Direct-aperture optimization (DAO) was applied to iterative beam-orientation selection in intensity-modulated radiation therapy (IMRT), so as to ensure a realistic segmental treatment plan at each iteration. Nested optimization engines dealt separately with gantry angles, couch angles, collimator angles, segment shapes, segment weights and wedge angles. Each optimization engine performed a random search with successively narrowing step sizes. For optimization of segment shapes, the filtered backprojection (FBP) method was first used to determine desired fluence, the fluence map was segmented, and then constrained direct-aperture optimization was used thereafter. Segment shapes were fully optimized when a beam angle was perturbed, and minimally re-optimized otherwise. The algorithm was compared with a previously reported method using FBP alone at each orientation iteration. An example case consisting of a cylindrical phantom with a hemi-annular planning target volume (PTV) showed that for three-field plans, the method performed better than when using FBP alone, but for five or more fields, neither method provided much benefit over equally spaced beams. For a prostate case, improved bladder sparing was achieved through the use of the new algorithm. A plan for partial scalp treatment showed slightly improved PTV coverage and lower irradiated volume of brain with the new method compared to FBP alone. It is concluded that, although the method is computationally intensive and not suitable for searching large unconstrained regions of beam space, it can be used effectively in conjunction with prior class solutions to provide individually optimized IMRT treatment plans.  相似文献   

2.
In intensity-modulated radiation therapy (IMRT), the incident beam orientations are often determined by a trial and error search. The conventional beam's-eye view (BEV) tool becomes less helpful in IMRT because it is frequently required that beams go through organs at risk (OARs) in order to achieve a compromise between the dosimetric objectives of the planning target volume (PTV) and the OARs. In this paper, we report a beam's-eye view dosimetrics (BEVD) technique to assist in the selection of beam orientations in IMRT. In our method, each beam portal is divided into a grid of beamlets. A score function is introduced to measure the 'goodness' of each beamlet at a given gantry angle. The score is determined by the maximum PTV dose deliverable by the beamlet without exceeding the tolerance doses of the OARs and normal tissue located in the path of the beamlet. The overall score of the gantry angle is given by a sum of the scores of all beamlets. For a given patient. the score function is evaluated for each possible beam orientation. The directions with the highest scores are then selected as the candidates for beam placement. This procedure is similar to the BEV approach used in conventional radiation therapy, except that the evaluation by a human is replaced by a score function to take into account the intensity modulation. This technique allows one to select beam orientations without the excessive computing overhead of computer optimization of beam orientation. It also provides useful insight into the problem of selection of beam orientation and is especially valuable for complicated cases where the PTV is surrounded by several sensitive structures and where it is difficult to select a set of 'good' beam orientations. Several two-dimensional (2D) model cases were used to test the proposed technique. The plans obtained using the BEVD-selected beam orientations were compared with the plans obtained using equiangular spaced beams. For all the model cases investigated, the use of BEVD-selected beam orientations improved the dose distributions significantly. These examples indicate that the technique has considerable potential for simplifying the IMRT treatment planning process and allows for better utilization of the technical capacity of IMRT.  相似文献   

3.
Schulz RJ  Kagan AR 《Medical physics》2002,29(7):1473-1482
Physicists are critical members of the radiation therapy team, and rightfully so. Therefore, it is not unreasonable that they be acquainted with the broader aspects of the management of patients who receive radiation treatments, as well as the roles played by surgeons, medical oncologists and other members of the treatment team. The spate of recent technical developments openly embraced by medical physicists, many of whom appear unconcerned by questionable benefits and very high costs, leads the authors to believe that this acquaintance is not as widespread as it should be. The present paper provides a brief review of clinical considerations in radiation oncology, statistics for the most prevalent cancers, and how those cancers that account for over 90% of mortality are currently treated. With these data as background, it then considers the extent to which one of the more widely promoted new technologies is likely to impact upon survival. By providing this modicum of perspective, physicists will be in a better position to evaluate these new technologies in more fundamental clinical terms, and thereby enhance their contributions to the overall care of the cancer patient.  相似文献   

