) for neurocognitive functions. RESULTS: Neurologic deficit was not observed in the postoperative period. Comparison of the neurocognitive test results, between the preoperative and postoperative assessment for both hemispheric cognitive functions, demonstrated that no deterioration occurred. In the three subsets of left hemispheric cognitive function test evaluation, total verbal learning, delayed recall, and recognition, significant improvements were detected at the postoperative second month (E3) compared to the preoperative results (p = 0.005, 0.01, and 0.047, respectively). Immediate recall and retention were significantly improved within the first postoperative week (E2) when compared to the preoperative results (p = 0.05 and 0.05, respectively). CONCLUSIONS: The technique of mitral valve replacement with normothermic cardiopulmonary bypass without cross-clamping of the aorta may be safely used for majority of patients requiring mitral valve replacement without causing deterioration in neurocognitive functions.  相似文献   

11.
12.
OBJECTIVES AND METHOD: We have performed 225 cases of coronary artery bypass grafting (CABG), between October 15 1995 and September 8 1999. We have evaluated the operative results of 121 cases (53.8%) of conventional CABG and 104 cases (46.2%) of minimally invasive coronary artery bypass grafting performed during this period. The average numbers of bypassed grafts was 3.45 for conventional CABG, and 1.41 for minimally invasive coronary artery bypass grafting. Sixty-seven right internal thoracic arteries, 145 left internal thoracic arteries, 71 gastroepiploic arteries, 38 radial arteries and 12 saphenous veins were used for conventional CABG, and 29 right internal thoracic arteries, 81 left internal thoracic arteries, 18 gastroepiploic arteries, 3 radial arteries, 10 saphenous veins and 2 inferior epigastric arteries were used for minimally invasive coronary artery bypass grafting. The total number of 303 grafts were anastomosed to 417 coronary arteries for conventional CABG, and 143 grafts were anastomosed to 147 coronary arteries for minimally invasive coronary artery bypass grafting. RESULTS: Although two saphenous veins were occluded, the early postoperative patency rate was 100% for conventional CABG using right internal thoracic arteries, left internal thoracic arteries, gastroepiploic arteries and radial arteries. Three site of stenosis in 18 left internal thoracic arteries and 2 in 16 right internal thoracic arteries were recognized in minimally invasive coronary artery bypass grafting without the use of stabilizers. One site of stenosis in 63 left internal thoracic arteries was recognized in minimally invasive coronary artery bypass grafting with the use of stabilizers. CONCLUSION: The use of stabilizers enables adaptation of the minimally invasive coronary artery bypass grafting procedure to a wider range of coronary artery bypass procedures, and a higher graft patency can be expected.  相似文献   

13.
Heterotopic heart transplantation was performed via a right thoracotomy in a patient with elevated pulmonary vascular resistance and previous coronary artery bypass grafting using both internal mammary arteries. The right thoracotomy approach is the safest way to approach the native heart while preserving the patent grafts.  相似文献   

14.
15.
The early and the late results of mitral valve replacement were retrospectively evaluated to delineate the concept of selection of the prosthetic valve for the mitral position. The mitral valve was replaced with porcine bioprosthesis (P-B) in 102 patients and with St. Jude Medical prosthesis (SJM) in 341 patients between 1975 and 1987. Operative mortality was 5.3% for the SJM and 8.8% for the P-B group (N.S.). Cumulative duration of follow up was 1479.8 patient-years for the SJM and 888.9 patient-years for the P-B group. Actuarial survival rate was 90% for the SJM at 9 years and 81%, 76% for the P-B group at 10 and 13 years (N.S.). Freedom from valve-related death was 94% for the SJM at 9 years and 94% for the P-B at 13 years (N.S.). Thrombo-embolic complications occurred at an incidence of 0.47%/patient-years (p-y) for the SJM and 0.67%/p-y for the P-B group (N.S.). Freedom from prosthetic valve dysfunction due to primary tissue failure (PTE) lowered rapidly after the seventh postoperative year from 88% to 35% in the P-B group. Prosthetic valve dysfunction free rate was significantly lower in the P-B group compared with the SJM between the seventh post operative year and ninth postoperative year (p less than 0.01). From this analysis, we believe that the SJM prosthesis is suitable cardiac valve prosthesis to the mitral position.  相似文献   

