共查询到20条相似文献,搜索用时 31 毫秒
1.
Introduction
Distal femoral fractures have many of the same challenges as hip fractures, but there has been limited research into outcomes following these. The aim of this study was to assess 30 day mortality following distal femoral fractures in comparison to hip fractures presenting to a single institution Secondary outcomes included risk factors for mortality, post-operative complications and union.Methods
A retrospective case series of all distal femoral fragility fractures in patients over 65, and hip fractures over a 5?year period at a single institution.Results
88 distal femoral fractures and 2837 hip fractures fulfilled the inclusion criteria. In the distal femoral fractures there were 80 females and 8 males with a mean age of 82.4 (range 65–103). The mean age of the hip fractures was 83.7 (range 65–106) and there were 2066 females and 771 males.The overall 30 day mortality for hip fractures was 7.7% and was 9.1% for distal femoral fractures. The risk ratio was 1.1777(95% CI 0.6009–2.3080) (p?=?0.6338). There was no significant difference in 30 day mortality between the two fracture types.Of the 88 distal femoral fractures 75 (85.2%) underwent open reduction internal fixation, 5 (5.7%) intramedullary nail and 8 (9.1%) conservative treatment. 11.4% suffered a medical complication. 9.1% patients required at least 1 further surgical procedure. The union rate was 94.3%. The 1?year mortality was 34.1%.Conclusions
There is no significant difference in 30 day mortality between distal femoral and hip fractures. Distal femoral fractures occur in a complex group of patients that is similar to hip fractures. They have high mortality and complication rates. 相似文献2.
Joey P. Johnson Justin Kleiner Avi D. Goodman Joseph A. Gil Alan H. Daniels Roman A. Hayda 《Injury》2019,50(3):708-712
Introduction
Young patients with femoral neck fractures are optimally treated with reduction and stable fixation, while patients over the age of sixty-five are often treated with arthroplasty. This study analyzes in-hospital outcomes associated with total hip arthroplasty, hip hemiarthroplasty and internal fixation for treatment of femoral neck fractures in patients aged 45–64.Methods
Records of patients between the ages of 45–64, from 2002 to 2014, sustaining femoral neck fractures and treated with internal fixation, hip hemiarthroplasty or total hip arthroplasty were obtained from the Nationwide Inpatient Sample (NIS). Examined variables were age, sex and Charlson Comorbidity Index (CCI). Outcome measures included hospital length of stay (LOS), complications, and inpatient hospitalization charge.Results
From 2002–2014 74,678 femoral neck fractures were available for analysis. THA use increased from 5.3% of operatively managed fractures in 2002 to 22.3% of operatively managed fractures in 2014 (p?<?0.0001). Patients undergoing THA had higher hospital cost, higher in hospital complication rates and longer length of stay than patients undergoing internal fixation (p?<?0.0001). The in-hospital mortality for patients undergoing a hip hemiarthroplasty was higher (1.2%) than either total hip arthroplasty (0.2%) or internal fixation (0.5%) (P?=?0.007).Conclusion
This study demonstrates that the use of total hip arthroplasty in treatment of femoral neck fractures in patients from the age of 45–64 increased 4.2-fold over the study period. This treatment is associated with increased hospital cost, length of stay and complications. Additionally, as age increased in our study population, there was a stepwise increase in the use of arthroplasty, and it appears that hemiarthroplasty is being used with a different patient population. 相似文献3.
