The aim of the present study was to analyze the in vivo effect of biomimetic calcium phosphate coating of titanium implants on periimplant bone formation and bone-/implant contact. Five types of implants were used: 1) Ti6Al4V implants with a polished surface; 2) Ti6Al4V implants with collagen coating; 3) Ti6Al4V implants with a mineralized collagen layer; 4) Ti6Al4V implants with sequential coating of hydroxyapatite (HA) and collagen; and 5) Ti6Al4V implants with HA coating only. All implants had square cross sections with an oblique diameter of 4.6 mm and were inserted press fit into trephine burr holes of 4.6 mm in the mandibles of ten beagle dogs. The implants of five animals each were evaluated after a healing period of 1 month and 3 months, respectively, during which time sequential fluorochrome labeling of bone formation had been performed. Bone formation was evaluated by morphometric measurement of the newly formed bone around the implants and the percentage of implant bone contact. After 1 month, there was a significantly higher percentage of mean bone/implant contact in the HA-coated implants compared to those with polished surface and those with the collagen-coated surface. After 3 months, these differences were not present anymore. Bone apposition was significantly higher next to implants with sequential HA/collagen coating compared to polished surfaces and mineralized collagen layer. It is concluded that biomimetic coating of titanium implants with HA has shown the clearest trend to increase bone-implant contact in the early ingrowth period. The addition of collagen to an HA coating layer may hold some promise when used as sequential HA/collagen coating with mineralized collagen as the surface layer.  相似文献   

2.
The aim of this study was to assess the osseointegration of copper vapor laser-superfinished titanium alloy (Ti6Al4V) implants with pore sizes of 25, 50, and 200 microm in a rabbit intramedullary model. Control implants were prepared by corundum blasting. Each animal received all four different implants in both femora and humeri. Using static and dynamic histomorphometry, the bone-implant interface and the peri-implant bone tissue were examined 3, 6, and 12 weeks postimplantation. Among the laser-superfinished implants, total bone-implant contact was smallest for the 25-microm pores, and was similar for 50- and 200-microm pore sizes at all time points. However, all laser-superfinished surfaces were inferior to corundum-blasted (CB) control implants in terms of bone-implant contact. Within the 12-week study period, remodeling of woven bone initially formed within pores occurred only in the implants with 200-microm pores. Implants with 25-microm pores showed the highest amount of peri-implant bone volume at all time points, indicating that the amount of peri-implant bone was not correlated with the quality of the bone-implant interface. At 3 and 6 weeks postsurgery, we did not find any differences in mineral apposition rates or bone formation rates between the various implant surfaces. However, the peri-implant bone formation rate at the end of the trial was 70 and 62% higher in implants with 50- and 200-microm pores compared with CB implants, respectively. We conclude that, although laser-superfinished implants were not superior to CB control implants in terms of osseointegration, our study has provided further insights into the mechanisms of bone remodeling within pores of various sizes, and may form a basis for future experiments to design optimal implant surfaces with the help of modern laser technology.  相似文献   

3.
Ong JL  Carnes DL  Bessho K 《Biomaterials》2004,25(19):4601-4606
In this study, bone interfacial strength and bone contact length at the plasma-sprayed hydroxyapatite (HA) and titanium plasma-sprayed (TPS) implants were evaluated in vivo. Non-coated titanium (Ti) implants were used as controls. Cylindrical coated or non-coated implants (4.0mm diameter by 8mm long) were implanted in the dogs' mandibles. Loading of the implants was performed at 12 weeks after implantation. At 12 weeks after implantation (prior to loading) and 1 year after loading, implants were evaluated for interfacial bone-implant strength and bone-implant contact length. No significant differences in interfacial bone-implant strength for all groups at 12 weeks after implantation and after 1 year loading in normal bone were found. However, bone contact length for HA implants was significantly higher than the TPS and Ti implants for both periods tested (12 weeks after implantation and 1 year after loading). It was concluded that TPS implants exhibited similar pull-out strength compared to the HA implants. In addition, the lower bone contact length on the TPS surface compared to HA surfaces did not affect the interfacial bone-implant strength for both implants.  相似文献   

