首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In all but one of the acrylic bone cement brands used in cemented arthroplasties, N,N-dimethyl-4-toluidine (DMPT) serves as the activator of the polymerization reaction. However, many concerns have been raised about this activator, all related to its toxicity. Thus, various workers have assessed a number of alternative activators, with two examples being N,N-dimethylamino-4-benzyl laurate (DMAL) and N,N-dimethylamino-4-benzyl oleate (DMAO). The results of limited characterization of cements that contain DMAL or DMAO have been reported in the literature. The present work is a comprehensive comparison of cements that contain one of these three activators, in which the values of a large array of their properties were determined. These properties range from the setting time and maximum exotherm temperature of the curing cement to the variation of the loss elastic modulus of the cured cement with frequency of the applied indenting force in dynamic nanoindentation tests. The present results, taken in conjunction with those presented in previous reports by the present authors and co-workers on other properties of these cements, indicate that both DMAL and DMPT are suitable alternatives to DMPT.  相似文献   

2.
Acrylic bone-cement formulations were prepared with the use of a new tertiary aromatic amine derived from oleic acid, and also by incorporating an acrylic monomer derived from the same acid with the aim of reducing the leaching of toxic residuals and improving mechanical properties. 4-N,N dimethylaminobenzyl oleate (DMAO) was used as an activator in the benzoyl-peroxide radical cold curing of polymethyl methacrylate. Cements that contained DMAO exhibited much lower polymerization exotherm values, ranging between 55 and 62 C, with a setting time around 16--17 min, depending on the amine/BPO molar ratio of the formulation. On curing a commercial bone cement, Palacosreg R with DMAO, a decrease of 20 C in peak temperature and an increase in setting time of 7 min were obtained, the curing parameters remaining well within limits permitted by the standards. In a second stage, partial substitution of MMA by oleyloxyethyl methacrylate (OMA) in the acrylic formulations was performed, the polymerization being initiated with the DMAO/BPO redox system. These formulations exhibited longer setting times and lower peak temperatures with respect to those based on PMMA. The glass transition temperature of the experimental cements were lower than that of PMMA cement because of the presence of long aliphatic chains of both activator and monomer in the cement matrix. Number average molecular weights of the cured cements were in the range of 1.2x10(5). PMMA cements cured with DMAO/BPO revealed a significant (p<0.001) increase in the strain to failure and a significant (p<0.001) decrease in Young's modulus in comparison to Palacosreg R, whereas ultimate tensile strength remained unchanged. When the monomer OMA was incorporated, low concentrations of OMA provided a significant increase in tensile strength and elastic modulus without impairing the strain to failure. The results demonstrate that the experimental cements based on DMAO and OMA have excellent promise for use as orthopaedic and/or dental grouting materials.  相似文献   

3.
This work involved determining the fracture toughness, KIc (in MPa(square root)m) (using rectangular compact tension specimens) and impact strength, IS (in kJ/m2) (Charpy type specimens) of Surgical Simplex P and three variants of Palacos R acrylic bone cements. The best fit to these results yielded a power relationship KIc = 0.795(IS)0.59. The usefulness of this relationship is detailed, especially for the purpose of performing quality control checks on bone cements.  相似文献   

4.
Porous-free, two-solution bone cements have been developed in our laboratory as an alternative to commercial powder/liquid formulations. Each pair of solutions consist of poly(methyl methacrylate) (PMMA) powder dissolved in methyl methacrylate (MMA) monomer, with benzoyl peroxide (BPO) added to one solution as the initiator and N,N-dimethyl-p-toluidine (DMPT) added to the other as the activator. When mixed, the solutions polymerize via a free radical reaction, which is governed by the concentrations of initiator and activator and their molar stoichiometry. Previous work by the authors has demonstrated that these two-solution cement compositions are comparable to Simplex P bone cement in polymerization exotherm, setting time, and flexural mechanical properties. This study was designed to evaluate the effect of BPO and DMPT concentrations, along with their molar ratio, on the fracture toughness, fatigue strength, and residual monomer content of the experimental compositions. The results showed that fracture toughness and fatigue strength for the solution cements were comparable to Simplex P and were not significantly affected by the BPO concentration or the BPO:DMPT molar ratio; however, the highest DMPT concentration yielded significantly lower values for both variables. Residual monomer content was significantly affected by both the individual concentrations of BPO and DMPT and their molar ratios. The two-solution cements had significantly higher residual monomer contents versus Simplex P; however, this can be attributed to their higher initial monomer concentration rather than a lower degree of conversion.  相似文献   