Nam Hoon Moon Won Chul Shin Jung Shin Kim Seung Hun Woo Seung Min Son Kuen Tak Suh 《Injury》2019,50(3):713-719
Background
The aim of this study was to investigate the postoperative outcomes of cementless Total hip arthroplasty (THA) following failed internal fixation for femoral neck and intertrochanteric fractures.Method
Ninety-six cementless THAs for failed internal fixation after femoral neck fracture (59, group I) and intertrochanteric fracture (37, group II) with a minimum follow-up of 3 years were analyzed. Clinical and radiologic evaluations were performed on all patients.Results
The intraoperative blood loss and operating time were significantly increased in group II (p?=?0.001, p?=?0.001, respectively). Harris hip score at last follow-up was significantly improved in group I (p?=?0.007) but, there were no differences in hospital stay, Koval score at last follow-up, and perioperative complications between both groups. Long femoral stems for diaphyseal fitting were frequently used in group II (32/37, 86%) (p?=?0.001). Radiographically, none of the acetabular cups showed evidence of migration, loosening. All cases showed stable fixation of the femoral stem at last follow-up.Conclusions
Outcomes of cementless THA following failed internal fixation for femoral neck and intertrochanteric fractures were satisfactory; increased intraoperative blood loss, operating time, and requirement of long femoral stem should be considered in the latter type of fracture. 相似文献4.
Objectives
Iatrogenic injury of the Profunda Femoris Artery (PFA) at time of hip fixation surgery can increase morbidity and mortality and prolong the hospital stay. This is an injury that tends to pass unnoticed as a cause of postoperative deterioration despite being frequently reported in the literature. Our study aims to describe the anatomy of the PFA in relation to the medial femoral cortex with specific emphasis on its orientation relative to the position of a sliding hip screw side plate construct. By doing so we are able to present clear guidance to orthopaedic surgeons on how to avoid iatrogenic PFA injury at the time of hip fracture fixation.Methods
Using Computed Tomography Angiographic (CTA) studies, the course of the PFA in relation to the medial femoral cortex was traced in 44 patients (28 males and 16 females) with mean age of 65.6 years. Coronal and axial CT sections were cross-linked to specify the position of the PFA at 1?cm intervals.Results
The course of the artery could be divided into three parts relative to a fixed reference point. Proximal and distal parts of the artery were in a safer position in comparison to the middle part of the artery that was found very close to the femoral cortex and along the coronal axis of the femur (mean angle 2.9° from the femoral coronal axis and 13.8?mm from the medial femoral cortex). Using the commercially available side plate constructs, this part of the artery corresponded to the distal part of the plate (third and fourth holes).Conclusion
Special attention needs to be practiced by the operating surgeon while drilling into the third and fourth holes of the side plate. 相似文献5.
Ahmed Latif Baljinder S. Dhinsa Benjamin Lau Ali Abbasian 《Foot and Ankle Surgery》2019,25(2):132-136
Background
This study reports the outcome of a plating system for arthrodesis of the first metatarsophalangeal joint (1st MTPJ) that incorporates a lag compression screw within a low profile titanium plate with a predetermined contour. This is the first report of the outcomes of this implant from a non-affiliated centre.Patient and methods
This is a prospective cohort study of 40 consecutive primary 1st MTPJ arthrodesis procedures. The mean age of the cohort was 56 years (range, 20–74 years). The diagnosis was hallux rigidus in 31 patients and inflammatory arthropathy in 7 patients.Results
All patients achieved clinical union at 6 weeks and radiological union was confirmed on plain radiographs between 6–16 weeks. One case of hardware removal was reported.Conclusion
The cohort achieved consistently satisfactory results with a reliable and reproducible MTPJ position and a 100% union rate. There was a low rate of hardware removal.Level of evidence
Level IV evidence. Prospective cohort study. 相似文献6.
