首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The bioavailability of a new losartan preparation (2-butyl-4-chloro-1-[p-(o-1H-tetrazol-5-ylphenyl)benzyl]imidazole-5-methanol monopotassium salt, CAS 114798-26-4) was compared with the reference preparation of the drug in 24 healthy male volunteers, aged between 19 and 32. The open, randomized, single-blind two-sequence, two-period crossover study design was performed. Under fasting conditions, each subject received a single oral dose of 100 mg losartan as a test or reference formulation. The plasma concentrations of losartan and its active metabolite were analyzed by a rapid and sensitive HPLC method with UV detection. The pharmacokinetic parameters included AUC0-36h, AUC0-infinity, Cmax, t1/2, and Ke. Values of AUC0-infinity demonstrate nearly identical bioavailability of losartan from the examined formulations. The AUC0-infinity of losartan was 2019.92+/-1002.90 and 2028.58+/-837.45 ng x h/ml for the test and reference formulation, respectively. The AUC0-infinity of the metabolite was 10851.52+/-4438.66 and 11041.18 +/-5015.81 ng x h/ml for test and reference formulation, respectively. The maximum plasma concentration (Cmax) of losartan was 745.94+/-419.75 ng/ml for the test and 745.74+/-329.99 ng/ml for the reference product and the Cmax of the metabolite was 1805.77+/-765.39 and 1606.22 +/-977.22 ng/ml for the test and reference product, respectively. No statistical differences were observed for Cmax and the area under the plasma concentration-time curve for both losartan and its active metabolite. 90 % confidence limits calculated for Cmax and AUC from zero to infinity (AUC0-infinity) of losartan and its metabolite were included in the bioequivalence range (0.8-1.25 for AUC). This study shows that the test formulation is bioequivalent to the reference formulation for losartan and its main active metabolite.  相似文献   

2.
This investigation was carried out to evaluate the bioavailability of a new suspension formulation of cefixime (100 mg/5 ml), Winex, relative to the reference product, Suprax (100 mg/5 ml) suspension. The bio-availability study was carried out in 24 healthy male volunteers who received a single oral dose (200 mg) of the test (A) and the reference (B) products on 2 treatment days after an overnight fast of at least 10 hours. The treatment periods were separated by a one-week washout period. A randomized, balanced two-way crossover design was used. After dosing, serial blood samples were collected over a period of 16 hours. Plasma concentrations of cefixime were analyzed using a sensitive high-performance liquid chromatographic assay. The pharmacokinetic parameters for cefixime were determined using standard non-compartmental method. The parameters AUC(0-t), AUC(0-infinity), Cmax, Kel, t1/2 and Cmax/AUC(0-infinity) were analyzed statistically using raw and log-transformed data. The time to maximum concentration (tmax) was analyzed using raw data. The parametric 90% confidence intervals of the mean values of the pnfinity harmacokinetic parameters: AUC(0-t), AUC(0-infinity) Cmax, and Cmax/AUC(0-infinity) were within the range 80 - 125% which is acceptable for bioequivalence (using log-transformed data). The calculated 90% confidence intervals based on the ANOVA analysis for the mean test/reference ratios of AUC(0-t), AUC(0-infinity), Cmax, and Cmax/AUC(0-infinity) were 88.93 - 107.10%, 89.09 - 107.11%, 89.63 - 108.58% and 96.85 - 105.29%, respectively. The test formulation was found bioequivalent to the reference formulation with regard to AUC(0-t), AUC(0-infinity), and Cmax using the Schuirmann's two one-sided t-tests. Therefore, the two formulations were considered to be bioequivalent.  相似文献   

3.
Relative bioavailability of three cefixime formulations   总被引:2,自引:0,他引:2  
Three galenic formulations of cefixime (tablet, syrup and dry suspension) containing 200 mg each were compared with respect to their relative bioavailability in twelve healthy volunteers. All three formulations showed reliable absorption. Mean peak plasma concentrations were reached after 3.3-3.5 h, mean terminal half lives were 2.9-3.1 h. 18-24% of the dose administered were recovered unchanged in the urine. Best bioavailability was obtained with the dry suspension (AUC0-infinity = 25.8 +/- 7.0 micrograms/ml h; Cmax = 3.4 +/- 0.9 microgram/ml), followed by the tablet (AUC0-infinity = 20.9 +/- 8.1 micrograms/ml h; Cmax = 3.0 +/- 1.0 micrograms/ml) and the syrup which is based on triglycerides (AUC0-infinity = 17.8 +/- 5.9 micrograms/ml h; Cmax = 2.4 +/- 0.7 micrograms/ml). The statistical analysis resulted in bioinequivalence between dry suspension and syrup. It is concluded that best bioavailability of cefixime after oral administration is guaranteed when taken in an "aqueous medium" either as dry suspension or as tablet with "plenty of liquid".  相似文献   