5.
The fact that the composition of acrylic bone cement, as used in cemented primary arthroplasties, is not optimal has been highlighted in the literature. For example: (i) deleterious effects of the radiopacifier (BaSO4 or ZrO2 particles in the powder) have been reported; (ii) there is an indication that pre-polymerized poly(methylmethacrylate) (PMMA) beads in the powder may be dispensed with; and (iii) there is a strong consensus that the accelerator commonly used, N,N-dimethyl-p-toluidine (DMPT), is toxic and has many other undesirable properties. At the same time, the effectiveness of drugs that contain a strontium compound in treating the effects of osteoporosis has been explained in terms of the role of strontium in bone formation and resorption. This indicates that strontium compounds may also have desirable effects on osseointegration of arthroplasties. The present study is a detailed evaluation of 24 acrylic bone cement formulations comprising different relative amounts of BaSO4, strontia (as an alternative radiopacifier), pre-polymerized PMMA beads and DMPT. A large number of properties of the curing and cured cement were determined, including setting time, polymerization rate, fracture toughness and fatigue life. The focus was on the radiopacifier, with the finding being that many properties of formulations that contained strontia were about the same or better than those for cements that contained BaSO4. Thus, further developmental work on strontia-containing acrylic bone cements is justified, with a view to making them candidates for use in cemented primary arthroplasties.  相似文献   

6.
Lewis G  Janna S 《Biomaterials》2003,24(23):4315-4321
Constant-amplitude uniaxial tension-compression fatigue tests were conducted on specimens fabricated from 12 sets of acrylic bone cements, covering cement formulations with three different viscosities (so-called "high-", "medium-" and "low-viscosity" varieties), two different methods of mixing the cement constituents (so-called "hand-" and "vacuum-mixed" methods) and two test specimen shapes (rectangular-cross-sectioned or "flat" and circular-cross-sectioned or "round"). The test results-namely, the number of fatigue stress cycles, N(f)-were analyzed using the linearized transformation of the three-parameter Weibull relationship, allowing the values of the Weibull mean, N(WM), to be determined for each set. Values ranged from 14,300 to 1,284,331 for the round specimen sets and from 2898 to 72,960 for the flat specimen sets. Statistical analysis of the ln N(f) data, together with an examination of the N(WM) values, showed that, for any combination of cement formulation and mixing method, round specimens had significantly longer fatigue lives compared to flat ones. These results are explained in terms of two factors. The first is the smaller surface area of the waisted zone in the round specimens compared to that in the flat specimens (nominal value of 157mm(2) versus nominal value of 185mm(2)), leading to the possibility of fewer crack initiation sites on the round specimens compared to the flat ones. Secondly, it is postulated that the crystallinity of the round specimens was higher than that of the flat ones, a consequence of the significantly lower measured residual liquid monomer contents of the former compared to the latter (3.40+/-1.28wt%/wt compared to 3.81+/-1.48wt%/wt). The significance of the present finding is that it indicates that, for a set of bone cement formulation and experimental conditions, discriminating fatigue test results are more likely to be obtained if flat, rather than round, test specimens are used.  相似文献   

7.
The effect that three different radiopacifying agents, two of them inorganic (BaSO4, ZrO2) and one organic (an iodine containing monomer, IHQM) have on the static and dynamic mechanical properties of acrylic bone cements was studied. Compressive and tensile strength, fracture toughness and fatigue crack propagation were evaluated. The effect of the inorganic fillers depends on their size and morphology. In relation to the radiolucent cement, the addition of zirconium dioxide improved significantly the tensile strength, the fracture toughness and the fatigue crack propagation resistance. In contrast, the addition of barium sulphate produced a decrease of the tensile strength, but did not affect the fracture toughness and improved the crack propagation resistance. When the iodine containing monomer was used, although the tensile strength and the fracture toughness increased, the fatigue crack propagation resistance remained as low as it was for the radiolucent cement.  相似文献   

