首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Background

Aseptic loosening after total hip arthroplasty is likely related to nicotine ingestion. However, aseptic loosening as a direct consequence of smoking habits has not been described with regard to proximal mega-prosthetic femoral replacement. The aim of the present study was to evaluate the association between nicotine consumption and aseptic loosening rates after proximal mega-prosthetic femoral replacement.

Materials and methods

A consecutive series of patients who received mega-prosthetic replacement of the proximal femur at our hospital between 2005 and 2015 were included. Their files were reviewed and evaluated for the influence of smoking on aseptic loosening rates. All living patients were invited to complete a functional follow-up assessment at our clinic.

Results

Twenty-six patients with 27 prostheses were included. Five patients were active smokers, and 21 patients were non-smokers. Aseptic loosening was observed in three patients in the smoking group, whereas none of the non-smokers developed aseptic loosening. Fisher’s exact test showed a relationship between nicotine consumption and aseptic loosening of the prostheses (p = 0.003).

Conclusions

Smoking increases the likelihood of aseptic loosening after proximal mega-prosthetic femoral replacement.

Level of evidence

Level 4 according to Oxford Centre of Evidence-Based Medicine 2011.
  相似文献   

2.

Objective

Treatment of displaced periprosthetic acetabular fractures in elderly patients. The goal is to stabilize an acetabular fracture independent of the fracture pattern, by inserting the custom-made roof-reinforcement plate and starting early postoperative full weight-bearing mobilization.

Indications

Acetabular fracture with or without previous hemi- or total hip arthroplasty.

Contraindications

Non-displaced acetabular fractures.

Surgical technique

Watson-Jones approach to provide accessibility to the anterior and supraacetabular part of the iliac bone. Angle-stable positioning of the roof-reinforcement plate without any fracture reduction. Cementing a polyethylene cup into the metal plate and restoring prosthetic femoral components.

Postoperative management

Full weight-bearing mobilization within the first 10 days after surgery. In cases of two column fractures, partial weight-bearing is recommended.

Results

Of 7 patients with periprosthetic acetabular fracture, 5 were available for follow-up at 3, 6, 6, 15, and 24 months postoperatively. No complications were recognized and all fractures showed bony consolidation. Early postoperative mobilization was started within the first 10 days. All patients except one reached their preinjury mobility level. This individual and novel implant is custom made for displaced acetabular and periprosthetic fractures in patients with osteopenic bone. It provides a hopeful benefit due to early full weight-bearing mobilization within the first 10 days after surgery.

Limitations

In case of largely destroyed supraacetabular bone or two-column fractures according to Letournel additional synthesis via an anterior approach might be necessary. In these cases partial weight bearing is recommended.
  相似文献   

3.

Background

Posterior glenoid bone loss in primary glenohumeral osteoarthritis (GHOA) presents a challenge when considering replacement surgery. Results with anatomic shoulder arthroplasty are unpredictable due to posterior humeral instability and limited bone stock for glenoid component fixation.

Objectives

To describe and evaluate the results of a “shaped” humeral head autograft with reverse shoulder arthroplasty (RSA) for the treatment of primary GHOA with significant posterior glenoid bone loss and an intact, functional rotator cuff.

Materials and methods

We retrospectively reviewed 29 “shaped” humeral head autografts with RSA for the treatment of GHOA with B2 (= 16), B3 (= 10), or C (= 3) glenoid morphology based on the Walch classification system. Average glenoid retroversion was 32.3°. Humeral head autografts were “shaped” to match each patient’s individual glenoid morphology. Functional outcome scores, range of motion, strength, and radiographic outcomes were evaluated.

Results

At average follow-up of 34.6 months (range 23.7–88.9 months), significant improvements were seen in all functional outcome scores, ranges of motion, and strength (p <0.01). No recurrent instability or glenoid fixation failure occurred. Two complications (1 superficial and 1 deep infection) in 2 patients were identified. All autografts incorporated without radiographic evidence of loosening. Scapular notching was observed in 8 shoulders. No negative correlations were identified with glenoid morphology.