4.
A common way to solve intensity-modulated radiation therapy (IMRT) optimization problems is to use a beamlet-based approach. The approach is usually employed in a three-step manner: first a beamlet-weight optimization problem is solved, then the fluence profiles are converted into step-and-shoot segments, and finally postoptimization of the segment weights is performed. A drawback of beamlet-based approaches is that beamlet-weight optimization problems are ill-conditioned and have to be regularized in order to produce smooth fluence profiles that are suitable for conversion. The purpose of this paper is twofold: first, to explain the suitability of solving beamlet-based IMRT problems by a BFGS quasi-Newton sequential quadratic programming method with diagonal initial Hessian estimate, and second, to empirically show that beamlet-weight optimization problems should be solved in relatively few iterations when using this optimization method. The explanation of the suitability is based on viewing the optimization method as an iterative regularization method. In iterative regularization, the optimization problem is solved approximately by iterating long enough to obtain a solution close to the optimal one, but terminating before too much noise occurs. Iterative regularization requires an optimization method that initially proceeds in smooth directions and makes rapid initial progress. Solving ten beamlet-based IMRT problems with dose-volume objectives and bounds on the beamlet-weights, we find that the considered optimization method fulfills the requirements for performing iterative regularization. After segment-weight optimization, the treatments obtained using 35 beamlet-weight iterations outperform the treatments obtained using 100 beamlet-weight iterations, both in terms of objective value and of target uniformity. We conclude that iterating too long may in fact deteriorate the quality of the deliverable plan.  相似文献   

5.
IMRT treatment planning via biological objectives gives rise to constrained nonlinear optimization problems. We consider formulations with nonlinear objectives based on the equivalent uniform dose (EUD), with bound constraints on the beamlet weights, and describe fast, flexible variants of the two-metric gradient-projection approach for solving them efficiently and in a mathematically sound manner. We conclude that an approach that calculates the Newton component of the step iteratively, by means of the conjugate-gradient algorithm and an implicit representation of the Hessian matrix, is most effective. We also present an efficient heuristic for obtaining an approximate solution with a smoother distribution of beamlet weights. The effectiveness of the methods is verified by testing on a medium-scale clinical case.  相似文献   

6.
In this study, we perform a scientific comparative analysis of using (60)Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and (60)Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered (60)Co beams and (iii) a helical tomotherapy (60)Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H&N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H&N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and (60)Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant (60)Co beams, yet were marginal above 9 beams for H&N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical (60)Co beam geometry achieved similar plan quality as static plans with 11 equidistant (60)Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and (60)Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target coverage for 18 MV. For plans with comparable target coverage, critical structure sparing was best achieved with 6 MV beams followed closely by (60)Co beams, with 18 MV beams requiring significantly increased dose to critical structures. In this paper, we report in detail on a representative set of results from these experiments. The results of the investigation demonstrate the potential for IMRT radiotherapy employing commercially available (60)Co sources and a double-focused MLC. Increasing the number of equidistant beams beyond 9 was not observed to significantly improve target coverage or critical organ sparing and static plans were found to produce comparable plans to those obtained using a helical tomotherapy treatment delivery when optimized using the same well-tuned convex FMO model. While previous studies have shown that 18 MV plans are equivalent to 6 MV for prostate IMRT, we found that the 18 MV beams actually required more fluence to provide similar quality target coverage.  相似文献   

7.
8.
调强放射治疗剂量验证工具与方法   总被引:3,自引:0,他引:3  
调强放射治疗广泛应用于肿瘤的治疗,其剂量分布在三维方向上与靶区高度适形.然而调强放疗的复杂射野、数据误差、算法误差及机器误差等因素可能会引起较大的剂量偏差,从而造成实际剂量与计划剂量不符,而严重的剂量不符可能会造成不必要的辐射事故.因此鉴于患者安全角度考虑,治疗计划在执行之前通常需要进行剂量验证,以确保患者治疗计划的安全实施,避免计划外的剂量照射.目前,临床上剂量验证的工具与方法有很多,包括指形电离室工具和热释光剂量仪工具等的点剂量验证法、半导体阵列工具和电离室阵列工具以及胶片工具等的二维剂量验证法、ArcCHECK工具和Delta4工具以及第三方软件工具等的三维剂量验证法等,对临床上常见的剂量验证工具和方法进行了综述.  相似文献   

