Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs).

Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies.

Results: Patients with surgery: 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery: In 4 out of 9 patients, no NPTs were identified at MDCT.

Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT.  相似文献   

2.
Purpose: To determine the effects of detector configuration, as well as vessel orientation, on the depiction accuracy of arterial stenosis using four-channel multidetector-row helical computed tomography (MDCT) angiography in vitro.

Material and Methods: Five acrylic vessel phantoms (3 mm in diameter with 25 or 50% stenosis, or 5 mm with 25, 50, or 75% stenosis) were scanned with a four-channel MDCT scanner at five vessel orientations (0, 30, 45, 60, and 90° to the z-axis) using 4×1.25, 2.5, 3.75, and 5.0-mm detector configurations at beam pitches of 0.75 and 1.5. The percentage of stenosis was calculated by the ratio of the full width at half maximum for stenotic and non-stenotic portions of the phantom, and compared to the actual known values.

Results: A detector configuration of 4×1.25 mm provided good reproducibility, as well as high accuracy for assessing vessel stenosis, while a 4×2.5-mm or wider detector configuration caused underestimations of stenosis. Although the phantoms perpendicular to the z-axis were underestimated, the errors were kept in clinically acceptable ranges using the 4×1.25-mm detector configuration.

Conclusion: Four-channel MDCT accurately discerns stenosis for vessel phantoms of 3 or 5 mm in diameter at any orientation when using a detector configuration of 4×1.25 mm.  相似文献   

3.
Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH).

Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized.

Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements.

Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733).

Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension.  相似文献   

4.
Purpose: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique.

Material and Methods: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software.

Results: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery.

Conclusion: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.  相似文献   

5.
Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established.

Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography.

Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n = 10).

Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader.

Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material.  相似文献   

6.
Background: Contrast-enhanced magnetic resonance angiography (CE-MRA) is less prone to flow-related signal intensity loss than three-dimensional time-of-flight (3D TOF) MRA and may therefore be more sensitive for detection of residual patency in platinum coil-treated intracranial aneurysms.

Purpose: To compare MRA and CE-MRA in the follow-up of intracranial aneurysms treated with platinum coils.

Material and Methods: CE-MRA and 3D TOF MRA (pre- and postcontrast injection) of the intracranial vasculature was performed at 1.5T in 38 patients (47 aneurysms) referred for DSA in the follow-up of coiled intracranial aneurysms.

Results: DSA showed aneurysm patency in 22/47 investigations. Patent aneurysm components were observed with CE-MRA in 18/22 cases, and with 3D TOF MRA in 21/22 cases. There was no significant difference in patent aneurysm component size between CE-MRA and 3D TOF MRA. In addition, CE-MRA showed six, 3D TOF MRA before contrast injection showed seven, and 3D TOF MRA after contrast injection showed eight cases with patent aneurysm components not observed on DSA.

Conclusion: 3D TOF MRA was highly sensitive for detection of patent aneurysm components, and at least as sensitive as CE-MRA. Residual aneurysm patency seems to be better visualized with MRA than with DSA in some cases.  相似文献   

7.
Purpose: To propose a technique for standardizing volume-rendering technique (VRT) protocols and to compare this with maximum intensity projection (MIP) in regard to image quality and diagnostic confidence in stenosis diagnosis with magnetic resonance angiography (MRA).

Material and Methods: Twenty patients were examined with MRA under suspicion of renal artery stenosis. Using the histogram function in the volume-rendering software, the 95th and 99th percentiles of the 3D data set were identified and used to define the VRT transfer function. Two radiologists assessed the stenosis pathology and image quality from rotational sequences of MIP and VRT images.

Results: Good overall agreement (mean κ = 0.72) was found between MIP and VRT diagnoses. The agreement between MIP and VRT was considerably better than that between observers (mean κ = 0.43). One of the observers judged VRT images as having higher image quality than MIP images.

Conclusion: Presenting renal MRA images with VRT gave results in good agreement with MIP. With VRT protocols defined from the histogram of the image, the lack of an absolute gray scale in MRI need not be a major problem.  相似文献   

8.
Background: The introduction of multidetector-row computed tomography (MDCT) has revolutionized the initial management of multiply injured patients. This technology has the potential to improve the imaging of traumatic vascular injuries.

Purpose: To evaluate the quality of multidetector-row computed tomography angiography (MDCTA) of the carotid arteries in the setting of a routine whole-body trauma scan.

Material and Methods: 87 trauma patients underwent a routine whole-body CT scan in a 16-detector-row scanner including an MDCTA with a reconstructed axial slice thickness of 3 mm. Images were reviewed by three experienced radiologists with emphasis on image quality. Contrast density, severity, and origin of artifacts and the occurrence of vessel lesions were assessed for different vessel segments.