4.
The role of nanofeatured titanium surfaces in a number of aspects of in vivo bone-implant integration, and, in particular, their potential advantages over microfeatured titanium surfaces, as well as their specific contribution to osteoconductivity, is largely unknown. This study reports the creation of a unique nanobimorphic titanium surface comprised of nanotrabecular and nanotuft-like structures and determines how the addition of this nanofeature to a microroughened surface affects bone-implant integration. Machined surfaces without microroughness, sandblasted microroughened surfaces, and micro-nano hybrid surfaces created by sandblasting and alkali and heat treatment of Ti-15Mo-5Zr-3Al alloy were subjected to biomechanical, interfacial and histological analyses in a rat model. The presence of microroughness enabled accelerated establishment of biomechanical implant fixation in the early stages of healing compared to the non-microroughened surfaces; however, it did not increase the implant fixation at the late stages of healing. The addition of nanobimorphic features to the microroughened surfaces further increased the implant fixation by as much as 60-100% over the healing time. Bone area within 50 μm of the implant surface, but not beyond this distance, was significantly increased by the presence of nanobimorphic features. Although the percentage of bone-implant contact was also significantly increased by the addition of nanobimorphic features, the greatest improvement was found in the soft tissue intervention between the bone and the implant, which was reduced from >30% to <5%. Mineralized tissue densely deposited with calcium-binding globular proteins was observed in an extensive area of nanobimorphic surfaces after biomechanical testing. This study clearly demonstrates the nanofeature-enhanced osteoconductivity of titanium by an alkali- and heat-treated nanobimorphic surface compared to that by microfeatured surfaces, which results not only in an acceleration but also an improvement of bone-implant integration. The identified biological parameters that successfully detect the advantages of nanofeatures over microfeatures will be useful in evaluating new implant surfaces in future studies.  相似文献   

5.
Hydroxyapatite (HA) was coated onto titanium implants using radio frequency magnetron sputtering. The HA films were crystallized in an autoclave tube using low temperature hydrothermal treatment. The average film thickness on the implant was 1.1 microm. HA-coated and pure-titanium implants were inserted into canine mandibles for up to 24 weeks. Forty-eight implants were placed in eight beagles. After 2, 4, 12 and 24 weeks, implants were retrieved and prepared for histological observation, and the HA film thickness was determined using energy-dispersive X-ray spectroscopy. Light microscopy revealed that, after two weeks, the bone response to the HA-coated implants was much better than to the pure titanium implants, and osteoblasts were observed at the bone-implant interface. After four weeks, the screw threads of the HA-coated implants were almost completely covered with bone. The HA film thickness rapidly decreased up to four weeks of implantation, then gently decreased, reaching 0.40+/-0.03 microm at the upper region of the implant after 12 weeks. That indicates that about 80% of the HA film had dissolved after 12 weeks of implantation. The rate of decrease in the HA film thickness was greater with increasing implant depth.  相似文献   

6.
The purpose of the present study was to evaluate the interface shear strength of unloaded titanium implants with a sandblasted and acid-etched (SLA) surface in the maxilla of miniature pigs. The two best documented surfaces in implant dentistry, the machined and the titanium plasma-sprayed (TPS) surfaces served as controls. After 4, 8, and 12 weeks of healing, removal torque testing was performed to evaluate the interface shear strength of each implant type. The results revealed statistically significant differences between the machined and the two rough titanium surfaces (p <.00001). The machined surface demonstrated mean removal torque values (RTV) between 0.13 and 0.26 Nm, whereas the RTV of the two rough surfaces ranged between 1.14 and 1.56 Nm. At 4 weeks of healing, the SLA implants yielded a higher mean RTV than the TPS implants (1.39 vs. 1. 14 Nm) without reaching statistical significance. At 8 and 12 weeks of healing, the two rough surfaces showed similar mean RTVs. The implant position also had a significant influence on removal torques for each implant type primarily owing to differences in density in the periimplant bone structure. It can be concluded that the interface shear strength of titanium implants is significantly influenced by their surface characteristics, since the machined titanium surface demonstrated significantly lower RTV in the maxilla of miniature pigs compared with the TPS and SLA surfaces.  相似文献   