8.
The composition and viscosity of an acrylic bone cement have both been identified in the literature as being parameters that affect the mechanical properties of the material and, by extension, the in vivo longevity of cemented arthroplasties. The objective of the present study was to determine the relative influence of these parameters on a key cement mechanical property; namely, its fracture toughness. Two sets of cements were selected purposefully to allow the study objective to be achieved. Thus, one set comprised two cements with very similar compositions but very different viscosities (Cemex RX, a medium-viscosity brand, and Cemex Isoplastic, a high-viscosity brand) while the other set comprised two cements with similar viscosities but with many differences in composition (Cemex Isoplastic and CMW 1). Values of the fracture toughness (as determined using chevron-notched short rod specimens) [K(ISR)] obtained for Cemex RX and Cemex Isoplastic were 1.83 +/- 0.12 and 1.85 +/- 0.12 MPa square root(m), respectively, with the difference not being statistically significant. The K(ISR) values obtained for Cemex Isoplastic and CMW 1 were 1.85 +/- 0.12 and 1.64 +/- 0.18 MPa square root(m), respectively, with the difference being statistically significant. Thus, the influence of cement composition on its K(ISR) is more marked relative to the influence of cement viscosity. Explanations of this finding are offered, together with comments on the implications of the results for the in vivo longevity of cemented arthroplasties.  相似文献   

9.
The goal of the present work was to investigate the influence of the viscosity classification of an acrylic bone cement on its in vitro fatigue performance, as determined in fully-reversed tension-compression (+/-15 MPa) fatigue tests. The test matrix comprised six commercially available bone cements [Orthoset1, (OS1), Orthoset(R)3 (OS3), CemexRX (CRX), Cemex XL (CXL), Palacos R (PR) and Osteopal (OP)], two methods of mixing the cement constituents (hand-mixing and vacuum-mixing), two methods of fabricating the test specimens (direct molding and molding followed by machining), two specimen cross-sectional shapes (rectangular or "flat" and circular or "round"), and four test frequencies (1, 2, 5, and 10 Hz). In total, 185 specimens, distributed among 20 sets, were tested. The test results (number of fatigue stress cycles, N_f) were processed using the linearized transformation of the three-parameter Weibull distribution, whence estimates of the Weibull mean, N_[WM], were obtained. Statistical analysis of the ln N_f results (Mann-Whitney test; alpha<0.05) and a comparison of the N_[WM] estimates for specimen sets in which the formulations have essentially the same composition but different viscosity classification (namely, OS1 versus OS3, CRX versus CXL, and PR versus OP) showed that, in the majority of the comparisons carried out, the viscosity classification of a bone cement does not exert a significant influence on its in vitro fatigue performance.  相似文献   

10.
Lewis G  Janna SI 《Biomaterials》2004,25(7-8):1415-1420
During a cemented arthroplasty, the prepared polymerizing dough of acrylic bone cement is subjected to pressurization in a number of ways; first, during delivery into the freshly prepared bone bed, second, during packing in that bed (either digitally or with the aid of a mechanical device), and, third, during the insertion of the prosthesis. Only a few studies have reported on the influence of the level of pressurization experienced during these events (which, depending on the cementing technique used, has been put at between 8 and 273 kPa) on various properties of the cement. That was the focus of the present study, in which the fully reversed tension-compression (+/-15 MPa; 5 Hz) fatigue lives (expressed as number of cycles to fracture, N(f)) of rectangular cross-sectioned "dog-bone" specimens (Type V, per ASTM D 638) fabricated from Cemex XL cement, at pressure applied continuously to the cement dough during curing in the specimen mold, p=75,150, and 300 kPa, were determined. The N(f) results were analyzed using the linearized transformation of the three-parameter Weibull relationship to obtain estimates of the Weibull mean, N(WM), which was taken to be the index of fatigue performance of the specimen set. Over the range of p studied, N(WM) increased as p increased (for example, from 329,118 cycles when p was 75 kPa to 388,496 cycles when p was 300 kPa); however, the increase was not significant over any pair of p increment steps (Mann-Whitney U-test; alpha<0.05).  相似文献   

11.
Lewis G  Janna S  Carroll M 《Biomaterials》2003,24(6):1111-1117
The goal of the present work was to test the hypothesis that test frequency, f, does not have a statistically significant effect on the in vitro fatigue life of an acrylic bone cement. Uniaxial constant-amplitude tension-compression fatigue tests were conducted on 12 sets of cements, covering three formulations with three very different viscosities, two different methods of mixing the cement constituents, and two values of f (1 and 10 Hz). The test results (number of fatigue stress cycles, N(f)) were analyzed using the linearized form of the three-parameter Weibull equation, allowing the values of the Weibull mean (N(WM)) to be determined for each set. Statistical analysis of the lnN(f) data, together with an examination of the N(WM) estimates, showed support for the hypothesis over the range of f used. The principal use and explanation of the present finding are presented.  相似文献   

