首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Aim

Evaluate the role of ADC value measurements in the differentiation between benign and malignant neck masses.

Methods

From April 2011 to February 2013, prospective study was conducted on 30 patients (17 male and 13 female), with the mean age 43.3 ± 6 years. Collected from wards and clinics of General Surgery and Otolaryngology Departments complaining from neck masses. MRI, Diffusion-Weighted Imaging (b value 0, 100, 500 and 1000 s/mm) and ADC value calculation were performed and the results were correlated with histopathological results and/or follow up.

Results

The present study include 30 patients (Lymphadenopathy {(n = 15) (11 as single entity), (4 associated with other entities)}, Focal thyroid swelling (n = 5), Salivary gland masses (n = 3) {Parotitis (1 case), Parotid carcinoma (2 cases)}, Nasopharyngeal masses (n = 5), Oropharyngeal masses (n = 2), Ludwig angina (n = 2) and Laryngeal masses (n = 2).The mean ADC of the malignant neck masses was (0.699 + 0.267 × 10-3 mm2/s) while that of the benign masses was (1.879 + 0.751 × 10-3 mm2/s).The results confirmed by biopsy in 23 cases and follow up (7 cases).The sensitivity, specificity, PPV, NPV and overall accuracy of quantitative diffusion WI in differentiating benign from malignant neck masses were 95.4%, 83.3%, 95.4%, 83%, and 92%.

Conclusion

ADC value calculation are promising noninvasive imaging approach that can be used in distinguishing between benign and malignant neck masses. Benign lesions have higher mean ADC values than malignant lesions, the cutoff value was 1.25 × 10-3 mm2/s while 0.8 × 10-3 mm2/s in thyroid lesions.  相似文献   

2.

Aim of the work

To detect the diagnostic performance of the combined use of sonoelastographic scoring and strain ratio in differentiation of benign and malignant breast masses with the histopathology is the standard reference.

Patients and methods

One hundred and seventy-two women with 190 breast masses were enrolled in this prospective study. Conventional US (B-mode and color Doppler US) and sonoelastography (elasticity score “ES” and calculation of strain ratio “SR”) were performed. B-mode images were classified according to the Breast Imaging Recording and Data System. The hardness was determined with 5-point scoring method and SRs of the lesions were calculated. Receiver operating characteristic (ROC) curves were performed and the cutoff point for differentiation of benign and malignant masses was detected.

Results

There was a significant difference (P = 0.02) in the mean SRs between benign and malignant breast masses. The area under the curve (AUC) for combination of ES and SR (0.964) was higher than for ES alone (0.852) and B-mode US (0.823). A cutoff value of 3.6 for the SR allowed the best differentiation of benign and malignant breast lesions.

Conclusion

The combined use of elasticity score and strain ratio of sonoelastography increased the diagnostic performance in distinguishing benign from malignant breast masses.  相似文献   

3.

Objectives

To evaluate the additive value of ultrasound strain elastography (USE) to BI-RADS for the differentiation of benign and malignant breast small lesions.

Methods

Breast masses (≤2 cm) with histological diagnosis examined by ultrasonography and USE in our department from April 2004 to December 2009 were reviewed. Conventional B-mode ultrasound findings were classified according to the BI-RADS classification. USE findings were classified according to the 5-point scale. Histological diagnosis was used as the reference standard.

Results

401 (246 benign (61.3%), 155 malignant (38.7%)) from 370 consecutive patients were included in the study. Sensitivity and specificity were 90.3%, 68.3% for BI-RADS; 72.3%, 91.9% for USE. The sensitivity of BI-RADS was better than that of USE (P < 0.05), while the specificity of USE was better than that of BI-RADS (P < 0.05). A revised BI-RADS combined with USE results was proposed in this study. Sensitivity and specificity were 83.9% and 87.8% for revised BI-RADS. The diagnostic performance of revised BI-RADS was better than BI-RADS (P < 0.05).

Conclusions

USE could give BI-RADS some help in the differentiation of benign and malignant breast small lesions. The addition of elastography to BI-RADS could improve the diagnostic performance in <2 cm lesions.  相似文献   

4.

Objective

To assess the diagnostic value of high-frequency (MicroPure) ultrasound in evaluating suspicious microcalcifications and to determine its capability in biopsy guidance.

Subjects and methods

Sixty-two cases with suspicious microcalcifications detected on mammographic examination had been re-evaluated by MicroPure US. The studied cases underwent true cut tissue/surgical excision biopsy. Histopathology revealed 25 benign and 37 malignant lesions and was considered the gold standard of reference.

