目的:通过比较不同管电流扫描情况下正常肝脏的灌注参数,评价低剂量肝脏CT灌注成像(CTPI)的可行性。方法:确诊无肝脏疾病的健康志愿者32例,随机分为3组,常规剂量组(140mA)、中等剂量组(90mA)和低剂量组(50mA)。比较两种兴趣区选择方式下各组所测量的肝脏灌注参数(HBF、HBV、HPI、MTT、PS、HAP及PVP)间的差异。结果:不同管电流扫描条件下肝脏CTPI均获得了较满意的图像质量及灌注参数,不同兴趣区选择方式下各灌注参数值间的差异无显著性意义(P〉0.05)。常规剂量组测量的HPI值(t=-2.23,P=0.034)和低剂量组测量的MTT值(t=-2.25,P=0.042)在不同感兴趣区选择方式间略有差异。常规剂量、中等剂量和低剂量肝脏CTPI的有效剂量分别为19.62mSv、12.61mSv和7.01mSv,低剂量CTPI较常规剂量减少约64.27%的辐射剂量。结论:低剂量肝脏CTPI可以较常规剂量减少约2/3的辐射剂量,同时获得与常规剂量CTPI相当的灌注参数结果。 相似文献
4.
5.
螺旋CT低剂量扫描在育龄男女骨盆病变中的应用研究 总被引:1,自引:0,他引:1
目的:探讨育龄男女骨盆在做低剂量扫描时合理剂量选择及其应用价值。方法:选择96例患者,每个研究对象均用常规剂量(210mA)扫描,在征得患者同意后,用低剂量(50mA,25mA)再加扫一层或几层,两种扫描模式除了后者用低剂量技术,前者不用外,其余扫描参数相同,比较权重CT剂量学指数及CT图像质量的差别。结果:25mA时CTDIvol最小,为常规剂量扫描的11%,但图像质量与常规剂量相比差异有高度显著性(P〈0.01);50mA时,CTDIvol为常规剂量扫描的22%,图像质量与常规剂量相比差异无显著性(P〉0.05)。结论:育龄男女骨盆低剂量(50mA)扫描既可保证骨盆部病变的影像质量,又可降低患者的辐射剂量。 相似文献
6.
目的:探讨优化临界心率采集方案对320排CT冠状动脉成像图像质量和辐射剂量的影响。方法:前瞻性收集2019年11月至2022年9月60例(呼吸训练屏气时平均心率为75~79次/min区间)行冠状动脉CT检查者,其中通过手动修改优化为1个心动周期采集者为A组(n=30),通过系统自动设置方案2个心动周期采集者为B组(n=30)。记录扫描前平静呼吸时心率(静息心率)、呼吸训练屏气时心率(基础心率)、注射对比剂扫描中的心率(注射时心率)、图像质量和辐射剂量指标进行统计学分析。结果:A组、B组静息心率分别为(78.3±3.9)次/min、(79.1±3.7)次/min,基础心率分别为(76.8±2.7)次/min、(77.3±2.9)次/min,注射时心率分别为(73.8±3.0)次/min、(74.4±2.5)次/min。注射时心率<基础心率<静息心率,A组注射时心率比基础心率平均下降约(3.0±0.7)次/min,B组平均下降约(2.9±0.2)次/min。A组、B组辐射剂量分别为(1.36±0.46)mSv、(2.79±0.52)mSv,差异有统计学意义(t=-2.961,P... 相似文献
7.
8.
郭晶 《航空航天医学杂志》2021,32(11):1300-1301
目的 浅析低剂量螺旋CT诊断应用于肺结节筛查中的效果.方法 纳入2020年6月~2021年6月行多层螺旋CT肺部扫描患者58例,分别行常规剂量与低剂量螺旋扫描.结果 低剂量CT检查辐射状况各项指标均低于常规剂量CT,差异有统计学意义(P<0.05),但图像质量与肺结节形态检出状况比较,差异无统计学意义(P>0.05).结论 低剂量螺旋CT可在保障检出质量的基础上,降低辐射剂量. 相似文献
9.
10.
