1.
Responsive contrast agents (RCAs) composed of lanthanide(III) ion (Ln3R) complexes with a variety of1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (DOTA4S) derivatives have shown great potential as molecular imaging agents for MR. A variety of LnDOTA–tetraamide complexes have been demonstrated as RCAs for molecular imaging using chemical exchange saturation transfer (CEST). The CEST method detects proton exchange between bulk water and any exchangeable sites on the ligand itself or an inner sphere of bound water that is shifted by a paramagnetic Ln3R ion bound in the core of the macrocycle. It has also been shown that molecular imaging is possible when the RCA itself is observed (i.e. not its effect on bulk water) using a method called biosensor imaging of redundant deviation in shifts (BIRDS). The BIRDS method utilizes redundant information stored in the nonexchangeable proton resonances emanating from the paramagnetic RCA for ambient factors such as temperature and/or pH.Thus, CEST and BIRDS rely on exchangeable and nonexchangeable protons, respectively, for biosensing. We posited that it would be feasible to combine these two biosensing features into the same RCA (i.e. dual CEST and BIRDS properties). A complex between europium(III) ion (Eu3R) and DOTA–tetraglycinate [DOTA–(gly)S4] was used to demonstrate that its CEST characteristics are preserved, while its BIRDS properties are also detectable. The in vitro temperature sensitivity of EuDOTA–(gly)S4 was used to show that qualitative MR contrast with CEST can be calibrated using quantitative MR mapping with BIRDS, thereby enabling quantitative molecular imaging at high spatial resolution.  相似文献   

2.
The praseodymium complex of 10-(2-methoxyethyl)-1,4,7,10-tetraaza-cyclododecane-1,4,7-tr iacetate) was evaluated as a temperature-sensitive contrast agent using the temperature dependence (approximately 0.12 ppm degrees C(-1)) of the chemical shift of its methoxy side group signal. Pr[MOE-DO3A] was employed in combination with spectroscopic imaging (SI) methods for the determination of spatially resolved 2D and 3D temperature distributions in phantoms. Conventional SI and fast echo planar SI sequences (EPSI) were implemented on a 4.7 T MR imaging system fulfilling the demands for non-invasive thermometry (NIT) with respect to thermal and temporal resolution, being <1 degree C and <20 s total measuring time, respectively. The sequences are based on a fast spin echo SI method taking into account the very short relaxation times of the Pr complex methoxy group (T1 = 28 ms, T2 = 13 ms) and its chemical shift difference (-24 ppm) from water. Calibration curves were measured in a uniformly heated water phantom and 2D SI methods were applied to dynamic heating experiments. The average differences between the temperatures measured via fibreoptic thermometer and those derived from the spectroscopic methods were < or =0.2 degrees C. Furthermore, 3D EPSI experiments with a 16 x 16 x 16 matrix size yielded temperature measurements within 17 s from voxels of size 3 x 3 x 3 mm3.  相似文献   