7.
This article describes the histological and ultrastructural appearance of the interface created in the implantation bed, between bone tissue and implants made of dense sintered hydroxyapatite (HA). Biopsies from dog subjects included: a) loaded permucosal dental implants for tooth substitution, b) subperiosteally placed implants for alveolar bone correction, c) endosseously placed dental root implants to retain ridge form following extraction. The light and electron microscopical results show extensive bone apposition on the osseous sides of the implant surfaces. There is an intimate, direct bone contact without any visible interruption. The bone is of normal lamellar type and continuously connected with the trabecular bone. Bone has grown into the finest surface irregularities of the implant. Collagen fibers of the calcified bone matrix are observed within a distance less than 500 A from the implant surface. The thin (20-100 A) electron dense layer at the bone-implant interface resembled the lamina limitans of organic bone matrix, also seen at the inner walls of the osteocytes lacunes. Deposition of bone gives rise to a biologically stable bone-implant interface, without disturbance of the physiological bone turnover. This is seen as very favorable for desired long term fixation of implant to bone.  相似文献   

8.
A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA-coated or noncoated Ti cylinders were implanted into both tibiae of 32 rabbits (New Zealand Whites). Before implantation the left tibia was contaminated with different quantities of Staphylococcus aureus (10(2)-10(5) CFU). Four weeks after surgery the tibiae were explanted and prepared for microbiological and histomorphometrical examination. Histomorphometrical data, as a representation of implant fixation, were obtained by measuring the percentage of bone around the implants (within a radius of 1 mm from the outer diameter of the implants) and the percentage of the circumference of the implant that was in direct contact with bone. Histomorphometry revealed, in particular for the HA implants, a relationship between the inoculum concentration and/or the presence or absence of infection with the bone contact at the distal implant side. This confirms a relationship between peri-implant infection and bone contact or remodeling. HA-coated implants developed, in the presence of bacteria, more easily a more severe infection than noncoated Ti implants, and we show in the present study that local infection will influence histomorphometrical parameters (bone-implant contact) that determine implant fixation. Precautions to prevent contamination (asepsis) and/or infection (perioperative antibiotics) are even more important for the highly biocompatible HA-coated implant.  相似文献   

9.
The cleanliness of titanium dental implants surfaces is considered to be an important requirement for achieving osseointegration, and it has been hypothesized that the presence of inorganic contaminants could lead to lack of clinical success. Aluminum ions are suspected to impair bone formation by a possible competitive action to calcium. The objective of the present study was to describe the effects of residual aluminum oxide particles on the implant surface on the integration of titanium dental implants as compared to decontaminated implants in a rabbit experimental model. Threaded screw-shaped machined grade 3 c.p. titanium dental implants, produced with high-precision equipment, were used in this study. The implants were sandblasted with 100-120 microm Al2O3 particles at a 5atm pressure for 1min, then 24 implants (control implants) underwent ASTM F 86-68 decontamination process in an ultrasonic bath. The other 24 implants (test implants) were washed in saline solution for 15min. Both test and control implants were air-dried and sterilized at 120 degrees C for 30min. After sterilization the implants were inserted into the tibiae (two test and two control implants in each rabbit). Twelve New Zealand white mature male rabbits were used in this study. The protocol of the study was approved by the Ethical Committee of our University. No complications or deaths occurred in the postoperative period. All animals were euthanized, with an overdose of intravenous pentobarbital, after 4 weeks. A total of 48 implants were retrieved. The images were analyzed for quantitation of percentage of surface covered by inorganic particles, bone-implant contact, multinucleated cells or osteoclasts in contact with the implant surface and multinucleated cells or osteoclasts found 3mm from the implant surface. The differences in the percentages between the two groups have been evaluated with the analysis of variance. The implant surface covered by inorganic particles on test implants was significantly higher than that of control implants (p=0.0000). No statistically significant differences were found in the bone-implant contact percentages of test and control implants (p=0.377). No statistically significant differences were found in the number of multinucleated cells and osteoclasts in contact with the implant surface (p=0.304), and at a distance of 3mm from the implant surface (p=0.362). In conclusion, our histological results do not provide evidence to support the hypothesis that residual aluminum oxide particles on the implant surface could affect the osseointegration of titanium dental implants.  相似文献   