Christina Marie Joseph Chandrasekaran Gunasekaran Abel Livingston Hepsy Chelliah Thilak Samuel Jepegnanam P.R.J.V.C. Boopalan 《Injury》2019,50(3):784-789
Background
Contrary to acute posterior cruciate ligament (PCL) bony tibial avulsions, surgical management of chronic injuries is technically challenging and appears to be controversial. We sought to assess the outcome of a novel screw post augmentation technique in neglected cases.Methods
16 patients were followed up in a tertiary single-center retrospective study. The bony fragment was fixed using a lag screw with a spiked washer and an additional screw post through an open posterior approach. The pre- and postoperative knee range of movement (ROM), laxity, and modified Tegner–Lysholm (TL) scores were compared.Results
The median time from injury to surgery was 10 weeks (range, 3–260). The mean clinical follow-up time was 24.25?±?9.21 months. At the final follow-up, the mean knee ROM flexion was 130°?±?11.55° with no extension lag. 3 patients had grade 1 laxity. The TL grade was predominantly excellent, and the overall median score improved from 76 preoperatively to 95 postoperatively (p?<?0.0004). Bony union was achieved in all cases.Conclusion
The described screw post fixation technique results in an excellent outcome for these rare injuries.Level of evidence
Level IV, case series. 相似文献7.
Jan Herzog Robert Wendlandt Sebastian Hillbricht Rainer Burgkart Arndt-Peter Schulz 《Injury》2019,50(3):744-751
Introduction
The annual incidence of proximal femoral fractures is 100–150/100,000 and continues to increase with an aging population. Cut-out of hip screws after fracture fixation has been quoted as 8% in the literature. The tip-apex distance (TAD) is the strongest predictor for cut-out after operative fracture stabilisation.The aim of this study was to evaluate the novel ADAPT system (Adaptive Positioning Technology, Stryker, USA), a navigation device for intramedullary nailing of trochanteric fractures and its effect on optimising the TAD. This is the first clinical study to evaluate this new technology.Methods
The study group of 36 consecutive patients with a pertrochanteric fracture underwent intramedullary nailing for fracture fixation using ADAPT technology, while the matched control group underwent conventional Gamma-3-nailing. Matching criteria included fracture classification, gender and age. We measured the operative time and the postoperative TAD in anteroposterior (AP) and lateral radiographs of the 72 patients.Results
The mean TAD using ADAPT was 16.9?mm (range 8.4–33.7?mm) compared with 24.9?mm (range 14.6–40.2?mm) in the reference group treated without ADAPT. Using the ADAPT system significantly improved (p?<?0.0005) the accuracy of lag screw placement but had no effect on operating time in fixation of femoral pertrochanteric fractures.Conclusion
Working with the novel ADAPT system for positioning the lag screw using the Gamma-3-nail led to a statistically highly significant reduction of the TAD compared to the reference group (p?<?0.001). The ADAPT system proved to be a very useful device in achieving higher surgical standards for the treatment of trochanteric fractures with intramedullary nailing. It enables higher accuracy in screw positioning and therefore better placement of the implant. 相似文献8.
Jordi Salvador Samer Amhaz-Escanlar Pablo Castillón Iban Clares Saioa Quintas Martí Bernaus Francesc Anglés Alberto Jorge-Mora 《Injury》2019,50(2):415-419
Purpose
Antegrade intramedullary nailing is an alternative for humeral shaft fracture treatment. This surgical technique can be especially demanding in some fracture patterns, leading to problems like malunion and non-union. The purpose of our study is to demonstrate that the use of a nail with cerclage wires could be a safe procedure that facilitate reduction, specially in fractures with abduction of the proximal fragment.Materials and methods
Fifty-six patients were included, from January 2007 to March 2016. In this cohort forty-two patients were females and eighteen males; mean age was sixty-seven (32–89). The fractures were reduced using a cerclage wire through a small lateral or anterior approach, then, antegrade intramedullary nailing was performed. Fracture healing was established by clinical and radiographic evaluation. Shoulder function was assessed using the Constant Score.Results
Fifty-three patients healed (94.6%) adequately. Two patients developed a non-union (3.5%). One patient developed an infection (1.8%). Transient radial nerve palsy was observed in two patients (3.5%). The mean Constant Score at the end of the study was 70 points (range from 34 to 98 points).Conclusions
Surgical treatment of humeral shaft fractures with cerclage wire and intramedullary nailing is a safe technique to improve fracture reduction. The use of cerclage wires leads to better bone contact while minimizing malunions. The rate of non-union in our study is lower than the rate reported in the literature for humeral shaft fractures treated by intramedullary nailing alone. 相似文献9.
