首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
MRCP诊断术后胆管结石:2D、3D FASE序列对照   总被引:5,自引:0,他引:5  
目的评价磁共振胰胆管成像(MRCP)二维高级快速自旋回波(2D FASE)序列和三维高级快速自旋回波(3D FASE)序列对胆道术后残余对胆道术后病变的诊断价值.方法对72例胆道术后出现不明原因发热、黄疸、肝功能异常、右上腹痛等症状患者同时进行MRCP 2种序列检查,结果分别与手术、直接胆道造影对照.结果MRCP 2D FASE序列、3D FASE序列诊断肝内胆管结石的敏感度、特异度、阳性预测值、阴性预测值、准确率分别为43.5%、100%、100%、79%、81.9%以及69.6%、95.9%、88.9%、87%、87.5%.2种序列诊断有显著性差异(P<0.05).MRCP 2D FASE序列和3D FASE序列诊断胆总管及吻合口结石的敏感度、特异度、阳性预测值、阴性预测值、准确率分别为77.8%、96.3%、87.5%、92.9%、91.7%以及83.3%、98.1%、93.8%、94.6%、94.4%.2种序列相比无显著性差异(P>0.05).结论MRCP 2种序列对胆系结石均有很高的检出率.3D FASE序列较2DFASE序列能检出更细小的结石.  相似文献   

2.
Yuri Sankaw  曹毅媛 《放射学实践》2006,21(11):1098-1098
自90年代磁共振胰胆管成像(MRCP)开始应用以来,随着快速自旋回波序列的发展,技术和图像的质量都有着不断改善。现回顾性评估三维快速恢复自旋回波序列(3D FRFSE)与二维单次激发快速自旋回波序列(2D SSFSE)对胆道的重现及图像质量的优劣(Radiology,2006,238:549-559)。如今对于S  相似文献   

3.
目的 探讨对比分析三维屏气梯度-自旋回波(3D BH-GRASE序列)与三维呼吸触发快速自旋回波(3D RTTSE)序列进行磁共振胰胆管成像(MRCP)的应用价值。方法 选取在我院因怀疑胰胆管病变而行腹部MRI检查的患者,均接受3D RT-TSE序列与3D BH-GRASE序列MRCP扫描。比较两种序列扫描时间、图像质量评分及显示病变情况。结果 3D BH-GRASE序列的扫描时间为(16.4±1.7)s明显短于3D RT-TSE序列的(258.6±31.2)s,差异有统计学意义(P<0.05);3D BH-GRASE序列扫描图像胆囊、肝内胆管、胆囊管、胰管、胆总管等主要分支评分均明显高于3D RTTSE序列,差异有统计学意义(P<0.05);两种扫描序列方法对各区域病变检出率差异无统计学意义(P>0.05)。结论MRCP检查应用3D BH-GRASE序列扫描能够保证图像质量及显示病变,同时缩短扫描时间。  相似文献   

4.
目的 探讨单次屏气采集的快速三维梯度自旋回波(3D-GRASE)序列与二维快速自旋回波(2D-FSE)序列在磁共振胰胆管造影(MRCP)中的图像差异。方法 搜集2021年3月至2021年7月在本院行MRCP检查的患者77例,同时扫描2D-MRCP序列和快速3D-MRCP序列,分别计算图像的信噪比(SNR)和对比噪声比(CNR),同时对图像质量进行主观评价。结果 2D-MRCP序列图像的SNR 22.60±18.23,3D-MRCP序列的SNR 24.02±16.73,差异无统计学意义。2D-MRCP序列的CNR 76.46±48.78,低于3D-MRCP序列的胆总管CNR 129.20±66.58,差异有统计学意义(P<0.01)。图像质量、伪影评分无统计学差异。各胰胆管分支的显示中,肝总管、胆总管、胰管的显示有统计学差异(P<0.001)。结论 3D-GRASE序列的图像质量与2D-FSE序列的图像无统计学差异,符合诊断要求,且3D-GRASE序列具有可全方位观察,减少肠道影响的优点。  相似文献   