10.
Achieving a stable bone-implant interface is an important factor in the long-term outcome of joint arthroplasty. In this study, we employed an ovine bicortical model to compare the bone-healing response to five different surfaces on titanium alloy implants: grit blasted (GB), grit blasted plus hydroxyapatite (50 microm thick) coating (GBHA), Porocoat(R) (PC), Porocoat(R) with HA (PCHA) and smooth (S). Push-out testing, histology, and backscatter scanning electron microscope (SEM) imaging were employed to assess the healing response at 4, 8, and 12 weeks. Push-out testing revealed PC and PCHA surfaces resulted in significantly greater mechanical fixation over all other implant types at all time points (p <.05). HA coating on the grit-blasted surface significantly improved fixation at 8 and 12 weeks (p <.05). The addition of HA onto the porous coating did not significantly improve fixation in this model. Quantification of ingrowth/ongrowth from SEM images revealed that HA coating of the grit-blasted surfaces resulted in significantly more ongrowth at 4 weeks (p <.05).  相似文献   

11.
This work presents histological analysis of interfaces between bone and heteroplastic implants in dog tibias. The study was performed in four tibias (of four mongrel dogs) into which cylindrical implants were inserted. One ceramic (titania) implant and three grit-blasted titanium implants (with sandblasted and acid-corroded surfaces) were chosen for histological analysis of the implant surface/bone tissue interface. The implants remained in the tibias for eight months and none were loaded during this period. The animals were subsequently sacrificed and the samples were processed for analysis. Light microscope analysis revealed a large amount of osteoid tissue and proximity of osteoblasts and osteocytes to the implant surfaces. In addition, little or no fibrous tissue was observed between the bone and implant surfaces. The titanium implants presented better osseointegration than did the ceramic implant.  相似文献   

12.
The aim of this study was to evaluate quantitatively the behaviour of in vivo hydroxyapatite coated implants (HA) in the rabbit over time, and to compare the results with observations made on titanium plasma spray implants (TPS). Results were analysed according to the percentage of bone contact. Eighteen HA cylindrical implants (3.25 x 8 mm) and 6 TPS cylindrical implants from Steri-Oss were placed in the epiphysis of the femur in 24 white rabbits. Each rabbit received one implant. Three rabbits with one HA implant (n = 3) and 1 rabbit with one TPS implant (n = 1) were sacrificed after implantation periods of 2, 4, 6, 8, 10 and 12 months. Implants were cut along the long axis and prepared for histological and histomorphometrical evaluations. Measurements of coating thickness and percentage of bone contact were performed with scanning electron microscopy analysis on the sides of the implant, in 3 different types of bone, namely cortical, trabecular and marrow. In cortical bone, dense bone was apposed to the HA implants: from 92.3 +/- 5.5% at 2 months to 89.6 +/- 6.5% at 1 year, with no significant regression of HA thickness (P = 0.37). TPS coating showed less bone contact, but thickness was stable (P = 0.46). In trabecular zone, where bone contact was less pronounced, a significant regression of HA coatings thickness (P < 0.05) was observed. Nevertheless TPS coatings were stable (P = 0.81). Histomorphometrical results demonstrated that a highly significant regression (P < 0.0001) of HA thickness was observed in the marrow area, where the bone-to-implant contact never exceeded 7.6% from 2 to 12 months. TPS coating did not reveal any sign of resorption (P = 0.88), despite a rare bone contact. Histological analysis revealed inflammatory and giant cells, principally in the marrow area in contact with HA coating, but always in restrictive numbers. We conclude that bone contact protected the HA coating from resorption.  相似文献   

13.
Thin and defect-free calcium phosphate films with a Ca/P ratio of 1.62 were formed by electron-beam evaporation. The as-deposited films had average bonding strengths to the metal implants of 64.8 MPa and the dissolution rates of 47.5 nm/h in isotonic saline solutions. The interface mechanical characteristics and histology of the as-machined, as-blasted, and calcium phosphate coating on the machined surfaces of commercially pure titanium were investigated. After a healing period of 12 weeks, the implants were unscrewed with a torque gauge instrument at the day of sacrifice. The coated sample showed a removal torque of 48.5 Ncm (SD 5.4) compared to 32.3 Ncm (SD 2.91) for the uncoated implant with the same surface roughness, and 47.3 Ncm (SD 5.8) for the grit blasted screw. The histomorphometric analyses of the calcium-phosphate-coated implants revealed a mean of 52.4% (SD 6.3) as the highest bone to implant contact.  相似文献   

