共查询到20条相似文献,搜索用时 46 毫秒
1.
Kerry Costi Lucian B. Solomon Margaret A. McGee Mark S. Rickman Donald W. Howie 《The Journal of arthroplasty》2017,32(4):1227-1233
Background
The risk of revision following primary total hip arthroplasty (THA) is increased in young patients who undergo THA for pathologies other than primary osteoarthritis. We report the results of primary THA performed with cemented polished stems in patients aged 40 years and younger for pathologies other than primary osteoarthritis.Methods
We investigated 52 patients (65 hips) who underwent primary THA for secondary osteoarthritis with a cemented tapered polished stem between 1990 and 2007. Clinical and radiographic outcomes, available in 46 patients (57 hips), included the Harris Hip Scores, Societe Internationale de Chirurgie Orthopedique et de Traumatologie activity, patient satisfaction, stem survival and reoperations, and assessment of prosthesis-cement-bone radiolucencies, osteolysis, and femoral bone deficiencies.Results
Median patient age was 34 years (16-40) and follow-up was 14 years (mean 13, range 5-22). Stem survival to the endpoint revision for loosening was 100% and to the endpoint revision for any reason, excluding infection was 88% (95% confidence interval 78-98) at 16 years. No stem was revised for aseptic loosening. Nine stems were revised for other reasons. Radiographically, one stem was definitely loose at 16 years. The median patient Harris pain score improved from marked pain to no pain at latest follow-up. Patient activity level improved, albeit minimally, for 8 years after surgery. At latest follow-up, 98% of the patients remained satisfied with their surgery.Conclusion
Primary THA with a cemented polished stem shows excellent results in young patients with pathology other than primary osteoarthritis. In addition, the stem design facilitates cement within cement exchange and therefore preservation of proximal femoral bone stock at revision surgery. 相似文献2.
Tanner W. Grant Luke R. Lovro David J. Licini Lucian C. Warth Mary Ziemba-Davis Robert M. Meneghini 《The Journal of arthroplasty》2017,32(3):891-897
Background
Femoral component stability and resistance to subsidence is critical for osseointegration and clinical success in cementless total hip arthroplasty. The purpose of this study was to radiographically evaluate the anatomic fit and subsidence of 2 different proximally tapered, porous-coated modern cementless femoral component designs.Methods
A retrospective cohort study of 126 consecutive cementless total hip arthroplasties was performed. Traditional fit-and-fill stems were implanted in the first 61 hips with the remaining 65 receiving morphometric tapered wedge stems. Preoperative bone morphology was radiographically assessed by the canal flare index. Canal fill in the coronal plane, subsidence, and the sagittal alignment of stems was measured digitally on immediate and 1-month postoperative radiographs.Results
Demographics and canal flare indices were similar between groups. The percentage of femoral canal fill was greater in the tapered wedge compared to the fit-and-fill stem (P = .001). There was significantly less subsidence in the tapered wedge design (0.3 mm) compared to the fit-and-fill design (1.1 mm) (P = .001). Subsidence significantly increased as body mass index (BMI) increased in the fit-and-fill stems, a finding not observed in the tapered wedge design (P = .013).Conclusion
An anatomically designed morphometric tapered wedge femoral stem demonstrated greater axial stability and decreased subsidence with increasing BMI than a traditional fit-and-fill stem. The resistance to subsidence, irrespective of BMI, is likely due to the inherent axial stability of a tapered wedge design and may be the optimal stem design for obese patients. 相似文献3.