12.
Acrylic (polymethylmethacrylate or PMMA) bone cement was modified by the addition of high-strength zirconia fibers with average lengths of 200 microm and diameters of 15 microm or 30 microm. A novel emulsion polymerization process was developed to encapsulate individual fibers in PMMA. Improvements in tensile and compressive properties as well as in fracture toughness were investigated upon incorporation of uncoated and acrylic coated zirconia fibers. Bone cements were reinforced with 2% by volume of the 15 microm diameter and 5% by volume of the 30 microm fibers. Results indicate that elastic modulus and ultimate strength of bone cements reinforced with zirconia fibers were higher than controls, being the largest for cements reinforced with 30 microm diameter fibers. The fracture toughness of the cement increased by 23% and 41% by the addition of 15 microm and 30 microm fibers, respectively. Coating of individual zirconia fibers did not result in improved material properties of bone cements. The use of uncoated or acrylic coated 30 microm fibers is recommended based on the significant increases in ultimate strength and fracture toughness of the cements.  相似文献   

13.
Zinc phosphate cements are commonly supplied as two components, powder and liquid, and the proportions of the constituents are determined by operator experience. A capsulated system which is mechanically mixed has been marketed and this study investigated the performance of the encapsulated cement system. The mean fracture strength, standard deviation and associated Weibull Moduli (m) of encapsulated cements were determined by compressive fracturing 20 cement specimens filled directly from the mixing syringe or from narrower cement tubes. Pore distribution within the cylindrical specimens was determined using image analysis to assess the influence of the method of mould filling with the cement. The strength data showed variation in magnitude and consistency ranging from 44.6+/-13.7 MPa (m = 3.18+/-0.71) for cements filled directly from the syringe to 61.0+/-7.8 MPa (m = 8.35+/-1.87) for cements filled from cement tubes. Larger pores were found in specimens consolidated directly from the cement syringe. Mechanical mixing of the encapsulated cement resulted in air entrapment in the cement mix which manifested itself as large pores (over 200 microm diameter) within the cylindrical specimens. The smaller orifice of the cement tube compared with the syringe was considered to be responsible for eliminating the majority of the air entrapped in the cement mass during mixing. Whilst mechanical mixing of encapsulated cements is quicker and more convenient, the encapsulated specimens consolidated according to the manufacturers instructions from the syringe offered no significant advantage in terms of reliability or strength over hand-mixed cements in this investigation.  相似文献   

14.
In all acrylic bone cement formulations in clinical use today, radiopacity is provided by micron-sized particles (typical mean diameter of between about 1 and 2 microm) of either BaSO(4) or ZrO(2). However, a number of research reports have highlighted the fact that these particles have deleterious effects on various properties of the cured cement. Thus, there is interest in alternative radiopacifiers. The present study focuses on one such alternative. Specifically, a cement that contains covalently bound iodine in the powder (herein designated the I-cement) was compared with a commercially available cement of comparable composition (C-ment3), in which radiopacity is provided by BaSO(4) particles (this cement is herein designated the B-cement), on the basis of the strength (sigma(b)), modulus (E(b)), and work-to-fracture (U(b)), under four-point bending, plane-strain fracture toughness (K(IC)), Weibull mean fatigue life, N(WM) (fatigue conditions: +/-15 MPa; 2 Hz), activation energy (Q), and frequency factor (ln Z) for the cement polymerization process (both determined by using differential scanning calorimetry at heating rates of 5, 10, 15, and 20 K min(-1)), and the diffusion coefficient for the absorption of phosphate-buffered saline at 37 degrees C (D). For the B-cement, the values of sigma(b), E(b), U(b), K(IC), N(WM), Q, ln Z, and D were 53 +/- 3 MPa, 3000 +/- 120 MPa, 108 +/- 15 kJ m(-3), 1.67 +/- 0.02 MPa check mark m, 7197 cycles, 243 +/- 17 kJ mol(-1), 87 +/- 6, and (3.15 +/- 0.94) x 10(-12) m(2) s(-1), respectively. For the I-cement, the corresponding values were 58 +/- 5 MPa, 2790 +/- 140 MPa, 118 +/- 45 kJ m(-3), 1.73 +/- 0.11 MPa check mark m, 5520 cycles, 267 +/- 19 kJ mol(-1), 95 +/- 9, and (3.83 +/- 0.25) x 10(-12) m(2) s(-1). For each of the properties of the fully cured cement, except for the rate constant of the polymerization reaction, at 37 degrees C (k'), as estimated from the Q and ln Z results, there is no statistically significant difference between the two cements. k' for the I-cement was about a third that for the B-cement, suggesting that the former cement has a higher thermal stability. The influence of various characteristics of the starting powder (mean particle size, particle size distribution, and morphology) on the properties of the cured cements appears to be complex. When all the present results are considered, there is a clear indication that the I-cement is a viable candidate cement for use in cemented arthroplasties in place of the B-cement.  相似文献   