4.
Two different finasteride (CAS 98319-26-7) tablet formulations were evaluated for their relative bioavailability (Flaxin tablets 5 mg, as the test formulation vs reference formulation, tablets 5 mg) in 23 healthy male volunteers who received a single 5 mg oral dose of each preparation. The study was open, randomized with a two-period crossover design and a 7-day washout period. Plasma samples were obtained over a 48-h interval. The finasteride concentrations were determined by high-pressure liquid chromatography (HPLC) coupled to tandem mass spectrometry (LC-MS-MS). The analytical method developed has a limit of quantitation (LOQ) of 0.50 ng/ml in plasma. For the quality control the measured concentration was 2.05 +/- 0.14 ng/ml (mean +/- SD, n = 30) with a precision of 6.9% and an accuracy of 2.55% at a concentration of the starting solution of 2.00 ng/ml, while with 20.00 ng/ml starting solution the measured concentrations were 20 +/- 0.80 ng/ml (n = 30) with a precision of 3.81% and an accuracy of 0.09%. From the plasma finasteride concentration vs time curves the following pharmacokinetics parameters were obtained: AUC0-48, AUC0-infinity, Cmax, Cmax/AUC0-48, Ke, elimination half-life and tmax. Geometric mean test/reference formulations individual percent ratio was 95.71 for AUC0-48 h and 88.70% for Cmax. The 90% confidence interval for the geometric mean of the individual ratio test/reference formulations was 95.70-120.20% for AUC0-48 h, 94.60-121.30 for AUC0-infinity and 88.70-108% for Cmax. Since for both Cmax or AUC the 90% Cl values are within the interval proposed by the Food and Drug Administration, the test formulation is bioequivalent to the reference formulation for both the rate and extent of absorption after single dose administration.  相似文献   

5.
The pharmacokinetics and relative bioavailability/bioequivalence of two formulations of digoxin (CAS 20830-75-5) were assessed in this paper. The study was conducted in 20 healthy Chinese male volunteers according to an open, randomized, single-blind, 2-way crossover study design with a wash-out phase of 14 days. Blood samples for pharmacokinetic profiling were taken up to 72 h post-dose and digoxin plasma concentrations were determined by a validated liquid chromatography-tandem mass spectrometry (LCMS/MS) method. Based on the plasma concentration-time data of each individual during two periods, pharmacokinetic parameters, Cmax, AUC0-tau, AUC0-infinity and t1/2, were calculated by applying noncompartmental analysis. Pharmacokinetic data for test and reference formulations were analyzed statistically to evaluate bioequivalence of the two formulations. After oral administration, the values of Cmax Tmax, t1/2, AUC0-tau, AUC0-infinity for test and reference formulations were 2.61 +/- 0.98 and 2.68 +/- 1.09 ng/ mL, 1.0 +/- 0.4 and 1.0 +/- 0.4 h, 27.94 +/- 3.14 and 27.56 +/- 3.86 h, 28.57 +/- 4.99 and 28.77 +/- 6.53 ng x h/mL, 33.44 +/- 4.85 and 33.63 +/- 7.57 ng x h/mL, respectively. Both primary target parameters, AUC0-infinity and AUC0-tau, were tested parametrically by analysis of variance (ANOVA). Relative bioavailabilities were 102.5 +/- 19.2% for AUC0-infinity, 102.0 +/- 19.3% for AUC0-tau. Bioequivalence between test and reference formulations was demonstrated for both parameters, AUC0-infinity and AUC0-tau. The 90% confidence intervals of the T/R-ratios of logarithmically transformed data were in the generally accepted range of 80%-125%, which means that the test formulation is bioequivalent to the reference formulation of digoxin.  相似文献   