Krishna R. Cidambi Steven L. Barnett Paige R. Mallette Jay J. Patel Nader A. Nassif Robert S. Gorab 《The Journal of arthroplasty》2018,33(3):800-804
Background
An increased rate of complications related to femoral component failure has been described with less invasive total hip arthroplasty (THA). This study evaluated the incidence of femoral complications associated with the direct anterior approach for THA.Methods
Retrospective review was performed of the initial 1120 consecutive patients who underwent direct anterior THA by 2 surgeons.Results
A total of 899 patients (80.3%) had a 2-year follow-up (range, 2-8 years). Complications within 90 days occurred in 20 patients (1.8%): 10 calcar fractures, 1 greater trochanter fracture, 1 canal perforation, 3 hematomas, 2 dislocations, 2 superficial, and 1 deep infection. Nine patients (1%) underwent revision: 5 for aseptic femoral loosening (0.55%), 1 for periprosthetic joint infection, 1 for dislocation, 1 for hip flexor irritation, and 1 for a damaged polyethylene liner.Of the 5 patients with aseptic femoral loosening, 3 had a short, mediolateral tapered stem, 1 cemented stem, and 1 S-ROM stem placed to bypass a canal perforation. There were no revisions for aseptic loosening in the collared, fully hydroxyapatite (HA)-coated compaction broached or triple tapered proximal fit and fill stem designs (70.6% of all stems). Revision rate for femoral loosening was significantly higher for tapered wedge over HA-coated, compaction broached stems (P < .005).Conclusion
Pain and function improved predictably with a 0.55% rate of femoral loosening at 2-year follow-up. Among collared, fully HA-coated and triple taper fit and fill femoral stems, there were no instances of revision for aseptic loosening vs 3 in the short stem, collarless mediolateral tapered group. 相似文献4.
Background
The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship.Methods
Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points.Results
The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point.Conclusion
The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. 相似文献5.
Ahmed El-Bakoury Hazem Hosny Mark Williams Jonathan Keenan Rathan Yarlagadda 《The Journal of arthroplasty》2017,32(2):541-545
Background
Periprosthetic fracture following total hip arthroplasty is a significant problem faced by hip surgeons, and its management in elderly patients remains a considerable challenge.Methods
We retrospectively reviewed 28 Vancouver B2 and B3 periprosthetic femoral fractures (PFF) treated with revision of the femoral stems by distally locked, hydroxyapatite-coated uncemented stems (Cannulok). Patients were aged 75 years or older at the time of surgery.Results
The mean follow-up was 44.6 months (range, 24-102). The mean postoperative Oxford hip score was 30.1 (range, 10-46). The rate of fracture union was 95.8%, and the survivorship of the stem was 100% at the end of follow-up.Conclusion
The management of PFF in elderly is associated with increased postoperative morbidity and mortality. The use of a distally locked, hydroxyapatite-coated femoral stem is a valid option for the treatment of PFF to achieve fracture union with a low rate of revision. 相似文献6.
Yong Huang Yixin Zhou Hongyi Shao Jianming Gu Hao Tang Qiheng Tang 《The Journal of arthroplasty》2017,32(10):3108-3113
Background
Both modular and nonmodular tapered fluted titanium stems are used in revision total hip arthroplasty (THA), with follow-up showing good results for both stems. We aimed to determine whether there were any differences in clinical outcomes, survivorship, or frequency of complications.Methods
A retrospective review of 160 consecutive THAs (153 patients) revised with a tapered fluted modular titanium stem from 2002 to 2014 and 129 consecutive THAs (128 patients) revised with a tapered fluted nonmodular titanium stem between 2008 and 2014 was conducted. The patient's level of satisfaction, clinical assessment, and complications were examined. A Kaplan-Meier survivorship analysis was performed with the endpoint defined as any reoperation due to septic/aseptic complications.Results
Mean duration of follow-up was longer in the modular group (6.3 years) than the nonmodular group (5.0 years; P = .003). No significant group differences were found in the postoperative Harris Hip Score, the level of overall satisfaction, the 8-year cumulative survival, the rate of infection, dislocation, or postoperative periprosthetic fractures. However, intraoperative fractures occurred significantly more frequently in the modular group (16.9%) than in the nonmodular group (7.0%; P = .011), and stem subsidence was significantly less in the modular group (0.95 mm) than in the nonmodular group (1.93 mm; P = .001). Two mechanical failures associated with the modular design occurred in the modular group.Conclusion
Both modular and nonmodular tapered fluted titanium stems provide satisfactory midterm results in revision THA. Although tapered fluted modular stems are gaining in popularity in revision THA, tapered fluted nonmodular stems should not be disregarded as a viable alternative, especially for relatively straightforward cases. 相似文献7.