Matthew R. Walker Ashraf N. El Naga Omar H. Atassi Christopher H. Perkins Scott A. Mitchell 《Injury》2019,50(3):686-689
Objectives
Hip dislocations are highly morbid injuries necessitating prompt reduction and post-reduction assessment for fracture and incarcerated fragments. Recent literature has questioned the need for initial pelvic radiographs for acute trauma patients, resulting in computed tomography (CT) scans as the initial evaluation. This study investigates the relationship between choice of pre-reduction imaging and treatment of acute hip dislocations.Design
Retrospective Case-Control.Setting
Single Academic Level I Trauma Center.Methods
All acute hip dislocations from 2011 to 2016 were reviewed. Exclusion criteria were diagnosis of dislocation at another facility, death prior to reduction, emergent surgical or ICU intervention, and periprosthetic dislocation. Patients were grouped by those with only a radiograph prior to reduction, Group I, versus those with a pre-reduction CT scan, Group II. The primary outcomes were time to reduction and the acquisition of a second CT scan.Results
Of the 123 hip dislocations identified, 35 patients were excluded, mostly for transfer with a known dislocation. Group I included 29 patients and Group II included 59 patients. The mean time to reduction was 74?min in Group I and 129?min in Group II for a difference of 55?min (p?<?0.001). The rate of repeat CT scan was 0 in Group I versus 48 (81%) in Group II (p?<?0.001).Conclusion
Initial trauma pelvic radiography prior to CT is still important in the setting of suspected hip pathology to decrease time to hip reduction and unnecessary radiation exposure.Level of evidence
Prognostic Level III. 相似文献10.
Objective
To analyse whether early post-operative full weight bearing following syndesmotic ankle fixation affected radiographic outcomes suggestive of diastasis.Design
Retrospective comparative cohort study over a two year period.Setting
Level 1 trauma centrePatients/Participants
152 consecutive patients sustaining an unstable ankle fracture requiring syndesmotic stabilisation were included. Exclusions were 49 patients who had trimalleolar fixation without syndesmosis screws, one patient who had concomitant ankle and talar fracture. Five patients were lost to follow up and eleven patients were followed up in other centres. A total of 86 patients were analysedIntervention
Protected or full weight bearing.Main Outcome Measurement
The primary outcome measure was early diastasis. The secondary outcomes were late diastasis, wound complications and re-operation. Analysis of variance was used for the predictor variable of weight bearing status. We assumed a priori that p values of less than 0.05 were significant.Results
Median age was 36 (IQR 30), with 54 males and 32 females. Median follow up was 12 weeks (IQR 6). There was no significant difference when comparing weight bearing status and change in radiographic measurements intra-operatively compared to 6 and 12 week follow up radiographs (tibiofibular clear space p?=?0.799, tibiofibular overlap p?=?0.733 and medial clear space p?=?0.261).Conclusion
After surgical stabilization of an unstable syndesmotic injury, full weight bearing did not lead to syndesmotic diastasis in the early post-operative period. Full weight bearing is recommended following ankle fixation which includes syndesmotic fixation. 相似文献11.