3.
Spectroscopic signals which emanate from complexes between paramagnetic lanthanide (III) ions (e.g. Tm3+) and macrocyclic chelates (e.g. 1,4,7,10‐tetramethyl‐1,4,7,10‐tetraazacyclododecane‐1,4,7,10‐tetraacetate, or DOTMA4–) are sensitive to physiology (e.g. temperature). Because nonexchanging protons from these lanthanide‐based macrocyclic agents have relaxation times on the order of a few milliseconds, rapid data acquisition is possible with chemical shift imaging (CSI). Thus, Biosensor Imaging of Redundant Deviation in Shifts (BIRDS) which originate from nonexchanging protons of these paramagnetic agents, but exclude water proton detection, can allow molecular imaging. Previous two‐dimensional CSI experiments with such lanthanide‐based macrocyclics allowed acquisition from ~12‐μL voxels in rat brain within 5 min using rectangular encoding of k space. Because cubical encoding of k space in three dimensions for whole‐brain coverage increases the CSI acquisition time to several tens of minutes or more, a faster CSI technique is required for BIRDS to be of practical use. Here, we demonstrate a CSI acquisition method to improve three‐dimensional molecular imaging capabilities with lanthanide‐based macrocyclics. Using TmDOTMA, we show datasets from a 20 × 20 × 20‐mm3 field of view with voxels of ~1 μL effective volume acquired within 5 min (at 11.7 T) for temperature mapping. By employing reduced spherical encoding with Gaussian weighting (RESEGAW) instead of cubical encoding of k space, a significant increase in CSI signal is obtained. In vitro and in vivo three‐dimensional CSI data with TmDOTMA, and presumably similar lanthanide‐based macrocyclics, suggest that acquisition using RESEGAW can be used for high spatiotemporal resolution molecular mapping with BIRDS. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
This work was undertaken to investigate the feasibility of using a cylindrical phased array for transoesophaeal thermal ablation under magnetic resonance (MR) imaging guidance. Sixty-four transducers (0.45 mm wide by 15 mm tall), operating at 4.6 MHz, were spread around the periphery of a 10.6-mm-diam cylinder. The head of the applicator was covered with a 65-microm thick latex balloon attached using watertight seals. This envelope was inflated with degassed water to provide acoustic coupling between the transducer and the tissues. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. Ex vivo experiments conducted on 47 samples of pig liver under MR temperature monitoring demonstrated the ability of this applicator to generate cylindrical or sector-based coagulation necroses at depths up to 19 mm with excellent angular precision by applying 20 W/cm2. MR thermometry was performed in "real-time" with segmented echo-planar imaging gradient echo sequences. The temporal resolution was approximately 3 s/ image. The average value for the temperature baseline in liver tissue close to the applicator was 0.3 degrees C (+/- 0.6 degrees C). The thermal dose delivered in tissues was computed on-line during temperature imaging. Excellent MR compatibility was demonstrated, all MR acquisitions were performed without susceptibility artifacts or radio-frequency interferences with the ultrasound device. Thermal lesions identified on post-treatment follow up showed good correlation with online MR thermometry data. The individual differences between measurements performed visually and using MRI thermal dose maps were about 11% of volume. This study demonstrated the feasibility of thermal ablation using a phased array intraluminal ultrasound applicator and on-line MR monitoring.  相似文献   

5.
Chemical shifts of complexes between paramagnetic lanthanide ions and macrocyclic chelates are sensitive to physiological variations (of temperature and/or pH). Here we demonstrate utility of a complex between thulium ion (Tm3+) and the macrocyclic chelate 1,4,7,10‐tetramethyl 1,4,7,10‐tetraazacyclododecane‐1,4,7,10‐tetraacetate (or DOTMA4?) for absolute temperature mapping in rat brain. The feasibility of TmDOTMA? is compared with that of another Tm3+‐containing biosensor which is based on the macrocyclic chelate 1,4,7,10‐tetraazacyclododecane‐ 1,4,7,10‐tetrakis(methylene phosphonate) (or DOTP8?). In general, the in vitro and in vivo results suggest that Biosensor Imaging of Redundant Deviation in Shifts (BIRDS) which originate from these agents (but exclude water) can provide temperature maps with good accuracy. While TmDOTP5? emanates three major distinct proton resonances which are differentially sensitive to temperature and pH, TmDOTMA? has a dominant pH‐insensitive proton resonance from a ? CH3 group to allow higher signal‐to‐noise ratio (SNR) temperature assessment. Temperature (and pH) sensitivities of these resonances are practically identical at low (4.0T) and high (11.7T) magnetic fields and at nominal repetition times only marginal SNR loss is expected at the lower field. Since these resonances have extremely short relaxation times, high‐speed chemical shift imaging (CSI) is needed to detect them. Repeated in vivo CSI scans with BIRDS demonstrate excellent measurement stability. Overall, results with TmDOTP5? and TmDOTMA? suggest that BIRDS can be reliably applied, either at low or high magnetic fields, for functional studies in rodents. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
In magnetic resonance (MR) imaging, the most widely used and accurate method for measuring temperature is based on the shift in proton resonance frequency (PRF). However, inter-scan motion and bulk magnetic field shifts can lead to inaccurate temperature measurements in the PRF-shift MR thermometry method. The self-reference PRF-shift MR thermometry method was introduced to overcome such problems by deriving a reference image from the heated or treated image, and approximates the reference phase map with low-order polynomial functions. In this note, a new approach is presented to calculate the baseline phase map in self-reference PRF-shift MR thermometry. The proposed method utilizes the phase gradient to remove the phase unwrapping step inherent to other self-reference PRF-shift MR thermometry methods. The performance of the proposed method was evaluated using numerical simulations with temperature distributions following a two-dimensional Gaussian function as well as phantom and in vivo experimental data sets. The results from both the numerical simulations and experimental data show that the proposed method is a promising technique for measuring temperature.  相似文献   

