首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.

Purpose

We evaluated with magnetic resonance imaging (MRI) the degradation and osteointegration features of a new type of bioabsorbable interference (BioRCI) screw composed of poly-L-lactic acid and hydroxyapatite (PLLA-HA) used for tibial graft fixation in anterior cruciate ligament (ACL) reconstruction.

Materials and methods

Thirty-one patients underwent arthroscopic surgery for ACL reconstruction using doubled gracilis and semitendinosus tendons fixed to the tibial tunnel with PLLA-HA (BioRCI-HA) screws. Two groups of patients were evaluated, one group 10–13 months after surgery and the other after 30–40 months. The standard knee ligament evaluation form of the International Knee Documentation Committee (IKDC) was used for clinical assessment and MRI for the radiological assessment.

Results

MRI after 10–13 months revealed findings referable to healing and integration of the bone-graft-screw system, findings that disappeared at later follow-up examinations. The BioRCI-HA screw remained constantly visible in all patients, although with changes in signal intensity over time.

Conclusions

BioRCI-HA screws allow adequate primary stability and superior osteoconduction and biocompatibility in comparison with plain PLLA screws. The absence of ferromagnetic artefacts allows accurate MRI follow-up and adequate evaluation of ligament synovialisation, screw degradation and graft osteointegration.  相似文献   

2.
BACKGROUND: During the past decade, bioabsorbable interference screws have become increasingly popular in endoscopic reconstructions of the anterior cruciate ligament. With these screws, there is no need for a second operation for removal and no complicating factor if later revision surgery is necessary. Several pullout studies have found similar results between metal and bioabsorbable interference screws; however, few studies have investigated the clinical outcome. HYPOTHESIS: There is no difference in the clinical outcome of bioabsorbable interference screws compared with metal screws. STUDY DESIGN: Randomized controlled clinical trial; Level of evidence, 1. METHODS: Forty-one patients were randomized for the use of either metal interference screws (20 patients) or bioabsorbable poly-l-lactic acid screws (21 patients). The patients were followed with clinical examinations at 6, 12, and 24 weeks and at 1 and 2 years postoperatively. RESULTS: Subjective knee function was better in the patients in the metal screw group; they had less pain at rest, a higher Tegner score, a higher Lysholm score, and better subjective knee function at 2 years compared to the bioabsorbable screw group. However, there was no difference in stability between the groups.Conclusion and CLINICAL RELEVANCE: Because of the inferior results in the bioabsorbable screw group in our study, and until larger studies show otherwise, we do not find the advantages of using bioabsorbable screws sufficient to warrant the routine use of poly-L-lactic acid screws in anterior cruciate ligament reconstructions.  相似文献   

3.
PURPOSE: To examine at magnetic resonance (MR) imaging the degradation of an interference screw made of polyglycolic acid (67.5%) and trimethylene carbonate (32.5%) and compare the MR findings with the clinical evaluation results. MATERIALS AND METHODS: Clinical and MR imaging studies were performed concomitantly 6 months (in 20 patients), 1 year (in 10 patients), and 2 years (in eight patients) after surgery. Screw resorption rate, tibial tunnel appearance and contents, epiphyseal reaction, reconstructed ligament appearance, bone plug healing, joint effusion, and synovitis were evaluated. RESULTS: The screw was observed to be partially resorbed (by approximately one-third) at 6 months and totally resorbed at 1 year. Enhancement of the tunnel content, which can be linked to bone healing and screw replacement, was seen without a surrounding inflammatory reaction. Bone tunnel enlargement was observed and remained stable over time; this phenomenon has often been reported with metallic or polylactic acid interference screws and could be due to the position of the screw within the tunnel. The tissue that was seen at MR imaging to be replacing the screw was either fibrous or fatty and fibrous but never bone. CONCLUSION: Resorption of the screw does not appear to be related to clinical results.  相似文献   