15.
Lewis G  Sadhasivini A 《Biomaterials》2004,25(18):4425-4432
In the literature on fatigue testing of acrylic bone cements, data sets of various sizes have been used in different test series for the same cement formulation. There are two important consequences of this situation. First, it means that some test series last much longer than others, with all the implications for the cost of testing. Second, it makes drawing conclusions about the fatigue performance of a cement, based on the results of different literature series, a problematic issue. Clearly then, a recommendation as to what should be the minimum number of test specimens to use that would allow for confidence in the results of the statistical treatment of the test results (Gmin) would be desirable. In the present work, a method that could be used to culminate in such a recommendation is described. This method involves (i) obtaining experimental fatigue test results and (ii) analyzing those results using the Weibull probability distribution function and other statistical methods. This methodology is illustrated using fatigue life results obtained from uniaxial tension-compression fatigue tests on specimens fabricated from the polymerizing dough of one commercially available acrylic bone cement. For a tolerable error of 5%, we estimated Gmin to be either 7 (if the fatigue life results are treated using the two-parameter Weibull distribution function) or 11 (if the fatigue life results are treated using the three-parameter Weibull distribution function). To be on the conservative side, we therefore recommend that Gmin be 11. Three key limitations of the methodology presented here are discussed.  相似文献   

16.
Lewis G  Janna S  Bhattaram A 《Biomaterials》2005,26(20):4317-4325
Two variants of antibiotic powder-loaded acrylic bone cements (APLBCs) are widely used in primary total joint replacements. In the United States, the antibiotic is manually blended with the powder of the cement at the start of the procedure, while, in Europe, pre-packaged commercially-available APLBCs (in which the blending is carried out using an industrial mixer) are used. Our objective was to investigate the influence of the method of blending gentamicin sulphate with the powder of the Cemex XL formulation on a wide collection of properties of the cured cement. The blending methods used were manual mixing (the MANUAL Set), use of a small-scale, easy-to-use, commercially-available mechanical powder mixer, OmoMix 1 (the MECHANICAL Set), and use of a large-scale industrial mixer (Cemex Genta) [the INDUSTRIAL Set]. In the MECHANICAL and MANUAL Sets, the blending time was 3 min. In preparing the test specimens for each set, the blended powder used contained 4.22 wt% of the gentamicin powder. The properties determined were the strength, modulus, and work-to-fracture (all obtained under four-point bending), plane-strain fracture toughness, Weibull mean fatigue life (fatigue conditions: +/-15 MPa; 2 Hz), activation energy and frequency factor for the cement polymerization process (both determined using differential scanning calorimetry, at heating rates of 5, 10, 15, and 20 Kmin(-1)), the diffusion coefficient for the absorption of phosphate buffered saline, PBS, at 37 degrees C, and the rate of elution of the gentamicin into PBS, at 37 degrees C (E). Also determined were the particle size, particle size distribution, and morphology of the blended powders and of the gentamicin. For each of the cured cement properties (except for E), there is no statistically significant difference between the means for the 3 cements, a finding that parallels the observation that there are no significant differences in either the mean particle size or the morphology of the blended cement powders. Notwithstanding these results, it is suggested that when the powder mixture is blended in the operating room, using the OmoMix 1 is more likely to produce a more consistent and reproducible mixture than when manual mixing is used.  相似文献   

