首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
This study was designed to evaluate the midterm (> or = 5 years) clinical and radiographic outcomes of the cementless total hip arthroplasty in 64 Chinese patients (72 hips), which revealed that the mean Harris hip score increased from an average of 44.0 points before operation to 92.4 points at the last follow-up. Excellent results were achieved in 60 hips (83%). No loosening of the components was observed radiographically. No revision of the femoral components was required. Only one focal area of pelvic osteolysis in 1 hip (1%), which requires a revision, and some small focal areas of femoral osteolysis in 12 hips (17%) were observed. The mean linear wear rate was 0.125 mm/y. The survival rate of the acetabular and femoral components for radiographic loosening was 100% (95% confidence interval, 0.93-1.0) and for revision was 98.61% (95% confidence interval, 0.95-1.0). This study indicated that the cementless total hip arthroplasty in patients with osteonecrosis of the femoral head has a satisfactory midterm clinical and radiographic outcomes, but the long-term effect should be further studied.  相似文献   

2.
The purpose of this study was to evaluate midterm clinical and radiographic outcomes associated with hybrid total hip arthroplasty in a consecutive series of 86 Chinese patients (93 hips) with osteonecrosis of the femoral head, which revealed that the mean Harris hip score increased from 39 +/- 6.0 points before operation to 90.4 +/- 4.6 points at the latest follow-up. There was pelvic osteolysis in one hip (1%), which required revision, and some small focal areas of femoral osteolysis in 12 hips (13%) were observed. The mean linear wear rate was 0.143 +/- 0.05 mm/y (0.02-0.45 mm/y). No loosening of the components was observed radiographically. The survival rate of the acetabular and femoral components for revision was 98% (95% confidence interval, 0.96-1.0) and 100% (95% confidence interval, 0.95-1.0). Hybrid total hip arthroplasty in patients with osteonecrosis of the femoral head had a satisfactory clinical and radiographic outcome at a minimum 5 years of follow-up. Because polyethylene wear and osteolysis cannot be avoided, the long-term effect should be further studied.  相似文献   

3.
BackgroundThe purpose of this study is to determine the clinical and radiographic outcomes, mortality rate, complication rate, and revision rate of this ultra-short non-anatomic cementless femoral stem in elderly patients with a femoral neck fracture.MethodsWe reviewed the results of 284 total hip arthroplasties performed with an ultra-short non-anatomic cementless stem in 280 previously active patients with a mean age of 72.8 ± 13 years (range 49-83). The mean follow-up was 9.3 years (range 7-13).ResultsThe mean Harris Hip Score was 86 ± 14 points at final follow-up. The mean Western Ontario and McMaster Universities Osteoarthritis Index score was 24 ± 6 points at the final follow-up. The mean University of California, Los Angeles activity score was 6 points at final follow-up. Osseointegration was seen in all acetabular (100%) and in 276 femoral components (97%). Kaplan-Meier survivorship analysis revealed that the survival rate of the femoral component at 8.3 years was 97% (95% confidence interval 91–100) and that of the acetabular component was 100% (95% confidence interval 94–100) with aseptic loosening or revision as the end point.ConclusionAn ultra-short non-anatomic cementless femoral stem in patients with good bone quality (Dorr A and some Dorr type B bone) is a safe treatment for femoral neck fracture. In patients with poor bone quality (Dorr C type), the results were very poor, and use of this stem should be avoided.  相似文献   

