The clinical status of 83 Mittelmeier ceramic—ceramic (Mark II) cementless total hip prostheses (Autophor, Osteo AG, Selzach, Switzerland) implanted between 1978 and 1984 was analyzed. Retrieved tissue from the revised hips was studied histologically. The mean patient age was 47.5 years (range, 19–71 years). One or both components of 12 hips were revised (16% at 16 years in the survival study). Eleven acetabular components and seven stems were revised, with three of the sockets fractured. The mean follow-up period for the patients with unrevised hips was 12.3 years. Osseointegration was uncommon in both the cup and stem. Radiographic cup loosening was observed in 53% of hips at 16 years in the survival study, with most having a complete radiolucent line of 2 mm around the cup. Radiographic stem loosening appeared in 15% of hips at 16 years. Fibrous stable fixation was present in 64% of stems. Significant radiographic acetabular wear was not observed in any hip. The Mittelmeier Mark II prosthesis had worse long-term results than reported with cemented or other uncemented prostheses. Although there was no significant acetabular wear, intracellular ceramic wear debris was seen in the retrieved tissues.  相似文献   

2.
We evaluated 34 total hip arthroplasties (THA) for avascular necrosis of the femoral head in 26 patients who were younger than 40 years at the time of the index operation. The average age at the time of THA was 283 (17-38) years. The mean follow-up was 10.9 (5-19) years. We used 6 cemented and 28 cementless acetabular components and a cemented polished tapered stem in all hips. The mean Charnley modified Merle d' Aubigné Postel score was 8.9 points preoperatively and 16.6 points at final follow-up. Two cemented metal-backed cups were revised because of aseptic loosening at 10 years, one cemented polyethylene cup failed at 12 years and 2 more all polyethylene cups had pending failure. The metal-backed cemented cups and the all polyethylene cups had a longer follow-up than the uncemented cups. Therefore and because of the proven unfavourable long-term outcome of the cemented metal-backed Exeter cup we are not able to draw any firm conclusions regarding the preferred choice between cemented and uncemented cups in this particular group of patients. On the femoral site none of the stems had to be revised. Our results show that a cemented polished tapered femoral component has an excellent survival in primary total hip replacement in young patients with avascular necrosis of the femoral head.  相似文献   

3.
BackgroundThe efficacy of contemporary monoblock dual-mobility (DM) cups to prevent dislocations in total hip arthroplasty (THA) is well reported, but there is little published data on their mid- to long-term outcomes. The authors aimed at reporting the 10-year survival of a contemporary DM cup as well as its clinical and radiographic outcomes.MethodsFrom a retrospective consecutive multicentric series of 516 patients (541 hips) that received uncemented THA between June 2007 and June 2010, 6 patients (6 hips) had cup and stem revisions, 5 patients (5 hips) had isolated stem revision, and 2 patients (2 hips) had isolated insert revision. A total of 103 patients (111 hips) died with their original implants, and 41 patients (42 hips) were lost to follow-up. This left 358 patients (375 hips) for clinical assessment at a median follow-up of 8.7 years (range, 6.8-10.5 years), including 279 patients (290 hips) with postoperative radiographs. Implant survival was calculated using the Kaplan-Meier method, and multivariable analyses were performed to determine whether clinical outcomes are associated with patient or surgical factors.ResultsThe 10-year survival considering revision for aseptic loosening as end point was 100% for the cup and 99.2% for the stem. No dislocations were observed, and radiographic assessment revealed 1 acetabular granuloma (0.3%), but no radiolucencies nor fractures. The Harris hip score improved from 49.6 ± 15.5 to 85.2 ± 14.5, and the postoperative Oxford hip score was 19.2 ± 7.6. Multivariable analyses revealed that improvement in Harris hip score increased with cup diameter (beta, 1.28; P = .039).ConclusionOur data confirmed satisfactory midterm outcomes of uncemented THA using a contemporary DM cup, with no dislocations nor cup revisions due to aseptic loosening.Level of EvidenceLevel IV, retrospective cohort study.  相似文献   

