首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Possible involvement of cell membrane ion transport systems in the uptake and extrusion of Tc-99m-MIBI was investigated by using various buffers with or without Na+ and Ca++, and ion transport inhibitors in a tumor cell line. The ion transport modulators dimethyl amiloride (DMA), verapamil, flunarizine and monensin were used. The uptake of Tc-99m-MIBI was significantly increased in all buffers containing either Na+ or Ca++ alone or none of them. There was significantly increased uptake of Tc-99m-MIBI especially in buffers without Na+. Verapamil, a L-type Ca++ channel blocker, increased Tc-99m-MIBI uptake in all buffers. Flunarizine, which inhibits Na+/ Ca++ channels, caused significantly increased accumulation of Tc-99m-MIBI only in buffer containing both Na+ and Ca++. Monensin, a sodium ionophore, significantly increased uptake of Tc-99m-MIBI. DMA, a potent Na+/H+ antiport inhibitor, significantly inhibited the uptake of Tc-99m-MIBI in all buffers. In conclusion, Tc-99m-MIBI behaves like Na+ during its uptake and extrusion. Extrusion of Tc-99m-MIBI may involve both verapamil- and flunarizine-sensitive pathways.  相似文献   

2.
The uptake characteristics of technetium-99m hexakis-2-methoxyisobutylisonitrile (MIBI), 99mTc-tetrofosmin and 99mTc-furifosmin in human soft tissue sarcoma cell lines were investigated and compared. After 10-120 min of incubation at 37 degrees C, 32 degrees C and 22 degrees C with 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-furifosmin, the kinetics of cellular uptake of these tracers in human soft tissue sarcoma cells SW 684 (fibrosarcoma), SW 872 (liposarcoma), SW 982 (synovial sarcoma) and SW 1353 (chondrosarcoma) was assessed. The uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-furifosmin was temperature dependent. The kinetics of uptake of 99mTc-MIBI and of 99mTc-tetrofosmin was similar between fibrosarcoma and liposarcoma cells, as well as between synovial sarcoma and chondrosarcoma cells. 99mTc-furifosmin showed similar uptake kinetics in all cell lines. The uptake of 99mTc-furifosmin was, however, significantly higher in liposarcoma than in the other cells. The data indicate that the cellular uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-furifosmin is dependent on cellular metabolic activity.  相似文献   

3.
The kinetics and cellular uptake of 99mTc-2-hexakis 2-methoxyiso-butyl-isonitrile (MIBI) and 99mTc-1 ,2-bis[bis(2-ethoxyethyl)phosphino]ethane (tetrofosmin) into malignant versus nonmalignant human breast cell lines were investigated and compared. METHODS: At specific intervals after incubation at 37 degrees C and 22 degrees C with 99mTc-MIBI or 99mTc-tetrofosmin, the uptake characteristics of radiotracers into human adenocarcinoma breast cell lines MCF-7 and SK-BR-3 and human breast, nontumor cell line HBL-100 were assessed. RESULTS: The uptake of 99mTc-MIBI and 99mTc-tetrofosmin was lower at an incubation temperature of 22 degrees C than that at 37 degrees C in the 3 cell lines. In MCF-7 and in SK-BR-3 cells the uptake of 99mTc-MIBI was significantly higher than the uptake of 99mTc-tetrofosmin. The uptake of 99mTc-MIBI was significantly higher into MCF-7 and SK-BR-3 cells than that into HBL-100 cells. In comparison with HBL-100 cells, uptake of 99mTc-tetrofosmin into SK-BR-3 cells was significantly higher, whereas uptake into MCF-7 cells was similar. CONCLUSION: In vitro data suggest that 99mTc-MIBI may be a better tracer than 99mTc-tetrofosmin for discrimination between malignant and nonmalignant breast disease.  相似文献   