4.
BACKGROUND: Extra-large uncemented components provide several advantages for acetabular revision, but limited information is available on the results of their use. The purpose of this study was to evaluate, at a minimum of five years, the results associated with the use of an extra-large uncemented porous-coated component for acetabular revision in the presence of bone loss. METHODS: Eighty-nine extra-large uncemented hemispherical acetabular components were used for revision after aseptic failure of a total hip arthroplasty in forty-six men and forty-three women (mean age at revision, fifty-nine years; range, thirty to eighty-three years). The revision implant (a Harris-Galante-I or II cup fixed with screws) had an outside diameter of > or = 66 mm in men and > or = 62 mm in women. Seventy-nine patients had a segmental or combined segmental and cavitary acetabular bone deficiency before the revision. Particulate bone graft was used in fifty-four hips and bulk bone graft, in nine. RESULTS: One patient died with the acetabular component intact and two patients were lost to follow-up within five years after the operation. At the time of the last follow--up, four acetabular components had been removed or revised again (two for aseptic loosening). All of the remaining patients were followed clinically for at least five years (mean, 7.2 years; range, 5.0 to 11.3 years). In the hips that were not revised again, only two sockets had definite radiographic evidence of loosening. All four of the sockets that loosened were in hips that had had combined cavitary and segmental bone loss preoperatively. In the hips that were not revised again, the mean modified Harris hip score increased from 56 points preoperatively to 83 points at the time of the most recent follow-up. The most frequent complication, dislocation of the hip, occurred in eleven patients. The probability of survival of the acetabular component at eight years was 93% (95% confidence interval, 85% to 100%) with removal for any reason as the end point, 98% (95% confidence interval, 92% to 100%) with revision for aseptic loosening as the end point, and 95% (95% confidence interval, 88% to 100%) with radiographic evidence of loosening or revision for aseptic loosening as the end point. CONCLUSIONS: This study demonstrates that extra-large uncemented components used for acetabular revision in the presence of bone loss perform very well and have a low rate of aseptic loosening at the time of intermediate-term follow-up.  相似文献   

5.
BACKGROUND: There are few longer-term follow-up reports of the results and complications of the use of cementless acetabular components in revision hip arthroplasty. In this study, we analyzed the clinical and radiographic results to determine the factors that affect longer-term survival of titanium-fiber-metal-coated acetabular components. METHODS: During a fourteen-year period, one surgeon performed 211 consecutive unselected cementless acetabular revisions in 194 patients with a mean age of sixty-two years. The same technique was used for all revisions: the component was impacted and was fixed with multiple screws, and bone deficiencies were augmented with supplemental bone graft. Both the acetabular and the femoral components were revised in 142 hips, whereas an isolated acetabular revision was performed in sixty-nine hips. All 211 revisions were included in a survivorship analysis to twelve years. Prospectively determined clinical results in 135 hips and radiographic results in 131 hips were available at a minimum of five years postoperatively. RESULTS: Seven acetabular components were removed: three, because of infection; one, because of recurrent dislocation; and three, because of mechanical loosening. There was asymptomatic radiographic loosening of one additional acetabular component, for a total rate of aseptic loosening of 2%. The twelve-year prosthetic survival rate was 95% (95% confidence interval, 91% to 99%), with failure defined as component removal for any reason. There was no significant difference in the rate of survival of the cup or femoral component between the sixty-nine hips treated with isolated acetabular revision and the 142 hips in which both components were revised. There was a significant difference in the rate of dislocation between the hips treated with isolated acetabular revision (dislocation in fourteen hips, 20%) and those in which both components had been revised (dislocation in eleven hips, 8%; p = 0.03), but there was no difference in component survival if a dislocation occurred. There was a significant association between a patient weight of >82 kg and acetabular failure (p = 0.04). CONCLUSIONS: This titanium-fiber-metal-coated hemispheric component fixed with multiple screws had a twelve-year survival rate of 95% when used in an unselected, consecutive series of acetabular revisions. The rate of dislocation was significantly higher in the patients treated with isolated acetabular revision, and routine postoperative bracing is now recommended for that group.  相似文献   