Results: 3642 separate vessel segments were evaluated. Contrast density was rated good or sufficient for diagnosis in 99.8%. A total of 67.3% of vessel segments were free of artifacts, while 27.9% of vessel segments showed minor artifacts not impairing diagnostic evaluation. Clinically relevant artifacts obscuring a vessel segment occurred in 4.7% and were mostly caused by dental hardware. Four dissections of the internal carotid artery were diagnosed by all three radiologists.

Conclusion: As a rapid screening test for blunt carotid artery injury, integration of MDCTA in the routine imaging workup of trauma patients utilizing a whole-body CT trauma scan is possible and practicable. Image quality is mostly sufficient for diagnosis, but impaired in a few cases by artifacts deriving primarily from dental hardware.  相似文献   

9.
Purpose: To report a technique developed for visualizing cervical nerve roots and distal nerve fibers using diffusion-weighted magnetic resonance imaging employing parallel imaging.

Material and Methods: We performed maximum intensity projection for a stack of isotropic axial diffusion-weighted images obtained with parallel imaging applying a motion-probing gradient in six directions with a b-value of 500 s/mm2 in a preliminary series of 13 subjects.

Results: This method worked well for visualizing the spinal cord and most of the nerve roots, the dorsal root ganglia, and proximal peripheral nerves.

Conclusion: Although the technique remains limited in depicting the brachial plexus and distal nerves, the ability to visualize the proximal peripheral nervous system at the cervical level is promising.  相似文献   

10.
Purpose: To investigate the angulation, length, and structural variations of the styloid process (SP) by multidetector computed tomography (MDCT).

Material and Methods: MDCT scans were performed in 283 cases (127 M and 156 F, age range 18-77 years). The length of the SP and its angulation on the transverse and sagittal planes were measured. Structural variations of the SP were observed by means of three-dimensional (3D) and multiplanar reconstruction (MPR) images.

Results: The length of the bony SP on both sides varied from 0 to 62 mm (mean 26.8±10.0 mm). Angulation ranged between 55° and 90.5° (7 2.7±6.6) in the transversal plane and between 76° and 110° (93.5±6.9) in the sagittal plane. Morphologically, the SP showed a considerable amount of variation. A solitary SP was present in 168 individuals (59.4%). In 9 individuals (3.1%), the SP was duplicated (4 unilateral and 5 bilateral). Sixty-one persons (21.6%) showed an incomplete ossified SP (42 unilateral and 19 bilateral), whereas in 7 individuals (2.5%) a bony SP was absent entirely (7 unilateral). In 38 individuals (13.4%), the stylohyoid ligament was ossified (16 entirely, 22 partial). In all individuals, 3D and MPR images showed the SP in its entire length.

Conclusion: MDCT with 3D CT and MPR of SP may show further detailed information related to SP. Not only the length of the SP, but also its 3D orientation, should be in focus in anatomical and clinical studies.  相似文献   

11.
Purpose: To study the application of magnetic resonance elastography (MRE) in the human brain.

Material and Methods: An external force actuator was developed, which produced propagating shear waves in brain tissue. A modified phase-contrast gradient-echo sequence was developed. The propagating shear waves within the brain were directly imaged. The wave images were processed to obtain the elasticity image. Shear waves at 100 Hz, 150 Hz, and 200 Hz were applied.

Results: The propagating shear waves in the brain were visualized on wave images. The elasticity image revealed the difference in tissue elasticity between gray and white matter of the brain.

Conclusion: MRE could be an imaging technique for assessing the elasticity of brain tissue.  相似文献   

12.
Background: Portal vein embolization (PVE) is now widely accepted as a useful preoperative procedure in selected patients undergoing extended hepatectomy. However, the effect of PVE on the growth of liver tumors has not been fully elucidated.

Purpose: To retrospectively evaluate the effects of PVE on the growth of liver tumors in the embolized lobes.

Material and Methods: Eight patients with a primary liver tumor, six hepatocellular carcinomas (HCC) and two cholangiocellular carcinomas (CCC), were studied. The growth rates of the tumors in the embolized lobes and non-embolized liver parenchyma were calculated using the computed tomography (CT) volume values at the time of tumor identification, and before and after PVE.

Result: The median tumor growth rate was 0.59 cm3/day (range 0.22-6.01 cm3/day) before PVE and 2.37 cm3/day (range 0.29-13.97 cm3/day) after PVE (P = 0.018). The tumor growth acceleration ratios ranged from 1.50 to 7.46 (median 2.65) in the six HCCs, and were 1.00 and 1.32 in the two CCCs. There was no apparent correlation between the tumor growth rate after PVE and the growth rate of non-embolized liver parenchyma (median 6.00 cm3/day, range 1.24-11.0 cm3/day).

