首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Lu X  Zhang X 《Health physics》2006,91(6):619-623
22Rn air concentrations in the Lantian Xishui karst cave of Shaanxi, China, were measured by continuous monitoring during a complete annual cycle (March 2004-February 2005) and annual doses for tour guides and visitors were estimated. The 22Rn air concentrations in the cave vary between a minimum of 383.6 Bq m(-3) and a maximum of 2,015.7 Bq m(-3), with an annual average of 1,100.4 Bq m(-3). Distinct seasonal variation of radon air concentrations inside the cave was observed. The maximum average radon concentration occurred in summer and the minimum average radon concentration occurred in winter. The annual effective dose to tour guides varies between an average of 1.2 mSv and 4.9 mSv depending on different equilibrium factors together with different dose conversion factors proposed in the literature, which is lower than the international recommendations. In all cases, the annual effective doses to visitors are well under the 1 mSv maximum suggested dose for a member of the public for one year.  相似文献   

2.
The present study's objective was to control the quality of different mitigation methods for unusually high indoor radon (222Rn) concentrations of up to 274,000 Bq m(-3) in a village (Umhausen, 2,600 inhabitants) in western Tyrol, Austria. Five years after mitigation, five different remedial actions were examined on their quality by means of measuring indoor radon concentrations with charcoal liquid scintillation radon detectors and with a continuously recording AlphaGuard detector. Mitigation method in house 1--a mechanical intake and outlet ventilation system with heat exchanger in the basement, combined with a soil depressurization system--was characterized by long-term stability. With most favorable air pressure (+100 Pa) in the basement, mean basement radon concentrations in the winter were reduced from 200,000 Bq m(-3) to 3,000 Bq m(-3) by this method 5 y after mitigation. Acting against experts' instructions, the inhabitants had switched off the ventilation system most of the time to minimize power consumption although it had been proven that ventilation reduced mean basement radon concentration by a factor of about 3 in the winter and about 15 in the summer. Mitigation method in house 2-soil depressurization with two fans and loops of drainage tubes to withdraw radon from the region below the floor and outside the basement walls, and from soil below that part of the house with no basement-had been the most successful remedial measure until the winter of 1999 (i.e., 6 y after mitigation), when micro-cracks opened and consequently mean basement radon concentration increased from 250 Bq m(-3) to 1,500 Bq m(-3). Measures to block these microcracks and to minimize soil drying are being developed. Five years after mitigation, the remedial method used in house 3--a multilayer floor construction, where a fan was used to suck radon from a layer between bottom slab and floor-reduced winter mean radon concentration from 25,000 Bq m(-3) to 1,200 Bq m(-3), with the ventilation on and the basement door open. Mitigation method in house 4--a basement sealing technique--was unsuccessful with almost identical radon concentrations during all the five years since mitigation had started. Mitigation method in house 5--a waterproof basement technique especially for future homes--reduced mean basement radon concentration below 300 Bq m(-3) and mean ground floor radon concentration below 200 Bq m(-3), which is the Austrian action level for newly constructed buildings. These findings indicate that even in areas with extremely high radon concentrations, effective mitigation of indoor radon can be achieved provided that house-specific long-term, stable mitigation techniques are applied.  相似文献   

3.
Indoor air radon concentrations are still unknown in Tunisia. For the first time, they have been determined in several regions of the country using open alpha track dosimeters containing LR-115 film. Measurements were taken in 69 dwellings located around greater Tunis during 1 y, changing dosimeters every 2 mo. In 12 other locations, devices were placed during 2 winter months. The median of 1,217 measurements was 40 Bq m(-3) and 93.4% of them were less than 100 Bq m(-3). The highest concentration was 392 Bq m(-3). In Tunis, concentrations were higher during winter. Indoor air radon figures varied with geographic location: the highest values were found in Jendouba, Gafsa, Beja, and Tataouine government districts where phosphate and lead mines and deposits are present. This first study showed that indoor air radon concentrations are low in Tunisia, but further studies should be performed in localized areas, taking into consideration the geology, the climatic variations, and the building material.  相似文献   

