首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Acetabular cup placement in total hip arthroplasty (THA) has been recognized as an important factor in operative success, and accurate cup placement has been the impetus for novel medical technologies.

Methods

This article examines the cup placement in 955 THAs using a freehand Direct Anterior Approach on a standard operating table. Acetabular anteversion and inclination were determined using the circle theorem. Measurements were divided into safe zone placement determined by Callanan et al as 5°-25° for anteversion and 30°-45° for inclination, as well as by Lewinnek et al as 5°-25° for anteversion and 30°-50° for inclination. Dislocation rate was determined and correlated to safe zone placement.

Results

Although technology has advanced for cup placement, this investigation shows that a freehand technique demonstrates 0.31% dislocation after THA with an accuracy of 85% for the Lewinnek safe zone and 61% for Callanan, potentially because of the sparing of the posterior hip capsule.

Conclusion

The direct anterior approach to the hip on a regular operating table is safe and reliable. Our results demonstrate improvement in cup positioning compared with other freehand techniques. Surgeon awareness and control of the position of the pelvis within space optimizes acetabular component accuracy and precision without the need for special equipment, such as intraoperative fluoroscopy.  相似文献   

2.

Background

Movement of the pelvis during implantation of total hip arthroplasty (THA) has a major influence on the positioning of the acetabular cup. Strong traction caused by retractors leads to iatrogenic pelvic lift and can thus be partly responsible for cup malpositioning. The objective of this study was to investigate such factors that influence pelvic lift.

Methods

The dynamic movement of the pelvis was measured during implantation of THA in 67 patients. This was done by measuring the acceleration using the SensorLog app on a smartphone.

Results

At its maximum, the pelvis was lifted by an average of 6.7°. When impacting the press-fit cup, the surgical side was raised by 4.4° compared with the time of skin incision. This lift at the time of cup implantation correlates significantly with the body mass index and the patient's abdominal and pelvic circumference.

Conclusion

Every surgeon performing THA must be aware of the pelvic lift during an operation. Especially in patients with a high body mass index, a large abdominal circumference, or a large pelvic circumference, there is an increased risk of malpositioning of the acetabular cup. When impacting the cup, we recommend releasing the traction of the retractor, so that the pelvis can tilt back into its natural position, and thus, the anticipated cup positioning can be implemented as exactly as possible.  相似文献   

3.

Background

The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide.

Methods

The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators.

Results

The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P < .0001). The discrepancies from the targeted angles were 3.5° ± 3.1° for the inclination angle and 4.6° ± 3.4° for the anteversion angle in the conventional group and 2.3° ± 2.3° and 3.2° ± 2.7°, respectively, in the mechanical navigator group (P = .020, P = .012).

Conclusion

The mechanical cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position.  相似文献   

4.

Background

Given the lack of studies of acetabular defect reconstruction in primary total hip arthroplasty (THA) using tantalum augments, this study aims to evaluate clinical and radiographic results for treatment with tantalum augments to reconstruct acetabular defects in primary THA.

Methods

We retrospectively reviewed 19 patients (19 hips) with acetabular defects who underwent primary THA using tantalum augments, with a minimum follow-up of 2 years. Clinical, radiographic, and surgical data were retrospectively evaluated.

Results

Mean follow-up was 5.1 years (range 2.5-7.6). Harris Hip Score improved from 35.8 (range 19-56) preoperatively to 85.3 (63-98) at last follow-up (P < .01). Oxford Hip Score, University of California Los Angeles activity scale, and Short Form-12 score also improved significantly from presurgery to last follow-up. Mean operation time and blood loss were 124.7 minutes and 530 mL, respectively. Mean hip center position was 2.97 cm (range 2.35-3.58) horizontally and 2.06 cm (1.29-2.92) vertically, and mean acetabular inclination was 38.9° (range 27°-47°) at last follow-up. These parameters were not significantly different from those recorded immediately postoperatively (P > .05). There was no aseptic loosening, cup and augment migration, screw breakage, or presence of hip infection at last follow-up. All hips were radiographically stable.

