1.
An ESTRO booklet and a report of the Netherlands Commission on Radiation Dosimetry have been published recently describing empirical methods for monitor unit (MU) calculations in symmetrical high-energy photon beams. Both documents support the same basic ideas; firstly the separation of head scatter and volume scatter components and secondly the determination of head scatter quantities in a mini-phantom. Based on these ideas the methods previously described for MU calculations in symmetrical beams are extended to asymmetrical open and wedged beams in isocentric treatment conditions. All required dosimetric parameters (normalized head scatter factors, phantom scatter correction factors, wedge factors, off-axis ratios, quality index, and depth dose parameters) are determined as a function of beam axis position in order to study their off-axis dependence. Measurements are performed for 6 MV and 18 MV photon beams provided by two different dual-energy linear accelerators, a GE Saturne 42 and a Varian 2100 CD linac.  相似文献   

2.
A coherent system for the use of scatter correction factors, determined at 10 cm depth, is described for dose calculations on the central axis of arbitrarily shaped photon beams. The system is suitable for application in both the fixed source-surface distance (SSD) and in the isocentric treatment set-up. This is in contrast to some other proposals where only one of these approaches forms the basis of the calculation system or where distinct quantities and data sets are needed. In order to derive the relations in the formalism, we introduced a separation of the phenomena related to the energy fluence in air and to the phantom scatter contribution to the dose. Both are used relative to quantities defined for the reference irradiation set-up. It is shown that dose calculations can be performed with only one set of basic beam data, obtained at a reference depth of 10 cm. These data consist for each photon beam quality of measured collimator and phantom scatter correction factors, in combination with a set of (percentage/relative) depth-dose or tissue-phantom ratio values measured along the central axis of the beam. Problems related to measurements performed at the depth of maximum absorbed dose, due to the electron contamination of the beam, are avoided in this way. Collimator scatter correction factors are obtained by using a mini-phantom, while phantom scatter correction factors are derived from measurements in a full scatter phantom in combination with the results of the mini-phantom measurements. For practical reasons the fixed SSD system was chosen to determine the data. Then, dose calculations in a fixed SSD treatment set-up itself are straightforward. Application in the isocentric treatment set-up needs simple conversion steps, while the inverse approach, from isocentric to fixed SSD, is described as well. Differences between the two approaches are discussed and the equations for the conversions are given.  相似文献   

3.
Thomsen MS  Ulsø N 《Medical physics》2002,29(10):2427-2432
The properties of a new cement based material for production of compensators are presented. Broad beam attenuation of 4-20 MV x rays by slabs of the material have been measured at various field sizes and depths in a large water phantom. For comparison the attenuation of aluminum was determined at some of the photon energies and it was found that the attenuation properties of the cement based material are very close to those of aluminum. At 6 and 18 MV, a comparison of different phantoms for attenuation measurements was carried out. For this investigation the ionization chamber was placed in a 50x50x50 cm3 water phantom, a 20x20x20 cm3 water equivalent plastic phantom, and a cylindrical mini-phantom. Agreement was obtained between the measurements in the large water phantom and in the water equivalent plastic phantom. The measurements carried out with the mini-phantom in a 6 MV x-ray beam gave a higher transmission versus absorber thickness than the transmission found with the water phantom resulting in a lower value of the effective attenuation coefficient. At 18 MV x rays the difference between the measurements in the water phantom and in the mini-phantom was less. This shows that a water equivalent plastic phantom with an area comparable with the largest field size applied can be used for measurements of effective attenuation coefficients, whereas a mini-phantom cannot be used directly, especially at low photon energies.  相似文献   