Conclusions

“Shaped” humeral head autograft with RSA for the treatment of primary GHOA with significant posterior glenoid bone loss is associated with excellent clinical and radiographic outcomes and a low complication profile at short- to mid-term follow-up.
  相似文献   

4.

Purpose

To stratify stage IIB (pT4a PN0) colorectal cancer in terms of histopathologic findings.

Methods

We reviewed the medical records of 80 patients who underwent surgery for stage IIB colorectal cancer. The disease-free survival (DFS) and overall survival (OS) rates were evaluated and correlated with the presence or absence of “Tumor Necrosis”, “Crohn’s-like lymphoid reaction”, and “Perineural Invasion”.

Results

Patients with “Tumor Necrosis” had significantly lower DFS rates (p < 0.0001), those with “Crohn’s-like lymphoid reaction” had significantly higher DFS rates (p = 0.037), and those with “Perineural Invasion” had significantly lower DFS rates (p < 0.0001). Patients with “Tumor Necrosis” had significantly lower OS rates (p = 0.016), those with “Crohn’s-like lymphoid reaction” had significantly higher OS rates (p = 0.022), and those with “Perineural Invasion” had significantly lower OS rates (p = 0.003).

Conclusions

Since stage IIB colorectal cancers accompanied by the pathological findings of “Tumor Necrosis” and “Perineural Invasion”, but with the absence of “Crohn’s-like lymphoid reaction” carried a poor prognosis, the efficacy of adjuvant chemoradiation must be considered for these patients.
  相似文献   

5.

Purpose

Outcome data beyond 11 years of follow-up is not available for the third-generation Zweymüller femoral stem in combination with a polyethylene bearing. We report ten to 15-year results with this total hip arthroplasty (THA) combination in a young population.

Methods

A retrospective, observational, non-randomised, single-centre, clinical observational study was conducted in which 311 primary THAs were performed in 276 patients between 1996 and 2000 using a third-generation Zweymüller stem. The mean age of the patients at operation was 47.4 years (range 18–77 years).

Results

Stem survival for any reason was 93.5 % after ten years and 89.6 % after 13 years, and the probability of aseptic stem loosening was 98.7 % at both ten and 13 years. The occurrence of femoral radiolucent lines was low, at just 17.2 %. Minor femoral osteolysis was identified in 30 % of patients and was attributed to polyethylene liner wear. Clinical and patient satisfaction outcomes were in line with previous investigations, and the rate of adverse events was low.

Conclusions

The third-generation Zweymüller stem shows good radiographic and clinical results and good longevity, including in the younger osteoarthritic patient. The use of low-wear bearings may further reduce the rate of osteolysis and wear-related revision in young and active patients.
  相似文献   

6.

Introduction

The SOFCOT symposium (2005) on periprosthetic fractures of the femur (PFFs) highlighted a high rate of dislocation (15.6% at 6 months) after change of prosthesis. So far, no study has ever proved the benefit of dual-mobility articulation during PFFs revisions. We conducted a comparative study on two prospective cohorts in order to (1) assess the influence of systematic acetabular revision in favor of a double mobility on dislocation rate (2) and in order to evaluate the rate of morbidity associated with this extra surgical procedure.

Hypothesis

A systematic replacement of the cup in favor of a dual-mobility articulation enables to reduce the dislocation rate in PFFs revisions without increasing morbidity.

Methodology

We compared two prospective multicenter cohorts over a year (2005 and 2015) using the same methodology. Any fracture around hip prosthesis which occurred 3 months at least after surgery was included. Data collection was clinical and radiological on preoperative, intraoperative and 6 months after surgery. The 2015 “bipolar” group (n = 24) included patients who had a bipolar revision (both femoral and dual-mobility articulation). The 2005 “unipolar” group (n = 25) included patients who had only a femoral implant revision. Patients were comparable by age (p = 0.36), sex (p = 0.91), ASA score (p = 0.36), history of prosthetic revision (p = 1.00), Katz score (p = 0.50) and the type of fracture according to the Vancouver classification (p = 0.55).