4.
During the winter months of 1992/93 and 1993/94, instantaneous indoor radon concentrations and gamma dose rates were measured in 890 schools in Slovenia attended in total by about 280,000 pupils. Under "closed conditions," the room to be surveyed was closed for more than 12 h prior to sampling, the air was sampled into alpha scintillation cells with a volume of 700 cm3, and alpha activity was measured. An arithmetic mean of 168 Bq m(-3) and a geometric mean of 82 Bq m(-3) were obtained. In 67% of schools, indoor radon concentrations were below 100 Bq m(-3), and in 8.7% (77 schools with about 16,000 pupils) they exceeded 400 Bq m(-3), which is the proposed Slovene action level. In the majority of cases, radon concentrations were high due to the geological characteristics of the ground. Approximately 70% of schools with high radon levels were found in the Karst region. Gamma dose rates were measured using a portable scintillation counter. An arithmetic mean of 102 nGy h(-1) and a geometric mean of 95 nGy h(-1) were obtained. No extraordinarily high values were recorded.  相似文献   

5.
Soto J  Gómez J 《Health physics》1999,76(4):398-401
Recent international recommendations have included exposure to natural radiation as one of the sources to monitor in certain occupationally exposed groups. Among those mentioned are workers in thermal spas, who may be exposed to high radiation doses due to the high concentration of radon in the indoor air of the spa. This paper presents the methodology and the results of an evaluation of radiation doses to the staff in different thermal spas in Spain. Different series of samples were collected and measurements made for the radon concentrations in water in 54 spas and in air in 20 spas. In six of the latter group, the air radon concentration was studied in different working areas occupied by the employees. The radon concentrations in water were between <2 and 775 x 10(3) Bq m(-3). The radon concentrations in air were between <10 and 5,200 Bq m(-3). The latter were used to estimate the dose received by each occupational group in the spa by taking into account the radon concentration in their main working area. By means of an exposure-dose conversion factor of 1.43 Sv per J h m(-3), the estimated effective doses were found to lie between 1 and 44 mSv y(-1). This upper limit is higher than the recommended annual limit of 20 mSv y(-1) for an occupational dose.  相似文献   

6.
The survey of 222Rn concentration in the air of tunnels constructed during World War II has been performed using a solid-state nuclear track detector technique. For the practical application of this technique to the determination of 222Rn concentrations in air, some basic properties were experimentally examined on the cellulose nitrate film, Kodak LR 115 type II. The calibration coefficient of the cellulose nitrate film used is determined from a correlation between the 222Rn concentration in air and the observed number of perforated etched tracks for widespread radon concentrations. The slope of the linear relationship observed yields a calibration coefficient of (0.00209 +/- 0.00018) tracks cm(-2) (Bq m(-3) h)(-1). From the survey of 222Rn concentration in the air of tunnels, the concentration of several thousand Bq m(-3) was observed at the inner most area of the tunnel, and the seasonal variation was clearly observed. The exponential distribution of radon concentration as a function of distance from the openings of the tunnel suggests that the radon concentration in the tunnel is basically governed by diffusion and mixing of radon gas with air.  相似文献   

7.
Indoor radon measurements were carried out in 300 dwellings in Kuwait using duplicate sets of charcoal detectors. Measurements were made at three different locations in the dwellings: living rooms, bedrooms, and basements. The results show that the radon concentration in the dwellings of Kuwait was found to vary in the range of 4.0-241.8 Bq m(-3) with a mean value of 32.8 Bq m(-3), and most values are confined within the range of 10-50 Bq m(-3) for all locations with few cases above the value of 100 Bq m(-3). Overall results show that the indoor radon concentration levels in Kuwait are relatively low, which is attributed to the use of air conditioning in summer and possible natural ventilation in winter. The radon concentration in basements was found to be relatively higher when compared to other rooms of the dwellings.  相似文献   