Results

Malignant microcalcifications were easier to be visible at MicroPure US, as they were detected in 86.5% (n = 32/39) compared to only 68% (n = 17/25) of the benign lesions. US depicted more breast masses associated with malignant microcalcifications in 78% (n = 29/37) than those associated with benign ones seen in 36% (n = 9/25).Visibility of suspicious microcalcifications at US was aided by preliminary mammogram. Given known mammography location of these microcalcifications had made their visualization accessible by MicroPure US in 79% (n = 49) of the cases.

Conclusion

MicroPure ultrasound cannot discriminate benign from malignant breast microcalcifications. MicroPure can be useful in detecting clustered microcalcifications that are not accessible by B-mode ultrasound; provided knowledge of their mammographic location and thus can provide better guidance for pre-surgical wire localization and ultrasound-guided biopsies.  相似文献   

5.

Objective

To evaluate the contribution of power Doppler ultrasonography (PDUS) to breast imaging reporting and data system ultrasonography (BI-RADS US) categorization of solid breast masses.

Materials and methods

Totally 94 solid lesions with histopathological results in 49 patients were included in the study. US features of the lesions were classified according to American College of Radiologists (ACR) BI-RADS US lexicon. Lesions were evaluated qualitatively according to their PDUS properties and quantitatively with spectral analysis. Hypervascularity, penetration of vessels into the mass or branching-disordered course and resistivity index values higher than 0.85 were accepted as probable malignant criteria.

Results

Fifty-five of 94 lesions were benign (58.5%), while 39 (41.5%) were malignant histopathologically. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US and PDUS in the diagnosis of malignant lesions were 100%, 58.2%, 62.9%, 100% and 71.8%, 81.8%, 73.7%, 80.4%, respectively. Criteria used for the distinction of malignant and benign lesions like number of vessels (p < 0.05), distribution of tumoral vessels, morphology of vessels and resistivity index values higher than 0.85 showed statistically significant difference (p < 0.001). When sonographic findings were combined with PDUS and spectral analysis findings, sensitivity, specificity, PPV and NPV were 100%, 52.7%, 60% and 100%, respectively.

Conclusion

PDUS and spectral analysis have no contribution to BI-RADS US. For the spectral analysis, when RI value is one or greater, malignancy risk significantly increases.  相似文献   

6.

Purpose

To determine the diagnostic performance of Acoustic Radiation Force Impulse (ARFI) Virtual Touch IQ shear wave elastography in the discrimination of benign and malignant breast lesions.

Materials and methods

Conventional B-mode and elasticity imaging were used to evaluate 110 breast lesions. Elastographic assessment of breast tissue abnormalities was done using a shear wave based technique, Virtual Touch IQ (VTIQ), implemented on a Siemens Acuson S3000 ultrasound machine. Tissue mechanical properties were interpreted as two-dimensional qualitative and quantitative colour maps displaying relative shear wave velocity. Wave speed measurements in m/s were possible at operator defined regions of interest. The pathologic diagnosis was established on samples obtained by ultrasound guided core biopsy or fine needle aspiration.

Results

BIRADS based B-mode evaluation of the 48 benign and 62 malignant lesions achieved 92% sensitivity and 62.5% specificity. Subsequently performed VTIQ elastography relying on visual interpretation of the colour overlay displaying relative shear wave velocities managed similar standalone diagnostic performance with 92% sensitivity and 64.6% specificity. Lesion and surrounding tissue shear wave speed values were calculated and a significant difference was found between the benign and malignant populations (Mann–Whitney U test, p < 0.0001). By selecting a lesion cut-off value of 3.31 m/s we achieved 80.4% sensitivity and 73% specificity. Applying this threshold only to BIRADS 4a masses, we reached overall levels of 92% sensitivity and 72.9% specificity.

Conclusion

VTIQ qualitative and quantitative elastography has the potential to further characterise B-mode detected breast lesions, increasing specificity and reducing the number of unnecessary biopsies.  相似文献   

7.

Aim

To evaluate the diagnostic performance of the combined use of elstosonography (USE) scoring and high-resolution ultrasonography (HRUS) for the differentiation of benign and malignant thyroid nodule.

Patients and methods

Forty-seven consecutive patients with 66 thyroid nodules were enrolled in the present study. Thyroid surgery had been already planned for all the patients. All of them were submitted to high-resolution ultrasonography and elastography scoring at the same sitting. The latter was determined with 5-point scoring method. The examination results were compared against pathological findings as the gold standard of reference.