Results

There was a 4% rate of dislocation in the “bipolar group” while there was 21% rate of dislocation in the “unipolar group” (8% of recurrent dislocation) (p = 0.19). The rate of all-cause complications 6 months after surgery was not significantly different (p = 0.07): 12.5% in the 2015 “bipolar” cohort (one dislocation, one non-symptomatic cup migration and one pseudarthrosis of the major trochanter) versus 35% in the “unipolar” cohort (5 dislocations, 1 major trochanter fracture and 1 femur pseudarthrosis, 1 secondary displacement associated with a superficial infection). The surgical revision after 6 months was not significantly different (1/23 or 4% vs. 4/25 or 16%, p = 0.35).

Conclusion

We confirm the low rate of dislocations after fitting a dual-mobility cup in case of revision of the femoral side in case of periprosthetic femoral fracture, as well as the need for additional cases to be carried out upon further studies to significantly confirm the interest of preventing instability after femoral revision.
  相似文献   

7.

Purpose

The aim of this study was to evaluate clinical and radiographic findings of stage 3 or lower osteonecrosis of the femoral head (ONFH) with intact acetabular cartilage in patients treated with bipolar hemiarthroplasty (BHA).

Methods

A total of 79 hips that underwent BHA for ONFH were included in this study. The average observation period was 7.6 years. Clinical results were evaluated using the Harris hip score. We performed radiographic analysis to assess the migration of the outer cup, the permanent image around the outer cup, and loosening of the stem.

Results

The total Harris hip score improved from 50 points before surgery to 92 points at final follow-up, while pain improved from 14 points to 36 points. Flexion improved from 94° to 120° and abduction from 27° to 37°. One patient on dialysis showed progress in terms of inward migration, and revision surgery was performed on the patient 14 years after the original surgery.

Conclusions

Midterm performance of BHA for stage 3 or lower ONFH at our hospital was good.
  相似文献   

8.

Study design

We evaluated the trajectory and the entry points of anterior transpedicular screws (ATPS) in the cervicothoracic junction (CTJ).

Objective

This study aimed at investigating the feasibility of ATPS fixation in the CTJ.

Summary of background data

Application of an ATPS in the lower cervical spine has been reported; however, there were no reports exploring the feasibility of anterior transpedicular screw fixation in the CTJ.

Methods

CT scans were performed in 50 cases and multiplanar reformation was used to measure the related parameters on pedicle axis view at C6–T2. Transverse pedicle angle, outer pedicle width, pedicle axis length, distance transverse intersection point (DtIP), sagittal pedicle angle, anterior vertebral body height, outer pedicle height, and distance sagittal intersection point (DsIP) were measured. The prozone of CTJ was divided into three different regions, which were named as the “manubrium region”, the region “above” and “below” the manubrium. The distribution of the trajectory of sagittal pedicle axes was recorded in the three regions and the related data were statistically analyzed.

Results

There was no statistical difference in gender (P > 0.05). The transverse pedicle angle decreased from C6 (46.77° ± 2.72°) to T2 (20.62° ± 5.04°). DtIP increased from C6 to T2. DsIP was an average of 7.17 mm. The sagittal pedicle axis lines of the C6 and C7 were located in the region above the manubrium. T1 was mainly in the manubrium region followed by the region above the manubrium. T2 was mainly located in the manubrium region followed by the region below the manubrium.

Conclusion

Implantation of ATPS at C6, C7, and some T1 is feasible through the low anterior cervical approach, while it is almost impossible to approach T2 that way.
  相似文献   

9.

Background

New patients come more and more often over the internet; therefore internet marketing plays an increasingly important role.

Question

How can physicians build an effective internet marketing strategy and avoid complications?

Method

Selection and authorization of a reputable agency.

Results

New customer acquisition through high visibility in the internet, at the same time increasing the image and awareness.

Conclusions

In the overall “marketing mix” internet marketing has become indispensable to physicians who want to be successful. Those who are well positioned in Google are well known by their target audience and thus receive a higher response.
  相似文献   

10.

Purpose

Femur deformities can make stem fixation difficult in total hip arthroplasty (THA). We report the clinical results of cementless THA using a press-fit stem in patients who had previously undergone femoral osteotomy for hip dysplasia.