4.
Two-hundred fifty implantations of a cemented femoral stem made of titanium alloy in 239 patients were followed for 9.7 years (range 8.7-10.3 years). Eighty-nine patients with 93 hips have died and two could not be located. Five hips have been revised, two for infection, one for aseptic loosening and two during revision of the cup. Three stems showed radiological loosening but have not been revised. The average hip score was 85. The results are encouraging and comparable to other cemented femoral stems.  相似文献   

5.
Outcome of the acetabular component in 90 consecutive primary noncemented total hip arthroplasties (THAs) was prospectively studied. The acetabular cup consisted of a hemispherical titanium alloy shell with a titanium fiber-mesh porous coating and a modular polyethylene liner (Harris-Galante Porous-1, Zimmer, Warsaw, Ind). The cup was implanted using line-to-line reaming with adjunctive dome screw fixation. The femoral component consisted of a titanium alloy stem with titanium fiber-mesh porous coating and a 28-mm cobalt-chrome modular head. Mean patient age was 53 years (range: 27-75 years); male:female ratio was 48:42; and mean follow-up was 6 years (range: 4.5-8 years). One acetabular component was revised for aseptic loosening. Of 81 unrevised hips available for follow-up, mean Harris hip score was 57 preoperatively and 96 at final follow-up (72% excellent, 15% good, 1 3% fair, and none poor). Of 61 unrevised hips with adequate radiographic follow-up, radiographic failure (complete periprosthetic radiolucency) was evident in 3 (4.9%) and periacetabular osteolysis in none. Radiographic failure did not correlate with poor clinical outcome. Linear polyethylene wear rate (mean: 0.13 mm/year) did not correlate with age, gender, weight, outcome, or cup abduction angle, but did correlate with the presence of femoral periprosthetic osteolysis (0.18 mm/year with femoral osteolysis versus 0.11 mm/year without; P= .01). This series of porous-coated hemispherical cups demonstrated excellent intermediate-term clinical and radiographic outcome, comparable with similarly favorable results reported by the prosthesis designers. A potentially adverse effect of polyethylene wear on the longevity of a THA was supported by a positive correlation between polyethylene wear rate and femoral osteolysis.  相似文献   

6.
INTRODUCTION: We report the results of a titanium acetabular reinforcement ring with a hook (ARRH) in primary total hip arthroplasty (THA), which was introduced in 1987 and continues to be used routinely in our center. The favorable results of this device in arthroplasty for developmental dysplasia and difficult revisions motivated its use in primary THA. With this implant only minimal acetabular reaming is necessary, anatomic positioning is achieved by placing the hook around the teardrop and a homogenous base for cementing the polyethylene cup is provided. MATERIALS AND METHODS: Between April 1987 and December 1991, 241 THAs with insertion of an ARRH were performed in 178 unselected, consecutive patients (average age 58 years; range 30-84 years) with a secondary osteoarthrosis in 41% of the cases. RESULTS: At the time of the latest follow-up, 33 patients (39 hips) had died and 17 cases had been lost to follow-up. The median follow-up was 122 months with a minimum of 10 years. Eight hips had been revised, leaving 177 hips in 120 living patients without revision. Six cups were revised because of aseptic loosening. Two hips were revised for sepsis. The mean Merle d'Aubigné score for the remaining hips was 16 (range 7-18) at the latest follow-up. For aseptic loosening, the probability of survival of the cup was 0.97 (95% confidence interval, 0.94-0.99). However, analysis of radiographs implied loosening in seven other cups without clinical symptoms. CONCLUSIONS: The results of primary THA using an acetabular reinforcement ring parallel the excellent results of these implants often observed in difficult primary and revision arthroplasty at a minimum of 10 years. Survivorship is comparable to modern cementless implants. Medial migration that occurs with loosening of the acetabular component seems to be prevented with this implant. Radiographic loosening signs can exist without clinical symptoms.  相似文献   

7.
Background Aseptic loosening is the major cause of implant failure. In cemented hip arthroplasty, failure of the acetabular side is mainly due to lysis caused by wear particles. By using an implant with low wear characteristics and by enhancing acetabular fixation using an uncemented implant, we aimed to reduce acetabular lysis and thereby loosening.