4.
PURPOSE: Anterior cruciate ligament (ACL) reconstructive surgery has seen significant progress since bioabsorbable interference screws have replaced synthetic metallic screws for ligament graft fixation within the femoral and tibial osseous tunnel. Our study compared the MR images of patients who underwent ACL reconstruction using bioabsorbable interference screws with those of patients who underwent ACL reconstruction using metallic screws to evaluate the MR aspects of degradation and osteointegration processes of bioabsorbable interference screws post-operatively. MATERIALS AND METHODS: Between September 1999 and December 2002 we performed MRI on 40 patients who underwent arthroscopic ACL reconstruction with patellar tendon auto-graft using PDLLA bioabsorbable screws in 35 cases and metallic screws in 5 cases. After surgery, all patients underwent an intensive rehabilitation programme along with clinical evaluation using the standard knee ligament evaluation form of the International Knee Documentation Committee (IKDC) and radiological examinations. MR studies were performed 1, 2 and 3 years post-operatively using a 0.5-Tesla MR scanner with T1- and T2*-weighted and STIR sequences. RESULTS: Thirty-three patients were clinically classified as group A IKDC (full return to sports activity) and 7 patients as group B IKDC. No foreign-body reaction was found in patients treated with bioabsorbable interference screws, both from a clinical point of view and from laboratory exams. Ferromagnetic artefacts were found in all patients treated with metallic interference screws. In patients with bioabsorbable interference screws, degradation of the screws and absence of significant artefacts allowed correct evaluation of the signal of the reconstructed ligament throughout its length, the osseous tunnels and the joint cavity. In 34 of 35 patients with bioabsorbable interference screws, the screw could not be detected due to complete degradation. In 8, 12 and 4 cases, a small cyst-like formation due to screw hydrolysis was present at the screw site within 1, 2 and 3 years from surgery respectively. Only in 4 cases was the process of osteointegration of the screw and bone plug complete 3 years after the operation, with consequent restoration of bone morphology. DISCUSSION AND CONCLUSIONS: The use of bioabsorbable interference screws is a valuable alternative to synthetic metallic fixation implants as the absence of artefacts allows correct post-operative MR follow-up. MRI is the only technique able to visualize all the portions of the transplant and to evaluate the healing process. Bioabsorbable interference screws usually degrade within one year. However, full osteointegration requires a long time and may not be complete 3 years after surgery. The presence of cyst-like formations at the screw site has to be regarded as a normal feature of the screw degradation process. Therefore, the use of bioabsorbable interference screws is recommended as it enables MR follow-up of the knee after ACL reconstruction.  相似文献   

5.
Bioabsorbable interference screws are commonly used to secure the graft during anterior cruciate ligament (ACL) reconstruction, in part because they result in less image degradation on subsequent magnetic resonance imaging (MRI). However, some bioabsorbable screws are associated with abnormalities on MRI examination not reported with metallic interference screws. We describe a finding on knee MRI examination after ACL reconstruction using a polylactide carbonate (PLC) bioabsorbable screw that we believe to be previously unreported with any other bioabsorbable screws. The finding raised suspicion of hemorrhage or infection, neither of which were present clinically. Analysis of tissue from the tibial tunnel suggested an explanation for the MRI finding: calcite crystals. An additional five patients with knee MRI examinations after ACL reconstruction using a PLC screw were reviewed and correlated with clinical findings with four having similar imaging abnormalities present. The PLC (Calaxo screw, Smith and Nephew, Andover, MA) screw used in these patients has been recalled in the United States and Europe by the manufacturer after a greater than expected incidence of adverse reactions, and legal action may be pending.  相似文献   

