首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Functionalized poly N,N-dimethylaniline film was prepared by adsorption of ferrocyanide onto the polymer forming at the surface of carbon paste electrode (CPE) in aqueous solution. The electrocatalytic ability of poly N,N-dimethylaniline/ferrocyanide film modified carbon paste electrode (PDMA/FMCPE) was demonstrated by oxidation of l-cysteine. Cyclic voltammetry and chronoamperometry techniques were used to investigate this ability. In the optimum pH (6.00), the electrocatalytic ability about 480 mV and the catalytic reaction rate constant, (kh), can be seen 3.08 × 103 M−1 s−1. The catalytic oxidation peak current determined by cyclic voltammetry method was linearly dependent on the l-cysteine concentration and the linearity range obtained was 8.00 × 10−5 –2.25 × 10−3 M. Detection limit of this method was determined as 6.17 × 10−5 M (2σ). At a fixed potential under hydrodynamic conditions (stirred solution), the calibration plot was linear over the l-cysteine concentration range 7.40 × 10−6 M–1.38 × 10−4 M. The detection limit of the method was 6.38 × 10−6 M (2σ).  相似文献   

2.
In this paper, a multiwall carbon nanotube/Nafion composite modified glassy carbon electrode (MWNT/Nafion/GCE) was used as a voltammetric sensor to determine 8-hydroxyquinoline (8-HQ) in cosmetic. This voltammetric sensor exhibited strong catalytic effect toward the oxidation of 8-HQ and caused an anodic peak at 0.97 V in HAc-NaAc buffer solution (0.2 M, pH 3.6). Under the optimized condition, the anodic peak current was linear with the concentration of 8-HQ in the range of 2 × 10−8 M–1.0 × 10−5 M. The detection limit was 9 × 10−9 M. The practical application of MWNT/Nafion/GCE was carried out for determining 8-HQ in cosmetic sample with satisfactory results. The electrode reaction mechanism was studied by cyclic voltammetry and UV–vis spectra.  相似文献   

3.
Cyclic voltammetric investigation of calcium dobesilate (CD) in aqueous acid media was carried out by using an ordered mesoporous carbon-modified pyrolytic graphite electrode (OMC/PGE). A pair of well-defined redox peaks of CD was observed at the OMC/PGE, showing its good elelctrochemial response towards CD. The anodic current is linear with CD concentration in the range of 1.0 × 10−7–1.3 × 10−3 mol L−1, with a detection limit of 4.0 × 10−8 mol L−1. Meanwhile, the proposed electrode can avoid some interference coexisting with CD, such as uric acid, serotonin, and ascorbic acid. The proposed method can be potentially applied for selective electrochemical sensing of CD in physiological condition.  相似文献   

4.
The functionalized carbon nanotube electrode was fabricated by electrodeposition of 1,2-naphthoquinone-4-sulfonic acid sodium (Nq) on single-wall carbon nanotube (SWNT) modified glassy carbon electrode (GCE). This electrode was characterized by scanning electron microscopy (SEM) and the results showed that Nq can rapidly and effectively be deposited on the surface of SWNT film with high stability. The electrochemical properties of functionalized SWNT/GCE with Nq (SWNT–Nq/GCE) were studied using cyclic voltammetry, double step potential chronoamperometry and differential pulse voltammetry methods. The results indicated that SWNT could improve the electrochemical behavior of Nq and greatly enhances its redox peak currents. The SWNT–Nq/GCE exhibited a pair of well-defined redox peaks. The experimental results also demonstrated that the Nq deposited species on SWNT could catalyze cysteamine oxidation and SWNT–Nq exhibited a high performance with lowering the overpotential by more than 710 mV. The effect of pH value, number of scans and Nq concentration were investigated on the electrochemical behavior of cysteamine. The selectivity of the reaction has been assessed with no interference from tyrosine, lysine, methionine, tryptophan, alanine and glutathione. The presented method has highly selectivity for voltammetric detection of cysteamine in the dynamic range from 5.0 × 10−6 M to 2.7 × 10−4 M and with a detection of limit (3σ) 3.0 × 10−6 M.  相似文献   

