首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 171 毫秒
1.
目的 探讨巩膜瓣可调整缝线的小梁切除术对角膜散光的影响及术后屈光度稳定的时间.方法 收集2014年6月至2016年7月于我院眼科收治的70例原发性青光眼患者,将所有患者分为两组:试验组为联合可调整缝线的小梁切除术患者40例40眼,对照组为单纯小梁切除术者30例30眼.检查记录两组术前及术后1周(可调整缝线拆除前)、1个月、3个月的角膜地形图、角膜曲率、屈光度及眼压情况.结果 术后2组各时间点屈光度及眼压比较,差异均有统计学意义(均为P<0.01).术后1周角膜散光:试验组(3.80±1.31)D和对照组(1.42±0.32)D与术前(1.48±0.79)D、(1.12 ±0.36)D相比,差异均有显著统计学意义(均为P<0.01);试验组和对照组角膜散光术后1个月(1.50±0.71)D、(1.24 ±0.31)D及3个月(1.36±0.61)D、(1.09±0.34)D与术前相比,差异均无统计学意义(均为P>0.05),术后1周试验组与对照组角膜散光相比差异有显著统计学意义(P<0.01),术后1个月及3个月试验组与对照组角膜散光相比差异均无统计学意义(均为P>0.05).两组术后1个月角膜散光虽较术后3个月时偏高,但差异均无统计学意义(均为P>0.05).术后3个月试验组、对照组顺规性散光眼数分别是33眼、22眼(P=0.36).结论 可调整缝线的小梁切除术术后1周(可调整缝线拆除前)角膜散光度数明显增加,术后1个月散光度数明显减少,至3个月趋于稳定,术后3个月时角膜散光以顺规性散光为主.  相似文献   

2.
目的 观察不同位置角膜缘切口对Toric ICL后房人工晶状体植入术后角膜散光影响.方法 选择44例(88只眼)高度近视且为顺规性散光患者,随机均分为上方陡轴和颞侧水平角膜缘切口组,表麻下后房人工晶状体植入,IOLmaster测量术前、术后1周、1个月和3个月角膜曲率,观察手术前后角膜散光变化.结果 上方陡轴角膜缘切口组(A组)和颞侧水平角膜缘切口组(B组)术前角膜散光分别为(-2.27±0.80)D和(-2.21±0.84)D(t =0.224,P=0.824),角膜散光陡轴方向平均为(89.6±8.52)°,均为顺规性散光者.术后1周,A组和B组角膜散光分别为(-1.53 ±0.87)D和(-2.77±0.83)D(t =5.059,P=0.000);术后1个月,A组和B组角膜散光分别为(-1.90±0.84)D和(-2.42±0.79)D(t=2.222,P=0.031);术后3个月,A组和B组角膜散光分别为(-1.96±0.76)D和(-2.35±0.78)D(t =1.761,P=0.085).结论 上方陡轴角膜缘切口能一定程度减少顺规性角膜散光,与颞侧水平角膜缘切口相比无明显优势.  相似文献   

3.
目的:研究白内障术中飞秒激光弧形角膜切开术(FSAK)矫正术前角膜散光的临床疗效。方法:回顾性病例对照研究。连续纳入北京爱尔英智眼科医院2017年3月至2021年12月术前规则角膜散光为0.75~2.00 D且接受飞秒激光辅助白内障手术的患者89例(89眼)。所有患者按照术前角膜散光轴位分为顺规散光组(90°±30°)、逆规散光组(180°±30°)及斜轴散光组(45°±15°、135°±15°)。飞秒激光辅助白内障手术及弧形角膜切开术使用Lensx平台。观察患者总体和顺规、逆规散光组术前及术后3个月角膜散光的变化及分布情况。使用配对样本t检验或Wilcoxon符号秩检验比较总体及各亚组术前、术后的散光差异;使用独立样本t检验或Mann-Whitney U检验比较顺规散光组及逆规散光组的差异;散光变化的分析采用Alpins矢量分析法。结果:纳入的89例(89眼)患者中,顺规散光组38例,逆规散光组44例,斜轴散光组7例。所有患者角膜水平径为(11.48±0.57)mm,垂直径为(10.66±0.60)mm。患者总体术后裸眼远视力、最佳矫正远视力相比术前有显著改善(Z=8.01、-7.49,P<0.001)。总体术前角膜散光为(1.28±0.33)D,术后3个月残余散光(0.67±0.37)D,散光矫正量为(0.61±0.33)D。顺规及逆规散光组角膜散光矫正量分别为(0.48±0.27)D、(0.74±0.34)D。总体及顺规、逆规散光组术后平坦轴角膜曲率均有明显升高,而陡峭轴角膜曲率则出现明显下降。矢量分析法显示总体散光矫正指数为0.63±0.30,平坦指数为0.58±0.30,成功指数为0.51±0.25,误差角为-1.83°±12.59°。逆规散光组矫正效果最佳,矫正指数为0.81±0.25,平坦指数为 0.75±0.26,成功指数为0.40±0.24;顺规散光组次之,矫正指数为0.42±0.21,平坦指数为0.39±0.21,成功指数为0.63±0.21。结论:白内障术中FSAK矫正术前角膜散光具有良好的有效性和安全性,相同的弧形切口设计方式在逆规散光中取得了更好的疗效,角膜直径可能是产生影响的重要因素。  相似文献   