6.
We report a prospective series of 101 patients receiving a four-strand semitendinosus-gracilis autograft for anterior cruciate ligament reconstruction using a new bicortical tibial fixation technique with bioabsorbable interference screws. Patients (average age 32 years) were operated on between November 1997 and Mai 1998, and follow-up was at least 12 months postoperatively. The evaluation consisted of history, clinical examination, IKDC score, Cincinnati Knee Score, KT-1000 testing, standardized radiography and magnetic resonance imaging. One hundred patients were available for follow-up. There were two traumatic reruptures 6 and 11 months postoperatively. By IKDC score 87 patients were in groups A and B, 12 in group C, and 2 with a rerupture in group D. Mean Cincinnati Knee Score was 82 (range 46–100), KT-1000 manual maximum at follow-up showed an average difference of 1.7 mm between the sides. Full extension was rapidly achieved in all cases, and flexion averaged 135°. Considering the enlargement caused by the bioabsorbable interference screws, the incidence of tunnel widening was 6.6% on the femoral side and 1.7% on the tibial side. Tunnel widening did not affect the clinical results. Three patients experienced an effusion after more than 6 months postoperatively. There was one infection, which settled without functional impairment after early arthroscopic lavage and intravenous antibiotics. Otherwise no complications occurred. The described technique for anterior cruciate ligament reconstruction combines the advantage of anatomical graft position with sufficient graft fixation. A short intra-articular graft construct with a strong tendon to bone interface was created. Clinically, 87% of patients had a normal or nearly normal IKDC score at follow-up. Magnetic resonance imaging revealed a considerable increase in tunnel area caused by the insertion of the interference screws. On the other hand, the development of a “fibrous interzone” between the graft and the bone tunnel was prevented in most cases. At short-term follow-up the bicortical tibial fixation proved to be efficient even with an aggressive rehabilitation program. Received: 26 November 1999 Accepted: 5 March 2000  相似文献   

7.
We report a case of subcutaneous pretibial ganglion, with direct communication to the tibial tunnel after an autologous reconstruction of the anterior cruciate ligament with hamstring tendons. The tibial graft fixation was with a 9 mm poly-L-lactide interference screw 5 years earlier. The screw had undergone complete resorption at the time the cyst occurred. No joint inflammatory reaction or graft insufficiency was detected. The patient underwent cyst excision and curettage of the tibial tunnel with full recovery. This complication seems to be the consequence of a direct communication between the joint and the pretibial subcutaneous tissue through a fibrous tibial tunnel and would have occurred, as there is no full osteointegration of the graft due to the resorption of the bioabsorbable interference screw.  相似文献   

8.
BACKGROUND: Female patients undergoing arthroscopic anterior cruciate ligament reconstruction with a hamstring tendon graft developed increased postoperative laxity compared to male and female patients who had reconstruction using a patellar tendon graft. This difference may be due to graft slippage in less dense female tibial bone. HYPOTHESIS: Reinforcement of tibial fixation of the hamstring tendon graft in women by supplementary methods may reduce laxity. STUDY DESIGN: Randomized controlled clinical trial; Level of evidence, 2. METHODS: Fifty-six female patients divided into 2 groups (standard tibial fixation with 7 x 25-mm metal interference screw versus metal interference screw with supplementary staple fixation) were followed for 2 years. RESULTS: After 2 years, the mean side-to-side difference using KT-1000 arthrometer manual maximum measurements was 1.8 mm (standard group) and 1.1 mm (staple group) (P=.05). The percentage of patients with a side-to-side difference of <3 mm did not differ significantly between the 2 groups (P=.66): 88.8% of the standard group versus 90.5% of the staple group. A grade 0 Lachman test result was present in 63% of the standard group and 86% of the staple group (P=.04). Kneeling pain was experienced by 7% of the standard group and 29% of the staple group (P=.05). CONCLUSIONS: Supplementary tibial fixation in female patients undergoing anterior cruciate ligament reconstruction with hamstring tendon graft in addition to a single-size screw significantly improves laxity measurements and clinical stability assessment 2 years after surgery. However, this improvement is at the cost of increased kneeling pain.  相似文献   