4.
Myocellular kinetics of 201Tl, 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order 99mTc-MIBI ==> 99mTc-tetrofosmin ==> 99mTc-furifosmin. 201Tl and 99mTc-MIBI exhibited bi- (t1,t2), 99mTc-tetrofosmin and 99mTc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from 201Tl (t2) ==> 99mTc-MIBI (t2) ==> 99mTc-tetrofosmin (t3) ==> 99mTc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but 99mTc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of 201Tl, and suggests a similar phenomenon for 99mTc-MIBI and 99mTc-tetrofosmin.  相似文献   

5.
The aim of this study was to assess the diagnostic value of technetium-99m-tetrofosmin and technetium-99m-MIBI in a head-to-head comparison. Both radiopharmaceuticals are routinely used for detecting breast cancer. In a prospective, open, diagnostic trial, the two radiopharmaceuticals were administered randomly on different days to the same 101 women suffering from 103 breast tumours. Planar images and single photon emission computer tomography (SPET) were performed. After histological examination of the tumours, sensitivity, specificity and positive and negative predictive value were compared. 99mTc-tetrofosmin and 99mTc-MIBI showed low sensitivity in planar images (44% vs 46%, respectively). SPET improved sensitivity (70% vs 69%, respectively). Specificity in planar images was 83% and 87%, and it was even lower using SPET (70% vs 78%, respectively). Positive predictive value in planar images was 76% vs 81%, and it was not changed by SPET. Negative predictive value was low in planar images (54% vs 57%, respectively), but it was improved by using SPET (65% vs 67%, respectively). In conclusion, 99mTc-tetrofosmin and 99mTc-MIBI scintigraphy show similar diagnostic value in assessing suspicious breast lesions.  相似文献   

6.
99mTc-tetrofosmin, Thallium-201-chloride (201Tl) and 99mTc-MIBI imagings were performed in a patient with malignant thymoma. Tracer uptake in the primary tumor was demonstrated. The tumor-to-background ratios of planar and SPECT imagings were 1.60 and 1.98 for 99mTc-tetrofosmin, 1.12 and 2.09 for 201Tl, and 1.19 and 1.80 for 99mTc-MIBI, respectively. In another patient 99mTc-tetrofosmin and 201Tl imagings were performed. Not only the primary tumor but also the direct invasions and metastatic lesions (bone metastases) were clearly detected. The tumor-to-background ratios of planar and SPECT imagings were 2.31 and 2.78 for 99mTc-tetrofosmin and 2.45 and 3.58 for 201Tl, respectively. In 99mTc-tetrofosmin scintigraphy we acquired delayed images, and the tumor-to-background ratios of planar and SPECT delayed images were 1.20 and 1.86, the retention ratios were -1.11 and -0.92 and the retention indices were -48.1 and -33.1, respectively. Our preliminary results suggest that 99mTc-tetrofosmin is useful in detecting not only the primary tumor but also metastatic lesions from malignant thymoma.  相似文献   

7.
微波照射对小鼠海马细胞膜ATPase活性和离子通道的影响   总被引:7,自引:1,他引:6  
目的从电生理、酶学角度探讨微波照射对海马细胞的影响机理。方法用 2 4 5 0MHz连续波照射理疗机为照射源 ,以小白鼠为对象 ,观察微波照射强度为 1 0mW /cm2 时小鼠海马细胞膜Na+,K+ AT Pase、Ca2 +,Mg2 + ATPase活性、电压门控型Na+、K+、Ca2 +通道的变化情况 ,分别用组织化学染色法和膜片钳方法测定ATPase活性和离子通道功能。结果 1 )照射组海马Na+,K+ ATPase活性与对照组无显著差别 ,Ca2 +,Mg2 + ATPase活性比对照组显著降低 (P <0 .0 5 ) ;2 )照射组静息电位未发生显著变化 ,电压门控型Na+、K+、Ca2 +电流的诱导发生率显著地低于对照组 ,Na+电流峰值所在膜电位向去极化方向偏移 ,Na+电流衰减速率减慢 ,A电流的发生率显著低于对照。结论 2 4 5 0MHz微波照射小鼠 ,在 1 0mW /cm2 时 ,细胞的生存不会受影响 ,但海马细胞膜Ca2 +,Mg2 + ATPase活性受到抑制 ,电压门控型Na+、K+、Ca2 +离子通道受到损害 ,有可能影响学习记忆功能  相似文献   

