 共查询到20条相似文献,搜索用时 48 毫秒
1.
The present study was undertaken to examine the temporal relationship between exercise and QT interval shortening as one of the principal determinants for the functioning of QT pacemakers. Ten patients (mean age of 72.6 years) with implanted QT pacemakers were subjected to supine bicycle exercise with two different slopes, 90% and 80%. The QT interval as seen by the pacemaker was monitored by telemetry and stored on magnetic tape. After the beginning of exercise QT prolongation of a few msec occurred up to 40 sec in most patients. The earliest QT shortening of 4 msec was noted after 63.4 sec with 90% slope and 75.7 sec with 80% slope. The difference was not significant. The further time course was dependent on slope and pacemaker algorithm. Maximal QT shortening was 65.9 msec with 90% and 69.8 msec with 80% slope. It was seen 29.2 sec after termination of exercise with 90% slope and 69.5 sec with 80% slope (P < 0.05). There was no correlation of the measured delays with age. Earliest rate response in QT driven pacemakers is determined by earliest QT shortening on one hand and by the slope setting of the pacemaker on the other, where the limiting parameter appears to be QT shortening, which occurs after the first minute of exercise.  相似文献   

2.
The QT pacemaker is a rate modulated pacemaker that uses the evoked QT interval as an indicator to determine its optimal pacing rate. Despite the generally favorable clinical results with this form of pacing, some flaws in the system have been reported, such as the frequently observed rather slow initial response of the pacing rate to physical exercise, and the phenomenon of oscillation of the heart rate. These problems can be attributed to the rate adaptive algorithm used in the current QT pacemaker. Recently, in a reexamination of the relationship between evoked QT interval and pacing rate, a curvilinear relationship between these parameters has been demonstrated. As a result, a new algorithm has been developed for the next generation of the QT pacemaker. Before this new algorithm was implemented in new implantable devices, it was evaluated in a multicenter clinical investigation, with emphasis on the initial response of the pacing rate to exercise. This study was carried out by means of special software in the programmer of the QT pacemaker. By employing real-time bidirectional telemetry, it was possible to submit the study population, consisting of 37 patients with implanted QT pacemakers of the current generation, to identical exercise tests. Comparing these exercise tests, it appears that a considerable gain in speed of response to exercise can be achieved by using the same sensor with a faster reacting, nonlinear rate adaptive algorithm.  相似文献   

3.
It has been shown that alterations in QT/RR relationship may be associated with arrhythmogenesis in several clinical settings. In the present study the QT/RR relationship was studied in 20 patients with idiopathic ventricular tachycardia (12 men and 8 women, aged 41±14 years) compared to 20 normal subjects (9 men and 11 women, aged 39 ± 13 years). All the patients were off any antiarrhythmic drugs and had no evidence of intraventricular conduction defects. The QT intervals and their preceding RR intervals were measured on electrocardiogram strips from 24-hour Holter tapes at hourly intervals. The differences in the maximum, minimum, and mean of either the QT interval or its corrected values between patients with idiopathic ventricular tachycardia and normal subjects were not statistically significant. There was a significant correlation between the QT and RR intervals in normal subjects (γ= 0.73 ± 0.12, P < 0.05) and in patients with idiopathic ventricular tachycardia (γ= 0.80 ± 0.10, P < 0.05). However, the linear regression line of the QT interval against the RR interval were significantly (P < 0.001) altered in patients with idiopathic ventricular tachycardia (QT = 0.24 + 0.18 RR) compared to normal subjects (QT = 0.27 ± 0.12 RR). We conclude that although there is no significant change in the QT interval and its corrected values, the QT/RR relationship is significantly altered in patients with idiopathic ventricular tachycardia as compared to normal subjects. This may be of importance in the pathogenesis of idiopathic ventricular tachycardia in these patients.  相似文献   

4.
A case of QT duration dependent T wave oversensing mimicking QRS undersensing and pacemaker malfunction is presented. This example indicates that interpretation of pacemaker ECG may be difficult, even in case of WI pacemaker.  相似文献   

