首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective was to evaluate whether the echogenicity of focal liver lesions (FLLs) on baseline gray-scale ultrasound (US) interferes with the diagnostic performance of contrast-enhanced US (CEUS) for small FLLs. Three-hundred and eighty-eight patients were examined by real-time CEUS using a sulfur hexafluoride-filled microbubble contrast agent. The images of 114 hyperechoic lesions, 30 isoechoic lesions and 244 hypoechoic lesions were reviewed by two blinded independent readers. A five-point confidence level was used to discriminate malignant from benign lesions, and specific diagnoses were made. The diagnostic performances were evaluated by receiver-operating characteristic (ROC) analysis. The diagnostic performances of CEUS on hyperechoic lesions in terms of the areas (Az) under the ROC curve were 0.987 (reader 1) and 0.981 (reader 2), and were 0.987 (reader 1) and 0.984 (reader 2) for iso- and hypoechoic lesions, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 87.0–95.9%, 93.1–100%, 88.6–100%, 70.0–97.1% and 90.0–95.1%, respectively. The echogenicity of FLLs on baseline gray-scale US does not appear to interfere with the diagnostic ability of CEUS for small FLLs.  相似文献   

2.

Objective

To retrospectively determine the accuracy of baseline ultrasound (BUS) and of contrast-enhanced ultrasound (CEUS) in the differential diagnosis of pancreatic solid-cystic lesions.

Methods

Fifty-four pancreatic solid-cystic lesions in 52 patients were examined with BUS and CEUS, two different seniority radiologists read the images independently, Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic value of BUS and CEUS in the diagnosis of benign or malignant pancreatic solid-cystic lesions, the diagnostic consistency between different seniority radiologists was evaluated by Kappa statistics.

Results

Among the 54 lesions, there were pancreatic cyst five cases, pancreatic pseudocyst twenty cases, pancreatic cystadenoma eight cases, pancreatic cystadenocarcinoma seven cases, intraductal papillary mucinous neoplasm of pancreas (IPMN) three cases, pancreatic carcinoma combined liquefied six cases, solid-pseudopallary tumor of pancreas (SPTP) three cases, pancreatic myopericytoma one case, pancreatic lymphangioma one case. After ROC analysis, the areas under the ROC curve (Az) were 0.752 by BUS, 0.928 by CEUS to resident radiologist, and 0.896 by BUS, 0.954 by CEUS to staff radiologist. The correct diagnosis rate of specific disease was 42.6% by BUS, 64.8% by CEUS to staff radiologist (P < 0.05), and 33.3% by BUS, 53.7% by CEUS to resident radiologist (P < 0.05). The interobserver agreement in CEUS is higher than that in BUS, the Kappa value was 0.889 ± 0.062 and 0.428 ± 0.126 respectively.

Conclusion

Compared with BUS, CEUS can significantly enhance the diagnostic rate of pancreatic solid-cystic lesions.  相似文献   

3.
Jin KN  Lee JM  Kim SH  Shin KS  Lee JY  Han JK  Choi BI 《European radiology》2006,16(10):2284-2291
The purpose of this study was to determine whether multiplanar reconstruction (MPR) images can improve the accuracy of MDCT-based colorectal cancer preoperative staging by receiver-operating characteristic (ROC) analysis. Fifty-five patients with colorectal cancer underwent contrast-enhanced CT colonography using an 8- or 16-row scanner. Two separate interval reviews of the axial MDCT datasets with/without MPR images (coronal and sagittal) were performed independently by two radiologists blinded to both the colonoscopic and histopathologic results. At each review session, the radiologists were asked to determine the colorectal cancer TNM stage within the context of differentiating ≤T3 from T4, N0 from ≥N1 and M0 from M1 using a five-point confidence scale. The radiologists’ performance for staging the colorectal cancer using axial CT datasets with/without MPR images was evaluated using ROC analysis. Sensitivities, specificities and interobserver agreement were assessed. When MPR images were added, significant improvement was achieved by both radiologists for differentiating N0 from ≥N1 in terms of both AZ (0.651 to 0.769; 0.573 to 0.713) and specificity (26.7 to 69.2%; 23.1 to 76.9%) (P<0.05). For T staging, ROC analysis failed to show a significant improvement in terms of differentiating ≤T3 from T4 for either radiologist (P>0.05), but a significant improvement in the specificity (70 to 90%; 80 to 92%) was achieved by one radiologist (P<0.05). In terms of the M staging, a significant improvement in the Az (0.844 to 0.996) was observed for the combined interpretation of the axial and MPR images by one radiologist (P<0.05). Furthermore, substantial or almost perfect interobserver agreement was achieved for all TNM stagings for the combined interpretations (κ=0.641–0.866), whereas only fair to substantial agreement was achieved for the axial images alone (κ=0.337-0.707). In conclusion, the combined interpretation of the axial and MPR MDCT images significantly improved the local staging of colorectal cancer compared with assessments based on axial images alone.  相似文献   