Background
Femoral bone deficiency is a challenging problem in revision femoral arthroplasty in younger patients. We evaluated outcomes of revision femoral arthroplasty using a freeze-dried allograft prosthetic composite (APC).Methods
This was a retrospective review of 16 patients (12 men and 4 women) who had unilateral proximal femoral deficiencies (Paprosky type III B, 13 patients; type IV, 3 patients) revised with freeze-dried APC. Follow-up at mean 7 years included assessment with Merle D'Aubigné score and radiographs.Results
At follow-up, the average hip score was improved for pain, function, and range of motion. The 5-year graft survival was 87%, and the estimated median survival was 8.8 years. There were 3 patients who walked without support, 10 patients who walked unlimited distance with a cane, 2 patients who walked with 2 crutches, and 1 patient who walked with a walker. Radiographs showed nonunion at the graft-host junction in 3 hips (19%), but only 1 patient was symptomatic. Asymptomatic trochanteric nonunion was observed in 4 hips (25%). There was moderate graft resorption in 2 patients at 9 years after surgery and mild graft resorption in 1 graft at 7 years. There was subsidence of <2 cm in 2 patients and 3.5 cm in 1 patient.Conclusion
The present study showed acceptable results in treatment of major femoral deficiencies using freeze-dried APC in younger patients. Freeze-dried APC may be a useful for revision femoral arthroplasty. 相似文献8.
Trevor Scott Anthony Salvatore Pauline Woo Yuo-yu Lee Eduardo A. Salvati Alejandro Gonzalez Della Valle 《The Journal of arthroplasty》2018,33(4):1120-1125
Background
Cemented stems are designed to follow 1 of 2 principles of fixation: composite beams or slide taper. Stems in the latter category have a collarless, polished, tapered (CPT) design and subside into the cement mantle, creating hoop stresses. We compared the rate of periprosthetic fracture (PPF) of stem designed with these 2 principles of fixation. In addition, we examined radiographic factors that may predispose to the development of PPF.Methods
We retrospectively reviewed all patients who underwent primary THA by a single surgeon using highly polished cemented stems. PPF rates were compared between CPT stems (follow-up, 21 months; standard deviation [SD], 22) and composite beam stems (follow-up, 21.7 months; SD, 26). Demographic data were compared between patients with and without a PPF. Three preoperative radiographic parameters (canal bone ratio [CBR], canal-calcar ratio, and canal flare index), stem alignment, and cement mantle were compared in match-paired patients with and without a PPF (1:34).Results
Seven of 1460 THA patients developed a PPF (0.479%); 4 hips of 185 with a CPT stem (2.2%); and 3 of 1275 hips with a composite beam stem (0.23%; P = .0064). Three of the 4 PPFs in the CPT group and none in the composite beam group were classified as Vancouver B2. The CBR in patients with a PPF was 0.50 (SD, 0.07) and 0.43 (SD, 0.07) in the match cohort of hips without PPF (P = .013).Conclusion
CPT stems may be associated with a higher risk of PPF that often require reoperation. An increased CBR may be a risk factor for postoperative PPF. 相似文献9.
Background
Question arises as to whether rigid fixation of ultra-short anatomic or ultra-short non-anatomic proximal loading uncemented femoral stem can be obtained without diaphyseal stem fixation. The purpose of this study is to compare the short-term clinical results, radiographic results, revision and survival rates, and complication rates of ultra-short anatomic versus ultra-short non-anatomic uncemented femoral stems.Methods
This study consisted of 50 patients (56 hips) in the ultra-short anatomic uncemented stem group (mean age 61.4 ± 14.7 years) and 50 patients (56 hips) in the ultra-short non-anatomic uncemented stem group (mean age 59.5 ± 15.2 years). The mean follow-up was 3.4 years (range 3-4) in the ultra-short anatomic stem group and 3.5 years (range 3-4) in the ultra-short non-anatomic stem group.Results
At the final follow-up, the mean Harris hip scores (92 vs 93 points), Western Ontario and McMaster Universities Osteoarthritis scores (16 vs 15 points), University of California at Los Angeles activity scores (6.5 vs 6.8 points), the incidence of thigh pain (0% vs 4%), revision rates (0% vs 4%), aseptic loosening rate (0% vs 2%), and complication rates (2% vs 4%) were not significantly different between 2 groups.Conclusion
Both ultra-short anatomic and ultra-short non-anatomic proximal loading uncemented femoral stems obtained rigid fixation without diaphyseal stem fixation in the short-term follow-up. This finding suggests that an ultra-short anatomic uncemented femoral stem can be replaced with an ultra-short non-anatomic uncemented stem to reduce inventory of the femoral stems, and consequently reduce manufacturing and delivery cost of these femoral stems. 相似文献10.