Conclusion

Porous tantalum augments combined with titanium shells lead to satisfactory clinical and radiographic outcomes for the reconstruction of acetabular defect in primary THA at a mean 5.1 years of follow-up. This approach confers anatomical cup placement, simple operation, and a high rate of stable fixation.  相似文献   

5.

Background

Accurate cup positioning is one of the most challenging aspects of total hip arthroplasty (THA). Undetected movement of the patient during THA surgery can lead to inaccuracies in cup anteversion and inclination, increasing the potential for dislocation and revision surgery. Investigations into the magnitude of patient motion during THA are not well represented in the literature.

Methods

We analyzed intraoperative pelvic motion using a novel navigation device used to assist surgeons with cup position, leg length, and offset during THA. This device uses an integrated accelerometer to measure motion in 2 orthogonal degrees of freedom. We reviewed the data from 99 cases completed between February and September 2016.

Results

The mean amount of pitch recorded per patient was 2.7° (standard deviation, 2.2; range, 0.1°-9.9°), whereas mean roll per patient was 7.3° (standard deviation, 5.5; range, 0.3°-31.3°). Twenty-one percent (21 of 99) of patients demonstrated pitch of >4°. Sixty-nine percent (68 of 99) of patients demonstrated >4° of roll, and 25% (25 of 99) of patients demonstrated roll of ≥10°.

Conclusion

Our findings indicate that while the majority of intraoperative motion is <4°, many patients experience significant roll, with a large proportion rolling >10°. This degree of movement has implications for acetabular cup position, as failure to compensate for this motion can result in placement of the cup outside the planned safe zone, thus, increasing the potential for dislocation. Further study is warranted to determine the effect of this motion on cup position, leg length, and offset.  相似文献   

6.

Background

The rate of and the reasons for the failure of metal-on-metal (MoM) bearings have recently been discussed in literature. The aim of this study was to evaluate the influence of acetabular cup inclination and version angles on revision risk in patients with MoM hip arthroplasty.

Methods

We retrospectively reviewed 825 patients (976 hips) who underwent a MoM hip arthroplasty between 2000 and 2013. There were 474 men and 351 women, with a mean age of 58 (19-86) years. Acceptable cup orientation was considered to be inside the Lewinnek's safe zone.

Results

The mean acetabular inclination angle was 48.9° (standard deviation, 8.1°; range, 16°-76°) and version angle 20.6° (standard deviation, 9.9°; range, ?25 to 46°). The cup was found to be outside the Lewinnek's safe zone in 571 hips (58.5%). Acetabular cup revision surgery was performed in 157 hips (16.1%). The cup angles were outside Lewinnek's safe zone in 69.2% of the revised hips. The mean interobserver reliability and intraobserver repeatability of the measurements of cup inclination and version angles were excellent (intraclass correlation coefficients >0.90). The odds ratio for revision in hips outside vs inside the Lewinnek's safe zone was 1.82 (95% confidence interval, 1.26-2.62; P = .0014).

Conclusion

Our findings provide compelling evidence that a cup position outside the Lewinnek's safe zone is associated with increased revision risk in patients with MoM arthroplasty.  相似文献   

7.

Background

Changes in spinal alignment and pelvic tilt alter acetabular orientation in predictable ways, which may have implications on stability of total hip arthroplasty (THA). Patients with sagittal spinal deformity represent a subset of patients who may be at particularly high risk of THA instability because of postural compensation for abnormal spinal alignment.

Methods

Using standing stereoradiography, we evaluated the spinopelvic parameters, acetabular cup anteversion, and inclination of 139 THAs in 107 patients with sagittal spinal deformity. Standing images were compared with supine pelvic radiographs to evaluate dynamic changes in acetabular cup position. Dislocation and revision rates were procured through retrospective chart review. The spinal parameters and acetabular cup positions among dislocators were compared with those who did not dislocate.

Results

The rate of THA dislocation in this cohort was 8.0%, with a revision rate of 5.8% for instability. Patients who sustained dislocations had significantly higher spinopelvic tilt, T1-pelvic angle, and mismatch of lumbar lordosis and pelvic incidence. Among all patients, 78% had safe anteversion while supine, which decreased significantly to 58% when standing due to increases in spinopelvic tilt. Among dislocating THA, 80% had safe anteversion, 80% had safe inclination, and 60% had both parameters within the safe zone.