4.
The value of a computer-aided detection tool (CAD) as second reader in combination with experienced and inexperienced radiologists for the diagnosis of acute pulmonary embolism (PE) was assessed prospectively. Computed tomographic angiography (CTA) scans (64 × 0.6 mm collimation; 61.4 mm/rot table feed) of 56 patients (31 women, 34–89 years, mean = 66 years) with suspected PE were analysed by two experienced (R1, R2) and two inexperienced (R3, R4) radiologists for the presence and distribution of emboli using a five-point confidence rating, and by CAD. Informed consent was obtained from all patients. Results were compared with an independent reference standard. Inter-observer agreement was calculated by kappa, confidence assessed by ROC analysis. A total of 1,116 emboli [within mediastinal (n = 72), lobar (n = 133), segmental (n = 465) and subsegmental arteries (n = 455)] were included. CAD detected 343 emboli (sensitivity = 30.74%, correct-positive rate = 6.13/patient; false-positive rate = 4.1/patient). Inter-observer agreement was good (R1, R2: κ = 0.84, 95% CI = 0.81–0.87; R3, R4: κ = 0.79, 95% CI = 0.76–0.81). Extended inter-observer agreement was higher in mediastinal and lobar than in segmental and subsegmental arteries (κ = 0.84–0.86 and κ = 0.51–0.58 for mediastinal/lobar and segmental/subsegmental arteries, respectively P < 0.05). Agreement between experienced and inexperienced readers was improved by CAD (κ = 0.60–0.62 and κ = 0.69–0.72 before and after CAD consensus, respectively P < 0.05). The experienced outperformed the inexperienced readers (Az = 0.95, 0.93, 0.89 and 0.86 for R1–4, respectively, P < 0.05). CAD significantly improved overall performances of readers 3 and 4 (Az = 0.86 for R3, R4 and Az = 0.89 for R3, R4 with CAD, P < 0.05), by enhancing sensitivities in segmental/subsegmental arteries. CAD improved experienced readers’ sensitivities in segmental/subsegmental arteries (sens. = 0.93 and 0.90 for R1, R2 before and 0.97 and 0.94 for R1, R2 after CAD consensus, P < 0.05), without significant improvement of their overall performances (P > 0.05). Particularly inexperienced readers benefit from consensus with CAD data, greatly improving detection of segmental and subsegmental emboli. This system is advocated as a second reader.  相似文献   

5.
Objective  The aim of our study was to determine the role of the operator’s experience in the sonographic evaluation of the painful shoulder and to validate assumptions about its technical performance in routine practice. Materials and methods  Two radiologists, respectively standard and expert sonographic operators, independently and prospectively scanned 65 patients with clinical suspicion of rotator cuff lesion. Magnetic resonance arthrography was the reference standard. Results  The sensitivity of the expert ultrasound operator was 95.3% for full-thickness rotator cuff tears (41/43), 70.6% for partial-thickness tears (12/17), 64.3% for intratendinous tears (9/14), 100% for abnormality of the long head of biceps tendon (seven of seven), 88.9% for supraspinatus tendinosis (16/18), 96.4% for subacromial bursa abnormalities (53/55), and 91.7% for acromioclavicular joint osteoarthritis (33/36). The two sonographic operators were in very good agreement about full-thickness rotator cuff tears (κ = 0.90), supraspinatus tendinosis (κ = 0.80), abnormalities of the long head of biceps tendon (κ = 0.84), subacromial bursa abnormalities (κ = 0.89), and acromioclavicular osteoarthritis (κ = 0.81). The agreement was only moderate for partial-thickness tears (κ = 0.63) and intratendinous tears (κ = 0.57). Conclusions  Our results show that in moderately experienced hands as in experts’ hands, sonography has a low level of interobserver variability for full-thickness rotator cuff tears. Considering partial-thickness and intratendinous rotator cuff tears, our data suggest that interobserver variability is higher.  相似文献   