4.
A Monte Carlo study on internal wedges using BEAM   总被引:1,自引:0,他引:1  
  相似文献   

5.
A hybrid phantom-embedded extrapolation chamber (PEEC) made of Solid Water and bone-equivalent material was used for determining absorbed dose in a bone-equivalent phantom irradiated with clinical radiation beams (cobalt-60 gamma rays; 6 and 18 MV x rays; and 9 and 15 MeV electrons). The dose was determined with the Spencer-Attix cavity theory, using ionization gradient measurements and an indirect determination of the chamber air-mass through measurements of chamber capacitance. The collected charge was corrected for ionic recombination and diffusion in the chamber air volume following the standard two-voltage technique. Due to the hybrid chamber design, correction factors accounting for scatter deficit and electrode composition were determined and applied in the dose equation to obtain absorbed dose in bone for the equivalent homogeneous bone phantom. Correction factors for graphite electrodes were calculated with Monte Carlo techniques and the calculated results were verified through relative air cavity dose measurements for three different polarizing electrode materials: graphite, steel, and brass in conjunction with a graphite collecting electrode. Scatter deficit, due mainly to loss of lateral scatter in the hybrid chamber, reduces the dose to the air cavity in the hybrid PEEC in comparison with full bone PEEC by 0.7% to approximately 2% depending on beam quality and energy. In megavoltage photon and electron beams, graphite electrodes do not affect the dose measurement in the Solid Water PEEC but decrease the cavity dose by up to 5% in the bone-equivalent PEEC even for very thin graphite electrodes (<0.0025 cm). In conjunction with appropriate correction factors determined with Monte Carlo techniques, the uncalibrated hybrid PEEC can be used for measuring absorbed dose in bone material to within 2% for high-energy photon and electron beams.  相似文献   

6.
目的:介绍医用加速器常规光子射线的机器数据测量方法及剂量计算模型中基本参数的计算过程。以百分深度剂量与散射因子为基础数据,根据原散射线模型通过测量数据推导出原射线组织最大剂量比、散射最大剂量比、原射线在水中线性衰减系数、能量注量等,为进一步还原射野在水模体中的剂量分布提供方法与理论。方法:用Blue Phantom三维水箱在医科达Synergy加速器上测量6MV光子线的百分深度剂量、离轴比剂量、总散射因子、准直器散射因子,先从测量的百分深度剂量曲线中按照原散射模型剥离出原射线百分深度剂量,然后在Matlab软件中拟合处理测量的散射因子数据,外推出零野的模体散射因子,从而按照给定公式计算出组织最大剂量比、散射最大剂量比。按照离轴比剂量,利用平方反比规律推出最大开野在模体表面的能量注量。结果:计算出准直器散射因子、总散射因子的拟合公式,外推零野模体散射因子(s。)、根据原射线的百分深度剂量曲线计算出原射线在水中线性衰减系数,组织最大剂量比(TMR)、散射最大剂量比(SMR)、以及射野能量注量分布(Fluence Matrix)。结论:这些基本参数是剂量计算建模的关键,也是进一步研究各种剂量计算模型的基础。  相似文献   

7.
The International Atomic Energy Agency (IAEA TRS-398) and the American Association of Physicists in Medicine (AAPM TG-51) have published new protocols for the calibration of radiotherapy beams. These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standards laboratory's reference quality beam. This paper compares the recommendations of the two protocols in two ways: (i) by analysing in detail the differences in the basic data included in the two protocols for photon and electron beam dosimetry and (ii) by performing measurements in clinical photon and electron beams and determining the absorbed dose to water following the recommendations of the two protocols. Measurements were made with two Farmer-type ionization chambers and three plane-parallel ionization chamber types in 6, 18 and 25 MV photon beams and 6, 8, 10, 12, 15 and 18 MeV electron beams. The Farmer-type chambers used were NE 2571 and PTW 30001, and the plane-parallel chambers were a Scanditronix-Wellh?fer NACP and Roos, and a PTW Markus chamber. For photon beams, the measured ratios TG-51/TRS-398 of absorbed dose to water Dw ranged between 0.997 and 1.001, with a mean value of 0.999. The ratios for the beam quality correction factors kQ were found to agree to within about +/-0.2% despite significant differences in the method of beam quality specification for photon beams and in the basic data entering into kQ. For electron beams, dose measurements were made using direct N(D,w) calibrations of cylindrical and plane-parallel chambers in a 60Co gamma-ray beam, as well as cross-calibrations of plane-parallel chambers in a high-energy electron beam. For the direct N(D,w) calibrations the ratios TG-51/TRS-398 of absorbed dose to water Dw were found to lie between 0.994 and 1.018 depending upon the chamber and electron beam energy used, with mean values of 0.996, 1.006, and 1.017, respectively, for the cylindrical, well-guarded and not well-guarded plane-parallel chambers. The Dw ratios measured for the cross-calibration procedures varied between 0.993 and 0.997. The largest discrepancies for electron beams between the two protocols arise from the use of different data for the perturbation correction factors p(wall) and p(dis) of cylindrical and plane-parallel chambers, all in 60Co. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and the quantities in the two protocols.  相似文献   