5.
目的探讨面肌痉挛及三叉神经痛的神经与周围血管显示的最佳MR扫描序列。方法对40例面肌痉挛及三叉神经痛病人的脑池段面神经和二叉神经用三维时间飞跃-扰相梯度回波(3DTOF-SPGR)和三维快速高级自旋回波(3DFASE)2种扫描序列进行扫描,并对其与周围血管的关系显示进行分析。结果38例经手术证实,3DTOF-SPGR序列图像显示其中33例面神经和三叉神经单侧存在邻近血管压迫或接触,5例无接触,3DFASE序列图像显示其中26例面神经和三叉神经单侧存在邻近血管压迫或接触,12例无接触。统计学分析结果表明2种扫描序列显示面神经和三叉神经对邻近血管的压迫或接触差异有显著性意义(X^2=5.14,P:0.016)。结论就显示神经与邻近血管的关系而言,3DTOF-SPGR序列明显优于3DFASE序列,是临床上面肌痉挛和三义神经痛病人行MR检查首选的扫描序列。  相似文献   

6.
磁共振胰胆管成像对诊断胆胰系统疾病的临床应用价值   总被引:12,自引:4,他引:8  
目的评价磁共振胰胆管成像(MRCP)技术在胆胰系统疾病诊断中的应用价值.方法68例患者进行了MRCP检查,其中正常对照组11例,各种胰胆管病变组57例.扫描使用ELSCINTSGR2.0T超导磁共振成像仪,体线圈及呼吸门控触发技术.平扫采用自旋回波(SE)常规成像;MRCP采用快速自旋回波(FSE)重T2加权像进行薄层扫描.所得图像用最大强度投影法(MIP)进行三维(3D)重建.结果MRCP能清晰显示胰胆管的解剖结构,对胆道梗阻程度和梗阻部位判断的确诊率达100%,梗阻原因的确诊率达91.2%.结论MRCP检查的成功率高,胰胆管解剖结构显示清晰,适应于各种胰胆管疾病的诊断,可作为该系统疾病诊断的首选方法  相似文献   

7.
口服钆喷替酸葡甲胺溶液行MR胰胆管成像的初步临床应用   总被引:21,自引:1,他引:21  
目的 应用口服钆喷替酸葡甲胺 (Gd DTPTA)溶液作为胃肠道阴性对比剂 ,以降低胃肠道背景高信号 ,提高磁共振胰胆管成像 (MRCP)的图像质量。方法 用 5 0ml药瓶将Gd DTPA溶液稀释成不同浓度 (分别稀释为 5倍、10倍、15倍、2 0倍 ) ,并设空白对照组 ,行常规及MRCP扫描 ,以选择最佳的对比剂浓度。对 15例疑有胰胆管系统疾病的病人行口服对比剂前后MRCP检查 ,对比剂为稀释 5倍的Gd DTPA溶液 ( 1 488g/L) 2 5 0ml,磁场强度为 1 5T。MRCP成像方法有二维单层快速自旋回波 (FSE)序列及半傅立叶单次激发快速自旋回波 (HASTE)序列。结果 实验部分结果表明稀释 5倍的Gd DTPA溶液T2 WI信号降低最明显 ,达 5 9 3 % ,HASTE序列信号强度降低 82 45 % ,单层MRCP时所有稀释倍数液体信号强度均下降达 90 %以上。所有病例口服对比剂后MRCP扫描胃及十二指肠内液体高信号均较前有明显下降 ,图像质量明显提高 ,以单层MRCP序列胃肠道液体高信号抑制最明显。口服Gd DTPA溶液前后 ,胆总管、胰管及胆囊结构的显示程度等级评分差异有显著性意义 (P <0 0 5 )。结论 稀释 5倍的口服Gd DTPA溶液是一种安全有效地降低胃肠道液体高信号强度、改善MRCP图像质量的胃肠道阴性对比剂  相似文献   

8.
磁共振胰胆管成像对恶性胆道梗阻的诊断价值   总被引:7,自引:2,他引:5  
目的:评价磁共振胰胆管成像(MRCP)对恶性胆道梗阻性疾病的临床诊断价值,探讨肝外恶性胆道梗阻的MRCP、MRI诊断及鉴别诊断。方法:回顾性分析69例恶性胆道梗阻患者的MRI及MRCP表现,并与CT、US、直接胆道造影和手术病理结果对照。MRCP采用二维(2D)和/或三维(3D)屏气半傅立叶转换快速自旋回波(FASE)序列T2加权成像技术。结果:69例MRCP检查均一次成功,全部病例胰胆管显示满意,与直接胆道造影对照,二者所获图像极其相似。MRCP对恶性胆道梗阻定位诊断准确率为98.5%定性诊断准确率为95.6%。结论:MRCP对恶性胆道梗阻定位及定性诊断优于CT和US,是诊断恶性胆道梗阻的一种有效的非侵袭性的检查方法。  相似文献   