Conclusion: Liver tumor growth in an embolized lobe accelerates after PVE, in patients with HCC.  相似文献   

13.
Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series.

Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts.

Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels were analyzed in random order regarding visibility and motion artifacts.

Results: Visibility using MDCT step-and-shoot was significantly better than or equal to SSCT step-and-shoot for segmental bronchi and fissures, but not for subsegmental bronchi. For MDCT helical, visibility was equal to or better than SSCT step-and-shoot for segmental bronchi, but not for fissures and subsegmental bronchi. Concerning motion artifacts, MDCT step-and-shoot and MDCT helical were significantly better than or equal to SSCT step-and-shoot.

Conclusion: The image quality (accounting for motion artifacts and visibility) of SSCT step-and-shoot and MDCT step-and-shoot is comparable. The visibility of anatomic structures in images from MDCT helical is inferior to HRCT step-and-shoot.  相似文献   

14.
Purpose: To evaluate controversial results regarding the effect of the contrast medium (CM) iothalamate on renal medullary blood flow by applying two different methods simultaneously.

Material and Methods: The outer medullary blood flow (OMBF) response was estimated using laser-Doppler flowmetry and hydrogen gas wash-out (microelectrodes) simultaneously. Outer medullary oxygen tension (PO2) was measured using Clark type microelectrodes. Iothalamate was injected i.v. at 1600 mg I/kg body weight for 2 min.

Results: CM induced a transient 28% decrease in OMBF as measured with the laser Doppler. The hydrogen gas wash-out rate was reduced by 50%, indicating a reduced perfusion. CM induced a transient 60% reduction in PO2, while renal fluid and electrolyte excretion increased several fold.

Conclusion: The CM iothalamate reduces outer medullary perfusion as estimated by two different techniques applied simultaneously. The PO2 in the same region was also reduced. Previous controversies regarding the effect of iothalamate on OMBF can be explained by extreme dosage and injection rates greatly exceeding clinical relevance.  相似文献   

15.
Background: A longstanding hypothesis that correlates fluid dynamic forces and atherosclerotic disease has led to numerous analytical, numerical, and experimental studies over the years because it is very difficult to measure the hemodynamic variables of blood in vivo.

Purpose: To investigate the technique of visualization and quantitation of hemodynamic variables at carotid artery bifurcation in vivo by combining computational fluid dynamics (CFD) and vascular imaging.

Material and Methods: Twenty-six healthy volunteers underwent magnetic resonance (MR) angiography of the bilateral carotid artery by a 3.0T whole-body scanner. Hemodynamic variables at these carotid bifurcations were calculated and visualized by combining vascular imaging post-processing and CFD.

Results: The average velocity of the carotid bifurcation in the systolic phase and the diastolic phase was 0.46±0.24 m/s and 0.23±0.05 m/s, respectively. Eddy current and back flows were observed at bifurcation and the lateral part of the proximal internal carotid arteries (ICA) and external carotid arteries (ECA), and the shapes of them changed with phases of the cardiac cycle, which were significant at the middle of the systolic phase and faded out quickly downstream of the ICA and ECA. The average range of wall shear stress (WSS) at the bifurcation was 4.36±1.32 Pa, and the maximum WSS was 18.02±4.11 Pa. The WSS map revealed a large region of low WSS at the carotid bulb and extended to the outer wall in the proximal end of the ICA (the lowest value was below 0.5 Pa), and there was also a small region of low WSS at the outer wall in the proximal end of the ECA.

Conclusion: CFD combined with vascular imaging can calculate and visualize hemodynamic variables at carotid bifurcation in vivo individually.  相似文献   

16.
Background: A method to describe pelvic rotations between pairs of standard sequential pelvic anteroposterior radiographs based on a pelvic phantom is described in a former study.

Purpose: To expand this method into clinical use based on clinical data.

Material and Methods: Teardrop distances were measured on 262 pelvic radiographs from 46 patients in a clinical material using a computer program designed to perform measurements on digital radiographs. Anthropometric data recorded from 141 pelvises in an anatomical collection were employed in a computer program designed to simulate radiographs of virtual objects. Virtual rotations of the pelvises were carried out with 4653 virtual radiographs obtained. Virtual radiographic measures were analyzed.

Results: A statistically significant difference of 8 mm between mean teardrop distance in females (120 mm) and males (112 mm) was found in the clinical material. A set of formulas describing the relations between differences of two rotation ratios and pelvic rotations were derived. Four simple regression analyses were carried out with the use of virtual measures. Adjusted teardrop distances were implemented.

Conclusion: A clinical method to describe pelvic rotations using standard pelvic radiographs was developed.  相似文献   

17.
Background: Contrast-induced nephropathy (CIN) is a serious complication of the use of iodinated contrast media (CM), and is associated with increased morbidity and mortality.