8.
Two methods are compared for calculating the field-size dependence of the phantom scatter component of dose for x-ray beams. One model sums three Gaussian distributions; the other model is a two-parameter function. With a measurement of the beam quality as input to determine parameters, both models accurately reproduce the relative phantom scatter. However, there are important differences between the models. For all beam energies, the two-parameter model characterizes the absolute phantom scatter as a function of depth and field size, while, also for all beam energies, the six-parameter Gaussian model characterizes the relative phantom scatter at a single depth of 10 cm. For small field sizes, the phantom scatter calculated from the two-parameter model agrees with Monte Carlo calculations better than the Gaussian model. In the Gaussian model, the parameters can be obtained for beam energies between 60Co and 25 MV by linear interpolation based on the measured beam quality. In the two-parameter model, and for energies above 4 MV, the parameters can be obtained using linear functions of the dose-weighted average linear attenuation coefficient, which is related to beam quality.  相似文献   

9.
Pre-existing methods for photon beam spectral reconstruction are briefly reviewed. An alternative reconstruction method by scatter analysis for linear accelerators is introduced. The method consists in irradiating a small plastic phantom at standard 100 cm SSD and inferring primary beam energy spectral information based on the measurement with a standard Farmer chamber of scatter around the phantom at several specific scatter angles: a scatter curve is measured which is indicative of the primary spectrum at hand. A Monte Carlo code is used to simulate the scatter measurement set-up and predict the relative magnitude of scatter measurements for mono-energetic primary beams. Based on mono-energetic primary scatter data, measured scatter curves are analysed and the spectrum unfolded as the sum of mono-energetic individual energy bins using the Schiff bremsstrahlung model. The method is applied to an Elekta/SL18 6 MV photon beam. The reconstructed spectrum matches the Monte Carlo calculated spectrum for the same beam within 6.2% (average error when spectra are compared bin by bin). Depth dose values calculated for the reconstructed spectrum agree with physically measured depth dose data to within 1%. Scatter analysis is preliminarily shown to have potential as a practical spectral reconstruction method requiring few measurements under standard 100 cm SSD and feasible in any radiotherapy department using a phantom and a Farmer chamber.  相似文献   

10.
S Kim  C Liu  C Chen  J R Palta 《Medical physics》1999,26(6):949-955
A simple algorithm was developed for calculation of the in-air output at various source-to-detector distances (SDDs) on the central axis for wedged fields. In the algorithm we dealt independently with two effective sources, one for head scatter and the other for wedge scatter. Varian 2100C with 18 and 8 MV photon beams was used to examine this algorithm. The effective source position for head scatter for wedged fields was assumed to be the same as that for open fields, and the effective source position for wedge scatter was assumed to be a certain distance upstream from the physical location of the wedge. The shift of the effective source for wedge scatter, w, was found to be independent of field size. Moreover, we observed no systematic dependency of w on wedge angle or beam energy. One value, w = 5.5 cm, provided less than 1% difference in in-air outputs through the whole experimental range, i.e., 6 x 6 to 20 x 20 cm2 field size (15 x 20 cm2 for 60 degrees wedge), 15 degrees-60 degrees wedge angle, 80-130 cm SDD, and both 18 and 8 MV photon beams. This algorithm can handle the case in which use of a tertiary collimator with an external wedge makes the field size for the determination of wedge scatter different from that for head scatter. In this case, without the two-effective-source method, the maximum of 4.7% and 2.6% difference can be given by the inverse square method and one-effective-source method in a 45 degrees wedged field with 18 MV. Differences can be larger for thicker wedges. Enhanced dynamic wedge (EDW) fields were also examined. It was found that no second effective source is required for EDW fields.  相似文献   