Methods

The subjects included 66 hips in 64 patients, with the mean follow-up period of 7.3 years. THA was performed at a mean period of 17.1 years after intertrochanteric femoral osteotomy. Valgus osteotomy was performed in 42 hips, and varus osteotomy in 24. Clinical results were evaluated by using the Merle d’Aubigne-Postel score. Implant survival was determined with revision as the end point, and any related complications were investigated.

Results

The Merle d’Aubigne-Postel score improved from 9.4 to 16.1 at the final follow-up, without any implant loosening. However, periprosthetic femoral fractures were observed in four hips (6.0 %), one intra-operatively and three within three weeks after THA. Among these cases, three hips previously had varus osteotomy (12.5 %) and one hip had valgus osteotomy (2.3 %). Two hips were revised with full porous stems and circumferential wiring. The five and ten year cumulative survivorship rates were 97 % (range, 88.8–99.3 %) and 97 % (88.8–99.3 %), respectively.

Conclusions

Although the use of a press-fit cementless stem yielded acceptable results in most of the patients, perioperative femoral fracture was a major complication especially in the patients previously treated with intertrochanteric varus osteotomy. Careful planning and implant selection could be emphasized for these cases.
  相似文献   

11.

Background and purpose

Objectives were (1) to evaluate results after cerclage wiring technique for femoral primary and periprosthetic fracture (PPF); (2) to report the incidence of complications and their treatment; (3) to analyze possible prognostic factors.

Patients and methods

We analyzed 54 patients treated with different techniques associated with low-contact cerclage wires for femoral fracture. Fractures were stratified according to AO, Vancouver or Rorabeck classification. Cerclage was used as an exclusive implant in four PPFs or combined with internal devices in 50 cases. Comorbidities were assessed using Charlson Comorbidity Index. The Glasgow Outcome Scale was used to compare activities of daily living pre/postoperatively.

Results

Cerclage wires with three or four spacers were used in 22 and 32 cases, respectively. Nine patients died within 6 months. Mean follow-up of the remaining 42 patients was 10.5 months. Fracture healing was achieved in 38/42 patients (71 %), with a mean time to callus formation of 57 days and to radiographic union of 3 months (1.5–9 months). Four patients had nonunion. Survival to major complications was 92 and 70 % at 1 and 2 years, respectively, significantly better in cerclage wires with three spacers than those with four spacers (p = 0.0188). No other statistical correlations were found.

Conclusion

Cerclage wiring in difficult femoral fractures offers minimally invasive reduction and fixation technique, low cost and early holding. We reinforce the concept of “reduce with cerclage cables first, then nail” for displaced long subtrochanteric fractures and support the use of cerclage wiring for challenge PPF using low-contact wires.

Level of evidence

Therapeutic study, Level IV.
  相似文献   

12.

Background

Correct positioning of a central venous catheter (CVC) tip in pediatric patients is very important. Malpositioning may lead to direct complications, such as arrhythmia and increase the risk of thrombosis, infections, valve failures or pericardial tamponade.

Objective

The aim of this review was to identify and summarize published formulae for the correct positioning of the CVC tip in children and to discuss the benefits of these formulae for the daily routine.

Material and methods

A systematic and standardized search in Medline and PubMed was performed to identify published formulae. Formulae for insertion depth of the CVC tip over the right internal jugular vein are discussed. The keywords “pediatric” or “pediatric”, “children”, “central venous catheter”, “CVC”, “central venous”, “length”, “insertion”, “optimal”, “formula”, “depth”, “correct position” and “right position”, “internal jugular vein” were used to identify the formulae.

Results

A total of 854 publications were found and 127 publications were analyzed. The publications were subsequently assessed and classified independently by a specialist in anesthesiology and a specialist in pediatrics. A total of six publications described different body height-based formulae for calculation of a CVC insertion depth. No prospective evaluation of these formulae was performed to show if it is possible to place a CVC tip at the optimal position.

Conclusion

The benefit of a formula for daily practice is very limited due to the problem of choosing the right insertion point. The recommended insertion depth should be considered as an indicator and a verification of the CVC tip position should be done using an imaging technique.
  相似文献   

13.

Objective

An arthroscopic technique for the reconstruction of the posterolateral corner combined with posterior cruciate ligament (PCL) reconstruction was developed.