9.
目的评价采用枸橼酸铁铵作为胃肠道口服阴性对比剂对提高梗阻性黄疸患者磁共振胰胆管成像(MRCP)检查质量的作用。方法对50例临床怀疑梗阻性黄疸的患者行MRCP检查,将患者随机分为2组:试验组25例患者,在检查前30min时口服枸橼酸铁铵冲剂;对照组25例患者,不服用任何对比剂。观察患者对口服对比剂的耐受性;对所有患者进行冠状位厚层的半傅立叶单次激励快速自旋回波序列(HASTE)和呼吸触发的3D快速自旋回波序列(RT-3D-TSE)扫描。由2位放射科医师单盲阅片,对2组患者MRCP图像的对比效果和图像质量作评估和分级。结果所有患者对枸橼酸铁铵溶液都有很好的耐受性。口服枸橼酸铁铵溶液后所有试验组MRCP图像上的胃肠道高信号都有很大程度的抑制,对比效果和图像质量有明显改善,胆道解剖结构显示的清晰性明显提高。结论口服枸橼酸铁铵溶液作为安全的胃肠道阴性对比剂在梗阻性黄疸患者的MRCP检查中可以有效降低胃肠道高信号所造成的影响及假象,改善胆道系统的显示情况,便于诊断。  相似文献   

10.
目的 探讨磁共振2D和3D MRCP 2种成像技术对胆道系统疾病的诊断效能.方法 回顾性分析102例均行3.0T 2D和3D MRCP成像的胆管疾病的病例,其中结石37例,肿瘤30例,炎症12例,胆肠吻合术后复查病例23例.依据图像评价标准对102例2D和3D MRCP图像质量进行评价,比较2种成像方法对胆管结石和肿瘤性病变诊断效能.结果 102例中,2D MRCP图像优、良、差的病例数分别为67例、30例和5例;3D MRCP图像优、良、差的病例数分别为54例、40例和8例,经统计学处理2D和3D MRCP图像优良率之间没有显著性差异.37例胆管系统结石的病例中,2D MRCP诊断结石符合率为91%,3D MRCP诊断结石符合率为78%;30例各种肿瘤中,2D MRCP诊断肿瘤符合率为70%,3D MRCP诊断肿瘤符合率为87%.在P=0.05的显著性水平上,2D和3D MRCP在诊断结石和肿瘤效能上没有显著差异.结论 3.0T MRCP 2D和3D 2种成像技术图像质量和对结石和肿瘤的显示上并不存在很大的差异性.  相似文献   

11.
MRCP 2D FASE序列对胆道术后病变的诊断价值   总被引:9,自引:1,他引:9  
目的 评价磁共振胆胰管成像(MRCP)二维快速自旋回波序列(2D FASE)对胆道术后并发症的诊断价值。资料与方法 对72例胆道术后(胆囊切除术48例,胆总管探查术8例,肝管空肠吻合术16例)出现不明原因发热、黄疸、右上腹痛等症状患者进行MRCP检查,由2位放射科医生阅片,着重观察是否存在残余胆囊、胆管狭窄、胆道结石、吻合口狭窄等术后并发症,并与直接胆管造影、手术和病理结果对照分析。结果 MRCP 2D FASE对残余胆囊的敏感性、特异性、阳性预测值、阴性预测值、准确率分别为92.3%、91.7%、92.3%、97.1%、95.8%;对胆管狭窄分别为90.9%、97.8%、90.9%、97.8%、96.4%;对胆道结石分别为79.2%、100%、100%、90.6%、93.1%;对胆管扩张均为100%;对胆肠吻合口定位准确率为100%;对吻合口狭窄诊断的准确率为87.5%。结论 MRCP 2D FASE序列是诊断胆道术后病变的一种准确、非侵入性的检查方法。  相似文献   