8.
Some 1,100 residences and places of work and 400 schoolrooms in Israel were tested for ambient air radon activity concentration in response to requests by the owners, tenants, or local authorities. A polyethylene vial containing activated charcoal was exposed to room air in each of these structures for 7 days, sealed, and transported to the laboratory. Adsorbed radon was extracted with a toluene-based cocktail which was then subjected to liquid scintillation counting. Mean radon activity concentrations were found to vary from city to city by more than an order of magnitude, indicating strong regional differences. The countrywide geometric mean was found to be 38 Bq/m3; the median, 37. The range for these means was 6-77 Bq/m3; for the medians, 11-100 Bq/m3. The highest reading was 9,100 Bq/m3. Our results are basically in line with those from the United States and much of Europe, but apparently higher than those found in the United Kingdom and Japan. It may be fairly said that mass testing for radon (222Rn) inside buildings in the United States began in the wake of the finding of a radon activity concentration in excess of 100,000 Bq/m3 in the home of the Watras family in Boyertown, PA in December 1984. To date, literally millions of American buildings have been tested, and mandatory testing of schoolrooms has begun in some states. In Israel, by contrast, where such a dramatically high measurement has not (yet) occurred, only 5 structures had been checked for radon by 1989.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
This paper presents the results of a survey of radon concentrations in Irish primary and post-primary schools. The objective of this survey was to assess the distribution of radon in Irish schools and to identify those requiring remedial work to reduce radon exposure to children and staff. All primary and post-primary schools were invited to participate in the survey. Indoor radon concentrations were measured during the academic year using integrating passive alpha track-etch detectors with a measurement period from three to nine months. The survey was carried out on a phased basis from 1998 to 2004 and is one of the most comprehensive of its kind undertaken in Europe. Measurements were completed in 38 531 ground floor classrooms and offices in 3826 schools, representing over 95% of the approximate 4000 primary and post-primary schools in Ireland. Of these, 984 schools had radon concentrations greater than 200 Bq m(-3) in 3028 rooms and 329 schools had radon concentrations in excess of 400 Bq m(-3) in 800 rooms. The average radon concentration in schools was 93 Bq m(-3). This results in an annual average effective dose to an Irish child from exposure to radon of 0.3 mSv per year, assuming that the long-term radon concentration is equal to the radon concentration present during the working hours and that the annual average occupancy is 1000 h per year. A programme of remediation of schools with radon concentrations above 200 Bq m(-3) has been put in place.  相似文献   

10.
An advisory reference level of 200 Bq m(-3) and a statutory reference level of 400 Bq m(-3) apply to radon exposure in Irish schools. Following the results of a national survey of radon in Irish schools, several hundred classrooms were identified in which the reference levels were exceeded and a remediation program was put in place. This paper provides an initial analysis of the effectiveness of that remediation program. All remediation techniques proved successful in reducing radon concentrations. Active systems such as radon sumps and fan assisted under-floor ventilation were generally applied in rooms with radon concentrations above 400 Bq m(-3). These proved most effective with average radon reduction factors of 9 to 34 being achieved for radon sumps and 13 to 57 for fan assisted under-floor ventilation. Both of these techniques achieved maximum radon reduction factors in excess of 100. The highest average reduction factors were associated with the highest initial radon concentrations. Passive remediation systems such as wall and window vents were used to increase background ventilation in rooms with radon concentrations below 400 Bq m(-3) and achieved average radon reductions of approximately 55%. Following the installation of active remediation systems, the radon concentration in adjacent rooms, i.e., rooms in which the radon concentration was already below 200 Bq m(-3) and therefore did not require remediation, was further reduced by an average of 25%. The long-term effectiveness of a number of radon sump systems with at least three years operation showed no evidence of fan failures. This study showed an apparent increase in sump effectiveness with time as indicated by an increase in radon reduction factors during this period.  相似文献   

11.
In India, out of about 0.7 million miners, nearly 0.5 million persons are directly engaged in coal operations. Radon and its progeny levels have been quantified in the coal-mining environment of Godavarikhani, Andhra Pradesh, India using solid-state nuclear track detectors. Seasonal and mine depth variations in radon levels have been recorded resulting in the identification of locations with a high radon level as areas with no mining activity, active mining operational zones and return air ventilation paths. All these radon levels were below the permissible levels. The average concentrations of radon and its progeny levels were found to be 144 +/- 61 Bq m(-3) and 20 +/- 11 mWL (working level) respectively in the two-incline mine, and these values for the five-incline mine are recorded as 315 +/- 71 Bq m(-3) and 30 +/- 9 mWL respectively.  相似文献   

12.
Due to the specific work regime in the Postojna Cave, which depends primarily on the daily number of visitors, and on seasonal variations in air radon concentrations, an optimal methodology for radon and progeny measurement and dose calculation was sought. The program of measurement throughout the years was optimized, and now comprises 3-mo exposures of etched-track detectors, and twice a year, 8-10-d measurements using continuous monitors. Radon concentrations range from about 500 Bq m(-3) in winter to about 6,000 Bq m(-3) in summer, and equilibrium factors range from 0.42 to 0.69 in winter and from 0.33 to 0.86 in summer. Radiation doses from radon decay products for employees in the cave were calculated according to the ICRP 65 methodology. The basic input data are radon concentrations and equilibrium factors at two selected locations in the cave and the records of the time spent by a worker in the cave. Effective doses received by employees annually ranged from 0.02 to 8.4 mSv.  相似文献   