9.
Intensity-modulated photon-electron radiation therapy (IMPERT) takes advantage of the high conformity of photon intensity-modulated radiation therapy (IMRT) and low distal dose of electrons to reduce the total energy delivered to healthy tissue, potentially reducing serious side effects including secondary malignancies. This theoretical study was undertaken to elucidate basic principles of IMPERT planning and to help quantify the advantage of IMPERT over photon IMRT. Plans using 6 MV x-rays alone (IMRT) or in combination with 6-21 MeV electron beams (IMPERT) were developed for digital cylindrical water phantoms that included an organ at risk (OAR) situated 0.25 cm below a 5 cm thick planning target volume (PTV), with the top of the PTV positioned up to 4 cm below the surface. Electron beam energy and percentage dose contribution of the electron beam to the total dose were investigated with a flat-bottom PTV. The effect of target shape was investigated with a concave- or convex-bottom PTV positioned at the surface. Air or bone cavities were embedded in the PTV to investigate the effect of tissue inhomogeneity. Dose variations in the electron dose distribution due to tissue inhomogeneity were accurately calculated with Monte Carlo simulation. The preferred electron dose contribution was approximately 50% of the total dose. For all the PTV-OAR scenarios, IMPERT was able to achieve comparable PTV coverage and OAR sparing as IMRT while reducing the energy deposited to the healthy tissue by 6-25%. The IMPERT technique is a clinically viable approach for reducing serious side effects in radiotherapy.  相似文献   

10.
Shuttling multileaf collimators (SMLCs) can increase the MU efficiency of intensity-modulated radiation therapy compared with the multiple-static-field (MSF-MLC) technique or dynamic MLC (DMLC) technique with conventional MLCs. In a previous paper (Phys. Med. Biol. 45 3343-58) a particular SMLC was shown, for highly modulated intensity distributions, to increase the MU efficiency compared with the MSF-MLC technique. In this companion paper, two new arrangements similar to that described in the earlier paper, but with less mechanical complexity, are shown to be constructionally simpler but less MU efficient. Additionally another new concept of SMLC is shown which also increases the MU efficiency compared with the MSF-MLC technique and often improves the MU efficiency compared with the previously reported SMLC for highly modulated intensity distributions. It also leads to zero tongue-and-groove underdose in the direction orthogonal to that of the shuttling elements (so-called across-the-rows).  相似文献   

11.
The increased beam-on times which characterize intensity-modulated radiation therapy (IMRT) could lead to an increase in the dose received by radiation therapists due to induced activity. To examine this, gamma ray spectrometry was used to identify the major isotopes responsible for activation at a representative location in the treatment room of an 18 MV accelerator (Varian Clinac 21EX). These were found to be 28Al, 56Mn, and 24Na. The decay of the dose rate measured at this location following irradiation was analyzed in terms of the known half-lives to yield saturation dose rates of 9.6, 12.4, and 6.2 microSv/h, respectively. A formalism was developed to estimate activation dose (microSv/week) due to successive patient irradiation cycles, characterized by the number of 18 MV fractions per week, F, the number of MU per fraction, M, the in-room time between fractions, td (min), and the treatment delivery time t'r (min). The results are represented by the sum of two formulas, one for the dose from 28Al 1.8 x 10(-3) F M (1-e(-03t'(r))/t'r and one for the dose from the other isotopes approximately 1.1 x 10(-6) F(1.7) Mt(d). For conventional therapy doses are about 60 microSv/week for an 18 MV workload of 60,000 MU/week. Irradiation for QA purposes can significantly increase the dose. For IMRT as currently practiced, lengthy treatment delivery times limit the number of fractions that can be delivered per week and hence limit the dose to values similar to those in conventional therapy. However for an IMRT regime designed to maximize patient throughput, doses up to 330 microSv/week could be expected. To reduce dose it is recommended that IMRT treatments should be delivered at energies lower than 18 MV, that in multienergy IMRT, high-energy treatments should be scheduled in the latter part of the day, and that equipment manufacturers should strive to minimize activation in the design of high-energy accelerators.  相似文献   