Purpose: To investigate whether radiologists take sufficient measures to prevent CIN in computed tomography (CT).

Material and Methods: 2005 survey of 509 European radiologists who had ≥3 years' experience and performed ≥50 CT scans/week.

Results: The most common methods used to identify patients at risk of CIN were renal function measurements (64%), clinical judgment (55%), and patient questionnaires (31%); 9% made no routine attempt to identify at-risk patients. The most common preventive protocols used in at-risk patients included: intravenous (i.v.) saline volume repletion (59%) or oral hydration (52%) before/after CT; use of low-osmolar CM (LOCM; 40%) or isosmolar CM (IOCM; 36%); and N-acetylcysteine (20%); 8% used no hydration regimen. While 78% of respondents used ≤100 ml of CM in high-risk patients, 14% used ≤150 ml, and 9% set no volume limit. For 57% of respondents, osmolality was the most important attribute in choosing an iodinated CM in at-risk patients; 41% agreed that CIN risk is lower with IOCM versus LOCM (31% disagreed).

Conclusion: A European radiologist survey identified a need for increased implementation of evidence-based protocols to improve CIN prevention: routine identification of at-risk patients; withdrawal of nephrotoxic drugs; use of volume repletion regimens; lowest possible volume of CM; and appropriate CM.  相似文献   

18.
Purpose: To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department.

Material and Methods: IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector.

Results: A dose reduction from 41.8 Gycm2 to 31.5 Gycm2 was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm2 was achieved using the flat panel detector.

Conclusion: The introduction of the flat panel detectors made a considerable dose reduction possible.  相似文献   

19.
Background: Cerebral infarction is usually due to arterial occlusion. Prompt treatment with thrombolytic drugs can restore blood flow and improve recovery from an infarct.

Purpose: To evaluate the clinical efficacy and safety of local intraarterial thrombolysis with recombinant tissue-type plasminogen activator (rtPA) in patients with acute middle cerebral artery (MCA) infarctions within 6 hours of the onset of symptoms.

Material and Methods: Sixteen patients (10 females and six males) aged from 42 to 61 years, with acute MCA territory infarcts were selected for treatment with local i.a. rtPA up to 6 hours after the onset of symptoms. Patient selection was based on clinical examination, computed tomography (CT), and digital subtraction angiography (DSA). A clinical evaluation was performed before treatment, at the time of discharge, and 90 days post-procedure on the basis of modified Rankin and NIHSS scores. Controls (n = 16, nine females and seven males) aged from 51 to 70 years were treated only with intravenous anticoagulation using i.v. heparin infusion. The control group was evaluated with multidetector CT (MDCT) angiography performed on entry to the study and at 2-4 hours afterwards.

Results: Eight patients (50%) achieved a modified Rankin score of 2 or less as the primary outcome after 90 days follow-up. The secondary clinical outcome at 90-day follow-up was as follows: NIHSS score ≤1, three (19%) of the patients; NIHSS score ≥50% decrease, nine (56%) of the patients. A recanalization rate of 75% was achieved in 12 of the 16 treated patients, but only 12.5% in two of the 16 patients in the control group. Intracerebral hemorrhage occurred in two (12.5%) of the patients in the treatment group, but in only one patient (6%) in the control group. There were no deaths in the treated group after thrombolysis up to the time of discharge; however, during the 90-day follow-up, two patients died compared to three patients in the control group (19% vs. 12.5% mortality rate).

Conclusion: Patients with cerebral infarction who were treated within 6 hours of onset using intraarterial rtPA thrombolysis had a significantly improved clinical outcome 90 days after the procedure compared to patients treated only with intravenous anticoagulation.  相似文献   

20.
Purpose: To retrospectively evaluate results of selective embolization of the accessory left gastric artery prior to repeated hepatic arterial infusion chemotherapy using a port-catheter system.

Material and Methods: Of 22 patients with unresectable advanced liver cancer who underwent percutaneous implantation of a port-catheter system, an accessory left gastric artery was revealed by arteriography in 16 patients before and in six patients after port-catheter implantation. The right gastric artery was embolized to prevent gastric mucosal lesions in all 22 patients. In addition, the accessory left gastric artery was selectively embolized for the same purpose using from one to six microcoils, which were from 3 to 5 mm in diameter. Within 10 days after implantation, arteriography was performed while contrast material was infused via the port.

Results: Selective embolization of the accessory left gastric artery was successful in all 22 patients. No complication related to embolization of this artery occurred in any patient. A gastrointestinal mucosal lesion developed in only one case during hepatic arterial infusion chemotherapy, but was unrelated to the accessory left gastric artery.

Conclusion: Prophylactic embolization of the accessory left gastric artery is useful to avoid development of a gastrointestinal mucosal lesion resulting from hepatic arterial infusion chemotherapy.  相似文献   