Patients and methods This was a retrospective cohort study of 119 hips (101 patients) that had the Uncemented Fitmore cup (Sulzer Orthopedics). In 66 patients, the femoral component was CF-30 (Sulzer) used with cement. In the remaining 35 patients, thrust plate prosthesis (TPP) (Sulzer) was used. Of the 101 patients, 94 (112 hips) were available for study. Mean follow-up of the 94 patients was 7 (5-13) years.

Results The mean preoperative Harris hip score was 38 and the mean postoperative Harris hip score was 89 at the last follow-up. Taking aseptic loosening as the endpoint, the survival rate of the Fitmore cup was 100% at 11 years.

Interpretation The uncemented Fitmore acetabular cup with second generation metal-on-metal articulation showed good results with regard to aseptic loosening in the medium term.  相似文献   

8.
A higher-than-average rate of aseptic loosening has been postulated to be associated with the combination of a titanium stem and bone cement. In this prospective follow-up study we therefore investigated our first consecutive series of 250 implantations of a cemented femoral shaft prosthesis made of titanium alloy (BiCONTACT((R)), Aesculap, Tuttlingen, Germany).Average time of follow-up evaluation was 9.7 years (range 8.7-10.3 years). At follow-up, mean patient age was 81 years; 89 patients with 93 hips have deceased and two could not be located. Follow-up rate was 98.7% for the patients still alive at time of follow-up evaluation. Five patients have been revised, two for infection and one for aseptic loosening of a varus-malaligned stem; two radiologically well-fixed stems had been revised during acetabular revision. Survival estimate showed a calculated cumulative survival rate of 97.5% after 11 years [confidence limits: 99.0% (upper) and 94.1% (lower)]. The average Harris hip score at time of follow-up was 82.25 points.Radiologically, signs of loosening could be detected in 3 stems: in one case varus malalignement deteriorated with time and in 2 cases osteolyses developed together with significant polyethylene wear. All 3 patients experienced only mild pain and revision had not been indicated so far. In conclusion, the long-term follow-up results with this cemented titanium femoral component are encouraging and are comparable to other successful cemented femoral components in primary total hip arthroplasty. No increased risk for aseptical loosening was associated to the combination of titanium and cement in this specific stem. Design parameters seem to play an important role in the development of aseptic loosening in cemented titanium stems.  相似文献   

9.
BACKGROUND: Extra-large uncemented components provide several advantages for acetabular revision, but limited information is available on the results of their use. The purpose of this study was to evaluate, at a minimum of five years, the results associated with the use of an extra-large uncemented porous-coated component for acetabular revision in the presence of bone loss. METHODS: Eighty-nine extra-large uncemented hemispherical acetabular components were used for revision after aseptic failure of a total hip arthroplasty in forty-six men and forty-three women (mean age at revision, fifty-nine years; range, thirty to eighty-three years). The revision implant (a Harris-Galante-I or II cup fixed with screws) had an outside diameter of > or = 66 mm in men and > or = 62 mm in women. Seventy-nine patients had a segmental or combined segmental and cavitary acetabular bone deficiency before the revision. Particulate bone graft was used in fifty-four hips and bulk bone graft, in nine. RESULTS: One patient died with the acetabular component intact and two patients were lost to follow-up within five years after the operation. At the time of the last follow--up, four acetabular components had been removed or revised again (two for aseptic loosening). All of the remaining patients were followed clinically for at least five years (mean, 7.2 years; range, 5.0 to 11.3 years). In the hips that were not revised again, only two sockets had definite radiographic evidence of loosening. All four of the sockets that loosened were in hips that had had combined cavitary and segmental bone loss preoperatively. In the hips that were not revised again, the mean modified Harris hip score increased from 56 points preoperatively to 83 points at the time of the most recent follow-up. The most frequent complication, dislocation of the hip, occurred in eleven patients. The probability of survival of the acetabular component at eight years was 93% (95% confidence interval, 85% to 100%) with removal for any reason as the end point, 98% (95% confidence interval, 92% to 100%) with revision for aseptic loosening as the end point, and 95% (95% confidence interval, 88% to 100%) with radiographic evidence of loosening or revision for aseptic loosening as the end point. CONCLUSIONS: This study demonstrates that extra-large uncemented components used for acetabular revision in the presence of bone loss perform very well and have a low rate of aseptic loosening at the time of intermediate-term follow-up.  相似文献   