12.
PURPOSE: To compare 2D single-shot Fast Spin-Echo (FSE) and two 3D FSE MR cholangiopancreatography (MRCP) sequences with different slice thickness in the evaluation of normal and abnormal biliary and pancreatic duct systems. MATERIALS AND METHODS: Thirty-two consecutive patients, both with normal biliary and pancreatic ducts (n=14) and with different biliary and/or pancreatic duct disease (n=18) underwent MRCP with a 1.5 T superconductive magnet. One 2D single-shot FSE and two 3D FSE MRCP sequences with different slice thickness (1.6 mm and 3 mm) were performed in each patient. Images were analysed with regards to: artefacts (0=none, 1=minimal, 2=present but not affecting the diagnostic evaluation, 3=present and affecting the diagnostic evaluation), image quality (0=non-diagnostic, 1=poor, 2=fair, 3=good, 4=excellent), duct conspicuity (0=not-visible, 1=poor, 2=good, 3=excellent), diagnostic confidence (possible presence of dilatations, stones and stenoses). RESULTS: Artefacts were rarely present, without significant differences among the three sequences. The 2D single-shot FSE sequence provided a significantly better image quality and significantly better conspicuity of the intrahepatic and pancreatic ducts in comparison to both the 1.6-mm and 3-mm thickness 3D FSE sequences. The three sequences yielded identical results in the detection of 17 cases of dilatation and 10 cases of stenosis as well as in the evaluation of their degree. Stones in the biliary tree were detected in 6 cases with the 2D single-shot FSE sequence, in 5 cases in the MIP images of the 3D FSE sequence with slice thickness of 1.6 mm and in 4 cases in the MIP images of the 3D FSE sequence with slice thickness of 3 mm. The diagnostic confidence did not show statistically significant differences among the three sequences. CONCLUSIONS: The 2D single-shot FSE sequence proved to be superior to the 3D FSE sequences in the evaluation of normal and abnormal biliary and pancreatic duct systems.  相似文献   

13.
单次激发磁共振胰胆管造影的临床应用   总被引:6,自引:0,他引:6  
目的:探讨单次激发快速自旋回波(SSFSE)序列磁共振胰胆管造影的临床应用价值。方法:采用屏气、重T2 加权、单次激发快速自旋回波(SSFSE)序列、二维多平面成像技术做MR胰胆管造影80 例,其中30 例为正常者,50例疑为胰胆系疾病的病人。结果:30例正常者的胰胆管和胆囊的显示率为100% 。50例疑为胰胆系疾病的病人,MRCP良好显示胰胆系病变部位及扩张的胰胆管,结合腹部常规MR,获得理想的综合影像诊断。结论:SSFSE序列MRCP是一种安全简便、无创伤性的胰胆管影像学检查新技术,快速成像,图像清晰,具有重要的临床应用价值。  相似文献   

14.
低场强磁共振胰胆管成像技术的临床应用   总被引:5,自引:0,他引:5  
目的:探讨低场强MR胰胆管成像技术及临床应用价值。材料与方法:以0.3低场强MR、重T2WI MR水成像技术做胰胆管造影40例。采用快速自旋回波(FSE)非屏气扫描技术,加大TR/TE技术参数。图像经计算机叠加重建处理。结果:40全名有11例胰胆管正常;29例患有胰胆疾患,其中14例经手术病理证实。阳性患者均能显示各类疾病的异常改变,阴性者能展示胆总管、胆囊、肝总管、左右肝管的形态。结论:低场强M  相似文献   

15.
OBJECTIVE: To compare axial and coronal fast Spin-Echo fat-suppressed T2-weighted sequences with three-dimensional (3D) maximum intensity projection (MIP) images in patients with suspected pancreaticobiliary obstruction. MATERIAL AND METHODS: MR cholangiopancreatography (MRCP) was performed in 108 consecutive patients with a non-breath-hold, fat-suppressed, 2D, heavily T2-weighted fast spin-echo sequence in coronal plane. Axial T1- and T2-weighted images were previously obtained. In addition, 3D reconstructions of the coronal images were analysed separately by using a MIP algorithm. Both two-dimensional (2D) (axial and coronal) and 3D MIP images were separately evaluated by two readers in conference and their results were compared with that of endoscopic retrograde cholangiopancreatography, percutaneous trans-hepatic cholangiography, surgery and/or imaging follow-up. Statistical analysis of 2D and 3D MRCP images in diagnosing the level and probable cause of pancreaticobiliary obstruction were separately calculated. RESULTS: 106/108 of MRCP examinations were judged diagnostic by the two reviewers for adequacy of visualisation of the biliary and pancreatic ducts. Sensitivity, specificity, positive predictive value, negative predictive value and global diagnostic accuracy of 2D (axial and coronal) and 3D MRCP images in diagnosing the pancreaticobiliary obstruction were 94 and 57%,, 95 and 93%, 97 and 92%, 91 and 60%, 94 and 72% respectively. CONCLUSION: Our results do indicate a higher global accuracy for axial and coronal fast Spin-Echo fat-suppressed T2-weighted sequences versus 3D MIP images in diagnosis of the level and probable cause of pancreaticobiliary obstruction and stress the limitations of 3D images in depiction of small intraductal pathology such as calculi and biliary neoplastic.  相似文献   