Conclusion

In this cohort, patients with THA and concomitant spinal deformity have a particularly high rate of THA instability despite having an acetabular cup position traditionally thought of as within acceptable alignment. This dislocation risk may be driven by the degree of spinal deformity and by spinopelvic compensation. Surgeons should anticipate potential instability after hip arthroplasty and adjust their surgical plan accordingly.  相似文献   

8.

Background

We evaluated acetabular cup coverage (CC) and rim contact (RC) to evaluate the bone stock above the acetabulum for guiding acetabular component placement using the high hip center technique in patients with Crowe type III developmental dysplasia of the hip.

Methods

Using hip computed tomography and image processing software, pelvises were reconstructed digitally in 20 hips with Crowe type III developmental dysplasia of the hip. Mimicked cup was placed with anteversion angles of 0° (group I), 5° (group II), and 10° (group III) respectively. In each group, the cup was placed at the anatomical hip center at first, and then the cup was moved up to 40 mm vertically about the native rotation center with an increment of 2.5 mm at each step. CC and RC were calculated and documented with each movement.

Results

CC was 65.87%, 67.77%, and 68.98% for group I, group II, and group III at the native rotation center, and increased progressively to 86.45%, 85.85%, and 84.71% at 25 mm above. RC was 49.17%, 50.25%, and 51.92% for group I, group II, and group III at the native rotation center, and increased progressively to 86.87%, 86.39%, and 84.94% at 22.5 mm above. CC and RC were positively correlated, despite the different anteversion angles (r = 0.687 at 0°, 0.683 at 5°, and 0.645 at 10°; P < .001).

Conclusion

Computed tomography analysis and computer stimulation demonstrate that it is feasible to use high hip center technique in Crowe type III hips.  相似文献   

9.

Background

Due to anterior bone defects, high and/or posterior placement of an acetabular cup is often required to achieve sufficient coverage in patients with hip dysplasia. We examined whether posterior cup placement affected the postoperative range of motion (ROM) in primary total hip arthroplasty (THA).

Methods

Using computer software, bone coverage and ROM were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. We determined the cup position to satisfy cup center-edge (Cup-CE) angle ≥0° and the required ROM. The cup was placed at the anatomic hip center and moved in 2-mm increments anteroposteriorly and 10-mm increments vertically.

Results

At vertical anatomic hip center, less than 68.8% hips fulfilled Cup-CE ≥0° regardless of anteroposterior position. Significantly more hips at higher hip center with posterior cup placement achieved Cup-CE ≥0° than hips at vertical anatomic hip center, and 10 mm higher hip center was the most suitable for achieving bone coverage. However, posterior and superior cup placement significantly decreased the flexion and IR due to early bone impingement, whereas ER and extension were not affected. A smoothing spline curve demonstrated that more posterior cup placement than 4.8 mm and 3.6 mm did not satisfy the required ROM at 10 mm and 20 mm higher hip center, respectively.

Conclusions

Posterosuperior cup placement gained more bone coverage but decreased the range of hip flexion and internal rotation. Consequently, posterosuperior cup placement did not satisfy the required ROM.  相似文献   

10.

Background

This study used EOS imaging of primary total hip arthroplasty (THA) patients, with and without predating spinal fusion, to investigate (1) the impact of spinal fusion on acetabular implant anteversion and inclination, and (2) whether more extensive spinal fusion (fusion starting above the thoracolumbar junction or extension of fusion to the sacrum) affects acetabular implant orientation differently than lumbar only spinal fusion.

Methods

Ninety-three patients had spinal fusion (case group), and 150 patients were without spinal fusion (controls). None of the patients experienced dislocation. The change in sacral slope (SS) and cup orientation from standing to sitting was measured.