5.
A novel electrochemical sol–gel imprinted sensor for sensitive and convenient determination of thymidine was developed. Thin film of molecularly imprinted sol–gel polymers with specific binding sites for thymidine was cast on carbon electrode by electrochemical deposition. Multi-walled carbon nanotubes (MWCNTs) were introduced for the enhancement of electronic transmission and sensitivity. The morphology and performance of the imprinted film was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV) and amperometric measurements (it) in detail. The results showed that the imprinted film exhibited high selectivity toward thymidine. The linear range is over the range from 2 to 22 μmol L−1, and the linear regression equation for thymidine is I = 0.867C + 0.232 with the detection limit of 1.6 × 10−9 mol L−1(S/N = 3). The imprinted sensor was successfully employed to detect thymidine in some zidovudine-tablet samples.  相似文献   

6.
Molecularly Imprinted poly[tetra(o-aminophenyl)porphyrin] is presented as an electrosynthesized coating for the development of selective microsensors. A carbon fiber microelectrode has been modified with this covering by cyclic voltammetry in the potential range from −0.15 to 1.0 V (scan rate 50 mV s−1) obtaining a microsensor able to recognize the template molecule. To carry out this study dopamine was chosen as model to work with, since this molecule presents electroactivity as it can be oxidized on carbon electrodes. The MIP sensor presented a linear response to the dopamine concentration in the range from 10−6 to 10−4 M with good repeatability (RSD 6.22%). The selectivity shown by the microsensor was found to be excellent as it was able to differentiate between different catecholamines. A method has been developed for the determination of dopamine in brain tissue samples using the MIP microsensor.  相似文献   

7.
This research in finding a cheap and efficient catalyst for electrooxidation of formaldehyde give us an attempt to make and examine the behavior of poly(N-methylaniline)/nickel modified carbon paste electrode (Ni/P(NMA)/MCPE) in absence and presence of formaldehyde. This involves in situ electropolymerization of N-methylaniline at carbon paste electrode, which is following to the incorporation of Ni(II) to polymeric layer by immersion of modified electrode in 1.0 M nickel sulphate solution. The electrocatalytic oxidation of formaldehyde was studied by cyclic voltammetry and chronoamperometry methods. The effects of scan rate and formaldehyde concentration on the electrocatalytic oxidation of formaldehyde were also investigated at the surface of Ni/P(NMA)/MCPE. The diffusion coefficient (D = 14.1 × 10−5 cm2 s−1), and some kinetic parameters such as the transfer coefficient (α = 0.45) and also second-order rate constant (k = 8.96 × 10−4 cm3 mol−1 s−1) of formaldehyde were calculated.  相似文献   

8.
A novel modified carbon-paste electrode was employed for the simultaneous determination of dopamine (DA) and ascorbic acid (AA) with good selectivity and high sensitivity. Silver nanoparticle and carbon nanotube modified carbon-paste electrode (Ag/CNT–CPE) displayed excellent electrochemical catalytic activities towards dopamine (DA) and ascorbic acid (AA). The oxidation overpotentials of DA and AA were decreased significantly compared with those obtained at the bare CPE. Differential pulse voltammetry was used for the simultaneous determination of DA and AA. The peak separation between DA and AA was 67 mV. The calibration curves for DA and AA were obtained in the range of 8.0 × 10−7–6.4 × 10−5 M and 3.0 × 10−5–2.0 × 10−3 M, respectively. The lowest detection limits (S/N = 3) were 3.0 × 10−7 M and 1.2 × 10−5 M for DA and AA, respectively. Method was applied to the determination of DA and AA in real samples.  相似文献   

9.
Here we report the selective, sensitive and simultaneous determination of dopamine (DA), ascorbic acid (AA) and uric acid (UA) on ordered mesoporous carbon (OMC)/Nafion composite film. Insoluble OMC was dispersed into ethanol in the presence of 0.5% Nafion, resulting in a stable and well-distributed OMC/Nafion suspension. After evaporation of ethanol, a uniform OMC/Nafion composite film-coated glassy carbon electrode (GCE) was achieved by simple casting deposition. The OMC/Nafion electrode shows ideal reversibility in 5 mM K3[Fe(CN)6] in the range of 0.02–0.50 V s−1, indicating a fast electron-transfer kinetics. Moreover, due to the strong catalytic function of OMC, the overlapping voltammetric response of DA, AA and UA is well-resolved from each other with lowered oxidation potential and enhanced oxidation currents. The mechanism for the oxidation of AA, DA and UA at the OMC/Nafion film was also studied. By using differential pulse voltammetry (DPV), detection limits of 0.5, 20 and 4.0 μM were obtained for DA, AA and UA, respectively. The practical application of the electrode is successfully demonstrated for the determination of DA, AA and UA simultaneously in standard and real samples, without any preliminary treatment.  相似文献   