10.
BACKGROUND: Anterolateral acetabular bone deficiency is one of the technical problems associated with total hip arthroplasty in patients with developmental hip dysplasia. The purpose of this study was to evaluate the results of one method of acetabular reconstruction for hip dysplasia-placement of an uncemented socket in conjunction with a bulk femoral head autograft. METHODS: Forty-four hips in thirty-five patients (twenty-nine female and six male; average age, thirty-nine years) with developmental hip dysplasia were treated with primary total hip arthroplasty with use of an uncemented porous-coated titanium cup fixed with screws and an autogenous bulk femoral head graft. The patients were followed clinically in a prospective fashion for five to 12.3 years (mean, 7.5 years), and radiographs were analyzed retrospectively. RESULTS: Four acetabular components were revised: two, because of severe polyethylene wear and osteolysis; one, because of aseptic loosening; and one, because of fracture of the acetabular shell. The mean Harris hip score for the unrevised hips improved from 51 points preoperatively to 91 points postoperatively. No unrevised socket had definite radiographic evidence of loosening. Forty-three of the forty-four hips had no radiographic evidence of resorption of the graft or had radiographic evidence of resorption limited to the nonstressed area of the graft lateral to the edge of the cup. CONCLUSIONS: This method of reconstruction provided reliable acetabular fixation and appeared to restore acetabular bone stock in patients with developmental hip dysplasia. We use this technique for patients with moderate anterolateral acetabular bone deficiency requiring total hip arthroplasty.  相似文献   

11.
To analyze long-term survivorship of cementless total hip arthroplasties (THAs) with the third-generation alumina ceramic-on-ceramic bearing, 100 consecutive THAs between 1996 and 1998 were reviewed. One cup and 2 stems were revised due to aseptic loosening. Another cup showed chipping of the acetabular liner at 8 years and required cup revision. The remaining hips showed stable bone ingrowth fixation with no osteolysis at the final follow-up. The 14-year survivorship as the end point of revision was 97.9% for the cup, 97.8% for the stem, and 95.7% for the overall implants, respectively. We conclude that cementless THA with the third-generation ceramic-on-ceramic hip bearing provided an excellent survivorship and eliminated periprosthetic osteolysis for 11 to 14 years.  相似文献   

12.
In an attempt to decrease aseptic loosening, total joint components are now being used without cement. Most components are designed to achieve fixation biologically. The radiographic results of 144 primary uncemented total hip arthroplastics and the clinical results of 89 arthroplastics that were performed using a proximally porous-coated titanium alloy femoral stem between November 1983 and June 1989 are reported. On the acetabular side, a threaded component or a hemispherical porous-coated component was used. The patients were followed prospectively for 5 to 9 years postsurgery. During the study period, the threaded acetabular component had a high failure rate. Because it was not possible to determine accurately from which component a particular sign or symptom arose, clinical analysis was restricted to only those hips without a failed or revised cup. Eighty-nine hips in 71 patients with a minimum follow-up period of 5 years were available for clinical review. Radiographic review of the femoral stem was completed on all hips with 5 or more years of radiographic follow-up evaluation, regardless of the status of the acetabular component. One hundred twelve hips in 85 patients were analyzed radiographically. At a latest mean follow-up period of 6.7 years, the mean Iowa hip score was 91.4 ± 8.0 with a 5.4% incidence of thigh pain. Throughout the followup period, the patients with thigh pain had a statistically lower mean Iowa pain subscore when compared with those patients without thigh pain (P = .0001). Endosteal erosion was seen in two hips (1.8%) and longitudinal loss of the medial neck greater than 2 mm was noted in two hips. One femoral stem was revised for aseptic loosening. The clinical results of this femoral stem equal ot exceed the published accounts of other uncemented arthroplasties. The results indicate that the stem is associated with good clinical results, minimal bone loss, and little osteolysis. Continued follow-up evaluation of patients with this femoral stem is necessary to assess the durability of these encouraging results.  相似文献   