《中国中西医结合影像学杂志》2018,(6)
目的:探讨256排CT运用全模型迭代重建算法(IMR)行极低剂量CT肺结节筛查的可行性,以降低肺结节筛查者的辐射剂量。方法:回顾性分析100例肺结节患者的胸部CT平扫图像数据,常规剂量组及极低剂量组各50例,对2组体质量指数(BMI)行正态分布检验。由2名放射科医师对每例患者的图像质量进行主观评分;测量气管分叉处右肺外周带CT值及其标准差,计算SNR,记录每次扫描的CTDIvol值。对2组图像质量主观评分、图像噪声、剂量长度乘积、有效剂量行两独立样本t检验。结果:100例CT图像均可满足诊断要求。2组图像质量的主观评分差异无统计学意义(P 0.05);与常规剂量扫描辐射剂量(6.33±0.54)mSv相比较,极低剂量扫描的有效剂量(1.04±0.37)mSv降低至常规扫描的16.4%;2组图像的CT值差异无统计学意义(P 0.05),噪声差异有统计学意义(P0.05)。结论:IMR的极低剂量肺结节筛查图像质量可满足诊断要求,受检者辐射剂量大幅降低。 相似文献
11.
目的 以仿真人体模型为实验对象,研究PET/CT中CT图像质量与辐射剂量的关系,为保证图像质量同时降低受检者的辐射剂量提供数据依据。方法 用美国GE Discovery ST型 PET/CT,对仿真人体模型(Model RS-550)进行扫描。CT采集条件:管电压120 kV,管电流30~250 mA范围内11种固定值及自动管电流,螺距(pitch)分别为0.938、1.375、1.75,模拟临床PET/CT的全身扫描方式对仿真人体模型进行扫描。对图像进行分析,计算腹部主要器官的噪声、信噪比及质量因数。结果 噪声随有效剂量的增加而降低,有效剂量<15 mSv时,噪声变化幅度较大;>15 mSv时,噪声变化缓慢。信噪比、对比信噪比随有效剂量增加而增加。相同的有效剂量时,质量因数与扫描方案相关。自动管电流模式下的所有指标,均优于固定管电流采集模式。结论在CT图像质量达到一定程度后,进一步增加有效剂量,图像质量提高有限。根据不同的临床需求在保证一定图像质量的前提下,选择适当的CT扫描方案,降低受检者的有效剂量。 相似文献
12.
13.
Kim BS Hwang IK Choi YW Namkung S Kim HC Hwang WC Choi KM Park JK Han TI Kang W 《Acta radiologica (Stockholm, Sweden : 1987)》2005,46(7):756-763
PURPOSE: To compare the efficacy of low-dose and standard-dose computed tomography (CT) for the diagnosis of ureteral stones. MATERIAL AND METHODS: Unenhanced helical CT was performed with both a standard dose (260 mAs, pitch 1.5) and a low dose (50 mAs, pitch 1.5) in 121 patients suspected of having acute renal colic. The two studies were prospectively and independently interpreted for the presence and location of ureteral stones, abnormalities unrelated to stone disease, identification of secondary signs, i.e. hydronephrosis and perinephric stranding, and tissue rim sign. The standard-dose CT images were interpreted by one reviewer and the low-dose CT images independently by two reviewers unaware of the standard-dose CT findings. The findings of the standard and low-dose CT scans were compared with the exact McNemar test. Interobserver agreements were assessed with kappa analysis. The effective radiation doses resulting from two different protocols were calculated by means of commercially available software to which the Monte-Carlo phantom model was given. RESULTS: The sensitivity, specificity, and accuracy of standard-dose CT for detecting ureteral stones were 99%, 93%, and 98%, respectively, whereas for the two reviewers the sensitivity of low-dose CT was 93% and 95%, specificity 86%, and accuracy 92% and 94%. We found no significant differences between standard-dose and low-dose CT in the sensitivity and specificity for diagnosing ureter stones (P >0.05 for both). However, the sensitivity of low-dose CT for detection of 19 stones less than or equal to 2 mm in diameter was 79% and 68%, respectively, for the two reviewers. Low-dose CT was comparable to standard-dose CT in visualizing hydronephrosis and the tissue rim sign. Perinephric stranding was far less clear on low-dose CT. Low-dose CT had the same diagnostic performance as standard-dose CT in diagnosing alternative diseases. Interobserver agreement between the two low-dose CT reviewers in the diagnosis of ureter stones and alternative diseases, the identification of secondary signs, and tissue rim sign were high, with kappa values ranging from 0.769 to 0.968. On standard-dose CT scans, the calculated mean effective radiation dose was 7.30 mSv for males and 10.00 mSv for females. On low-dose CT scans, the calculated mean effective radiation dose was 1.40 mSv for males and 1.97 mSv for females. CONCLUSION: Compared with standard scans using 260 mAs, low-dose unenhanced helical CT using a reduced tube current of 50 mAs results in a concomitant decrease in the radiation dose of 81%. Although low-dose CT was limited in its ability to depict small-sized calculi less than or equal to 2 mm, it is still comparable to standard-dose CT for the diagnosis of ureter stones and alternative disease. 相似文献
14.