10.
Potentiometric electrodes based on the incorporation of surfactant-modified zeolite Y (SMZ) particles into poly vinyl chloride (PVC) membranes were described. The electrode characteristics were evaluated regarding the response towards perchlorate ions. PVC membranes plasticized with dioctyl phthalate and without lipophilic additives (co-exchanger) are used throughout this study. The influence of membrane composition on the electrode response was studied. The electrode exhibited a Nernstian response towards perchlorate in the concentration range of 7.9 × 10−6–8.0 × 10−2 M with a slope of 59.7 ± 0.9 mV per decade of perchlorate concentration with a working pH range of 1.7–9.5 with a fast response time of ≤10 s. The lower and upper detection limits were 4.07 × 10−7 and 0.13 M, respectively. The electrode response to perchlorate remains constant in the temperature range of 20–40 °C and in the presence of 2.5 × 10−6–1 × 10−2 M NaNO3. The selectivity coefficients for perchlorate anion as test species with respect to other anions were determined. The proposed modified zeolite-PVC electrode can be used for at least 30 days without any considerable divergence in potential. It was applied as indicator electrode in water samples with satisfactory results. The results of this study and our previous work show HDTMA plays different roles according to the zeolite type and matrix, as HDTMA-zeolite Y in a carbon paste matrix showed a good Nernstian behavior towards phosphate anion.  相似文献   

11.
Trace chromium(VI) determination plays an important role since it is carcinogenic agent and toxic pollutant. For this purpose a direct method is developed using differential pulse polarography, DPP. When selenite was added into solutions of some ions such as copper(II), lead(II), cadmium(II), zinc(II), and chromium(VI) their DP polarographic peak decreased. This kind of interference will cause large errors in the determinations, its elimination is very important. The interference between selenite and Cr(VI) ions could be eliminated in B-R (Britton-Robbinson) buffer at pH 8.5. In this work the effect of components present in buffer has been investigated and it was found that phosphate and borate eliminated the formation of Cr–Se intermetallic compound formation. While it was possible to determine 1 × 10−5 M Cr(VI) in the presence of 100 times more selenite as (1.0 ± 0.1) × 10−5 M, in borate medium, it was possible to determine (1.0 ± 0.05) × 10−5 M in phosphate medium. In the presence of selenite detection limit (S/N = 3) was 9.0 × 10−8 M Cr(VI) by using either phosphate or borate This method was applied to Gerede river water, after oxidation all Cr(III) present into Cr(VI).  相似文献   

12.
A novel and reliable electrochemical sensor based on PbO2-carbon nanotubes-room temperature ionic liquid (i.e., 1-butyl-3-methylimidazolium hexafluorophosphate, BMIMPF6) composite film modified glassy carbon electrode (GCE) (PbO2–MWNT–RTIL/GCE) was proposed for simultaneous and individual determination of guanine and adenine. The guanine and adenine oxidation responses were monitored by differential pulse voltammetric (DPV) measurement. Compared with the bare electrode, the PbO2–MWNT–RTIL/GCE not only significantly enhanced the oxidation peak currents of guanine and adenine, but also lowered their oxidation overpotentials, suggesting that the synergistic effect of PbO2, MWNT and RTIL could dramatically improve the determining sensitivity of guanine and adenine. The PbO2–MWNT–RTIL/GCE showed good stability, high accumulation efficiency and enhanced electrocatalytic ability for the detection of guanine and adenine. Besides, the modified electrode also exhibited good behaviors in the simultaneous detection of adenine and guanine with the peak separation of 0.29 V in 0.1 M pH 7.0 phosphate buffer solution (PBS). Under the optimal conditions, the detection limit for individual determination of guanine and adenine was 6.0 × 10−9 M and 3.0 × 10−8 M (S/N = 3), respectively. The proposed method for the measurements of guanine and adenine in herring sperm DNA was successfully applied with satisfactory results.  相似文献   