7.
Clinical application of high-temperature thermal therapy as a treatment for solid tumours requires an accurate and close to real-time method for assessing tissue damage. Imaging methods that detect structural changes during heating may underestimate the extent of thermal damage. This is due to the occurrence of delayed damage manifested at tissue locations exposed to temperatures lower than those required to cause immediate structural changes. An alternative approach is to measure temperature and then calculate the expected damage based on the temperature history at each tissue location. Magnetic resonance (MR) imaging methods now allow temperature maps of the target and surrounding tissues to be generated in almost real-time. The aim of this work was to evaluate whether thermal damage zones calculated on the basis of MR thermometry maps measured during heating correspond to actual tissue damage as measured after treatment by histological methods and MR imaging. Four male rabbits were treated with high-temperature thermal therapy delivered in the brain by a single microwave antenna operating at 915 MHz. MR scanning was performed before, during and after treatment in a 1.5 T whole-body scanner. Temperature maps were produced using the proton resonance frequency (PRF) shift method of MR thermometry. In addition, conventional T1-weighted and T2-weighted spin-echo images were acquired after treatment. Thermal damage zones corresponding to cell death, microvascular blood flow stasis and protein coagulation were calculated using an Arrhenius analysis of the MR temperature/time course data. The calculated zones were compared with the lesions seen on histopathological examination of the brains which were removed within 6-8 h of treatment. The results showed that calculated damage zones based on MR thermometry agreed well with areas of damage as assessed using histology after heating was completed. The data suggest that real-time calculations of final expected thermal damage based on an Arrhenius analysis of MR temperature data may provide a useful method of real-time monitoring of thermal therapy when combined with conventional T2-weighted images taken after treatment.  相似文献   

8.
Li X  Qian Y  Liu T  Hu X  Zhang G  You Y  Liu S 《Biomaterials》2011,32(27):6595-6605
We report on the fabrication of multifunctional polymeric unimolecular micelles as an integrated platform for cancer targeted drug delivery and magnetic resonance imaging (MRI) contrast enhancement under in vitro and in vivo conditions. Starting from a fractionated fourth-generation hyperbranched polyester (Boltorn H40), the ring-opening polymerization of ?-caprolactone (CL) from the periphery of H40 and subsequent terminal group esterification with 2-bromoisobutyryl bromide afforded star copolymer-based atom transfer radical polymerization (ATRP) macroinitiator, H40-PCL-Br. Well-defined multiarm star block copolymers, H40-PCL-b-P(OEGMA-co-AzPMA), were then synthesized by the ATRP of oligo(ethylene glycol) monomethyl ether methacrylate (OEGMA) and 3-azidopropyl methacrylate (AzPMA). This was followed by the click reaction of H40-PCL-b-P(OEGMA-co-AzPMA) with alkynyl-functionalized cancer cell-targeting moieties, alkynyl-folate, and T(1)-type MRI contrast agents, alkynyl-DOTA-Gd (DOTA is 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetrakisacetic acid), affording H40-PCL-b-P(OEGMA-Gd-FA). In aqueous solution, the amphiphilic multiarm star block copolymer exists as structurally stable unimolecular micelles possessing a hyperbranched polyester core, a hydrophobic PCL inner layer, and a hydrophilic P(OEGMA-Gd-FA) outer corona. H40-PCL-b-P(OEGMA-Gd-FA) unimolecular micelles are capable of encapsulating paclitaxel, a well-known hydrophobic anticancer drug, with a loading content of 6.67 w/w% and exhibiting controlled release of up to 80% loaded drug over a time period of ~120 h. In vitro MRI experiments demonstrated considerably enhanced T(1) relaxivity (18.14 s(-1) mM(-1)) for unimolecular micelles compared to 3.12 s(-1) mM(-1) for that of the small molecule counterpart, alkynyl-DOTA-Gd. Further experiments of in vivo MR imaging in rats revealed good accumulation of unimolecular micelles within rat liver and kidney, prominent positive contrast enhancement, and relatively long duration of blood circulation. The reported unimolecular micelles-based structurally stable nanocarriers synergistically integrated with cancer targeted drug delivery and controlled release and MR imaging functions augur well for their potential applications as theranostic systems.  相似文献   