6.
Aim: The aim of this study was to compare contrast-enhanced ultrasonography (CEUS) to baseline US and contrast-enhanced computed tomography (CT) in metastatic disease of the liver diagnosed or suspected by US during presurgical staging or postsurgical follow-up for primary malignancies. Materials and methods: Two hundred-fifty-three patients considered suitable for US due to the complete explorability of the liver and with one to five proven or suspected liver metastases at baseline US were included. All patients underwent US before and after microbubble injection, and multiphase contrast-enhanced CT. Independent panels of readers reviewed US and CT scans and recorded liver metastases according to a 5-grade scale of diagnostic confidence. Sensitivity, specificity (diagnostic performance) and area under the receiver operating characteristics (ROC) curve (diagnostic confidence) were calculated. Results: Reference standards revealed no metastases in 57/253, more than five in 59/253, and one to five in 137/253 patients. In patients with one to five metastases, CEUS versus baseline US revealed more metastases in 64/137 and the same number in 73/137 patients while CEUS versus CT revealed more metastases in 10/137, the same number in 99/137, and lower number in 28/137. Sensitivity, specificity, and area under ROC curve of CEUS (83%, 84%, 0.929, respectively) differed from baseline US (40%, 63%, 0.579, respectively; P<0.01) while did not differ from CT (89%, 89%, 0.945, respectively; P>0.05). Conclusion: CEUS improved liver metastases diagnosis in comparison with baseline US while it revealed similar diagnostic performance and confidence to contrast-enhanced CT in patients considered suitable for US and with proven or suspected liver metastases at baseline US.  相似文献   

7.
The purpose of the study was to retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance angiography (conventional MRA) with MRA accelerated by a parallel acquisition technique (fast MRA) for the assessment of visceral arteries, using 64-detector-row computed tomography angiography (MDCTA) as the reference standard. Eighteen patients underwent fast MRA (imaging time 17 s), conventional MRA (29 s) and MDCTA of the abdomen and pelvis. Two independent readers assessed subjective image quality and the presence of arterial stenosis. Data were analysed on per-patient and per-segment bases. Fast MRA yielded better subjective image quality in all segments compared with conventional MRA (P = 0.012 for reader 1, P = 0.055 for reader 2) because of fewer motion-induced artefacts. Sensitivity and specificity of fast MRA for the detection of arterial stenosis were 100% for both readers. Sensitivity of conventional MRA was 89% for both readers, and specificity was 100% (reader 1) and 99% (reader 2). Differences in sensitivity between the two types of MRA were not significant for either reader. Interobserver agreement for the detection of arterial stenosis was excellent for fast (κ = 1.00) and good for conventional MRA (κ = 0.76). Thus, subjective image quality of visceral arteries remains good on fast MRA compared with conventional MRA, and the two techniques do not differ substantially in the grading of arterial stenosis, despite the markedly reduced acquisition time of fast MRA.  相似文献   

8.
The effectiveness of contrast-enhanced ultrasonography (CEUS) in the evaluation of patients with acute renal infarcts was investigated, using contrast-enhanced helical computed tomography (CT) as the reference imaging procedure. Twenty-seven consecutive patients with acute renal infarcts detected with contrast-enhanced helical CT underwent CEUS. Digital cine-clips of CEUS were evaluated by two independent readers blinded to CT findings. Image quality was rated subjectively on a four-point scale. Then, readers were asked to assign a confidence level in diagnosis of renal infarct at the upper pole, medium portion, and lower pole of each kidney according to a five-degree scale, ranging from definitely absent to definitely present. ROC curve analysis was employed to assess the overall confidence of diagnosis of infarct, and weighted kappa values were calculated to assess inter-reader agreement. The subjective image quality of CEUS was lower than the image quality of CT at the upper poles. However, the diagnostic performance of CEUS was excellent (area under receiver-operator characteristic curve 0.992 ± 0.006 for reader 1; 0.991 ± 0.007 for reader 2), with very good inter-reader agreement (weighted kappa value = 0.83). CEUS is a reproducible tool to detect acute renal infarcts in men, with a diagnostic performance approaching that of CT. This study was presented as a scientific paper for ECR 2007 (control number: 3596)  相似文献   