11.
An empirical model of the factors that determine the central axis dose at 10 cm depth in water for 4 MV, 6 MV and 18 MV photon beams is presented. Backscattering from the variable collimators into the dose monitoring ionization chamber can cause a variation of -0.5% to +1.8% in the dose per monitor unit in accelerators with an electron facility. Forward emission towards the isocentre from the beam flattening filter and upper collimators is more dependent on the position of the upper variable collimator blades than the lower blades, so that they are not interchangeable in determining output factors, which can differ by up to 2%. The model includes the product of the monitor backscatter factor, normalized phantom scatter factor, normalized head scatter factor and inverse square law, corrected for the displacement of the virtual x-ray focus from the target. It can predict the dose to -/+0.83% for 4 MV, -/+0.80% for 6 MV photons and -/+0.82% for 18 MV photons. The normalized head scatter factor is a second-order polynomial of the modified equivalent square collimator, whose coefficients do not vary significantly with x-ray energy. The model was tested by comparison with independent measurements of output factor and generally agreed to around 1%.  相似文献   

12.
Ding GX 《Medical physics》2004,31(9):2527-2533
Our purpose in this study was to investigate whether the Monte Carlo simulation can accurately predict output factors in air. Secondary goals were to study the head scatter components and investigate the collimator exchange effect. The Monte Carlo code, BEAMnrc, was used in the study. Photon beams of 6 and 18 MV were from a Varian Clinac 2100EX accelerator and the measurements were performed using an ionization chamber in a mini-phantom. The Monte Carlo calculated in air output factors was within 1% of measured values. The simulation provided information of the origin and the magnitude of the collimator exchange effect. It was shown that the collimator backscatter to the beam monitor chamber played a significant role in the beam output factors. However the magnitude of the scattered dose contributions from the collimator at the isocenter is negligible. The maximum scattered dose contribution from the collimators was about 0.15% and 0.4% of the total dose at the isocenter for a 6 and 18 MV beam, respectively. The scattered dose contributions from the flattening filter at the isocenter were about 0.9-3% and 0.2-6% of the total dose for field sizes of 4x4 cm2-40x40 cm2 for the 6 and 18 MV beam, respectively. The study suggests that measurements of head scatter factors be done at large depth well beyond the depth of electron contamination. The insight information may have some implications for developing generalized empirical models to calculate the head scatter.  相似文献   

13.
The National Physical Laboratory (NPL) provides a high-energy photon calibration service using 4-19 MV x-rays and 60Co gamma-radiation for secondary standard dosemeters in terms of absorbed dose to water. The primary standard used for this service is a graphite calorimeter and so absorbed dose calibrations must be converted from graphite to water. The conversion factors currently in use were determined prior to the launch of this service in 1988. Since then, it has been found that the differences in inherent filtration between the NPL LINAC and typical clinical machines are large enough to affect absorbed dose calibrations and, since 1992, calibrations have been performed in heavily filtered qualities. The conversion factors for heavily filtered qualities were determined by interpolation and extrapolation of lightly filtered results as a function of tissue phantom ratio 20,10 (TPR20,10). This paper aims to evaluate these factors for all mega-voltage photon energies provided by the NPL LINAC for both lightly and heavily filtered qualities and for 60Co y-radiation in two ways. The first method involves the use of the photon fluence-scaling theorem. This states that if two blocks of different material are irradiated by the same photon beam, and if all dimensions are scaled in the inverse ratio of the electron densities of the two media, then, assuming that all photon interactions occur by Compton scatter the photon attenuation and scatter factors at corresponding scaled points of measurement in the phantom will be identical. The second method involves making in-phantom measurements of chamber response at a constant target-chamber distance. Monte Carlo techniques are then used to determine the corresponding dose to the medium in order to determine the chamber calibration factor directly. Values of the ratio of absorbed dose calibration factors in water and in graphite determined in these two ways agree with each other to within 0.2% (1sigma uncertainty). The best fit to both sets of results agrees with values determined in previous work to within 0.3% (1sigma uncertainty). It is found that the conversion factor is not sensitive to beam filtration.  相似文献   