9.
BACKGROUND: The literature provides little biomechanical data about femoral fixation of hamstring grafts in posterior cruciate ligament reconstruction. HYPOTHESIS: A hybrid fixation technique with use of an undersized screw has sufficient strength to provide secure fixation of posterior cruciate ligament grafts. Additional aperture fixation with a biodegradable interference screw can prevent graft damage that might be caused by an acute angle on the edge of the femoral tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: In part 1, extracortical fixation of posterior cruciate ligament reconstructions with quadrupled porcine flexor digitorum grafts to simulate human hamstring grafts was compared with hybrid fixation methods using 6-, 7-, and 8-mm screws. Groups were tested in cycling loading with the load applied in line with the bone tunnel. In part 2, extracortical fixation was compared with hybrid fixation using a 1-mm undersized screw anterior and posterior to the graft. Structural properties and graft abrasion were evaluated after cyclic loading with the load applied at 90 degrees to the tunnel. In each group, 8 porcine knees were tested. RESULTS: In part 1, stiffness, maximum load, and yield load were significantly higher for hybrid fixation than for extracortical fixation. Hybrid fixation with an 8-mm screw resulted in higher yield load than with a 7-mm screw. In part 2, graft laceration was more pronounced in specimens with extracortical fixation than with hybrid fixation. Posterior screw placement was superior to the anterior position. CONCLUSION: For all parameters, hybrid fixation with an interference screw provided superior structural results. No relevant disadvantages of undersized screws could be found. Graft damage due to abrasion at the edge of the femoral bone tunnel was reduced by use of an interference screw. The posterior screw placement seems favorable. CLINICAL RELEVANCE: Hybrid fixation of hamstring grafts in posterior cruciate ligament reconstruction is superior to extracortical fixation alone with no relevant disadvantages of undersized screws. The results raise the suspicion of an acute angle effect of the femoral bone tunnel.  相似文献   

10.
PURPOSE: Anterior cruciate ligament reconstructions are becoming increasingly frequent, and MRI has been shown to be the best imaging modality for the non-invasive assessment of surgical outcome. Use of the quadriceps tendon as a biological replacement for injured cruciate ligament is a recent innovation. This study evaluated by MRI the results of anterior cruciate reconstruction in 27 consecutive patients who underwent arthroscopic reconstruction with homologous quadriceps tendon. MATERIAL AND METHODS: MRI was carried out on 27 patients who had undergone anterior cruciate ligament reconstruction with the middle third of the homolateral quadriceps tendon. The examinations were performed on two MRI units: a permanent 0.2-Tesla dedicated magnet (Artoscan, Esaote Italy) and whole-body 1.5-Tesla superconducting magnet (Signa, GE Medical Systems Milwaukee, Winsconsin USA). Axial, sagittal and coronal images were acquired with SE, GE and STIR fat suppression sequences. The examinations were performed 1, 3, and 6 months post-operatively in 16 patients, and 1 and 3 post-operatively in 11 patients. The same arthroscopic surgical technique was employed in all patients, with 20 cases of tibial mono-tunnel femoral semi-tunnel, and 7 cases with tibial bi-tunnel technique. All patients were assessed by arthrometric and clinical tests after surgery. Bioabsorbable interference screws were used for tibial fixation in all patients and metallic interference screws were used for femoral graft fixation in 8 patients. RESULTS: In all cases MRI correctly visualised the tunnel positions, the articular portion and the bone-portion of the graft inside the tibial and femoral tunnels. The absence of paramagnetic artefacts in the tibia allowed complete visualisation on the axial, sagittal and coronal MRI images with optimal spatial and contrast resolutions. In 6 cases, the presence of metal residues from the surgical cutter prevented correct evaluation of femoral tunnel content. No new graft or articular lesions were found. In 18/27 cases peri-focal marrow edema around the tibial tunnel had disappeared 3 months after surgery. The process of synovial incorporation was judged to be correct in all cases. DISCUSSION: The use of anterior cruciate ligament reconstruction with the quadriceps tendon is a important innovation given the size of the harvested material and the possibility of completely filling the osseous tunnels, without interposition of synovial proliferation or fluid collection between tendon and bone, as confirmed by MRI. Furthermore, the use of non-metallic screws allows MRI evaluation of tunnel content and oedema in the spongy bone around the tunnel. The study of the double tibial tunnel requires specific obliqueness in the coronal plane scans. CONCLUSIONS: This arthroscopic technique for anterior cruciate ligament reconstruction allows thorough MRI evaluation of all portions of the transplant, and in particular those coursing within the tibia and femur. The absence of bone oedema around the tunnels and synovial proliferation within the tunnels may be predictive of faster healing and complete bone incorporation of the grafts.  相似文献   