13.
Indoor radon concentrations were measured in different seasons in 104 dwellings located on a highly permeable ice-marginal moraine in Kinsarvik, Western Norway. The measurements revealed the highest indoor radon levels ever detected in Norway and extreme variations in seasonal and short-term indoor radon levels. Annual average indoor radon concentrations up to 56 000 Bq m(-3) and a mean value of 4340 Bq m(-3) for the whole residential area are reported. By using the ICRP conversion factors to effective dose, these indoor radon values correspond to a total annual effective dose of 930 mSv and 72 mSv, respectively. By using the conversion as recommended by UNSCEAR, the effective doses would be about 50% higher. The indoor radon concentrations are found to be strongly influenced by thermally induced flows of radon-bearing soil air directed towards the upper part of the ice-marginal deposit in winter and towards the area of lowest elevation in summer. The pattern of seasonal variations observed suggests that in areas where thermal convection may occur, annual average indoor radon levels should be derived from measurements performed both in summer and in winter.  相似文献   

14.
Nationwide survey of radon levels in Korea   总被引:2,自引:0,他引:2  
Kim CK  Lee SC  Lee DM  Chang BU  Rho BH  Kang HD 《Health physics》2003,84(3):354-360
A nationwide radon survey was conducted to provide data on the annual average indoor radon concentration in Korean homes. This survey also provided data on the variation of radon concentration with season, house type, and building age. The arithmetic mean (AM) of annual radon concentration in Korean homes was 53.4 +/- 57.5 Bq m(-3). The indoor radon concentration showed a lognormal distribution with a geometric mean (GM) and its standard deviation (GSD) of 43.3 +/- 1.8 Bq m(-3). The radon concentrations in the traditional Korean-style houses were about two times higher than those in apartments and row houses. The average annual outdoor radon concentration was 23.3 Bq m(-3). The average annual effective dose to the general public from radon was 1.63 mSv y(-1).  相似文献   

15.
Radon action level for high-rise buildings   总被引:1,自引:0,他引:1  
Leung JK  Tso MY  Ho CW 《Health physics》1999,76(5):537-543
Radon and its progeny are the major contributors to the natural radiation dose received by human beings. Many countries and radiological authorities have recommended radon action levels to limit the indoor radon concentrations and, hence, the annual doses to the general public. Since the sources of indoor radon and the methods for reducing its concentration are different for different types of buildings, social and economic factors have to be considered when setting the action level. But so far no action levels are specifically recommended for cities that have dwellings and offices all housed in high-rise buildings. In this study, an optimization approach was used to determine an action level for high-rise buildings based on data obtained through previous territory-wide radon surveys. A protection cost of HK$0.044 per unit fresh air change rate per unit volume and a detriment cost of HK$120,000 per person-Sv were used, which gave a minimum total cost at an action level of 200 Bq m(-3). The optimization analyses were repeated for different simulated radon distributions and living environment, which resulted in quite significantly different action levels. Finally, an action level of 200 Bq m(-3) was recommended for existing buildings and 150 Bq m(-3) for newly built buildings.  相似文献   

16.
Residential radon has been shown to be a risk factor for lung cancer in several studies-but with limited power in each single study. The data of two case-control studies performed during 1990-1997 in Germany and used for previous publications have been extended and pooled. Both studies have identical study designs. In total, data of 2,963 incident lung cancer cases and 4,232 population controls are analyzed here. One-year radon measurements were performed in houses occupied during the 5-35 y prior to the interview. Conditional logistic and linear relative risk regression was used for the analysis. Measurements covered on average 70% of the exposure time window, with an average radon exposure of 61 Bq m(-3). The smoking and asbestos-adjusted ORs were 0.97 [95% confidence interval (CI) 0.85 to 1.11] for 50-80 Bq m(-3), 1.06 (95% CI 0.87 to 1.30) for 80-140 Bq m(-3) and 1.40 (95% CI 1.03 to 1.89) for radon concentrations above 140 Bq m(-3), compared to the reference category <50 Bq m(-3). The linear increase in the odds ratio per 100 Bq m(-3) was 0.10 (95% CI -0.02 to 0.30) for all subjects and 0.14 (95% CI -0.03 to 0.55) for less mobile subjects who lived in only one home in the last 5-35 y. The risk coefficients generally were higher when measurement error in the radon concentrations was reduced by restricting the population. With respect to histopathology, the risk for small cell carcinoma was higher than for other subtypes. This analysis strengthens the evidence that residential radon is a relevant risk factor for lung cancer.  相似文献   