13.
Voltammetric and electrochemical impedance spectroscopic (EIS) studies of generation one poly(propylene imine) (G1 PPI) dendrimer as an electroactive and catalytic nanomaterials both in solution and as an electrode modifier based on a simple one step electrodeposition method is presented. The G1 PPI exhibited a reversible one electron redox behaviour at E0′ ca 210 mV in phosphate buffer pH 7.2 with diffusion coefficient and Warburg coefficient of 7.5 × 10−10 cm2 s−1 and 8.87 × 10−4 Ω s−1/2 respectively. Cyclic voltammetric electrodeposition of a monolayer of G1 PPI on glassy carbon electrode was carried out between −100 mV and 1100 mV for 10 cycles. The nanoelectrode was electroactive in PBS at E0′ ca 220 mV. Kinetic profiles such as time constant (4.64 × 10−5 s rad−1), exchange current (1.55 × 10−4 A) and heterogeneous rate constant (4.52 × 10−3 cm s−1) obtained from EIS showed that the dendrimer layer catalysed the redox reaction of Fe2+/3+ in [Fe(CN)6]3−/4− redox probe.  相似文献   

14.
A sensitive and simplified voltammetric method is developed for the determination of trace amounts of vanadium(V) by adsorptive anodic stripping voltammetry using an acetylene black (AB) paste electrode. The method is based on the preconcentration of the V(V)–alizarin violet (AV) complex at open circuit while stirring the solution for 90 s in 0.15 mol dm−3 hexamethylenetetraamine–hydrochloric acid buffer (pH 4.4), the adsorbed complex is then oxidized, producing a response with a peak potential of 564 mV when scanning linearly from 0 to 1000 mV. For voltammetric determination of V(V), the parameters influencing the peak current have been optimized. Under the selected conditions, the peak current and concentration of V(V) accorded with linear relationship in the range of 8.0 × 10−10 mol dm−3–1.0 × 10−7 mol dm−3 (cAV = 2.0 × 10−6 mol dm−3) and 1.0 × 10−7 mol dm−3–8.0 × 10−6 mol dm−3 (cAV = 2.0 × 10−5 mol dm−3), the detection limit (three times signal to noise) was estimated to be 6.0 × 10−10 mol dm−3 for 90 s accumulation. The relative standard deviation (RSD) is 1.9% and 2.3% for V(V) concentrations of 1.0 × 10−7 mol dm−3 and 1.0 × 10−8 mol dm−3 respectively. Finally, this proposed method was successfully applied to the determination of V(V) in natural water samples.  相似文献   

15.
In the present paper, the use of a gold electrode modified by 2-(2,3-dihydroxy phenyl)-1,3-dithiane self-assembled monolayer (DPDSAM) for the determination of epinephrine (EP) and uric acid (UA) was described. Initially, cyclic voltammetry was used to investigate the redox properties of this modified electrode at various scan rates. The apparent charge transfer rate constant, ks, and transfer coefficient, α, were calculated. Next, the mediated oxidation of EP at the modified electrode was described. At the optimum pH of 8.0, the oxidation of EP occurs at a potential about 155 mV less positive than that of an unmodified gold electrode. The values of electron transfer coefficients (α = 0.356), catalytic rate constant (k = 1.624 × 104 M−1 s−1) and diffusion coefficient (D = 1.04 × 10−6 cm2 s−1) were calculated for EP, using electrochemical approaches. Based on differential pulse voltammetry, the oxidation of EP exhibited a dynamic range between 0.7 and 500.0 μM and a detection limit (3σ) of 0.51 μM. Furthermore, simultaneous determination of EP and UA at the modified electrode was described. Finally, this method was used for the determination of EP in EP ampoule.  相似文献   

16.
In this study, the electrochemical behavior of thianthrene (TH) and its application toward the electrocatalytic oxidation of guanosine (Gs) and DNA in a non-aqueous solution are investigated using different voltammetric techniques. Guanosine and DNA are adsorbed on the glassy carbon electrode (GCE) by applying a positive potential to the GCE. The rate constant of catalytic reaction between DNA and TH and also between Gs and TH were evaluated using chronoamperometry which gave rate constants of 2.41 × 106 cm3 mol−1 s−1 and 2.68 (±0.19) × 106 cm3 mol−1 s−1, respectively. Also the diffusion coefficient of TH was obtained using hydrodynamic voltammetry (3.17 × 10−5 cm2 s−1). Furthermore, using hydrodynamic voltammetry, a one-electron mechanism for oxidation of Gs is suggested.  相似文献   