4.
目的 研究白内障患者角膜后表面散光(posterior corneal astigmatism,PA)的分布情况及相关影响因素。方法 回顾性分析2017年1月至8月确诊为老年性白内障的患者174例(190眼),分为角膜前表面散光(anterior corneal astigmatism,AA)组:顺规散光组67例(75眼)、逆规散光组77例(80眼)、斜轴散光组32例(35眼)及总AA组174例(190眼);PA组:顺规散光组23例(23眼)、逆规散光组138例(149眼)、斜轴散光组18例(18眼)及总PA组174例(190眼)。术前通过Pentacam测得患者的角膜曲率、中央角膜厚度(central corneal thickness,CCT)、角膜水平直径(white-to-white,WTW),通过IOL Master测量患者的眼轴(axial length,AL)、前房深度(anterior chamber depth,ACD)。Bland-Altman分析模拟角膜散光值(simulated keratometry,SimK)与总角膜散光的差异;线性回归分析AA与PA的相关性;使用Pearson及Spearman相关分析其他眼内生物参数与PA的相关性。结果 角膜SimK与总角膜散光的散光值及轴位差异均有统计学意义(均为P<0.05)。Bland-Altman显示95%一致性界限分别为-0.70~0.55 D、-63.4°~70.2°。顺规散光组AA与PA呈弱的正相关(r=0.316,P=0.005);逆规散光组PA与WTW呈弱的负相关(r=-0.214,P=0.015);而AL、CCT、ACD均与PA无明显相关性(均为P>0.05)。结论 逆规性PA与WTW有弱的负相关,而PA与AL、ACD、CCT等参数没有相关性,且数值大小稳定。  相似文献   

5.
目的 比较小切口非超声乳化术不同位置的切口对角膜散光的影响.方法 将60例(60只眼)欲行小切口非超声乳化人工晶状体植入术的白内障患者随机分两组各30只眼,A组顺规散光者切口选在上方,逆规散光者切口选在颞侧;B组:切口全部选在上方.均采用距角巩膜缘2mm水平6.5mm的巩膜隧道切口,不缝合.观察术前及术后3个月的视力、角膜散光及手术源性散光的情况.结果 A组、B组手术源性散光分别是:(0.94±0.12)D、(0.98±0.12)D,差异无统计学意义.A组术前和术后3月散光为:(1.24±0.46)D、(0.24±0.26)D;B组为(1.25±0.36)D、(2.54±0.45)D;A组视力≥0.5:26只眼(87%):B组:19只眼(64%),A、B组差异有统计学意义.结论 白内障手术切口选在角膜曲率最大的子午线上.可矫正术前已有散光并获得更好地术后视力.  相似文献   

6.
目的 分析白内障患者手术眼角膜散光的分布以及随年龄的变化情况.方法 测量白内障患者手术眼角膜水平轴和垂直轴的屈光度,计算角膜散光,对散光的分布进行统计分析.结果 4753只眼中,1502(31.6%)只眼无角膜散光;1816(38.2%)只眼角膜散光小于等于0.5D;1336(28.1%)只眼大于0.5D小于等于2.0D;99(2.1%)只眼大于2.0D.平均角膜散光(0.81±0.50)D.随着年龄增大,水平轴的角膜屈光度增加(P<0.05),逆规性散光在角膜散光中所占比例增大(P<0.05).结论 30.1%的白内障手术眼角膜散光在0.5D以上.随着年龄增长水平轴的角膜屈光度增加,角膜散光由顺规性散光向逆规性散光转变.  相似文献   