16.
心脏不停跳主动脉瓣或联合瓣膜置换术   总被引:25,自引:0,他引:25  
目的:评价心脏不停跳方法在主动脉瓣或联合瓣膜置换术中的应用价值。方法:经冠状静脉窦逆行持续灌注机器氧合血,使心脏在有节律的空跳情况下完成主动脉瓣和二尖瓣置换,或改为非置管顺行灌注,再行二尖瓣置换或其他合并症的处理,共83例(A组);随机选择20例在间歇灌注冷血含钾心停搏液下完成手术(B组)。检测血液乳酸(LA)、心肌磷酸肌酸激酶同工酶(CPK-MB)、心肌肌钙蛋白T(cTnT)、丙二醛(MDA);观察前乳头肌超微结构改变;Swan-Ganz管测定心排血量(CO)。结果:LA、CPK-MB、cTnT、ET-1、MDA的增高,B组与A组的差异有显著性(P<0.05)。A组心肌超微结构无明显变化;术后无多巴胺等正性肌力药物依赖和严重心律失常;81例恢复顺利,2例分别死于急性肾功能衰竭和感染性休克。B组均需每分钟5-10μg/kg多巴胺才能脱离体外循环机,9例术后使用临时起搏器,1例死于低心输出量综合征。结论:心脏不停跳主动脉瓣或联登的膜置换术,是一种较接近生理状态的心肌保护新方法,有较理想的临床效果。  相似文献   

17.
We report a repeated mitral valve replacement (re-do MVR) using the valve-on-valve technique for a degenerated bioprosthesis. A 49-year-old female, who had had a 29 mm Carpentier-Edwards mitral bioprosthesis for mitral regurgitation 20 years previously, was referred to our institution for dyspnea. She presented with pulmonary edema secondary to severe mitral bioprosthetic valve regurgitation. We replaced the degenerated mitral bioprosthesis with a 25 mm mechanical prosthesis using the valve-on-valve technique, as the struts of the bioprosthesis were embedded in the left ventricular myocardium. Removal of the bioprosthesis may be not only time-consuming but also complicated by cardiac rupture at the atrioventricular junction or the posterior left ventricular wall. The valve-on-valve technique is a simplified procedure that can avoid the potential complications of complete excision of the bioprosthesis. We believe this technique can be a useful strategy for patients with a degenerated mitral bioprosthesis.  相似文献   

18.
19.
AIM: The aim of this study was to evaluate the operative techniques of total arch replacement, the clinical results and the survival curves of patients following this procedure. METHODS: Since December 2001, 92 patients have undergone surgical treatment for aortic dissection and aneurysm. The total aortic arch replacement was performed in 24 of these patients. There were 16 men and 8 women, and the age range was 42 to 81 years with a mean age of 59.4 years. As the operative technique for total arch replacement, we used the 4-branched prosthetic graft, selective cerebral perfusion (SCP), continuous cold blood cardioplegia (CCBC), and open distal anastomosis under circulatory arrest. The combined operations were coronary bypass grafting in 4 patients, aortic valve suspension in 1 patient and a Bentairs procedure in 1 patient. Eleven (73.3%) patients with acute dissection required emergency operation. RESULTS: The hospital mortality rate was 25% (6 of the 24 patients). The causes of death were multiple organ failure (MOF) due to renal and mesenteric ischemia in 3 patients, cerebral infarction in 2 patients, myonephropathic metabolic syndrome (MNMS) in 1 patient, respectively. The data concerning extracorporeal circulation was 204+/-53 min in total pump time, 136+/-43 min in aortic cross clamp time, 83+/-14 min in SCP time and 48+/-10 min in circulatory arrest time, respectively. The long-term result in actuarial survival rate was 76% for 5 years. CONCLUSION: We consider the technique of total arch replacement using 4-branched prosthetic graft, SCP, CCBC, and open distal anastomosis is a useful operative method in patients with aortic aneurysm.  相似文献   

20.
This study examined the long-term results of the CarboMedics prosthetic heart valve. Between July 1990 and May 2000, 256 CarboMedics valve prostheses (120 single aortic, 62 single mitral, and 34 double aortic/mitral) were implanted into 216 patients (mean age 57.8 years). The mean follow-up was 57.7 +/- 36 months (maximum 133 months) with a total of 1,038.4 patient years. Patient survival, including operative deaths, was 85.1% at 10 years. Linearized rates for various complications were thromboembolism 0.39% per patient year, bleeding events 0.39% per patient year; prosthetic valve endocarditis 0.29% per patient year, nonstructural dysfunction 0.87% per patient year, and reoperation 0.39% per patient year. There were no valve thrombosis or structural valve failures in this series. The probabilities of freedom from thromboembolism and reoperation at 10 years were 96.3% and 93.1%, respectively. In conclusion, the CarboMedics valve can be used satisfactorily with a low incidence of thromboembolism and valve thrombosis.  相似文献   