首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到3条相似文献,搜索用时 0 毫秒
1.
Magnetic resonance (MR) phase-velocity mapping (PVM) is routinely being used clinically to measure blood flow velocity. Conventional nonsegmented PVM is accurate but relatively slow (3–5 min per measurement). Ultrafast k-space segmented PVM offers much shorter acquisitions (on the order of seconds instead of minutes). The aim of this study was to evaluate the accuracy of segmented PVM in quantifying flow from through-plane velocity measurements. Experiments were performed using four straight tubes (inner diameter of 5.6–26.2 mm), under a variety of steady (1.7–200 ml/s) and pulsatile (6–90 ml/cycle) flow conditions. Two different segmented PVM schemes were tested, one with five k-space lines per segment and one with nine lines per segment. Results showed that both segmented sequences provided very accurate flow quantification (errors<5%) under both steady and pulsatile flow conditions, even under turbulent flow conditions. This agreement was confirmed via regression analysis. Further statistical analysis comparing the flow data from the segmented PVM techniques with (i) the data from the nonsegmented technique and (ii) the true flow values showed no significant difference (all p values0.05). Preliminary flow measurements in the ascending aorta of two human subjects using the nonsegmented sequence and the segmented sequence with nine lines per segment showed very close agreement. The results of this study suggest that ultrafast PVM has great potential to measure blood velocity and quantify blood flow clinically. © 2002 Biomedical Engineering Society. PAC2002: 8761Lh, 8757Nk, 8719Uv  相似文献   

2.
A combined computational fluid dynamics (CFD) and magnetic resonance imaging (MRI) methodology has been developed to simulate blood flow in a subject-specific left heart. The research continues from earlier experience in modeling the human left ventricle using time-varying anatomical MR scans. Breathing artifacts are reduced by means of a MR navigator echo sequence with feedback to the subject, allowing a near constant breath-hold diaphragm position. An improved interactive segmentation technique for the long- and short-axis anatomical slices is used. The computational domain is extended to include the proximal left atrium and ascending aorta as well as the left ventricle, and the mitral and aortic valve orifices are approximately represented. The CFD results show remarkable correspondence with the MR velocity data acquired for comparison purposes, as well as with previously published in vivo experiments (velocity and pressure). Coherent vortex formation is observed below the mitral valve, with a larger anterior vortex dominating the late-diastolic phases. Some quantitative discrepancies exist between the CFD and MRI flow velocities, owing to the limitations of the MR dataset in the valve region, heart rate differences in the anatomical and velocity acquisitions, and to certain phenomena that were not simulated. The CFD results compare well with measured ranges in literature.© 2003 Biomedical Engineering Society.  相似文献   

3.
Block regional interpolation scheme for k space (BRISK) is a sparse sampling approach to allow rapid magnetic resonance imaging of dynamic events. Rapid velocity encoded cine (VEC) imaging with Turbo BRISK is potentially an important clinical diagnostic technique for cardiovascular diseases. Previously we applied BRISK and Turbo BRISK to imaging pulsatile flow in a straight tube. To evaluate the capabilities of Turbo BRISK imaging in more complex dynamic flow fields such as might exist in the human vasculature, an in vitro curved tube model, similar in geometry to the aortic arch, was fabricated and imaged under pulsatile flow conditions. Velocity maps were obtained using conventional VEC and Turbo BRISK (turbo factors 1 through 5). Comparison of the flow fields obtained with each higher order turbo factor showed excellent agreement with conventional VEC with minimal loss of information. Similarly, flow maps showed good agreement with the profiles from a laser Doppler velocimetry model. Turbo-5 BRISK, for example, allowed a 94% savings in imaging time, reducing the conventional imaging time from over 8 min to a near breath-hold imaging period of 31 s. Turbo BRISK shows excellent promise toward the development of a clinical tool to evaluate complex dynamic intravascular flow fields. © 2001 Biomedical Engineering Society. PAC01: 8761Lh, 8719Uv  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号