14.
Palm A  Mattsson O 《Medical physics》2002,29(12):2756-2762
The implementation of protocols based on absorbed dose to water standards requires beam quality conversion factors, k(Q). Calculated values of k(Q) are available for ionization chambers used for reference dosimetry. Ideally, k(Q) should be experimentally determined at the same beam qualities as that of the user. In this work we measure k(Q) factors in clinical photon beams and compare them with calculated and measured values. Beam quality conversion factors are determined for clinical photon beams of nominal energies 4 MV, 6 MV, 15 MV, and 25 MV, for commonly used cylindrical ionization chambers. Twelve chambers of eight different types are used. For three of them, no experimental data have previously been available. The experimental procedure is based on measurements with ionization chambers and Fricke dosimetry in the reference beam (60Co gamma radiation) and in clinical linear accelerator beams. The k(Q) values determined in this work generally agree within 0.5% with previously reported experimental values both when %dd(10)x and TPR2010 are used for beam quality specification. The agreement with calculated data is generally within 0.5%, except for the 15 MV beam. For this beam the measured values are usually between 0.5% and 1% lower than the data taken from the TG-51 protocol or the TRS-398 code of practice. For three NE2571 chambers and three NE2581 chambers, the maximum observed deviation of individual k(Q) values is 0.2% and 0.4%, respectively.  相似文献   

15.
Basic dosimetric properties of 6 MV and 18 MV photon beams from a Varian Clinac 21EX accelerator operating without the flattening filter have been measured. These include dose rate data, depth dose dependencies and lateral profiles in a water phantom, total scatter factors and transmission factors of a multileaf collimator. The data are reviewed and compared with measurements for the flattened beams. The unflattened beams have the following: a higher dose rate by factors of 2.3 (6 MV) and 5.5 (18 MV) on the central axis; lower out-of-field dose due to reduced head scatter and softer spectra; less variation of the total scatter factor with field size; and less variation of the shape of lateral dose profiles with depth. The findings suggest that with a flattening filter free accelerator better radiation treatments can be developed, with shorter delivery times and lower doses to normal tissues and organs.  相似文献   

16.
This study investigates the feasibility of using Monte Carlo methods to assist the commissioning of photon beam output factors from a medical accelerator. The Monte Carlo code, BEAMnrc, was used to model 6 MV and 18 MV photon beams from a Varian linear accelerator. When excellent agreements were obtained between the Monte Carlo simulated and measured dose distributions in a water phantom, the entire geometry including the accelerator head and the water phantom was simulated to calculate the relative output factors. Simulated output factors were compared with measured data, which consist of a typical commission dataset for the output factors. The measurements were done using an ionization chamber in a water phantom at a depth of 10 cm with a source-detector distance of 100 cm. Square fields and rectangular fields with widths and lengths ranging from 4 cm to 40 cm were studied. The result shows a very good agreement (< 1.5%) between the Monte Carlo calculated and the measured relative output factors for a typical commissioning dataset. The Monte Carlo calculated backscatter factors to the beam monitor chamber agree well with measured data in the literature. Monte Carlo simulations have also been shown to be able to accurately predict the collimator exchange effect and its component for rectangular fields. The information obtained is also useful to develop an algorithm for accurate beam modelling. This investigation indicates that Monte Carlo methods can be used to assist commissioning of output factors for photon beams.  相似文献   

17.
For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace the focal and extra-focal sources with a single phase-space plane scored just above the highest adjustable collimator in a EGS/BEAM simulation of the linac. The phase-space plane is then used as photon source in a stochastic convolution/superposition dose engine. A photon sampled from the uncollimated phase-space plane is first propagated through an arbitrary collimator arrangement and then interacted in the simulation phantom. Energy deposition kernel rays are then randomly issued from the interaction points and dose is deposited along these rays. The electrons in the phase-space file are used to account for electron contamination. 6 MV and 18 MV photon beams from an Elekta SL linac are used as representative examples. Except for small corrections for monitor backscatter and collimator forward scatter for large field sizes (<0.5% with <20 x 20 cm2 field size), we found that the use of a single phase-space photon source provides accurate and self-consistent results for both relative and absolute dose calculations.  相似文献   