15.
不同管电流对正常颅脑CT灌注参数和辐射剂量的影响 总被引:2,自引:0,他引:2
目的分析管电流与正常颅脑各灌注参数及图像质量之间的关系,探讨低电流颅脑CT灌注扫描的可行性。资料与方法 2010年7月至2011年5月所有拟行颅脑CT灌注检查的受检者,按管电流随机分为A组(常规剂量组)(200 mA),B组(150 mA),C组(120 mA),D组(100 mA)不同管电流进行扫描,每组筛选10例无颅脑疾病者进行研究。在额叶、颞叶及小脑白质对称各选取3个感兴趣区,分别测量脑血流量(CBF)、脑血容量(CBV)、平均通过时间(MTT)和达峰时间(TTP),噪声(SD)及辐射剂量(E),计算对比度噪声比(CNR)、变异系数(CV)及信噪比(SNR),并对各参数进行统计学分析,记录各组辐射剂量。结果各兴趣区各项灌注参数在4组间比较差异无统计学意义。在4组间两两比较结果显示,A组与D组额叶、颞叶、小脑CBF及额叶、颞叶CBV组间两两比较差异有统计学意义,A组与C组颞叶CBF及额叶CBV组间两两比较差异有统计学意义,A组与B组各项灌注参数组间两两比较差异无统计学意义。各组客观图像质量指标在4组间比较差异显著,而在4组间两两比较结果显示A组与B组CNR差异无统计学意义。随着电流的降低,CV、SD有升高趋势,SNR有降低趋势。A~D组的吸收剂量分别为2.39 mSv、1.79 mSv、1.43 mSv、1.2 mSv。结论以150 mA的低管电流行颅脑CT灌注扫描对灌注参数和图像质量无明显影响,与常规剂量组对比辐射剂量降低25%,可用于低剂量颅脑CT灌注扫描。 相似文献
16.
低剂量CT肺动脉成像的实验研究 总被引:2,自引:0,他引:2
目的 通过模型实验证实低剂量CT肺动脉成像(CTPA)的可能性并筛选出合理低剂量阈值.方法 测量132例患者气管内、体外空气密度差,制成噪声测量和肺动脉栓塞(PE)模型.设置管电压为120 kVp,管电流分别为280、200、160、100、90、80、70、60、50、40、30、20、15、10 mA,扫描上述两种模型和水模,采用标准算法和软组织算法重建,3名阅片者独立评判图像质量.应用Pearson线性相关分析、配对t检验、方差分析和Kappa检验进行统计学分析.结果 132例患者气管内、体外空气密度差范围在20.00~55.00 HU,与体质量[(64.99±11.86)kg]、体质量/身高[(38.71±6.13)kg/m]及体质量指数(BMI)[(23.11±3.38)ks/m2]呈正相关(r值分别为0.288、0.374、0.449,P值均<0.01).两种模型标准算法[噪声分别为(22.43±11.25)、(21.99±11.67)HU]与软组织算法[(16.55±9.08)、(16.42±9.40)HU]之间噪声差异有统计学意义(F=4.316,P<0.05),软组织算法噪声水平低于标准算法,而与使用何种体模无关.软组织算法100 mA时图像噪声水平与标准算法280 mA时相当,PE模型图像信噪比(SNR)和对比噪声比(CNR)分别为23.05、20.52,不影响对栓塞的识别;软组织算法60 mA时噪声水平与标准算法160 mA时相当,PE模型图像SNR、CNR分别为18.01、15.97,亦不影响栓子定性观察;30 mA以下图像质量明显下降,PE模型图像SNR、CNR分别在12.36、10.95以下,模拟栓子检出能力下降.3名阅片者图像质量判读结果之间一致性高(Kappa值分别0.807、0.712和0.904,P值均<0.01).结论 100 mA可能是比较理想的低剂量CTPA扫描条件;30 mA可能是诊断所需的最低扫描条件;软组织算法成像能减少SNR损失. 相似文献
17.