8.
Our previous studies showed that the efflux rate of technetium-99m methoxyisobutylisonitrile (MIBI) is directly correlated to P-glycoprotein (Pgp) levels in breast carcinoma. The aim of this study was to test whether the Pgp-dependent efflux of 99mTc-MIBI is related to the apoptotic pathway activation in breast carcinoma. Thirty-three untreated non-consecutive patients were intravenously injected with 740 MBq 99mTc-MIBI and serial images were obtained up to 4 h. The rate of efflux was determined by mono-exponential fitting of decay-corrected time-activity curves. Tumour specimens were then obtained at surgery and processed for the determination of the apoptotic index by in situ end-labelling of DNA fragments (Tunel). The rate of tumour cell proliferation was also determined using Ki67 monoclonal antibody. All breast carcinomas showed focal uptake of 99mTc-MIBI and the time to half clearance varied between 85 and 574 min. The apoptotic index ranged between 0.3% and 4.2%, whereas the rate of proliferation varied between 13% and 40%. We found a positive and significant correlation between the apoptotic index and the rate of proliferation (r=0.79, P<0.0001). The efflux rate of 99mTc-MIBI was directly and significantly correlated with the apoptotic index (r=0.74, P<0.0001) and with the rate of proliferation (r=0.58, P<0.001). After partial correlation analysis, only the apoptotic index showed a significant correlation with the efflux rate of 99mTc-MIBI (r=0.57, P<0.001). Our findings indicate that enhanced transport activity of Pgp is associated with increased activation of the apoptotic pathway, suggesting that inhibition of Pgp function with specific modulators may be effective in these patients. Furthermore, since mitochondria are central executioners of apoptosis and intracellular sites of 99mTc-MIBI sequestration, a model for the dynamic coupling of Pgp-dependent 99mTc-MIBI efflux and apoptotic pathway activation may be derived.  相似文献   

9.
Technetium-99m-sestamibi (99mTc-MIBI) imaging is a well-established modality in oncologic investigations. The current study aimed to investigate whether any relationship could be found between 99mTc-MIBI uptake and local perfusion in malignant bone and soft-tissue tumours. It also aimed to compare 99mTc-MIBI images with those of technetium-99m-methylene diphosphonate (99mTc-MDP) bone scintigraphy with regard to the activity distribution pattern, intensity and lesion extension. The study group included 24 patients with various bone and soft-tissue tumours. Three-phase bone scintigraphy and 99mTc-MIBI studies were performed within the same week before any surgical and therapeutic intervention. Images were evaluated visually and quantitatively using regions of interest (ROIs) over the lesion and adjacent normal tissue. The 99mTc-MIBI study was positive with varying degrees of uptake (range, 1.4-5.3). The mean 99mTc-MIBI uptake and 99mTc-MDP blood-pool and osseous phase activity ratios were 2.5 +/- 0.5, 2.8 +/- 1.0 and 5.5 +/- 4.0, respectively. The correlation between the 99mTc-MIBI uptake and blood-pool ratios was 0.70 (P<0.05). While activity distribution patterns were in agreement in 99mTc-MIBI and blood-pool images in the majority of cases, 99mTc-MIBI better delineated tumour viability and extension in five cases. In conclusion, 99mTc-MIBI accumulation shows a reasonable correlation with blood-pool uptake assuming the presence of multifactorial mechanisms in addition to local hyperaemia. Better delineation of tumour outlines and cellular activity seems to be an advantage of 99mTc-MIBI scintigraphy which may be helpful in the evaluation of musculoskeletal tumours.  相似文献   