Indications

Posterolateral rotational instabilities of the knee. Combined lesions of the PCL, the popliteus complex (PLT) and the posterolateral corner. Isolated PLT lesions lacking static stabilizing function.

Contraindications

Neuromuscular disorders; knee deformities or fractures; severe posterolateral soft tissue damage.

Surgical technique

Six arthroscopic portals are necessary. Using the posteromedial portal, resect dorsal septum with a shaver. Visualize the PCL, the lateral femoral condyle and the posterolateral recessus with the PLT. Dissect the popliteomeniscal fibers; retract PLT until sulcus popliteus is visualized. Drill a 6-mm tunnel anteriorly into the distal third of the sulcus popliteus. Visualize femoral footprint of the PLT and place an anatomical drill tunnel. Pull the popliteus bypass graft into the knee and fix with bioscrews. Fix the reconstructed PCL. In cases of additional LCL injury, reconstruct LCL with autologous graft.

Postoperative management

Partial weight-bearing for 6 weeks, range of motion exercises, quadriceps-strengthening exercises on postoperative day 1. Full extension allowed immediately with flexion limited to 20° for 2 weeks, to 45° for up to week 4, and to 60° up to week 6. Use a PCL brace for 3 months, running and squatting exercises allowed after 3 months.

Results

In the 35 patients treated, no technique-related complications. After 1 year, 12 patients had a mean Lysholm Score of 88.6 (± 8.7) points and a side-to-side difference in the posterior drawer test of 2.9 (± 2.2) mm (preoperative 13.3 [± 1.9] mm).

Conclusion

Low complication risk and good and excellent clinical results after arthroscopic posterolateral corner reconstruction.
  相似文献   

14.

Purpose

Unified classification system (UCS) type B1 periprosthetic femoral fractures are associated with many complications, and management decisions continue to be controversial. The purpose of this study was to evaluate outcomes of UCS type B1 periprosthetic femoral fractures treated by locking compression plating with strut allograft augmentation.

Materials and methods

We retrospectively reviewed 17 consecutive UCS type B1 periprosthetic femoral fractures treated by open reduction and internal fixation using a lateral locking compression plate supplemented with an anterior cortical strut allograft. There was one man and 16 women with an average age of 74 years (range, 57–92 years). All had a cementless hip arthroplasty, and eight of the arthroplasties were revisions.

Results

The mean duration of follow-up was 28 months (range, 12–74 months). All 17 fractures healed successfully at a mean of 20 weeks (range, 12–30 weeks). The mean post-operative Harris hip score was 86 points (range, 77–95 points). No mechanical complications such as failure of plate or screws and malalignment were noted. According to the graft-remodeling classification of Emerson et al., a partial bridging was observed in nine and a complete bridging in eight. Two patients required a removal of the plate due to irritation of the iliotibial band. No femoral stem loosening or deep infection was observed.

Conclusion

Our findings indicate that open reduction and internal fixation of UCS type B1 periprosthetic femoral fractures using a lateral locking compression plate supplemented with anterior cortical strut allograft provides adequate mechanical stability of fracture fixation and enhances the fracture healing.
  相似文献   

15.

Objective

Anatomic reconstruction of the medial patellofemoral ligament using autologous gracilis tendon in an implant-free technique on the patellar side to regain patellofemoral stability.

Indications

Recurrent dislocations, primary dislocation with high risk of recurrence, and dislocations with (osteo-)chondral flake fractures. As combined approach together with other procedures (trochleoplasty, tibial tubercle osteotomy). Revisions.

Contraindications

As an isolated procedure in patients with high degrees of trochlear dysplasia, chronic dislocation of the patella, and patellofemoral maltracking without instability.

Surgical technique

Harvesting of the gracilis tendon. Drilling of a V-shaped tunnel with a special aiming device in anatomic position on the medial side of the patella. Drilling of a femoral tunnel in anatomic position under fluoroscopic control. Passage of the graft, arthroscopic-guided tensioning, and femoral fixation with a biodegradable interference screw.

Postoperative management

Partial weight bearing (20 kg) for 1–2 weeks. No limitation in range of motion. No orthosis. Specific sports allowed after approximately 3 months.