Sureshan Sivananthan Chin-Tat Lim Rapeepat Narkbunnam Alex Sox-Harris James I. Huddleston Stuart B. Goodman 《The Journal of arthroplasty》2017,32(4):1245-1249
Background
Modular femoral stem provides flexibility in femoral reconstruction, ensuring improved “fit and fill”. However, there are risks of junction failure and corrosion, as well as cost concerns in the use of modular femoral stems.Methods
We reviewed prospectively-gathered clinical and radiographic data on revision total hip arthroplasties (THAs) performed from 2001-2007 using modular, cementless femoral component performed by the 2 senior authors. Patients with a minimum follow-up of 7 years were included in this study.Results
Sixty-four patients (68 hips) with a median age of 68 ± 14 years (range 40-92 years) at revision THA were included. The median follow-up was 11.0 ± 1.8 years (range 7-14). Harris hip score, femoral stem subsidence, and stem osseointegration were recorded. The Harris hip score improved from an average of 38.1-80.1 (P < .01). Five hips had one or more dislocations. Seven patients underwent reoperations, 3 of which did not involve the stem. Four stems required revision because of infection, recurrent dislocation, or suboptimal implant position. Survival rates for any reasons and revision for femoral stems were 90% and 94%, respectively, at the most recent follow-up. Four stems subsided more than 5 mm, but established stable osseointegration thereafter. Seven nonloose stems (10.2%) demonstrated radiolucent lines in Gruen zones 1 and 7. No complications regarding the modular junction were encountered.Conclusion
Modular, cementless, extensively porous-coated femoral components have demonstrated intermediate-term clinical and radiographic success. Initial distal intramedullary fixation ensures stability, and proximal modularity further maximizes fit and fill. 相似文献11.
Nienke M. Kosse Gijs G. van Hellemondt Ate B. Wymenga Petra J.C. Heesterbeek 《The Journal of arthroplasty》2017,32(1):197-201
Background
Short-term stability after revision total knee arthroplasty (TKA) with either fully cemented or hybrid-placed implants is comparable. Interestingly, implant micromotion >1 mm/degree occurred with both techniques which might increase the risk of loosening in the midterm or long-term. Therefore, the present study investigated midterm stability and clinical results of fully cemented vs hybrid-placed revision TKA, with mild to moderate bone loss, using radiostereometric analysis (RSA).Methods
This study involves the prolonged follow-up of a previous randomized controlled trial. RSA images taken at baseline, 6 weeks, 3 and 6 months, and 1, 2 and 6.5 years of follow-up were analyzed. Stability of the femoral and tibial implants was evaluated using total translation and rotation, based on the micromotion determined with model-based RSA.Results
Of the 30 patients who completed the 2-year follow-up in the original randomized controlled trial, 23 (12 cement, 11 hybrid) were available for follow-up at 6.5-year (range 5.4-7.3). There were no differences in median total translation and rotation of the femoral and tibial components between the 2 groups, and none of the clinical scores differed between the groups. Interestingly, in the group with cemented stems, 5 tibia implants showed >1 mm/degree micromotion compared to none in the hybrid group.Conclusion
There was no difference in median micromotion and clinical outcome between fully cemented and hybrid-placed revision TKA 6.5 years postoperatively. Two femur components showed progressive migration over time whereas tibia components migrate especially in the first year followed by a stable situation. Whether this will lead to loosening and re-revisions remains to be investigated. 相似文献12.