16.
高场强磁共振胰胆管成像的临床应用   总被引:4,自引:0,他引:4  
目的:评价高场强MR胰胆管成像的临床应用价值。方法:回顾分析用高场强磁共振水成像技术行胰胆管成像的病人2252例。采用快速自旋回波(FSE)技术,图像经三维(3D)最大信号强度投影(MIP)后处理。并将所有结果为阳性的病例与手术或FIE或ERCP的结果相对照。结果:在2252例病人中阴性564例,阳性1688例。此技术可从不同角度清楚描述胰胆管的形态,展示各种疾病的异常影像改变,其敏感性为91%-100%,阳性预测值达85%-100%,准确性为94%-99%。结论:高场强MR胰胆管成像具有较高的准确性,能为胰胆管系统疾病的诊断和术后评价提供可靠的依据。  相似文献   

17.
比较单次激发磁共振胰胆管成像(SSMRCP)和常规磁共振胰胆管造影(CMRCP),评价SSMRCP的临床应用 价值。材料与方法81例梗阻性黄疸、1例胆管-空肠吻合术后及61例无黄疸患者行OMRC、SSMRC单层及多层扫描, 比较两种技术诊断的准确性。结果三个序列均能显示胆管病变部位、疾病特征、近侧扩张胆管以及远侧正常胰胆管;显 示扩张胆管直径三个序列间没有显著性差异;SSMRCP多层显示胆管病变细节较好,而SSMRCP单层显示胰管则明显优 于另两种方法。结论SSSMRCP可代替OMRCP,准确地、更快速地诊断胆管系统疾病,并能更好地显示正常胰管。  相似文献   

18.
磁共振胰胆管造影的临床应用   总被引:79,自引:3,他引:79  
卢延  洪闻 《中华放射学杂志》1997,31(10):663-667
目的:评价MR胰胆管造影的临床应用价值。材料与方法:用重T2MR水成像技术做MR胰胆管造影163例。采用快速自旋回波(FSE)和脂肪抑制技术,图像经三维(3D)最大信号强度投影(MIP)后处理。结果:临床检查163例中,61例为胰胆正常者;102例疑为胰胆疾患者,其中96例阳性,6例阴性。此技术可清楚描画胰胆管的形态,展示各种疾病的异常改变,诊断正确性高。结论:MR胰胆管造影是安全、可靠的非侵袭性的检查方法,不用造影剂,能较好地评价胰胆系统的解剖和病理变化,提高诊断能力。  相似文献   

19.
单次屏气超快速MRI在胆系梗阻性疾患诊断中的应用   总被引:42,自引:4,他引:38  
目的 ⑴评估单次屏气半傅立叶采集单次激发快速自旋回波磁共振胆胰管造影(HASTE-MRCP)对于胆系梗阻性疾患胆胰管的显示情况及对疾病诊断的准确性。⑵评估单次屏气HASTE-MRCP与真稳态进动快速成像(True FISP)T2*W1相结合在胆系梗阻性疾患诊断中的应用价值。方法 132例胆系梗阻患者术前行MR检查(Siemens1.5T Magnetojm Vision)。所有扫描序列均采用单次屏气快速扫描并配以体部相控  相似文献   

20.
 目的:评估磁共振胰胆管造影成像的技术和应用价值.方法:用重T<,2>加权快速自旋回波(TSE)序列和脂肪抑制技术作MR胰胆管造影成像45例.所有图像均作最大信号强度投影(MIP)后处理.结果:45例患者中,胆系疾患28例,胆系外疾患17例.此技术可清楚描画胆管及各种疾病的异常改变,对正常胰管及其分支的显示不佳.结论:MR胰胆管造影不用造影剂,是安全、可靠、非损伤性的检查方法,在胰胆管疾病诊断方面具有很大潜力.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