14.
The SLA (sandblasted with large grit and acid etched) surface is a textured surface that has been documented to lead to a rapid and strong implant fixation. The purpose of the present study was to determine the contribution of sandblasting in addition to etching to implant anchorage. It was also aimed to determine if the pits carved during etching alone have a bone-interlocking capacity that leads to microanchorage between the implant and bone. SLA implants and machined-and-acid-etched (MA) implants were placed in the maxilla of Land Race pigs. After 10 weeks of healing, they were reverse torqued. The reverse torque of the SLA and MA implants was 157.29 +/- 38.04 N cm and 105.33 +/- 25.12 N cm, respectively. Sandblasting increased bone anchorage by 49.3%; the difference was statistically significant (p =.028). Bone was found attached to both surfaces; bone ingrowth was found in the pits of both surfaces. It is suggested that the two surfaces are able to generate bone interlocking and mechanical coupling at the interface. When finite-element modeling is performed with these surfaces, it is suggested that the bound mode be used instead of the slip mode.  相似文献   

15.
Roentgen Stereophotogrammetric Analysis (RSA) studies have shown that the quality of the early fixation of implants has a dominant effect on their long-term function. To evaluate methods to improve their fixation, we examined the influence of mechanical loading and surface coating on the quality of the bone-implant interface. We compared the fixation of a cylindrical, stable 6.0 mm implant initially surrounded by a 0.75 mm concentric gap, after 4 weeks of loaded or unloaded conditions. Two types of surfaces were analyzed: plasma sprayed hydroxyapatite (HA) and plasma sprayed titanium (Ti). The histomorphometric evaluation showed that HA implants had greater bone coverage than Ti implants, and this coverage was further increased under loaded conditions only for HA. Furthermore, loading reduced the fibrous tissue coverage for the HA implants, while it increased fibrous tissue coverage for Ti implants. These findings were in agreement with pushout results showing that HA implants had greater shear strength, stiffness, and energy than Ti implants, and (except for energy) these parameters were further increased under loaded conditions only for HA. In addition, because the two implant surfaces exhibited a different relative response to load, it is important to evaluate new surfaces under the more clinically relevant loaded condition.  相似文献   

16.
阳极氧化伴水热处理制备纯钛羟基磷灰石薄涂层   总被引:4,自引:0,他引:4  
为了解纯钛阳极氧化伴水热处理的技术路线及羟基磷灰石薄涂层在体内的成骨效应,以钛片为阳极,β-磷酸甘油钠和醋酸钙为电解质,经200-400V直流电解15min,维持电流密度≤50mA/cm^2,而后经280℃-300℃水热处理2h,取光滑,喷砂表面作对照,分别植入12只兔股骨内,枯术后4,8,16周取出带种植体骨块制作磨片,观察新骨生成情况及术后8周光滑和涂层种植体的界面超微结构,并作表面能谱分析,结果发现水热处理后,钛片表面出现了羟基磷灰石涂层,动物实验显示涂层种植体8周后编织骨的转化和成熟较快,未见剥脱的羟基磷灰石碎片,其表面的钙,磷含量在种植后增加明显,这说明阳极氧化伴水热处理可以制备出纯钛表面羟基磷灰石薄涂层,其早期促编织骨形成作用明显,可以加快编织骨转化成板层骨。  相似文献   

17.
The objective of this study was to evaluate the effect of radio frequency sputtered calcium phosphate (CaP) coatings of titanium (Ti) implants on the bond strength at the bone-implant interface and percent bone contact length. Cylindrical coated or noncoated implants (4.0-mm diameter by 8-mm long) were implanted for 3 and 12 weeks. At 3 weeks after implant placement, the ultimate interfacial strengths for as-deposited CaP-coated and heat-treated CaP-coated implants were 2.29 +/- 0.14 MPa and 1.28 +/- 0.04 MPa, respectively. These ultimate interfacial strength values at 3 weeks were statistically greater than the mean ultimate interfacial strength for control Ti implants (0.67 +/- 0.13 MPa). At 12 weeks after implant placement, no statistical differences in the mean ultimate interfacial strengths were observed between the as-deposited CaP-coated, heat-treated CaP-coated, and control Ti implants. Histomorphometric evaluation indicated greater percent bone contact lengths for the as-deposited CaP-coated implants compared with the heat-treated CaP-coated and control Ti implants 3 and 12 weeks after implant placement.  相似文献   