6.
Azithromycin (AZT; CAS 83905-01-5) is an efficient antibiotic and is widely prescribed in Bangladesh. The taste of uncoated AZT suspension is bitter. Although several taste masked oral suspensions of AZT are available in Bangladesh, information regarding the bioavailability of these formulations in Bangladeshi population is unavailable. The purpose of this study was to compare the relative bioavailability and other pharmacokinetic properties of two oral formulation of AZT (200 mg/5 ml) suspensions, the uncoated reference product and coated test product (Tridosil 200 mg/5 ml) and to evaluate whether these formulations meet the FDA criteria to assume bioequivalence in Bangladeshi male volunteers. A randomized, single-dose, two-way cross-over, open-label pharmacokinetic study was conducted in 24 healthy male volunteers after administration of a single dose of 500 mg AZT suspension under fasting condition following a washout period of three weeks. Blood samples were collected in different time intervals and analyzed for serum AZT concentration using a validated LC/MS/MS method. The pharmacokinetic parameters were determined by the non-compartmental method. From serum data, the obtained values for test and reference products were 383.21 +/- 11.59 and 432.28 +/- 7.22 ng/ ml for Cmax; 5677.47 +/- 1229.53 and 6144.56 +/- 1098.70 h x ng/ml for AUC(0-120); and 6085.29 +/- 1267.53 and 6694.15 +/- 1222.50 h x ng/ml for AUC(0-infinity), respectively. On analysis of variance, no period or sequence effects were observed for any pharmacokinetic property; however, a significant formulation effect was observed for Cmax and AUMC(0-infinity). The 90% confidence intervals of the test formulation/reference mean ratios of the Intransformed Cmax, AUC(0-120) and AUC(0-infinity) mean values were found to be 87.89% to 89.36%, 87.96% to 95.71% and 86.77% to 94.29% respectively. In this single-dose study of AZT, it was found that the test formulation met the regulatory criteria for bioequivalence to the reference suspension formulation.  相似文献   

7.
The aim of the present study was to compare the bioavailability of doxycycline (CAS 564-25-0) from two different doxycycline hyclate (CAS 24390-14-5) capsules (Monodoks 100 mg capsule as test preparation and 100 mg capsule of the originator product as reference preparation) in 24 healthy male subjects. The study was conducted according to an open-label, randomised two-period cross-over design with a wash-out phase of 16 days. Blood samples for pharmacokinetic profiling were taken up to 72 h post-dose, and doxycycline plasma concentrations were determined with a validated HPLC method with UV-detection. Maximum plasma concentrations (Cmax) of 1,715.1 ng/ml (test) and 1,613.3 ng/ml (reference) were achieved. Areas under the plasma concentration-time curve (AUC(0-infinity)) of 28,586.5 ng x h/ml (test) and 29,047.5 ng x h/ml (reference) were calculated. The median tmax was 1.88 h (test) and 2.00 h (reference). Plasma elimination half-lives (t1/2) of 16.49 h (test) and 16.75 h (reference) were determined. Both primary target parameters AUC(0-infinity) and Cmax were tested parametrically by analysis of variance (ANOVA) and the 92.39 %-103.53% (AUC(0-infinity)) and 98.45%-111.74% (Cmax). Bioequivalence between test and reference preparation was demonstrated since for both parameters AUC and Cmax the 90% confidence intervals of the T/R ratios of logarithmically transformed data were in the generally accepted range of 80 0%-125%.  相似文献   

8.
The aim of the present study was to compare the bioavailability of ranitidine (CAS 66357-35-5) from two different ranitidine hydrochloride (CAS 66357-59-3) film tablets (Ranitab 150 mg film tablets as test preparation and 150 mg film tablets of the originator product as reference preparation). The study was conducted according to an open-label, randomised two-period cross-over design with a wash-out phase of 9 days. Blood samples for pharmacokinetic profiling were taken up to 24 h post-dose, and ranitidine plasma concentrations were determined with a validated HPLC method with UV-detection. Maximum plasma concentrations (Cmax) of 461.8 ng/ml (test) and 450.6 ng/ ml (reference) were achieved. Areas under the plasma concentration-time curve (AUC (0-infinity) of 2,488.6 ng . h/ml (test) and 2,528.8 ng . h/ml (reference) were calculated. The median tmax was 2.83 h (test) and 3.04 h (reference). Plasma elimination half-lives (t1/2) of 2.78 h (test) and 2.89 h (reference) were determined. Both primary target parameters AUC(0-infinity) and Cmax were tested parametrically by analysis of variance (ANOVA) and the 90% confidence intervals were between 91.93 %-106.98 % (AUC (0-infinity) and 92.34%-118.85% (Cmax). Bioequivalence between test and reference preparation was demonstrated since for both parameters AUC and Cmax the 90 % confidence intervals of the T/R ratios of logarithmically transformed data were in the generally accepted range of 80 %-125 %.  相似文献   