10.
With technetium-99m 2-methoxy-isobutyl-isonitrile (99mTc-MIBI), regional wall thickening in a patient with dilated cardiomyopathy was analyzed by the first component Fourier method. The regional wall thickening was compared with thallium-201 and 99mTc-MIBI SPECT imaging. Thallium-201 SPECT images showed mildly reduced perfusion in the posterior wall and redistribution in the septum, whereas 99mTc-MIBI images showed heterogeneous accumulation around the left ventricular circumference. By means of phase analysis, diffusely decreased wall thickening and discontinuity of percent wall thickening in neighboring segments were observed throughout the left ventricle. Regional wall motion and wall thickening correlated roughly. However, discrepancies between the mechanical function and myocardial perfusion, and discrepancies in regional myocardial perfusion between thallium-201 and 99mTc-MIBI were observed.  相似文献   

11.
目的 观察刨伤性脑损伤(traumatic brain injury,TBI)大鼠脑组织匀浆及线粒体Na+-K+-ATP酶、Ca2+-ATP酶活性、神经细胞内游离Ca2+浓度及脑组织钙调蛋白(CaM)表达的动态变化,探讨脑复合剂脑保护作用的分子生物学机制.方法 建立大鼠TBI模型,分别设立假手术组、TBI组及中药治疗组.中药治疗组给予脑复合剂10 g·kg-1·d-1,假手术组及TBI组给予同等剂量等渗盐水,2次/d,连续7 d.分别于TBI后24 h、72 h、1周等3个时相点处死大鼠,动态定量分析各组大鼠脑组织匀浆及线粒体Na+-K+-ATP酶、Ca2+-ATP酶活性、神经细胞内游离Ca2+浓度及脑组织CaM表达的变化.结果 TBI组各时相点大鼠脑组织匀浆及线粒体Na+-K+-ATP酶、Ca2+-ATP酶活性均明显降低,于TBI后72 h后逐渐恢复,1周时仍明显低于假手术组.中药治疗组大鼠脑组织Na+-K+-ATP酶、Ca2+-ATP酶活性显著增加(P<0.05);TBI组各时相大鼠脑组织神经细胞内游离Ca2+浓度及脑组织CaM表达均有不同程度增高,于伤后24 h达高峰,持续至72 h仍高于假手术组.而中药治疗组各时相大鼠神经细胞内游离Ca2+浓度及脑组织CaM表达明显低于TBI组(P<0.05).结论 脑复合剂的脑保护作用可能与增加脑组织Na+-K+-ATP酶、Ca2+-ATP酶的活性,从而减轻TBI后脑细胞的能量代谢障碍,降低神经细胞内游离Ca2+浓度及脑组织CaM表达,减轻Ca2+超载所导致的继发性脑损伤有关.  相似文献   

12.
The aim of this study was to assess the correlation between technetium-99m methoxyisobutylisonitrile (MIBI) uptake by parathyroid adenomas, oxyphil cell content and volume of the lesions. Thirty-one patients with parathyroid adenomas were evaluated prospectively. Preoperative double-phase 99mTc-MIBI scintigraphy was performed in all patients and tracer uptake by parathyroid lesions was assessed semi-quantitatively employing region of interest ratios to normal adjacent neck areas. Surgical specimens underwent histological evaluation and oxyphil cell content was determined. The intensity of tracer uptake was compared with oxyphil cell content, volume of the lesions and serum levels of calcium and parathormone. 99mTc-MIBI tracer uptake was correlated with oxyphil cell content, volume of parathyroid lesions and the functional status of the parathyroid adenomas. Tracer accumulation in oxyphil cells might partially explain the preferential 99mTc-MIBI retention in parathyroid lesions.  相似文献   