9.
Catheter ablation using radio frequency (RF) has been used increasingly for the treatment of cardiac arrhythmias and may be combined with proton resonance frequency shift (PRFS) ?based MR thermometry to determine the therapy endpoint. We evaluated the suitability of two different MR thermometry sequences (TFE and TFE‐EPI) and three blood suppression techniques. Experiments were performed without heating, using an optimized imaging protocol including navigator respiratory compensation, cardiac triggering, and image processing for the compensation of motion and susceptibility artefacts. Blood suppression performance and its effect on temperature stability were evaluated in the ventricular septum of eight healthy volunteers using multislice double inversion recovery (MDIR), motion sensitized driven equilibrium (MSDE), and inflow saturation by saturation slabs (IS). It was shown that blood suppression during MR thermometry improves the contrast‐to‐noise ratio (CNR), the robustness of the applied motion correction algorithm as well as the temperature stability. A gradient echo sequence accelerated by an EPI readout and parallel imaging (SENSE) and using inflow saturation blood suppression was shown to achieve the best results. Temperature stabilities of 2 °C or better in the ventricular septum with a spatial resolution of 3.5 × 3.5 × 8mm3 and a temporal resolution corresponding to the heart rate of the volunteer, were observed. Our results indicate that blood suppression improves the temperature stability when performing cardiac MR thermometry. The proposed MR thermometry protocol, which optimizes temperature stability in the ventricular septum, represents a step towards PRFS‐based MR thermometry of the heart at 3 T. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
Magnetic resonance imaging (MRI) thermometry has been utilized for in vivo evaluation of thermal exposure induced by a focused ultrasound beam. A simulation study of the focused ultrasound beam was conducted to select imaging parameters for reducing the error due to the spatial and temporal averaging of MRI. Temperature imaging based on the proton resonance frequency shift was utilized to obtain the temperature distribution during sonication in the skeletal muscle of eight rabbits. MRI-derived temperature information was then used to calculate the thermal dose distribution induced by the sonication and to estimate the coagulated tissue volume. The tissue changes were also evaluated directly by taking the T2-weighted and the contrast agent enhanced T1-weighted MR images. Errors in the temperature and thermal dose measurements were found to be minimal using the following parameters: slice thickness = 3 mm, voxel dimension = 0.6 mm, and scan time per image = 3.4 s. The estimated dimensions of the coagulated tissue volume were in good agreement with the tissue damages seen on the contrast agent enhanced T1-weighted images. The tissue damage seen on the histology was closely matched to the ones seen on the T2-weighted images. This study showed that MRI thermometry has significant potential for both monitoring the thermal exposure and evaluating the tissue damage. This would allow real-time control of the sonication parameters to optimize clinical treatments.  相似文献   

11.
Blood temperature is a key determinant of tissue temperature and can be altered under normal physiological states, such as exercise, in diseases such as stroke or iatrogenically in therapies which modulate tissue temperature, such as therapeutic hypothermia. Currently available methods for the measurement of arterial and venous temperatures are invasive and, for small animal models, are impractical. Here, we present a methodology for the measurement of intravascular and tissue temperature by magnetic resonance imaging (MRI) using the lanthanide agent TmDOTMA? (DOTMA, tetramethyl‐1,4,7,10‐tetraazacyclododecane‐1,4,7,10‐tetraacetic acid; Tm, thulium). The approach makes use of phase‐sensitive imaging measurements, combined with spectrally selective excitation, to monitor the temperature‐dependent shift in the resonance of proton nuclei associated with water and with methyl groups of TmDOTMA?. Measurements were first made in a flow phantom modelling diastolic blood flow in the mouse aorta or inferior vena cava (IVC) and imaged using 7‐T preclinical MRI with a custom‐built surface coil. Flowing and static fluid temperatures agreed to within 0.12°C for these experiments. Proof‐of‐concept experiments were also performed on three healthy adult mice, demonstrating temperature measurements in the aorta, IVC and kidney following a bolus injection of contrast agent. A small (0.7–1°C), but statistically significant, higher kidney temperature compared with the aorta (p  = 0.002–0.007) and IVC (p  = 0.003–0.03) was shown in all animals. These findings demonstrate the feasibility of the technique for in vivo applications and illustrate how the technique could be used to explore the relationship between blood and tissue temperature for a wide range of applications.  相似文献   