9.
The bioavailability of drotaverine (CAS 14009-24-6) was investigated after oral administration of a drotaverine capsule preparation (20 mg Droxa mite) and compared to that of a reference tablet preparation. The preparations were investigated in 23 healthy volunteers, aged between 20 and 27 years, according to a randomised two-way, cross-over design in the fasted state. Blood samples for determination of drotaverine plasma concentrations were collected at pre-defined time points up to 30 h following drug administration. A washout period of two weeks separated both treatment periods. Drotaverine plasma concentrations were determined by means of a validated HPLC method (UV detector, imipramine HCl salt as an internal standard). The limit of detection was 6 ng/ml. Values of 1593.92 +/- 949.70 ng x h/l (95% confidence interval (CI): 1183.20-2004.60) for the test and 1705.48 +/- 737.78 ng x h/l (95% CI: 1386.40-2024.50) for the reference preparation AUC(0-infinity) demonstrate a nearly identical extent of drug absorption. Maximum concentrations--Cmax of 121.89 +/- 37.03 ng/ml (95% CI: 104.05-139.80) and 121.85 +/- 37.97 ng/ml (95% CI: 107.09-135.74) and time to reach maximum plasma concentration--Tmax of 1.29 +/- 0.42 h (95% CI: 1.11-1.48) and 1.14 +/- 0.34 h (95% CI: 0.99-1.29) achieved for the test and reference preparations did not differ significantly. The relative bioavailability (AUC(0-infinity) ratio test/reference) and Cmax ratio test/reference were 103.15% (90% CI: 81.68-124.60) and 103.74% (90% CI: 94.10-113.38), respectively. AUC was calculated using two different methods. There were no significant differences between the obtained values. Since the 90% CI for both, AUC and Cmax ratios were within the 80-125% interval proposed by the European Agency for the Evalution of Medicinal Products (CPMP) and the Food and Drug Administration, it is concluded that the new drotaverine capsule formulation is therapeutically equivalent to the conventional formulation for both, the extent and the rate of absorption after single dose administration in healthy volunteers.  相似文献   

10.
Triflusal (CAS 322-79-2) is an antiplatelet agent related to salicylates used in several European and Latin American countries in the treatment of cardiovascular diseases. The aim of this paper was to evaluate the bioequivalence of triflusal derived from two preparations using both parent drug and metabolite pharmacokinetic data. The bioavailabolity was measured in 24 healthy male Caucasian volunteers following a single oral dose (600 mg) of the test or reference products in the fasting state. Blood samples were collected for 120 h. Plasma concentrations of triflusal and its metabolite 3-hydroxy-4-trifluoromethylbenzoic acid (HTB) were analyzed by high-performance liquid chromatography with UV and fluorescence detection, respectively. The non-compartmental method was used for pharmacokinetic analysis. Log-transformed Cmax, AUC0-t and AUC0-infinity were tested for bioequivalence using ANOVA and Schuirmann's two-one sided t-test. Tmax was analyzed by nonparametric pharmacokinetic parameters of triflusal and HTB derived from the two formulations were nearly consistent with previous observations. Triflusal parameters derived from the test and reference drug were as follows: Cmax (16.85 +/- 11.41 vs 14.48 +/- 7.22 mg/l), AUC0-t (18.43 +/- 10.91 vs 16.22 +/- 7.58 mg/l per hour), Tmax (1 range 0.25-2h vs 0.875 range 0.25-1.5 h), and t(1/2) (0.49 +/- 00.27 vs 0.76 +/- 0.64). HTB parameters after test and reference formulation administration were as follows: Cmax (68.13 +/- 23.05 vs 65.51 +/- 19.44 mg/l), AUC0-t (2748.18 +/- 971.91 vs 2877.97 +/- 881.2 h x mg/l), AUC0-infinity (3350.15 +/- 1182.62 vs 3372.49 +/- 1110.35 h x mg/l), Tmax (2 range 1-10 h vs 2 range 0.75-12 h), and t(1/2) (42.19 +/- 7.82 vs 43.13 +/- 6.56 h). 90% of confidence intervals for the test/reference ratio of Cmax AUC0-t and AUC0-infinity derived from both triflusal and HTB were found within the range of 80%-125% acceptable for bioequivalence. No significant difference was found between the Tmax values for triflusal and HTB. It was concluded that the two preparations are bioequivalent and may be prescribed interchangeably.  相似文献   