13.
Uncemented, threaded acetabular components with smooth surface treatment were widely used in continental Europe in the 1970s and 1980s for primary total hip arthroplasty (THA). Previously published studies showed high failure rates in the mid-term. In a consecutive series of 116 patients, 127 threaded cups with smooth surface treatment (Weill cup; Zimmer, Winterthur, Switzerland) were implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. Mean time of follow-up was 17 years (range 15–20). At the time of follow-up, the acetabular component had been revised or was awaiting revision in 30 hips (24%). Two hips were revised for infection and 23 for aseptic loosening. Four polyethylene liners were exchanged because of excessive wear. One hip was awaiting revision. The survival rate for all acetabular revisions including one hip awaiting revision was 75% (95%CI: 65–85%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. It is important to closely monitor patients with these components as the failure rate remains high in the long-term.  相似文献   

14.
We report on a prospective series of 201 primary uncemented total hip arthroplasties with a Bicontact prosthesis at a mean follow-up of 12.9 years. The mean Harris hip score improved from 41 before surgery to 89 at final follow-up. Two femoral stems, one each for infection and fracture, and 12 cups were revised. The mean number of years to revision post-primary surgery was 8.7 years (six months to 16 years). The cumulative survival of the prosthesis was 95.42% for any cause at ten years and 93.57% at 12 years. Survivorship for aseptic loosening of the femoral stem was 100%. In our series, the Bicontact uncemented total hip arthroplasty stem without hydroxyapatite coating showed excellent survival and the cup survival was comparable to other leading series.  相似文献   

15.
We report a long-term review of 41 acetabular reconstructions using impacted morsellized bone grafts and a cemented total hip arthroplasty (THA) in patients younger than 50 (22-49; average 38) years. Reconstruction was performed in 23 primary THA (19 patients) and 18 revision THA (17 patients). 3 patients were lost to follow-up and 3 (4 hips) died within 10 years of surgery; none had a revision. Thus, 34 hips (30 patients) were reviewed with an average follow-up of 13 (10-18) years. In 2 hips, a revision was performed for aseptic loosening of the acetabular component 7 and 11 years after surgery. One additional cup was revised after 12 years during a femoral stem revision due to wear and matching problems, but was well fixed. The survival rate of the acetabular reconstruction technique was 94% (95% CI: 90-98%).  相似文献   

16.
Introduction In the 1970s and 1980s, uncemented, threaded acetabular components with smooth surface treatment were widely used in continental Europe for arthroplasty of the hip to overcome the high rate of aseptic loosening in cemented hip arthroplasty in young patients. There were several reports on short- and intermediate-term results, but information on survival in the longer term is not available at present.Materials and methods In a consecutive series of 320 patients, 348 threaded cups with smooth surface treatment (221 Mecring and 127 Weill) had been implanted in combination with one type of uncemented stem. Patients were followed clinically and radiographically. The mean time of follow-up was 12.4 (range 10–15) years (Mecring 11.9 years, Weill 13.3 years).Results In 76 hips the acetabular component had been revised (Mecring 56, Weill 20): 7 hips for infection and 69 for aseptic loosening. Of the remainder, the cup had migrated in 55 hips, and 32 hips were awaiting revision. Survival at 14 years was 63.8% (95%CI: 52.5–75.0%) for the Mecring and 76.2% (95%CI: 65.6–86.7%) for the Weill component. Radiolucent lines were present in 59 hips (31.9%). The median Harris Hip Score at follow-up was 84 points (Mecring 85, Weill 82). Radiographic loosening did not correlate with clinical outcome.Conclusion These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned.  相似文献   