Results

Perioperative complications associated specifically with the technique were observed in 1.0?% (7 of 729 cases). In a series of 72 consecutive cases from May 2010 to October 2010, the following were recorded after 4.0 ± 0.1 years: recurrent dislocations in 3.2?%, a Tegner activity score of 5.1 ± 1.8, and subjective satisfaction in 92?% (follow-up rate 87.5?%). No fracture of the patella was seen in any of our patients.
  相似文献   

16.

Background

The all-inside graft-link technique for anterior cruciate ligament reconstruction is performed with two cortical suspension devices with adjustable loops on both femur and tibia. This technique requires meticulous graft preparation. The aim of this study was to biomechanically test three different graft configurations resulting from differences in initial graft length.

Materials and methods

Thirty bovine digital extensor tendons were arranged in three different ways: “half-quadrupled”, “tripled” and “quadrupled”. The final graft length was 65–75 mm. The specimens were fixed vertical to the loading axis of a tensile testing machine. After a static pre-conditioning of 50 N for 5 min, a load to failure test was performed and data regarding the ultimate failure load (UFL), the stiffness and mode of failure were recorded.

Results

The evaluation of UFL showed a significant differences between group means as determined by one-way analysis of variance (F = 21.92, p = 0.002). Post hoc comparisons showed a significantly better UFL of “tripled” (p = 0.007) and “quadrupled” preparations (p = 0.014) compared to the “half-quadrupled” configuration, with no significant differences between “tripled” and “quadrupled” grafts (p = 0.061). No significant differences were found when evaluating the stiffness between the groups. Failure occurred by tendon slippage across the suture in all specimens.

Conclusion

The “quadrupled” tendon achieved the best UFL, with even the “tripled” configuration having sufficient biomechanical characteristics to withstand the loads experienced during early rehabilitation. For this reason, with a total semitendinosus length of less than 260 mm it could be better to “triple” instead of “half-quadruple” it to achieve better performance of the graft.
  相似文献   

17.

Purpose

An amino acid-containing elemental diet (ED) does not require digestion for nutritional absorption, making it a good option for patients with gastrointestinal malabsorption. We conducted a randomized trial to confirm that perioperative ED enhanced the recovery of patients undergoing laparoscopic colectomy.

Methods

Patients in the intervention arm received commercially available ED from the day prior to surgery until postoperative day (POD) 3, whereas patients in the control group received a conventional perioperative diet program. To verify the endpoints, “estimated minimum length of stay in hospital after surgery” (emLOS) was defined as the number of days necessary to reach all the five criteria; namely, “sufficient oral intake”, “sufficient pain control”, “withdrawal of intravenous alimentation”, “no abnormal findings in routine examinations”, and “no rise in fever”.

Results

A total of 102 patients were randomized, 94 of whom were analyzed (ED 45, control 49). There was no morbidity or mortality. Shorter emLOS (POD 4 vs. POD 7; p = 0.018), earlier resumption of sufficient oral intake (POD 3 vs. POD 4; p = 0.034) and faster recovery to defecation (2.2 vs. 3.1 days; p = 0.005) were observed in the ED group vs. the control group.

Conclusions

The perioperative ingestion of ED by patients undergoing laparoscopic colectomy is safe and can reduce the postoperative hospital stay by supporting the acceleration of oral intake.
  相似文献   

18.

Background

The most common modes of failure of cemented unicompartmental knee arthroplasty (UKA) designs are aseptic loosening and unexplained pain at short- to mid-term follow-up, which is likely linked to early fixation failure. Determining these modes of failure remains challenging; conventional radiographs are limited for use in assessing radiolucent lines, with only fair sensitivity and specificity for aseptic loosening.

Questions/Purposes

We sought to characterize the bone-component interface of patients with symptomatic cemented medial unicompartmental knee arthroplasty (UKA) using magnetic resonance imaging (MRI) and to determine the relationship between MRI and conventional radiographic findings.