11.
This investigation was carried out to evaluate the bioavailability of a new capsule formulation of doxycycline (100 mg), doxycin, relative to the reference product, vibramycin (100 mg) capsules. The bioavailability was carried out in 24 healthy male volunteers who received a single dose (100 mg) of the test (A) and the reference (B) products after an overnight fast of at least 10 hours on 2 treatment days. The treatment periods were separated by a 2-week washout period. A randomized, balanced 2-way cross-over design was used. After dosing, serial blood samples were collected for a period of 48 hours. Plasma concentrations of doxycycline were analyzed by a sensitive and validated high-performance liquid chromatography assay. The pharmacokinetic parameters for doxycycline were determined using standard noncompartmental methods. The parameters AUC(0-t), AUC(0-infinity), Cmax, K(el), t(1/2) and Cmax/AUC(0-infinity) were analyzed statistically using log-transformed data. The time to maximum concentration (tmax) was analyzed using raw data. The parametric 90% confidence intervals of the mean values of the pharmacokinetic parameters: AUC(0-t), AUC(0-infinity), Cmax and Cmax/AUC(0-infinity) were within the range 80-125% which is acceptable for bioequivalence (using log-transformed data). The calculated 90% confidence intervals based on the ANOVA analysis of the mean test/reference ratios of AUC(0-t), AUC(0-infinity), Cmax and Cmax/AUC(0-infinity) were 95.98-109.56%, 92.21 to 107.66%, 93.90-112.56%, and 96.0 to 106.91% respectively. The test formulation was found bioequivalent to the reference formulation with regard to AUC(0-t), AUC(0-infinity), Cmax and Cmax/AUC(0-infinity) by the Schuirmann's two 1-sided t-tests. Therefore, the 2 formulations were considered to be bioequivalent.  相似文献   

12.
Two different tablets containing amlodipine besylate (CAS 111470-99-6) (Vazkor 10 mg tablet as test preparation and 10 mg tablet of the originator product as reference preparation) were investigated in 18 healthy male volunteers in order to compare the bioavailability and prove the bioequivalence between both treatments after oral single dose administration. The study was performed according to an open-label, randomized, two-period cross-over design with a wash-out phase of 21 days. Blood samples for pharmacokinetic profiling were taken up to 144 h post-dose, and amlodipine plasma concentrations were determined with a validated LC-MS/MS method. Maximum plasma concentrations (Cmax) of 6,183.7 pg/ml (test) and 5,366.7 pg/ml (reference) were achieved. Areas under the plasma concentration-time curve (AUC(0-infinity)) of 267,231.0 pg x h/ml (test) and 266,061.7 ng x h/ml (reference) were calculated. The median tmax was 5.6 h (test) and 6.1 h (reference). Plasma elimination half-lives (t 1/2) were 46.46 h (test) and 45.34 h (reference). Both primary target parameters AUC(0-infinity) and Cmax were tested parametrically by analysis of variance (ANOVA); 90% confidence intervals were between 93.20%-107.16% (AUC(0-infinity) and 103.36%-123.13% (Cmax). Bioequivalence between test and reference preparation was demonstrated since for both parameters AUC and Cmax the 90% confidence intervals of the T/R-ratios of logarithmically transformed data were in the generally accepted range of 80%-125%.  相似文献   

13.
The aim of the present study was to compare the bioavailability of clindamycin (CAS 18323-44-9) from three clindamycin hydrochloride (CAS 21 462-39-5) capsules (clindamycin 75 mg capsule as test 1 preparation, 150 mg capsule as test 2 preparation and a commercially available original 150 mg capsule of the drug as reference preparation) in 24 Chinese healthy male volunteers, aged between 22 and 28. The study was conducted according to a randomized, double-blind, 3-period, 3-treatment, 3-sequence, single-dose, crossover design with a wash-out phase of 7 days. Blood samples for pharmacokinetic profiling were taken up to 14 h post-dose, and clindamycin plasma concentrations were determined with a validated liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method. Maximum plasma concentrations (C(max)) of 3.06 +/- 1.10 microg/mL (test 1), 3.10 +/- 1.59 microg/mL (test 2) and 3.06 +/- 1.15 microg/mL (reference) were achieved. Areas under the plasma concentration-time curve (AUC(0-infinity)) of 10.73 +/- 4.29 microg x h/mL (test 1), 10.54 +/- 4.10 microg x h/ mL (test 2) and 11.29 +/- 4.98 microg x h/mL (reference), AUC(0-t) of 10.32 +/- 4.09 microg x h/ mL, 10.26 +/- 3.96 microg x h/mL, 10.94 +/- 4.86 g x h/mL were calculated. The median T(max) was 0.80 +/- 0.52 h, 0.77 +/- 0.37 h, 1.01 +/- 0.6 h for test 1, test 2 and reference formulation, respectively. Plasma elimination half-lives (t1/2) of 2.72 +/- 0.58 h (test 1), 2.39 +/- 0.37 h (test 2) and 2.63 +/- 0.66 h (reference) were determined. Both primary target parameters, AUC(0-infinity) and AUC(0-t) were tested parametrically by analysis of variance (ANOVA) and relative bioavailabilities were 98.0 +/- 16.2% (test 1) and 97.2 +/- 20.3% (test 2) for AUC(0-infinity), 97.5 +/- 16.3% (test 1) and 97.8 +/- 20.2% (test 2) for AUC(0-t). Bioequivalence between test and reference preparation was demonstrated for both parameters, AUC(0-infinity) and AUC(0-t). The 90% confidence intervals of the T/R-ratios of logarithmically transformed data were in the generally accepted range of 80%-125%. That means that the two test formulations are bioequivalent to the reference formulation for clindamycin.  相似文献   