9.
The purpose was to compare two-dimensional (2D) magnetic resonance pancreatography (MRP) with 3D MRP to evaluate intraductal papillary mucinous neoplasm (IPMN). Thirty-four patients (22 men, 12 women; age range, 45–80 years) with IPMN (n = 40) were examined with MRP on 2D and 3D sequences. Two readers independently reviewed the images to assess the overall image quality, artifacts, lesion location, communication with main pancreatic duct, and potential for malignancy. The readers assigned their confidence level (1–5) for predicting ductal communication of the lesion. The results of MRP were compared with endoscopic retrograde pancreatography and surgical and histopathologic findings. Studies obtained with 3D MRP were of significantly higher technical quality than those obtained with 2D MRP. Although 3D MRP showed higher area under the ROC curve (Az) values for predicting ductal communication of the lesion, there was no statistical significance between Az values of 2D and 3D MRP (Az for 2D = 0.821, 0.864 for readers 1 and 2, respectively, and Az for 3D= 0.964, 0.921). Accuracies for discriminating benign from malignant lesions were 70 and 67.5% (reader 1 and 2, respectively, for 2D) and 62.5 and 80.1% (3D). 3D MRP showed superior image quality to that of 2D MRP but did not increase the diagnostic accuracy for predicting ductal communication of the lesion.  相似文献   

10.

Objective

To prospectively evaluate the diagnostic efficacy of conventional ultrasound (US), contrast-enhanced US (CEUS), the combined use of two modalities, and magnetic resonance imaging (MRI) in the differentiation of focal solid breast lesions.

Materials and methods

61 patients with BI-RADS category 3–5 breast lesions detected at conventional US underwent CEUS and MRI. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of conventional US, CEUS, combination of two modalities and MRI for discrimination between benign and malignant breast lesions.

Results

Tissue specimens of 61 breast lesions were obtained either from surgical resection (n = 46) or from needle biopsy (n = 15). Histopathologic diagnosis revealed 28 benign and 33 malignant lesions. The diagnostic performance of conventional US and CEUS in differentiating benign from malignant breast lesions showed no significant difference (P = 0.741). The combination of two modalities significantly improved the diagnostic accuracy compared with either conventional US or CEUS alone (P = 0.031 and P = 0.012, respectively). The area under the ROC curve (Az) value for the combined use of two modalities for discrimination between benign and malignant breast lesions was 0.94, and that for MRI was 0.91, whereas no statistical difference was found between them (P = 0.296).

Conclusion

The combined use of conventional US and CEUS has a better diagnostic performance than either method alone and displays good agreement with MRI in the differentiation capability for benign and malignant breast lesions.  相似文献   

11.
The purpose of this study was to compare the value of pelvic ultrasound with color Doppler and magnetic resonance imaging (MRI) in: (1) the diagnosis of placental adhesive disorders (PADs), (2) the definition of the degree of placenta invasiveness, (3) determining the topographic correlation between the diagnostic images and the surgical results. Fifty patients in the third trimester of pregnancy with a diagnosis of placenta previa and at least one previous caesarean section underwent color Doppler ultrasound (US) and MRI. The sonographic and MRI diagnoses were compared with the final pathologic or operative findings. Outcomes at delivery were as follows: normal placenta (n = 38) and PAD (n = 12). MR and US Doppler showed no statistically difference in identiyfing patients with PAD (P = 0.74), while MRI was statistically better than US Doppler in evaluating the depth of placenta infiltration (P < 0.001). MRI accurately characterized the topography of invasion in 12/12 (100%) of the cases, while US accurately characterized the topography of invasion in 9/12 (75%) of the cases. In conclusion, we confirmed that pelvic US is highly reliable to diagnose or exclude the presence of PAD and found MRI to be an excellent tool for the staging and topographic evaluation of PAD.  相似文献   