12.
The purpose of this work was to validate in phantom studies and demonstrate the clinical feasibility of MR proton resonance frequency thermometry at 1.5 T with segmented gradient-echo echo planar imaging (GRE-EPI) sequences during liver tumour radiofrequency (RF) ablation. Classical GRE acquisitions and segmented GRE-EPI acquisitions were performed at 1.5 T during simultaneous RF heating with an MR-compatible RF electrode placed in an agar gel phantom. Temperature increments were calculated and compared with four optical temperature probe measurements using Bland- Altman analysis. In a preliminary clinical feasibility study, the rapid GRE-EPI sequence (echo train length = 13) was used for MR temperature monitoring of RF ablation of liver tumours in three patient procedures. For phantom experiments, the Bland-Altman mean of differences between MR and optical probe temperature measurements was <0.4 degrees C, and the 95% limits of agreement value was <1.4 degrees C. For the in vivo studies, respiratory-triggered GRE-EPI acquisitions yielded a temperature accuracy of 1.3 +/- 0.4 degrees C (acquisition time = 0.6 s/image, spatial coverage of three slices/respiratory cycle). MR proton resonance frequency thermometry at 1.5 T yields precise and accurate measurements of temperature increment with both classical GRE and rapid GRE-EPI sequences. Rapid GRE-EPI sequences minimize intra-scan motion effects and can be used for MR thermometry during RF ablation in moving organs. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

13.
Quantitative characterization of the intracellular water (1)H MR signal from cultured cells will provide critical biophysical insight into the MR signal from tissues in vivo. Microbeads provide a robust immobilization substrate for the many mammalian cell lines that adhere to surfaces and also provide sufficient cell density for observation of the intracellular water MR signal. However, selective observation of the intracellular water MR signal from perfused, microbead-adherent mammalian cells requires highly effective suppression of the extracellular water MR signal. We describe how high-velocity perfusion of microbead-adherent cells results in short apparent (1)H MR longitudinal and transverse relaxation times for the extracellular water in a thin slice selected orthogonal to the direction of flow. When combined with a spin-echo pulse sequence, this phenomenon provides highly effective suppression of the extracellular water MR signal. This new method is exploited here to quantify the kinetics of water exchange from the intracellular to extracellular spaces of HeLa cells. The time constant describing water exchange from intracellular to extracellular spaces, also known as the exchange lifetime for intracellular water, is 119 +/- 14 ms.  相似文献   

14.
In order to investigate simultaneous MR temperature imaging and direct validation of tissue damage during thermal therapy, temperature‐dependent signal changes in proton resonance frequency (PRF) shifts, R2* values, and T1‐weighted amplitudes are measured from one technique in ex vivo tissue. Using a multigradient echo acquisition and the Stieglitz‐McBride algorithm, the temperature sensitivity coefficients of these parameters are measured in each tissue at high spatiotemporal resolutions (1.6x1.6x4mm3, ≤ 5sec) at the range of 25‐61 °C. Non‐linear changes in MR parameters are examined and correlated with an Arrhenius rate dose model of thermal damage. Using logistic regression, the probability of changes in these parameters is calculated as a function of thermal dose to determine if changes correspond to thermal damage. Temperature sensitivity of R2* and, in some cases, T1‐weighted amplitudes are statistically different before and after thermal damage occurred. Significant changes in the slopes of R2* as a function of temperature are observed. Logistic regression analysis shows that these changes could be accurately predicted using the Arrhenius rate dose model (Ω = 1.01 ± 0.03), thereby showing that the changes in R2* could be direct markers of protein denaturation. Overall, by using a chemical shift imaging technique with simultaneous temperature estimation, R2* mapping and T1‐W imaging, it is shown that changes in the sensitivity of R2* and, to a lesser degree, T1‐W amplitudes are measured in ex vivo tissue when thermal damage is expected to occur. These changes could possibly be used for direct validation of thermal damage in contrast to model‐based predictions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
The success of hyperthermia treatments is dependent on thermal dose distribution. However, the three-dimensional temperature distribution remains largely unknown. Without this knowledge, the relationship between thermal dose and outcome is noisy, and therapy cannot be optimized. Accurate computations of thermal distribution can contribute to an optimized therapy. The hyperthermia modeling group in the Department of Radiotherapy, University Medical Center Utrecht devised a Discrete Vasculature [Kotte et al., Phys. Med. Biol. 41, 865-884 (1996)] model that accounts for the presence of vessel trees in the computational domain. The vessel tree geometry is tracked using magnetic resonance (MR) angiograms to a minimum diameter between 0.6 and 1 mm. However, smaller vessels (0.2-0.6 mm) are known to account for significant heat transfer. The hyperthermia group at Duke University Medical Center has proposed using perfusion maps derived from dynamic-enhanced magnetic resonance imaging to account for the tissue perfusion heterogeneity [Craciunescu et al., Int. J. Hyperthermia 17, 221-239 (2001)]. In addition, techniques for noninvasive temperature measurements have been devised to measure temperatures in vivo [Samulski et al., Int. J. Hypertherminal, 819-829 (1992)]. In this work, a patient with high-grade sarcoma has been retrospectively modeled to determine the temperature distribution achieved during a hyperthermia treatment. Available for this model were MR depicted geometry, angiograms, perfusion maps, as necessary for accurate thermal modeling, as well as MR thermometry data for validation purposes. The vasculature assembly through modifiable potential program [Van Leeuwen et al., IEEE Trans. Biomed. Eng. 45, 596-604 (1998)] was used in order to incorporate the traceable large vessels. Temperature simulations were made using different approaches to describe perfusion. The simulated cases were the bioheat equation with constant perfusion rates per tissue type, perfusion maps alone, tracked vessel tree and perfusion maps, and generated vessel tree. The results were compared with MR thermometry data for a single patient data set, concluding that a combination between large traceable vessels and perfusion map yields the best results for this particular patient. The technique has to be repeated on several patients, first with the same type of malignancy, and after that, on patients having malignancies at other different sites.  相似文献   