Methods

This retrospective observational study included 55 consecutive patients with symptomatic cemented UKA. All underwent MRI with addition of multiacquisition variable-resonance image combination (MAVRIC) at an average of 17.8 ± 13.9 months after surgery. MRI studies were reviewed by two independent musculoskeletal radiologists. MRI findings at the bone-cement interface were quantified, including bone marrow edema, fibrous membrane, osteolysis, and loosening. Radiographs were reviewed for existence of radiolucent lines. Inter-rater agreement was determined using Cohen’s κ statistic.

Results

The vast majority of symptomatic UKA patients demonstrated bone marrow edema pattern (71% and 75%, respectively) and fibrous membrane (69% and 89%, respectively) at the femoral and tibial interface. Excellent and substantial inter-rater agreement was found for the femoral and tibial interface, respectively. Furthermore, MRI findings and radiolucent lines observed on conventional radiographs were poorly correlated.

Conclusion

MRI with the addition of MAVRIC sequences could be a complementary tool for assessing symptomatic UKA and for quantifying appearances at the bone-component interface. This technique showed good reproducibility of analysis of the bone-component interface after cemented UKA. Future studies are necessary to define the bone-component interface of symptomatic and asymptomatic UKA patients.
  相似文献   

19.

Background

This study aimed to translate and culturally adapt a Greek version of the Shoulder Pain and Disability Index (SPADI) questionnaire and to validate its usage in Greek patients.

Materials and methods

A forward and backward translation was performed, and the final version of the Greek questionnaire was administered to 134 outpatients (mean age 47.4 ± 14.5) with rotator cuff tear under conservative treatment. The questionnaire was re-administered 2–5 days later to assess test–retest reliability. Patients completed the Greek SPADI, the Greek version of the Quick DASH (Disability of the Arm, Shoulder and Hand Questionnaire) and the EuroQoL EQ-5D. 102 of the 134 questionnaires were considered valid.

Results

The internal consistencies of the SPADI total and its subscales measured with Cronbach’s alpha coefficient were high (0.932 for SPADI-Total, 0.899 for SPADI-Disability, 0.905 for SPADI-Pain). Intraclass correlation coefficients showed excellent test–retest reliability (0.899 for Disability, 0.902 for Pain, and 0.929 for total SPADI). A significantly high positive correlation was found between the SPADI total score and its subscales, and Quick DASH for Pain and Disability. Significant correlations were also found between SPADI scales and EQ-5D variables. There was a moderate positive correlation with the variables “self-reliance” (r = 0.66), “common activities” (r = 0.58), and “pain/discomfort” (r = 0.49), and a weaker correlation with the “mobility” variable (r = 0.20). Factor analysis (PAF method) revealed a bidimensional formation of the SPADI. Eight items (five pain/three disability) weighted the first factor by >0.5, and five disability items weighted the second factor.

Conclusions

The Greek SPADI represents a valid and reliable tool for measuring pain and disability in patients with painful shoulder disorders.

Level of evidence

Level 3.
  相似文献   

20.

Background

Anatomic shoulder arthroplasty in osteoarthritis with biconcave glenoid wear results in decreased functional results and a higher rate of early glenoid loosening.

Aim

The aim of the data analysis of the German shoulder arthroplasty register was to clarify whether reverse shoulder arthroplasty can provide better functional results and a lower complication rate than anatomic arthroplasty in osteoarthritis with biconcave glenoid wear.

Methods

The analysis included 1052 completely documented primary implanted arthroplasties with a minimum follow-up of 2 years. In 119 cases, a B2-type glenoid was present. Out of these cases, 86 were treated with an anatomic shoulder arthroplasty, and in 33 cases a reverse shoulder arthroplasty was implanted. The mean follow-up was 47.6 months.

Results

The Constant score with its subcategories, as well as the active range of movement improved significantly after anatomic and after reverse shoulder arthroplasty.

Discussion

We observed no difference in functional results between both types of arthroplasty; however, reverse arthroplasty showed a significant higher revision rate (21.2%) (3% glenoid loosening, 6% prosthetic instability) than anatomic shoulder arthroplasty (12.8%) (11.6% glenoid loosening, 1.2% prosthetic instability), whereas anatomic shoulder arthroplasty showed a higher rate of glenoid loosening. Functional and radiographic results of both types of arthroplasty are comparable with the results reported in the literature, although our analysis represents results from an implant registry (data pertaining to medical care quality).