5.
Polymorphic ventricular tachycardia (PVT) is a form of ventricular tachycardia characterized by QRS complexes that seem to change direction during the tachycardia. If associated with a prolonged QT interval, it is called torsades de pointes. In the absence of a congenital long QT syndrome, torsades is seen with certain drugs such as antiarrhythmic agents (Class IA, IC, III), psychotropic medications, antidepressants, antihistamines, and electrolyte disturbances. We report the first case of polymorphic ventricular tachycardia with normal QT interval associated with the oral use of levofloxacin in the absence of other etiologies known to cause these arrhythmias.  相似文献   

6.
The Topaz model 515 (Vitatron B.V.) is a dual sensor rate responsive pacemaker for single chamber stimulation. It can be driven by activity counts (ACT) and QT interval measurements. Inappropriate rate modulation due to one sensor can be corrected by "sensor cross-checking." It was implanted in ten patients (20-86 years) of whom seven had complete heart block and atrial arrhythmias. After implantation T-wave amplitude ranged from 0.9mV-3.5 mV. T-wave sensing ranged from 88%–99% in 9/10 patients at the follow-up of 3 weeks. Eight patients remained in default setting of the activity threshold, after evaluation with a short walking test. An exercise test was performed on all patients. In one test, QT sensing was marginal because of lead implantation in the right ventricular outflow tract. Therefore, this pacing rate was only modulated by ACT sensing. All others were tested with equal contribution of information from both sensors (ACT = QT). In 7/9, rate response was satisfactory. When the treadmill was repeated with ACT in five of these seven patients, rate generally accelerated too fast. In one patient the setting was adjusted to "QT > ACT," because of inappropriate acceleration due to activity sensing, in another it was adjusted to "QT < ACT" because of delayed response to activity. The pacing rate and the ACT during treadmill tests in "QT = ACT" mode were more closely correlated in the first 3 minutes, compared with the last 3 minutes. We feel that rate modulation with this new pacemaker is adequate. Sensor blending and sensor cross-checking are of clinical importance.  相似文献   

7.
Long QT Syndrome is a cardiac disorder caused by an abnormal prolongation of the ventricular repolarization phase. The primary concern in this syndrome is the propensity towards polymorphic ventricular tachycardia and sudden cardiac death. This article presents several cases, highlighting the pathophysiology, clinical presentation, and management of this disorder.  相似文献   

8.
A 65-year-old man, treated with the QT sensing rate responsive pacemaker required to manage high degree AV block, sustained a transmural inferior wall myocardial infarction 6 months after the pacemaker implant. The rate response of the pacemaker during the acute phase of the infarction was physiological as evidenced by increased pacing rate during pain and with the gradual decrease in rate during the first postinfarction days. The underlying mechanisms are discussed.  相似文献   

9.
LANDMAN, M.A.J., ET AL.: Initial Clinical Experience with Rate Adaptive Cardiac Pacing Using Two Sensors Simultaneously. In the rate adaptive pacemakers, all presently available sensors show one or more drawbacks. Combining two sensors in a single pacemaker, we tried to optimize its rate responsive characteristics. In this study, we present the rate adaptive behavior of a two sensor pacemaker system, using both QT interval and activity sensing. In addition, we compared the rate response with that of each sensor alone. Nine patients with an implanted QT interval sensing pacemaker, and an externally attached activity sensing pacemaker performed three exercise stress tests on treadmill. The QT interval, measured by the implanted pacemaker, and the activity level, were transmitted to an external computer. This computer contained the two sensor rate adaptive algorithm, and reprogrammed the implanted pacemaker on beat-to-beat basis. Conclusion: In the two sensor mode the rate increases immediately at the onset of exercise, caused by the prompt response of the activity sensor. Further rate increase is driven by the QT interval sensor and therefore proportional to the level of exercise. Furthermore, the rate decay during the recovery phase is more physiological.  相似文献   

10.
A 63-year-old woman treated with a QT sensing rate responsive pacemaker following aortic valve replacement developed late subacute bacterial endocarditis. During febrile periods, associated with systemic upset, pacing was physiological as evidenced by an increased heart rate during pyrexia and a decrease when afebrile.  相似文献   