7.
目的 观察导航系统引导下超声乳化白内障吸除术中在角膜曲率最大子午线上行对向透明角膜切口矫正术前角膜散光的临床疗效.方法 队列研究.选择35例(40眼)术前角膜散光度均大于1.0 D白内障患者为实验组,在表面麻醉下于最大角膜曲率子午线上做2.8 mm对向透明角膜切口;另选27例(30眼)术前角膜散光度均大于1.0 D白内障患者为对照组,在表面麻醉下于最大角膜曲率子午线上做2.8 mm单个透明角膜切口.观察2组术前及术后3个月角膜散光度及平均角膜曲率的变化.根据Jaffe's矢量分析原理计算手术源性角膜散光,采用独立样本t检验与配对t检验进行数据分析.结果 对照组术前及术后3个月角膜散光度分别为(1.84±0.40)D和(1.49±0.36)D,差异有统计学意义(t=7.55,P<0.05).实验组分别为(1.89±0.74)D和(0.71±0.60)D,差异有统计学意义(t=13.93,P<0.05).术后3个月2组角膜散光度相比差异有统计学意义(t=-6.31,P<0.05).2组手术源性散光分别为(0.38±0.18)D和(1.55±0.84)D.对照组术前及术后3个月平均角膜曲率分别为(44.18±1.31)D和(44.14±1.31)D,差异无统计学意义(t=1.21,P>0.05).实验组分别为(44.33±1.51)D和(44.29±1.52)D,差异无统计学意义(t=0.73,P>0.05).结论 超声乳化吸除术中行对向透明角膜切口是一种安全、有效的矫正角膜散光的方法.  相似文献   

8.
目的 探讨同切口青光眼白内障联合手术对角膜源性散光的影响.方法 对30例32只眼青光眼合并白内障患者行同切口白内障囊外摘除人工晶状体植入联合小梁切除手术.采用电脑验光曲率仪测量术前及术后3d、1周、1个月、3个月的角膜曲率的变化.结果 术后3d散光度为(3.09±0.59)D,达最大,以顺规性散光为主,与术前相比,差异有统计学意义(P<0.01).1周后散光度为(1.75±0.58)D仍以顺规性散光为主,与术前相比,差异有统计学意义(P<0.01).3个月时散光度为(0.73±0.22)D,以逆规性散光为主,与术前相比,差异无统计学意义(P>0.05).结论 同切口青白联合手术术后早期可产生较大的散光,但角膜散光度可随时间的延长而逐渐减少,3个月时基本与术前相当.  相似文献   

9.
眼球的散光主要包括角膜散光和眼内散光(即晶状体的散光),角膜散光由角膜前后表面散光组成.角膜后表面散光大小约0.3D,主要为逆规散光(占85%~96.1%).角膜后表面非球面性并非完全由前表面的非球面性决定,它与年龄呈负相关.随年龄增长前表面散光由顺规向逆规漂移明显;后表面散光的趋势则相反,但总体变化很小.同时角膜前后表面半径比与年龄也呈负相关.后表面散光对前表面的补偿作用随年龄增加而减小.因此,对于青年人,后表面散光减小总角膜散光;对于老年人,后表面散光则增加总角膜散光.忽略后表面散光可能会导致总角膜散光的错误估计,测量角膜后表面散光以进一步准确计算角膜总散光是白内障屈光手术临床应用的迫切需求.  相似文献   

10.
Toric人工晶状体(intraocular lens, IOL)植入术因其高度安全性及可预测性已成为白内障术中矫正散光的首选方式。角膜散光包括角膜前表面散光(ACA)和角膜后表面散光(PCA)。既往多根据ACA估测角膜散光, 会导致一些顺规散光眼的过矫及逆规散光眼的欠矫。PCA对总角膜散光(TCA)的影响不可忽视。IOL Master、Lenstar 900在角膜曲率测量方面有高度预测性与可重复性。可直接测量全角膜曲率的设备理论上更准确。模拟角膜曲率(SimK)散光与TCA一致性良好的情况下, 可直接使用Barrett Toric公式搭配IOL Master或Lenstar的SimK;两者一致性差的情况下的选择仍有争议。若PCA≥0.8 D, 推荐使用实测的PCA。目前, 眼科医生应根据不同设备的测量结果, 结合患者自身情况, 做到个性化选择及搭配, 尽最大可能减少患者术后的残余散光。(国际眼科纵览, 2022, 46:437-442)  相似文献   