K. Keely Boyle Scott R. Nodzo Joseph T. Ferraro David J. Augenblick Sonja Pavlesen Matthew J. Phillips 《The Journal of arthroplasty》2018,33(4):1082-1088
Background
Aseptic loosening of cemented and uncemented tibial components continues to be a source of implant failure after total knee arthroplasty (TKA) in the obese population. There is limited literature reviewing uncemented cruciate retaining (CR) components in the obese population.Methods
A clinical and radiographic review was performed on 325 patients who underwent a cemented or uncemented TKA with a CR knee prosthesis and body mass index ≥30 kg/m2 between January 2010 and June 2013. Charts were reviewed for the incidence of revision due to aseptic loosening of the tibial baseplate, revision for any reason, incidence of radiolucent lines around the tibial baseplate, range of motion, and patient reported outcomes.Results
There was no statistically significant difference between groups in survivorship for aseptic loosening of the tibial component (99.4% uncemented, 99.3% cemented, P = .94) and overall survivorship (98.1% uncemented, 98.3% cemented, P = .90). The Lower Extremity Activity Scale and Forgotten Joint Score-12 clinical outcome measures were similar between groups (10.2 ± 3.7 vs 9.7 ± 3.4 and 66.1 ± 28.2 vs 64.9 ± 24.3, P = .33, P = .78, respectively). Postoperative knee flexion was similar between groups (114.6 ± 9.3 vs 114.1 ± 9.3, P = .67).Conclusion
Our study demonstrated similar survivorship of this CR design for aseptic loosening of the tibial baseplate and overall revision rates in obese patients undergoing either an uncemented or cemented TKA. The uncemented and cemented groups had comparable clinical and radiographic short to mid-term outcomes when implanted in good alignment when treating end-stage knee osteoarthritis. 相似文献13.
《The Journal of arthroplasty》2022,37(1):110-118
BackgroundData assessing femoral stems may be influenced by grouping together matt and polished stems, despite their differing reported survivorship. The aim of this study is to assess the difference in revision rates between commonly used cemented and cementless stems when polished tapered stems are assessed independently of matt stems.MethodsAustralian Orthopaedic Association National Joint Replacement Registry data from 1999 to 2019 were used to assess difference in revision rates between the 5 most commonly implanted femoral cemented and cementless stems for osteoarthritis. Cemented matt femoral stems, stems using line-to-line cementing techniques and procedures using non-cross-linked polyethylene, large head (>32 mm) metal-on-metal bearing surfaces or exchangeable necks were excluded. Cumulative percent revision was used to help compare survivorship between stems.ResultsThere were 201,889 total hip replacements meeting the inclusion criteria, of which 50.0% were cemented and 50.0% cementless. Cemented stems had a lower rate of revision at all time points compared to cementless stems. This was most significant during the first 2 weeks (hazard ratio 0.48, 95% confidence interval 0.40-0.58, P < .001) compared to 2 weeks postoperatively and onwards (hazard ratio 0.85, 95% confidence interval 0.81-0.90, P < .001). A subanalysis of head size, bearing type, and surgeon volume further supported the use of a cemented stem.ConclusionCommonly used cemented polished tapered stems have a lower revision rate when compared to commonly used cementless prostheses, and are recommended in all age groups for both low-volume and high-volume surgeons especially when head size 32 mm or smaller is used. 相似文献
14.
Ahmed Nageeb Mahmoud Martin Sundberg Gunnar Flivik 《The Journal of arthroplasty》2017,32(5):1612-1617
Background
Porous metal augments have been used successfully for management of large acetabular defects during revision hip arthroplasty. The purpose of this study was to retrospectively review and compare the clinical and radiographic outcomes of porous metal augments in cemented and uncemented acetabular revisions, all performed at the same institution.Methods
Using our institutional clinical databases, the clinical and radiological outcomes of 104 cemented and 43 uncemented acetabular revisions with metal augments, performed between 2006 and 2015, were studied and compared. Acetabular augments were used when preoperative and intraoperative findings indicated the presence of large acetabular defects that can hinder the stability of the revision implants.Results
At a mean follow-up of 60.1 months (range 12.7-112.1), a total of 5 cups (3.4%), being 3 cemented (2.8%) and 2 uncemented (4.6%), had shown signs of aseptic loosening with cup and augment migration and 4 of these have been re-revised (2.7%). At final follow-up, the European Quality of Life-5 Dimensions for generic health, and the Hip disability and Osteoarthritis Outcome Score (HOOS) parameters had improved substantially without any significant difference between fixation techniques.Conclusion
Porous metal augments show comparable excellent radiographic and clinical mid-term outcomes when combined with cemented or uncemented cups in revision hip arthroplasty. 相似文献15.