17.
A comparison of the analytical performances of several enzyme biosensor designs, based on the use of different tailored gold nanoparticle-modified composite PVC/TTF-TCNQ electrodes, is discussed. The analytical characteristics of glucose calibration plots and kinetic parameters of the enzyme reaction were compared for the biosensors tested: Aucoll + GOx, GOx + Aucoll, Mixed GOx + Aucoll and PVC/TTF-TCNQ-Aucoll. The presence of this nanomaterial enhances the analytical performance with respect to the precursor biosensor without Au. The proposed biosensor can be applied in batch (response linear up to 2.0 mM, sensitivity of 45 ± 0.5 mA M−1 with a limit of detection, s/n = 3, of 6.2 × 10−6 M) and in FIA systems (linear range between 0.1 and 8 mM, sensitivity of 3.67 ± 0.3 mA M−1 with a limit of detection, s/n = 3, of 1.9 × 10−5 M).  相似文献   

18.
A functionalized carbon nanotubes paste electrode modified with cross-linked chitosan for the determination of trace amounts of cadmium(II) and mercury(II) by linear anodic stripping voltammetry is described. Under optimal experimental conditions, the peak current was linear in the Cd(II) concentration range from 5.9 × 10−8 to 1.5 × 10−6 mol L−1 with a detection limit of 9.8 × 10−9 mol L−1 and, for Hg(II) from 6.7 × 10−9 to 8.3 × 10−8 mol L−1with a detection limit of 2.4 × 10−9 mol L−1. The proposed method was successfully applied for the determination of Hg(II) in natural and industrial wastewater samples, and Cd(II) in sediments, human urine, natural, and industrial wastewater samples.  相似文献   

19.
A sensitive and selective method for determination of dopamine (DA) using multi-wall carbon nanotube (MWCNT)-poly(3,5-dihydroxy benzoic acid) [poly(DBA)] modified electrode is developed. The modified electrode shows excellent electrocatalytic activity toward the oxidation of dopamine in phosphate buffer solutions at pH 7.4. Using cyclic voltammetry, the linear range of 1 × 10−7–7.0 × 10−5 M in the interference of 500 μM ascorbic acid (AA) and the detection limit of 1.0 × 10−8 M were estimated for the measurement of DA in pH 7.4 phosphate buffer solutions. The value of DA current retained 98.36% of the initial response current after the modified electrode exposed to the air for one week. The interference studies showed that the modified electrode excludes effectively large excess of AA. The kinetic characteristics of the transfer of DA demonstrated that the electron propagation between DA and electrode was accelerated at MWCNT-poly(DBA) modified electrode. The work provided a valid and simple approach to selectively detect dopamine in the presence of AA in physiological environment.  相似文献   

20.
Electrochemistry of cytochrome c (cyt c) at biomimetic phospholipid layers was studied in a phosphate buffer solution, which were formed with dilauroyl phosphatidic acid (DLPA, C12:0), dipalmitoyl phosphatidic acid (DPPA, C16:0), distearoyl phosphatidic acid (DSPA, C18:0), and palmitoyl–oleoyl phosphatidic acid (POPA, C16:0–18:1). The lipid-layers formed firstly at the air/water interface were immediately transferred onto the electrode surface using the Langmuir–Blodgett (LB) technique. The electrochemical properties of cyt c at the lipid covered electrodes depended on the orientation, number of layers of phospholipids, tail (or head) group down, and vice versa. Atomic force microscopy (AFM) images of cyt c adsorbed on the POPA monolayer (showing the head group diameter of POPA to be ca. 0.7 nm) formed on highly oriented pyrolytic graphite (HOPG) displayed uniform surface morphology of lipid layer and clumps of aggregated cyt c molecules with a minimum size corresponding to four cyt c molecules. The heterogeneous electron transfer rate constants, k0 values, of cyt c were determined to be 1.02 × 10−3, 0.98 × 10−3, and 0.67 × 10−3 cm/s for the lipid monolayer in the tail down orientation (X-type) of POPA, DLPA, and DPPA, and 0.67 × 10−3 and 0.50 × 10−3 cm/s for the head down orientation (Z-type) of POPA and DLPA monolayers, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号