Results

Mean SS change from the standing to sitting positions was ?7.9°in the fusion group vs ?18.4°in controls (P = .0001). Mean change in cup inclination from the standing to sitting positions was 4.9°in the fusion group vs 10.2°in controls (P = .0001). Mean change in cup anteversion from standing to sitting positions was 7.1°in the fusion group vs 12.1°in controls (P = .0001). For each additional level of spinal fusion, the change in SS from standing to sitting positions decreased by 1.6(95% confidence interval [CI], 2.2073-1.0741), the change in cup inclination decreased by 0.8(95% CI, 0.380-1.203), and the change in cup anteversion decreased by 0.9(95% CI, 0.518-1.352; P < .001 in all cases).

Conclusion

Patients with spinal fusion demonstrated less adaptability of the lumbosacral junction. Longer spinal fusion or inclusion of the pelvis in the fusion critically impacts hip-spine biomechanics and significantly affects the ability to compensate in the standing-to-sitting transition.  相似文献   

11.

Background

This study compares the differences in acetabular component position, leg length discrepancy, and hip offset between the anterior and posterior approach. A novel method is applied to determine the acetabular anteversion using the C-arm tilt angle for the anterior approach.

Methods

Hundred consecutive anterior total hip arthroplasties were matched according to gender, body mass index, and age to a cohort of 100 primary total hip arthroplasties operated on through a posterior approach. Postoperative radiographs were analyzed to determine cup inclination, cup anteversion, leg length discrepancy, and hip offset.

Results

The mean inclination was 40.8° (range 33°-48°) and 45.1° (range 33°-55°) for the anterior and posterior approach, respectively. Using the new C-arm tilt plane technique, an average acetabular anteversion of 18.4° (range 11°-26°) was achieved with the anterior approach compared with 23.6° (range 8°-38°) with the posterior approach. Hundred percent cups in the anterior group and 81% in the posterior group fell within the safe zone (P < .001). There was no difference in the overall hip offset between the operated side and the contralateral side for the anterior (P = .074) and posterior (P = .919) group. There was no difference in leg length discrepancy between the 2 approaches (P = .259).

Conclusion

Intraoperative fluoroscopy-assisted direct anterior approach was associated with improved acetabular component positioning. However, no benefit was shown with regards to restoration of hip offset or leg length.  相似文献   

12.

Background

The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation.

Methods

A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient.

Results

Anteversion significantly increased (P < .0001) a mean of 12° from supine (15.1° ± 10.4°) to standing (27.2° ± 10.5°) position. Inclination also significantly increased (P = .001) a mean of 2° from supine (44.4° ± 6.8°) to standing (46.3° ± 7.7°) position. There was no difference (P = .093) in wear rate between supine (0.067 ± 0.070 mm/y) and standing (0.073 ± 0.074 mm/y) positions. There were no correlations between cup orientation and wear rate in either position.

Conclusion

Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position.  相似文献   

13.

Background

The position of the acetabular component in total hip arthroplasty (THA) is critical for success. However, this remains the most variable aspect of the surgery. We hypothesized that there is wide variation in pelvic orientation in the lateral decubitus position. We sought to determine the variability in pelvic positioning and the frequency of pelvic malposition during THA in lateral decubitus with regard to pelvic tilt and pelvic rotation.

Methods

We analyzed preoperative standing and intraoperative anteroposterior pelvis X-rays in 248 consecutive THAs performed in lateral decubitus by one surgeon. Pelvic tilt and rotation were determined for preoperative and intraoperative X-rays. Proper intraoperative positioning was defined as less than 10° change in tilt or rotation between preoperative and intraoperative X-rays.

Results

With regard to pelvic tilt, the intraoperative position was proper in 188 (76%) cases. There was a pelvic tilt discrepancy of 10°-20° in 43 (17.5%) cases and greater than 20° in 16 (6.5%) patients. With regard to pelvic rotation, the intraoperative position was proper in 202 (81%) cases. There was a pelvic rotation discrepancy of 10°-20° in 38 (15.4%) cases and greater than 20° in 7 (2.8%) cases. In 248 cases, only 154 (62.1%) had intraoperative positioning within 10° of preoperative tilt and axial rotation. Pelvic malposition occurred in 38% of cases overall.

Conclusion

There is wide variation in pelvic orientation in lateral decubitus and frequent discrepancy in pelvic tilt and rotation between preoperative and intraoperative anteroposterior X-rays. Anatomic landmarks should be used to guide acetabular component positioning.