11.
The atrioventricular (AV) interval is critical in dual chamber (DDD) pacing in patients with hypertrophic obstructive cardiomyopathy (HOCM) to obtain full ventricular capture (FVC) with maximal reduction of the left ventricular (LV) outflow gradient and optimal LV diastolic filling. We studied the relationship of FVC, fusion, spontaneous AV conduction, and the QT interval. Methods: 11 patients with various cardiac diseases and stable AV conduction received a QT sensing Diamond (tm) Vitatron, DDD pacemaker. Software was downloaded into the pacemaker. In the DDD pacing mode, with the QT interval measured from the ventricular pacing stimulus to the end of the T wave, the AV interval was shortened from 400 ms, in 20-ms steps, to 90 ms. At 90 ms the stimulation rate was increased by 30 beats/mm and the AV interval was increased stepwise. FVC and fusion was examined on the surface ECG, Results: At 400 ms interval, spontaneous AV conduction inhibited the pacemaker. Shortening the AV interval resulted in pacing with a short QT interval. Further reduction of the AV interval resulted in a longer QT interval up to a point where the QT interval became stable. This point, the bending point in the plot of measured QT interval versus shortened AV intervals, coincided with the point of FVC. The relation of the QT-AV interval plot and the point of fusion was comparable when lengthening the AV interval at a 30 beats/mm faster stimulation rate. Conclusion: The bending point in the QT interval versus AV interval plots showed a good correlation with the FVC and fusion points observed on ECG. The results suggest that automatic discrimination between fusion and full capture using QT interval measurements may be feasible.  相似文献   

12.
Significant prolongation of the QT interval in pediatric patients with cardiomyopathy is rare. We report two cases of dilated myopathy with transient and dramatic QT prolongation. Both had associated ventricular arrhythmias, with one having torsade de pointes, and the other nonsustained ventricular tachycardia. Normalization of their QTc occurred as their ventricular function improved.  相似文献   

13.
We have evaluated clinically a rate-responsive pacemaker which uses the evoked QT principle as indicator of physiological demand. This pacemaker is microprocessor-based and fully programmable noninvasively through radiofrequency coupling to an external microcomputer. To date this system has been implanted in 15 patients. With this QT sensing pacemaker the rate response to exercise was smooth and progressive, and gradually returned to the basic paced rate after termination of activity. Physiologic rate responsive pacing resulted in significant improvement in exercise tolerance and a 40% increase in cardiac output when compared to fixed-rate pacing in 8 patients. This initial experience confirms the possibility of obtaining a physiological response to exercise using a pacing system dependent only on a unipolar electrode which is independent of the problems of atrial activity and sensing. Rate responsive pacing might prove to be a useful alternative to atrial synchronous systems, and particularly advantageous in those patients whose sinoatrial function is abnormal or who suffer from atrial arrhythmias.  相似文献   

14.
To assess beat-to-beat behavior of QT interval under different conditions, high resolution recordings and computerized beat-to-beat analysis of the electrocardiogram were performed at rest, during recovery after short exercise, and during atrial pacing. Beat-to-beat variations of QT interval during sinus rhythm at rest and after short exercise were measured in ten healthy men. In an additional three patients with supraventricular tachycardia, beat-to-beat QT changes were studied after abrupt sustained acceleration and deceleration of heart rate by atrial pacing. Beat-to-beat changes in RH interval at rest are followed by minimal changes of the QT interval. The measured proportional change of the QT interval compared with the change in HR interval (Δ QT/A BR) was 0.02. This value represents 10% of the value expected for QT changes from Bazett's formula. Following short exercise QT interval did not change for 15 seconds and reached a maximal value 30 seconds later as compared to the RR interval (192 vs 115 sees, P < 0.001). The steady state of the QT interval during sustained atrial pacing was achieved after 132, 135, and 133 seconds for pacing intervals of 600, 500, and 600 msec, respectively. Our data indicate a relatively slow adaptation of the QT interval to changes in heart rate.  相似文献   

15.
This report describes a fetus presenting with intrauterine tachycardia and hydrops fetalis. Soon after birth the neonate was noted to be in torsades de pointes that responded dramatically to medical management. Long QT syndrome (LQTS) was diagnosed on electrocardiogram obtained soon after birth. The prognosis is poor when LQTS presents in utero or during the first week of life. However, our infant did well with medical management and has remained free of arrhythmias at follow-up.  相似文献   