Results

The sensitivity, specificity, accuracy, positive predictive, and negative predictive values of HRUS in the differential diagnosis of thyroid nodules were 92.0%, 72.9%, 60.1%, 95.0%, and 63.1%, respectively, while that of ultrasound elastography scoring were 75.4%, 85.5%, 86.7%, 71.4%, and 90.5%, respectively. Combined use of both US techniques resulted in a higher diagnostic performance as it showed 95.4%, 94.8%, 95.2%, 82.3% and 98.8% sensitivity, specificity, accuracy, positive predictive, and negative predictive values, respectively.

Conclusions

The use of combined USE and HRS for the differentiation of benign and malignant thyroid nodules resulted in a high diagnostic performance and a significant statistical difference as compared to HRUS or USE alone (P = 0.003).  相似文献   

8.

Objectives

The purpose of this study was to evaluate the diagnostic utility of real-time elastography (RTE) in differentiating between reactive and metastatic cervical lymph nodes (LN) in patients with primary head and neck cancer in comparison with the conventional B mode and power Doppler parameters.

Methods

A total of 127 lymph nodes in 78 patients with primary head and neck cancer were examined by B-mode sonography, power Doppler ultrasound and elastography. Elastographic patterns were determined on the distribution and percentage of the lymph node area with low elasticity (hard), with pattern 1 being an absent or very small hard area to pattern 5, a hard area occupying the entire lymph node. Patterns 3–5 were considered metastatic. Ultrasound guided aspiration cytology was done for 57 lymph nodes. Excision biopsy was done for 52 lymph nodes. Eighteen lymph nodes responded to conservative treatment, and were considered reactive.

Results

The majority (85.3%) of the metastatic lymph nodes had elastography pattern 3–5. This finding was observed in only 5% of the benign lymph nodes (P < 0.001). The elastography pattern had sensitivity of 85.3%, specificity of 95.5%, PPV of 97.2%, NPV of 78.1% and overall accuracy of 88.9% in differentiation between benign and malignant lymph nodes. On the other hand, for the B mode criteria, the best accuracy was given to abnormal hilum (83%). The accuracy of power Doppler ultrasound pattern was 70.8%.

Conclusions

The accuracy of sonoelastography is higher than usual B mode and power Doppler ultrasound parameters in differentiation between benign and malignant nodes. The integration of lymph node sonoelastography in the follow up of patients with known head and neck cancer may reduce the number of biopsies.  相似文献   

9.

Aim of the work

To study the diagnostic utility of real-time ultrasound elastography (USE) in predicting malignancy in thyroid nodules.

Materials and methods

Forty-five patients with solitary solid thyroid nodules were included in this study. The thyroid nodules were examined by B-mode ultrasound, color flow Doppler ultrasound, and real-time ultrasound elastography (USE). The final diagnosis was obtained from histopathological findings. Tissue stiffness on USE was scored from 1 (low stiffness over the entire nodule) to 6 (high stiffness over the entire nodule and surrounding tissue).

Results

Twenty-eight (62.2%) patients had a final diagnosis of malignancy based on histopathological evidence of malignant thyroid nodules, while 17 (37.8%) were diagnosed as benign nodules. Anteroposterior/transverse (AP/T) diameter more than 1 cm, ill-defined margins and spot micro calcifications were the most predictive conventional ultrasound patterns of malignancy. Elasticity score of 4–6 was highly predictive of malignancy (P < 0.0001), with a sensitivity of 89.3%, a specificity of 88.2% and an accuracy of 88.9%.

Conclusion

Ultrasound elastography is an accurate non invasive tool for evaluating thyroid nodules. It has more appropriate value in the differential diagnosis of thyroid malignancy and enhances the diagnostic assurance of ultrasonographers.  相似文献   

10.

Objective

To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI).

Materials and methods

From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2).The clinical impact of second-look US was studied in terms of negative predictive value (NPV).

Results

The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05).

Conclusions

The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.  相似文献   

11.

Objective

To prospectively evaluate the diagnostic efficacy of conventional ultrasound (US), contrast-enhanced US (CEUS), the combined use of two modalities, and magnetic resonance imaging (MRI) in the differentiation of focal solid breast lesions.

Materials and methods

61 patients with BI-RADS category 3–5 breast lesions detected at conventional US underwent CEUS and MRI. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of conventional US, CEUS, combination of two modalities and MRI for discrimination between benign and malignant breast lesions.