Jonathan Hutt Alexandra Hazlerigg Ansari Aneel Geoffrey Epie Husam Dabis Roy Twyman Andrew Cobb 《International orthopaedics》2014,38(6):1131-1137
Purpose
The optimal design for a cemented femoral stem remains a matter of debate. Over time, the shape, surface finish and collar have all been modified in various ways. A clear consensus has not yet emerged regarding the relative merits of even the most basic design features of the stem. We undertook a prospective randomised trial comparing surface finish and the effect of a collar on cemented femoral component subsidence, survivorship and clinical function.Methods
One hundred and sixty three primary total hip replacement patients were recruited prospectively and randomised to one of four groups to receive a cemented femoral stem with either a matt or polished finish, and with or without a collar.Results
At two years, although there was a trend for increased subsidence in the matt collarless group, this was not statistically significant (p = 0.18). At a mean of 10.1 years follow-up, WOMAC scores for the surviving implants were good, (Range of means 89–93) without significant differences. Using revision or radiographic loosening as the endpoint, survivorship of the entire cohort was 93 % at 11 yrs, (CI 87–97 %). There were no significant differences in survivorship between the two groups with polished stems or the two groups with matt stems. A comparison of the two collarless stems demonstrated a statistically significant difference in survivorship between polished (100 %) and matt (88 %) finishes (p = 0.02).Conclusions
In the presence of a collar, surface finish did not significantly affect survivorship or function. Between the two collarless groups a polished surface conferred an improved survivorship. 相似文献16.
Ahmed Fadulelmola Efstathios Drampalos John Hodgkinson Mukesh Hemmady 《The Journal of arthroplasty》2017,32(6):1970-1975
Background
Acetabular impaction bone grafting aims to restore anatomy in hip revision surgery. This is an effective but expensive and time-consuming technique. Usually, the articular cartilage is removed from the femoral head allograft. We aimed to reproduce the same results retaining the cartilage of the allograft.Methods
Eighty acetabular revisions using impacted morselized bone graft retaining the articular cartilage and a cemented cup were studied retrospectively. Six were lost during follow-up. The mean follow-up was 6.5 years (range 1-13). Clinical and radiological assessment was made using the Oxford Hip Score, Hodgkinson's criteria for socket loosening, and the Gie classification for evaluation of allograft incorporation.Results
Sixty-three sockets (85.1%) were considered radiologically stable (type 0, 1, and 2 demarcations), 8 (10.8%) were radiologically loose (type 3), and 3 (4.1%) presented with migration. Fifty-one (68.9%) cases showed good trabecular remodeling (grade 3), 20 (27%) showed trabecular incorporation (grade 2), and 3 (4.1%) showed poor allograft incorporation. Mean preoperative hip score was 43 and postoperative score was 28. Six (8.1%) cases presented heterotopic ossification around the revised implants, 2 patients (2.7%) had periprosthetic fractures, and 4 (5.4%) had dislocations. The Kaplan-Meier survivorship at a mean of 6.5 years with revision of the cup for any reason was 95.9% (95% confidence interval 5.6-7.5).Conclusion
The mid-term results of our technique are promising. Particularly when the supply of fresh-frozen allografts and surgical time is limited, using whole femoral head with articular cartilage is both safe and effective. 相似文献17.
Brian P. Chalmers Kevin I. Perry Arlen D. Hanssen Mark W. Pagnano Matthew P. Abdel 《The Journal of arthroplasty》2017,32(10):3071-3075
Background
Conversion of hemiarthroplasty to total hip arthroplasty (THA) has a historically high, up to 20%, postoperative dislocation rate. As such, dual-mobility (DM) constructs are an attractive option to mitigate this complication. We analyzed survivorship free of revision, complications, and clinical outcomes of hemiarthroplasties conversion to THAs utilizing DM constructs compared with large femoral heads (≥36 mm).Methods
Conversion of 16 hemiarthroplasties to THAs with a specific DM construct compared with 13 conversions utilizing large femoral heads (≥36 mm) from 2011 to 2014 were reviewed. Mean age at conversion in the DM group was 75 years (range, 57-93 years); 75% were female. Significantly more patients with a dislocated hemiarthroplasty were converted to DM constructs compared to large femoral heads (44% vs 0%; P = .01). Mean follow-up was 3 years.Results
Survivorship free of revision was 100% in the DM group compared with 92% in the large femoral head cohort at 2 years (P = .7). One (8%) patient converted to a large femoral head underwent revision to a constrained liner for recurrent dislocations while no patients experienced a postoperative dislocation in the DM group (P = .4). Harris Hip Scores improved from 54 to 82 (P < .01) in the DM group, and from 52 to 86 in the large femoral head group (P < .01).Conclusion
Larger effective femoral heads used during conversion of hemiarthroplasties to THAs resulted in high survivorship free of revision, minimal complications, and excellent clinical outcomes at short-term follow-up. In patients at highest risk for postoperative dislocation, including those with dislocating hemiarthroplasties, DM constructs resulted in no postoperative dislocations. 相似文献18.