14.
The bioequivalence of a test formulation (Nanopril, "test") and a reference formulation ("reference") of lisinopril (CAS 83915-83-7) was demonstrated by in vivo and in vitro tests. The in vivo bioequivalence study in 26 healthy volunteers was designed as a single dose, randomized, double-blind trial with a 2-week washout period between the doses. Prior to the in vivo study, an in vitro comparative dissolution test was performed by the paddle method following the bioequivalence guidance of the Korea Food and Drug Administration (KFDA). By the results of the dissolution test it was demonstrated from the similar and rapidly dissolving patterns of the two lisinopril tablets that the two formulations were pharmaceutically equivalent. However, the in vivo bioequivalence study was required to fully evaluate the bioequivalence of the two drug products. In the in vivo bioequivalence study, the plasma samples drawn from the volunteers were analyzed utilizing a sensitive LC-MS-MS analysis method and the bioequivalence between the two drug products was assessed by statistical analysis of the log transformed mean ratios of Cmax,AUC(0-t) and AUC(0-infinity). The mean maximum concentration (Cmax) of the test and reference were found to be 60.41 +/- 20.07 ng/mL and 61.11 +/- 19.36 ng/mL, respectively. The 90% confidence intervals (C.I.) of Cmax were in the range from 0.91 to 1.08. As for the AUC(0-t) and the AUC(0-infinity), test values were 792.73 +/- 273.41 ng x mL(-1) x h, 862.74 +/- 303.81 ng x mL(-1) x h and the reference values were 841.66 +/- 286.07 ng . mL(-1) x h, 906.97 +/- 318.72 ng x mL(-1) x h, respectively. The 90% C. I. of AUC(0-t) were 0.86 to 1.01 and of AUC(0-infinity), 0.87 to 1.02 and thus were within the 80-125% interval proposed by the FDA. In addition to the 90% C.I. of the pharmaceutical parameters, a two-way ANOVA showed no significant difference between the two formulations. Based upon these statistical analyses, it was concluded that the test formulation is bioequivalent to the reference.  相似文献   

15.
The bioavailability of a new terbinafine (CAS 91161-71-6) preparation was compared with a commercially available original preparation (reference) of the drug in 19 Chinese healthy male volunteers. The study was performed in an open, randomized, single blind two-sequence, two-period crossover design. Under fasting conditions, each subject received a single oral dose of 250 mg terbinafine as a test or reference formulation with a 7-day washout period between the two preparations. The plasma concentrations of terbinafine were analyzed by a sensitive liquid chromatography-ultraviolet spectrometry method. The pharmacokinetic parameters included AUC(0-t) AUC(0-infinity), C(max), t1/2, and T(max). The values of AUC(0-t) demonstrated nearly identical bioavailability of terbinafine from the examined formulations. The AUC(0.48) of terbinafine was 5982.85 +/- 2449.17 and 6761.63 +/- 3140.33 ng x h/ml for the test and reference formulation, respectively. The maximum plasma concentration (C(max)) of terbinafine was 1656.25 +/- 623.18 ng/ml for the test and 1552.07 +/- 660.35 ng/ml for the reference product, respectively. No statistical differences were observed for C(max) and the area under the plasma concentration time curve for terbinafine. The 90% confidence limits calculated for C(max) and AUC from zero to infinity (AUC(0-infinity)) of terbinafine were within the bioequivalence range (80%-125% for AUC). This study shows that the test formulation is bioequivalent to the reference formulation of terbinafine.  相似文献   