12.
13.
目的:探讨SunCHECK软件在调强放疗计划剂量验证中的应用。方法:选取新疆医科大学第一附属医院已执行IMRT计划的40例患者,应用SunCHECK软件,对所接受数据进行单独计算,然后对原始放疗计划和QA计划进行Gamma分析。最后对QA计划与ArcCHECK测量结果进行Gamma通过率比较。结果:在SunCHECK软件单独计算结果中,Monaco计划平均Gamma通过率略高于Eclipse计划。相同计划系统原始计划与QA计划Gamma通过率没有差异。使用SunCHECK软件计算QA计划(包括Monaco计划和Eclipse计划)Gamma通过率略高于ArcCHECK测量结果的Gamma通过率。结论:SunCHECK软件符合IMRT计划剂量验证需要,给放疗质控工作带来了很大的便利性。无论是作为单独放疗计划验算工具,还是以log日志文件反推进行计划验证,都应该把SunCHECK作为质量保证程序的一部分。  相似文献   

14.
We propose and study a unified model for handling dose constraints (physical dose, equivalent uniform dose (EUD), etc) and radiation source constraints in a single mathematical framework based on the split feasibility problem. The model does not impose on the constraints an exogenous objective (merit) function. The optimization algorithm minimizes a weighted proximity function that measures the sum of the squares of the distances to the constraint sets. This guarantees convergence to a feasible solution point if the split feasibility problem is consistent (i.e., has a solution), or, otherwise, convergence to a solution that minimally violates the physical dose constraints and EUD constraints. We present computational results that demonstrate the validity of the model and the power of the proposed algorithmic scheme.  相似文献   

15.
16.
Arc-modulated radiation therapy (AMRT) is a novel rotational intensity-modulated radiation therapy (IMRT) technique developed for a clinical linear accelerator that aims to deliver highly conformal radiation treatment using just one arc of gantry rotation. Compared to fixed-gantry IMRT and the multiple-arc intensity-modulated arc therapy (IMAT) techniques, AMRT promises the same treatment quality with a single-arc delivery. In this paper, we present a treatment planning scheme for AMRT, which addresses the challenges in inverse planning, leaf sequencing and dose calculation. The feasibility and performance of this AMRT treatment planning scheme have been verified with multiple clinical cases of various sites on Varian linear accelerators.  相似文献   

17.
A new type of polymer gel dosimeter, which responds well to absorbed dose even when manufactured in the presence of normal levels of oxygen, was recently described by Fong et al. [Phys. Med. Biol. 46, 3105-3113 (2001)] and referred to by the acronym MAGIC. The aim of this study was to investigate the feasibility of using this new type of gel for intensity-modulated radiation therapy (IMRT) verification. Gel manufacturing was carried out in room atmosphere under normal levels of oxygen. IMRT inverse treatment planning was performed using the Helios software. The gel was irradiated using a linear accelerator equipped with a dynamic multileaf collimator, and intensity modulation was achieved using sliding window technique. The response to absorbed dose was evaluated using magnetic resonance imaging. Measured and calculated dose distributions were compared with regard to in-plane isodoses and dose volume histograms. In addition, the spatial and dosimetric accuracy was evaluated using the gamma formalism. Good agreement between calculated and measured data was obtained. In the isocenter plane, the 70% and 90% isodoses acquired using the different methods are mostly within 2 mm, with up to 3 mm disagreement at isolated points. For the planning target volume (PTV), the calculated mean relative dose was 96.8 +/- 2.5% (1 SD) and the measured relative mean dose was 98.6 +/- 2.2%. Corresponding data for an organ at risk was 34.4 +/- 0.9% and 32.7 +/- 0.7%, respectively. The gamma criterion (3 mm spatial/3% dose deviation) was fulfilled for 94% of the pixels in the target region. Discrepancies were found in hot spots the upper and lower parts of the PTV, where the measured dose was up to 11% higher than calculated. This was attributed to sub optimal scatter kernels used in the treatment planning system dose calculations. Our results indicate great potential for IMRT verification using MAGIC-type polymer gel.  相似文献   