11.
The aim of this study was to look at the clinical outcome of polylactide carbonate (PLC) interference screws in knee ligament reconstruction surgery. We prospectively followed up 59 patients who underwent primary hamstring anterior cruciate ligament (ACL) reconstructions using PLC (Calaxo screw; Smith and Nephew, Andover, MA) screws to secure the graft in the tibial tunnel. The average age was 34 years (range 17–55 years, SD 8.93). Twenty-three (39%) patients presented with complications [synovitis in 15% (nine) patients, prominent tibial swelling in 34% (20) patients and both in seven patients]. In comparison, similar complications were not seen in two groups of 59 age and sex matched patients in whom PLLA (Bio RCI; Smith and Nephew, Andover, MA) screws or Titanium (RCI; Smith and Nephew, Andover, MA) screws were used by the same surgeon. The problems encountered in the PLC screw group did not adversely affect knee stability. Six patients underwent exploration of the tibial tunnel site. A sterile white cheesy substance was removed, leaving an empty tibial tunnel. The ACL graft was found to be well attached to tibial tunnel in all cases. The PLC screw diameter, surface area or tibial tunnel diameter did not have any correlation to the occurrence of complications. Two patients required multiple washouts, one of whom developed a deep infection. The degradation of PLC screws does not follow the gradual and controlled pattern demonstrated in the ovine model. The unpredictable screw degradation, and the reaction to it can lead to serious clinical consequences.  相似文献   

12.
We used a standardized model of calf tibial bone to investigate the influence of screw diameter and length on interference fit fixation of a three-stranded semitendinosus tendon graft for anterior cruciate ligament reconstruction. Biodegradable poly-(L-lactide) interference screws with a diameter of 7, 8, and 9 mm and a length of 23 and 28 mm were used. We examined results in three groups of 10 specimens each: group 1, screw diameter equaled graft diameter and screw length was 23 mm; group 2, screw diameter equaled graft diameter plus 1 mm and screw length was 23 mm; group 3, screw diameter equaled graft diameter and screw length was 28 mm. The mean pull-out forces in groups 1, 2, and 3 were 367.2+/-78 N, 479.1+/-111.1 N, and 537.4+/-139.1 N, respectively. The force data from groups 2 and 3 were significantly higher than those from group 1. These results indicate that screw geometry has a significant influence on hamstring tendon interference fit fixation. Increasing screw length improves fixation strength more than oversizing the screw diameter. This is important, especially for increasing tibial fixation strength because the tibial graft fixation site has been considered to be the weak link of such a reconstruction.  相似文献   

13.
Initial tibial fixation strength is the weak link after anterior cruciate ligament reconstruction with a quadrupled hamstring tendon graft fixed with bioabsorbable interference screws. The purpose of this study was to determine the biomechanical differences between 28-mm and tapered 35-mm interference screws for tibial fixation of a soft tissue graft in 16 young cadaveric tibias. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine aligned with the tibial tunnel to simulate a worst-case scenario. The mode of failure was graft slippage past the screw in all but one of the specimens. The mean maximum load at failure of the 28-mm screw was 594.9 +/- 141.0 N, with mean displacement at failure of 10.97 +/- 2.20 mm. The mean maximum load at failure of the 35-mm screw was 824.9 +/- 124.3 N, with a mean displacement to failure of 14.38 +/- 2.15 mm. The 38% difference in mean maximal load at failure was significant. Important variables in hamstring tendon graft fixation within a bone tunnel include bone mineral density, dilatation, gap size, screw placement, and screw width and length. Attention to these variables will help to provide secure graft fixation during biologic incorporation throughout the rehabilitation period.  相似文献   