17.
A radon survey has been carried out of indoor radon concentrations in dwellings located in the town of Metsovo, in north-western Greece. To measure indoor radon concentrations, CR-39 detectors were installed in randomly selected houses and were exposed for about 3 mo, during summer and winter. Gamma spectroscopy measurements of the soil's radium content also were performed. The indoor radon concentration levels varied from 17.6 to 750.4 Bq m(-3), while the radium concentration of soil varied from 4.9 to 97.1 Bq m(-3). Seasonal variation of the radon levels and the influence of house features and soil are discussed.  相似文献   

18.
长沙市室内装修及空气污染情况的调查   总被引:1,自引:0,他引:1  
目的 了解长沙市城区居室装修材料及住户入住后出现的不良症状,比较装修后不同时期居室空气污染情况。方法 预先设计调查表对装修材料及住户主诉情况进行调查登记,然后现场测定居室中甲醛和氡的浓度剂量。结果 城区装饰材料以板材、粘合剂、涂料、油漆、稀释剂和石材(瓷砖)为主,不良症状以头痛乏力、咳嗽、眼鼻刺激症状及记忆力下降为主;对装修半年内、一年内和一年以上的居室中甲醛和氡的浓度进行测定,室内空气中甲醛和氡的浓度均以半年内浓度为高(均值分别为0.357mg/m^3和95.37Bq/m^3),一年以上浓度最低(均值分别为0.049mg/m^3和17.06Bq/m^3)。结论 长沙市城区居室装饰材料基本相同,装饰后的居室最好在一年以后入住。  相似文献   

19.
目的在既往调查的基础上,进一步了解当地居民、游客、治疗疾病的患者的洗浴模式等情况,并对当地的室内外氡浓度进行测量。方法采用ATD短期累积测量法和连续测量法测量室内外氡浓度,并与国家相关标准进行对比。结果室内外氡浓度几乎全部高于电离辐射防护与辐射源安全基本标准(GB18871-2002)中的住宅中氡持续照射的优化行动水平400Bq/m3(平衡因子0.4)。部分浴室中氡浓度高于地热水应用中放射卫生防护标准(GBZ124-2002)中地热水浴疗室平衡当量氡浓度400Bq/m3的控制限值。结论降札温泉室内外氡浓度水平非常高,会对附近的居民、游客和患者的健康造成影响。  相似文献   

20.
Residential radon and risk of lung cancer in Eastern Germany   总被引:2,自引:0,他引:2  
BACKGROUND: There is suggestive evidence that residential radon increases lung cancer risk. To elucidate this association further, we conducted a case-control study in Thuringia and Saxony in Eastern Germany during 1990-1997. METHODS: Histologically confirmed lung cancer patients from hospitals and a random sample of population controls matched on age, sex and geographical area were personally interviewed with respect to residential history, smoking, and other risk factors. One-year radon measurements were performed in houses occupied during the 5-35 years prior to the interview. The final analysis included a total of 1,192 cases and 1,640 controls. Odds ratios (OR) and 95% confidence intervals (CI) were estimated by logistic regression. RESULTS: Measurements covered on average 72% of the exposure time window, with mean radon concentrations of 76 Bq/m3 among the cases and 74 Bq/m3 among the controls. The smoking- and asbestos-adjusted ORs for categories of radon (50-80, 80-140 and >140 Bq/m*3, compared with 0-50 Bq/m3) were 0.95 (CI = 0.77 to 1.18), 1.13 (CI = 0.86 to1.50) and 1.30 (CI = 0.88 to 1.93). The excess relative risk per 100 Bq/m? was 0.08 (CI = -0.03 to 0.20) for all subjects and 0.09 (CI = -0.06 to 0.27) for subjects with complete measurements for all 30 years. CONCLUSIONS: Our data indicate a small increase in lung cancer risk as a result of residential radon that is consistent with the findings of previous indoor radon and miner studies.  相似文献   