16.
MR thermometry offers the possibility to precisely guide high-intensity focused ultrasound (HIFU) for the noninvasive treatment of kidney and liver tumours. The objectives of this study were to demonstrate therapy guidance by motion-compensated, rapid and volumetric MR temperature monitoring and to evaluate the feasibility of MR-guided HIFU ablation in these organs. Fourteen HIFU sonications were performed in the kidney and liver of five pigs under general anaesthesia using an MR-compatible Philips HIFU platform prototype. HIFU sonication power and duration were varied. Volumetric MR thermometry was performed continuously at 1.5 T using the proton resonance frequency shift method employing a multi-slice, single-shot, echo-planar imaging sequence with an update frequency of 2.5 Hz. Motion-related suceptibility artefacts were compensated for using multi-baseline reference images acquired prior to sonication. At the end of the experiment, the animals were sacrificed for macroscopic and microscopic examinations of the kidney, liver and skin. The standard deviation of the temperature measured prior to heating in the sonicated area was approximately 1 °C in kidney and liver, and 2.5 °C near the skin. The maximum temperature rise was 30 °C for a sonication of 1.2 MHz in the liver over 15 s at 300 W. The thermal dose reached the lethal threshold (240 CEM(43) ) in two of six cases in the kidney and four of eight cases in the liver, but remained below this value in skin regions in the beam path. These findings were in agreement with histological analysis. Volumetric thermometry allows real-time monitoring of the temperature at the target location in liver and kidney, as well as in surrounding tissues. Thermal ablation was more difficult to achieve in renal than in hepatic tissue even using higher acoustic energy, probably because of a more efficient heat evacuation in the kidney by perfusion.  相似文献   

17.
Proton spectroscopy has been evaluated as a method for quantifying radiation induced changes in polyacrylamide gel dosimeters. A calibration was first performed using BANG-type gel samples receiving uniform doses of 6 MV photons from 0 to 9 Gy in 1 Gy intervals. The peak integral of the acrylic protons belonging to acrylamide and methylenebisacrylamide normalized to the water signal was plotted against absorbed dose. Response was approximately linear within the range 0-7 Gy. A large gel phantom irradiated with three, coplanar 3 x 3 cm square fields to 5.74 Gy at isocentre was then imaged with an echo filter technique to map the distribution of monomers directly. The image, normalized to the water signal, was converted into an absolute dose map. At the isocentre the measured dose was 5.69 Gy (SD = 0.09) which was in good agreement with the planned dose. The measured dose distribution elsewhere in the sample shows greater errors. A T2 derived dose map demonstrated a better relative distribution but gave an overestimate of the dose at isocentre of 18%. The data indicate that MR measurements of monomer concentration can complement T2-based measurements and can be used to verify absolute dose. Compared with the more usual T2 measurements for assessing gel polymerization, monomer concentration analysis is less sensitive to parameters such as gel pH and temperature, which can cause ambiguous relaxation time measurements and erroneous absolute dose calculations.  相似文献   