13.
PURPOSE: To address the links between calcium, peroxidation, cell damage and death and the response of the enzymes involved in free radical metabolism, in splenocytes of mice irradiated with gamma-rays. MATERIALS AND METHODS: Splenocytes of Swiss albino mice were irradiated with various doses (0-7 Gy) of gamma-rays (60Co) at a dose-rate of 0.0575 Gy s(-1). Membrane peroxidation and fluidity were determined by the thiobarbituric acid-reactive substances (TBARS) method, and fluorescence polarization of 1,6-diphenyl-1,3,5-hexatriene (DPH), respectively. Apoptosis was analysed by nucleosomal ladder formation and activity of NF-kappaB by electrophoretic mobility shift assay (EMSA). The specific activities of the antioxidant enzymes, lactate dehydrogenase (LDH), levels of nitric oxide (NO*) and glutathione were determined spectrophotometrically. Modulatory effects of Ca2+ were examined at 3 Gy using different concentrations (1, 3 and 5 mM) in the presence or absence of the ionophore A23187. RESULTS: Irradiation of splenocytes resulted in enhanced peroxidative damage. membrane fluidity, apoptosis and DNA binding activity of NF-kappaB. The specific activities of LDH and antioxidant enzymes superoxide dismutase (SOD), DT-diaphorase (DTD), glutathione S-transferase (GST) and levels of glutathione (GSH) and NO* were increased with radiation dose up to 4Gy. Ca2+ augmented the radiation-induced responses. The presence of ionophore A23187 potentiated the modulatory effects of Ca2+. CONCLUSIONS: These findings show that Ca2+ augments radiation damage and is more effective intracellularly. Ca2+, peroxidation, cellular damage and apoptosis are possibly interlinked through signals, as is evident from the increased activity of NF-kappaB and generation of NO*. The enhanced antioxidant status suggests an attempt made by the irradiated cells to maintain their normal functions.  相似文献   

14.
Ca2+、Mg2+对心肌肌球蛋白ATP酶活性的影响   总被引:1,自引:0,他引:1  
目的研究Ca2 +、Mg2 +对心肌肌球蛋白ATP酶活性的影响。方法采用一种简便、快速的方法从心肌组织中提取肌球蛋白 ,根据酶反应ATP分解释放的无机磷含量检测Ca2 +、Mg2 +激活肌球蛋白ATP酶的Km值及最大反应速度Vmax,以及不同浓度的Ca2 +、Mg2 +、pH值对肌球蛋白ATP酶活性的影响。 结果Ca2 +、Mg2 +-肌球蛋白ATP酶Km值为 5 .2 7± 2 .1 0mmol、7.0 4± 2 .0 6mmol,Vmax分别为 :1 .1 0± 0 .1 3μmol·mg- 1 ·min- 1 、0 .61 7± 0 .0 9μmol·mg- 1 ·min- 1 ;Ca2 +较Mg2 +具有较大的酶激活能力 (P <0 .0 1 ) ,但Mg2 +的浓度影响着肌球蛋白ATP酶对Ca2 +的敏感性 ,当Mg2 +浓度大于 6mmol/L时 ,酶对Ca2 +的存在无反应 ;不同的pH值 ,对Mg2 +激活的酶反应影响较小。结论Ca2 +、Mg2 +对肌球蛋白ATP酶的作用机理不同 ,Mg2 +是维系肌球蛋白具有酶活性构象所必需 ,而Ca2 +在肌肉收缩过程中可能主要充当的是信号传导功能及调控功能  相似文献   

15.
OBJECTIVE: 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging quality under resting conditions. METHODS: Sixty patients (mean age 63.8 years +/- 1.25) with known or suspected coronary artery disease but without evidence of rest-ischemia were included. Twenty patients in each group were examined by a two-day-rest-stress protocol using the three 99mTc-labeled tracers. Visual analysis of all images was performed by two experienced physicians blinded with regard to the applied tracer. Regions of interest (ROI) were defined over the heart, lung and whole body only in the rest imaging in order to calculate heart-to-lung, lung-to-whole body-, and heart-to-whole body-ratios. RESULTS: The heart-to-lung ratio was statistically significant higher for 99mTc-cardiospect-MIBI as compared to 99mTc-sestamibi as well as to 99mTc-tetrofosmin. Furthermore, a significantly higher heart-to-lung ratio was found for 99mTc-sestamibi as compared to 99mTc-tetrofosmin. The heart-to-whole body-ratio and the lung-to-whole body-ratio were equivalent between all tracers. Visual analysis revealed only slight differences regarding image quality between all tracers. CONCLUSIONS: ROI analysis surprisingly revealed a significant higher myocardial uptake and consequently a higher heart-to-lung ratio for 99mTc-cardiospect-MIBI. Whether this leads to a better visual image quality has to be evaluated in future studies with larger study populations as well as semiquantitative segmental analysis of the myocardial perfusion images.  相似文献   

