首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
目的 探讨早期妊娠人工流产术后即刻放置宫内节育器的效果。方法 选取2012年9月~2014年1月非洲喀麦隆吉德大区医院放置宫内节育器的育龄妇女80例,根据置环时间分为观察组和对照组,各40例,其中观察组为人工流产术后即刻放置宫内节育器,对照组为下次月经干净后3~7天放置宫内节育器,并于置环后1月、3月和6月月经干净后3~7天随访,观察两组患者的临床效果。结果 比较两组放置宫内节育器的脱落取出、带宫内节育器妊娠、子宫穿孔、不规则阴道出血、术后感染情况,差异无统计学意义(P0.05)。结论 人工流产术后即刻放置宫内节育器安全、有效,值得临床应用。  相似文献   

2.
无论是自然因素导致的流产(spontaneousabor-tion),还是机械或药物等人为因素终止妊娠的流产(inducedabortion),其流产后避孕的方法选择尤为重要。及时采用正确的避孕措施,将减少非意愿妊娠和不必要的人工流产。目前可供选择的避孕方法包括口服避孕药、避孕针、避孕套、宫内节育器、绝育术、皮  相似文献   

3.
目的探讨人工流产(人流)术后即时放置吉妮致美、活性γ型、TCu宫内节育器(IUD)和左炔诺孕酮宫内缓释系统(LNG-IUS)的安全性和有效性。方法收集2012年3月至2013年9月本院行人流术、并自愿于术后即时放置IUD的女性215例为研究对象,其中术后放置吉妮致美IUD 75例、活性γ型IUD65例、TCu IUD 30例、LNG-IUS 45例,分别于放置后1、3、6个月时随访,观察IUD使用情况、月经变化/阴道出血模式及副反应等,分析人流术后即时放置IUD的临床效果。结果放置后6个月内,4种IUD带器妊娠率、IUD相关脱落率、医疗原因取出率和续用率比较,差异均无统计学意义(P0.05);放置后3个月内,4种IUD的月经模式改变(包括出血时间、点滴出血时间及总出血时间)比较,差异有统计学意义(P0.05),其中吉妮致美和活性γ组出血时间短于TCu组和LNG-IUS组(P0.05);4种IUD月经量改变、经期延长(周期缩短)及疼痛率比较,差异有统计学意义(P0.05),其中LNG-IUS组痛经改善好于其他各组(P0.05)。结论4种IUD在人流术后即时放置安全、可行、有效;吉妮致美和活性γ组IUD月经时间短于TCu组,LNGIUS相对于其他3种IUD可以有效缓解痛经症状,有助于提高妇女对放置IUD的接受性和满意度。  相似文献   

4.
患者 2 7岁 ,孕 1产 1,因不规则阴道出血 2 0天伴下腹疼痛加重 5小时 ,2 0 0 0年 12月 9月入院。患者末次月经不清 ,2 0天前出现阴道不规则出血 ,伴下腹疼痛 ,无明显的早孕反应。在外院抗炎治疗 ,输液 5天无好转 ,5小时前 ,因下腹疼痛加剧来本站就诊。以往月经规律 ,经期周期正常 ,无痛经史 ,2年前安宫内节育器。查体 :体温 36 .6℃ ,脉搏 10 0 / min,呼吸 2 2 / m in,血压 10 /6 k Pa,急性痛苦病容 ,贫血貌 ,神清合作 ,心肺无异常 ,腹平软 ,下腹部压痛 ,左侧为甚 ,无明显反跳痛及肌紧张 ,未扪及包块 ,外阴及阴道血染 ,少许血性分泌物流出 …  相似文献   

5.
人工流产术即时放置吉妮宫内节育器1564例分析   总被引:8,自引:0,他引:8  
目的探讨人工流产术即时放置吉妮宫内节育器(GyneFixIN/SIUD,INIUD)的效果。方法2002年3月至2003年3月四平市妇婴医院对停经5~10周,要求终止妊娠且同时需避孕的妇女1564例,在人工流产术即时放置INIUD,术后定期随访。结果1564例累计观察15个月,妊娠率0.13%,脱落率0.06%,续用率99.36%,因症取出率0.45%。结论人工流产术即时放置INIUD安全性高,避孕效果可靠,具有脱落率低,副反应少等优点,适于临床应用。  相似文献   

6.
目的 了解3种常用宫内节育器(IUD)在人工流产术后即时放置的临床效果和安全性.方法 通过前瞻性随机对照临床研究,对来自全国7个省市的12个协作中心的1800例研究对象于人工流产术后即时放置IUD,放置的IUD类型分为宫形含铜IUD宫铜200、T形含铜IUDTCu380A和活性γ型IUD 3种,每种分别观察600例,并随访12个月.结果 1798例完成了使用12个月的随访,2例失访(失访率为0.11%,2/1800);17例不符合纳入标准的未产妇资料在进行数据统计分析时被剔除.3种IUD使用者均未发生妊娠(或带器妊娠),且均无子宫穿孔、IUD异位等并发症发生.活性γ型IUD的医疗原因终止率为1.02/百妇女年,低于宫铜200、TCu380A(分别为3.60/百妇女年、2.25/百妇女年),3者比较,差异有统计学意义(P=0.015).宫铜200、TCu380A和活性.y型IUD中,与IUD使用相关的终止率分别为7.58/百妇女年、7.30/百妇女年和3.72/百妇女年,3者比较,差异有统计学意义(P=0.008).结论 人工流产术后即时放置宫铜200、TCu380A和活性γ型IUD的避孕效果均良好,均安全可行,尤其是国产活性γ型IUD,值得推广.  相似文献   