Matthias Knobe Sebastian Bettag Christian Kammerlander Simon Altgassen Klaus-Jürgen Maier Sven Nebelung Andreas Prescher Klemens Horst Miguel Pishnamaz Christian Herren Marion Mundt Marcus Stoffel Bernd Markert Boyko Gueorguiev 《Injury》2019,50(2):292-300
Objectives
Improved fixation techniques with optional use of bone cements for implant augmentation have been developed to enhance stability and reduce complication rates after osteosynthesis of femoral neck fractures. This biomechanical study aimed to evaluate the effect of cement augmentation on implant anchorage and overall performance of screw-anchor fixation systems in unstable femoral neck fractures.Methods
Ten pairs of human cadaveric femora were used to create standardized femoral neck fractures (Pauwels type 3 fractures; AO/OTA 31-B2) with comminution and were fixed by means of a rotationally stable screw-anchor (RoSA) system. The specimens were assigned pairwise to two groups and either augmented with PMMA-based cement (Group 1, augmented) or left without such augmentation (Group 2, control).Biomechanical testing, simulating physiological loading at four distinct load levels, was performed over 10.000 cycles for each level with the use of a multidimensional force-transducer system. Data was analysed by means of motion tracking.Results
Stiffness, femoral head rotation, implant migration, femoral neck shortening, and failure load did not differ significantly between the two groups (p?≥?.10). For both groups, the main failure type was dislocation in the frontal plane with consecutive varus collapse). In the cement-augmented specimens, implant migration and femoral neck shortening were significantly dependent on bone mineral density (BMD), with higher values in osteoporotic bones. There was a correlation between failure load and BMD in cement-augmented specimens.Conclusion
In screw-anchor fixation of unstable femoral neck fractures, bone-cement augmentation seems to show no additional advantages in regard to stiffness, rotational stability, implant migration, resistance to fracture displacement, femoral neck shortening or failure load. 相似文献12.
Bahman SahraNavard Parke W. Hudson Cesar de Cesar Netto Bradley W. Wills Ibukunoluwa B. Araoye Shelby Bergstresser Brent M. Cone Ashish Shah 《Foot and Ankle Surgery》2019,25(1):84-89
Background
The number of screws used for sliding calcaneal osteotomy fixation has not been examined in the literature. The purpose of this paper is to examine this topic.Methods
Retrospective chart review was performed on 190 patients who met selection criteria. We compared complication risk for single versus double screw, headed versus headless screw, and short versus longitudinal incision cases.Results
The mean age was 48.4 (18–83) years and average follow up was 28 (12–150) weeks. All cases achieved radiographic union. Overall complication rate was 19.5% (37/190). Risk of complication did not differ significantly between single and double screw (RR: 1.170; 95% CI: 0.66–2.09; p = 0.594) or short and extended incision groups (RR: 0.868; 95% CI: 0.42–1.80; p = 0.704). Risk of complication differed significantly between headed and headless screw fixation (RR: 5.558; 95% CI: 2.69–11.50; p < 0.0001).Conclusions
Single screw fixation of sliding calcaneal osteotomy achieves similar outcomes as double screw fixation. Headless screws are advantageous for minimizing hardware pain and subsequent hardware removal. 相似文献13.
BaiHang Chen Chao Chen ZeTian Yang PeiZhen Huang Hang Dong ZhanPeng Zeng 《Foot and Ankle Surgery》2019,25(1):63-70
Background
To compare the efficacy between fixation with suture-button and screw in the treatment of syndesmotic injuries: a meta-analysis.Methods
We comprehensively searched PubMed, Embase, and the Cochrane Library and performed a meta-analysis of randomized controlled trials (RCTs) and retrospective comparative studies (RTCs). We performed using Review Manager 5.2.Results
Three RCTs and six retrospective studies were conducted, including a total of 397 patients. The significant differences of the fixation of suture-button were reported for AOFAS scores (at 3, 6 and 12 months follow-up), full-weight time, reoperation, malreduction and the rate of failure of fixation. There were no significant differences between the groups regarding complications of infection, VAS, OMAS, range of motion, TFCS, TFO and MCS.Conclusions
Neither the functional outcome nor complications significantly differed between the fixation methods, but suture-button might lead to a quicker return to work. This analysis needs to be confirmed and updated by larger sample data and rigorously designed RCTs. 相似文献14.