12.
The purpose of this study was to retrospectively evaluate the use of US elastography in the differentiation of mammographically detected suspicious microcalcifications, using histology as the reference standard. Between May 2006 and April 2007, real-time US elasticity images were obtained in 77 patients (age range, 24–67 years; mean, 46 years) with 77 mammographically detected areas of microcalcifications (42 benign and 35 malignant lesions) prior to needle biopsy. Two experienced radiologists reviewed cine clips of elasticity and B-mode images and assigned an elasticity score of 1 to 3 in consensus, based on the degree of strain in the hypoechoic lesion without information of mammography and histology. For the elasticity score, the mean ± standard deviation was 1.5 ± 0.7 for benign and 2.7 ± 0.7 for malignant lesions (P < 0.001). When a cutoff point between elasticity scores of 1 and 2 was used, US elastography showed 97% (34/35) sensitivity, 62% (26/42) specificity, 68% (34/50) PPV, and 96% (26/27) NPV with an Az value of 0.852 (0.753–0.923, 95% confidence interval) in the differentiation of benign and malignant microcalcifications. Our results suggest that US elastography has the potential to differentiate benign and malignant lesions associated with microcalcifications detected at screening mammography.  相似文献   

13.

Aim

To describe the typical CEUS pattern of pancreatic lesions and to evaluate the diagnostic accuracy of Contrast-enhanced ultrasound (CEUS) in their characterization.

Materials and methods

All US and CEUS examinations of focal pancreatic masses performed in six centers during a period of five years were reviewed. Inclusion criteria were: focal pancreatic mass pathologically proved, visible at ultrasound (US) and studied with CEUS. All lesions were then evaluated for size, aspect and enhancement pattern. Sensitivity, specificity, positive and negative predictive values with 95% CIs were calculated to define diagnostic accuracy of CEUS in respect to pathology. Diagnostic confidence of US and CEUS, discerning between benign and malignant lesions, were represented by using ROC (receiver operating characteristics) curves. Agreement was evaluated by means of k statistics.

Results

1439 pancreatic lesions were included. At CEUS the lesions were divided into solid (89%) and cystic (12%) masses and classified into six and eight categories, respectively. Among the solid lesions, adenocarcinomas were characterized with an accuracy of 87.8%. Among the cystic lesions, cystic tumors were diagnosed with an accuracy of 97.1%. ROC curve area increased from 0.637 for US to 0.877 for CEUS (p < 0.0001). Inter-observer agreement was slightly higher for solid (k = 0.78) than cystic (k = 0.62) lesions. In none of the centers side effects were reported.

Conclusion

CEUS is accurate in the characterization of pancreatic lesions. CEUS should be considered as a complementary imaging method for pancreatic lesions characterization.  相似文献   

14.
We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 ± 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer’s values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 ± 0.39 mm versus 2.49 ± 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 ± 6.2 mm, correlating well with CT (18.5 ± 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 ± 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA. Philipp A. Kaufmann was supported by a grant from the Swiss National Science Foundation (SNSF-professorship grant No. PP00A-68835). Hatem Alkadhi and Lotus Desbiolles were supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions (NCCR CO-ME) of the Swiss National Science Foundation.  相似文献   

15.
RATIONALE AND OBJECTIVES: We sought to evaluate the diagnostic performance of an artificial neural network (ANN) and binary logistic regression (BLR) in differentiating malignant from benign thyroid nodules on ultrasonography. MATERIALS AND METHODS: Two experienced radiologists, who were unaware of the histopathological diagnosis, analyzed ultrasonographic (US) features of 109 pathologically proven thyroid lesions (49 malignant and 60 benign) in 96 patients. Each radiologist was asked to evaluate US findings and categorize nodules into one of the two groups (malignant vs. benign) in each case. The following 8 US parameters were assessed for each nodule: size, shape, margin, echogenicity, cystic change, microcalcification, macrocalcification, and halo sign. Statistically significant US findings were obtained with backward stepwise logistic regression and were used for training and testing of the ANN and the BLR. The performance of the ANN and BLR was compared to that of the radiologists using receiver-operating characteristic (ROC) analysis. RESULTS: Statistically significant US findings were size, margin, echogenicity, cystic change, and macrocalcification of the nodules. The area under the ROC curve (Az) values of ANN and BLR were 0.9492 +/- 0.0195 and 0.9046 +/- 0.0289, respectively. The Az value was 0.8300 +/- 0.0359 for reader 1 and 0.7600 +/- 0.0409 for reader 2. The Az values for ANN and BLR were significantly higher than those for both radiologists (all p < .05). CONCLUSION: The performance of the ANN and the BLR was better than that of the radiologists in the distinction of benign and malignant thyroid nodules.  相似文献   