6.
One hundred nineteen consecutive primary hybrid total hip arthroplasties with a precoated femoral component were performed by one surgeon in 100 patients and followed up prospectively. Ninety-eight hips in 82 patients (mean age, 67 years) were evaluated clinically and radiographically at a mean of 6.5 years (range, 5-9 years). The hips were evaluated clinically using the Harris hip score, and radiographs were evaluated for femoral cement grade, loosening, and osteolysis. Ninety-five hips remained in place at the most recent followup. Two femoral components were revised for definite loosening, and one well fixed femoral component was removed because of late hematogenous infection. Excluding the three hips that were revised, the clinical result was excellent or good in 79 hips (83%), fair in 12 hips (13%), and poor in four hips (4%). All other femoral components were well fixed. There were defects of the cement mantles (C1 and C2) in 90 hips. No femoral component had a stem and cement radiolucent line. Focal femoral osteolysis was seen in only two hips. One acetabular component was removed at 5 years because of late hematogenous infection. One acetabular component had asymptomatic migration. The remaining 96 acetabular components were well fixed. Focal acetabular osteolysis was present in four hips. The mean linear polyethylene wear rate was 0.06 (+/- 0.05) mm per year. In contrast to other reports of early failure and osteolysis, the use of a precoated femoral component in this study did not adversely affect the fixation of hybrid total hip arthroplasty, with definite failure of only 2% (two of 98) of the femoral components.  相似文献   

7.
Between 1974 and 1982, 132 consecutive hips in 112 patients >75 years of age were treated with primary total hip arthroplasty for osteoarthritis using a cemented all-polyethylene T28 socket and cemented T28 or TR28 stem with a 28-mm head size. At the time of review, 94 patients (110 hips [83%]) had died and 18 patients (22 hips [17%]) were still living (mean age at follow-up, 93 years). Five hips (5 patients) were lost to follow-up. Clinical follow-up averaged 8.9 years for the entire group and 14.6 years for patients still living. Only 2 acetabular components have been revised (1 for recurrent dislocation, 1 for infection). No acetabular component has required revision for aseptic loosening. Survivorship free of acetabular revision for aseptic loosening at 10 years was 100%; free of symptomatic acetabular loosening, 97.4% (95% confidence interval, 91.8-100%); and free of acetabular loosening, 95.9% (95% confidence interval, 89.7-100%). The commonest complication was postoperative hip dislocation, which occurred in 11 hips (8.7%) and which required reoperation in 2 hips. Cemented acetabular components implanted in patients >75 years of age with a diagnosis of osteoarthritis showed a high rate of survivorship free of revision and free of symptomatic aseptic loosening.  相似文献   

8.
9.
Fifteen-year clinical survivorship of Harris-Galante total hip arthroplasty   总被引:5,自引:0,他引:5  
We studied the long-term outcome of uncemented total hip arthroplasty using HG-I components in 90 hips (80 patients) with an average age of 57.5 years who were operated on between 1984 and 1986 at our institution. Average follow-up was 14.9 years, and no patient was lost to follow-up. Hip scores improved significantly, and there was clinical and radiographic evidence of bony ingrowth on the acetabular components in all patients. There were 11 revisions in the study population for reasons related to failure of the femoral component (8 hips), acetabular liner dissociation (2 hips), and deep infection (1 hip). At the latest follow-up, 3 femoral components were determined to be loose. No acetabular component was revised for aseptic loosening. In addition to the revisions, there were 2 reoperations, 1 for psoas tendon release, and 1 for excision of heterotopic ossification. Thus, the survivorship free of revision and free of mechanical failure for the acetabular component at 15 years was 95.7% (95% confidence interval [CI], 0.89-1.0) and 91.9% (95% CI, 0.83-0.98), respectively. The survivorship at 15 years for the femoral component was 86.8% (95% CI, 0.78-0.95) free of revision and 82.0% (95% CI, 0.71-0.92) free of mechanical failure.  相似文献   