18.
The feasibility of using MR thermometry for temperature feedback to control a transurethral ultrasound heating applicator with planar transducers was investigated. The sensitivity of a temperature-based feedback algorithm to spatial (control point area, slice thickness, angular alignment) and non-spatial (imaging time, temperature uncertainty) parameters was evaluated through numerical simulations. The angular alignment of the control point with the ultrasound beam was an important parameter affecting the average spatial error in heat delivery. The other spatial parameters were less influential, thus providing an opportunity to reduce spatial resolution for increased SNR in the MR imaging. The update time was the most important non-spatial parameter determining the performance of the control algorithm. Combined non-spatial and spatial parameters achieved acceptable performance with a voxel size of 3 mm x 3 mm, a 10 mm slice thickness and a 5 s update time. Temperature uncertainty of up to 2 degrees C had little effect on the performance of the control algorithm but did reduce the average error slightly due to a systematic, noise-induced overestimation of the boundary temperature. These simulations imply that MR thermometry performed on clinical 1.5 T imaging systems is of sufficient quality for use as thermal feedback for conformal prostate thermal therapy with transurethral ultrasound heating applicators incorporating planar transducers.  相似文献   

19.
Over 20 000 MR systems are currently installed worldwide and, although the majority operate at magnetic fields of 1.5 T and below (i.e. about 70%), experience with 3‐T (in high‐field clinical diagnostic imaging and research) and 7‐T (research only) human MR scanners points to a future in functional and metabolic MR diagnostics. Complementary to previous studies, this review attempts to provide an overview of ultrahigh‐field MR research with special emphasis on emerging clinical applications at 7 T. We provide a short summary of the technical development and the current status of installed MR systems. The advantages and challenges of ultrahigh‐field MRI and MRS are discussed with special emphasis on radiofrequency inhomogeneity, relaxation times, signal‐to‐noise improvements, susceptibility effects, chemical shifts, specific absorption rate and other safety issues. In terms of applications, we focus on the topics most likely to gain significantly from 7‐T MR, i.e. brain imaging and spectroscopy and musculoskeletal imaging, but also body imaging, which is particularly challenging. Examples are given to demonstrate the advantages of susceptibility‐weighted imaging, time‐of‐flight MR angiography, high‐resolution functional MRI, 1H and 31P MRSI in the human brain, sodium and functional imaging of cartilage and the first results (and artefacts) using an eight‐channel body array, suggesting future areas of research that should be intensified in order to fully explore the potential of 7‐T MR systems for use in clinical diagnosis. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
Paramagnetic agents that utilize two mechanisms to provide physiological information by magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI) are described. MRI with chemical exchange saturation transfer (CEST) takes advantage of the agent's exchangeable protons (e.g., -OH or -NHx, where 2 ≥ x ≥ 1) to create pH contrast. The agent's incorporation of non-exchangeable protons (e.g., -CHy, where 3 ≥ y ≥ 1) makes it possible to map tissue temperature and/or pH using an MRSI method called biosensor imaging of redundant deviation in shifts (BIRDS). Hybrid probes based upon 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate chelate (DOTA4−) and its methylated analog (1,4,7,10-tetraazacyclododecane-α, α′, α″, α‴-tetramethyl-1,4,7,10-tetraacetate, DOTMA4−) were synthesized, and modified to create new tetra-amide chelates. Addition of several methyl groups per pendent arm of the symmetrical chelates, positioned proximally and distally to thulium ions (Tm3+), gave rise to favorable BIRDS properties (i.e., high signal-to-noise ratio (SNR) from non-exchangeable methyl proton peaks) and CEST responsiveness (i.e., from amide exchangeable protons). Structures of the Tm3+ probes elucidate the influence of methyl group placement on sensor performance. An eight-coordinate geometry with high symmetry was observed for the complexes: Tm-L1 was based on DOTA4−, whereas Tm-L2 and Tm-L3 were based on DOTMA4−, where the latter contained an additional carboxylate at the distal end of each arm. The distance of Tm3+ from terminal methyl carbons is a key determinant for sustaining BIRDS temperature sensitivity without compromising CEST pH contrast; however, water solubility was influenced by introduction of hydrophobic methyl groups and hydrophilic carboxylate. Combined BIRDS and CEST detection of Tm-L2 , which features two high-SNR methyl peaks and a strong amide CEST peak, should enable simultaneous temperature and pH measurements for high-resolution molecular imaging in vivo.  相似文献   