7.
Objective To compare the safety and effectiveness of three types intrauterine device(IUD) insertion immediately after vacuum aspiration, and to provide evidence for women fulfilling contraception and reducing repeat abortion. Methods A multi-center randomized controlled clinical trial was performed in 12 medical institutions or family planning service stations located in China. Total 1800 eligible women were inserted G-Cu200, TCu380A or active γ-IUD randomly after vacuum aspiration immediately,and they were followed up for 12 months. Results Except for 2 cases who dropped out ( loss rate is 0.11%,2/1800) and 17 cases who didn't match the including standard, the data of 1781 cases was analyzed. No any uterine perforation or ectopic IUD was found. During followed up 12 months, there was also no any pregnancy or pregnancy with IUD in situ occurred in the three groups. The medical removal rate for bleeding or (and) pain of active γ-IUD was the lowest (1.02/hundred women year) among three groups, and there were significant difference (P =0.015 ). The rate of expulsion rate and discontinuation rate of active γ-IUD was 2.73/hundred women year, which was also the lowest among the three IUD, but there was no significantly statistical difference ( P > 0.05 ). Conclusions The results showed that there are perfect clinical safety and effectiveness for three types of IUD immediately after vacuum aspiration. Active γ-IUD is superior to other two types IUD for its low medical removal rate which may be worthy to use widely immediately after vacuum aspiration.  相似文献   

8.
Objective To compare the safety and effectiveness of three types intrauterine device(IUD) insertion immediately after vacuum aspiration, and to provide evidence for women fulfilling contraception and reducing repeat abortion. Methods A multi-center randomized controlled clinical trial was performed in 12 medical institutions or family planning service stations located in China. Total 1800 eligible women were inserted G-Cu200, TCu380A or active γ-IUD randomly after vacuum aspiration immediately,and they were followed up for 12 months. Results Except for 2 cases who dropped out ( loss rate is 0.11%,2/1800) and 17 cases who didn't match the including standard, the data of 1781 cases was analyzed. No any uterine perforation or ectopic IUD was found. During followed up 12 months, there was also no any pregnancy or pregnancy with IUD in situ occurred in the three groups. The medical removal rate for bleeding or (and) pain of active γ-IUD was the lowest (1.02/hundred women year) among three groups, and there were significant difference (P =0.015 ). The rate of expulsion rate and discontinuation rate of active γ-IUD was 2.73/hundred women year, which was also the lowest among the three IUD, but there was no significantly statistical difference ( P > 0.05 ). Conclusions The results showed that there are perfect clinical safety and effectiveness for three types of IUD immediately after vacuum aspiration. Active γ-IUD is superior to other two types IUD for its low medical removal rate which may be worthy to use widely immediately after vacuum aspiration.  相似文献   

9.
放置宫内节育器后子宫异常出血的治疗   总被引:10,自引:0,他引:10  
王欣  韩丽晖 《生殖与避孕》2004,24(3):173-176
宫内节育器(IUD)是我国育龄妇女使用最广泛的避孕方法,具有高效、安全、方便等优点。但放置IUD后,月经量增多,出血期延长等,是影响继续使用IUD的主要原因,为保护广大妇女生殖健康,国内外开展了多项研究。目前主要治疗方法有,抗纤溶制剂、抗前列腺素制剂、止血药、抗氧化剂、含药IUD以及中药针灸等治疗,以提高IUD的续用率。  相似文献   

10.
放置宫内节育器后出血与病毒感染的关系   总被引:13,自引:0,他引:13  
采用病毒分离培养方法对113例放置宫内节育器(IUD)后出血病例(IUD出血组),放置IUD无副作用的109例(IUD正常组)、未放置IUD正常妇女24例(无IUD正常组)及未放置IUD异常子宫出血11例(无IUD异常出血组)的子宫内膜进行病毒分离。各组标本用兔肾细胞进行病毒分离,病毒阳性率依3次为59.29%、19.27%、16.67%、63.64%。分离出的病毒用多聚酶链反庆(PCR)技术鉴定  相似文献   