Ibukunoluwa B. Araoye Yvonne E. Chodaba Kenneth S. Smith Ryan W. Hadden Ashish B. Shah 《Foot and Ankle Surgery》2019,25(1):2-7
Background
Current literature on carbon fiber implant use in foot and ankle surgery is scant. The purpose of this paper is to report medium-term outcomes of hindfoot fusion using a carbon fiber intramedullary nail.Methods
We retrospectively reviewed 30 cases of hindfoot fusion using carbon fiber intramedullary nail fixation between 2014 and 2017. We excluded revisions and cases with bulk allograft or ankle infection prior to surgery. We reviewed charts for length of followup, radiographic union, and complications.Results
Eleven patients were included (6 females, 5 males; mean age = 52 ± 15 years; mean BMI = 29.0 ± 6.4 kg/m2). Mean followup was 20 (range, 1.5–107) months. Nine of eleven cases achieved radiographic union while one case developed a complication requiring surgery. The mean time to union was 3 (range, 1.5–6) months.Conclusions
Carbon fiber implants offer several theoretical advantages over traditional metallic implants. They can be used safely in foot and ankle surgery without concern for high failure or complication rate. Larger scale studies with longer followup are needed on this topic. 相似文献15.
Background
Few methods have been described for measuring hindfoot alignment from an anteroposterior view. The objective of this study was to compare two methods of angular measurement based on the views of Meary and Saltzman.Methods
Thirty asymptomatic volunteers were included. Four radiographs were performed: the views of Meary and Saltzman with parallel feet and with the Fick correction. The reproducibility was determined by the inter- and intraobserver variability (ICC).Results
Meary’s method revealed a mean valgus angulation of 3.9° (SD 3.47°). The reliability was extremely variable with a mean ICC of 0.59. The best reproducibility was obtained with Meary’s method with and without Fick correction.Conclusion
The results of this study show that the reliability of the angular measurements depends on the radiographic view and measurement method chosen. The lateral Fick correction did not counteract the influence of tibial rotation. The same method should be used consistently. 相似文献16.
Tero T. Yli-Kyyny Reijo Sund Mikko Heinänen Antti Malmivaara Heikki Kröger 《Injury》2019,50(2):403-408
Introduction
Hip fracture surgery is associated with a considerable amount medical and surgical complications, which adversely impacts the patient’s outcome and/or increases costs. We evaluated what risk factors were associated with the occurrence of early readmission due to surgical complications after hip fracture surgery.Material and methods
A nationwide database with 68,800 hip fracture patients treated between 1999 and 2011 was studied to uncover the association of readmissions with co-morbidities, fracture types, different hospital types and treatment methods using the Cox proportional hazards model.Results
Early readmission within three months due to hip fracture surgery complications occurred at a rate of 4.6%. Increased occurrence of readmission was found among patients with: heavy alcoholism (HR 1.38; 95% CI: 1.23–1.53); Parkinson’s disease (PD; HR 1.22; 95% CI: 1.05–1.42); pre-existing osteoarthritis (HR 2.02; 95% CI: 1.83–2.23); rheumatic disease (HR 1.44; 95% CI: 1.27–1.65); as well as those with a fracture of the femur neck, depression, presence of a psychotic disorder, an operative delay of at least three days, or previous treatment with total hip arthroplasty.Conclusion
Our results indicate that there are several factors associated with an increased risk of early readmission. We suggest that in the presence of these factors, the surgical treatment method and postoperative protocol should be carefully planned and performed. 相似文献17.