10.
BACKGROUND: Use of modern cementing techniques for fixation of femoral components in total hip arthroplasty has had excellent clinical and radiographic results in most patients. However, several authors have described early loosening of femoral components with roughened and precoated finishes. The purpose of this study was to examine the performance of the precoated Iowa stem, which has increased offset, and to compare the results with those of another cemented precoated femoral component with standard offset used at our institution. METHODS: We carried out a prospective analysis of 102 primary hybrid total hip arthroplasties (a cementless acetabular component and a cemented femoral component) performed with use of the Iowa femoral component in ninety-five patients at our institution. The Iowa stem was used in hips that required greater offset than is available with standard stems as determined by preoperative templating. The average age of the patients at the time of the index procedure was sixty-nine years. Sixteen patients (seventeen hips) died before the forty-eight-month minimum follow-up period had elapsed. Two patients were lost to follow-up, and radiographic follow-up was incomplete for one. The mean duration of clinical and radiographic follow-up of the remaining eighty-two hips in the seventy-six surviving patients was sixty-five months (range, forty-eight to 104 months). RESULTS: The average preoperative Harris hip score of 47 points (range, 16 to 69 points) improved to an average of 87 points (range, 24 to 100 points) at the time of the review. Two hips underwent femoral component revision. Four femoral stems were radiographically loose at an average of thirty-four months. Femoral osteolysis was seen in five hips (6 percent) at an average of fifty-four months postoperatively. No acetabular component was revised because of aseptic loosening. According to Kaplan-Meier analysis, the seven-year survival rate, with an end point of femoral revision, osteolysis, or stem debonding, was 90.6 percent (95 percent confidence interval, 0.87 to 0.94). CONCLUSIONS: The prevalence of revision, osteolysis, and loosening after total hip arthroplasty with the Iowa femoral component at our institution was higher than that seen in our series of Harris Precoat stems, which had a survival rate of 98.4 percent (95 percent confidence interval, 0.97 to 1.00) at ten years with the same end points. The design of the Iowa stem may make it difficult to achieve a good cement mantle, and, in combination with the geometry and increased offset of the stem, may compromise the long-term survival of this cemented femoral component.  相似文献   

11.
BACKGROUND: Various studies have reported good long-term results using femoral stems with either smooth or rough surfaces. In this retrospective cross-sectional survivorship study, we reviewed the 10-year results of 51 bilateral staged cemented total hip arthroplasties using the Harvard or the Charnley femoral stems-which have almost similar geometry but a different surface finish. METHODS: 51 patients were reviewed at median interval of 10 (Harvard group) and 11 years (Charnley group) after the primary operation. We evaluated cement mantle thickness, alignment of the components, presence of radiolucent lines, and aseptic loosening. Kaplan-Meier analysis was performed to calculate the survival rate using various endpoints. RESULTS: 8 hips in the Harvard group were revised for aseptic loosening of the femoral component at a median interval of 6.3 years after the primary procedure. 3 hips in the Charnley group were revised for aseptic loosening of the femoral and acetabular components between 10 and 11 years after the primary procedure. The 10-year survival rate for the femoral component using revision surgery for aseptic loosening as an endpoint was 80% (95% CI: 31-42) and 95% (95% CI: 44-47) in the Harvard and the Charnley group, respectively. Cox regression analysis did not reveal any statistically significant effect of various radiographical parameters on the survival rate (p < 0.05). INTERPRETATION: Our results demonstrate that in the group of patients studied, the femoral stem component with the matt surface finish had less satisfactory 10-year survival than the femoral stem of similar design which had a smooth surface finish.  相似文献   

12.
We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral alignment. The mean follow-up was for 11.7 years. Femoral loosening was demonstrable radiologically in 15 hips (8.1%), ten (5.4%) of which were revised during the period of follow-up. Only when the first postoperative radiograph showed a thin cement mantle in Gruen zone 5 was there a significant association with failure of the femoral component. There were 12 loose acetabular components (6.5%), nine (4.8%) of which were revised. When the initial radiograph after operation showed radiolucency in DeLee and Charnley zone 1, the incidence of acetabular loosening was 28.21%. If such radiolucency was not present, the incidence of acetabular loosening was only 0.69%. Our findings emphasise the importance of careful cementing.  相似文献   