16.
The effects of sensor selection and sensor blending on the cardiovascular response to graded exercise was evaluated in 10 patients (age 74 ± 2 yrs; 7 men and 3 women) implanted with a dual sensor rate adaptive VVIR pacemaker (Vitatron Topaz(tm) model 515). Patients underwent three graded exercise tests (GXT) with sensor programming randomly assigned. For a given graded exercise text the pacemaker was programmed into activity sensing (ACT), QT sensing, or dual sensing (ACT = QT). Data were recorded at rest and during each stage of the graded exercise text. Oxygen uptake (VO2) was measured continuously using a Q Plex I system. Heart rate (HR), stroke volume (SV), and cardiac output (Qc) were measured by impedance cardiography. Systolic time intervals were calculated from simultaneous recordings of the ECG. phonocardiogram, and the impedance cardiogram. In response to the GXT no differences in peak VO2 were observed across the three sensor settings. Regardless of the sensor setting Qc increased linearly with each increment in VO2. The HR response to ACT only pacing was significantly higher than in the other two pacing conditions. During ACT only pacing SV failed to rise in response to exercise. The increased exercise Qc during QT and ACT = QT pacing were mediated by significant increases in both HR and SV. The QT and dual pacing conditions were also associated with longer diastolic filling times. The data indicate that the mechanisms responsible for the increase Qc during exercise were different for ACT versus ACT = QT or QT sensor-driven pacing.  相似文献   

17.
Introduction of an Automatic QT Interval Driven Rate Responsive Pacemaker   总被引:1,自引:0,他引:1  
QT driven rate responsive pacemakers have been implanted since 1981. The more than 6 years experience and additional knowledge gained during several clinical studies have culminated in the design of an automatic rate responsive pacemaker. The adjustment of the rate responsive function to each individual patient is carried out automatically by the pacemaker, which therefore performs several measurements both at rest and during exercise. The results of these measurements are used to adapt the rate responsive parameters in order to optimize the rate response, even under changing circumstances.  相似文献   

18.
Changes in the QT and QTc intervals in 19 patients were studied at a ventricular paced rate difference of 50 beats/min. In all patients the measured QT interval shortened as the pacing rate was increased, from a mean value of 441 ms to 380 ms (p < 0.001), but when correct ed for heart rate the QTc- lengthened from a mean value of 518 ms to 575 ms. In 11 patients the QT in terval was measured at rest and immediately following exercise sufficient to increase the atrial rate by approximately 50 beats/min at identical ventricular paced rates. In all patients exercise-induced QT interval shortening from a mean value of 433 ms to 399 ms (p < 0.001). These results show first that Bazett's formula is unsuitable for correction of QT interval changes induced by ventricular pacing, and second that heart rate and changes in sympathetic tone independently influence the duration of the QT interval. It is suggested that these resuits are relevant to the design of physiological pacemakers in which the duration of the QT interval influences the discharge frequency of the pacemaker and to the consideration of ventricular pacing for the treatment of abnormal repolarization syndromes. (PACE, Vol. 5, May-June, 1982)  相似文献   

19.
The QT interval in patients with catecholaminergic polymorphic ventricular tachycardia (CPVT) is typically normal. However, CPVT patients are sometimes misdiagnosed as concealed long QT syndrome (LQTS), because patients with LQTS also manifest with syncope or sudden death following periods of exertion or extreme emotion. We report a CPVT patient with a pathogenic RyR2 mutation associated with a marked QT prolongation, which normalized after flecainide therapy.  相似文献   

20.
A patient with long QT syndrome was treated with beta blockers and had a permanent DDD pacemaker implanted. The lower rate was set to 85 beats/min because this provided the best shortening of QT interval at the lowest paced heart rate. The atrioventricular (AV) delay was programmed to 250 msec to allow native AV conduction. Patient returned complaining of symptoms suggestive of pacemaker syndrome. ECG during one of these episodes showed AV sequential pacing. Doppler echocardiography of hepatic vein flow suggested atrial contraction against a closed tricuspid valve. Endocardial electrogram telemetry demonstrated ventriculoatrial (VA) conduction with the retrograde atrial electrogram falling within the atrial refractory period and thus was not sensed. The following atrial stimulus did not capture because of the atrial refractoriness. Ventricular pacing proceeded after the programmed AV delay. Reprogramming the AV delay to 200 msec restored AV synchrony by allowing the atrial stimulus to capture by placing it outside of the refractory period of the atrium. No further symptoms reported during six months of follow-up.  相似文献   