14.
Poly-l-lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29-year-old female patient with a failure of a biodegradable interference screw at 22 months after ACL reconstruction using bone–patellar tendon–bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990–2005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.  相似文献   

15.
Poly–L–lactic acid (PLLA) bioabsorbable interference screws are widely used for fixation of tendon to bone and bone to bone in anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) reconstructions. Complications are rare. To our knowledge this is the first report of severe chondral damage caused by late breakage of the screw. Breakage of bioscrews has only been published in cases with tendon to bone fixation.  相似文献   

16.
The endoscopic single incision technique for anterior cruciate ligament (ACL) reconstruction with a femoral half-tunnel may lead to a graft/tunnel mismatch and subsequent protrusion of the block from the tibial tunnel. The typical tibial fixation with an interference screw is not possible in these cases. Fixation with staples in a bony groove inferior to the tunnel outlet can be used as an alternative technique. Current literature does not provide biomechanical data of either fixation technique in a human model. This study was performed to evaluate the primary biomechanical parameters of this technique compared with a standard interference screw fixation of the block. Fifty-five fresh-frozen relatively young (mean age 44 years) human cadaver knee joints were used. Grafts were harvested from the patellar tendon midportion with bone blocks of 25 mm length and 9 mm width. A 10-mm tibial tunnel was drilled from the anteromedial cortex to the center of the tibial insertion of the ACL. Three different sizes of interference screws (7 × 30, 9 × 20, 9 × 30 mm) were chosen as a standard control procedure (n = 40). For tibial bone-block fixation the graft was placed through the tunnel, and the screw was then inserted on the cancellous or the cortical surface, respectively. Fifteen knees were treated by staple fixation. A groove was created inferior to the tunnel outlet with a chisel. The bone block was fixed in this groove with two barbed stainless steel staples. Tensile testing in both groups was carried out under an axial load parallel to the tibial tunnel in a Zwick testing machine with a velocity of 1 mm/s. Dislocation of the graft and stiffness were calculated at 175 N load. Maximum load to failure using interference screws varied between 506 and 758 N. Load to failure using staples was 588 N. Dislocation of the graft ranged between 3.8 and 4.7 mm for interference screw fixation and was 4.7 mm for staples. Stiffness calculated at 175 N load was significantly higher in staple fixation. With either fixation technique, the recorded failure loads were sufficient to withstand the graft loads which are to be expected during the rehabilitation period. Staple fixation of the bone block outside of the tunnel resulted in a fixation strength comparable to interference screw fixation. Received: 2 September 1996 Accepted: 30 January 1997  相似文献   

17.
可吸收螺钉治疗后交叉韧带胫骨附着部撕脱骨折   总被引:4,自引:0,他引:4  
目的:利用可吸收螺钉治疗后交叉韧带胫骨附着部撕脱骨折的固定,避免二次手术创伤.方法:早期行切开复位可吸收螺钉内固定,术前,手术当天及术后定期摄X片.结果:平均随诊14个月,己随诊患者伤肢局部功能情况和影像学检查结果综合评价标准,早期手术疗效优34例,可2例.结论:可吸收螺钉治疗后交叉韧带胫骨附着部撕脱骨折可达到早期固定可靠,避免二次手术创伤,是一种较好的选择.  相似文献   