13.
Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only three femoral components had definitely loosened, none were probably loose and 24 were graded as possibly loose. In contrast, the incidence of radiographic loosening on the acetabular side was 42%. Improved cementing techniques have produced a marked reduction in the rate of aseptic loosening of the femoral component, but the incidence of acetabular loosening is unchanged.  相似文献   

14.
Seventy-three patients (84 hips) 50 years or younger were treated with primary total hip arthroplasty using the Harris-Galante uncemented acetabular component. At a median followup of 10 years, there were seven acetabular metal shell revisions: five for osteolysis and one each for aseptic loosening and dislocation. There were 10 polyethylene exchanges without metal acetabular shell removal. None of the unrevised acetabular components was radiographically loose, but eight had pelvic osteolysis. The rate of 10-year survival without revision of the acetabular metal shell was 87.9% (95% confidence interval, 80.1%-95.7%). The same rate of survival without revision for aseptic acetabular component loosening was 97.3% (95% confidence interval, 92.9%-100%). Revision for aseptic acetabular loosening or polyethylene liner exchange or both was 84.5% (95% confidence interval, 75.8%-93.4%).  相似文献   

15.
One hundred twenty-three consecutive primary total hip arthroplasties in 107 patients were performed with the insertion of a cemented, all polyethylene, flanged acetabular component. At a minimum of 20 years, 66 patients had died (75 hips) and 8 patients (8 hips) were lost to follow-up evaluation, leaving 40 hips in 33 patients. At a mean of 21.1 years, 2 cups had been revised for aseptic loosening, one well-fixed cup was revised at the time of femoral component revision, and 4 additional cups had definite evidence of radiographic loosening. Survivorship analysis revealed a 77.3% survivorship for the component at 21 years, with revision or definite loosening as an endpoint (95% confidence interval, 67.8%-86.8%).  相似文献   

16.
In a prospective study, 93 unselected consecutive uncemented hip arthroplasties were performed in 80 patients using the titanium-coated RM acetabular component and the CLS femoral component. The mean age of the patients at operation was 52 years (28 to 81). None were lost to follow-up. In the 23 patients who had died (26 hips) only one acetabular component had been revised. In the 57 living patients (67 hips), 13 such revisions had been performed. Of the 14 revisions, seven were for osteolysis, five for loosening and two for infection. Survival analysis of this implant showed a total probability of survival of 83% (95% confidence interval 73 to 90), with all revisions as the endpoint, and a probability of 94% (95% confidence interval 87 to 98) with revision for aseptic loosening as the endpoint, indicating reliable long-term fixation of the titanium-coated RM acetabular component.  相似文献   

17.
The clinical and radiographic results of primary cemented total hip arthroplasty performed by a single surgeon, with particular emphasis on the performance of acetabular components implanted with so-called second-generation cement techniques, were studied. Seventy hips with 48 metal-backed and 22 polyethylene acetabular components were followed for a mean of 9 years (range, 5–11.5 years). The clinical results were evaluated using a recognized hip score. The fixation status of the cemented acetabular component was evaluated using two methods of measuring radiolucent lines at 5 years and at the last evaluation. Acetabular component loosening was defined as a circumferential radiolucent line, component migration, or revision for loosening. This study was unable to confirm the findings of others that demonstrated higher failure rates with cemented metal-backed components when compared with all-polyethylene components. The survival of cemented acetabular components with 28-mm head femoral prostheses was worse than the survival of cemented acetabular components with 22-mm femoral heads in other published reports, despite advances in cement techniques. Because of the high rate of loosening of cemented 28-mm-inner-diameter acetabular components at 5 and 10 years, the authors no longer use these cemented components for acetabular reconstruction.  相似文献   