11.
Bozkurt B  Irkec M  Gedik S  Orhan M  Erdener U 《Cornea》2002,21(5):458-462
PURPOSE: To evaluate the corneal topography in patients with tilted-disc syndrome to determine the relationship between optic disc dysversion and corneal astigmatism and the pattern of astigmatism in these patients. METHODS: The study included 23 eyes of the 13 tilted-disc syndrome patients with spheric refractive errors ranging between +1.00 D and -9.00 D (mean -4.00 +/- 3.4 D) and astigmatic errors ranging between -0.50 and -4.50 D (mean -1.95 +/- 0.93 D). Corneal topography was performed by computer-assisted videokeratoscope topographic modelling system 2 (TMS-2) and incidence of corneal astigmatism, corneal topographic patterns, and mean values of the topographic indices were determined. RESULTS: Corneal topographic analysis showed corneal astigmatism in 22 out of 23 patients with tilted discs. Corneal astigmatism was symmetric bow tie pattern in 10 eyes (45.45%), asymmetric bow tie pattern in 11 eyes (50%) and irregular in 1 eye (4.5%). Among the patients with bow tie pattern group (21 eyes), 14 eyes had with-the-rule astigmatism, 1 eye had against-the-rule astigmatism, and 6 eyes had oblique astigmatism. In 18 eyes, astigmatism was corneal, whereas combined corneal and lenticular in 4 eyes and lenticular in 1 eye. CONCLUSION: In the majority of tilted-disc cases, ocular astigmatism is mainly corneal. Morphogenetic factors in the development of the tilted disc might possibly influence the corneal development in such a way to result in corneal astigmatism.  相似文献   

12.
目的 评估飞秒激光联合对称弧形角膜切口对白内障合并角膜散光患者的治疗效果。方法 前瞻性研究。收集43例(57眼)白内障合并≥0.75 D角膜规则散光的患者,均行飞秒激光超声乳化白内障手术,术中同时采用对称弧形角膜切口矫正角膜散光。弧形切口设置在角膜直径中央8.0 mm处,深度为角膜厚度的85%,术中开口器分离弧形切口。术前及术后均采用Pentacam三维眼前节分析系统记录角膜散光。采用Alpins矢量法分析术后角膜散光变化,并分析散光类型、年龄与散光矫正效果的相关性。结果 术中及术后所有患者均未出现角膜穿透、上皮损伤、角膜上皮增生、切口感染等并发症。术前患眼角膜散光为(1.23±0.31)D,术后3个月患眼角膜散光下降到(0.85±0.34)D,差异有统计学意义(t=4.645,P=0.000)。对患者手术前后角膜散光的变化进行矢量分析,结果显示,目标诱导散光为0.80~2.10(1.23±0.31)D,手术诱导散光为0.00~1.80(0.68±0.45)D,差异向量为0.26~1.70(0.89±0.42)D,矫正指数为0.00~1.01(0.55±0.27),理想值为1,提示总体...  相似文献   

13.
陈宏民 《国际眼科杂志》2011,11(7):1267-1268
目的:比较小切口非超声乳化术不同位置的切口对角膜散光的影响。方法:将80例80眼白内障患者随机分两组各40眼,A组:顺规散光者切口选在上方,逆规散光者切口选在颞侧;B组:切口全部选在上方。均采用距角膜缘2mm反眉形6.0mm的巩膜隧道切口,不缝合。观察术前及术后3mo的视力、角膜散光。结果:A组术前和术后3mo的散光位为1.15±0.53D,0.89±0.50D,B组为1.13±0.57D,1.64±0.68D。A组视力≥0.5者34眼(85%),B组:24眼(60%),A,B组差异有统计学意义。结论:白内障手术切口选在角膜曲率最大的子午线上,可矫正术前已有散光并获得更好的术后视力。  相似文献   

14.
国人近视人群角膜前表面散光与眼球散光的定量分析   总被引:1,自引:0,他引:1  
目的:研究国人近视人群角膜前表面散光与眼球散光的关系,为眼屈光手术设计提供参考。方法:连续性资料358眼。采用日本TOMEY公司的TMS-4角膜地形图仪进行角膜前表面地形图检查,获取角膜前表面散光度数及轴向;用日本TOPCON公司的RM8000自动电脑验光仪进行散瞳验光,获取眼球散光度数和轴向。结果:眼球散光与角膜前表面散光的比值为0.811±0.665;眼球散光<0.50D者150眼,散光度数差异、散光轴向差异均有统计学意义;散光度数、散光轴向均正相关;0.50D≤眼球散光<1.00D者122眼,散光度数差异有统计学意义;轴向差异无统计学意义;散光度数无相关性,散光轴向正相关;眼球散光≥1.00D者86眼,散光度数差异无统计学意义;散光轴向差异有统计学意义;散光度数、散光轴向均正相关。结论:角膜后表面及晶状体对角膜前表面散光有一定的补偿作用;角膜前表面散光与眼球散光正相关,散光度数越高,相关程度越高;角膜屈光手术根据眼球散光进行手术设计可能较好,屈光性晶状体置换术及白内障手术可根据角膜前表面散光确定手术切口位置。  相似文献   