Results

Tissue specimens of 61 breast lesions were obtained either from surgical resection (n = 46) or from needle biopsy (n = 15). Histopathologic diagnosis revealed 28 benign and 33 malignant lesions. The diagnostic performance of conventional US and CEUS in differentiating benign from malignant breast lesions showed no significant difference (P = 0.741). The combination of two modalities significantly improved the diagnostic accuracy compared with either conventional US or CEUS alone (P = 0.031 and P = 0.012, respectively). The area under the ROC curve (Az) value for the combined use of two modalities for discrimination between benign and malignant breast lesions was 0.94, and that for MRI was 0.91, whereas no statistical difference was found between them (P = 0.296).

Conclusion

The combined use of conventional US and CEUS has a better diagnostic performance than either method alone and displays good agreement with MRI in the differentiation capability for benign and malignant breast lesions.  相似文献   

12.

Background

Cervical adenopathy is a common problem and the differentiation of benign and malignant node is of crucial importance for therapy management.

Objective

This prospective study aimed to know if Diffusion weighted images (DWI) and apparent diffusion coefficient (ADC) can differentiate benign from malignant cervical lymphadenopathy.

Patients and methods

Thirty patients with cervical adenopathy were included in this study. Doppler ultrasound, DWI and ADC maps were automatically reconstructed and used for the measurement of ADC values.

Results

The sensitivity and specificity of the RI cut-off value <0.69 in differentiation between benign and malignant cervical L.Ns was 88.8% and 71.4%, respectively. The optimal ADC cut off value for differentiation between benign and malignant lymph nodes was ?1.0 × 10−3 mm2/s with an accuracy 96.7%, a sensitivity 100%, a specificity 88.9%, PPV 95.4% and NPV 100% and statistically significant P-value = 0.000.

Conclusion

DWI and ADC were useful for differentiation between benign and malignant cervical lymphadenopathy and recommended to decrease the need of invasive biopsies. However, CDUS techniques can be used as preliminary technique but, they had potential pitfalls in diagnosis of malignant cervical lymphadenopathy cases.  相似文献   

13.

Purpose

This study was undertaken to evaluate the role of ultrasound (US) elastography in characterising focal breast lesions classified as indeterminate on B-mode US.

Materials and methods

Eighty-four focal breast lesions, 64 benign and 20 malignant (mean diameter, 15.1 mm), detected but not characterised on B-mode US in 72 women, Breast Imaging Reporting and Data System (BI-RADS) US category 3 (n=56) or category 4 (n=28), were studied with US elastography and classified in consensus by two radiologists according to a five-point colour scale. Sensitivity, specificity and positive and negative predictive values (PPV and NPV) of US elastography compared with conventional US were calculated in relation to microhistology (n=67) and cytology (n=17), which were used as the reference standard.

Results

A total of 65/84 (77.4%) lesions were correctly classified as benign or malignant using US elastography, whereas the remaining 19/84 (22.6%) were incorrectly assessed. There were no statistically significant differences between US elastography and B-mode US with regard to sensitivity (70% vs. 68.4%), specificity (79.6% vs. 78.5%), PPV (51.8% vs. 48.1%) and NPV 89% vs. 89.5% (p>0.5). By contrast, a statistically significant difference was noted in the evaluation of BI-RADS 3 lesions, in which US elastography had 50% sensitivity, 86% specificity, 30% PPV and 93.5% NPV compared with BI-RADS 4 lesions (78.6%, 57.1%, 64.7% and 72.7%) (p<0.5).

Conclusions

The high NPV of US elastography may help reduce the use of biopsy in BI-RADS 3 lesions, but its low PPV in BI-RADS 4 lesions does not allow avoidance of biopsy on the basis of the US elastographic score alone in this group of lesions.  相似文献   

14.

Purpose

To detect axillary lymph node metastasis based on diffusion Weighted MR and apparent diffusion coefficient (ADC) in the known breast cancer cases.

Patient and methods

Forty-four patients were included in this study for preoperative MRI staging of the breast cancer and axillary lymph node assessment. The lymph node criteria (long/short-axis ratio, T2WI, DWI and ADC value) were included in the analysis. Images were obtained with diffusion sensitizing gradients of 0 and 750 mm2/s. The ADC was calculated.

Results

Thirty-two patients had metastatic axillary lymph nodes and 12 cases had no malignant LN involvement. There was no significant difference between both in S/L ratio, T2WISI (p < 0.140 & p = 0.079, respectively), while statistically significant difference between benign and malignant lymph nodes in both DWI and ADC mean values (p < 0.0001 & p < 0.007, respectively). The optimal ADC cut off value was ?.8 × 10−3 mm2/s for differentiation between benign and malignant lymph nodes with accuracy 96.7%, sensitivity 100%, specificity 87%, PPV 95.4% and NPV 100%.