18.
We report the updated results for a previously evaluated cohort of patients who were less than fifty years old when they underwent Charnley total hip arthroplasty with cement. The original cohort consisted of ninety-three total hip arthroplasties performed in sixty-nine patients. The patients were followed for a minimum of twenty-five years after surgery or until death. The present report describes the findings of the radiographic and functional follow-up, which was performed for forty-two of the forty-three living patients. At the time of the latest follow-up, twenty-nine (31%) of the ninety-three total hip replacements had been revised or removed. Eighteen acetabular and five femoral components were revised secondary to aseptic loosening. The combined prevalence of radiographic failure or revision because of aseptic loosening was 13% for the femoral components and 34% for the acetabular components. Comorbid medical conditions significantly hindered results on each functional subscale (p < 0.05). This study demonstrates the durability of cemented total hip replacements in a young patient population. Sixty-nine percent of the original hip replacements were functioning well at the latest follow-up examination or at the time of death, and only 5% required more than one revision arthroplasty.  相似文献   

19.
We previously evaluated a cohort of fifty-three patients with severe hip dysplasia (Crowe Type-II, III, or IV subluxation) who underwent a total of sixty-six Charnley total hip arthroplasties. The acetabular component was placed at the anatomic hip center, the superolateral defect was filled with cement, and no bone-grafting was used to supplement the acetabular wall. All but one patient, who was lost to follow-up, were followed until death or for a minimum of twenty years. Radiographic and functional follow-up data were collected prospectively. This retrospective review included twenty-four patients (thirty-four hips) who were alive at a minimum of twenty years following the surgery. Fourteen (22%) of the sixty-five hips underwent revision of a component, with eleven of the revisions performed because of aseptic loosening. Eight of those eleven hips underwent revision because of acetabular loosening alone; two, because of femoral loosening alone; and one, because of loosening of both components. The combined prevalence of revision because of aseptic loosening of the acetabular component and radiographic evidence of failure of the acetabular component was 28% (eighteen hips). With the numbers available, the need for acetabular revision was not associated with the percentage of cement coverage (p = 0.362) or the Crowe classification (p = 0.159). At a minimum of twenty years postoperatively, the survivorship of the acetabular component was 86% +/- 8% with revision because of aseptic loosening as the end point and 82% +/- 10% with revision because of aseptic loosening or radiographic evidence of loosening as the end point. The results that we evaluated at a minimum of twenty years after use of this technique can be compared with the results of other techniques in studies with similar long-term follow-up periods.  相似文献   

20.
《The Journal of arthroplasty》2022,37(8):1612-1617
BackgroundThe long-term failure modes of total hip arthroplasty (THA) in adult patients who had childhood infection have not been documented. The purpose of this study is to analyze the longer term clinical and radiographic results, prevalence of osteolysis, and survival rate of THA.MethodsWe reviewed the results of 142 patients (145 hips) (mean age 41.9 years). The age of the patients at the time that the infection was contracted was an average of 7.1 years (range 1-11). The average interval between active infection and THA was 34.5 years. All but 2 hips (1 patient) had a quiescent period of infection of more than 10 years. The average duration of follow-up after THA was 31.5 years (range 25-38).ResultsAll but 2 hips with more than 10 years of quiescent infection had no recurrence of infection. The remaining 2 hips in the 1 patient with only 7 years of quiescent infection had a recurrence of infection. Seventy-eight of 145 hips (54%) underwent isolated cup revision for loosening, or osteolysis, or dislocation. Thirty (21%) femoral components were revised for aseptic loosening and/or osteolysis. The Kaplan-Meier survivorship curve at 31.5 years showed that the survival rate of the acetabular component was 46% (95% confidence interval 39-74) and that of the femoral component was 79% (95% confidence interval 73-89).ConclusionContributing factors to the high failure rate of THAs were less than optimal prostheses and poor quality of polyethylene during the time period of this study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号