15.
目的 超声乳化白内障吸出联合人工晶状体植入术与可植入式角膜接触镜(implantable collamer lens,ICL)植入术后角膜曲率及散光的变化,并进行比较,为屈光性白内障手术视觉质量的提高提供理论指导。方法 收集我院行超声乳化白内障吸出联合人工晶状体植入术的患者34例(52眼)为A组,同期行ICL植入术的患者26例(52眼)为B组,两组患者手术前后使用Pentacam眼前节分析系统检测角膜前后表面曲率、角膜散光。比较两组患者术前和术后3个月的角膜前表面曲率、角膜后表面曲率、角膜前表面散光、角膜后表面散光及角膜总屈光力与总散光,比较两组患者手术前后各数值变化值的差异。结果 A组患者手术前后角膜前表面曲率及散光差异均无统计学意义(P=0.734、0.427),角膜后表面曲率、角膜后表面散光差异均有统计学意义(P=0.022、0.000)。B组患者手术前后角膜前表面曲率及前表面散光差异均无统计学意义(P=0.475、0.446),角膜后表面曲率及后表面散光差异均有统计学意义(P<0.001,P=0.016)。A组与B组患者手术前后角膜前表面曲率差值、角膜前表面散光差值差异均无统计学意义(P=0.534、0.841)。A组患者手术前后角膜后表面曲率差值、角膜后表面散光差值均大于B组,差异均有统计学意义(P=0.001、0.022)。A组与B组手术前后角膜总散光差异有统计学意义(P<0.05)。结论 白内障超声乳化术与ICL植入术对角膜前表面曲率及前表面散光的影响较小,但是对角膜后表面曲率及后表面散光的影响较大,且白内障超声乳化术较ICL植入术对角膜后表面曲率及后表面散光的影响更大。  相似文献   

16.
AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens (IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes. METHODS: This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters (D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL (ART2) or AcrySof IQ ReSTOR IOL (ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function (aMTF), Strehl ratio (SR), spectacle independence, and patient satisfaction between groups. RESULTS: Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were -0.18±0.07 D and -0.91±0.25 D in groups ART2 and ReSTOR (P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively; these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively (P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results. CONCLUSION: ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.  相似文献   

17.
目的:探讨儿童眼总散光与角膜散光、眼内散光的线性关系。方法:系列病例研究。选取2018年 6─12月在连云港市妇幼保健院行睫状肌麻痹验光且散光度≥1.00 D的3~6岁儿童,按入选标准选 取76例(126眼),收集睫状肌麻痹后角膜散光度及轴位、眼总散光度及轴位4组数据。运用矢量的 平行四边形法则及三角函数公式分析并计算眼内散光度及轴向,对总散光度与角膜散光度、眼内 散光度做多重线性回归分析。结果:眼总散光度与角膜散光度、眼内散光度遵循Ctotal=0.004+0.988 ×Ccorneal+0.928×Cintraocular(R2 =0.998,P<0.001)。眼总散光轴向与角膜散光轴向、眼内散光轴向遵循 Atotal=48.391+0.708×Acorneal-0.185×Aintraocular(R2 =0.531,P<0.001)。126只散光眼的眼内散光中远视性 散光92眼(73.0%),散光度最小值+0.25 D,最大值+2.00 D,平均(+0.58±0.29)D;近视性散光34眼 (27.0%),散光度最小值-0.03 D,最大值-1.03 D,平均(-0.26±0.24)D。结论:眼总散光度与角膜 散光度、眼内散光度呈高度线性相关。可通过公式Ctotal=0.004+0.988×Ccorneal+0.928×Cintraocular反推计 算出眼内散光度,且准确性高。大部分眼内散光对角膜散光起补偿抵消作用,对角膜散光轴向影响小, 眼内散光以逆规散光为主。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号