17.
We report a long-term review of 41 acetabular reconstructions using impacted morsellized bone grafts and a cemented total hip arthroplasty (THA) in patients younger than 50 (22-49; average 38) years. Reconstruction was performed in 23 primary THA (19 patients) and 18 revision THA (17 patients). 3 patients were lost to follow-up and 3 (4 hips) died within 10 years of surgery; none had a revision. Thus, 34 hips (30 patients) were reviewed with an average follow-up of 13 (10-18) years. In 2 hips, a revision was performed for aseptic loosening of the acetabular component 7 and 11 years after surgery. One additional cup was revised after 12 years during a femoral stem revision due to wear and matching problems, but was well fixed. The survival rate of the acetabular reconstruction technique was 94% (95% CI: 90-98%).  相似文献   

18.
《The Journal of arthroplasty》2020,35(4):1042-1047
BackgroundThere is variable evidence regarding survivorship beyond 20 years of total hip arthroplasties in young patients. We report the long-term results of the Exeter cemented hip system in patients ≤50 years at minimum of 20 years.MethodsClinical and radiological outcomes of 130 consecutive total hip arthroplasties in 107 patients aged 50 years or younger at primary operation were reviewed; 77% had a diagnosis other than osteoarthritis. All patients were followed at 5-year intervals, no patients were lost to follow-up, and the status of every implant is known.ResultsMean age at surgery was 41.8 (17-50) years. Mean follow-up was 22.0 (20.0-26.1) years. There were 79 hips surviving, 14 hips (11 patients) deceased, and 37 hips revised. Reasons for revision: 29 hips for aseptic cup loosening (26 stems revised using cement-in-cement, three left in-situ); three stems for femoral osteolysis, two related to acetabular polyethylene wear (14.1 and 17.0 years), one with Gaucher’s disease (21.1 years); one broken stem (12.9 years); one cup for instability (4.3 years–stem revised using cement-in-cement); and two hips with infection (8.5 and 23.8 years). There were no cases of aseptic loosening of the Exeter stem. There were no radiologically loose stems although eight patients had radiological evidence of loosening of the cemented cup. Survivorship at 22 years was 74.9% for revision for all causes and 96.3% for revision of the stem for aseptic loosening or lysis.ConclusionThe Exeter cemented stem has excellent survivorship at minimum 20 years in young patients. Acetabular component survivorship was less favorable, but the advent of highly cross-linked polyethylene may improve this in the long term.  相似文献   

19.
AIM: To present the 18 year survival and the clinical and radiological outcomes of the Müller straight stem, cemented, total hip arthroplasty (THA).METHODS: Between 1989 and 2007, 176 primary total hip arthroplasties in 164 consecutive patients were performed in our institution by the senior author. All patients received a Müller cemented straight stem and a cemented polyethylene liner. The mean age of the patients was 62 years (45-78). The diagnosis was primary osteoarthritis in 151 hips, dysplasia of the hip in 12 and subcapital fracture of the femur in 13. Following discharge, serial follow-up consisted of clinical evaluation based on the Harris Hip Score and radiological assessment. The survival of the prosthesis using revision for any reason as an end-point was calculated by Kaplan-Meier analysis.RESULTS: Twenty-four (15%) patients died during the follow-up study, 6 (4%) patients were lost, while the remaining 134 patients (141 hips) were followed-up for a mean of 10 years (3-18 years). HSS score at the latest follow-up revealed that 84 hips (59.5%) had excellent results, 30 (22.2%) good, 11 (7.8%) fair and 9 (6.3%) poor. There were 3 acetabular revisions due to aseptic loosening. Six (4.2%) stems were diagnosed as having radiographic definitive loosening; however, only 1 was revised. 30% of the surviving stems showed no radiological changes of radiolucency, while 70% showed some changes. Survival of the prosthesis for any reason was 96% at 10 years and 81% at 18 years.CONCLUSION: The 18 year survival of the Müller straight stem, cemented THA is comparable to those of other successful cemented systems.  相似文献   