Level of Evidence III

Diagnostic.  相似文献   

14.

Background

The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.

Methods

A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the “safe zone.”

Results

The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.

Conclusion

Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.  相似文献   

15.

Background

Malseating of ceramic liner appeared as a matter of concern in multibearing metal, although multibearing cup can be coupled with hard liners as well as polyethylene liner. In this metal shell, the inner taper angle should be 10° for the modularity, while standard metal shells for ceramic liner have an inner taper angle of 18°. However, there has been no study in the effect of taper angle to the risk of malseating. We evaluated whether the taper angle of metal shell might affect the malseating of ceramic liner, and dissociation force of ceramic liner from metal shell.

Methods

Three surgeons manually inserted ceramic liners into two designs of metal shell with different tapers angles (10° and 18°). We compared malseating rates of ceramic liners and push-out strengths, which means dissociation force of the ceramic liner from the metal shell, between these two metal shell designs.

Results

The malseating rates in 10° metal shell were higher than those in 18° metal shell (23.3% vs 0%, P < .05). The mean dissociation force (1148.8 ± 46.7 N) in 10° taper cup was higher than that (389.7 ± 108.3 N) in 18° taper cup (P < .01).

Conclusion

Our results suggest that surgeon should be cautious about malseating of ceramic liner when using multi-bearing metal shell with inner taper angle of 10°.

Clinical relevance

When surgeon use multi-bearing metal shell with inner taper angle of 10°, our results suggest that surgeon should be cautious about malseating of ceramic liner.  相似文献   

16.

Background

Functional anteversion and inclination of the cup change as the pelvic sagittal inclination (PSI) changes. The purposes of this study were to investigate the chronological changes of PSI during a 10-year follow-up period after total hip arthroplasty (THA) and to report the characteristics of patients who showed a greater than 10° change in the PSI from the supine to the standing position.

Methods

The subjects were 70 patients who were followed up for 10 years after THA. PSI values in the supine and standing positions were measured by 2D-3D matching using computed tomography images and pelvic radiographs. PSI values before THA and 1, 5, and 10 years after THA were compared in both the supine and standing positions.

Results

Supine PSI showed less than 5° of change, whereas standing PSI showed a significant decrease with time over the 10-year period. Although 43% of patients with less than 10° of difference in the PSI between the supine and standing positions before THA increased PSI posteriorly (reclining) more than 10° in standing from the supine position at 10 years, no late dislocation was observed.

Conclusion

Supine PSI showed no significant change, but standing PSI showed a significant increase posteriorly with time over a 10-year period. However, this PSI change did not reach the level that it caused negative consequences such as late dislocation. The pelvic position in the supine position might still be a good functional reference position of the pelvis for aiming to achieve proper cup alignment at 10 years.  相似文献   

17.

Background

Revision total hip arthroplasty (THA) is challenging specially in the presence of severe acetabular bone deficiency. We report the use of a highly porous revision shell augmented by structural allograft to provide structural support and coverage to the acetabular component.

Methods

We identified 56 patients (58 hips) undergoing revision THA, where a trabecular metal revision cup was supported by structural allograft. Mean follow-up was 5.4 years (range 2-12 years). Preoperatively acetabular bone defects were classified as Paprosky 2A in 6 hips (10%), 2B in 12 hips (21%), 2C in 12 hips (21%), 3A in 11 hips (19%), and 3B in 17 hips (29%). Structural allograft configuration was classified as type 1 (flying buttress) in 13 hips, type 2 (dome support) in 23 hips, and type 3 (footings) in 17 hips, with 5 hips having combined configurations.

Results

All hips showed evidence of union between the allograft and host bone at latest follow-up, 14 hips had partial resorption of the allograft that did not affect cup stability. Three acetabular components demonstrated failure of ingrowth. Survivorship-free from radiographic acetabular loosening as end point was 94% at 5 years. The 5-year survivorship with revision for any reason as end point was 90%.