16.
Introduction  This study was aimed to investigate the relationship between quantitative proton magnetic resonance spectroscopy (1H-MRS) and pathological changes in meningioma. Materials and methods  Twenty-two meningioma cases underwent single voxel 1H-MRS (point-resolved spectroscopy sequence, repetition time/echo time = 2,000 ms/68, 136, 272 ms). Absolute choline (Cho) concentration was calculated using tissue water as the internal reference and corrected according to intra-voxel cystic/necrotic parts. Pathological specimens were stained with MIB-1 antibody to measure cell density and proliferation index. Correlation analysis was performed between absolute Cho concentration and cell density and MIB-1 labeled proliferation index. Results  Average Cho concentration of all meningiomas before correction was 2.95 ± 0.86 mmol/kg wet weight. It was increased to 3.23 ± 1.15 mmol/kg wet weight after correction. Average cell density of all meningiomas was 333 ± 119 cells/HPF, and average proliferation index was 2.93 ± 5.72%. A linear, positive correlation between cell density and Cho concentration was observed (r = 0.650, P = 0.001). After correction of Cho concentration, the correlation became more significant (r = 0.737, P < 0.001). However, no significant correlation between Cho concentration and proliferation index was found. There seemed to be a positive correlation trend after correction of Cho concentration but did not reach significant level. Conclusion  Absolute Cho concentration, especially Cho concentration corrected according to intra-voxel cystic/necrotic parts, reflects cell density of meningioma. Grant: This study was supported by the Japan-China Sasakawa Medical Fellowship (Nippon Foundation, Japan)  相似文献   

17.
To compare the visibility of anatomical details and prostate cancer local staging performance of pelvic phased-array coil and integrated endorectal–pelvic phased-array coil MR imaging, with histologic analysis serving as the reference standard. MR imaging was performed in 81 consecutive patients with biopsy-proved prostate cancer, prior to radical prostatectomy, on a 1.5T scanner. T2-weighted fast spin echo images of the prostate were obtained using phased-array coil and endorectal–pelvic phased-array coils. Prospectively, one radiologist, retrospectively, two radiologists and two less experienced radiologists working in consensus, evaluated and scored all endorectal–pelvic phased-array imaging, with regard to visibility of anatomical details and local staging. Receiver operator characteristics (ROC) analysis was performed. Anatomical details of the overall prostate were significantly better evaluated using the endorectal–pelvic phased-array coil setup (P<0.05). The overall local staging accuracy, sensitivity and specificity for the pelvic phased-array coil was 59% (48/81), 56% (20/36) and 62% (28/45), and for the endorectal-pelvic phased-array coils 83% (67/81), 64% (23/36) and 98% (44/45) respectively, for the prospective reader. Accuracy and specificity were significantly better with endorectal–pelvic phased-array coils (P<0.05). The overall staging accuracy, sensitivity and specificity for the retrospective readers were 78–79% (P<0.05), 56–58% and 96%, for the endorectal–pelvic phased-array coils. Area under the ROC curve (Az) was significantly higher for endorectal–pelvic phased-array coils (Az=0.74) compared to pelvic phased-array coil (Az=0.57), for the prospective reader. The use of endorectal–pelvic phased array coils resulted in significant improvement of anatomic details, extracapsular extension accuracy and specificity. Overstaging is reduced significantly with equal sensitivity when an endorectal–pelvic phased-array coil is used. Financial support: Grant from the Dutch Cancer Society  相似文献   