Brian P. Chalmers Nicholas M. Desy Mark W. Pagnano Robert T. Trousdale Michael J. Taunton 《The Journal of arthroplasty》2017,32(5):1565-1570
Background
Metaphyseal fixation has promising early results in providing component stability and fixation in revision total knee arthroplasty (TKA). However, there are limited studies on midterm results of metaphyseal sleeves. We analyzed complications, rerevisions, and survivorship free of revision for aseptic loosening of metaphyseal sleeves in revision TKA.Methods
Two hundred eighty patients with 393 metaphyseal sleeves (144 femoral, 249 tibial) implanted during revision TKA from 2006-2014 were reviewed. Sleeves were most commonly cemented (55% femoral, 72% tibial). Mean follow-up was 3 years, mean age was 66 years, and mean body mass index was 34 kg/m2. Indications for revision TKA included 2-stage reimplantation for deep infection (37%), aseptic loosening of the tibia (14%), femur (12%), or both components (9%), and instability (14%).Results
There was a 12% rate of perioperative complications, most commonly intraoperative fracture (6.5%). Eight sleeves (2.5%) required removal: 6 (2%) during component resection for deep infection (all were well-fixed at removal) as well as 1 (0.8%) femoral sleeve and 1 (0.8%) tibial sleeve for aseptic loosening. Five-year survivorship free of revision for aseptic loosening was 96% and 99.5% for femoral and tibial sleeves, respectively. Level of constraint, bone loss, sleeve and/or stem fixation, and revision indication did not significantly affect outcomes.Conclusion
Metaphyseal sleeve fixation to enhance component stability during revision TKA has a 5-year survivorship free of revision for aseptic loosening of 96% and 99.5% in femoral and tibial sleeves, respectively. Both cemented and cementless sleeve fixation provides reliable durability at intermediate follow-up. 相似文献19.
James W. Pritchett 《The Journal of arthroplasty》2018,33(11):3508-3513
Background
Hip dysplasia is the leading cause of hip arthritis in young adults. These patients often participate in active lifestyles that require a full and stable range of motion.Methods
Between 2001 and 2011, 232 consecutive polyethylene resurfacing arthroplasties were performed in 201 patients with advanced arthritis from severe acetabular insufficiency due to dysplasia. All patients had Crowe II or III disease. Their mean age at surgery was 43 years. A 2-piece cementless acetabular resurfacing shell with dome screws and a highly cross-linked polyethylene liner were implanted to provide secure fixation, early weight bearing, and a stable hip. Additional structural bone grafts and/or fixation were not used. A cemented or cementless resurfacing prosthesis was used on the femur.Results
During a mean follow-up of 10 years, 8 hips (3.5%) were converted to a total hip arthroplasty due to acetabular loosening (1), femoral neck fracture (2), femoral osteonecrosis (2), infection (2), or persistent pain (1), resulting in a mean survival of the resurfacing prostheses of 96% (95% confidence interval 89-98). There were no pending revisions and no dislocations. At 2 years postoperative, Harris Hip Scores improved from a preoperative mean of 55 to 97 and University of California Los Angeles activity scores improved from 5 to 8.Conclusion
Hip resurfacing using a 2-piece polyethylene acetabular component for advanced dysplasia has resulted in excellent function and implant survivorship with a low rate of complications at mid-term follow-up. 相似文献20.
Tatsuya Tamaki Kurato Jonishi Yoko Miura Kazuhiro Oinuma Hideaki Shiratsuchi 《The Journal of arthroplasty》2018,33(3):805-809