泌尿系结石螺旋CT低辐射量扫描的临床应用 总被引:1,自引:0,他引:1
目的:探讨螺旋CT低剂量扫描在泌尿系结石诊断中的临床应用价值。方法:对75例临床怀疑泌尿系结石患者根据就诊顺序分为3组:标准剂量组、低剂量组1和低剂量组2,标准剂量组采用120kV,180mA,螺距0.938进行扫描;低剂量组1和低剂量组2分别采用管电流120mA、80mA进行扫描,其它扫描条件与标准剂量组相同。记录每次扫描的放射容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)和有效剂量(ED)。由两位具有10年以上CT工作经验的医师进行影像诊断和图像质量评估,计算标准剂量和低剂量CT检查诊断泌尿系结石的敏感度、诊断符合率和阳性预测值。对所有图像进行主观质量评分,并测量其客观噪声值。结果:两个低剂量组与标准剂量组比较,CT剂量指数分别减少29.7%和55.5%,低剂量组1、2对泌尿系结石诊断的敏感度均为93.8%,诊断符合率分别为96.0%和95.5%,阳性预测值分别88.2%和100%,与标准剂量组比较差异均无统计学意义。图像质量方面,尽管剂量降低后图像噪声有所增加,但所有图像质量仍符合诊断要求。结论:低剂量螺旋CT扫描能满足泌尿系结石的诊断要求,大大降低了受检者的辐射剂量。 相似文献
18.
目的:探讨多层螺旋 CT 低剂量扫描技术在甲状腺增强扫描中的临床应用价值。方法80例患者随机分为4组(每组各20例),4组分别为:A 组,120 kV、180 mA;B 组,120 kV、100 mA;C 组,100 kV、180 mA;D 组,100 kV、100 mA。主观评价图像质量并评分,统计甲状腺 CT 值、图像背景噪声(N)、图像信噪比(SNR)、CT 剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)并进行对比分析。结果4组图像主观评分为3.90±0.31、3.75±0.44、3.70±0.47、3.60±0.60,SNR 为26.34±3.13、25.08±1.87、25.86±2.38、24.87±2.20,四者无统计学差异(P >0.05);甲状腺 CT 值为(168.55±13.39)HU、(170.70±11.34)HU、(185.20±22.35)HU、(190.55±21.38)HU,N 为(6.48±0.84)HU、(6.83±0.45)HU、(7.19±0.86)HU、(7.66±1.01)HU, CTDIvol 为(10.95±0.00)mGy、(6.08±0.00)mGy、(6.59±0.00)mGy、(3.66±0.00)mGy,DLP 为(145.67±8.79)mGy·cm、(84.58±4.94)mGy·cm、(89.86±3.26)mGy·cm、(50.20±1.89)mGy·cm,ED 为(0.73±0.04)mSv、(0.42±0.03)mSv、(0.45±0.03)mSv、(0.25±0.01)mSv,四者有统计学差异(P <0.05)。结论多层螺旋 CT 低剂量扫描技术既能保证图像质量又能有效降低甲状腺增强 CT 检查的辐射剂量。 相似文献