18.
BACKGROUND: Interference screw fixation of the graft in anterior cruciate ligament reconstruction is considered the gold standard, but limited clinical experience suggests that transcondylar fixation is equally effective. PURPOSE: To compare transcondylar and interference screw fixation. STUDY DESIGN: Ex vivo biomechanical study. METHODS: Twenty pairs of unembalmed knees underwent anterior cruciate ligament reconstruction with patellar tendon autografts. In 1 knee of each pair, the bone plug was stabilized in the femoral tunnel with standard interference screws; in the other knee, transcondylar screws were used. Testing to failure occurred immediately or after 1000 cycles of sinusoidal loading (30 to 150 N) (20 paired reconstructions each). Fixation stiffness, strength, graft creep, displacement amplitude, and change in amplitude were measured and compared (repeated measures anaylsis of variance with Tukey test; P <.05). RESULTS: There was no significant difference in acute strength, maximum load within 3 mm, or stiffness between transcondylar fixation (410 +/- 164 N, 183 +/- 93 N, and 49.6 +/- 28 N/mm, respectively) and interference fixation (497 +/- 216 N, 206 +/- 115 N, and 61 +/- 37.8 N/mm, respectively). Similarly, there was no significant difference in cyclic strength, maximum load within 3 mm, or stiffness between transcondylar fixation (496 +/- 214 N, 357 +/- 82.9 N, and 110 +/- 27.4 N/mm, respectively) and interference fixation (552 +/- 233 N, 357 +/- 76.2 N, and 112 +/- 26.8 N/mm, respectively). Predominant modes of failure were bone plug pullout (transcondylar fixation) and tendon failure or bone plug fracture (interference fixation). CONCLUSIONS: Transcondylar screw fixation of the patellar tendon autograft into the femoral tunnel performed mechanically as well as interference screw fixation. CLINICAL RELEVANCE: The results suggest that transcondylar and interference screws provide similar fixation for anterior cruciate ligament reconstruction.  相似文献   

19.
BACKGROUND: Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS: There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: Forty-eight anterior cruciate ligament reconstructions were performed using immature porcine femurs stripped of soft tissue and doubled-over porcine flexor digitorum profundus tendon grafts. Specimens were randomized to bioabsorbable or titanium interference screw fixation. Specimens were randomized to one of three pull angles (0 degrees , 30 degrees , 60 degrees ) representing loading at different knee flexion angles (n = 8/group). Reconstructed ligaments were tensioned to 10 N followed by 200 loading cycles between 10 and 150 N and a final failure test. Construct elongation (mm) at 100 and 200 cycles and failure load (N) were analyzed using a 2-way analysis of variance (P < .05). RESULTS: Screw material interacted significantly with graft tension angle, as the bioabsorbable screw specimens demonstrated significantly greater fixation strength when tensioned at greater angles. Specimens fixed with bioabsorbable screws showed significantly less elongation at both 100 and 200 cycles and significantly greater failure load compared with titanium screws. CONCLUSION: Bioabsorbable interference screws acutely have increased fixation strength compared with titanium interference screws for anterior cruciate ligament grafts loaded at greater tension angles. CLINICAL RELEVANCE: The strength of anterior cruciate ligament reconstruction fixation increases with increasing divergence between the tension angle and femoral tunnel, a condition seen when the knee approaches full extension.  相似文献   

20.
Developing bio-absorbable interference screws for anterior cruciate ligament (ACL) reconstruction has proven to be a challenging task. The aim of this study was to investigate the osteogenetic response of poly-lactide carbonate (PLC) interference screws in ACL reconstruction in humans. Ten patients (median age, 28 years) underwent arthroscopic ACL reconstruction with semitendinosus/gracilis tendon graft and a PLC interference screw. The patients were scanned with a multi-slice CT scanner 2 weeks and 1 year postoperatively. Fourteen days postoperatively a mean tunnel widening of 78% [52%; 110%] was observed. At 1-year follow-up, the mean tunnel widening was 128% [84%; 180%]. No sign of bone replacement or bone ingrowth was observed. Factors such as accelerated rehabilitation, micro-motions, and early screw degradation might be responsible for this large tunnel widening. Our results demonstrate the difficulty in translation of preclinical data. This study illustrates the need for extensive preclinical investigation of new materials for clinical purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号