17.
Poly(methyl methacrylate) (PMMA) bone cements have a long and successful history of use for implant fixation, but suffer from a relatively low fracture and fatigue resistance which can result in failure of the cement and the implant. Fiber or particulate reinforcement has been used to improve mechanical properties, but typically at the expense of the pre-cured cement viscosity, which is critical for successful integration with peri-implant bone tissue. Therefore, the objective of this study was to investigate the effects of zirconia fiber reinforcement on the fatigue life of acrylic bone cements while maintaining a relatively low pre-cured cement viscosity. Sintered straight or variable diameter fibers (VDFs) were added to a PMMA cement and tested in fully reversed uniaxial fatigue until failure. The mean fatigue life of cements reinforced with 15 and 20 vol% straight zirconia fibers was significantly increased by ~40-fold, on average, compared to a commercial benchmark (Osteobond?) and cements reinforced with 0–10 vol% straight zirconia fibers. The mean fatigue life of a cement reinforced with 10 vol% VDFs was an order of magnitude greater than the same cement reinforced with 10 vol% straight fibers. The time-dependent viscosity of cements reinforced with 10 and 15 vol% straight fibers was comparable to the commercial benchmark during curing. Therefore, the addition of relatively small amounts of straight and variable diameter zirconia fibers was able to substantially improve the fatigue resistance of acrylic bone cement while exhibiting similar handling characteristics compared to current commercial products.  相似文献   

18.
Two different methods have been used to fatigue test four bone cements. Each method has been used previously, but the results have not been compared. The ISO 527-based method tests a minimum of 10 samples over a single stress range in tension only and uses Weibull analysis to calculate the median number of cycles to failure and the Weibull modulus. The ASTM F2118 test regime uses fewer specimens at various stress levels tested in fully reversed tension–compression, and generates a stress vs. number of cycles to failure (S–N) or Wöhler curve. Data from specimens with pores greater than 1 mm across is rejected. The ISO 527-based test while quicker to perform, provides only tensile fatigue data, but the material tested includes pores, thus the cement is closer to cement in clinical application. The ASTM regime uses tension and compression loading and multiple stress levels, thus is closer to physiological loading, but excludes specimens with defects obviously greater than 1 mm, so is less representative of cement in vivo. The fatigue lives between the cements were up to a factor 15 different for the single stress level tension only tests, while they were only a factor of 2 different in the fully reversed tension–compression testing. The ISO 527-based results are more sensitive to surface flaws, thus the differences found using ASTM F2118 are more indicative of differences in the fatigue lives. However, ISO 527-based tests are quicker, so are useful for initial screening.  相似文献   

19.
The purpose of this study was to characterize a poly(methyl methacrylate) bone cement that was loaded with the antibiotic gentamicin sulphate (GS) and lactose, which served to modulate the release of GS from cement specimens. The release of GS when the cement specimens were immersed in phosphate-buffered saline at 37 °C was determined spectrophotometrically. The microstructure, porosity, density, tensile properties and flexural properties of the cements were determined before and after release of GS. A kinetics model of the release of GS from the cement that involved a coupled mechanism based on dissolution/diffusion processes and an initial burst effect was proposed. Dissolution assay results showed that drug elution was controlled by a diffusion mechanism which can be modulated by lactose addition. Density values and mechanical properties (tensile strength, flexural strength, elastic modulus and fracture toughness) were reduced by the increased porosity resulting from lactose addition, but maintained acceptable values for the structural functions of bone cement. The present results suggest that lactose-modified, gentamicin-loaded acrylic bone cements are potential candidates for use in various orthopaedic and dental applications.  相似文献   

20.
An iodinated quaternary amine dimethacrylate monomer was synthesized and incorporated as a comonomer in acrylic bone cements. Bone cement is used in orthopaedic surgery and imparting antibacterial properties to the cement can be beneficial in the lowering of bacterial infection post surgery. PMMA based bone cements were modified by copolymerising the monomer methylmethacrylate (MMA) with a quaternary amine dimethacrylate by using the redox initiator activator system as used for curing commercial bone cements. The cements were prepared using the commercial PMMA bone cement CMW and the liquid component was modified with the amine to render antimicrobial properties to the cement. The physical, mechanical, and antimicrobial properties of the modified cements were evaluated; in addition, the viability of the cement to function as a orthopaedic cement was also established, especially with an advantage of it being radiopaque, due to the inclusion of the iodine containing quaternary amine. The cytotoxicity of the modified cements were tested using a human cell model and the results indicated that the cells remained metabolically active and proliferated when placed in direct contact with the experimental cement specimens. The cements and their eluants did not evoke any cytotoxic response.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号