Conclusion

Trabecular metal shells combined with structural bone allograft in revision THA demonstrate excellent midterm survival, with 94% of acetabular components obtaining stable union onto host bone at 5 years. Allograft restored bone stock with minimal resorption, and when it occurred did not alter the survivorship of the acetabular component.  相似文献   

18.

Background

Prediction of pelvic displacement before total hip arthroplasty (THA) is important for accurate acetabular implant placement. This study aimed to evaluate the effect of contralateral joint conditions on pelvic displacement after THA.

Methods

A total of 355 cases that underwent computed tomography before and after THA for osteoarthritis due to developmental dysplasia were assessed. The pelvic plane was based on preoperative and postoperative day 1 computed tomography images. The displacement in the anteversion direction was expressed as +. Subjects with a minimal joint space <2 mm in the contralateral hip joint were in group N; subjects with ≥2 mm were in group W; subjects with THA were in group P; and subjects who underwent THA simultaneously on both sides were in group B. The Bartlett test was used when conducting the equal variance test among the groups. The F test was used for pairwise comparison. A P value <.01 was considered statistically significant.

Results

Groups N, W, P, and B had 49, 227, 55, and 24 cases, respectively, and their displacements were ?0.2° ± 2.7°, 0.8° ± 3.9°, 0.5° ± 2.6°, and 1.1° ± 4.0°, respectively; the variance between the groups was significantly different (P = .0001). The differences between groups W and N (P = .0020), between groups W and P (P = .0003), and between groups P and B (P = .0086) were statistically significant.

Conclusion

When the contralateral joint space is wide, the variance of the displacement is high. The contralateral joint affects pelvic displacement.  相似文献   

19.

Background

Obesity has been described as an independent risk factor for acetabular component malpositioning. The purpose of this study was to determine if this could be overcome by use of fluoroscopic navigation in total hip arthroplasty (THA).

Methods

The first, postoperative, standing, anteroposterior pelvis radiographs from 1599 consecutive patients who underwent fluoroscopic-guided THAs via anterior approach during a six-year period were obtained. We retrospectively reviewed this prospectively collected data. Inclination and anteversion were measured as described by Barrack et al. Intraoperative target ranges for inclination and anteversion angles were 30°-50° and 5°-25°. Patients were divided into 3 cohorts by body mass index, nonobese (<30 kg/m2) obese (between 30 and 40 kg/m2) and morbidly obese (>40 kg/m2), looking for significant differences in acetabular component positioning.

Results

Of the 1599 patients, 1065 were nonobese, 506 obese, and 28 morbidly obese. Overall, average inclination was 37.7° and anteversion was 16.3°. Regarding inclination, 95.0% of cups were positioned in the safe zone, 95.7% for anteversion, and 91.2% for both inclination and anteversion. Analysis of each cohort individually revealed an average inclination of 37.5° in the nonobese, 37.9° in the obese, and 39.9° in the morbidly obese patients. For anteversion, each group's averages were 16.1°, 16.5°, and 16.0°, respectively. There was no significant relationship between a patient's body mass index and cup position for inclination (P = .867), anteversion (P = .673), or both inclination and anteversion (P = .624).

Conclusion

Fluoroscopy is a useful tool for achieving a targeted acetabular component orientation in direct anterior THA, irrespective of patient BMI.  相似文献   

20.

Background

Prevention of dislocation after primary total hip arthroplasty (THA) begins with patient preoperative assessment and planning.

Methods

We performed a literature search to assess historical perspectives and current strategies to prevent dislocation after primary THA. The search yielded 3458 articles, and 154 articles are presented.

Results

Extremes of age, body mass index >30 kg/m2, lumbosacral pathology, surgeon experience, and femoral head size influence dislocation rates after THA. There is mixed evidence regarding the effect of neuromuscular disease, sequelae of pediatric hip conditions, and surgical approach on THA instability. Sex, simultaneous bilateral THA, and restrictive postoperative precautions do not influence the dislocation rates of THA. Navigation, robotics, lipped liners, and dual-mobility acetabular components may improve dislocation rates.

Conclusions

Risks for dislocation should be identified, and measures should be taken to mitigate the risk. Reliance on safe zones of acetabular component positioning is historical. We are in an era of bespoke THA surgery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号