18.
In inverse planning for intensity-modulated radiotherapy (IMRT), the fluence distribution of each treatment beam is usually calculated in an optimization process. The delivery of the resulting treatment plan using multileaf collimators (MLCs) is performed either in the step-and-shoot or sliding window technique. For step-and-shoot delivery, the arbitrary beam fluence distributions have to be transformed into an applicable sequence of subsegments. In a stratification step the complexity of the fluence maps is reduced by assigning each beamlet to discrete intensity values, followed by the sequencing step that generates the subsegments. In this work, we concentrate on the stratification for step-and-shoot delivery. Different concepts of stratification are formally introduced. In addition to already used strategies that minimize the difference between original and stratified beam intensities, we propose an original stratification principle that minimizes the error of the resulting dose distribution. It could be shown that for a comparable total number of subsegments the dose-oriented stratification results in a better approximation of the original, unsequenced plan. The presented algorithm can replace the stratification routine in existing sequencer programs and can also be applied to interpolated plans that are generated in an interactive decision making process of multicriteria inverse planning programs.  相似文献   

19.
A novel, anatomic beam orientation optimization (A-BOO) algorithm is proposed to significantly improve conventional intensity-modulated radiation therapy (IMRT). The A-BOO algorithm vectorially analyses polygonal surface mesh data of contoured patient anatomy. Five optimal (5-opt) deliverable beam orientations are selected based on (1) tangential orientation bisecting the target and adjacent organ's-at-risk (OARs) to produce precipitous dose gradients between them and (2) parallel incidence with polygon features of the target volume to facilitate conformal coverage. The 5-opt plans were compared to standard five, seven, and nine equiangular-spaced beam plans (5-equi, 7-equi, 9-equi) for: (1) gastric, (2) Radiation Therapy Oncology Group (RTOG) P-0126 prostate, and (3) RTOG H-0022 oropharyngeal (stage-III, IV) cancer patients. In the gastric case, the noncoplanar 5-opt plan reduced the right kidney V 20 Gy by 32.2%, 23.2%, and 20.6% compared to plans with five, seven, and nine equiangular-spaced beams. In the prostate case, the coplanar 5-opt plan produced similar rectal sparing as the 7-equi and 9-equi plans with a reduction of the V 75, V 70, V 65, and V 60 Gy of 2.4%, 5.3%, 7.0%, and 9.5% compared to the 5-equi plan. In the stage-III and IV oropharyngeal cases, the noncoplanar 5-opt plan substantially reduced the V 30 Gy and mean dose to the contralateral parotid compared to plans with five, seven, and nine equiangular-spaced beams: (stage-III) 7.1%, 5.2%, 6.8%, and 5.1, 3.5, 3.7 Gy and (stage-IV) 10.2%, 10.2%, 9.8% and 7.0, 7.1, 7.2 Gy. The geometry-based A-BOO algorithm has been demonstrated to be robust for application to a variety of IMRT treatment sites. Beam orientations producing significant improvements in OAR sparing over conventional IMRT can be automatically produced in minutes compared to hours with existing dose-based beam orientation optimization methods.  相似文献   

20.
The purpose of this study is to extend an algorithm proposed for beam orientation optimization in classical conformal radiotherapy to intensity-modulated radiation therapy (IMRT) and to evaluate the algorithm's performance in IMRT scenarios. In addition, the effect of the candidate pool of beam orientations, in terms of beam orientation resolution and starting orientation, on the optimized beam configuration, plan quality and optimization time is also explored. The algorithm is based on the technique of mixed integer linear programming in which binary and positive float variables are employed to represent candidates for beam orientation and beamlet weights in beam intensity maps. Both beam orientations and beam intensity maps are simultaneously optimized in the algorithm with a deterministic method. Several different clinical cases were used to test the algorithm and the results show that both target coverage and critical structures sparing were significantly improved for the plans with optimized beam orientations compared to those with equi-spaced beam orientations. The calculation time was less than an hour for the cases with 36 binary variables on a PC with a Pentium IV 2.66 GHz processor. It is also found that decreasing beam orientation resolution to 10 degrees greatly reduced the size of the candidate pool of beam orientations without significant influence on the optimized beam configuration and plan quality, while selecting different starting orientations had large influence. Our study demonstrates that the algorithm can be applied to IMRT scenarios, and better beam orientation configurations can be obtained using this algorithm. Furthermore, the optimization efficiency can be greatly increased through proper selection of beam orientation resolution and starting beam orientation while guaranteeing the optimized beam configurations and plan quality.  相似文献   