16.
The aims of this study were: (a) to define the accuracy of a preoperative parathyroid imaging protocol based on the combination of technetium-99m pertechnetate/technetium-99m methoxyisobutylisonitrile (99mTcO4/ 99mTc-MIBI) scan and neck ultrasound (US) in selecting patients with primary hyperparathyroidism (pHPT) eligible for a limited neck exploration, and (b) to investigate the potential role of the intraoperative gamma probe (IGP) in radio-guided minimally invasive surgery. 99mTcO4/99mTc-MIBI subtraction scan was performed by means of potassium perchlorate administration with the aim of effecting rapid 99mTcO4 wash-out from the thyroid. Minimally invasive surgery using an IGP was commenced some minutes following the injection of a low, 70 MBq, 99mTc-MIBI dose. Intraoperative PTH (i-PTH) was measured. On the basis of preoperative imaging, 21 pHPT consecutive patients were selected for a limited neck dissection. In 18 of them, a single parathyroid adenoma was found at surgery and IGP allowed performance of parathyroidectomy through a small, 2-2.5 cm, skin incision with a relatively short surgical duration (mean 38 min). i-PTH rapidly normalised in all cases. In two patients, a parathyroid carcinoma was diagnosed at surgery; consequently, a wide neck exploration associated with a near-total thyroidectomy was performed. No loco-regional metastatic lesions were found and i-PTH rapidly normalised after carcinoma excision. In one patient, i-PTH remained elevated after removal of the enlarged parathyroid gland which was localised by 99mTcO4/99mTc-MIBI scan and US. A bilateral exploration was needed to remove a contralateral enlarged parathyroid gland. Combined, 99mTcO4/99mTc-MIBI scan and US imaging correctly localised a single parathyroid gland in 20/21 patients (95.2%); thus, this protocol appears to be accurate enough for the preoperative selection of pHPT patients eligible for limited neck surgery. Moreover, in these selected patients the IGP seems to be helpful in performing radio-guided minimally invasive surgery.  相似文献   

17.
Detectability of metastasis in differentiated thyroid cancer using technetium-99m-methoxyisobutyl isonitrile (99mTc-MIBI) was compared with that of 131I and 201Tl. Forty patients after total thyroidectomy were evaluated. The scan results were compared with those of 131I and 201Tl whole body scintigraphy per patient. The positive rate was 68% in 99mTc-MIBI, 84% in 131I, 60% in 201Tl respectively. As to the lymph node metastasis, the positive rates were 56% in 99mTc-MIBI, 78% in 131I, 39% in 201Tl. In lung metastasis, the positive rate was 46% in 99mTc-MIBI, 82% in 131I and 55% in 201Tl. Serum thyroglobulin (Tg) was significantly higher in 201Tl and/or 99mTc-MIBI positive group compared to that of negative group independent of 131I scan results. Although the detectability of both 99mTc-MIBI and 201Tl were inferior to that of 131I, 9 to 22% of metastasis were detected only by these radiopharmaceuticals. Both 99mTc-MIBI and 201Tl, therefore, should be used in cases with high serum Tg even with negative 131I uptake. Basing on the fact there was no prominent difference between 99mTc-MIBI and 201Tl in the detectability of metastasis, 99mTc-MIBI might be more suitable tracer because of better quality image.  相似文献   