Conclusion

Compared with lymph node size or routine magnetic resonance sequences, DWI and ADC are promising techniques for differentiating metastatic and non metastatic axillary lymph nodes in known breast cancer patients.  相似文献   

15.
16.

Purpose

To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses

Materials and methods

101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (Ehomo) and six-point color score of maximum elasticity (Ecol). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity.

Results

A visual color pattern, Ehomo, Ecol and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, Ecol, Ehomo and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and Ecol showed significantly higher AUC than Ehomo. In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, Ehomo, but no significant difference was found in Ecol.

Conclusion

Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE.  相似文献   

17.

Objective

To comparatively evaluate shear wave elastography (SWE) and real-time elastography (RTE) in distinguishing malignant from benign thyroid nodules.

Methods

49 patients with 64 focal thyroid nodules were enrolled and underwent SWE and RTE before surgery. SWE elasticity indices (mean, minimum and maximum value of 2-mm region of interest) of nodules were measured. For RTE, elastograms were assessed by Rago criteria and nodules with scores of 4 or 5 were classified as suspicious for malignancy. Surgery histopathologic results were adopted as diagnostic standard.

Results

Of the 64 nodules, 19 were papillary thyroid carcinomas and 45 were benign. SWE indices were significantly higher in malignant than benign nodules (P < 0.05). Areas under the ROC curves (AUC) of SWE parameters were 0.840, 0.831 and 0.788, which were not significantly different from that of RTE showed as 0.880 (P = 0.148–0.482). When the most accurate cut-off, 38.3 kPa for mean value was applied to predict malignancy, the diagnostic specificity, sensitivity, accuracy, positive predictive value and negative predictive value of SWE and RTE were 68.4% versus 79.0%, 86.7% versus 84.4%, 81.3% versus 78.1%, 68.4% versus 64.7% and 86.7% versus 83.3%, respectively (P = 0.683–1.000).

Conclusion

SWE as a promising tool can be performed in differentiating thyroid nodules with comparable results to RTE.  相似文献   

18.

Aim of the work

To evaluate the prognostic value and accuracy of PET/CT in DLBCL patients with post-treatment CT-residual masses with concern in overall (OAS) and progression-free survival (PFS).

Materials and methods

We retrospectively studied 62 patients with DLBCL who had CT documented residual masses (CRu) after completion of chemotherapy.

Results

Forty-four patients with negative PET scan were free of relapse while 4 out of 18 patients with positive scan showed CR, the other 14 patients had developed relapse. PET attained a sensitivity of 100%, a specificity of 91%, a NPV of 100% and a PPV of 77.8% and an accuracy of 93.5%. The median OAS time was 33.59 months in patients with negative scan and 19.00 months in patients with positive scan with highly significant correlation (P value 0.0001) and the median PFS time was 29.53 months in patients with negative scan versus only 4.00 months in patients with positive scan with highly significant correlation (P value 0.0000).

Conclusion

PET/CT plays helpful part in evaluation of therapy response in DLBCL patients with CT residual mass and post-chemotherapy PET could be used as an accurate and good predictor of OAS and PFS.  相似文献   

19.

Objective

To determine the benefit of DWI in diagnosis of benign and malignant solid or predominantly solid gynecological adnexal or ovarian masses.

Material and Methods

This study is carried out on 23 patients with histologically proven solid or predominantly solid adnexal or ovarian masses out of which 5 cases (21.8%) have benign and 18 cases (78.2%) have malignant neoplasms. Among these 19 cases (82.6%) have unilateral disease and 4 cases (17.4%) have bilateral disease which was metastatic ovarian carcinoma.

Result

On DWI, high signal intensity is noted in malignant lesion more frequently than in benign lesion. (P < 0.001) in adnexal lesions, while in ovarian lesions (P = 0.001).The differentiation between benign and malignant adnexal lesions revealed no significant difference in the apparent diffusion coefficient (ADC) value (P = 0.22).

Conclusion

DWI is a helpful tool in differentiation between predominantly solid and solid benign and malignant adnexal lesions because there is an increased frequency of higher signal intensity (diffusion restriction) in malignant lesions.  相似文献   

20.

Objective

To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances.

Methods

From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21–88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared.

Results

Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P < 0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5–89.8% to 100.0%, while specificity was significantly improved: 62.5–81.7% to 13.9% (P < 0.001). Area under the ROC curve (Az) did not show significant differences between grayscale US to US combined to SWE (P > 0.05).

Conclusion

Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号