18.
Ueno T  Tsukimura N  Yamada M  Ogawa T 《Biomaterials》2011,32(30):7297-7308
This study introduces nanopolymorphic features of alkali- and heat-treated titanium surfaces, comprising of tuft-like, plate-like, and nodular structures that are smaller than 100 nm and determines whether and how the addition of these nanofeatures to a microroughened titanium surface affects bone-implant integration. A comprehensive assessment of biomechanical, interfacial, and histological analyses in a rat model was performed for machined surfaces without microroughness, sandblasted-microroughened surfaces, and micro-nano hybrid surfaces created by sandblasting and alkali and heat treatment. The microroughened surface accelerated the establishment of implant biomechanical fixation at the early healing stage compared with the non-microroughened surface but did not increase the implant fixation at the late healing stage. The addition of the nanopolymorphic features to the microroughened surface further increased implant fixation throughout the healing time. The area of the new bone within 50 μm proximity of the implant surfaces, which was increased 2-3-fold using microroughened surfaces, was further increased 2-fold using nanopolymorphic surfaces. In contrast, the bone area in a 50-200 μm zone was not influenced by either microroughened or nanopolymorphic surfaces. The percentage of bone-implant contact, which was increased 4-5-fold, using microroughened surfaces, was further increased substantially by over 2-fold throughout the healing period. The percentage of soft tissue intervention between bone and implant surfaces, which was reduced to half by microroughened surfaces, was additionally reduced by the nanopolymorphic surfaces to between one-third and one-fourth, resulting in only 5-7% soft tissue intervention compared with 60-75% for the non-microroughened surface. Thus, using an exemplary alkali- and heat-treated nanopolymorphic surface, this study identified critical parameters necessary to describe the process and consequences of bone-implant integration, for which nanofeatures have specific and substantial roles beyond those of microfeatures. Nanofeature-enhanced osteoconductivity, which resulted in both the acceleration and elevation of bone-implant integration, has clearly been demonstrated.  相似文献   

19.
The influence of calcium phosphate (Ca-P) coating and surface roughness on the trabecular bone response of titanium implants was investigated. Four types of titanium implants, i.e. blasted with titanium powder, sintered with titanium beads, titanium powder blasted and provided with an additional Ca-P coating, and titanium beads with Ca-P coating, were prepared. The Ca-P coating was deposited by ion beam dynamic mixing method. The Ca-P coating was rapid heat-treated with infrared radiation at 700 degrees C. The implants were inserted into the trabecular bone of the left and right femoral condyles of 16 rabbits. After implantation periods of 2, 3, 4 and 12 weeks, the bone-implant interface was evaluated histologically and histomorphometrically. Histological evaluation revealed new bone formation around different implant materials after already 3 weeks of implantation. After 12 weeks, mature trabecular bone surrounded all implants. At 3 and 4 weeks of implantation, no difference existed in bone contact to the various implant materials. On the other hand, after 12 weeks of implantation the highest percentage of bone contact was found around the Ca-P coated beads implants. Supported by the results, we concluded that the combination of surface geometry and Ca-P coating benefits the implant-bone response during the healing phase.  相似文献   

20.
In the study, characterization of the anodized titanium surface was performed. In addition, histological evaluation and interfacial strength at the bone-implant interface of the characterized surfaces were then evaluated with the use of a rabbit model at 6 and 12 weeks after implantation. Surface treatments consisted of either anodization or anodization followed by hydrothermal treatments. Nontreated titanium surfaces were used as controls in this study. Using scanning-electron microscopy, porous oxide layers were observed on surfaces of anodized titanium implants, whereas porous oxide layers and HA needles were observed on anodized titanium implants following hydrothermal treatments. X-ray diffraction analysis showed the oxide layers were consisted mainly of anatase and a little of rutile. By the hydrothermal treatment on the anodizing surface, HA peaks, as well as the peaks of anatase and trace amounts of rutile peaks were observed. In EPMA analysis, the Ca/P ratio for the anodic oxide was 1.54 for anodized surfaces, whereas the Ca/P ratios for HA needles and the anodic oxide were 1.64 and 0.57, respectively, for anodized surfaces following hydrothermal treatments. Although no significant difference was observed for the percent bone contact on all implants evaluated in the in vivo study, the removal torque strength was significantly higher for anodized implants (48.02+/-5.92 N/cm) than the untreated implants (controls) (27.83+/-1.78 N/cm) at 6 weeks after implantation. As such, it was concluded that the surface anodized implants resulted in a high interfacial strength at an early implantation period as compared to the nontreated titanium implants.  相似文献   