18.
The purpose of this study was to investigate the relationship between technetium-99m hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) accumulation in tumours and response to radiotherapy in non-small cell lung cancer patients in comparison with the findings obtained using thallium-201 chloride (201Tl). Simultaneous dual single-photon emission tomography (SPET) imaging with 600 MBq 99mTc-MIBI and 111 MBq 201Tl was performed in 31 patients with biopsy- or sputum cytology-proven lung cancer. SPET images were acquired 15 min (early) and 2 h (delayed) after injection, and the early ratio, delayed ratio and retention index were measured. The tumours were classified into two groups on the basis of follow-up computed tomography (CT): responders (at least 50% reduction in tumour size) and non-responders (little or no change in tumour size). The mean (+/-SD) values of early ratio, delayed ratio and retention index using 99mTc-MIBI SPET were 3.0+/-1.1, 2.7+/-1.0 and -9.5+/-12.7, respectively, in responders and 2.4+/-0.7, 2.0+/-0.5 and -18.4+/-9.0, respectively, in non-responders. The corresponding values using 201Tl chloride SPET were 3.7+/-1.0, 4.7+/-1.5 and 24.2+/-22.1 in responders and 3.3+/-1.2, 4.0+/-1.3 and 20.4+/-20.5 in nonresponders. Using 99mTc-MIBI, the delayed ratio and retention index in responders were significantly higher than those in non-responders (P<0.01 and P<0.05, respectively). The results of this study indicate that patients with higher delayed ratio and retention index values using 99mTc-MIBI SPET are likely to respond better to radiotherapy than those with lower values. 99mTc-MIBI SPET may give an indication of the short-term response to radiotherapy in patients with non-small cell lung cancer.  相似文献   

19.
The purpose of this investigation was to compare the efficiency of two different imaging protocols using two different clinically available 99mTc labelled myocardial perfusion tracers. One thousand one hundred and thirty-four imaging studies were performed prospectively, using either 99mTc-tetrofosmin or 99mTc-sestamibi, alternating the use of each tracer for a total period of 8 months. 99mTc-tetrofosmin rest studies were performed with injections of 259MBq-370MBq and imaging 30 min later. Exercise studies were performed with injections of 777MBq-1.11GBq and imaging 20 min later. 99mTc-sestamibi studies used doses similar to those in the 99mTc-tetrofosmin studies. Imaging followed a standard procedure, at 60 min after rest injection, and 30 min after exercise. For patients undergoing pharmacological stress testing99mTc-sestamibi was imaged 45 min after injection and 99mTc-tetrofosmin was imaged 30 min after injection. Variables analysed were (1) injection-to-imaging time for the procedure, and (2) the number of repeated scans because of extra cardiac activity. The completion time for the rest study was significantly shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (47.7+/-21.7 min vs 74.3+/-25.8 min P<0.0001). Likewise, the total study time was shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (90+/-32.7 min vs 124+/-37 min, P<0.0001). More importantly, the number of repeated scans was higher with 99mTc-sestamibi compared to 99mTc-tetrofosmin, 21.4% vs 10%, P=0.001 for rest studies and 16.4% vs 7.9% P=0.001 [corrected] for rest and stress. It was concluded that, using a same day rest/stress protocol, 99mTc-tetrofosmin provided higher patient throughput with fewer repeat scans. These factors may be considered for efficiency improvement in nuclear cardiology laboratories using 99mTc perfusion tracers.  相似文献   

20.
To determine whether technetium-99m hexakis-2-methoxy isobutyl isonitrile (99mTc-MIBI) myocardial scintigraphy is a superior method in the detection of coronary artery disease, exercise and rest 99mTc-MIBI planar and SPECT scintigraphy were performed on 27 patients with coronary artery disease. When 99mTc-MIBI (555 MBq (15 mCi)) was injected, first-pass radionuclide angiography (FPRNA) was simultaneously performed by a new mobile multicrystal gamma camera (SIM-400), and LV function (LVEF) was evaluated quantitatively. Visual semiquantitative detection of coronary lesions using 99mTc-MIBI images showed superior accuracy to that obtained using 201TlCl images. 99mTc-MIBI SPECT images were particularly useful in diagnosing LCX and RCA lesions. Moreover, the simultaneous assessment of perfusion and left ventricular function by 99mTc-MIBI FPRNA proved to be useful in the diagnosis of multi-vessel disease. In summary, 99mTc-MIBI SPECT scintigraphy with simultaneous assessment of left ventricular function showed better diagnostic accuracy than 201TlCl myocardial scintigraphy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号