16.
The bioavailability of a new spironolactone ((7alpha,17alpha)-7-(acetylthio)-17-hydroxy-3-oxopregn-4-ene-21-carboxylic acid gamma-lactone, CAS 52-01-7) formulation (test) was compared with a commercially available original formulation (reference) of the drug in 20 Chinese healthy male volunteers, aged between 21 and 27. The trial was designed as an open, randomized, single blind two-sequence, two-period crossover study. Under fasting conditions, each subject received a single oral dose of 100 mg spironolactone as a test or reference formulation with a 7-day washout period between the two formulations. The plasma concentrations of spironolactone and its active metabolite canrenone (CAS 976-71-6) were analyzed by a sensitive liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) method. The pharmacokinetic parameters included AUC(0.t), AUC(0-infinity), C(max), t1/2, and T(max). Values of AUC(0-t) demonstrate nearly identical bioavailability of spironolactone from the examined formulations. The AUC(0.12) of spironolactone was 148.35 +/- 39.5 and 144.39 +/- 53.02 ng x h/ml for the test and reference formulation, respectively. The AUC(0-60) of the metabolite canrenone was 1873.36 +/- 318.10 and 1911.28 +/- 355.60 ng h/ml for test and reference formulation, respectively. The maximum plasma concentration (C(max)) of spironolactone was 48.34 +/- 21.16 ng/ml for the test and 47.40 +/- 23.40 ng/ml for the reference product and the C(max) of the metabolite was 122.90 +/- 27.70 and 123.35 +/- 27.29 ng/ml for the test and reference product, respectively. No statistical differences were observed for C(max) and the area under the plasma concentration-time curve for both spironolactone and its active metabolite canrenone. 90% confidence limits calculated for C(max) and AUC from zero to infinity (AUC(0-infinity)) of spironolactone and its metabolite were included in the bioequivalence range (80%-125% for AUC). This study shows that the test formulation is bioequivalent to the reference formulation for spironolactone and its main active metabolite canrenone.  相似文献   

17.
OBJECTIVE: To assess the bioequivalence of two fluoxetine hydrochloride capsule (20 mg) formulations (Fluoxicare capsule from Pharmacare Ltd., Chemicals and Cosmetics, Ramallah, Palestine, as test formulation, and Prozac from Eli Lilly Ltd., Basingstoke, UK, as reference formulation). DESIGN AND METHODS: The study was conducted open with a randomized 2-period crossover design and a 6-week washout period. Participants were 24 healthy male volunteers aged 18-28 years, divided into 2 groups of 12 subjects. One group was given the originator drug (reference formulation), and the other was given the test formulation. Blood samples were obtained at baseline and at 14 time points during the interval 0-96 hours after drug administration. The concentrations of the samples were assayed spectrophotometrically at 220 nm using a Shimadzu 160 A UV-visible spectrometer. We calculated the plasma concentration-time curve (AUC), maximum plasma concentration (Cmax), and time of maximum plasma concentration (tmax) for each subject. Logarithmic transformation of the AUC and Cmax was used for the statistical analyses and to assess the bioavailability of the two formulations, using analyses of variance (ANOVA) and Satherwait t-tests for unequal variances. The ANOVA performed of tmax in Cmax, and in AUC provided the appropriate intra-subject variance estimates to evaluate the 90% confidence intervals for the differences between study variables after administration of the test and reference formulations. Statistical analyses were conducted on AUC 0-4 as the extrapolated part of the AUC, a truncated area approach was adapted. RESULTS: The mean pharmacokinetic parameters for both of the drugs under study were as follows: Cmax = 61.24 (+/- 12.96) ng/ml for the test formulation, and for the reference formulation Cmax = 61.39 (+/- 14.1) ng/ml, the effects were statistically equivalent. The tmax for the test formulation was 8.25 (+/- 1.7) and 7.33 (+/- 0.96) for the reference formulation. The area under the curve to infinity (AUC 0-infinity (ng, day/ml)) for the test formulation and for the reference formulation were 293.02 (+/- 52.69) and 296.15 (+/- 61.69), respectively. CONCLUSIONS: The two formulations had equivalent pharmacokinetic parameters, were well-tolerated, and their relative bioavailability was 98.94%.  相似文献   