18.
Our purpose was to identify thin-section chest computed tomography (CT) findings of malignancy other than the presence of a solid portion within ground-glass nodules (GGNs) and to evaluate whether the radiologists’ performance in determining malignancy can be enhanced with this information. The predictive CT findings of malignancy extracted from the CT findings of 80 GGNs (47 malignant, 33 benign) were a size of >8 mm [odds ratio (OR), 10.930; P = 0.045] and a lobulated border (OR, 13.769; P = 0.016) for pure GGNs and a lobulated border (OR, 10.200; P = 0.024) for mixed GGNs. Four chest radiologists and five radiology residents participated in the observer performance study with CT of 130 GGNs (67 malignant, 63 benign). Receiver-operating characteristic (ROC) analysis was used to compare radiologists’ performances before and after providing these predictive findings. For pure GGNs, mean areas under the curve (Az) of all readers without and with CT predictive information were significantly different (0.621 ± 0.052 and 0.766 ± 0.055, P < 0.05). For mixed GGNs, the Az values achieved without and with predictive information were not significantly different (0.727 ± 0.064 and 0.764 ± 0.056, P > 0.05). Information about lesion size and morphological characteristics can enhance radiologists’ performance in determining malignancy of pure GGNs.  相似文献   

19.
Kim MJ  Kim EK  Kwak JY  Son EJ  Youk JH  Choi SH  Han M  Oh KK 《European radiology》2009,19(2):310-317
The aim of this study was to compare the diagnostic accuracy and image quality of microcalcifications in zoomed digital contact mammography with digital magnification mammography. Three radiologists with different levels of experience in mammography reviewed 120 microcalcification clusters in 111 patients with a full-field digital mammography system relying on digital magnification mammogram (MAG) images and zoomed images from contact mammography (ZOOM) using commercially available zooming systems on monitors. Each radiologist estimated the probability of malignancy and rated the image quality and confidence rate. Performance was evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and receiver operating characteristic (ROC) analysis. All three radiologists rated MAG images higher than ZOOM images for sensitivity with statistical significance (average value, 92% vs. 87%, P < 0.05) and performance by ROC analysis improved with MAG imaging. The confidence rate for diagnosis decision and the assessment of lesion characteristics were also better in MAG images than in ZOOM images with statistical significance (P < 0.0001). Digital magnification mammography can enhance diagnostic performance when characterizing microcalcifications. Images zoomed from digital contact mammography cannot serve as an alternative to direct magnification digital mammography. This work was supported by the Korea Research Foundation Grant funded by the Korean Government (MOEHRD) (KRF-2007-313-E00363).  相似文献   

20.
Purpose  Error and variation in reporting remains one of the weakest features of clinical imaging despite enormous technological advances in nuclear medicine and radiology. The aim of this study was to evaluate agreement amongst experienced readers in staging non-small-cell lung cancer (NSCLC) with PET-CT. Methods  A series of 18F-FDG PET-CT scans from 100 consecutive patients were reviewed independently by three experienced readers, with two readers reviewing each scan series a second time. Individual mediastinal lymph node stations were assessed as benign/inflammatory, equivocal or malignant, and AJCC N and M stage were also assigned. Kappa (κ) was used to compare ratings from two categories and weighted kappa (κw) for three or more categories, and kappa values were interpreted according to the Landis-Koch benchmarks. Results  Both intra- and interobserver agreement for N and M staging were high. For M staging there was almost perfect intra- and interobserver agreement (κ = 0.90–0.93). For N staging, agreement was either almost perfect or substantial (intraobserver κw = 0.79, 0.91; interobserver κw = 0.75–0.81). Importantly, there was almost perfect agreement for N0/1 vs N2/3 disease (κ = 0.80–0.97). Agreement for inferior and superior mediastinal nodes (stations 1, 2, 3, 7, 8, 9) was either almost perfect or substantial (κw = 0.71–0.88), but lower for hilar nodes (10; κw = 0.56–0.71). Interreporter variability was greatest for aortopulmonary nodes (5, 6; κw = 0.48–0.55). Conclusion  Amongst experienced reporters in a single centre, there was a very high level of agreement for both mediastinal nodal stage and detection of distant metastases with PET-CT. This supports the use of PET-CT as a robust imaging modality for staging NSCLC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