Alvin K. Shieh Motasem Refaat Nasser Heyrani Tanya C. Garcia-Nolen Mark A. Lee Jonathan G. Eastman 《Injury》2019,50(3):703-707
Objectives
Prophylactic femoral neck fixation may be performed in the setting of geriatric diaphyseal femur fracture, pathologic or impending atypical femur fractures. Fixation constructs often utilize cephalomedullary implants with one or two proximal interlocking screws into the femoral head/neck. Variations in proximal femoral anatomy and implant design can interfere with the placement of two screws in the femoral head and neck. Our objective was to assess the strength of piriformis entry reconstruction implants with one versus two proximal interlock screws for prophylactic femoral neck fixation.Methods
Thirty fourth generation synthetic femur models were separated into 5 groups. The control group was an intact femur, and the second group was an intact femur with an entry hole in the piriformis fossa. The remaining groups had an intramedullary nail placed with either 0, 1, or 2 screws placed into the femoral head and neck. Each femur was mechanically loaded along the mechanical axis through the femoral head. Load to failure and failure displacement were recorded.Results
Mean load to failure was 5583?±?543?N in the intact femur. Constructs with 2 screws had a significantly higher mean load to failure (3223?±?474?N) compared to one screw constructs (2368?±?280?N). All of the experimental groups remained significantly lower than the intact femur model (p?<?0.05).Conclusion
Our results demonstrate that piriformis entry reconstruction implants have a significantly lower load to failure compared to an intact femur irrespective of screw construct. Further studies are needed to investigate this potential iatrogenic weakening. 相似文献18.
Christina Liu Arvind Von Keudell Michael McTague Edward K. Rodriguez Michael J. Weaver 《Injury》2019,50(3):727-732
Background
It is common practice when placing cannulated screws within the femoral head when treating femoral neck fractures to avoid the thread-forms from crossing the fracture line. Despite the widespread use of cannulated screws in internal fixation of femoral neck fractures, there is no study to our knowledge that describes the ideal length of thread-forms.Purpose
The purpose of this study is to determine the thread length that will maximize purchase within the femoral head while minimizing risk of crossing the fracture line. Additional analysis was conducted to identify factors associated with the maximal possible length of treads in minimally and non-displaced femoral neck fractures.Methods
We performed a retrospective study of all patients treated for a minimally or non-displaced femoral neck fracture from April 1, 2004 through December 31, 2017. Only patients who had received a pre-operative CT or MRI scan were included. Fixation was then templated using radiographs and the distance from the subchondral bone to the fracture line was then measured.Results
The study included 127 patients. The average estimated length of lag screw threads was 33.2?±?6.67?mm, with lower quartile of 29.1?mm and higher quartile of 37.2?mm. The median was 32.0?mm and most frequently encountered estimate was 29?mm. Estimated lag screw size did not differ significantly based on age or BMI, but both height (p?<?0.001) and race (0.04) were positively correlated with estimated lag screw size and males had longer measurements compared to females, 37.2?±?7.0?mm vs 31.4?±?5.7?mm (p?<?0.001), respectively.Conclusion
In conclusion, we propose an additional lag screw thread form with length 26.0?mm to capture 90% of femoral neck fractures. 相似文献19.
Background and purpose
The treatment of paediatric distal radius diaphyseal metaphyseal junction (DRDMJ) fractures is a challenge. The purpose of this study was to introduce a new operative approach at the proximal “safe zone” of the posterior interosseous nerve (PIN) to treat paediatric DRDMJ fractures and analyse the safety and efficacy of antegrade elastic stable intramedullary nail (ESIN) fixation.Methods
Thirty paediatric patients with unstable and displaced DRDMJ fractures were treated by antegrade ESIN fixation from November 2015 to September 2017. We created the entrance site at the posterolateral side of the proximal radius and 2?4?cm distal to the articular surface of the radius, using the ESIN to immobilise the fractures. In the study, we reviewed patient demographics, complications, time until removal, and intraoperative time for hardware removal.Results
Complete fracture healing was achieved between 6 and 12 weeks after surgery. Except for 3 patients presenting with irritation of the skin, we did not observe any complications. Radiologically, no secondary displacement, nail migration, loss of fixation, consolidation delay, non-union, or refracture was noted.Conclusions
The antegrade ESIN fixation is a minimally invasive, easy-to-learn, alternative operative method to treat paediatric DRDMJ fractures.Level of evidence
Therapeutic Level IV. 相似文献20.
M.C. Liebensteiner B. Henninger C. Kittl R. Attal J.M. Giesinger C. Kranewitter 《Injury》2019,50(2):602-606