18.
AIM: To estimate the bioavailability and evaluate bioequivalence of a single dose of a dexibuprofen tablet (test formulation, containing dexibuprofen 400 mg, manufactured by Emcure Pharmaceuticals Ltd., Pune, India) and to compare it with that of a single dose of a Seractil tablet (reference formulation, containing dexibuprofen 400 mg, manufactured by Genus Pharmaceuticals, Bershire, UK) under fasting conditions. SUBJECTS AND METHODS: Using a two-treatment, two-period, two-sequence, randomized crossover design, test and reference formulations were administered as individual single doses to 24 healthy adult Asian male subjects of Indian origin under non-fed conditions, with 4 days washout period between dosing. 17 blood samples were drawn from each subject over a 12-hour period. Pharmacokinetic parameters, Cmax, AUC0-t, AUC0-infinity and Cmax/AUC0-infinity were calculated from the plasma concentration-time data of each individual and during each period by applying non-compartmental analysis. Analysis of variance was carried out using logarithmically transformed and non-transformed values of the stated pharmacokinetic parameters. Data for test and reference formulations were analyzed statistically to test for bioequivalence of the two formulations. RESULTS: All 24 subjects who received the two formulations on two occasions with a washout period of 4 days, completed the study and provided an adequate amount of blood at each sampling point. After oral administration the values of Cmax (microg/ml), tmax (h), AUC0-t (microg/ml x h), AUC0-infinity (microg/ml x h) for reference and test formulations were 23.501 and 22.948, 1.156 and 1.281, 69.795 and 68.455, and 72.454 and 70.208, respectively. ANOVA and CI test showed no significant (p > 0.05) variation in these pharmacokinetic parameters of test and reference formulations. When the AUC0-t values for both formulations for non-transformed and log-transformed data were compared, the test formulation showed a bioavailability of 98.08% and 99.56%, respectively, as compared to reference formulation. These values are within the acceptance limit of 80 - 120%. No adverse events were observed in any of the subjects during the two runs of the study. Both clinical and laboratory parameters of all subjects showed no clinically significant changes. CONCLUSION: The test formulation containing dexibuprofen 400 mg (manufactured by Emcure Pharmaceuticals Ltd., Pune, India) was bioequivalent to reference formulation (Seractil, manufactured by Genus Pharmaceuticals, Berkshire, UK). Both formulations were well tolerated. The test formulation can be considered a pharmaceutically and therapeutically equivalent alternative to Seractil.  相似文献   

19.
This work reports the bioavailability of two fluconazole (CAS 86386-73-4) capsule formulations in 24 healthy volunteers of both sexes who received a single oral dose (150 mg). The study was conducted using an open, randomized, two-period crossover design with two-week washout interval. Plasma samples were obtained up to 168 h after drug administration and fluconazole concentration were analyzed using electrospray tandem mass spectrometry coupled to liquid chromatography. The pharmacokinetic parameters obtained for fluconazole after the administration of each formulation included the area under the curve (AUC)(0-168 h), AUC(0-infinity), maximum concentration (Cmax), time to reach Cmax (Tmax), elimination constant (Ke) and half-life (T1/2). The 90% confidence interval for the geometric mean of the individual ratio test formulation/reference formulation were 97.18-108.60% for AUC0-168 h), 90.87-111.11% for AUC(0-infinity), 104.88-114.88% for Cmax 90.38-136.79% for Ke, 91.87-108.93% for T1/2 and (-)1.5-(-)0.10 for Tmax (for individual differences). Since for both Cmax or AUC the 90% CI are within the interval proposed by the Food and Drug Administration (FDA), the test formulation (Zoltrix) is bioequivalent to the reference formulation for both the rate and the extent of absorption after single dose administration.  相似文献   

20.
Two different oral methylprednisolone (CAS 83-43-2) formulations (Methylprednisolon-ratiopharm 8 mg tables as test preparation (T) and tablets of a reference preparation (R)) were investigated in 16 healthy volunteers in order to prove bioequivalence between these preparations. A single 8 mg oral dose was given according to a randomised two-way crossover design in the fasted state. Blood samples for determination of methylprednisolone plasma concentrations were collected at pre-defined time points up to 16 h following drug administration. A washout period of 3 days separated both treatment periods. Methylprednisolone plasma concentrations were determined by means of a validated HPLC method. Values of 342.53 ng.h/ml (test preparation) and 336.61 ng.h/ml (reference preparation) for the parameter AUC0-infinity demonstrate an nearly identical extent of drug absorption. Maximum concentrations (Cmax) of 66.58 ng/ml and 70.51 ng/ml were achieved for test and reference preparation. Time to reach maximum plasma concentration (tmax) was 2.2 h for both preparations. Cmax and AUC0-infinity-values were tested parametrically by the two one-sided t-test procedure. Bioequivalence was concluded if the 90% confidence intervals of the T/R-ratios were in the range of 80-125% for AUC0-infinity and 70-143% for Cmax. Based on the results obtained in this study, bioequivalence between Methylprednisolone ratiopharm and the reference preparation was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号