18.
In clinical photon beams, the dose outside the geometrical field limits is produced by photons originating from (i) head leakage, (ii) scattering at the beam collimators and the flattening filter (head scatter) and (iii) scattering from the directly irradiated region of the patient or phantom (internal scatter). While the first two components can be modified, e.g. by reinforcement of shielding components or by re-modeling the filter system, internal scatter remains an unavoidable contributor to the peripheral dose. Its relative magnitude compared to the other components, its numerical variation with beam energy, field size and off-axis distance as well as its spectral distribution are evaluated in this study. We applied a detailed Monte Carlo (MC) model of our 6/15 MV Siemens Primus linear accelerator beam head, provided with ideal head leakage shielding conditions (multi-leaf collimator without gaps) to assess the head scatter contribution. Experimental values obtained under real shielding conditions were used to evaluate the head leakage contribution. It was found that the MC-computed internal scatter doses agree with the results of our previous measurements, that internal scatter is the major contributor to the peripheral dose in the near periphery while head leakage prevails in the far periphery, and that the lateral decline of the internal scatter dose can be represented by the sum of two exponentials, with an asymptotic tenth value of 18 to 19 cm. Internal scatter peripheral doses from various elementary beams are additive, so that their sum increases approximately in proportion with field size. The ratio between normalized internal scatter doses at 6 and 15 MV is approximately 2:1. The energy fluence spectra of the internal scatter component at all points of interest outside the field have peaks near 500 keV. The fact that the energy-shifted internal scatter constitutes the major contributor to the dose in the near periphery has a general bearing for dosimetry, i.e. for energy-dependent detector responses and dose conversion factors, for the relative biological effectiveness and for second primary malignancy risk estimates in the peripheral region.  相似文献   

19.
We have benchmarked photon beam simulations with the EGS4 user code BEAM [Rogers et al., Med. Phys. 22, 503-524 (1995)] by comparing calculated and measured relative ionization distributions in water from the 10 and 20 MV photon beams of the NRC linac. Unlike previous calculations, the incident electron energy is known independently to 1%, the entire extra-focal radiation is simulated, and electron contamination is accounted for. The full Monte Carlo simulation of the linac includes the electron exit window, target, flattening filter, monitor chambers, collimators, as well as the PMMA walls of the water phantom. Dose distributions are calculated using a modified version of the EGS4 user code DOSXYZ which additionally allows scoring of average energy and energy fluence in the phantom. Dose is converted to ionization by accounting for the (L/rho)water(air) variation in the phantom, calculated in an identical geometry for the realistic beams using a new EGS4 user code, SPRXYZ. The variation of (L/rho)water(air) with depth is a 1.25% correction at 10 MV and a 2% correction at 20 MV. At both energies, the calculated and the measured values of ionization on the central axis in the buildup region agree within 1% of maximum ionization relative to the ionization at 10 cm depth. The agreement is well within statistics elsewhere. The electron contamination contributes 0.35(+/- 0.02) to 1.37(+/- 0.03)% of the maximum dose in the buildup region at 10 MV and 0.26(+/- 0.03) to 3.14(+/- 0.07)% of the maximum dose at 20 MV. The penumbrae at 3 depths in each beam (in g/cm2), 1.99 (dmax, 10 MV only), 3.29 (dmax, 20 MV only), 9.79 and 19.79, agree with ionization chamber measurements to better than 1 mm. Possible causes for the discrepancy between calculations and measurements are analyzed and discussed in detail.  相似文献   

20.
The BaFBrI:Eu2+ storage phosphor plate (SPP) is a reusable radiation image detector, widely used in diagnostic computed radiography, x-ray crystallography and radioactive tracer studies. When exposed to ionizing radiation, the SPP stores a latent image until it is scanned with a red reading laser which causes blue photostimulated luminescent (PSL) photons to be emitted. The mechanism of formation of the latent image is still poorly understood, especially for megavoltage photon beams. In order to gain insight into this mechanism and aid applications to high-energy beam dosimetry, the authors have directly determined the SPP generation efficiency, W, the energy required to produce one quantum of emitted PSL when it is irradiated by 60Co and 6 MV photon beams. This was done in four steps: 1. The SPP, in a water-equivalent plastic (WEP) phantom, was exposed to a 60Co or 6 MV beam, which had been calibrated to give a known absorbed dose to water in a water phantom at the position of the sensitive layer of the SPP. 2. Monte Carlo simulations were used to calculate the ratio of the dose to the sensitive layer in the WEP phantom to the dose to water at the same position in a water phantom. 3. A bleaching experiment was used to determine the number of photons emitted by a plate given a known dose. 4. The generation efficiency was calculated from the number of photons and the dose. This method is much more direct than previous calculations for kilovoltage x-ray beams based on quantum noise analysis. W was found, within experimental uncertainty, to be 190 eV for 60Co and 160 eV for 6 MV, independent of dose. The values for kilovoltage x-ray beams determined previously agree, within their large uncertainty, with these values for megavoltage beams.  相似文献   