11.
放置宫内节育器后出血和疼痛的防治   总被引:33,自引:0,他引:33  
宫内节育器 (IUD)具有安全、长效、可逆、简便、经济和不影响性生活等优点 ,但尚存在一定的副反应 ,最常见的为月经异常 (出血 )和疼痛 ,而出血和疼痛是影响IUD续用率的主要因素。我国自“六五”国家计划生育科技攻关以来 ,对IUD出血、疼痛的副反应及其防治作了大量的研究。特别自“七五”以来新型带药带铜IUD的研制成功 ,大大提高了IUD的续用率。1 出血 (月经异常 )根据世界卫生组织 (WHO) 1987年的技术报告丛书所述 ,未用任何避孕措施妇女的月经出血量 ,正常范围为 31~ 39m1,中国妇女为 4 7~ 5 9m1。目前常将经血量 >80ml作为…  相似文献   

12.
1 病例报告 患者,30岁,G3P2,顺产.因停经42天于2008年1月5日来我院就诊,末次月经2007年11月23日,既往月经周期规律,无异常不适.自诉在乡计划生育服务站置宫内节育器(IUD)1年半(无IUD脱落史),人院后常规体格检查:T 36.5℃,P80/min,R 15/min,BP 120/80 mmng,尿HCC(+).B超检查见孕囊直径约2.3 cm,官腔内见IUD.  相似文献   

13.
放置宫内节育器的技术要求   总被引:3,自引:0,他引:3  
放置宫内节育器的技术要求苏州医学院附属二院(215004)徐惠民宫内节育器(以下简称IUD)是一种安全、简便、有效的避孕工具,一次放置能长期避孕,取出后又能迅速恢复生育功能,是目前我国育龄妇女使用最广的避孕方法,若能严格掌握适应证、禁忌证及熟练操作技...  相似文献   

14.
放置宫内节育器的远期安全性   总被引:21,自引:0,他引:21  
放置宫内节育器 (IUD)是目前妇女采用的最主要节育措施 ,具有简便、经济、可逆、长效等特点 ,目前中国有约 80 0 0万以上的育龄妇女使用 ,我国自上世纪 6 0年代推广使用至今已4 0多年。因此 ,应用IUD的远期安全性引起人们高度关注。1 带器异位妊娠据国内外文献报道 ,近年来异位妊娠有增加的趋势 ,造成发生率上升的原因是盆腔炎发病率的上升和异位妊娠诊断手段的提高。IUD与异位妊娠相关性的研究引起学者们关注。以往的研究认为 ,IUD的作用不是杀死精子、抑制排卵 ,主要是使子宫内膜长期受异物刺激引起一种无菌性炎症反应 ,从而改变宫…  相似文献   

15.
宫内节育器放置时间的研究   总被引:5,自引:0,他引:5  
宫内节育器(IUD)在我国避孕措施中占有重要地位、传统常规放置IUD时间是在月经干净3~7天,仅短短的5天时间。为了探索月经周期中大部分时间放置IUD的可行性,我们观察了在月经期及月经干净7天后至月经周期20天内放置IUD的临床效果和副反应,结果如下。  相似文献   

16.
放置宫内节育器后月经间期出血者的宫内微生物感染   总被引:20,自引:0,他引:20  
放置宫内节育器后月经间期出血者的宫内微生物感染鲁荣绥汪宁赵季文徐萃瑜放置宫内节育器(IUD)后子宫出血,是停用IUD的最主要原因。本研究探讨放置无尾丝惰性IUD(不锈钢金属单环及宫形环)后不规则经间期出血,与宫内解脲支原体(UU)、人型支原体(Mh)...  相似文献   

17.
目前宫内放置节育器与继发盆腔感染的关系已被日益重视,而吸引流产后立即进行宫内放置节育器有几个优点:技术操作简单,病人无痛苦,且可立即发生避孕效果。Goldsmsth 等人用双盲法在智利、圣地亚哥研究表明  相似文献   

18.
宫内放置节育器(以下简称放环),是一种作用于局部,对机体功能干扰较少的有效避孕方法,放置一次可使用多年,具有安全、有效、简便、取器后不影响生育等优点,为目前育龄妇女普遍选用的避孕措施,但放环术后月经失调是其弊端。所谓月经失调,即指放环后月经期、量、色、质等方面的改变,常见如月经量多、经期延长、月经中期出血、月经淋漓不净等。目前单纯西医治疗除了消炎止血,没有更好的办法,采用中西医结合的治疗方法,可取得较好的疗效。  相似文献   

19.
放置宫内节育器后子宫卵巢同时妊娠一例   总被引:2,自引:0,他引:2  
  相似文献   

20.
自1973年1月1日作者给未经选择的妇女于产褥早期放置铜T-200及铜7宫内节育器,至1977年6月30日对观察达12个月以上,平均观察27±11个月的242例进行临床分析。163例使用铜T-200,79例使用铜7,最后两年多用铜T-200。大多数在产后6天放入。年龄多为26~30岁,75%为1胎或2胎之后。产后6~8周、6个月、12个月分别进行复查,以后每隔1年复查一次。无子宫穿孔或其他严重并发症发生。年龄、胎次、产后安放日期不影响其效果、副作用的产生以及持续使用情况。铜T-200与铜-7对妊娠率、脱落率、取出率无明显差异,故合并一同分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号